s05nmdl2sm PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

Original Instructions

Certified Quality

Model S05

3: EXP VIEW

2: INSTAL & OP

Non-Metallic
Design Level 2

1: PUMP SPECS

SERVICE & OPERATING MANUAL

TROP EGR
T

4: AIR END

Quality System
ISO 9001 Certified

TELNI
TPNF

5: WET END

Environmental Management System


ISO 14001 Certified

6: OPTIONAL

831

Warren Rupp, Inc.

7: WARRANTY

A Unit of IDEX Corporation


800 N. Main St.,
Mansfield, Ohio 44902 USA
Telephone 419.524.8388
Fax 419.522.7867
SANDPIPERPUMP.COM

Copyright 2014 Warren Rupp, Inc.


All rights reserved

dnuoS & hseM


getnI dradnatS
relffuM gnines
pm
Dd plainrp
aan
oe
itprOpru
elfm
fup
M. c o m
noitpO

Safety Information
IMPORTANT

WARNING
When used for toxic or aggressive fluids, the pump should
always be flushed clean prior to disassembly.

Read the safety warnings and instructions in this manual


before pump installation and start-up. Failure to comply with
the recommendations stated in this manual could damage the
pump and void factory warranty.

Before maintenance or repair, shut off the compressed air line,


bleed the pressure, and disconnect the air line from the pump.
Be certain that approved eye protection and protective clothing
are worn at all times. Failure to follow these recommendations
may result in serious injury or death.

When the pump is used for materials that tend to settle out
or solidify, the pump should be flushed after each use to
prevent damage. In freezing temperatures the pump should be
completely drained between uses.

Airborne particles and loud noise hazards. Wear eye and ear
protection.

CAUTION

In the event of diaphragm rupture, pumped material may enter


the air end of the pump, and be discharged into the atmosphere.
If pumping a product that is hazardous or toxic, the air exhaust
must be piped to an appropriate area for safe containment.

Before pump operation, inspect all fasteners for loosening


caused by gasket creep. Retighten loose fasteners to prevent
leakage. Follow recommended torques stated in this manual.

Take action to prevent static sparking. Fire or explosion can


result, especially when handling flammable liquids. The pump,
piping, valves, containers and other miscellaneous equipment
must be properly grounded.

Nonmetallic pumps and plastic components are not UV


stabilized. Ultraviolet radiation can damage these parts and
negatively affect material properties. Do not expose to UV light
for extended periods of time.

This pump is pressurized internally with air pressure during


operation. Make certain that all fasteners are in good condition
and are reinstalled properly during reassembly.

WARNING
Pump not designed, tested or certified to be powered by
compressed natural gas. Powering the pump with natural
gas will void the warranty.

Use safe practices when lifting


kg

Grounding the Pump

To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.
Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.
To reduce the risk of static electrical sparking, this pump must be grounded. Check the local
electrical code for detailed grounding instruction and the type of equipment required.
Refer to nomenclature page for ordering information.

WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or
other miscellaneous equipment must
be grounded.

Model S05 Non-Metallic

sandpiperpump . com
s05nmdl2sm-rev0814

SECTION 5: WET END......................................14



Diaphragm Drawing

Diaphragm Servicing
SECTION 6: OPTIONAL CONFIGURATIONS.....16

Solenoid Shifted Air Valve

Dual Port
SECTION 7: WARRANTY & CERTIFICATES.....18

Warranty

CE Declaration of Conformity - Machinery

ATEX Declaration of Conformity

Explanation of ATEX Certifications

sandpiperpump . com
s05nmdl2sm-rev0814

2: INSTAL & OP
3: EXP VIEW
4: AIR END

SECTION 4: AIR END........................................10



Air Distribution Valve Assembly

Air Valve with Stroke Indicator Option

Pilot Valve

Intermediate Assembly

5: WET END

SECTION 3: EXPLODED VIEW............................7



Composite Drawings

Parts List

Materials Code

6: OPTIONAL

SECTION 2: INSTALLATION & OPERATION.......4



Principle of Pump Operation

Typical Installation Guide

Troubleshooting

7: WARRANTY

SECTION 1: PUMP SPECIFICATIONS.................1



Nomenclature

Performance

Materials

Dimensional Drawings

1: PUMP SPECS

Table of Contents

Model S05 Non-Metallic

1: PUMP SPECS

Explanation of Pump Nomenclature


Your Model
S
#: __
____
__ __ __ __ __ __ __ __ __
____
(fill in from pump
nameplate)

Pump
Brand

Model
#:

Pump
Size

Check
Valve

Wetted Diaphragm/ Check Valve Non-Wetted Porting


Material Check Valves
Seat
Material Options

Pump
Style

Pump
Options

Kit
Options

S XX X X X X X X X X X XX

Pump Brand

S SANDPIPER

Pump Size
05 1/2"

Check Valve Type


B Soilid Ball

Design Level
2

Design
Level

Design Level

Wetted Material

K PVDF
N Nylon
P Polypropylene
C Conductive Polypropylene
V Conductive PVDF

Diaphragm/Check Valve Materials


1 Santoprene/Santoprene
2 Virgin PTFE/Santoprene

Backup/Virgin PTFE
B Nitrile/Nitrile
U Polyurethane/Polyurethane
Z One-Piece Bonded/PTFE

Check Valve Seat

Kit Options

00. None
P0. 10.30VDC Pulse Output Kit
P1. Intrinsically-Safe 5.30VDC,

110/120VAC 220/240 VAC

Pulse Output Kit
P2. 110/120 or 220/240VAC

Pulse Output Kit
E0. Solenoid Kit with 24VDC Coil
E1. Solenoid Kit with 24VDC

Explosion-Proof Coil
E2. Solenoid Kit with 24VAC/12VDC Coil
E3. Solenoid Kit with 12VDC

Explosion-Proof Coil
E4. Solenoid Kit with 110VAC Coil
E5. Solenoid Kit with 110VAC

Explosion-Proof Coil
E6. Solenoid Kit with 220VAC Coil
E7. Solenoid Kit with 220VAC

Explosion-Proof Coil
E8. Solenoid Kit with 110VAC, 50 Hz

Explosion-Proof Coil
E9. Solenoid Kit with 230VAC, 50 Hz

Explosion-Proof Coil
SP. Stroke Indicator Pins

S Stainless Steel
T Virgin PTFE

Non-Wetted Material Options


P Polypropylene
1 Polypropylene w/PTFE Coated
Hardware
C Conductive Polypropylene

Porting Options
N
B
1
2
3
4
5
6

NPT Threads
BSP (Tapered) Threads
Dual Porting (NPT)
Top Dual Porting (NPT)
Bottom Dual Porting (NPT)
Dual Porting (BSP Tapered)
Top Dual Porting (BSP Tapered)
Bottom Dual Porting (BSP Tapered)

Pump Style

S Standard
I Inline Porting NPT Threads

Pump Options

0 None
1 Sound Dampening Muffler
2 Mesh Muffler
6 Metal Muffler
7 Metal Muffler with Grounding Cable

A1. Solenoid Kit with 12 VDC



ATEX Compliant Coil
A2. Solenoid Kit with 24 VDC

ATEX Compliant Coil
A3. Solenoid Kit with 110/120 VAC

50/60 Hz ATEX Compliant Coil
A4. Solenoid Kit with 220/240 VAC

50/60 Hz ATEX Compliant Coil

Your Serial #: (fill in from pump nameplate)______________________________________

ATEX Detail
(1)

(2)

II 1G c T5
IIII 2GD
3/1 GT5c T5
II 1D c T100C
I M1 c
I M2 c
Note: Pumps are only ATEX compliant when ordered with
wetted material option C or V, Non-wetted material
option C, pump option 0, 6 or 7, and kit option 0.
II 2G
2G Ex
Ex ia
ia cc IIC
IICT5
T5
II
II 2D
3/2 cGiaD
Ex 20
ia cIP67
IIC T100C
T5
II

II 2D Ex c ia 20 IP67 T100C

Note: Pumps ordered with the options listed in (1) are ATEX
compliant when ordered with kit option P1.

(3)

(4)

2G EEx
EExmmccT5
II T5
IIII 2G
3/2c2G
EEx
m c II T5
IIII 2D
IP65
T100C

II 2D c IP65 T100C
Note: Pumps ordered with the options listed in (1) are ATEX
compliant when ordered with kit option A1, A2, A3, or A4.
Compressed Air Temperature Range: Maximum Ambient
Temperature to plus 50C.

IEC EEX m T4

Note: Pump models equipped with these explosion-proof solenoid


kit options E1, E3, E5, E7, E8 or E9, are certified and approved by
the above agencies. They are NOT ATEX compliant.

