M0139ACD
M0139ACD
M0139ACD
MRx18/x18 &
MRx18/x18/x18 &
MRx18/y18/y18 &
MRx18/y18
Dual- / Triple-Segment
and
Dual-Band
User's Manual
M0139ACD
Page 2
M0139ACD.doc
TABLE OF CONTENTS
1. GENERAL
1.1.
USED ABBREVIATIONS
1.2.
1.3.
1.4.
10
2. INTRODUCTION
13
2.1.
PURPOSE
13
2.2.
13
3. FUNCTIONAL DESCRIPTION
15
3.1.
GENERAL
15
3.2.
17
19
4.1.
MECHANICAL INSTALLATION
19
4.2.
ELECTRICAL INSTALLATION
20
5. SOFTWARE SETUP
23
5.1.
LOGIN
23
5.2.
25
5.3.
STATUS BAR
25
5.4.
STATUS
26
5.5.
5.5.1.
5.5.2.
5.5.3.
5.5.4.
5.5.5.
SETTINGS
Settings - Radio Frequency
Settings - Alarms
Settings - Modem Control
Settings - LAN Connectivity
Settings - User Account
29
29
34
35
37
40
Page 3
5.6.
MAINTENANCE
41
5.7.
LOGOUT
43
5.8.
44
6. OPTIONAL EQUIPMENT
45
6.1.
45
6.2.
ANTENNA
45
6.3.
ADAPTER CABLE
45
47
7.1.
ALARM LEDS
47
7.2.
48
8. APPENDIX
51
8.1.
8.1.1.
8.1.2.
51
51
52
8.2.
53
8.3.
53
8.4.
54
9. INDEX
57
59
Page 4
M0139ACD.doc
Page 5
Page 6
M0139ACD.doc
1 General
1. GENERAL
1.1. USED ABBREVIATIONS
3GPP
ALC
AMPS
BCCH
BITE
BTS
CDMA
CEPT
CF
CFO
DL
EDGE
ESD
ETACS
ETS
ETSI
FSK
GSM
GUI
I2C-Bus
ID No
IF
LED
LMT
LNA
MCC
MNC
MOR
MR
MS
MTBF
OIP-3
OMC
PA
PCMCIA
PCS
PSTN
PSU
Rev
RF
RLP
RSSI
RTC
RX
Serial Clock
Serial Data
Short Message Service Center
Total Access Communication System
Traffic Channel
Time Division Multiple Access
Transmitter
User Equipment
Uplink
Universal Mobile Telecommunication System
Uninterruptable Power Supply
Uniform Resource Locutor
Voltage Standing Wave Ratio
Wide Code Division Multiple Access
Wireless Innovations Group
M0139ACD.doc
1 General
Page 9
Page 10
M0139ACD.doc
1 General
United States
Andrew Solutions,
Andrew LLC, A CommScope Company
Phone
+1-905-878-3457 (Office)
+1 416-721-5058 (Mobile)
Phone
+1-888-297-6433
Fax
+1-905-878-3297
Fax
+1-919-329-8950
[email protected]
[email protected]
Andrew Solutions,
A CommScope Company
Phone
+ 55-15-9104-7722
Phone
+ 52-55-1346-1900 (Office)
+52-1-55-5419-5260 (Mobile ).
Fax
+ 55-15-2102-4001
Fax
+52-55-1346-1901
APAC Countries:
China
Andrew Solutions Hong Kong
Australia
Andrew Corporation (Australia)
LLC Pty Ltd.
