0% found this document useful (0 votes)
295 views8 pages

System Sensor DST1 Data Sheet

Buy the System Sensor DST1 at JMAC Supply. https://www.jmac.com/System_Sensor_DST1_p/system-sensor-dst1.htm?=scribd

Uploaded by

JMAC Supply
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
295 views8 pages

System Sensor DST1 Data Sheet

Buy the System Sensor DST1 at JMAC Supply. https://www.jmac.com/System_Sensor_DST1_p/system-sensor-dst1.htm?=scribd

Uploaded by

JMAC Supply
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

HVAC Duct Smoke

Detection and Monitoring


PRODUCTS

Accessories
Conventional and
Intelligent Detectors
Multi-Voltage Relays
Special Applications
Watertight Detectors

Reshaping Duct
Smoke Detection
The InnovairFlex product line offers testing and inspection
features to meet any code. The 2:1 sensor-to-power capability
allows a power board to monitor both supply and return side
detectors when required. The easily accessible Test/Reset button
simplifies testing for conventional 4-wire models. Plus, the flexible
housing overcomes mounting constraints by adjusting to fit a broad
range of applications.
System Sensor provides increased flexibility with a variety of
accessories, including two remote test stations and several different
means of visible and audible system annunciation. As with our duct
smoke detectors, all accessories are UL listed.

Unmatched Flexibility

D4120
Duct Smoke Detector in Rectangular Orientation

Versatile Mounting Options


Square or Rectangular Footprint

Air velocity rating from 100 ft/min to 4,000 ft/min


(0.5 m/s to 20.32 m/sec)
Versatile mounting options in square or rectangular
configuration with modular construction
Broader ranges for operating temperature (4F to 158F)
and humidity (0% to 95% non-condensing)

Superior Features
Integrated low-flow technology
One easy-access Test/Reset button
(for conventional 4-wire models)
Patented interconnectability for multi-fan shutdown
Built-in short circuit protection from wiring errors
Field-selectable settings for configuring the detectors
Sampling tubes install from both front and back of the
detector with patented snap in place feature.
Easy and quick mounting to round or rectangular ducts
of 1 ft. or 12 ft. (0.3 m to 3.7 m) wide

systemsensor.com/flex

Conventional
Duct Smoke Detectors
InnovairFlex duct smoke detectors combine an impressive
collection of innovations to greatly simplify HVAC system monitoring.
One unit can accommodate multiple installation footprints to
overcome mounting constraints. Tool-free, plug-in sampling tubes
speed and simplify installation. Broad temperature and humidity
ranges accommodate exposure to environmental extremes. Easily
visible status indications, a readily accessible test feature, and remote
test station accessories simplify testing and maintenance. With its
unmatched flexibility, InnovairFlex can adjust to fit any application.

Conventional Duct Smoke Detection Devices

2D51

4-wire Photoelectric Sensor Head


Photoelectronic Low-Profile Plug-In Detector for
Special Applications. For replacement purposes with
4-wire InnovairFlex duct smoke detectors.
Note: The 2D51 needs to be used with the D4P120
and B210LP for pendant mount applications.

D4120

4-wire photoelectric low-flow duct smoke detector, 24 VAC/DC, 120 VAC

D4240

4-wire photoelectric low-flow duct smoke detector, 24 VAC/DC, 240 VAC

D4S

4-wire photoelectric sensor component only

D4P120

4-wire photoelectric power board component only, 24 VAC/DC, 120 VAC

D4120W

Watertight 4-wire photoelectric duct smoke detector

D2

2-wire photoelectric low-flow duct smoke detector

4-Wire Photoelectric, integrated low-flow technology


Air velocity rating from 100 ft/min to 4,000 ft/min
(0.5 m/s to 20.32 m/sec)
Versatile mounting options: square or rectangular configuration
Plug-in sensor and latest sensor technology help prevent
false alarms
Broad ranges for operating temperature (4F to 158F) and humidity
(0% to 95% non-condensing)
Patented sampling tube installs from front or back of the detector
with no tools required
Increased wiring space with an additional -inch conduit knockout
One easy-access Test/Reset button and improved LED status
Patented interconnect feature for multi-fan shutdown
New high-contrast terminal designations
Built-in short circuit protection from operator wiring errors
Field-selectable settings for configuring the detector
Two DPDT Form-C relay contacts
24 VAC/DC or 120 VAC
Backward compatibility with existing Innovair products,
including remote accessories

Intelligent
Duct Smoke Detectors
InnovairFlex duct smoke detectors combine an impressive
collection of innovations designed to save you time and money and
provide the flexibility you need in the field. An adjustable housing
overcomes mounting constraints. Plug-in, tool-free sampling tubes
speed installation. The DNR model accommodates a wide variety
of intelligent smoke detectors (detector head sold separately).
With these features and many more, InnovairFlex is reshaping duct
smoke detection.

Intelligent Duct Smoke Detection Devices


DNR

Intelligent non-relay photoelectric duct smoke detector.


