Uk048e New Range Ledi
Uk048e New Range Ledi
Uk048e New Range Ledi
CAUTION! Carefully read this material before getting started. There are security measures to follow
during the installation process.
The electric installation must be made according to NF C 15-100.
A circuit-breaker or splitting switch must be incorporated into cabling installation. This device must
support the voltage value and nominal current indicated on the device.
The products of GORY TIMING are compliant to: CE, EN60950, EN55022, and EN50024
Table of content
1.2
1.3
Ceiling mounting with bracket single and double face model(LEDI REVERSO Model) .........5
1.4
Side mounting with bracket - single and double face model (LEDI REVERSO Model) .............5
1.5
1.6
ELECTRICAL Connections..............................................................................................................9
3.1
3.1.1
Impulse receiver version, AFNOR NFS 87-500 code version, radio-synchronised version
3.2.1
Impulse Receiving Version, AFNOR NFS 87500 code, radio synchronized with TDF or
DCF
.........................................................................................................................................10
3.2.2
3.3
Synchronisation .............................................................................................................................11
Configuration .................................................................................................................................12
3/16
1 ASSEMBLY OVERVIEW
Only for Ledi 5/60 ; 7/60 ; 7/60 alpha and alpha carr
=
B-20 mm
B-10 mm
=
Minimum opening
85 mm
WALL
A-20 mm
WIRE OUTPUT
63 mm
4/16
1.3 CEILING MOUNTING WITH BRACKET SINGLE AND DOUBLE FACE MODEL(LEDI REVERSO
MODEL)
1.4 SIDE MOUNTING WITH BRACKET - SINGLE AND DOUBLE FACE MODEL (LEDI REVERSO MODEL)
5/16
threaded pin
Bracket 50x30 mm
puck
clock
Clock clapper ring
6/16
A/2
B(mm) (Ledi Reverso)
Digits Height
(hours/minutes)
A(mm)
50
300
120
150
LEDI 5.60
50
270
270
135
70
350
165
175
70
430
165
215
LEDI 7.60
70
390
390
195
70
390
390
195
100
500
210
250
100
640
210
320
70
625
165
312.5
70
715
165
357.5
70
390
390
195
70
650
220
325
70
760
220
380
70
390
540
195
100
770
210
385
100
930
210
465
Model
LEDI 5.S
LEDI 7
LEDI 7.S
LEDI 7.60.S
LEDI 10
LEDI 10.S
LEDICA 7.M
LEDICA 7.M.S
LEDICA ALPHA CARREE 7.M
LEDICA ALPHA 7.M
LEDICA ALPHA 7.M S
LEDICA ALPHA 7.60
LEDICA 10.M
LEDICA 10.M.S
(mm)
7/16
GENERAL CHARACTERISTICS
LEDI REVERSO Range: Single or double face Ceiling or side mounting with bracket support.
AVAILABLE VERSIONS (according to model):
Stand alone version:
TCXO quartz time base built-in 32Khz
Minute impulse input, parallel connection:
Minute 24V reversed impulse. Impulsion duration: 0.1sec.
Impulsion consumption : 6 mA / 24V
Half-minute impulse input, series connection :
Series connection on an external 39 Ohms shunt.
minute impulse reversed impulse every minute.
Impulsion duration: 0.1sec.
Impulsion consumption : 1.25 V
Line intensity : 60 mA to 120 mA
AFNOR NFS 87500 input code
Nominal input level : 2.2Vcc
Input impendance : 3.5 Kohms
Minimal input voltage : 70 mVcc
Ethernet version synchronised by NTP or PoE (Power over Ethernet):
Uses a NTP server as time reference.
Connect the mains supply for the NTP version.
Make sure to use either a PoE switch or a Mid Span injector for the PoE version.
The Ethernet interface user guide and the configuration tool are available on the CDROM supplied with the clock.
DHW 869.525MHz Radio input
The clock is automatically synchronized according to the configuration of the transmitter.
Radiosynchronised on DCF
Frequency: 77.5 KHz
th
Place the antenna in a way that antennas LED is flashing every second and nothing at 59 seconds.
Radiosynchronised on TDF
Frequency: 162 KHz
Install the antenna on a horizontal basis.
th
After a minute, the antennas LED should start flashing every second and nothing at 59 seconds.
Note:
The maximum cables length using a shielded bi-wired cable is 100 meters.
The maximum distance relative to the DCF transmitter (Frankfurt - Germany) or TDF (Allouis CHER) =
2,000 Kms.