Special condition for safe use:


Conductive polypropylene, conductive acetal, or conductive PVDF pumps are not to be installed
in applications where the pumps may be subjected to oil, greases and hydraulic liquids.

1 Model S05 Non-Metallic

sandpiperpump . com
s05nmdl2sm-rev0814

Performance
S05 NON-METALLIC

HEADS UP TO
100 psi or 231 ft. of water
(7 bar or 70 meters)
DISPLACEMENT/STROKE
.026 Gallon / .098 liter

0P

80

70
60

SI

12 (20)

Bar

14 (24)

2 Bar

20 PS

I (1.3

16 (27)

ar)

I (2.7

10
0

8 (13.5)

.08 B

40 PS

30

.44

SI (4

20
1

ar)

I (5

60 P

40

6 (10)

8B

10 (17)

PS

50
3

4 (7)

(6.

6 Bar)

Air Inlet

Pressure

10

SHIPPING WEIGHT
Polypropylene 16 lbs. (8kg)
PVDF 18 lbs. (9kg)

NPSHR

90
80

1: PUMP SPECS

PSI

10

10

11

U.S. Gallons per minute

20

30

Liters per minute


CAPACITY

40

12

13

14

50

15

METERS

SOLIDS-HANDLING
Up to .125 in. (3mm)

2 (3.5)

7 100
6

HEAD

AIR DISTRIBUTION VALVE


No-lube, no-stall design

Performance based on the following: elastomer fitted pump, flooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.

FEET

CAPACITY
0 to 14 gallons per minute
(0 to 52 liters per minute)

MODEL S05 Non-Metallic Performance Curve

BAR

SUCTION/DISCHARGE PORT SIZE


1/2" NPT (Internal) or 1/2" BSP (Tapered)
1" NPT (External) or 1" BSP (Tapered)

30
25
20
15
10
5

9.1
7.6
6
4.5
3
1.5

16

60

Materials
Material Profile:

Operating
Temperatures:

CAUTION! Operating temperature limitations are as follows:

Max.

Min.

Conductive Acetal: Tough, impact resistant, ductile. Good


abrasion resistance and low friction surface. Generally inert, with
good chemical resistance except for strong acids and oxidizing
agents.

190F
88C

-20F
-29C

EPDM: Shows very good water and chemical resistance. Has


poor resistance to oils and solvents, but is fair in ketones and
alcohols.

280F
138C

-40F
-40C

FKM: (Fluorocarbon) Shows good resistance to a wide range


of oils and sovents; especially all aliphatic, aromatic and
halogenated hydrocarbons, acids, animal and vegetable oils.
Hot water or hot aqueous solutions (over 70F) will attack FKM.

350F
177C

-40F
-40C

Hytrel: Good on acids, bases, amines and glycols at room


temperatures only.

220F
104C

-20F
-29C

Neoprene: All purpose. Resistance to vegetable oils. Generally


not affected by moderate chemicals, fats, greases and many
oils and solvents. Generally attacked by strong oxidizing acids,
ketones, esters and nitro hydrocarbons and chlorinated aromatic
hydrocarbons.

200F
93C

-10F
-23C

Nitrile: General purpose, oil-resistant. Shows good solvent, oil,


water and hydraulic fluid resistance. Should not be used with
highly polar solvents like acetone and MEK, ozone, chlorinated
hydrocarbons and nitro hydrocarbons.

190F
88C

-10F
-23C

Nylon: 6/6 High strength and toughness over a wide


temperature range. Moderate to good resistance to fuels, oils
and chemicals.

180F
82C

32F
0C

Polypropylene: A thermoplastic polymer. Moderate tensile


and flex strength. Resists stong acids and alkali. Attacked by
chlorine, fuming nitric acid and other strong oxidizing agents.

180F
82C

32F
0C

PVDF: (Polyvinylidene Fluoride) A durable fluoroplastic with


excellent chemical resistance. Excellent for UV applications.
High tensile strength and impact resistance.

250F
121C

0F
-18C

Santoprene: Injection molded thermoplastic elastomer with


no fabric layer. Long mechanical flex life. Excellent abrasion
resistance.

275F
135C

-40F
-40C

UHMW PE: A thermoplastic that is highly resistant to a broad


range of chemicals. Exhibits outstanding abrasion and impact
resistance, along with environmental stress-cracking resistance.

180F
82C

-35F
-37C

Urethane: Shows good resistance to abrasives. Has poor


resistance to most solvents and oils.

150F
66C

32F
0C

Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious.


Very few chemicals are known to chemically react with PTFE;
molten alkali metals, turbulent liquid or gaseous fluorine and
a few fluoro-chemicals such as chlorine trifluoride or oxygen
difluoride which readily liberate free fluorine at elevated
temperatures.

220F
104C

-35F
-37C

Maximum and Minimum Temperatures are the limits for which these materials can be operated.
Temperatures coupled with pressure affect the longevity of diaphragm pump components.
Maximum life should not be expected at the extreme limits of the temperature ranges.

Metals:
Alloy C: Equal to ASTM494 CW-12M-1 specification for nickel and nickel alloy.
Stainless Steel: Equal to or exceeding ASTM specification A743 CF-8M for corrosion
resistant iron chromium, iron chromium nickel and nickel based alloy castings for
general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.

For specific applications, always consult the Chemical Resistance Chart.


Ambient temperature range -20 C to +40 C
Process temperature range -20 C to +80 C for models rated as category 1 equipment

-20 c to +100 C for model rated as category 2 equipment
In addition, the ambient temperature range and the process temperature range do not exceed the operating temperature range of the applied non-metallic parts as listed in the manuals of the pumps.

sandpiperpump . com
s05nmdl2sm-rev0814

Model S05 Non-Metallic 2

DISCHARGE PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)

10.11 257

A
1.48

3.07 78
1.75 44

MANIFOLD CAN ROTATE 90


FROM VERTICAL CENTERLINE

AIR INLET
1/4 FNPT

S05 Non-Metallic Center Ported Options

11.54 293

MANIFOLD CAN ROTATE 90


FROM VERTICAL CENTERLINE

1: PUMP SPECS

Dimensions in inches (metric dimensions in brackets). Dimensional


Tolerance .125" (3mm).
1.48

9.79 249
DISCHARGE PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)

AIR INLET
10.11 257
1/4 FNPT

A
3.07 78

5.45 138

1.75 44
MANIFOLD CAN ROTATE 90
FROM VERTICAL CENTERLINE

1.38 35

AIR INLET
1/4 FNPT

9.79 249
SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)

STANDARD INTEGRAL MUFFLER


6.56 167

9.79 249

.07 2

1.75 44

5.45 138

4X .36 9
MTG. SLOT
11.54 293

1.38 35

AIR INLET
1/4 FNPT
Mesh & Sound
Standard Integral
Dampening Muffler
Muffler Option
Option

S05 NON-METALLIC
CENTER PORTED OPTION

5.45 138

DIMENSIONAL TOLERANCE = .125 [3mm]

SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)

ER

1.48

6.56 167 3.63 92

7.13 [181]

8.81 [224]

9.79 249

.07 2

1.75 44

GENERAL NOTES

.07 2

1.

OPTIONAL SUCTION & DISCHARGE PORTS AVAILABLE IN 1" BSP


(INTERNAL) AND 1" BSP (EXTERNAL)

2.

Mesh & Sound


Standard
Integral
STANDARD INTEGRAL MUFFLER
(SHOWN)
COVERS
3/8" FNPT EXHAUST

5.45 138

Dampening Muffler 1.38 35


Muffler Option
PORT FOR OPTIONAL MUFFLER STYLES
OR PIPINGOption
EXHAUST AIR IN
S05 NON-METALLIC
SUBMERGED APPLICATIONS

CENTER PORTED OPTION

DIMENSIONAL TOLERANCE = .125 [3mm]


STANDARD INTEGRAL MUFFLER
Mesh & Sound
Standard Integral Dampening Muffler
Muffler Option
Option

ALLIC

OPTION

.125 [3mm]

7.13 [181]

8.81 [224]

2.

8.81 [224]
1.75 44

.07 2

6.56 167

GENERAL NOTES
1.

