Specifications
Power Requirement :
Unregulated + 10 to + 30 V dc with protection from power reversals
Case :
Powder painted Sheet metal Enclosure
Accessories (supplied):
DIN rail Mounting bracket
Plug-in screw terminal wiring:
Accepts AWG 1-#12 to #22 (0.5 to 2.5 mm) wires
Baudrate(BPS)(switchable)
: 1200,2400,4800,9600,19200,38400,
57600,115200
RTS control
: switch selectable
RS-232 interface connector
: Female DB-9
RS-422/RS-485 interface connector : plug-in screw terminal
Power consumption
: 1.2 Watt
Operating Environment
Operating Temperature
Storage temperature
Humidity
INSTALLATION
Initial inspection
We have inspected the CS-1520 modules both mechanically and electrically before we
shipped them. They should be free of marks and scratches and in perfect order on
receipt.
As you unpack the modules check them for signs of shipping damage (damaged box ,
scratches, dents, etc.)If it is damaged or fails to meet our specifications, notify
our service department or your local sales representative immediately. Also call the
carrier immediately and retain the shipping carton and packing material for
inspection by him. we will make arrangements then to repair or replace the material.
Switch and jumper settings
Switch settings
DIP switches in the CS converter set the data format (number of bits) and baud rate
for the network. Your program and PCs serial port should match the settings of the
connector and repeater modules.
1. Data Format: (Sw1-6,7)
Data can be 9, 10, 11 or 12 bits. Table1 gives required switch settings in the
module for necessary set up. The factory default is 10 bits, which is one start
bit, eight data bits, no parity bit and one stop bit. This combination is widely
known as and referred to as N, 8, 1.
SW1-4
0
1
RTS mode
Self RTS
PC RTS
Default settings
Modules are not addressable by the host computer, the baud rate and data format must be set using sw1
located inside the module as per above tables. The default settings of the switch are shown in table given
below.
Baud Rate
Mode
RTS
FORMAT
9.6 KBPS.
RS 232 TO RS 485 .
SELF RTS
10 Bit ( 1 Start + 8 Data + 1 Stop)
Power supply
For the ease of use in industrial environment, the modules are designed to accept
industry standard +24 V DC unregulated power. Operation is guaranteed when using any
power supply between +10V and +30V DC. Power ripples must be limited to 5 V (or 0.5
volt) peak to peak while the voltages in all cases must be maintained between +10 and
+30 volts dc. Power supply specifications are referenced at module connector. The
power cables should be selected according to the number of modules connected and the
length of the power lines. When using a network with long cables, we advice the use
of thicker wire to limit line voltage drop. In addition to serious voltage drops,
long voltage lines can be the cause for interference with communication lines
We advise that the following standard colours (as indicated on the modules) be used
for power lines.
+ Vs
GND
( R )
( B )
RED
BLACK
(Y) Yellow
(G) Green
RS
DATA+
485
DEVICE DATA -
DATA+
DATA
HPCS
1520
RS
422
RX+
TX+
RX
TX
DEVICE
TX+
RX+
TX-
RX -
TXD
RXD
RXD
TXD
RTS
RTS
GND
GND
PC