T5 Calculations

This document provides details of the truss analysis and design for a proposed twin house construction project in Kelantan, Malaysia. It includes calculations of loads on the truss from dead load, live load, and wind load according to Malaysian standards. It then outlines the various load cases to be considered and determines the critical load case. Finally, it performs checks on individual truss members for bending capacity, axial capacity, deflection, and connection strength to ensure all components meet design requirements.

Uploaded by

MatAleng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
181 views14 pages

T5 Calculations

This document provides details of the truss analysis and design for a proposed twin house construction project in Kelantan, Malaysia. It includes calculations of loads on the truss from dead load, live load, and wind load according to Malaysian standards. It then outlines the various load cases to be considered and determines the critical load case. Finally, it performs checks on individual truss members for bending capacity, axial capacity, deflection, and connection strength to ensure all components meet design requirements.

Uploaded by

MatAleng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

COOLDEC METAL INDUSTRIES SDN. BHD.

Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

1 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

TRUSS ANALYSIS & DESIGN : LOADING (CP 3 : Chapter V : Part 1 : 1972)


1

Dead Load
Self weight

0.060

kN/m2

0.460

kN/m2

Battens

0.030

kN/m2

Services

0.120

kN/m2

Ceiling

0.130

kN/m2

Gk

0.800

kN/m2

Qk

0.250

kN/m2

Roofing

(Concrete tile)

Live Load
Imposed load

Wind Load(CP 3 : Chapter V : Part 2 : 1972)


Basic Wind Speed, Vb

35.000 m/s

5.4 Topography Factor, S1

1.000

5.6 Statistical Factor, S3

1.000

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

2 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

5.5 Ground Roughness


Where Building Class, Category & Height Above Ground (H) :
Class A:

All units of cladding, glazing and roofing and their immediate fixings
and individual members of unclad structures
[

Class B:

All buildings and structures where neither the greatest horizontal


dimension nor the greatest vertical dimension exceeds 50m(165ft)
[

Class C:

All buildings and structures whose greatest horizontal dimension or


greatest vertical dimension exceeds 50m (165 ft)
[

Category (1) :

Open country with no obstructions


[

Category (2) :

Open country with scattered windbreaks


[

Category (3) :

Country with many windbreaks; small towns; outskirts of large cities


[

Category (4) :

Surface with large and frequent obstructions e.g. city centres


[

Table 3 :

Height, H =
Take, Factor, S2 =

6.697

m
0.681

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

3 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

5.1 Design Wind Speed, VS

6.0 Dynamic Pressure,

qs

where k

Vb.S1.S2.S3

35.000

23.819

m/s

kVs2

0.613 (

0.348

kN/m2

0.61

(in S. I. Units)

1.000 X

0.681

23.819 )2 / 1000 kN/m2

7.2 Pressure Coefficients (Cpe & Cpi)


Table 8 : Pressure Coefficients Cpe for Pitch Roofs of Rectangular Clad Buildings
Building height, h

6.697 m

Building width, w

9.403 m

Building height/width

6.697

0.712

i.e

1/2

Roof Slope, f

25

Wind Angle, a

9.403

ratio, h/w

h/w

1 1/2

1.000

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

4 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

External Coefficient, Cpe

-0.450 Windward

External Coefficient, Cpe

-0.500 Leeward

Internal Coefficient, Cpi

-0.300

(Appendix E)

7.2 : Wind Load, P = (Cpe Cpi). qs


Wind Load (Windward)
Ww

{Cpe - Cpi} qs

{ -0.450

Wind Load (Leeward)


WL

Wind
(a = 0)

-0.052 kN/m2

{Cpe - Cpi} qs

{ -0.500

-0.070

-(
kN/m2

-0.300 ) } X

0.348 kN/m2

UpLift

-0.300 ) } X
Uplift

0.348 kN/m2

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

5 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

LOAD CASES(The loadings are combined into different load cases and applied with
further factors as per BS 5950 : Part 5 : 1996)
1)

1.0 Gk

0.800

kN/m2

2)

1.0 Qk

0.250

kN/m2

3)

1.4

Ww

-0.073 kN/m2

4)

1.4

WL

-0.097 kN/m2

5)

1.4

Gk

1.6 Qk

1.520

kN/m2

6)

1.2

Gk

1.2 Qk

1.2

WL

1.177

kN/m2

6a)

1.2

Gk

1.2 Qk

1.2

Ww

1.197

kN/m2

7)

1.0

Gk

1.4

Ww

0.727

kN/m2

7a)

1.0

Gk

1.4

WL

0.703

kN/m2

8)

1.0

Gk

1.0 Qk

1.050

kN/m2

CRITICAL LOAD CASES


Case

: Being the most critical load case, it is to be used as Design Load to check
axial and bending capacities.