7.13 [181]

SUCTION PORT
1/2" FNPT (INTERNAL)
1" MNPT (EXTERNAL)

4X .36 9
OPTIONAL SUCTION & MTG.
DISCHARGE
SLOT PORTS AVAILALBE IN 1" BSP

(INTERNAL) AND 1" BSP (EXTERNAL)

PART NUMBER

M
Standard Integral Da
Muffler Option

S05 NON-METALLIC

STANDARD INTEGRAL MUFFLER (SHOWN) COVERS 3/8" FNPT EXHAUST


PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN
SUBMERGED APPLICATIONS

CENTER PORTED OPTION

A
DIMENSIONAL TOLERANCE
= .125 [3mm]

MADE FROM

TOLERANCES

MATERIAL

S05 Non-Metallic Inline Ported Options - (Polypropylene Wet End Models Only)
3.63 92

PORTS AVAILABLE IN 1" BSP


)

.XX
.XXX

Dimensions in inches (metric dimensions in brackets). Dimensional Tolerance .125"


(3mm).
S05 NON-METALLIC

HOWN) COVERS
3/8" FNPT EXHAUST6
7
YLES OR PIPING EXHAUST AIR IN

D.1

REVISED DRAWING

MF

4/23/2010

REV

REVISION

CHG

DATE

PUMP REFERENCE

APP

DATE

DESCRIPTION

1/2

SURFACE FINSH

ASS'Y REFERENCE

ECN

THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOSE


WITHOUT
THE EXPRESS NOTES
WRITTEN PERMISSION OF IDEX AODD
GENERAL

.010
.005

ANGULAR

OUTLINE, PUMP, S05, CENTER PORTED

1.

63

DRAWING NUMBER

OPTIONAL SUCTION &REV


DISCHARGE PORTS AVAILABLE IN 1" BSP
(INTERNAL) AND 1" BSP (EXTERNAL)

D.1
450.319.001
2.
STANDARD INTEGRAL MUFFLER (SHOWN) COVERS 3/8" FNPT EXHAUST

DO NOT SCALE DRAWING


DIMENSIONS ARE INCHES

SHEET 1 of 2

PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN


SUBMERGED APPLICATIONS

DISCHARGE PORT (OPTIONAL)


1/2" FNPT

3.04 77
2X 1.75 44

11.76 299

DISCHARGE PORT
1/2" FNPT

AIR INLET
1/4 FNPT

10.62 270
9.79 249

5.45 138
1.38 35

SUCTION PORT
1/2" FNPT

STANDARD INTEGRAL MUFFLER


4X .38 10
MTG. HOLE

SUCTION PORT (OPTIONAL)


1/2" FNPT

.38 10

6.16 157
4X .31 8
MTG. SLOT
Mesh & Sound
Standard Integral Dampening
Muffler
Muffler Option
Option

S05 NON-METALLIC
IN-LINE PORTED OPTION

DIMENSIONAL TOLERANCE = .125 [3mm]

7.13 [181]

4.88 124

3.63 92

GENERAL NOTES
1.

OPTIONAL SUCTION & DISCHARGE SIDE PORTS WILL BE PLUGGED AT


FACTORY, NOT SHOWN

2.

STANDARD INTEGRAL MUFFLER (SHOWN) COVERS 3/8" FNPT EXHAUST


PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN
SUBMERGED APPLICATIONS

6.56 167

3 Model S05 Non-Metallic

7.13 [181]

IDEX AODD

UNLESS OTHERWISE
SPECIFIED

sandpiperpump . com
s05nmdl2sm-rev0814

8.81 [224]

Principle of Pump Operation


Air-Operated Double Diaphragm (AODD) pumps are powered
by compressed air or nitrogen.

As inner chamber pressure (P1) exceeds liquid chamber


pressure (P2), the rod connected diaphragms shift
together creating discharge on one side and suction on the
opposite side. The discharged and primed liquids directions
are controlled by the check valves (ball or flap) orientation.

Air Line
Discharged
Fluid

2: INSTAL & OP

The main directional (air) control valve distributes


compressed air to an air chamber, exerting uniform pressure
over the inner surface of the diaphragm . At the same time,
the exhausting air from behind the opposite diaphragm
is directed through the air valve assembly(s) to an exhaust
port .

The pump primes as a result of the suction stroke. The


suction stroke lowers the chamber pressure (P3) increasing
the chamber volume. This results in a pressure differential
necessary for atmospheric pressure (P4) to push the fluid
through the suction piping and across the suction side check
valve and into the outer fluid chamber .
Discharge
Stroke

Suction
Stroke

Primed
Fluid

PUMP INSTALLATION AREA

SAFE AIR
Suction (side) stroking also initiates the reciprocating
EXHAUST
(shifting, stroking or cycling) action of the pump.DISPOSAL
The suction
AREA its
diaphragms movement is mechanically pulled through
stroke.
1" DIAMETER
AIR The diaphragms inner plate makes contact with an
EXHAUST PIPING
actuator plunger aligned to shift the pilot signaling valve.
Once actuated, the pilot valve sends a pressureMUFFLER
signal to the
opposite end of the main directional air valve, redirecting the
compressed air to the opposite inner chamber.

SUBMERGED ILLUSTRATION
MUFFLER

LIQUID
LEVEL

1" DIAMETER AIR


EXHAUST PIPING

SUCTION
LINE

Pump can be submerged if the pump materials of construction


are compatible with the liquid being pumped. The air exhaust
must be piped above the liquid level. When the MUFFLER
pumped product
source is at a higher level than the pump (flooded suction
condition), pipe the exhaust higher than the product source to
prevent siphoning spills.
LIQUID
LEVEL

sandpiperpump . com
s05nmdl2sm-rev0814

SUCTION
LINE

1" DIAMETER AIR


EXHAUST PIPING

Model S05 Non-Metallic 4

Recommended Installation Guide


Available Accessories:
1. Surge Suppressor
2. Filter/Regulator
3. Air Dryer

Unregulated Air
Supply to Surge
Suppressor

Surge Suppressor

2: INSTAL & OP

Pressure Gauge

Shut-Off Valve

Note: Surge Suppressor and


Piping must be supported after
the flexible connection.

Pipe Connection
(Style Optional)
Flexible Connector

Discharge

Check
Valve

Muffler
(Optional Piped Exhaust)

Shut-Off
Valve

Drain Port

Flexible Connector
Vacuum
Gauge

Air Inlet

3
Filter Regulator
P/N: 020.V107.000
Air Dryer

Suction

CAUTION
Shut-Off Valve

The air exhaust should


be p iped to an area
for safe d isposition
of the product b eing
pumped, in the event of
a diaphragm failure.

Drain Port

Installation And Start-Up


Locate the pump as close to the product being pumped as possible. Keep the suction line length and number of fittings to a minimum. Do not reduce the suction line
diameter.
Air Supply
Connect the pump air inlet to an air supply with sufficient capacity and pressure to achieve desired performance. A pressure regulating valve should be installed to
insure air supply pressure does not exceed recommended limits.
Air Valve Lubrication
The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator
set to deliver one drop of SAE 10 non-detergent oil for every 20 SCFM (9.4 liters/sec.) of air the pump consumes. Consult the Performance Curve to determine air
consumption.
Air Line Moisture
Water in the compressed air supply may cause icing or freezing of the exhaust air, causing the pump to cycle erratically or stop operating. Water in the air supply can
be reduced by using a point-of-use air dryer.
Air Inlet And Priming
To start the pump, slightly open the air shut-off valve. After the pump primes, the air valve can be opened to increase air flow as desired. If opening the valve
increases cycling rate, but does not increase the rate of flow, cavitation has occurred. The valve should be closed slightly to obtain the most efficient air flow to pump
flow ratio.

5 Model S05 Non-Metallic

sandpiperpump . com
s05nmdl2sm-rev0814

Troubleshooting Guide
Pump Cycles Once

Pump Will Not Operate


/ Cycle

Pump Cycles and Will


Not Prime or No Flow

Potential Cause(s):

Deadhead (system pressure meets or exceeds air


supply pressure).
Air valve or intermediate gaskets installed incorrectly.
Bent or missing actuator plunger.
Pump is over lubricated.
Lack of air (line size, PSI, CFM).
Check air distribution system.
Discharge line is blocked or clogged manifolds.
Deadhead (system pressure meets or exceeds air
supply pressure).
Blocked air exhaust muffler.
Pumped fluid in air exhaust muffler.
Pump chamber is blocked.
Cavitation on suction side.
Check valve obstructed. Valve ball(s) not seating
properly or sticking.

Product Leaking
Through Exhaust

Valve ball(s) missing (pushed into chamber or


manifold).
Valve ball(s)/seat(s) damaged or attacked by product.
Check valve and/or seat is worn or needs adjusting.
Suction line is blocked.
Excessive suction lift.
Suction side air leakage or air in product.
Pumped fluid in air exhaust muffler.
Over lubrication.
Icing.
Clogged manifolds.
Deadhead (system pressure meets or exceeds air
supply pressure).
Cavitation on suction side.
Lack of air (line size, PSI, CFM).
Excessive suction lift.
Air supply pressure or volume exceeds system hd.
Undersized suction line.
Restrictive or undersized air line.
Suction side air leakage or air in product.
Suction line is blocked.
Pumped fluid in air exhaust muffler.
Check valve obstructed.
Check valve and/or seat is worn or needs adjusting.
Entrained air or vapor lock in chamber(s).
Diaphragm failure, or diaphragm plates loose.
Diaphragm stretched around center hole or bolt holes.