Room 915
Chevalier Commercial Centre
8 Wang Hoi Rd
Kowloon Bay SAR
Hong Kong
Unit 1
153 Barry Road
Campbellfield
VIC 3061
Australia
Phone
+852-310-661-00
Phone
+613-9300-7969
Fax
+852-2751-7800
Fax
+613-9357-9110
Page 11
France
Phone
+44-1189-366-792
Phone
+33 1 30 05 45 50
Fax
+44-1189-366-773
Fax
+33 1 34 61 13 74
Germany
Czech Republic
Industriering 10
86675 Buchdorf
Germany
U Moru 888
53006 Pardubice
Czech Republic
Phone
+49-9099-69-0
Phone
+420-464-6280-80
Fax
+49-9099-69-930
Fax
+420-464-6280-94
Austria
Switzerland
Weglgasse 10
Wien-Schwechat 2320
Austria
Tiergartenweg 1
CH-4710 Balsthal
Switzerland
Phone
+43-1706-39-99-10
Phone
+41-62-386-1260
Fax
+43-1706-39-99-9
Fax
+41-62-386-1261
Italy
Via de Crescenzi 40
Faenza 48018
Italy
C/ Salvatierra, 5 - 3a pt.
28034 Madrid
Spain
Phone
+39-0546-697111
Phone
+34-91-745-20 40
Fax
+39-0546-682768
Fax
+34-91-564-29 85
Page 12
M0139ACD.doc
2 Introduction
2. INTRODUCTION
2.1. PURPOSE
The MRx18 miniRepeater a bi-directional amplifier used to enhance signals between a
mobile and a base station in a mobile network. It has been designed to increase signal
strength in small and medium sized areas such as offices, shops, and basements. By
boosting the signal level the MRx18 increases indoor coverage and allows high data
rate connectivity.
If weak signal transmissions occur within the coverage area due to indoor applications,
topological conditions or distance from the transmitter, a repeater is used to extend
transmission range. In the downlink path, the repeater picks up the signals from a donor
antenna of a BTS/ Node B, amplifies and re-transmits it into the required dark spot. In
the uplink path the signal picks up the signals from a mobile/ User Equipment (UE) and
re-transmits it to the BTS/ Node B.
2.2. THE MRx18 miniRepeater
Note: The MRx18/x18(/x18) and MRx18/y18(/y18) is shortly denominated as
MRx18 in the following.
Andrew MRx18 miniRepeater gives designers a simple tool to solve their small area
coverage and performance issues.
The MRx18 is easy to install. Also, a web-based GUI simplifies commissioning and
configuring the equipment. The RF link (donor) towards the base station is typically fed
from an outdoor antenna while the coverage area is fed by an indoor antenna. The
opportunity to adjust the passband of a repeater helps to cover any specific segment or
frequency band.
Due to modular design, the single-varia version MRx18 may be available as a dual-/
triple-varia segment or a dual-band-varia version in one cabinet. The dual-/ triplesegment MRx18/x18(/x18) is able to transmit two or three variable segments within one
frequency band. The dual-band MRx18/y18(/y18) supports two frequency bands, while
one variable segment is amplified in one frequency band and up to two variable
segments are dedicated for the other frequency band.
Auto Gain functionality enables automatic gain adjustment in order to maximize
performance, however gain may be set manually if desired.
An alarm interface with a display and LEDs indicates the status of the equipment locally.
Moreover, the status and alarms of the MRx18 can be queried via the web-based GUI.
The MRx18 has an optional remote-monitoring function that provides equipment
alarming and basic configuration settings via a GSM-SMS. Alarm SMSs (including
heartbeat) can be forwarded to the common Andrew OMC or to any standard SMS
receiver (even a mobile phone). Moreover, the MRx18 can be connected to LAN.
