s05nmdl2sm PDF
s05nmdl2sm PDF
s05nmdl2sm PDF
Certified Quality
Model S05
3: EXP VIEW
2: INSTAL & OP
Non-Metallic
Design Level 2
1: PUMP SPECS
TROP EGR
T
4: AIR END
Quality System
ISO 9001 Certified
TELNI
TPNF
5: WET END
6: OPTIONAL
831
7: WARRANTY
Safety Information
IMPORTANT
WARNING
When used for toxic or aggressive fluids, the pump should
always be flushed clean prior to disassembly.
When the pump is used for materials that tend to settle out
or solidify, the pump should be flushed after each use to
prevent damage. In freezing temperatures the pump should be
completely drained between uses.
Airborne particles and loud noise hazards. Wear eye and ear
protection.
CAUTION
WARNING
Pump not designed, tested or certified to be powered by
compressed natural gas. Powering the pump with natural
gas will void the warranty.
To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.
Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.
To reduce the risk of static electrical sparking, this pump must be grounded. Check the local
electrical code for detailed grounding instruction and the type of equipment required.
Refer to nomenclature page for ordering information.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or
other miscellaneous equipment must
be grounded.
sandpiperpump . com
s05nmdl2sm-rev0814
sandpiperpump . com
s05nmdl2sm-rev0814
2: INSTAL & OP
3: EXP VIEW
4: AIR END
5: WET END
6: OPTIONAL
7: WARRANTY
1: PUMP SPECS
Table of Contents
1: PUMP SPECS
Pump
Brand
Model
#:
Pump
Size
Check
Valve
Pump
Style
Pump
Options
Kit
Options
S XX X X X X X X X X X XX
Pump Brand
S SANDPIPER
Pump Size
05 1/2"
Design Level
2
Design
Level
Design Level
Wetted Material
K PVDF
N Nylon
P Polypropylene
C Conductive Polypropylene
V Conductive PVDF
Kit Options
00. None
P0. 10.30VDC Pulse Output Kit
P1. Intrinsically-Safe 5.30VDC,
110/120VAC 220/240 VAC
Pulse Output Kit
P2. 110/120 or 220/240VAC
Pulse Output Kit
E0. Solenoid Kit with 24VDC Coil
E1. Solenoid Kit with 24VDC
Explosion-Proof Coil
E2. Solenoid Kit with 24VAC/12VDC Coil
E3. Solenoid Kit with 12VDC
Explosion-Proof Coil
E4. Solenoid Kit with 110VAC Coil
E5. Solenoid Kit with 110VAC
Explosion-Proof Coil
E6. Solenoid Kit with 220VAC Coil
E7. Solenoid Kit with 220VAC
Explosion-Proof Coil
E8. Solenoid Kit with 110VAC, 50 Hz
Explosion-Proof Coil
E9. Solenoid Kit with 230VAC, 50 Hz
Explosion-Proof Coil
SP. Stroke Indicator Pins
S Stainless Steel
T Virgin PTFE
Porting Options
N
B
1
2
3
4
5
6
NPT Threads
BSP (Tapered) Threads
Dual Porting (NPT)
Top Dual Porting (NPT)
Bottom Dual Porting (NPT)
Dual Porting (BSP Tapered)
Top Dual Porting (BSP Tapered)
Bottom Dual Porting (BSP Tapered)
Pump Style
S Standard
I Inline Porting NPT Threads
Pump Options
0 None
1 Sound Dampening Muffler
2 Mesh Muffler
6 Metal Muffler
7 Metal Muffler with Grounding Cable
ATEX Detail
(1)
(2)
II 1G c T5
IIII 2GD
3/1 GT5c T5
II 1D c T100C
I M1 c
I M2 c
Note: Pumps are only ATEX compliant when ordered with
wetted material option C or V, Non-wetted material
option C, pump option 0, 6 or 7, and kit option 0.
II 2G
2G Ex
Ex ia
ia cc IIC
IICT5
T5
II
II 2D
3/2 cGiaD
Ex 20
ia cIP67
IIC T100C
T5
II
II 2D Ex c ia 20 IP67 T100C
Note: Pumps ordered with the options listed in (1) are ATEX
compliant when ordered with kit option P1.