Premature Diaphragm
Failure

Cavitation.
Excessive flooded suction pressure.

Pump Cycles Running


Sluggish/Stalling,
Flow Unsatisfactory

Misapplication (chemical/physical incompatibility).

Unbalanced Cycling

Incorrect diaphragm plates or plates on backwards,


installed incorrectly or worn.
Excessive suction lift.
Undersized suction line.
Pumped fluid in air exhaust muffler.
Suction side air leakage or air in product.
Check valve obstructed.
Check valve and/or seat is worn or needs adjusting.
Entrained air or vapor lock in chamber(s).

Recommendation(s):

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Install gaskets with holes properly aligned.
Remove pilot valve and inspect actuator plungers.
Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Check the air line size and length, compressor capacity (HP vs. CFM required).
Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators.
Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Remove muffler screen, clean or de-ice, and re-install.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Disassemble and inspect wetted chambers. Remove or flush any obstructions.
Check suction condition (move pump closer to product).
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged.
Use heavier valve ball material.
Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical
Resistance Guide for compatibility.
Check Chemical Resistance Guide for compatibility.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Remove or flush obstruction. Check and clear all suction screens or strainers.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Visually inspect all suction-side gaskets and pipe connections.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Remove muffler screen, de-ice, and re-install. Install a point of use air drier.
Clean manifolds to allow proper air flow
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.
(Does not apply to high pressure 2:1 units).
Check suction (move pump closer to product).
Check the air line size, length, compressor capacity.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling.
Meet or exceed pump connections.
Install a larger air line and connection.
Visually inspect all suction-side gaskets and pipe connections.
Remove or flush obstruction. Check and clear all suction screens or strainers.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous.
Replace diaphragms, check for damage and ensure diaphragm plates are tight.
Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility
with products, cleaners, temperature limitations and lubrication.
Enlarge pipe diameter on suction side of pump.
Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.
Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations
and lubrication.
Check Operating Manual to check for correct part and installation. Ensure outer plates have not been
worn to a sharp edge.
For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases.
Meet or exceed pump connections.
Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Visually inspect all suction-side gaskets and pipe connections.
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Inspect check valves and seats for wear and proper setting. Replace if necessary.
Purge chambers through tapped chamber vent plugs.

2: INSTAL & OP

Symptom:

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

sandpiperpump . com
s05nmdl2sm-rev0814

Model S05 Non-Metallic 6

Composite Repair Parts Drawing


ILLUSTRATION SHOWS
DIRECTION OF DIAPHRAGMS

36
Torque:
70 in/lbs

DIAPHRAGM CONFIGURATION
DETAIL
NOTE TO ASSEMBLY

THE DIAPHRAGMS FOR BOTH


CONFIGURATIONS SHOWN ABOVE ARE TO BE
INSTALLED WITH CONVOLUTIONS FACING
TOWARDS CENTER OF PUMP

INLINE DISCHARGE
MANIFOLD OPTION

3: EXP VIEW

Torque:
50 in/lbs

Torque:
70 in/lbs
Torque:
120 in/lbs
Torque:
70 in/lbs

Torque:
50 in/lbs

MUFFLER OPTION

OVERLAY OPTION
INLINE DISCHARGE
MANIFOLD OPTION

35

Service & Repair Kits


476.219.000 AIR END KIT

Seals, O-Ring, Gaskets, Retaining Rings, Air Valve

Assembly and Pilot Valve Assembly.
476.220.000 AIR END KIT (Air Valve with Stroke Indicator Pin)

Seals, O-Ring, Gaskets, Retaining Rings, Air Valve

Assembly Pilot Valve Assembly.
476.202.360 WET END KIT

Nitrile Diaphragms, Nitrile Check Balls, PTFE

Seats and PTFE Seals.
476.202.365 WET END KIT

Neoprene Diaphragms, Neoprene Check Balls,

PTFE Seats and PTFE Seals.

476.202.354


WET END KIT


Santoprene Diaphragms, Nitrile Spacer Gaskets,
Santoprene Check Balls, PTFE Seats and
PTFE Seals.

476.202.357 WET END KIT



Polyurethane Diaphragms, Nitrile Spacer Gaskets,

Santoprene Check Balls, PTFE Seats and PTFE Seals.
476.202.654


WET END KIT


Santoprene Diaphragms, PTFE Overlay
Diaphragm, PTFE Check Balls, PTFE Seats
and PTFE Seals.

476.202.659 WET END KIT



One-Piece Bonded PTFE/Nitrile Diaphragm,

PTFE Balls, PTFE Seats.

IMPORTANT NOTE: Polypropylene pumps are shipped with the 1/2" NPT Pipe Plug (item 37) installed in the end ports of both suction and discharge
one-piece manifolds. To convert to the Inline porting positions for pump installation and operation, first remove the pipe plugs and re-install in the center
ports. Apply PTFE tape or pipe sealant to threads of the plug before installation.

7 Model S05 Non-Metallic

sandpiperpump . com
s05nmdl2sm-rev0814

Item Part Number


1
031.166.000

031.166.002

031.166.003

031.167.000

031.167.002


031.168.000

031.168.002

031.169.000

031.194.000

031.194.002

031.195.000

031.195.003
2
050.027.354

050.027.357

050.027.360

050.022.600
3
095.091.000

095.091.001
4
114.023.551

114.023.559
5
115.140.115

115.140.308
6
132.034.360
7
135.036.506
8
165.110.551

165.110.559
9
171.062.115

171.062.308
10 171.063.115


171.063.308

11 171.064.115

171.064.308
12 171.066.115

171.066.308
13 171.075.115

171.075.308
14 196.178.520

196.178.521

196.178.542

196.178.552

196.178.557
15 286.095.354

286.095.357
15 286.095.360

286.116.000

Description................................................................... Qty
Air Valve Assembly............................................................ 1
Air Valve Assembly (with PTFE Coated Hardware) .......... 1
Air Valve Assembly (with Conductive Polypropylene) ...... 1
Air Valve Assembly (with Stroke Indicator Pins) .............. 1
Air Valve Assembly ........................................................... 1
(with Stroke Indicator Pins and PTFE Coated Hardware)
Air Valve Assembly............................................................ 1
Air Valve Assembly, Conductive Polypropylene................ 1
Air Valve Assembly (no muffler with Stroke Indicator Pins)... 1
High Temperature.............................................................. 1
High Temperature, Conductive Polypropylene.................. 1
High Temperature.............................................................. 1
High Temperature, Conductive Polypropylene.................. 1
Ball, Check, Santoprene................................................... 4
Ball, Check, Polyurethane................................................ 4
Ball, Check, Nitrile............................................................. 4
Ball, Check, PTFE............................................................ 4
Pilot Valve Assembly........................................................ 1
Conductive Ploypropylene & Conductive PVDF Options....... 1
Bracket, Intermediate....................................................... 1
Bracket, Intermediate ....................................................... 1
Bracket, Mounting............................................................ 2
Bracket, Mounting............................................................. 2
Bumper, Diaphragm......................................................... 2
Bushing, Plunger............................................................... 2
Cap, Air Inlet..................................................................... 1
Cap, Air Inlet
.......................................... 1
Capscrew, Flanged 5/16-18 X 1.00................................... 8
Capscrew, Flanged 5/16-18 X 1.00................................... 8
Capscrew, Flanged 5/16-18 X 1.25................................. 24
Inline Option Only.............................................................. 8
Capscrew, Flanged 5/16-18 X 1.25................................. 24
Inline Option Only.............................................................. 8
Capscrew, Flanged 5/16-18 X 1.50................................ 12
Capscrew, Flanged 5/16-18 X 1.50................................. 12
Capscrew, Flanged 1/4-20 X 1.25.................................... 8
Capscrew, Flanged 1/4-20 X 1.25.................................... 8
Capscrew, Flanged 5/16-18 X .88..................................... 4
Capscrew, Flanged 5/16-18 X .88..................................... 4
Chamber, Outer, PVDF..................................................... 2
Chamber, Outer, Conductive PVDF.................................. 2
Chamber, Outer, Nylon...................................................... 2
Chamber, Outer, Poly........................................................ 2
Chamber, Outer, Conductive Poly..................................... 2
Diaphragm, Santoprene ................................................... 2
Diaphragm, Polyurethane.................................................. 2
Diaphragm, Nitrile.............................................................. 2
Diaphragm, One-Piece, PTFE........................................... 2