Page 13
Features at a glance
Up to three variable segments within one frequency band, or up to three variable
segments allocated in two frequency bands
Easy to install due to light weight, small dimensions and Auto Gain functionality
Integrated combiner/ crossband coupler, no external devices required, common
antenna ports for all bands/ segments equipped
Easy commissioning via web-based GUI
Automatic Level Control (ALC)
Variable bandwidth
LEDs for local alarm indication
RSSI and status indication via display
Optional remote control via SMS
Connection to LAN
Remote alarming through SNMP alarm traps
Compliant with all regulatory agencies (e.g. GSM 05.05, 3GPP and FCC)
Page 14
M0139ACD.doc
3 Functional Description
3. FUNCTIONAL DESCRIPTION
3.1. GENERAL
The name of a specific MRx18 miniRepeater reflects the frequency range in which it
operates (e.g. MR918 => 900 MHz frequency range). The operation principle of the
dual- and triple-segment is depicted in the following two block diagrams:
E0783B8
E0783BA
Page 15
E0783BB
E0783BC
Page 16
M0139ACD.doc
3 Functional Description
Coverage antenna
SMA connector RF mobile
Ethernet
connector
Reset and
installation
assistance
switch
DC PSU connector
Donor antenna
SMA connector RF BTS
Modem connector
DC + Data
Modem
SMA connector RF
Page 18
M0139ACD.doc
MRx18
miniRepater
Wall-mounting bracket
Wall
1. Fasten the wall-mounting
bracket by means of 2
appropriate screws (through
the pressed-in thread nuts) to
a wall. (The screw type
depends on the quality of
your wall).
Wall
behind
bracket
2 thread nuts
rear side
Wall
front side
2 M5x50 screws
) Note:
1. Connect the antenna cables to the antenna connectors and the antennas.
2. Use only the power supply delivered with the unit. Do not modify the power supply
unit (PSU) and cable!
Do not mount the PSU to the ceiling!
Connect the DC connector of the power supply and provide mains to the power
supply. Ensure the DC connector is plugged in correctly as in the following
illustrations.
Lug
Guide of DC connector
Insert with
arrow-moulded
side on top
Locking sleeve
Lug
Page 20
M0139ACD.doc
Page 21
Page 22
M0139ACD.doc
5 Software Setup
5. SOFTWARE SETUP
5.1. LOGIN
Click the
MRx18
MRx18 *
Please note that passwords are case-sensitive when entering
"MRx18"!
button.
If an incorrect username or password has been entered, the following error / attention
message appears:
"You have entered the wrong password. Please check the correct usage of upper
and lower cases or check the CAPS LOCK key on your console."
This message prompts to insert your username or password anew. Click key F5 to
refresh the login mask.
Page 23
Page 24
M0139ACD.doc
5 Software Setup
Explanation
The first button is Contrast Click this button to have the webpage displayed in
high contrast. To switch back into default contrast, just click on the button again
and the webpage will be displayed in default contrast again.
High-contrast webpages are available for each of the Status, Settings, and
Maintenance pages (see also illustrations in the following chapters).
The second button is Help. This button provides context-sensitive help to the
Status, Settings and Maintenance pages. By clicking this button, a help page for
detailed information will be opened immediately.
Separate Help pages are available for the Status, Settings, and Maintenance
pages.
The third button is Logout. Click this button to logout and quit the session,. Then
the logout page will be opened (see chapter 5.7 Logout).
STATUS BAR
Description
Displays the unit location of the MRx18 repeater - user defined area
entered in chapter 5.5.3 Settings - Modem Control or in chapter 5.5.4
Settings - LAN Connectivity.
Displays the designation of the repeater: MRx18 - user defined, entered in
chapter 5.5.4 Settings - LAN Connectivity.
Displays the Identification Number of the MRx18 repeater.
Displays the Serial Number of the MRx18 repeater.
Displays the actual repeater IP address set: 192.168.1.1.
Displays the current software version installed.
Displays the current version of the Graphical User Interface (GUI).
Displays the specific repeater type of the MRx18.
5.4. STATUS
Tabs
Menu bar
Menu bar
Explanation
This button updates the values of the Status page once.
By clicking this button, the values of the Status page are automatically
updated every 3 seconds.
Auto Refresh is deactivated by pressing this button once again or by leaving
the Status page.
Page 26
M0139ACD.doc
5 Software Setup
Parameter
Band
Actual Gain (dB)
DL/ UL
Output Power (dBm)
DL / UL
ALC DL / UL
Current Consumption
Temperature
Status
Description of General
Depending on the repeater model, the respective bands
equipped are displayed.