(3)
(4)
2G EEx
EExmmccT5
II T5
IIII 2G
3/2c2G
EEx
m c II T5
IIII 2D
IP65
T100C
II 2D c IP65 T100C
Note: Pumps ordered with the options listed in (1) are ATEX
compliant when ordered with kit option A1, A2, A3, or A4.
Compressed Air Temperature Range: Maximum Ambient
Temperature to plus 50C.
IEC EEX m T4
sandpiperpump . com
s05nmdl2sm-rev0814
Performance
S05 NON-METALLIC
HEADS UP TO
100 psi or 231 ft. of water
(7 bar or 70 meters)
DISPLACEMENT/STROKE
.026 Gallon / .098 liter
0P
80
70
60
SI
12 (20)
Bar
14 (24)
2 Bar
20 PS
I (1.3
16 (27)
ar)
I (2.7
10
0
8 (13.5)
.08 B
40 PS
30
.44
SI (4
20
1
ar)
I (5
60 P
40
6 (10)
8B
10 (17)
PS
50
3
4 (7)
(6.
6 Bar)
Air Inlet
Pressure
10
SHIPPING WEIGHT
Polypropylene 16 lbs. (8kg)
PVDF 18 lbs. (9kg)
NPSHR
90
80
1: PUMP SPECS
PSI
10
10
11
20
30
40
12
13
14
50
15
METERS
SOLIDS-HANDLING
Up to .125 in. (3mm)
2 (3.5)
7 100
6
HEAD
Performance based on the following: elastomer fitted pump, flooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
FEET
CAPACITY
0 to 14 gallons per minute
(0 to 52 liters per minute)
BAR
30
25
20
15
10
5
9.1
7.6
6
4.5
3
1.5
16
60
Materials
Material Profile:
Operating
Temperatures:
Max.
Min.
190F
88C
-20F
-29C
280F
138C
-40F
-40C
350F
177C
-40F
-40C
220F
104C
-20F
-29C
200F
93C
-10F
-23C
190F
88C
-10F
-23C
180F
82C
32F
0C
180F
82C
32F
0C
250F
121C
0F
-18C
275F
135C
-40F
-40C
180F
82C
-35F
-37C
150F
66C
32F
0C
220F
104C
-35F
-37C
Maximum and Minimum Temperatures are the limits for which these materials can be operated.
Temperatures coupled with pressure affect the longevity of diaphragm pump components.
Maximum life should not be expected at the extreme limits of the temperature ranges.
Metals:
Alloy C: Equal to ASTM494 CW-12M-1 specification for nickel and nickel alloy.
Stainless Steel: Equal to or exceeding ASTM specification A743 CF-8M for corrosion
resistant iron chromium, iron chromium nickel and nickel based alloy castings for
general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.
sandpiperpump . com
s05nmdl2sm-rev0814
DISCHARGE PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)
10.11 257
A
1.48
3.07 78
1.75 44
AIR INLET
1/4 FNPT
11.54 293
1: PUMP SPECS
9.79 249
DISCHARGE PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)
AIR INLET
10.11 257
1/4 FNPT
A
3.07 78
5.45 138
1.75 44
MANIFOLD CAN ROTATE 90
FROM VERTICAL CENTERLINE
1.38 35
AIR INLET
1/4 FNPT
9.79 249
SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)
9.79 249
.07 2
1.75 44
5.45 138
4X .36 9
MTG. SLOT
11.54 293
1.38 35
AIR INLET
1/4 FNPT
Mesh & Sound
Standard Integral
Dampening Muffler
Muffler Option
Option
S05 NON-METALLIC
CENTER PORTED OPTION
5.45 138
SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)
ER
1.48
7.13 [181]
8.81 [224]
9.79 249
.07 2
1.75 44
GENERAL NOTES
.07 2
1.
2.
5.45 138
ALLIC
OPTION
.125 [3mm]
7.13 [181]
8.81 [224]
2.
8.81 [224]
1.75 44
.07 2
6.56 167
GENERAL NOTES
1.