16 286.096.600 Diaphragm, Overlay, PTFE................................................ 2


17 312.106.520 Elbow, Suction, PVDF....................................................... 2

312.106.521 Elbow, Suction, Conductive PVDF.................................... 2

312.106.542 Elbow, Suction, Nylon........................................................ 2

312.106.552 Elbow, Suction (not used with Inline option), Poly............. 2

312.106.557 Elbow, Suction, Conductive Poly....................................... 2
18 312.112.520 Elbow, Discharge, PVDF................................................... 2

312.112.521 Elbow, Discharge, Conductive PVDF................................ 2

312.112.542 Elbow, Discharge, Nylon................................................... 2

312.112.552 Elbow, Discharge (not used with Inline option), Poly......... 2

312.112.557 Elbow, Discharge, Poly...................................................... 2
19 360.099.360 Gasket, Spacer (use w/TPE Diaphragms Only)............... 2
20 360.100.379 Gasket, Air Inlet................................................................ 1
21 360.101.360 Gasket, Pilot Valve........................................................... 1
22 360.102.360 Gasket, Air Valve.............................................................. 1
23 518.138.520 Manifold, NPT, PVDF........................................................ 2

518.138.520E Manifold, BSP Tapered, PVDF.......................................... 2

518.138.521 Manifold, NPT, Conductive PVDF..................................... 2

518.138.521E Manifold, BSP Tapered, Conductive PVDF....................... 2

518.138.542 Manifold, NPT, Nylon......................................................... 2

518.138.542E Manifold, BSP Tapered, Nylon........................................... 2

518.138.552 Manifold, NPT (not used with Inline option), Poly.............. 2

518.138.552E Manifold, BSP Tapered, Poly............................................. 2

518.138.557 Manifold, NPT, Conductive Poly........................................ 2

518.138.557E Manifold, BSP Tapered, Conductive Poly.......................... 2
24 530.023.000 Muffler with metal mesh element, ..................................... 1

(Not available for Conductive Polypropylene or PVDF)

530.024.000 Muffler with porous plastic element,.................................. 1

(Not available for Conductive Polypropylene or PVDF)......

530.035.000 Muffler............................................................................... 1
25 544.005.115 Nut, Flanged 5/16-18....................................................... 36

Inline Option Only............................................................ 20

544.005.308 Nut, Flanged 5/16-18....................................................... 36

Inline Option Only............................................................ 20
26 560.001.360 O-Ring.............................................................................. 2
27 612.091.520 Plate, Outer Diaphragm,PVDF.......................................... 2

612.091.542 Plate, Outer Diaphragm, Nylon......................................... 2

612.091.552 Plate, Outer Diaphragm, Poly............................................ 2
28 612.177.330 Plate, Inner Diaphragm..................................................... 2

612.221.330 Plate, Inner Diaphragm (use with 286.116.000 )............... 2
29 620.019.115 Plunger, Actuator............................................................... 2
30 675.042.115 Ring, Retaining.................................................................. 2
31 685.056.120 Rod, Diaphragm ............................................................... 1
32 720.012.360 Seal, Diaphragm Rod........................................................ 2
33 720.045.600 Seal, Manifold (not used with Inline option)....................... 4
34 722.099.600 Seat, Check Valve, PTFE.................................................. 4

722.100.110 Seat, Check Valve, Stainless Steel................................... 4
35 518.201.552 Inline Suction Manifold (Polypropylene ONLY).................. 1
36 518.202.552 Inline Discharge Manifold (Polypropylene ONLY)............. 1
37 618.058.552 Plug, 1/2" Pipe (Inline Option Polypropylene ONLY)......... 2
42 720.065.600 Seal, Check Valve Seat (steel seats only)......................... 8

3: EXP VIEW

Composite Repair Parts List

LEGEND:
= Items contained within Air End Kits
= Items contianed within Wet End Kits
Note: Kits contain components specific to the material codes.

ATEX Compliant

sandpiperpump . com
s05nmdl2sm-rev0814

Model S05 Non-Metallic 8

MATERIAL CODES -

3: EXP VIEW

000

Assembly, sub-assembly;
and some purchased items
010 Cast Iron
015 Ductile Iron
020 Ferritic Malleable Iron
080 Carbon Steel, AISI B-1112
110 Alloy Type 316 Stainless Steel
111
Alloy Type 316 Stainless Steel
(Electro Polished)
112 Alloy C
113 Alloy Type 316 Stainless Steel
(Hand Polished)
114 303 Stainless Steel
115 302/304 Stainless Steel
117 440-C Stainless Steel (Martensitic)
120 416 Stainless Steel
(Wrought Martensitic)
148 Hardcoat Anodized Aluminum
150 6061-T6 Aluminum
152 2024-T4 Aluminum (2023-T351)
155 356-T6 Aluminum
156 356-T6 Aluminum
157 Die Cast Aluminum Alloy #380
158 Aluminum Alloy SR-319
162 Brass, Yellow, Screw Machine Stock
165 Cast Bronze, 85-5-5-5
166 Bronze, SAE 660
170 Bronze, Bearing Type,
Oil Impregnated
180 Copper Alloy
305 Carbon Steel, Black Epoxy Coated
306 Carbon Steel, Black PTFE Coated
307 Aluminum, Black Epoxy Coated
308 Stainless Steel, Black PTFE Coated
309 Aluminum, Black PTFE Coated
313 Aluminum, White Epoxy Coated
330 Zinc Plated Steel
332 Aluminum, Electroless Nickel Plated
333 Carbon Steel, Electroless
Nickel Plated
335 Galvanized Steel
337 Silver Plated Steel
351 Food Grade Santoprene
353 Geolast; Color: Black
354 Injection Molded #203-40
Santoprene Duro 40D +/-5;
Color: RED
356 Hytrel
357 Injection Molded Polyurethane
358 Urethane Rubber
(Some Applications)
(Compression Mold)
359 Urethane Rubber
360 Nitrile Rubber Color coded: RED
363 FKM (Fluorocarbon)
Color coded: YELLOW

9 Model S05 Non-Metallic

THE LAST 3 DIGITS OF PART NUMBER

364

E.P.D.M. Rubber
Color coded: BLUE
365 Neoprene Rubber
Color coded: GREEN
366 Food Grade Nitrile
368 Food Grade EPDM
371 Philthane (Tuftane)
374 Carboxylated Nitrile
375 Fluorinated Nitrile
378 High Density Polypropylene
379 Conductive Nitrile
408 Cork and Neoprene
425 Compressed Fibre
426 Blue Gard
440 Vegetable Fibre
500 Delrin 500
502 Conductive Acetal, ESD-800
503 Conductive Acetal, Glass-Filled
506 Delrin 150
520 Injection Molded PVDF
Natural color
540 Nylon
542 Nylon
544 Nylon Injection Molded
550 Polyethylene
551 Glass Filled Polypropylene
552 Unfilled Polypropylene
555 Polyvinyl Chloride
556 Black Vinyl
557 Unfilled Conductive Polypropylene
558 Conductive HDPE
559 Glass-Filled Conductive Polypropylene
570 Rulon II
580 Ryton
600 PTFE (virgin material)
Tetrafluorocarbon (TFE)
603 Blue Gylon
604 PTFE
606 PTFE
607 Envelon
608 Conductive PTFE
610 PTFE Encapsulated Silicon
611 PTFE Encapsulated FKM
632 Neoprene/Hytrel
633 FKM/PTFE
634 EPDM/PTFE
635 Neoprene/PTFE
637 PTFE, FKM/PTFE
638 PTFE, Hytrel/PTFE
639 Nitrile/TFE
643 Santoprene/EPDM
644 Santoprene/PTFE
656 Santoprene Diaphragm and
Check Balls/EPDM Seats
661 EPDM/Santoprene
666 FDA Nitrile Diaphragm,

PTFE Overlay, Balls, and Seals


668 PTFE, FDA Santoprene/PTFE
Delrin and Hytrel are registered
tradenames of E.I. DuPont.
Nylatron is a registered tradename
of Polymer Corp.
Gylon is a registered tradename
of Garlock, Inc.
Santoprene is a registered tradename
of Exxon Mobil Corp.
Rulon II is a registered tradename
of Dixion Industries Corp.
Ryton is a registered tradename
of Phillips Chemical Co.
Valox is a registered tradename
of General Electric Co.

