Design of Two-Way Restrained Slab (IS456:2000)
Design of Two-Way Restrained Slab (IS456:2000)
S1
Design Of Two-way Restrained Slab (IS456:2000)
Slab Group
20 Mpa
415 Mpa
125 mm
20 mm
4m
4.7 m
0.058
0.047
5.75 KN/m2
2 KN/m2
mm
Suggestion
CHECK For
[1] or [0]
125,150.175,200
20,25,30
Revision
1= ok
1
0=fail,increse depth of slab
64
105 mm
1= ok
Check for spacing of bars
along SHORT span
(Middle Strip)
125 mm
10 mm
128 mm or less
Check for spacing of bars
along LONG span (Middle
Strip)
150 mm
8 mm
300 mm
8 mm
1
0=fail,increase bar dia or
decrease spacing along
short span
1= ok
175 mm or Less
Check for spacing of bars
along ANY span (Column
Strip)
8,10,12,16
1
0=fail,increase bar dia or
decrease spacing along
short span
399 mm or less
8,10,12
1= ok
500 mm
500 mm
481
1
1 length
0=fail,increase curtailment
22
23 Permissible shear stress in concrete
Increased Shear strength of concrete due
to slab action
1= ok
1.3
Concrete Mpa
Slab-
IS456:2000,Annex D
D1.9 page 90
S1
number of layers
4
Reinforcement area required
numbers of 8 mm
bars per layer ( only
extra 2-layers)
spacing (mm)
Code IS456:2000
annex D
D1.8
D1.8
87 (= 0.75*Atx)
186 (= 0.75*Aty)
9
4
Type-II
numbers of 8 mm
number of layers
bars per layer
spacing (mm)
Reinforcement area required
along X
230 mm2
5
along Y
107 mm2
2
Length extension from edge
along X
800 mm
along Y
800 mm
Code IS456:2000
annex D
D1.9
174
373
Type-II
numbers of 8 mm
number of layers
bars per layer
Reinforcement area required
along X
0 mm2
along Y
0 mm2
Length extension from edge
along X
0 mm
along Y
0 mm
Bottom bar continuity (Not reqd at the
support side upto distance) X-dir (mm)
Continuous side of Slab
1000
Terminating side of Slab
600
Code IS456:2000
annex D
D1.10
spacing (mm)
0
0
0
0
0
0
0
0
Code IS456:2000 annex D ,
D1.4
Y-dir (mm)
1175
705
Tension(negative
moment)reinforcement at support
Continuous edge
Code IS456:2000
Reinforcement area required numbers( not less than)spacing (not more than) annex D, D1.5
along X
307 mm2
4
153
along Y
143 mm2
3
247
Length extension from edge
along X
600 mm
along Y
705 mm
Non-Continuous edge
Code IS456:2000
Reinforcement area required numbers( not less than)spacing (not more than) annex D, D1.6
along X
307 mm2
4
102
along Y
143 mm2
3
165
Length extension from edge
along X
400 mm
along Y
470 mm
Percentage of steel(%) At
Concrete
MPA
0.32 Percentage
20
(N/mm2)
of steel(%)
At
20MPA 25MPA
< 0.15
0.18
0.25
0.22
0.5
0.3
0.19
0.23
0.31
30MPA
0.2
0.23
0.31
0.75
1
1.25
1.5
1.75
2
2.25
2.5
0.35
0.39
0.42
0.45
0.47
0.49
0.51
0.51
0.36
0.4
0.43
0.46
0.49
0.51
0.53
0.55
0.37
0.41
0.45
0.48
0.5
0.53
0.55
0.57
2.75
3.00 and
above
0.51
0.51
0.56
0.57
0.58
0.6
225.000
1.15
200.000
1.20