7.13 [181]
SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)
4X .36 9
OPTIONAL SUCTION & MTG.
DISCHARGE
SLOT PORTS AVAILALBE IN 1" BSP
PART NUMBER
M
Standard Integral Da
Muffler Option
S05 NON-METALLIC
A
DIMENSIONAL TOLERANCE
= .125 [3mm]
MADE FROM
TOLERANCES
MATERIAL
S05 Non-Metallic Inline Ported Options - (Polypropylene Wet End Models Only)
3.63 92
.XX
.XXX
HOWN) COVERS
3/8" FNPT EXHAUST6
7
YLES OR PIPING EXHAUST AIR IN
D.1
REVISED DRAWING
MF
4/23/2010
REV
REVISION
CHG
DATE
PUMP REFERENCE
APP
DATE
DESCRIPTION
1/2
SURFACE FINSH
ASS'Y REFERENCE
ECN
.010
.005
ANGULAR
1.
63
DRAWING NUMBER
D.1
450.319.001
2.
STANDARD INTEGRAL MUFFLER (SHOWN) COVERS 3/8" FNPT EXHAUST
SHEET 1 of 2
3.04 77
2X 1.75 44
11.76 299
DISCHARGE PORT
1/2" FNPT
AIR INLET
1/4 FNPT
10.62 270
9.79 249
5.45 138
1.38 35
SUCTION PORT
1/2" FNPT
.38 10
6.16 157
4X .31 8
MTG. SLOT
Mesh & Sound
Standard Integral Dampening
Muffler
Muffler Option
Option
S05 NON-METALLIC
IN-LINE PORTED OPTION
7.13 [181]
4.88 124
3.63 92
GENERAL NOTES
1.
2.
6.56 167
7.13 [181]
IDEX AODD
UNLESS OTHERWISE
SPECIFIED
sandpiperpump . com
s05nmdl2sm-rev0814
8.81 [224]
Air Line
Discharged
Fluid
2: INSTAL & OP
Suction
Stroke
Primed
Fluid
SAFE AIR
Suction (side) stroking also initiates the reciprocating
EXHAUST
(shifting, stroking or cycling) action of the pump.DISPOSAL
The suction
AREA its
diaphragms movement is mechanically pulled through
stroke.
1" DIAMETER
AIR The diaphragms inner plate makes contact with an
EXHAUST PIPING
actuator plunger aligned to shift the pilot signaling valve.
Once actuated, the pilot valve sends a pressureMUFFLER
signal to the
opposite end of the main directional air valve, redirecting the
compressed air to the opposite inner chamber.
SUBMERGED ILLUSTRATION
MUFFLER
LIQUID
LEVEL
SUCTION
LINE
sandpiperpump . com
s05nmdl2sm-rev0814
SUCTION
LINE
Unregulated Air
Supply to Surge
Suppressor
Surge Suppressor
2: INSTAL & OP
Pressure Gauge
Shut-Off Valve
Pipe Connection
(Style Optional)
Flexible Connector
Discharge
Check
Valve
Muffler
(Optional Piped Exhaust)
Shut-Off
Valve
Drain Port
Flexible Connector
Vacuum
Gauge
Air Inlet
3
Filter Regulator
P/N: 020.V107.000
Air Dryer
Suction
CAUTION
Shut-Off Valve
Drain Port
sandpiperpump . com
s05nmdl2sm-rev0814
Troubleshooting Guide
Pump Cycles Once
Potential Cause(s):
Product Leaking
Through Exhaust
Premature Diaphragm
Failure
Cavitation.
Excessive flooded suction pressure.
Unbalanced Cycling
Recommendation(s):
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Install gaskets with holes properly aligned.
Remove pilot valve and inspect actuator plungers.
Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Check the air line size and length, compressor capacity (HP vs. CFM required).
Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators.
Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Remove muffler screen, clean or de-ice, and re-install.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Disassemble and inspect wetted chambers. Remove or flush any obstructions.
Check suction condition (move pump closer to product).
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged.
Use heavier valve ball material.
Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical
Resistance Guide for compatibility.