RECYCLING

Many components of SANDPIPER


AODD pumps are made of recyclable
materials. We encourage pump users to
recycle worn out parts and pumps whenever
possible, after any hazardous pumped fluids
are thoroughly flushed.

sandpiperpump . com
s05nmdl2sm-rev0814

MAIN AIR VALVE ASSEMBLY PARTS LIST

Item
Part Number
1
031.166.000
1-A
095.106.551
1-B
031.132.000
1-C 560.101.360
1-E
165.122.551
1-F 560.026.360
1-G
675.062.115
1-H
530.031.550
1-I
165.109.551
1-J
710.011.115

Air Distribution Valve Servicing


See repair parts drawing, remove screws.
Step 1: Remove end cap retainer (1-G).
Step 2: Remove end cap (1-E).
Step 3: Remove spool part of (1-B) (caution: do not scratch).
Step 4: Press sleeve (1-B) from body (1-A).
Step 5: Inspect O-Rings (1-C) and replace if necessary.
Step 6: Lightly lubricate O-Rings (1-C) on sleeve (1-B).
Step 7: Press sleeve (1-B) into body (1-A).
Step 8: Reassemble in reverse order, starting with step 3.
Note: Sleeve and spool (1-B) set is match ground to a specified clearance
sleeve and spools (1-B) cannot be interchanged.

IMPORTANT
Read these instructions completely, before installation
and start-up. It is the responsibility of the purchaser
to retain this manual for reference. Failure to comply
with the recommendations stated in this manual will
damage the pump, and void factory warranty.

ATEX Compliant

Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
End Cap
O-Ring
End Cap Retainer
Muffler
Muffler Cap
Self-Tapping Screw

For Pumps with Virgin PTFE coated hardware:


1
031.166.002
Air Valve Assembly
1-G
675.062.308
End Cap Retainer
1-J
710.011.308
Self Tapping Screw
(Includes all other items used on 031.166.000 above)

s05nmdl2sm-rev0814

1
2
4

For Pumps w/ alternate Mesh, Sound Dampening or Piped Exhaust:


1
031.168.000
Air Valve Assembly
1
(Includes all items used on 031.166.000 above minus 1.H, 1.I and 1.J)

MAIN AIR VALVE ASSEMBLY PARTS LIST


Item
Part Number
1
031.166.003
1-A
095.106.559
1-B
031.132.000
1-C 560.101.360
1-E
165.122.551
1-F 560.026.360
1-G
675.062.115
1-H
530.031.550
1-I
165.109.559
1-J
710.011.115

Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
End Cap
O-Ring
End Cap Retainer
Muffler
Muffler Cap
Self-Tapping Screw

Qty
1
1
1
8
2
2
2
1
1
4

For Pumps with alternate Mesh Muffler or Piped Exhaust:


1
031.168.002
Air Valve Assembly

For pumps with High Temperature Options:


1
031.194.000
Air Valve Assembly
1-B
031.175.000
Sleeve and Spool Set

1
1

1
1

1
1

(Includes all items used on 031.166.003 above minus 1.H, 1.I and 1.J)

(Includes all the other items on 031.168.000 above)

031.195.000
031.175.000

Air Valve Assembly


Sleeve and Spool Set

(Includes on other items on 031.166.000 above)

sandpiperpump . com

Qty
1
1
1
8
2
2
2
1
1
4

4: AIR END

Air Distribution Valve Assembly Drawing

Model S05 Non-Metallic 10

Air Valve with Stroke Indicator Assembly Drawing,


Parts List

1-K

1-H

1-J

1-B
1-F

1-E

1-B
1-D

1-C

1-I

1-D
1-C

4: AIR END

1-F

1-A

1-E

1-G

Air Distribution Valve Servicing


See repair parts drawing, remove screws.
Step 1: Remove end cap retainer (1-G).
Step 2: Remove end cap (1-E), bumper (1-D).
Step 3: Remove spool part of (1-B) (caution, do not scratch).
Step 4: Press sleeve (1-B) from body (1-A).
Step 5: Inspect O-Rings (1-C) and replace if necessary.
Step 6: Lightly lubricate O-Rings (1-C) on sleeve (1-B).
Step 7: Press sleeve (1-B) into body (1-A).
Step 8: Reassemble in reverse order.
Note: Sleeve and spool (1-B) set is match ground to a specified clearance
sleeve and spools (1-B) cannot be interchanged.

MAIN AIR VALVE ASSEMBLY PARTS LIST


Item
Part Number
1
031.167.000
1-A
095.106.559
1-B
031.134.000
1-C 560.101.360
1-D 132.030.552
1-E
165.123.147
1-F 560.029.360
1-G
675.062.115
1-H
210.008.330
1-I
530.031.550
1-J
165.109.559
1-K
710.011.115

Description
Air Valve Assembly
Body, Air Valve
Sleeve and Spool Set
O-Ring
Bumper
End Cap
O-Ring
End Cap Retainer
Safety Clip
Muffler
Muffler Cap
Self-Tapping Screw

For Pumps with Virgin PTFE coated hardware:


1
031.167.002
Air Valve Assembly
1-G
675.062.308
End Cap Retainer
1-J
710.011.308
Self Tapping Screw

1
2
4

For Pumps with alternate Mesh Muffler or Piped Exhaust:


1
031.169.000
Air Valve Assembly

(Includes all other items used on 031.166.000 above)

(Includes all items used on 031.167.000 above minus 1.H, 1.I and 1.J)

ATEX Compliant
11 Model S05 Non-Metallic

Qty
1
1
1
8
2
2
2
2
1
1
1
4

sandpiperpump . com
s05nmdl2sm-rev0814

Pilot Valve Servicing

With Pilot Valve removed from pump.


Step 1: Remove snap ring (3-F).
Step 2: Remove sleeve (3-B), inspect O-Rings (3-C),

replace if required.

Step 3: Remove spool (3-D) from sleeve (3-B),


inspect O-Rings (3E), replace if required.

Step 4: Lightly lubricate O-Rings (3-C) and (3-E).


Reassemble in reverse order.

PILOT VALVE ASSEMBLY PARTS LIST


Item
3
3-A
3-B
3-C
3-D
3-E
3-F

Part Number
095.091.000
095.087.551
755.051.000
560.033.360
775.055.000
560.023.360
675.037.080

Description
Pilot Valve Assembly
Valve Body
Sleeve (With O-Rings)
O-Ring (Sleeve)
Spool (With O-Rings)
O-Ring (Spool)
Retaining Ring

Qty
1
1
1
6
1
3
1

4: AIR END

Pilot Valve Servicing, Assembly Drawing & Parts List

PILOT VALVE ASSEMBLY PARTS LIST


Item
3
3-A
3-B
3-C
3-D
3-E
3-F

Part Number
095.091.001
095.087.558
755.051.000
560.033.360
775.055.000
560.023.360
675.037.080

Description
Pilot Valve Assembly
Pilot Valve Body
Sleeve (With O-Rings)
O-Ring (Sleeve)
Spool (With O-Rings)
O-Ring (Spool)
Retaining Ring

Qty
1
1
1
6
1
3
1

ATEX Compliant

sandpiperpump . com
s05nmdl2sm-rev0814

Model S05 Non-Metallic 12

Intermediate Assembly Drawing


4

32
26

30

4: AIR END

29

Intermediate Assembly Drawing

Step 1: Remove plunger, actuator (29) from center of


intermediate pilot valve cavity.

Step 2: Remove Ring, Retaining (30), discard.


Step 3: Remove bushing, plunger (7), inspect for wear

and replace if necessary with genuine parts.

Step 4: Remove O-Ring (26), inspect for wear and


replace if necessary with genuine parts.

Step 5: Lightly lubricate O-Ring (26) and insert into


intermediate.

INTERMEDIATE REPAIR PARTS LIST


Item
Part Number
4
114.023.551

114.023.559
7
135.036.506
26 560.001.360
29
620.019.115
30
675.042.115
32
720.012.360

Description
Bracket, Intermediate
Bracket, Intermediate
Bushing, Plunger
O-Ring
Plunger, Actuator
Ring, Retaining*
Seal, Diaphragm Rod

Qty
1
1
2
2
2
2
2

*Note: It is recommended that when plunger components


are serviced, new retaining rings be installed.

Step 6: Reassemble in reverse order.


Step 7: Remove Seal, Diaphragm Rod (32).
Step 8: Clean seal area, lightly lubricate and install new Seal,

Diaphragm Rod (32).