The actual UL and DL gain is shown, even if Auto Gain is
activated.
The actual measured output power in DL and UL is shown, for
low output power levels "<-10.0" is displayed.
For DL output power, the composite output power of all segments
within a frequency band is stated. For indication of output power
of a single segment, the other segments must be powered down.
The actual DL input level at the donor antenna port is indicated.
For more than one segment per frequency band the highest input
level is always displayed. If RSSI of a certain segment is
required, the other segment(s) must be powered-down.
The condition of the ALC is displayed herein. When ALC is
active, the ALC limit is stated in brackets, e.g. "active (18)".
Shows if the current is within the pre-defined limits.
The current temperature condition is displayed. When
temperature raises above 80 C, an alarm is generated and the
RF section of the repeater is powered down until normal
temperature is reached.
Page 27
Status
Description of Alarms
Parameter
Band
Local Oscillator
RSSI Level
ALC
DL/ UL
Parameter
Current Alarm
Temperature
Cause
Solution
Depending on the repeater model, the respective bands equipped are
displayed.
Restart repeater. If the error persists, contact
The LO does not lock.
technical support.
Input signal level too
Check antenna alignment, donor antenna and
low.
antenna cables.
Decrease gain, set "Auto Gain enabled" or
Input power too high.
decrease input power with external attenuators.
Cause
Power consumption is not
within the defined range.
Temperature too high
(>80C)
Description of Alarms
Solution
Restart repeater. If the error persists, contact
technical support.
Check installation location of MRx18 and
improve ventilation.
Page 28
M0139ACD.doc
5 Software Setup
5.5. SETTINGS
In the Settings pages - the second tab in the menu bar - current information on settings
of all parameters is shown. The settings of these parameters can be changed in those
pages.
The sub-tabs of the Settings page are the following:
-
Radio Frequency
Alarms
Modem Control
LAN Connectivity
User Account
Button
Explanation
Each setting applied on the Settings pages will only become valid by clicking
this button. Then all changes made will be saved to the repeater.
Buttons
Page 29
Parameter
Band
Power
Radio Frequency
Description of Power
Depending on the repeater model, the respective bands equipped are
displayed.
To power on, check "Power ON Band MRx18"
Uncheck "Power ON Band MRx18" to power down the RF-section of the
respective band. The band that is powered down is not visible in the Settings
page. Alarms and status information are not captured in the Status page
while the band is switched off.
Page 30
M0139ACD.doc
5 Software Setup
Parameter
Band
Passband (MHz) *
DL / UL
Radio Frequency
Description of General
Depending on the repeater model, the respective bands equipped are
displayed.
Enter the frequency range (start and stop frequency) for both DL and
UL to be amplified. User band is set for DL. Enter the frequency
values within the duplexer range DL that is indicated above the field.
For more than one segment within a frequency band, frequency
overlapping must not appear. Step size is 10 kHz. Recommended
bandwidth for UMTS networks:
1 UMTS carrier: 4.6 MHz
2 UMTS carriers: 9.6 MHz
3 UMTS carriers: 14.6 MHz
Parameter
Auto Gain
Radio Frequency
Description of General
With Auto Gain activated, the repeater will automatically set its gain to
the max. value. Depending on the DL input level, gain is decreased to
optimize the output power to the value adjusted at the Max. Output
Power (dBm) DL without reaching the ALC level. Gain is increased after
the time selected at Auto Gain Time Interval has expired, when the DL
input level decreases. UL gain is set accordingly with respect to Auto
Gain imbalance setting.
Page 31
Parameter
Maximum Output
Power (dBm) DL /
UL
Radio Frequency
Description of General
The ALC limit level or max. output power can be selected for DL and
UL independently.