Check Chemical Resistance Guide for compatibility.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Remove or flush obstruction. Check and clear all suction screens or strainers.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Visually inspect all suction-side gaskets and pipe connections.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Remove muffler screen, de-ice, and re-install. Install a point of use air drier.
Clean manifolds to allow proper air flow
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Check suction (move pump closer to product).
Check the air line size, length, compressor capacity.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling.
Meet or exceed pump connections.
Install a larger air line and connection.
Visually inspect all suction-side gaskets and pipe connections.
Remove or flush obstruction. Check and clear all suction screens or strainers.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous.
Replace diaphragms, check for damage and ensure diaphragm plates are tight.
Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility
with products, cleaners, temperature limitations and lubrication.
Enlarge pipe diameter on suction side of pump.
Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.
Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations
and lubrication.
Check Operating Manual to check for correct part and installation. Ensure outer plates have not been
worn to a sharp edge.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Meet or exceed pump connections.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Visually inspect all suction-side gaskets and pipe connections.
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Purge chambers through tapped chamber vent plugs.
2: INSTAL & OP
Symptom:
For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388
sandpiperpump . com
s05nmdl2sm-rev0814
36
Torque:
70 in/lbs
DIAPHRAGM CONFIGURATION
DETAIL
NOTE TO ASSEMBLY
INLINE DISCHARGE
MANIFOLD OPTION
3: EXP VIEW
Torque:
50 in/lbs
Torque:
70 in/lbs
Torque:
120 in/lbs
Torque:
70 in/lbs
Torque:
50 in/lbs
MUFFLER OPTION
OVERLAY OPTION
INLINE DISCHARGE
MANIFOLD OPTION
35
476.202.354
IMPORTANT NOTE: Polypropylene pumps are shipped with the 1/2" NPT Pipe Plug (item 37) installed in the end ports of both suction and discharge
one-piece manifolds. To convert to the Inline porting positions for pump installation and operation, first remove the pipe plugs and re-install in the center
ports. Apply PTFE tape or pipe sealant to threads of the plug before installation.
sandpiperpump . com
s05nmdl2sm-rev0814
Description................................................................... Qty
Air Valve Assembly............................................................ 1
Air Valve Assembly (with PTFE Coated Hardware) .......... 1
Air Valve Assembly (with Conductive Polypropylene) ...... 1
Air Valve Assembly (with Stroke Indicator Pins) .............. 1
Air Valve Assembly ........................................................... 1
(with Stroke Indicator Pins and PTFE Coated Hardware)
Air Valve Assembly............................................................ 1
Air Valve Assembly, Conductive Polypropylene................ 1
Air Valve Assembly (no muffler with Stroke Indicator Pins)... 1
High Temperature.............................................................. 1
High Temperature, Conductive Polypropylene.................. 1
High Temperature.............................................................. 1
High Temperature, Conductive Polypropylene.................. 1
Ball, Check, Santoprene................................................... 4
Ball, Check, Polyurethane................................................ 4
Ball, Check, Nitrile............................................................. 4
Ball, Check, PTFE............................................................ 4
Pilot Valve Assembly........................................................ 1
Conductive Ploypropylene & Conductive PVDF Options....... 1
Bracket, Intermediate....................................................... 1
Bracket, Intermediate ....................................................... 1
Bracket, Mounting............................................................ 2
Bracket, Mounting............................................................. 2
Bumper, Diaphragm......................................................... 2
Bushing, Plunger............................................................... 2
Cap, Air Inlet..................................................................... 1
Cap, Air Inlet
.......................................... 1
Capscrew, Flanged 5/16-18 X 1.00................................... 8
Capscrew, Flanged 5/16-18 X 1.00................................... 8
Capscrew, Flanged 5/16-18 X 1.25................................. 24
Inline Option Only.............................................................. 8
Capscrew, Flanged 5/16-18 X 1.25................................. 24
Inline Option Only.............................................................. 8
Capscrew, Flanged 5/16-18 X 1.50................................ 12
Capscrew, Flanged 5/16-18 X 1.50................................. 12
Capscrew, Flanged 1/4-20 X 1.25.................................... 8
Capscrew, Flanged 1/4-20 X 1.25.................................... 8
Capscrew, Flanged 5/16-18 X .88..................................... 4
Capscrew, Flanged 5/16-18 X .88..................................... 4
Chamber, Outer, PVDF..................................................... 2
Chamber, Outer, Conductive PVDF.................................. 2
Chamber, Outer, Nylon...................................................... 2
Chamber, Outer, Poly........................................................ 2
Chamber, Outer, Conductive Poly..................................... 2
Diaphragm, Santoprene ................................................... 2
Diaphragm, Polyurethane.................................................. 2
Diaphragm, Nitrile.............................................................. 2
Diaphragm, One-Piece, PTFE........................................... 2
3: EXP VIEW
LEGEND:
= Items contained within Air End Kits
= Items contianed within Wet End Kits
Note: Kits contain components specific to the material codes.