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

6 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

DESIGN STANDARDS(BS 5950 : Part 5)


BENDING & AXIAL CHECK FOR WEB MEMBER :
Member in Bending :
Member No.
Used Section:

21

, M

0.858

kNm

T153075GAL box-up

t
t
YS

0.750

550.000

mm
Nmm-2

D
Zx

74.250

mm

5.840

Py

550.000

X 10 3
Nmm-2

mm3

B
Maximum bending stress, M/ Zx

0.858 X 10
/
-2
146.918 Nmm

5.840 X 10

Nmm-2

5.2.2.2 Maximum allowable bending stress


Po

{1.13 - 0.0019 ( D / T ) ( Ys / 280 )1/2 } Py

{1.13 - 0.0019 ( 74.250

476.505

Nmm-2 >

/ 0.750 )( 550.000 / 280)1/2 } X


146.918

Nmm-2

OK !

Member in Compression :
Member No.
Used Section:

14 ( length

1415.000 mm), F =

12.338 kN

T153075GAL

lx

10.950

X 104 mm4

rx

30.370

Ae

118.710

mm
mm2

ly

2.130

X 104 mm4

ry

13.400

mm

550.000 Nmm-2

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

7 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

6.2 Flexural Buckling


6.2.2 Maximum Slenderness, Le
Le/ry

1.000

1.0L

X 1415.0

105.597 <

180.000

PI2 X ( 200 ) X ( 10.950 X 10 4 )

OK !

13.400

6.2.3 Ultimate Load Buckling Resistance Load (Pc)


Pcs

Pe

Py x Ae

550.000

X 118.710 X 10 -3

65.291

kN

p2 E I
Le2

0.002 ( Le / ry 20 )

0.002 (

0.171

Buckling Resistance Pc
Where

( 1415.000 )

107.980

kN

65.291

}]

105.597 20 )

/2[ - { 2 - 4Pe. Pcs} ]

Pcs + (1 + n).Pe

65.291

191.756

+ [( 1 +

0.171 )

191.756

107.980

Buckling Resistance
1
Pc
/2[ - { 2 - 4Pe. Pcs} ]
=
=

1/2

191.756

- {

1/2

191.756

- {

36770.406

-(

1/2

191.756

- {

8570.116

)]

1/2

191.756

49.591

>

F=

92.575

12.338

kN

- (4 X

107.980
28200.291

OK !

X
)]

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

8 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

Combined Bending & Compression :


6.4.2 Local Capacity Check
( Fc / Pcs ) + (Mx / Mcx )
=

12.338

0.497

65.291 ) + (

< 1.000

146.9

/ 476.505 )

OK !

Member in Tension :
Member No.

Used Section:

, F

2.153

kN

T153060GAL

Ae

95.330

mm2

Py

550.000

Nmm-2

Ae.Py

95.330 X 550.000 /

52.432 kN

7.2.1 Tensile capacity, Pt

>

2.153

Combined Bending & Tension :


7.3

Local Capacity Check


( Ft / Pt ) + (Mx / Mcx )

2.153

0.349

52.432

< 1.000

) + (
OK !

146.9 /

476.505 )

1000.000 kN
kN

OK !

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

9 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

Deflection ( ) :
7

, Length L =

3183

mm, s (supported span deflection) = 0.949 mm

Member No.

L
2.4.2 Table 3 Deflection Limits
Supported span :

22

3183

/ 200 =

15.915 >

, Length L =

914

mm, c (Cantilever deflection)

OK!

= 1.605 mm

Member No.

L / 200 =

L
2.4.2 Table 3 Deflection Limits
Cantilever

L / 180 =

914

/ 180 =

5.078

>

OK!

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

10 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

CONNECTION STRENGTH CHECK


Fastener
#14 Gauge Teks (Class 2) Hex Head Self-Drilling Screw

d =

5.800

mm

#10 Gauge Teks (Class 2) Hex Head Self-Drilling Screw

d =

4.100

mm

or

ps (min)
py (min)

= 375.000 Nmm-2
= 550.000 Nmm-2

d
t3

4.100 mm

0.600 mm

t4

0.750 mm

ds

8.000 mm

Appendix A

A. 1,4
(a)

Shear Capacity, Ps
for t4 / t3

1.0

the smaller of
3 1/2
Ps
= 3,2 (t3 d) py
0.600 3 x 4.100 )1/2

3.2 (

1.656 kN

550 Nmm-2

and
Ps

= 2,1 t3 d py
=

Thus,

Ps

2.1 x 0.600 x 4.100 x

2.84

kN

1.66

kN

550 Nmm-2

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

11 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

for t4 / t3
2.5
Ps
2,1
t
d py
=
3

(b)

2.84

kN

1,0 < t4 / t3 < 2,5


t4 / t3
= 1.25
Ps
= interpolation between (a) and (b)

(c)

1.85

kN

The most suitable Ps to use is


4

(a)

(b)

(c)

nos .(min) drilling screw in shear strength (Member no. 23 ))


=
4
X 1.85 kN
=
7.415 kN
> 4.101 kN
OK !