The UL output power can be entered per segment, but the sum of
output power values entered per frequency band must not exceed the
composite output power stated in the specification of the single-band
manual of each repeater, with respect to the triple-/ dual-segment or
dual-band, (see chapters 8.1.1 and 8.1.2 in this manual).
The DL output power states the value of the composite output power,
the values in the data sheets have to be considered, too.
Example: MR918/918/918:
Output power according to single-band datasheet: +18 dBm composite
According to triple-segment data sheet no degradation of output power
Setting Max. Output power DL: + 18 dBm
Setting Max. Output power UL :
equal distribution: Segment 1 => +14 dBm
Segment 2 => +14 dBm
Segment 3 => +14 dBm
calculation: 18 dB 10 log 3 = 13.23 dBm
round up to 14 dBm
unequal distribution
(assumption: Segment 1 => 25%)
Segment 2 => 25%
Segment 3 => 50%)
Segment 3: +15 dBm
Segment 2: +12 dBm
Segment 1: +12 dBm
Depending on application/ network, the output-power value stated in
the datasheet must be considered in order to meet the respective
standards.
ETSI refers to the standards meeting <-36 dBm or <-30 dBm
Intermodulation products. For output power values outside the scale
marked with ETSI, the intermodulation products are <-13 dBm.
Page 32
M0139ACD.doc
5 Software Setup
Parameter
Band
UL/ DL
Inbalance (dB)
Radio Frequency
Description of Auto Gain *
Depending on the repeater model, the respective bands equipped are
displayed.
When Auto Gain is enabled, the gain is adjusted automatically. With an
entry in the Auto Gain imbalance field UL/DL Inbalance (dB), the UL gain
is decreased compared to the DL gain for this value.
Possibility to select between three behaviours of Auto Gain:
0 s/24 h: Gain is reduced without latency time in case of too high input
power. Every 24 hours the repeater tries to increase gain by 1 dB to max.
output power in case input power has decreased again.
Time Interval
0 s/12 h: See above, but the interval for a try to increase gain again is 12
hours.
10 s/12 h: Gain is reduced after a latency time of 10s in case of too high
input power. Interval for a try to increase gain again is 12 hours.
With Auto Gain activated, two different behaviours of Auto Gain can be
chosen from:
Mode
Uniform Gain:
Gain of each segment within a frequency band assigned with "Uniform
Gain" is set according to the highest DL input signal, i.e. all input levels of
segments operating in "Uniform Gain" are compared, depending on the
highest level, the gain is set accordingly. Gain Mode might be chosen if
frequency hopping is done between the segments for instance.
Indpendent Gain:
Gain of segments assigned with "Independent Gain" is set individually in
order to get the max. output power, independent of other segments
operating in the same frequency range. For example, "Independent Gain"
might be chosen if different services, e.g. GSM900 and UMTS900, are
transmitted on a separate frequency segment allocated in one frequency
band.
button.
Page 33
Parameter
ALC UL/DL
RSSI Level
Current Alarm
Local Oscillator
Temperature
Alarms
Description of Severity
A severity level can be assigned to each alarm. It is also possible to
disable alarms. The severity of alarms may be:
disabled , warning, minor, major, critical
button.
M0139ACD.doc
5 Software Setup
Page 35
Parameter
Modem Type
Software
Version
SMSC
Destination
Phone Number
Unit Location
Unit ID
Heartbeat
Interval
Time to Next
Heartbeat
Alarming via
SMS
Page 36
M0139ACD.doc
5 Software Setup
Page 37
Parameter
DHCP
Alarming via
SNMP
Repeater Name
Page 38
M0139ACD.doc
5 Software Setup
Parameter
IP Address
Subnet Mask
Standard
Gateway
Primary DNS
Server
1)
2)
) Note:
Parameter
Destination IP
Address
Unit Location
3)
if polling or disabled is selected at item General - Alarming via SNMP, these parameters cannot be
accessed.
button.
Page 39
Parameter
Username
New Password
Repeat Password
To login the user name is required. The default user name can be changed.