ATEX Compliant
sandpiperpump . com
s05nmdl2sm-rev0814
MATERIAL CODES -
3: EXP VIEW
000
Assembly, sub-assembly;
and some purchased items
010 Cast Iron
015 Ductile Iron
020 Ferritic Malleable Iron
080 Carbon Steel, AISI B-1112
110 Alloy Type 316 Stainless Steel
111
Alloy Type 316 Stainless Steel
(Electro Polished)
112 Alloy C
113 Alloy Type 316 Stainless Steel
(Hand Polished)
114 303 Stainless Steel
115 302/304 Stainless Steel
117 440-C Stainless Steel (Martensitic)
120 416 Stainless Steel
(Wrought Martensitic)
148 Hardcoat Anodized Aluminum
150 6061-T6 Aluminum
152 2024-T4 Aluminum (2023-T351)
155 356-T6 Aluminum
156 356-T6 Aluminum
157 Die Cast Aluminum Alloy #380
158 Aluminum Alloy SR-319
162 Brass, Yellow, Screw Machine Stock
165 Cast Bronze, 85-5-5-5
166 Bronze, SAE 660
170 Bronze, Bearing Type,
Oil Impregnated
180 Copper Alloy
305 Carbon Steel, Black Epoxy Coated
306 Carbon Steel, Black PTFE Coated
307 Aluminum, Black Epoxy Coated
308 Stainless Steel, Black PTFE Coated
309 Aluminum, Black PTFE Coated
313 Aluminum, White Epoxy Coated
330 Zinc Plated Steel
332 Aluminum, Electroless Nickel Plated
333 Carbon Steel, Electroless
Nickel Plated
335 Galvanized Steel
337 Silver Plated Steel
351 Food Grade Santoprene
353 Geolast; Color: Black
354 Injection Molded #203-40
Santoprene Duro 40D +/-5;
Color: RED
356 Hytrel
357 Injection Molded Polyurethane
358 Urethane Rubber
(Some Applications)
(Compression Mold)
359 Urethane Rubber
360 Nitrile Rubber Color coded: RED
363 FKM (Fluorocarbon)
Color coded: YELLOW
364
E.P.D.M. Rubber
Color coded: BLUE
365 Neoprene Rubber
Color coded: GREEN
366 Food Grade Nitrile
368 Food Grade EPDM
371 Philthane (Tuftane)
374 Carboxylated Nitrile
375 Fluorinated Nitrile
378 High Density Polypropylene
379 Conductive Nitrile
408 Cork and Neoprene
425 Compressed Fibre
426 Blue Gard
440 Vegetable Fibre
500 Delrin 500
502 Conductive Acetal, ESD-800
503 Conductive Acetal, Glass-Filled
506 Delrin 150
520 Injection Molded PVDF
Natural color
540 Nylon
542 Nylon
544 Nylon Injection Molded
550 Polyethylene
551 Glass Filled Polypropylene
552 Unfilled Polypropylene
555 Polyvinyl Chloride
556 Black Vinyl
557 Unfilled Conductive Polypropylene
558 Conductive HDPE
559 Glass-Filled Conductive Polypropylene
570 Rulon II
580 Ryton
600 PTFE (virgin material)
Tetrafluorocarbon (TFE)
603 Blue Gylon
604 PTFE
606 PTFE
607 Envelon
608 Conductive PTFE
610 PTFE Encapsulated Silicon
611 PTFE Encapsulated FKM
632 Neoprene/Hytrel
633 FKM/PTFE
634 EPDM/PTFE
635 Neoprene/PTFE
637 PTFE, FKM/PTFE
638 PTFE, Hytrel/PTFE
639 Nitrile/TFE
643 Santoprene/EPDM
644 Santoprene/PTFE
656 Santoprene Diaphragm and
Check Balls/EPDM Seats
661 EPDM/Santoprene
666 FDA Nitrile Diaphragm,
RECYCLING
sandpiperpump . com
s05nmdl2sm-rev0814
Item
Part Number
1
031.166.000
1-A
095.106.551
1-B
031.132.000
1-C 560.101.360
1-E
165.122.551
1-F 560.026.360
1-G
675.062.115
1-H
530.031.550
1-I
165.109.551
1-J
710.011.115
IMPORTANT
Read these instructions completely, before installation
and start-up. It is the responsibility of the purchaser
to retain this manual for reference. Failure to comply
with the recommendations stated in this manual will
damage the pump, and void factory warranty.