13 Model S05 Non-Metallic

IMPORTANT
When the pumped product source is at a higher
level than the pump (flooded suction condition),
pipe the exhaust higher than the product source
to prevent siphoning spills. In the event of a
diaphragm failure a complete rebuild of the
center section is recommended.

sandpiperpump . com
s05nmdl2sm-rev0814

Diaphragm Service Drawing


19
13

15
27

31
6

11

28

14
19

Use With TPE


Diaphragms Only

25

27

15

13

Diaphragm Orientation
14

Torque:
120 in/lbs

Install diaphragm and spacer


as shown above.

11

Diaphragm Service Drawing - with Overlay


13

16

15

27

31
6

14

11

15
16

25

27

Torque:
120 in/lbs

13

Diaphragm Orientation
14

Install diaphragm and spacer


as shown above.

11

5: WET END

28

Diaphragm Service Drawing - with One-Piece Bonded


13

15
11

31
6

14

28
25

15

13
14
11

sandpiperpump . com
s05nmdl2sm-rev0814

Diaphragm Orientation
Install diaphragm as shown above.

Model S05 Non-Metallic 14

DIAPHRAGM SERVICING
Step 1: With manifolds and outer chambers
removed, remove diaphragm assemblies from
diaphragm rod. DO NOT use a pipe wrench or similar
tool to remove assembly from rod. Flaws in the rod
surface may damage bearings and seal. Soft jaws
in a vise are recommended to prevent diaphragm
rod damage.
Step 1.A: NOTE: Not all inner diaphragm plates
are threaded. Some models utilize a though hole in
the inner diaphragm plate. If required to separate
diaphragm assembly, place assembly in a vice,
gripping on the exterior cast diameter of the inner
plate. Turn the outer plate clockwise to separate the
assembly.
Always inspect diaphragms for wear cracks or
chemical attack. Inspect inner and outer plates for
deformities, rust scale and wear. Inspect intermediate
bearings for elongation and wear. Inspect diaphragm
rod for wear or marks.
Clean or repair if appropriate. Replace as required.
Step 2: Reassembly: There are two different types
of diaphragm plate assemblies utilized throughout the
Sandpiper product line: Outer plate with a threaded
stud, diaphragm, and a threaded inner plate.

5: WET END

Outer plate with a threaded stud, diaphragm, and


an inner plate with through hole. Secure threaded
inner plate in a vice. Ensure that the plates are being
installed with the outer radius against the diaphragm.

Step 8: On opposite side of pump thread the


remaining assembly onto the diaphragm rod. Using a
torque wrench tighten the assembly to the diaphragm
rod. Align diaphragm through bolt holes always going
forward past the recommended torque. Torque values
are called out on the exploded view. NEVER reverse
to align holes, if alignment cannot be achieved
without damage to diaphragm, loosen complete
assemblies rotate diaphragm and reassemble as
described above.
Step 9: Complete assembly of entire unit.
One Piece Diaphragm Servicing (Bonded PTFE
with integral plate) The One Piece diaphragm has
a threaded stud installed in the integral plate at the
factory. The inner diaphragm plate has a through
hole instead of a threaded hole. Place the inner
plate over the diaphragm stud and thread the first
diaphragm / inner plate onto the diaphragm rod only
until the inner plate contacts the rod. Do not tighten. A
small amount of grease may be applied between the
inner plate and the diaphragm to facilitate assembly.
Insert the diaphragm / rod assembly into the pump
and install the outer chamber. Turn the pump over
and thread the second diaphragm / inner plate onto
the diaphragm rod. Turn the diaphragm until the
inner plate contacts the rod and hand tighten the
assembly. Continue tightening until the bolt holes
align with the inner chamber holes. DO NOT LEAVE
THE ASSEMBLY LOOSE.

Step 3: Lightly lubricate, with a compatible material,


the inner faces of both outer and inner diaphragm plates
when using on non Overlay diaphragms (For EPDM
water is recommended). No lubrication is required.
Step 4: Push the threaded outer diaphragm
plate through the center hole of the diaphragm.
Note: Most diaphragms are installed with the
natural bulge out towards the fluid side. S05,
S07, and S10 nonmetallic units are installed
with the natural bulge in towards the air side.
Step 5: Thread or place, outer plate stud into
the inner plate. For threaded inner plates use a
torque wrench to tighten the assembly together.
Torque values are called out on the exploded view.
Repeat procedure for second side assembly. Allow a
minimum of 15 minutes to elapse after torquing then
re-torque the assembly to compensate for stress
relaxation in the clamped assembly.
Step 6: Thread one assembly onto the diaphragm
rod with sealing washer (when used) and bumper.
Step 7: Install diaphragm rod assembly
into pump and secure by installing the outer
chamber in place and tightening the capscrews.

15 Model S05 Non-Metallic

IMPORTANT
Read these instructions completely,
before installation and start-up.
It is the responsibility of the
purchaser to retain this manual for
reference. Failure to comply with
the recommendations stated in this
manual will damage the pump, and
void factory warranty.

sandpiperpump . com
s05nmdl2sm-rev0814

Solenoid Shifted Air Valve Drawing

41
8
20

Wiring
Diagram

40

3rd Terminal
for ground.

#2 Terminal
Neutral
(Negative)

30
39

42

26

#1 Terminal
Power
(Positive)

26
42
30
12

4
22
38

SOLENOID SHIFTED AIR VALVE PARTS LIST

(Includes all items used on Composite Repair Parts List except as shown)

Item
Part Number
4
114.023.551
38
893.099.000
39
219.001.000

219.004.000

219.002.000

219.003.000
40
241.001.000

241.003.000

41
171.065.115
42
618.050.150

SOLENOID SHIFTED OPERATION

The Solenoid Shifted pump has a solenoid operated, air distribution valve in
place of the standard pilot operated, air distribution valve. Where a pilot valve
is normally utilized to cycle the pumps air distribution valve, an electric solenoid
is utilized. The solenoid coil is connected to a customer-supplied control. As the
solenoid is powered, one of the pumps air chambers is pressurized while the
other chamber is exhausted. When electric power is turned off, the solenoid
shifts and the pressurized chamber is exhausted while the other chamber
is pressurized. By alternately applying and removing power to the solenoid,
the pump cycles much like a standard pump, with one exception. This option
provides a way to precisely control and monitor pump speed.

s05nmdl2sm-rev0814

For Explosion Proof Solenoid Coils used in North America and


outside the European Union.
219.009.001
Solenoid Coil, 120VAC 60 Hz 1
219.009.002
Solenoid Coil, 240VAC 60 Hz 1
219.009.003
Solenoid Coil, 12VDC
1
219.009.004
Solenoid Coil, 24VDC
1
219.009.005
Solenoid Coil, 110VAC 50 Hz
1
219.009.006
Solenoid Coil, 230VAC 50 Hz
1
Item 40 (Conduit Connector) is not required
2G EEx
EExmmccT5
II T5
IIII 2G
3/2c2G
EEx
m c II T5
IIII 2D
IP65
T100C

*Special Conditions For Safe Use

sandpiperpump . com

4
2

6: OPTIONAL


39





BEFORE WIRING THE SOLENOID, make certain it is compatible with your


system voltage.

A fuse corresponding to its rated current (max. 3*I according IEC 60127.2.1) or a
motor protecting switch with short-circuit and thermal instantaneous tripping (set to
rated current) shall be connected in series to each solenoid as short circuit protection.
For very low rated currents of the solenoid the fuse of lowest current value according
to the indicated IEC standard will be sufficient. The fuse may be accommodated in the
associated supply unit or shall be separately arranged. The rated voltage to the fuse
shall be equal to or greater than the stated rated voltage of the magnet coil. The
breakage capacity of the fuse-link shall be as high as or higher than the maximum
expected short circuit current at the location of the installation (usually 1500 A). A
maximum permissible ripple of 20% is valid for all magnets of direct-current design.

Qty
1
1
1
1
1
1
1
1

IEC EEX m T4

BEFORE INSTALLATION

rat

Description
Bracket, Intermediate
Solenoid Valve, NEMA4
Solenoid Coil, 24VDC
Solenoid Coil, 24VAC/12VDC
Solenoid Coil, 120VAC
Solenoid Coil, 240VAC
Connector, conduit
Conduit Connector with
Suppression Diode (DC Only)
Capscrew, Flanged 1/4.20 x 1.00
Plug (Replaces Item 7)

II 2D c IP65 T100C
For ATEX Compliant Solenoid Coils used in the European Union
1
39 219.011.001 Solenoid Coil, Single mounting 12 VDC, 3.3W / 267mA
219.011.002 Solenoid Coil, Single mounting 24 VDC, 3.3W / 136mA
1

219.011.003 Solenoid Coil, Single mounting 110/120 VAC, 3.4W / 29mA 1

219.011.004 Solenoid Coil, Single mounting 220/240 VAC, 3.4W / 15mA 1

Note: Item 40 (Conduit Connector) is not required

Compressed Air Temperature Range: Maximum Ambient


Temperature to plus 50C
Model S05 Non-Metallic 16

Dual Port Option Drawing

1" NPT or 1" BSP Tapered External


" NPT or " BSP Tapered Internal
Connection

" NPT or " BSP Tapered


Connection

37
38

" NPT or " BSP Tapered


Connection

Illustration for Dual Port Suction and Single or Dual Port Discharge
*Dual suction/dual discharge = no manifold.