Pf s

6.80

kN (provided by manufacturer)

Pf s

> 1.25 Ps
6.800 kN
>

2.32

kN

OK !

Tensile Capacity, Pt

A. 1,5

Pulling of the base material over the screw head or washer (t < 2,00mm & dw < 25mm)

(a)

Pt

= 1,1t3 ds py
= 2.904 kN

Pull out from the base material (t4 > 0,9mm)


Pt
= 0,65t4 ds py

(b)

NIL

kN

Tensile failure of the screw itself


Pf t
=
11.90
kN (provided by manufacturer)

(c)

Pf t

> 1.25 Pt
11.900 kN
>

3.63

The smallest value among (a), (b) or (c)


4

kN

2.90

OK !
kN

nos .(min) drilling screw in tensile strength (Member no.


3)
=
4
X 2.904 kN
=
11.616 kN
OK !
> 2.153 kN

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

12 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

BATTEN CHECK(BS 5950 : Part 5 )


N121042GAL

Used Section:

Batten span,L =

31.580 mm

t
Ys

0.420

Ix

0.885

Zx

0.540

Py

mm

550.000 Nmm-2
X 104 mm4
X 103 mm3

550.000 Nmm-2

1.351 m & Batten c/c spacing =

0.320

Loadings :
Batten self weight =
Concrete tile
=

0.030 kN/m2

0.320 m

0.010

kN/m

0.460 kN/m2

0.320 m

0.147

kN/m

Imposed load (w)

0.250 kN/m2

0.320 m

0.080

kN/m

0.237

kN/m

Strength Check :
Max. Bending Moment, Mmax

= WL2/8
=

Max. Bending Stress, M/Zx

5.2.2.2

0.237

0.054

)(

1.351 )2

X 10 6 /

0.054 kNm

/ 8 =

0.540

X 103 =

100.048

N/mm2

Max. Allowable Bending Stress = {1.13 0.0019(D/T)(Ys/280)1/2}Py


=
=

{1.13 - 0.0019 ( 31.580

/ 0.420 )( 550.000 / 280 )1/2 }

511.376 Nmm-2 > Max. Bending Stress

OK !

550.000 N/mm2

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

13 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

Deflection Check :
Max. Deflection

Table 3

5wL4/384EI

5(

1.96

1.351

X 103)4 / 384 (2X105) X

1.351

6.755

mm >

0.080

Max. Allowable Deflection =

)(

0.885

X 104

mm

L/200
103

200 mm
Max. Deflection

OK !

COOLDEC METAL INDUSTRIES SDN. BHD.


Project :
Subject :
Client :
Job. No :
Calc by:

Cadangan Membina Rumah Berkembar Di Mukim Kenor, Jajahan Kuala Kerai, Kelantan.
Truss Analysis Design T5 Construction Rev00
OKG - 02 - 010 - SD01 ( Cons )
Checked by:
Date:
Sheet :

Fikri

Lee HY

6-Mar-2013

14 of 14

BS 5950 Part 5 : Code of Practice for Design of Cold Formed Thin Sections

ROOF TRUSSES BRACING CHECK(BS 5950 : Part 5 )


Strength Check :
N121042GAL

Used Section:

Py

Ae

Bottom Chord Length

8.364

Roof Pitch ,PI

25

Truss Spacing

1.351

550.000 Nmm-2
47.700 Nmm-2

Design Forces for Bracing Chords are assumed to be 1/3 of the overall roof loading (1.4 Gk + 1.6 Qk)
acting horizontally to and in the weak axis of the roof truss. Such Design Forces are further assumed
to be taken by the Bracing Chord in the form of horizontal & axial tensile force.

Design Force

1/3 [(1.4 Gk + 1.6 Qk ) x {(Bottom Chord Length ) / cos PI} x Truss Spacing]

1/3 X [

6.317

1.520

X {

8.364 / cos 25 } X

1.351

kN

Tensile Strength of Bracing Chord

Py X Ae

550.000 X 47.700

26.235 kN

>

/
6.317

1000

kN
OK !