ATEX Compliant
Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
End Cap
O-Ring
End Cap Retainer
Muffler
Muffler Cap
Self-Tapping Screw
s05nmdl2sm-rev0814
1
2
4
Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
End Cap
O-Ring
End Cap Retainer
Muffler
Muffler Cap
Self-Tapping Screw
Qty
1
1
1
8
2
2
2
1
1
4
1
1
1
1
1
1
(Includes all items used on 031.166.003 above minus 1.H, 1.I and 1.J)
031.195.000
031.175.000
sandpiperpump . com
Qty
1
1
1
8
2
2
2
1
1
4
4: AIR END
1-K
1-H
1-J
1-B
1-F
1-E
1-B
1-D
1-C
1-I
1-D
1-C
4: AIR END
1-F
1-A
1-E
1-G
Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
Bumper
End Cap
O-Ring
End Cap Retainer
Safety Clip
Muffler
Muffler Cap
Self-Tapping Screw
1
2
4
(Includes all items used on 031.167.000 above minus 1.H, 1.I and 1.J)
ATEX Compliant
11 Model S05 Non-Metallic
Qty
1
1
1
8
2
2
2
2
1
1
1
4
sandpiperpump . com
s05nmdl2sm-rev0814
replace if required.
Part Number
095.091.000
095.087.551
755.051.000
560.033.360
775.055.000
560.023.360
675.037.080
Description
Pilot Valve Assembly
Valve Body
Sleeve (With O-Rings)
O-Ring (Sleeve)
Spool (With O-Rings)
O-Ring (Spool)
Retaining Ring
Qty
1
1
1
6
1
3
1
4: AIR END
Part Number
095.091.001
095.087.558
755.051.000
560.033.360
775.055.000
560.023.360
675.037.080
Description
Pilot Valve Assembly
Pilot Valve Body
Sleeve (With O-Rings)
O-Ring (Sleeve)
Spool (With O-Rings)
O-Ring (Spool)
Retaining Ring
Qty
1
1
1
6
1
3
1
ATEX Compliant
sandpiperpump . com
s05nmdl2sm-rev0814
32
26
30
4: AIR END
29
Description
Bracket, Intermediate
Bracket, Intermediate
Bushing, Plunger
O-Ring
Plunger, Actuator
Ring, Retaining*
Seal, Diaphragm Rod
Qty
1
1
2
2
2
2
2
IMPORTANT
When the pumped product source is at a higher
level than the pump (flooded suction condition),
pipe the exhaust higher than the product source
to prevent siphoning spills. In the event of a
diaphragm failure a complete rebuild of the
center section is recommended.
sandpiperpump . com
s05nmdl2sm-rev0814
15
27
31
6
11
28
14
19
25
27
15
13
Diaphragm Orientation
14
Torque:
120 in/lbs
11
16
15
27
31
6
14
11
15
16
25
27
Torque:
120 in/lbs
13
Diaphragm Orientation
14
11
5: WET END
28
15
11
31
6
14
28
25
15
13
14
11
sandpiperpump . com
s05nmdl2sm-rev0814
Diaphragm Orientation
Install diaphragm as shown above.