Max. 8 characters are allowed. *
The password to login can be changed. Max. 8 characters are allowed. The new
password has to be repeated. *
Page 40
M0139ACD.doc
5 Software Setup
5.6. MAINTENANCE
Page 41
Parameter
Location Area
Code
MCC / MNC
Cell Information
RSSI (dBm)
Software
Version
Maintenance
Description of Modem Debugging
The Location Area Code of the existing server cell is indicated. This
information is provided by the connected modem. No network is stated
in case no modem is connected or is recognized to/by the repeater or
the modem is not able to access to a mobile network.
The Mobile Country Code (MCC) and Mobile Network Code (MNC) of
the server cell is indicated. The first three digits show the MCC, the last
two digits the MNC. The MCC and MNC are detected by the connected
modem. No network is stated in case no modem is connected or is
recognized to/ by the repeater or the modem is not able to access to a
mobile network.
The cell information displays the ID of the cell the modem is served. No
network is stated in case no modem is connected or is recognized to/by
the repeater or the modem is not able to access to a mobile network.
The received signal level at the antenna port of the modem is displayed.
The loss of -22 dB of the modem coupler integrated in the repeater is
considered. No network is stated in case no modem is connected or is
recognized to/by the repeater or the modem is not able to access to a
mobile network.
The software version of the modem connected to the repeater is shown.
If no modem is connected or the modem can not be recognized, the
message "no valid modem found" appears.
Parameter
Guide for Windows
Maintenance
Description of Software Update
The procedure how to update the repeater software update herein.
Page 42
M0139ACD.doc
5 Software Setup
Parameter
Choose .bin file
Maintenance
Description of Webpage Update
The webpages can be updated by uploading the .bin file.
Choose the bin file by clicking Browse and then click Upload to
upload and update the webpage.
5.7. LOGOUT
button, the session will be quit and the Login page opened,
Logout is possible from the Status, Settings, and Maintenance pages at any time.
) Note: Certain settings made (e.g. in LAN Connectivity, User Account) will only
become valid after the user has executed a manual logout.
Page 43
5.8.
Page 44
M0139ACD.doc
6 Optional Equipment
6. OPTIONAL EQUIPMENT
6.1. EXTERNAL MODEM (KIT)
As an option, the MRx18 miniRepeater can also be equipped with an external modem
for SMS alarm forwarding (including heartbeat) and to A.I.M.O.S. or an SMS receiver.
Several modems are available as kits; for their exact designation please see chapter 8.4
Spare Parts List.
Further information is available in a separate manual, which is also part of this CD
delivered.
Moreover, settings can be changed by commands sent from A.I.M.O.S. or an SMS
receiver.
6.2. ANTENNA
An
omni-directional
multi-band
coverage antenna can be directly
mounted to the MRx18 antenna port
(labelled Mobile) as illustrated to the
right.
Coverage
antenna
Page 45
Page 46
M0139ACD.doc
Display
Alarm
LEDs
Orange
Status
Red
Blinking
red/ green
ALC
Off/ red
Blinking red
Function/ Indication
If the LED is off, the respective MRx18 does not receive any
DC power.
A green light indicates the normal operation of the repeater.
Power is present and the current consumption of the unit is
within the specifications.
An orange light indicates that current consumption of the
repeater is not within defined limits or the LO cannot lock and
the repeater might not work properly. Faulty segment(s) is (are)
identified on the display.
A red light indicates the temperature alarm, which switches to
power-down mode once an over-temperature has been
reached.
The temperature sensor of the controller will continue to check
the temperature in power-down mode. As soon as the
temperature has returned to normal, the controller will enable
the RF-section.
Blinking red/ green indicates the antenna alignment assistance
for approx. 4 minutes.
A red LED indicates that the input power received by the
repeater is too high. The output power of the repeater must be
limited. This will be done by the ALC. Limitation of power
ensures that the final stage is not overdriven and that
intermodulations are kept below the limits. The segment(s)
where the ALC is activated is (are) identified in the display.
