GTSEWMNCTSprocess|SCN

GettingStarted Newsletters

Hi,Guest

LogOn

JoinUs

Store

SearchtheCommunity

Products

Services&Support

AboutSCN

Downloads

Industries

Training&Education

Partnership

DeveloperCenter

Activity

LinesofBusiness

UniversityAlliances

Events&Webinars

Innovation

Browse

Communications

Actions

8Replies Latestreply:Apr8,20154:36PMbyDhilipanSundararajan

Share

Tweet

0 Like

DhilipanSundararajan

Apr1,20159:07PM

GTSEWMNCTSprocess
ThisquestionisNotAnswered.
HiExperts,

IhavenoexperiencewithEWM,thoughihaveworkedontheERPWarehousemanagement.EWM
seemstobebitdifficultforme

IamtryingtosetupECCEWMGTSintegrationforasimpletransitprocedurewithSafekeeping.

IcreatemyIBDinECC,entertheT1andMRN#,IseeaTransitbeingcreatedinGTSbythe
normalprocessandthesameIBDgetsdistributedtoEWM.
InEWM,IseethesameT1andMRNfromECCisavailableinEWM.Isetupthe"inyard"status
andseeanotherTransitbeingcreatedinGTSwiththesameIBD#.

WithoutT1andMRNonmyIBDinECC,noTransitinGTS.
NowwhenIkeyinT1/MRNinEWMandset"Inyard"statusformyIBDinEWM,Icanfinda
TransitinGTS.Soonly1TransitinGTS/

Somyquestionisontheusualprocess

1)ShouldwestopkeyingintheT1andMRNinECCanddoitonlyinEWM?

2)IthoughtwhenIsetup"inyard"statusinEWMforthesameMRNthatwaskeyedinECC,system
willstillcheckifthereisaTransitavailablealreadywiththesameMRN#beforecreatinganewtransit
inGTS

Cansomeonehelpmewiththestandardprocedureplease?

Thanks
Dhilipan

HelpfulAnswerbyMouazBENREDJEB

189Views

AverageUserRating
(0ratings)

MouazBENREDJEB Apr1,20159:57PM (inresponsetoDhilipanSundararajan)

HelpfulAnswer Re:GTSEWMNCTSprocess
HelloDhilipan,

InthefewprojectswhereIhaveparticipatedtoimplementNCTS,Ineverencounteredthecasewhere
EWMwasused.

SoIamtryingheretoansweryourquestionsbasedonmyproperexperienceeventhoughasstated
aboveIneverencounteredthecasewhereEWMwasinvolved.

http://scn.sap.com/thread/3721787

1/5

5/11/2015

GTSEWMNCTSprocess|SCN

Iwillfirststartbyansweringyour2ndquestion

.Indeed,GTSshould"aggregate"thedifferentIBDs

thatsharethesameT1/MRNnumber.Inotherwords,youshouldhaveauniqueTransitdeclarationin
GTSformultipleIBDwiththesameTx/MRNnumber.

Frommyexperience,theonlycaseweretheaggregationdidnotworkwaswhenahugenumberof
IBDswasupdatedsimulatenouslyinECCwiththesameMRNnumber(foronecustomer,wehad
sometimes50IBDsupdatedwiththesameMRNnumberthroughaZprograminasingleshot).In
suchcases,GTSdidnotcopewiththevolumeofdatareceivedandstartedtocreatemultipleTransit
documentsinsteadofaggregatingthembasedontheMRN.

Inthetestcaseyouhavedescribedinyourpost,whatwasthestatusofthe1stTransitdocument
(createdbytheIBD)whenthe2ndTransitdocument(createdbyEWM)wascreated?

Movingnowtoyourfirstquestion,ifyou/wedon'tfindthereasonwhytheIBDsarenotaggregated,
thenindeed"maybe"youwillhavetoentertheMRNonlyinEWM,"maybe".Inmyopinion,partof
theanswerisnottechnicalbutratherpractical:TheMRNhastobeenteredmanuallyintothesystem.
Doesthereceptiondepartmenthaveaccess/authorizations/knowledgetodoitdirectlyinEWM???

Regards.

MouazBENREDJEB

Like(0)

DhilipanSundararajan Apr1,201510:48PM (inresponsetoMouazBENREDJEB)

Re:GTSEWMNCTSprocess
HiMouaz,

Thanks.Nicetohearfromyourafteralongtime.

IhadthesameopiniononIBDsandTransitrelationship.

SAPisasmallworld .Ihadopportunitytocheckthesameprogram thatyouaredescribing


toupdateMRNformultipleIBDs.IndeeditsbecauseofhugevolumesandwhentheRFC
queuesstartprocessingsimultaneouslyitcreatesmultipletransits.Settingupdelaystatements
inthecustomtransactiondoesn'thelpalwayswhentherearetoomanyIBDsbeingprocessed
simultaneously.Ithinkwemustensurethereisatransitcreatedforthe1stIBDbeforeprocessing
withtheMRNupdatefor2ndone(Justafterthe1stoneisupdated).NotforallIBDsthough.Just
between1stand2ndone.

RegardingTransitstatus:

WhentheT1andMRNwasupdatedintheIBDinECC,wehadatransitcreatedreadyand
availableinGTS.Howeverarrivalnotificationwasnotsent.

InEWM,statusforthesameIBDwassetto"Inyard"AnewtransitgotcreatedinGTSwiththe
sameMRNwhichwasshockingforme.

Fewminutesbackwhenichecked(whichis4hourslatertocreationofthetransitbyEWM).Isee
achangelogbytheRFCuserfromEWMsystemhadcanceledtheTransitdeclaration.