DIAPHRAGM SERVICING
Step 1: With manifolds and outer chambers
removed, remove diaphragm assemblies from
diaphragm rod. DO NOT use a pipe wrench or similar
tool to remove assembly from rod. Flaws in the rod
surface may damage bearings and seal. Soft jaws
in a vise are recommended to prevent diaphragm
rod damage.
Step 1.A: NOTE: Not all inner diaphragm plates
are threaded. Some models utilize a though hole in
the inner diaphragm plate. If required to separate
diaphragm assembly, place assembly in a vice,
gripping on the exterior cast diameter of the inner
plate. Turn the outer plate clockwise to separate the
assembly.
Always inspect diaphragms for wear cracks or
chemical attack. Inspect inner and outer plates for
deformities, rust scale and wear. Inspect intermediate
bearings for elongation and wear. Inspect diaphragm
rod for wear or marks.
Clean or repair if appropriate. Replace as required.
Step 2: Reassembly: There are two different types
of diaphragm plate assemblies utilized throughout the
Sandpiper product line: Outer plate with a threaded
stud, diaphragm, and a threaded inner plate.
5: WET END
IMPORTANT
Read these instructions completely,
before installation and start-up.
It is the responsibility of the
purchaser to retain this manual for
reference. Failure to comply with
the recommendations stated in this
manual will damage the pump, and
void factory warranty.
sandpiperpump . com
s05nmdl2sm-rev0814
41
8
20
Wiring
Diagram
40
3rd Terminal
for ground.
#2 Terminal
Neutral
(Negative)
30
39
42
26
#1 Terminal
Power
(Positive)
26
42
30
12
4
22
38
(Includes all items used on Composite Repair Parts List except as shown)
Item
Part Number
4
114.023.551
38
893.099.000
39
219.001.000
219.004.000
219.002.000
219.003.000
40
241.001.000
241.003.000
41
171.065.115
42
618.050.150
The Solenoid Shifted pump has a solenoid operated, air distribution valve in
place of the standard pilot operated, air distribution valve. Where a pilot valve
is normally utilized to cycle the pumps air distribution valve, an electric solenoid
is utilized. The solenoid coil is connected to a customer-supplied control. As the
solenoid is powered, one of the pumps air chambers is pressurized while the
other chamber is exhausted. When electric power is turned off, the solenoid
shifts and the pressurized chamber is exhausted while the other chamber
is pressurized. By alternately applying and removing power to the solenoid,
the pump cycles much like a standard pump, with one exception. This option
provides a way to precisely control and monitor pump speed.
s05nmdl2sm-rev0814
sandpiperpump . com
4
2
6: OPTIONAL
39
A fuse corresponding to its rated current (max. 3*I according IEC 60127.2.1) or a
motor protecting switch with short-circuit and thermal instantaneous tripping (set to
rated current) shall be connected in series to each solenoid as short circuit protection.
For very low rated currents of the solenoid the fuse of lowest current value according
to the indicated IEC standard will be sufficient. The fuse may be accommodated in the
associated supply unit or shall be separately arranged. The rated voltage to the fuse
shall be equal to or greater than the stated rated voltage of the magnet coil. The
breakage capacity of the fuse-link shall be as high as or higher than the maximum
expected short circuit current at the location of the installation (usually 1500 A). A
maximum permissible ripple of 20% is valid for all magnets of direct-current design.
Qty
1
1
1
1
1
1
1
1
IEC EEX m T4
BEFORE INSTALLATION
rat
Description
Bracket, Intermediate
Solenoid Valve, NEMA4
Solenoid Coil, 24VDC
Solenoid Coil, 24VAC/12VDC
Solenoid Coil, 120VAC
Solenoid Coil, 240VAC
Connector, conduit
Conduit Connector with
Suppression Diode (DC Only)
Capscrew, Flanged 1/4.20 x 1.00
Plug (Replaces Item 7)
II 2D c IP65 T100C
For ATEX Compliant Solenoid Coils used in the European Union
1
39 219.011.001 Solenoid Coil, Single mounting 12 VDC, 3.3W / 267mA
219.011.002 Solenoid Coil, Single mounting 24 VDC, 3.3W / 136mA
1
219.011.003 Solenoid Coil, Single mounting 110/120 VAC, 3.4W / 29mA 1
219.011.004 Solenoid Coil, Single mounting 220/240 VAC, 3.4W / 15mA 1
37
38
Illustration for Dual Port Suction and Single or Dual Port Discharge
*Dual suction/dual discharge = no manifold.