(Value may decrease depending on the surrounding terrain and weather conditions)
8/16
ELECTRICAL CONNECTIONS
Wall Clock
Fix the wall according to the previous paragraph.
Flush Mount Clock
Wall preparation:
Prepare a opening which shall match the dimension for your clock(according to the previous paragraph).
Fit in place the bracket with M3 screws (not supplied).
Place your clock in the slot. This will be held in place automatically by magnetization.
Wires output at the back of the case via the connector plug.
E/SASCII
TXD
RS232 ou
E/S+
RS485
RXD
Probe
TC
GND
OFF
ON
CODE
+
_
NC
PROG
B1
3.1.1 Impulse receiver version, AFNOR NFS 87-500 code version, radio-synchronised version on TDF or
DCF
Connect the impulse, AFNOR NFS 87500 code, TDF antenna or DCF antenna to the identified code input on
terminal B1.
If the 2 points CODE are not connected, the clock switches to stand alone version.(except for impulse receiver
version)
3.1.2 Version ASCII RS232 or RS485
ASCII RS232C
ASCII RS422/485
1 : GND
1 : E/S -
2 : TXD
2 : E/S+
3 : RXD
3 : GND
The clock works as stand-alone but is set with respect to the ASCII code that it receives (configuration 2400
bauds, 8-bit format, even parity, 1stop bit).
This ASCII code must be Time information in the form:
SXT day of week SP day of month/month/year SP SP hour: minute: second CR
Generated either by RT4000 or by all other ASCII code generators.
Remark :
In case of mains failure, the display turns off, but the time is save thanks to its internal battery.
3.2 LEDI REVERSO MODEL: CURRENT SECTOR/TIME CODE/DISPLAY
UK048E User manual New range LEDI
9/16
Connect the mains power on the 2 wires. The connections have to be made on this cable: the casing is sealed
and cannot be opened.
To access to the push buttons and the switch, unscrew and slip down the pit, which is located on the underside of
the case.
Switch on and reset the clock.
3.2.1 Impulse Receiving Version, AFNOR NFS 87500 code, radio synchronized with TDF or DCF
Connect the impulse, AFNOR NFS 87500 code, TDF antenna or DCF antenna on B1 connector (2 CODE points)
3.2.2 Version ASCII RS232 or RS422
Wiring code for ASCII 232 or 485 versions on RxD, TxD, GND
10/16
4 BRIGHTNESS SETTING
This setting is achieved manually by pressing the button + and outside any configuration mode.
5 SYNCHRONISATION
To set the new minute, configure Hours/Minute, by pressing Prog and + or -, if any change are made on the
minute unit, pressing PROG will start the newly settled minute.
REMARKS
-
11/16
6 CONFIGURATION
Setting the time is via 3 buttons +, - and PROG are accessible on the back panel.
Keeping buttons +/- pressed will change value even faster.
The setting time between the menus is 80 seconds
Hour/minute Configuration
PROG
OFF
+/-
ON
+
PROG
Hours setting
+/-
PROG
PROG
Minutes setting
+/-
PROG
Digits colour
+/-
Colour choice
d1=red d2=amber d3=green
PROG
Colour of circle
Ledi 5.60 et Ledi 7.60
+/-
Colour choice
u1=red u2=amber u3=green
PROG
Configuration validation
12/16
PROG
+/-
PROG
+/-
5 ALT HOUR
Tempo = 5 seconds
+/-
3 ALT HOUR
Tempo = 3 seconds
PROG
Temperature tempo
PROG
Hours setting
+/-
PROG
Minutes setting
+/-
PROG
Digits Colour
+/-
Colour choice
d1=red d2=amber d3=green
PROG
Colour of circle
Ledi 5.60 et Ledi 7.60
+/-
Colour choice
u1=red u2=amber u3=green
PROG
Configuration validation
13/16
MONTH / YEAR
HOURS
MINUTES
Date of
month
DAY
HOURS
MINUTES
MONTH / YEAR
PROG
+/-
PROG
Month tempo
+/-
3 ALT HOUR
Tempo = 3 seconds
+/-
4 ALT HOUR
Tempo = 4 seconds
PROG
Year tempo
PROG
+/-
Year setting
PROG
+/-
Month setting
PROG
+/-
Display on 2 digits
PROG
Digits colour
+/-
Colour choice
d1=red d2=amber d3=green
+/-
PROG
OFFSET shift
PROG
+/-
Language
PROG
OFF
(futur menu)
+/-
PROG
Configuration validation
UK048E User manual New range LEDI
14/16
Comments
15/16
Gorgy Timing RC74B38 All modifications of technical order, aesthetic, colour can be made without notice.