The LED is blinking red for 4 seconds during the boot process.
Page 47
Denotation
Colour
of LED
Ethernet
Off/ green
Function/ Indication
The LED is green if the repeater is connected via Ethernet.
LED is blinking during data transfer via Ethernet connection.
Alarm
LEDs
figure 7-2 Display with reset button and alarm LEDs , exemplary
Functions of the Reset Button:
To align the donor antenna of the MRx18 towards the BTS via the antenna
alignment assistance (as described in chapter 4.2 Electrical Installation), press the
"Reset and installation assistance" switch (illustrated in figure above) for at least
four seconds after (!) the boot process has been finished (i.e. red ALC LED is
blinking for four seconds). This will set the gain to max. value and disable Auto
Gain for about 4 minutes. The status LED will be blinking red/green. Align the
donor antenna towards the BTS/ Node B tower to reach the highest RSSI level
possible. Check the RSSI level at the display (see chapter 7.2 Display and Reset
& Installation Assistance Button). After four minutes the gain and Auto Gain are
adjusted to the values prior to the activation of the antenna alignment.
To reset Ethernet settings, username and password to the default factory
settings, press the Reset and installation assistance switch during the boot
process (i.e. red ALC LED is blinking for four seconds after power has been
supplied) and keep the switch pressed until the boot process starts again
(Ethernet LED starts blinking). It is not possible to execute a reset when a local
connection is established.
Page 48
M0139ACD.doc
Page 49
Page 50
M0139ACD.doc
8 Appendix
8. APPENDIX
8.1. ELECTRICAL SPECIFICATIONS MRx18
8.1.1. MRx18/x18 Dual-Segment/ MRx18/x18/x18 Triple-Segment
The electrical specifications of the MRx18 miniRepeater are basically identical to the
ones of the MRx18 single-band (see separate manual, which is also part of the CD
delivered). Deviations are stated in the following:
Existing dual- / triple-segment versions *:
MR918/918/918
MR918E/918E/918E
MR918/918
MR918E/918E
MR1818/1818
MR1818/1818/1818
MR1718/1718/1718
MR1918/1918/1918
MR2118/2118
Bandwidth
Power supply
Power consumption
Antenna port
Page 51
MR8018
MR8518
MR918
Extension Cabinet
MR1718
MR1818
MR1918
X
X
MR2118
X*
X
X*
Bandwidth
Mains power
Local power
Power consumption Two segments
Three segments
Antenna port
Connector
Return loss
Indoor multiband antenna
Antenna gain
Power supply
Page 52
M0139ACD.doc
8 Appendix
) Note:
+5C to +40C
IP30
) Note:
MR918/918
MR918/918/918
MR918E/918E
MR918E/918E/918E
MR2118/918
MR2118/2118
MR2118/918/918
MR1818U/918
MR1818U/918/918
MR1818L/918
MR1818L/918/918
MR1818L/1818L
MR1818U/1818U
MR1818L/1818L/1818L
MR1818U/1818U/1818U
MR1718/1718/1718
MR1918/1918/1918
MR8018/1918/1918
MR8518/1918/1918
MR1718/1918/1918
Manuals for MRx18 Rel. 2
Antenna 824-960 1710-2500
RF Cable-Kit SMA to N 500 mm
Modem-Kit HC25
Modem-Kit MC35
Modem-Kit MC55 MRx18
Modem-Kit AEGS5-T MRx18
Page 54
ID No:
7580518
7579763
7600416
7600415
7602831
7602829
7579755
7602828
7602827
7596747
7596746
7602825
7602826
7602823
7602824
7613707
7613706
7613709
7613708
7613705
7598133-00
7579858
7594320
7598812
7598816
7598817
7615377
M0139ACD.doc
8 Appendix
7565922
7604783
7565820
7565923
7565924
7565921
Last Replaceable Unit (LRU) is the entire miniRepeater MRx18 listed above, except for
the manual, the power supply kits and the optional equipment (antennas, RF cable kit
and modem kits) listed above.
