System Sensor DST1 Data Sheet
System Sensor DST1 Data Sheet
Accessories
Conventional and
Intelligent Detectors
Multi-Voltage Relays
Special Applications
Watertight Detectors
Reshaping Duct
Smoke Detection
The InnovairFlex product line offers testing and inspection
features to meet any code. The 2:1 sensor-to-power capability
allows a power board to monitor both supply and return side
detectors when required. The easily accessible Test/Reset button
simplifies testing for conventional 4-wire models. Plus, the flexible
housing overcomes mounting constraints by adjusting to fit a broad
range of applications.
System Sensor provides increased flexibility with a variety of
accessories, including two remote test stations and several different
means of visible and audible system annunciation. As with our duct
smoke detectors, all accessories are UL listed.
Unmatched Flexibility
D4120
Duct Smoke Detector in Rectangular Orientation
Superior Features
Integrated low-flow technology
One easy-access Test/Reset button
(for conventional 4-wire models)
Patented interconnectability for multi-fan shutdown
Built-in short circuit protection from wiring errors
Field-selectable settings for configuring the detectors
Sampling tubes install from both front and back of the
detector with patented snap in place feature.
Easy and quick mounting to round or rectangular ducts
of 1 ft. or 12 ft. (0.3 m to 3.7 m) wide
systemsensor.com/flex
Conventional
Duct Smoke Detectors
InnovairFlex duct smoke detectors combine an impressive
collection of innovations to greatly simplify HVAC system monitoring.
One unit can accommodate multiple installation footprints to
overcome mounting constraints. Tool-free, plug-in sampling tubes
speed and simplify installation. Broad temperature and humidity
ranges accommodate exposure to environmental extremes. Easily
visible status indications, a readily accessible test feature, and remote
test station accessories simplify testing and maintenance. With its
unmatched flexibility, InnovairFlex can adjust to fit any application.
2D51
D4120
D4240
D4S
D4P120
D4120W
D2
Intelligent
Duct Smoke Detectors
InnovairFlex duct smoke detectors combine an impressive
collection of innovations designed to save you time and money and
provide the flexibility you need in the field. An adjustable housing
overcomes mounting constraints. Plug-in, tool-free sampling tubes
speed installation. The DNR model accommodates a wide variety
of intelligent smoke detectors (detector head sold separately).
With these features and many more, InnovairFlex is reshaping duct
smoke detection.
DNRECL
DNRHS
DNRW
systemsensor.com/flex
2251BR
Watertight
Duct Smoke Detectors
Is your HVAC installation on the rooftop? NEMA 4-rated InnovairFlex
watertight duct smoke detectors operate in the most challenging
conditions without costly and bulky enclosures. Watertight
InnovairFlex duct smoke detectors (D4120W conventional, DNRW
intelligent) include a UV-resistant housing that provides protection
against dirt, rain, and other water sources, so you can mount these
detectors on HVAC equipment in harsh environments while saving on
materials and labor.
2:1 Sensor-to-Power
Board Configuration
D4120
D4S
D4120W
DNRW
Sampling Tube
The InnovairFlex sampling tube
may be installed from the front
or back of the detector. The tube
locks securely into place and
can be removed by releasing
the front or rear locking tab
(rear locking tab shown below).
Accessories
Conventional and Intelligent
Duct smoke detector accessories add functionality to the duct smoke
detection system by allowing quick, convenient inspections at eye
level and effective audible and visible notification options. All System
Sensor duct smoke detectors and accessories are UL listed.
RTS151
Accessories
APA151*
DH400OE-1*
DST1*
DST1.5 *
DST3*
DST5*
DST10*
ETX*
P48-21-00*
RA100Z*
RTS151*
RTS151KEY*
RTS2
RTS2 - AOS
SENS-RDR
RTS2-AOS
Special Applications
Pendant Mount
The System Sensor 2151 low-profile photoelectric smoke detector with a
B114LP or B114LPBT base is listed to Underwriters Laboratories 268A
specifically for use in no-flow/low-flow air-handling systems.
Special Applications
2151
2D151
B114LP
B114LPBT
B210LP
D4P120
Note: 2151 with B114LP or B114LPBT is not remote test capable, for remote testing use 2D51, B210LP with D4P120.
systemsensor.com/flex
www.systemsensor.com/flex
2014 System Sensor. Product specifications subject to change without notice.