6: OPTIONAL

DUAL PORT SUCTION AND/OR DUAL PORT DISCHARGE


REPAIR PARTS LIST

Item
10*

11*

17




18




25*

37

38

Part Number
Description
171.063.115
Capscrew, Flanged 5/16-18 x 1.25
171.063.308
Capscrew, Flanged 5/16-18 x 1.25
171.064.115
Capscrew, Flanged HD 5/16-18 X 1.50
171.064.308
Capscrew, Flanged HD 5/16-18 X 1.50
312.106.520N
Elbow, " NPT (replaces 312.106.520)
312.106.521N
Elbow, " NPT (replaces 312.106.521)
312.106.542N
Elbow, " NPT (replaces 312.106.542)
312.106.552N
Elbow, " NPT (replaces 312.106.552)
312.106.557N
Elbow, " NPT (replaces 312.106.557)
312.112.520N
Elbow, " NPT (replaces 312.112.520)
312.112.521N
Elbow, " NPT (replaces 312.112.521)
312.112.542N
Elbow, " NPT (replaces 312.112.542)
312.112.552N
Elbow, " NPT (replaces 312.112.552)
312.112.557N
Elbow, " NPT (replaces 312.112.557)
544.005.115
Nut, Flanged 5/16-18
544.005.308
Nut, Flanged 5/16-18
115.144.305
Bracket, Free Standing (replaces 115.140.115)
115.144.306
Bracket, Free Standing (replaces 115.140.115)
171.068.115
Capscrew, Flanged 5/16-18 X 1.63
171.068.308
Capscrew, Flanged 5/16-18 X 1.63
*Hardware quantities are variable based on porting configurations

17 Model S05 Non-Metallic

Qty
8
8
4
4
2
2
2
2
2
2
2
2
2
2
20
20
2
2
8
8

ATEX Compliant
IMPORTANT
Read these instructions completely, before
installation and start-up. It is the responsibility
of the purchaser to retain this manual
for reference. Failure to comply with the
recommendations stated in this manual will
damage the pump, and void factory warranty.

sandpiperpump . com
s05nmdl2sm-rev0814

Written Warranty

5 - YEAR Limited Product Warranty


Quality System ISO 9001 Certified Environmental Management Systems ISO 14001 Certified
Warren Rupp, Inc. (Warren Rupp) warrants to the original end-use purchaser that no product sold by
Warren Rupp that bears a Warren Rupp brand shall fail under normal use and service due to a defect in material
or workmanship within five years from the date of shipment from Warren Rupps factory. Warren Rupp brands
include SANDPIPER, MARATHON, PortaPump, SludgeMaster and Tranquilizer.
~ See complete warranty at sandpiperpump.com/content/warranty-certifications ~

Declaration of Conformity

Signature of authorized person

October 20, 2005


Date of issue

David Roseberry
Printed name of authorized person

Engineering Manager
Title

Revision Level: F

August 23, 2012


Date of revision

7: WARRANTY

Manufacturer: Warren Rupp, Inc., 800 N. Main Street


Mansfield, Ohio, 44902 USA
Certifies that Air-Operated Double Diaphragm Pump Series: HDB, HDF, M Non-Metallic,
S Non-Metallic, M Metallic, S Metallic, T Series, G Series, U Series, EH and SH High Pressure,
RS Series, W Series, SMA and SPA Submersibles, and Tranquilizer Surge Suppressors comply with
the European Community Directive 2006/42/EC on Machinery, according to Annex VIII.
This product has used Harmonized Standard EN809:1998+A1:2009, Pumps and Pump Units
for Liquids - Common Safety Requirements, to verify conformance.

EC Declaration of Conformity
In accordance with ATEX Directive 94/9/EC,
Equipment intended for use in potentially explosive environments.
Manufacturer: Warren Rupp, Inc., A Unit of IDEX Corportion
800 North Main Street, P.O. Box 1568, Mansfield, OH 44902 USA
EN 60079-25: 2011
For pumps equipped with Pulse Output ATEX Option
Quality B.V. (0344)

Applicable Standard:
EN13463-1: 2009
EN13463-5: 2011

AODD Pumps and Surge Suppressors


For Type Examination Designations
AODD (Air-Operated Double Diaphragm) Pumps
EC Type Examination Certificate No. Pumps: KEMA 09ATEX0071 X
DEKRA Certification B.V. (0344)
Meander 1051
6825 MJ Arnhem
The Netherlands

DATE/APPROVAL/TITLE:
14 MAY 2014

EC Declaration of Conformity

David Roseberry, Engineering Manager

David Roseberry, Engineering Manager

DATE/APPROVAL/TITLE:
27 MAY 2010

ATEX Summary of Markings

Type

Marking

Listed In

AODD (Air-Operated Double Diaphragm) Pumps


EC Type Examination Certificate No. Pumps: KEMA 09ATEX0071 X
KEMA Quality B.V.
Utrechtseweg 310
6812 AR Arnhem, The Netherlands

Pump types, S1F, S15, S20,


and S30 provided with the
pulse output option

KEMA 09ATEX0071 X KEMA 09ATEX0071 X


II 2 G Ex ia c IIC T5
CE 0344
II 3/2 G Ex ia c IIC T5
KEMA 09ATEX0071 X
II 2 D Ex c iaD 20 IP67 T100oC
KEMA 09ATEX0071 X

No
Yes
Yes

Pump types, S1F, S15, S20,


and S30 provided with the
integral solenoid option

II 2 G EEx m c II T5
II 3/2 G EEx m c II T5
II 2 D c IP65 T100oC

KEMA 09ATEX0071 X KEMA 09ATEX0071 X


CE 0344
KEMA 09ATEX0071 X
KEMA 09ATEX0071 X

No
Yes
Yes

Pump types, HDB1, HDB40,


HDB2, HDB50, HDB3, HDF1,
HDF25, HDF2, HDF3M, PB,
S05, S1F, S15, S20, S30, SB1,
SB25, ST1, ST40, G15, G20,
and G30, without the above
listed options, no aluminum
parts

II 1 G c T5
II 3/1 G c T5
II 1 D c T100oC
I M1 c
I M2 c

KEMA 09ATEX0071 X KEMA 09ATEX0071 X


KEMA 09ATEX0072 X KEMA 09ATEX0071 X
CE 0344
KEMA 09ATEX0071 X
KEMA 09ATEX0071 X
KEMA 09ATEX0072 X

No
Yes
Yes
No
Yes

Pump types, DMF2, DMF3,


HDB1, HDB40, HDB2,
HDB50, HDB3, HDF1, HDF25,
HDF2, HDF3M, PB, S05, S1F,
S15, S20, S30, SB1, SB25,
SE, ST1, ST25, ST1, ST40,
U1F, G05, G1F, G15, G20, and
G30

II 2 G c T5
II 3/2 G c T5
II 2 D c T100oC

KEMA 09ATEX0072 X KEMA 09ATEX0072 X


CE
KEMA 09ATEX0072 X
KEMA 09ATEX0072 X

No
Yes
Yes

Surge Suppressors all types

II 2 G T5
II 3/2 G T5
II 2 D T100oC

AODD Pumps and Surge Suppressors


For Type Examination Designations, see page 2 (back)
EN 60079-25: 2004
For pumps equipped with Pulse Output ATEX Option
KEMA Quality B.V. (0344)

Applicable Standard:
EN13463-1: 2001,
EN13463-5: 2003

Manufacturer: Warren Rupp, Inc., A Unit of IDEX Corportion


800 North Main Street, P.O. Box 1568, Mansfield, OH 44901-1568 USA

In accordance with ATEX Directive 94/9/EC,


Equipment intended for use in potentially explosive environments.

EC Declaration of Conformity

7: WARRANTY

Non-Conductive
Fluids

EC Type Certificate No. Pumps: KEMA 09ATEX0071 X


Type Certificate No. Pumps: KEMA 09ATEX0072 X
Type Certificate No. Suppressors: KEMA 09ATEX0073

KEMA 09ATEX0073
CE

KEMA 09ATEX0073
KEMA 09ATEX0073
KEMA 09ATEX0073

No
Yes
Yes

You might also like