The manufacturer reserves the right to replace the spare parts listed above by
equivalent substitutes!
Page 55
Page 56
M0139ACD.doc
9 Index
9. INDEX
A
Abbreviations............................................................. 7
Adapter Cable.......................................................... 45
Address of Andrew Wireless Systems GmbH.......... 12
Alarm LEDs ............................................................. 47
Alarming Interface
Functional Description ........................................ 47
Status ................................................................. 28
Alarms ..................................................................... 28
Alarms (Setting)....................................................... 34
Andrew Solutions..................................................... 10
Antenna ................................................................... 45
Apply ....................................................................... 29
Auto Gain .......................................................... 31, 33
Auto Refresh............................................................ 26
Installation
Electrical ............................................................. 20
Mechanical.......................................................... 19
Installation
Antenna Alignment Assistance ........................... 21
Installation
Software Settings................................................ 23
Introduction.............................................................. 13
IP Address ............................................................... 21
C
Connector (DC) ....................................................... 20
Connectors .............................................................. 17
Contact Addresses .................................................. 11
Contrast (High) Page............................................... 25
Contrast Button........................................................ 25
Coverage Antenna................................................... 45
Customer Support Addresses.................................. 11
L
LAN Connectivity ................................... 37, 38, 39, 40
LEDs........................................................................ 47
Login.................................................................. 23, 43
Logout................................................................ 25, 43
M
Maintenance ............................................................ 41
Menu Bar
Buttons................................................................ 25
Menu Bar ................................................................. 25
Modem (External) .................................................... 45
Modem Control ........................................................ 35
D
DC Connector.......................................................... 20
Declaration of Conformity ........................................ 10
Design ..................................................................... 17
DHCP Settings ........................................................ 39
Display..................................................................... 48
O
Optional Equipment ................................................. 45
P
Password................................................................. 40
F
Functional Description ............................................. 15
H
Health and Safety Warnings ...................................... 8
Help ................................................................... 25, 41
R
Radio Frequency
Auto Gain............................................................ 33
General ............................................................... 31
Refresh .................................................................... 26
Reset Button............................................................ 48
Reset to Default....................................................... 22
Page 57
S
Set
Auto Gain............................................................ 33
Auto Gain............................................................ 31
Gain .................................................................... 31
Output Power...................................................... 32
Power-Down ....................................................... 32
Settings ................................................................... 29
Alarms ................................................................ 34
LAN Connectivity ................................................ 37
Modem Control ................................................... 35
Severity ................................................................... 34
SMS Alarm Forwarding ........................................... 45
SNMP Settings .................................................. 39, 40
Software Settings .................................................... 23
Software Setup ........................................................ 23
Software Upload ...................................................... 44
Software Version ..................................................... 44
Spare Parts List ....................................................... 54
Specifications
Electrical (MRx18/x18 Dual-Segment) ................ 51
Electrical (MRx18/x18/x18 Triple-Segment)........ 51
Electrical (MRx18/y18 Dual-Band) ...................... 52
Electrical (MRx18/y18/y18 Dual-Band) ............... 52
Environmental and Safety................................... 53
Mechanical.......................................................... 53
Status ...................................................................... 26
Status Bar................................................................ 25
Supervision.............................................................. 47
System overview ..................................................... 13
T
Troubleshooting....................................................... 28
U
Upload Software ...................................................... 44
W
Web-based GUI....................................................... 23
Page 58
M0139ACD.doc
10 List of Changes
10.
LIST OF CHANGES
Version
M0139ACC
M0139ACD
Changes
- Chapter 3.2 modified
- Chapter 4.2 extended
- Chapter 5.1 updated
- Chapter 5.3 updated
- Chapter 8.4 extended
Release Date
11-November-2009
18-March-2010
Page 59