RURD620CC, RURD620CCS
Data Sheet
January 2000
File Number
4075.2
6A, 200V Ultrafast Dual Diodes
Features
The RURD620CC and RURD620CCS are ultrafast dual
diodes with soft recovery characteristics (trr < 25ns). They
have low forward voltage drop and are silicon nitride
passivated ion-implanted epitaxial planar construction.
Ultrafast with Soft Recovery . . . . . . . . . . . . . . . . . . . <25ns
These devices are intended for use as
freewheeling/clamping diodes and rectifiers in a variety of
switching power supplies and other power switching
applications. Their low stored charge and ultrafast soft
recovery minimize ringing and electrical noise in many
power switching circuits, thus reducing power loss in the
switching transistors.
Avalanche Energy Rated
Applications
Formerly developmental type TA49037.
General Purpose
Ordering Information
Packaging
PART NUMBER
PACKAGE
Operating Temperature. . . . . . . . . . . . . . . . . . . . . . .175oC
Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200V
Planar Construction
Switching Power Supplies
Power Switching Circuits
JEDEC TO-251AA
BRAND
RURD620CC
TO-251AA
UR620C
RURD620CCS
TO-252AA
UR620C
ANODE 1
CATHODE
ANODE 2
NOTE: When ordering, use the entire part number. Add the suffix,
9A, to obtain the TO-252 variant in tape and reel, i.e.,
RURD620CCS9A.
CATHODE
(FLANGE)
Symbol
JEDEC TO-252AA
K
CATHODE
(FLANGE)
ANODE 2
ANODE 1
A1
A2
Absolute Maximum Ratings
(Per Leg) TC = 25oC Unless Otherwise Specified
RURD620CC
RURD620CCS
UNITS
Peak Repetitive Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRRM
200
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRWM
200
DC Blocking Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VR
200
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF(AV)
TC = 160oC
Repetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFRM
Square Wave, 20kHz
12
Nonrepetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
Halfwave, 1 phase, 60Hz
60
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PD
45
Avalanche Energy (See Figures 10 and 11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAVL
10
mJ
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TSTG,TJ
-65 to 175
oC
1-888-INTERSIL or 321-724-7143 | Copyright
Intersil Corporation 2000
RURD620CC, RURD620CCS
(Per Leg) TC = 25oC, Unless Otherwise Specified
Electrical Specifications
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
IF = 6A
1.0
IF = 6A, TC = 150oC
0.83
VR = 200V
100
VR = 200V, TC = 150oC
500
IF = 1A, dIF/dt = 200A/s
25
ns
IF = 6A, dIF/dt = 200A/s
30
ns
ta
IF = 6A, dIF/dt = 200A/s
13
ns
tb
IF = 6A, dIF/dt = 200A/s
6.5
ns
QRR
IF = 6A, dIF/dt = 200A/s
20
nC
VR = 10V, IF = 0A
30
pf
3.5
oC/W
VF
IR
trr
CJ
RJC
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300s, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time (See Figure 9), summation of ta + tb.
ta = Time to reach peak reverse current (See Figure 9).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RJC = Thermal resistance junction to case.
pw = Pulse width.
D = Duty cycle.
Typical Performance Curves
100
IR , REVERSE CURRENT (A)
IF, FORWARD CURRENT (A)
30
10
175oC
100oC
25oC
1
0.5
0.25
0.5
0.75
1.25
1.5
VF, FORWARD VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
175oC
10
100oC
0.1
0.01
0.001
25oC
50
100
150
200
VR , REVERSE VOLTAGE (V)
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
RURD620CC, RURD620CCS
Typical Performance Curves
(Continued)
40
20
TC = 100oC, dIF/dt = 200A/s
16
t, RECOVERY TIMES (ns)
t, RECOVERY TIMES (ns)
trr
ta
12
8
tb
4
32
trr
24
ta
16
tb
TC = 25oC, dIF/dt = 200A/s
0
0.5
0
0.5
I F, FORWARD CURRENT (A)
FIGURE 3. trr, ta AND tb CURVES vs FORWARD CURRENT
FIGURE 4. trr, ta AND tb CURVES vs FORWARD CURRENT
IF(AV), AVERAGE FORWARD CURRENT (A)
60
TC = 175oC, dIF/dt = 200A/s
t, RECOVERY TIMES (ns)
50
trr
40
ta
30
20
tb
10
0
0.5
6
5
DC
4
SQUARE WAVE
3
2
1
0
150
155
160
FIGURE 5. trr, ta AND tb CURVES vs FORWARD CURRENT
CJ , JUNCTION CAPACITANCE (pF)
40
30
20
10
50
100
150
200
VR , REVERSE VOLTAGE (V)
FIGURE 7. JUNCTION CAPACITANCE vs REVERSE VOLTAGE
170
FIGURE 6. CURRENT DERATING CURVE
50
165
TC , CASE TEMPERATURE (oC)
I F, FORWARD CURRENT (A)
I F, FORWARD CURRENT (A)
175
RURD620CC, RURD620CCS
Test Circuits and Waveforms
VGE AMPLITUDE AND
RG CONTROL dIF/dt
t1 AND t2 CONTROL IF
DUT
CURRENT
SENSE
RG
IF
VGE
IGBT
t1
VDD
dIF
trr
dt
ta
tb
0
0.25 IRM
t2
IRM
FIGURE 8. trr TEST CIRCUIT
FIGURE 9. trr WAVEFORMS AND DEFINITIONS
I = 1A
L = 20mH
R < 0.1
EAVL = 1/2LI2 [VR(AVL) /(VR(AVL) - VDD)]
Q1 = IGBT (BVCES > DUT VR(AVL))
VAVL
L
CURRENT
SENSE
R
+
VDD
IL
IL
I V
Q1
VDD
DUT
t0
FIGURE 10. AVALANCHE ENERGY TEST CIRCUIT
t1
t2
FIGURE 11. AVALANCHE CURRENT AND VOLTAGE
WAVEFORMS
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site www.intersil.com