CouldbesomeonehadremovedthedeliveryassignmentinEWM.Ineedtocheckandconfirm
this.

Myexpectationis

1)IfIupdatetheT1andMRNinECC,letthetransitbecreatedinGTS.ButwhenIsettheIBD"in
yard"statusinEWM,itshouldcheckwhetherthereisatransitavailablealreadyforthesame
MRNbeforecreationI'llexecutesomemoretestsandconfirmthis.

Thanksforyourinputsasalways

Regards
Dhilipan

Like(0)

MouazBENREDJEB Apr2,20158:47AM (inresponsetoDhilipanSundararajan)

Re:GTSEWMNCTSprocess
HiDhilipan,

http://scn.sap.com/thread/3721787

2/5

5/11/2015

GTSEWMNCTSprocess|SCN

IhadalookatthepieceofcodewheretheaggregationofMRNistakingplaceinGTS.

Ihaveseen2thingsthatcouldexplainyourissue:

(1)OtherthantheTx/MRNnumber,theaggregationlogictakesintoaccountotherthingslike
theLogicalsystem.SomaybetheaggregationisnotworkinginyourcasebecauseECC
andEWMarenotsharingthesameLogicalsystem?

(2)IBDstransferredtoGTSaremappedintable/SAPSLL/CORREF.Pleasetrytohavea
lookatthistable.Ifyoufind2entrieswiththesameIBDnumberthenmaybethereisa
mismatchinoneofthe"secondary"fieldsofthetablethatcouldexplainyourissue(e.g.
sameIBDnumberbutdifferentObjecttype,ReferenceApplication,etc...)

Regards.

MouazBENREDJEB

Like(0)

DhilipanSundararajan Apr7,20151:48PM (inresponsetoMouazBENREDJEB)

Re:GTSEWMNCTSprocess
HiMouaz,

Thanksforyourhelp

1)IthinkitwasjustthetimingissuetohavemultipletransitsforsameMRN.Itriedwitha
freshflowwithall3systemstogether.ThereisjustonetransitcreatedevenafterIsetin
yardstatusformyIBDinEWM.So,multipletransitissueisjustaveryrarecase.

2)IseeadifferenceintheCORREFtableupdatewithrespecttotheQALREF.
WheneveranIBDisreplicatedfromEWM,theQALREFissetasEXTIDFandnotas
EXTID.

ThisisleadingmetoanotherissueforwhichIamworkingwithSAP

So,whenmytransitiscreatedfromEWMsystemdirectly.WhichmeansIentertheT1
andMRNinEWMandsetthestatusas"Inyard"AtransitgetscreatedinGTS.This
transitiscreatedunderQALREFEXTIDFinCORREFtable.

WhenwegetintheTransitDisplayInboundactivitiestransactionandtrytofindoutthe
TransitwiththeInbounddeliverynumber.Itdoesn'tshowmytransitdeclaration
becausethestandardcodeisconsideringtheQALREFtobe"EXTID"alwayswhenwe
mentionthefeedersystemdata.

I'llkeepyoupostedifIgetanyresponsefromSAP.
Thanks
Dhilipan

Like(0)

DaveWillis Apr7,20153:57PM (inresponsetoDhilipanSundararajan)

Re:GTSEWMNCTSprocess
HiDhilipan,

That'sstrange,since(asfarasIcansee)thestandardcodeiscorrect.

IfyoulookintoFunctionModule/SAPSLL/MM0B_6800_TIBD_MAP_R3atline24,
you'llsee:

http://scn.sap.com/thread/3721787

3/5

5/11/2015

GTSEWMNCTSprocess|SCN

es_api_tibdqual_refno=gc_qalrefexternal_number.

Anddoubleclickingtheconstantshows:

constants:
beginofgc_qalref,
external_numbertypechar6value'EXTID',
external_number_flowtypechar6value'EXTIDF',
endofgc_qalref.

Areyousureyou'renotchangingthevalueintheBAdIoranywhereelse?

Regards,
Dave

Like(0)

DhilipanSundararajan Apr8,20154:36PM (inresponsetoDaveWillis)

Re:GTSEWMNCTSprocess
HiDave,

ThisworkswithEXTIDwhenmytransitisreplicatedfromECC.Inmycase,I
amfacingissueswhenthetransitisbeingreplicatedfromEWMsystem.

I'venotcheckedthecodeinEWMyet.Tobefrank,noclueonwhichcodeto
checkinEWM

Regards
Dhilipan

Like(0)

DaveWillis Apr6,201511:39PM (inresponsetoDhilipanSundararajan)

Re:GTSEWMNCTSprocess
HiDhilipan,

Apologiesforalateresponsehere(holidays)...

ToaddresstheissuewiththeRFC,takealookatNote1875119,createdforoneofmy
projectssometimeago.ItallowstheuseofqRFCinsteadoftheusualtRFC,andmakesa
worldofdifferencewhentryingtotransferlargenumbersofDeliveriestogether.

ObviouslythatNoteisforanERPfeedersystem,butmaybeSAPwouldalsoprovidethe
samefunctionalityforEWM(you'dneedtocreateanIncidenttomakethatrequest).

Regards,
Dave

Like(0)

DhilipanSundararajan Apr7,20151:53PM (inresponsetoDaveWillis)

Re:GTSEWMNCTSprocess
HiDave,

Thanksalot.We'vedonethischangealreadyinourECCsystem.Asyousaid,wemay
havetousesimilarlogicinEWMifwecomeacrossthesameissueinfuture.

Thanks
Dhilipan

Like(0)