6: OPTIONAL
Item
10*
11*
17
18
25*
37
38
Part Number
Description
171.063.115
Capscrew, Flanged 5/16-18 x 1.25
171.063.308
Capscrew, Flanged 5/16-18 x 1.25
171.064.115
Capscrew, Flanged HD 5/16-18 X 1.50
171.064.308
Capscrew, Flanged HD 5/16-18 X 1.50
312.106.520N
Elbow, " NPT (replaces 312.106.520)
312.106.521N
Elbow, " NPT (replaces 312.106.521)
312.106.542N
Elbow, " NPT (replaces 312.106.542)
312.106.552N
Elbow, " NPT (replaces 312.106.552)
312.106.557N
Elbow, " NPT (replaces 312.106.557)
312.112.520N
Elbow, " NPT (replaces 312.112.520)
312.112.521N
Elbow, " NPT (replaces 312.112.521)
312.112.542N
Elbow, " NPT (replaces 312.112.542)
312.112.552N
Elbow, " NPT (replaces 312.112.552)
312.112.557N
Elbow, " NPT (replaces 312.112.557)
544.005.115
Nut, Flanged 5/16-18
544.005.308
Nut, Flanged 5/16-18
115.144.305
Bracket, Free Standing (replaces 115.140.115)
115.144.306
Bracket, Free Standing (replaces 115.140.115)
171.068.115
Capscrew, Flanged 5/16-18 X 1.63
171.068.308
Capscrew, Flanged 5/16-18 X 1.63
*Hardware quantities are variable based on porting configurations
Qty
8
8
4
4
2
2
2
2
2
2
2
2
2
2
20
20
2
2
8
8
ATEX Compliant
IMPORTANT
Read these instructions completely, before
installation and start-up. It is the responsibility
of the purchaser to retain this manual
for reference. Failure to comply with the
recommendations stated in this manual will
damage the pump, and void factory warranty.
sandpiperpump . com
s05nmdl2sm-rev0814
Written Warranty
Declaration of Conformity
David Roseberry
Printed name of authorized person
Engineering Manager
Title
Revision Level: F
7: WARRANTY
EC Declaration of Conformity
In accordance with ATEX Directive 94/9/EC,
Equipment intended for use in potentially explosive environments.
Manufacturer: Warren Rupp, Inc., A Unit of IDEX Corportion
800 North Main Street, P.O. Box 1568, Mansfield, OH 44902 USA
EN 60079-25: 2011
For pumps equipped with Pulse Output ATEX Option
Quality B.V. (0344)
Applicable Standard:
EN13463-1: 2009
EN13463-5: 2011
DATE/APPROVAL/TITLE:
14 MAY 2014
EC Declaration of Conformity
DATE/APPROVAL/TITLE:
27 MAY 2010
Type
Marking
Listed In
No
Yes
Yes
II 2 G EEx m c II T5
II 3/2 G EEx m c II T5
II 2 D c IP65 T100oC
No
Yes
Yes
II 1 G c T5
II 3/1 G c T5
II 1 D c T100oC
I M1 c
I M2 c
No
Yes
Yes
No
Yes
II 2 G c T5
II 3/2 G c T5
II 2 D c T100oC
No
Yes
Yes
II 2 G T5
II 3/2 G T5
II 2 D T100oC
Applicable Standard:
EN13463-1: 2001,
EN13463-5: 2003
EC Declaration of Conformity
7: WARRANTY
Non-Conductive
Fluids
KEMA 09ATEX0073
CE
KEMA 09ATEX0073
KEMA 09ATEX0073
KEMA 09ATEX0073
No
Yes
Yes