*Detector head sold separately

DNRECL

Eclipse series intelligent duct smoke detector housing

DNRHS

High sensitivity duct smoke detector which provides very


early warning fire protection in interior duct applications

DNRW

Watertight intelligent non-relay photoelectric low-flow duct smoke detector


*Detector head sold separately

Photoelectric, integrated low-flow technology


(detector head sold separately)
Air velocity rating from 100 ft/min to 4,000 ft/min (DNR)
Air velocity rating from 300 ft/min to 4000ft/min
(1.52m/s to 20.32m/sec) (DNRECL & DNRHS)
Adjusts to square and rectangular mounting configurations
Broad ranges for operating temperature (4F to 158F)
and humidity (0% to 95% non-condensing)
Patented tool-free, plug-in sampling tubes
New cover tamper signal
Increased wiring space with a new 34-inch conduit knockout
Housing has space for mounting a relay module
Easily accessible code wheels on sensor head (sold separately)
Clear cover for convenient visual inspection
UL 268A listed
Remote testing capability
Requires com line power only
NEMA Type 4 UL listed for non-hazardous indoor and outdoor
applications (DNRW only)
UV-resistant, UL-listed housing and cover material (DNRW only)
24 VDC operation (DNRHS)
Temperature range 32F to 100F (0C to 38C) (DNRHS)

systemsensor.com/flex

2251BR

Photoelectric Smoke Detector


For use with DNR(W) duct smoke detectors, the
intelligent plug-in smoke detector with integral
communication provides point location for alarm
communication and selective maintenance.

Watertight
Duct Smoke Detectors
Is your HVAC installation on the rooftop? NEMA 4-rated InnovairFlex
watertight duct smoke detectors operate in the most challenging
conditions without costly and bulky enclosures. Watertight
InnovairFlex duct smoke detectors (D4120W conventional, DNRW
intelligent) include a UV-resistant housing that provides protection
against dirt, rain, and other water sources, so you can mount these
detectors on HVAC equipment in harsh environments while saving on
materials and labor.

Watertight Duct Smoke Detectors

2:1 Sensor-to-Power
Board Configuration
D4120

D4S

InnovairFlex 4-wire duct smoke detector has the ability


to power two sensors from one power board. With its
2:1 sensor-to-power board capability, the power board
of the D4120 may be used to monitor a second D4S
sensor simultaneously. This is perfect for applications
where monitoring both supply and return are required.

D4120W

Watertight 4-wire photoelectric duct smoke detector

DNRW

Watertight intelligent non-relay photoelectric low-flow duct smoke detector


*Detector head sold separately

NEMA Type 4 UL listed for non-hazardous indoor


and outdoor applications
UV Resistant, UL listed housing and cover material
4-Wire Photoelectric, integrated low-flow technology
Air velocity rating from 100 ft/min to 4,000 ft/min
(0.5 m/s to 20.32 m/sec)
Versatile mounting options: square or rectangular configuration
Plug-in sensor offers the latest sensor technology helps to
prevent false alarms
Broad ranges for operating temperature (4F to 158F)
and humidity (0% to 95% non-condensing)
Patented sampling tube installs from front or back of the
detector with no tools required
Increased wiring space with additional -inch conduit knockout
One easy-access Test/Reset button and improved LED status
Patented interconnect feature for multi-fan shutdown
New high contrast terminal designations
Built-in short circuit protection from operator wiring errors
Field-selectable settings for configuring the detector
Two DPDT Form-C relay contacts
24 VAC/DC or 120VAC
Backward compatibility with existing Innovair products,
including remote accessories

Sampling Tube
The InnovairFlex sampling tube
may be installed from the front
or back of the detector. The tube
locks securely into place and
can be removed by releasing
the front or rear locking tab
(rear locking tab shown below).

Accessories
Conventional and Intelligent
Duct smoke detector accessories add functionality to the duct smoke
detection system by allowing quick, convenient inspections at eye
level and effective audible and visible notification options. All System
Sensor duct smoke detectors and accessories are UL listed.

RTS151

Accessories
APA151*

Remote annunciator with piezo alarm

DH400OE-1*

Weatherproof duct smoke detector enclosure

DST1*

Metal sampling tube duct width up to 1ft (0.3m)

DST1.5 *

Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m)

DST3*

Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m)

DST5*

Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m)

DST10*

Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m)

ETX*

Metal exhaust tube duct width 1ft (0.3m)

P48-21-00*

End cap for metal sampling tubes

RA100Z*

Remote annunciator alarm LED

RTS151*

Remote test station

RTS151KEY*

Remote test station with key lock

RTS2

Multi-signaling accessory, without strobe

RTS2 - AOS

Multi-signaling accessory with add-on strobe

SENS-RDR

Utilizes infrared technology to read the sensitivity


of i3 series detectors

*For use with Coventional and Intelligent Duct Smoke Detectors

RTS2-AOS

Special Applications
Pendant Mount
The System Sensor 2151 low-profile photoelectric smoke detector with a
B114LP or B114LPBT base is listed to Underwriters Laboratories 268A
specifically for use in no-flow/low-flow air-handling systems.

Special Applications
2151

Low-profile photoelectric plug-in detector

2D151

Low-profile photoelectric plug-in detector

B114LP

120 VAC detector base

B114LPBT

24VAC/DC detector base

B210LP

Intelligent base - 15-32 VDC

D4P120

4-wire photoelectric power board component only, 24 VAC/DC, 120 VAC

Note: 2151 with B114LP or B114LPBT is not remote test capable, for remote testing use 2D51, B210LP with D4P120.

systemsensor.com/flex

Founded in 1984, System Sensor is a global


manufacturer of fire and life safety devices,
specializing in smoke detection, carbon
monoxide detection, and notification technology.
System Sensor develops products for real-world
applications worldwide. With sales, service,
and manufacturing facilities throughout the
Americas, Europe, and Asia, System Sensor
places a premium on research and development
to provide the most reliable, innovative, and
comprehensive line of products in the industry.

www.systemsensor.com/flex
2014 System Sensor. Product specifications subject to change without notice.
HVBR63001 12/14

You might also like