Measurement Specifications
Spectral Response:
Model
LT (Low Temp.)
8 to 14 microns
Optical Resolution:
LT
10:1, 22:1
Temperature Range:
Model
LT
-40C to 600C (-40F to 1112F);
-25C to 600C for J-thermocouple output
1% of reading or 1C,
whichever is greater
Thermocouple output accuracy
1% of reading or 2.5C,
whichever is greater
0.5% of reading or 0.5C (1F),
whichever is greater
System Accuracy:
R
S-232 or optional RS-485 digital communications
for remote setup and monitoring
System Repeatability:
Temperature Coefficient:
MID
0.15K per K or 0.15% per K,
MIC
0.05K per K or 0.05% per K
MIH
0.05K per K or 0.05% per K
whichever is greater*
Temperature Resolution:
LT
0.3C or 0.5F
System Response Time: 150ms (95%)
Emissivity:
Transmission:
Signal Processing:
Electrical Specifications
Outputs:
Alarm Relay:
Cable Length:
1m (3.2ft) standard,
3m (10ft), 8m (26ft) and
15m (50ft) lengths available
Output Impedance
(T/C output):
20 ohms
100K ohms
Current Draw:
100 mA
Power Supply:
12-24 VDC
Sensor Specifications
Environmental Rating:
Electronics housing
Storage Temperature:
Relative Humidity:
10 to 95%, non-condensing
Accessories / Options
Each standard MI package includes a sensing head, one
mounting nut, 1m (3.2ft) of cable, die-cast housing with
premounted electronics, and an operators manual. Longer
cables up to 15m (50ft) maximum are available and must be
specified at time of order.
Adjustable or fixed
mounting bracket for
sensing head (XXXMIACAB or
XXXMIACFB)
Construction:
Sensing head
Stainless steel
Electronics housing
Zinc, die-cast
Weight:
Sensing head (w/1 m cable) 50g (1.75oz)
Electronics housing
270g (9.5oz)
Shock IEC 68-2-27 (MIC ST 810D)-50gs, 11ms on any axis
Vibration 68-2-27 (MIC ST 810D)-3gs, 11-200Hz on any axis
Sensor Dimensions
Sensing Head
Preinstalled cable
standard cable length
1 m (3.2 ft) 5 (.2)
Electronics Housing
DataTemp Multidrop
software puts you in control.
Multidrop Network Installation
RS-485 sensors can be configured in a multidrop network or
point-to-point installation. In multidrop networks, a dedicated
PC with DataTemp Multidrop software supports online system
monitoring and configuration.
Model
Optics
Temperature
Range
Options
RAYMI
Model
RAYMI
Code A
Description
Modular Infrared Thermometer
Model
Standard model includes selectable 4-20mA/0-20mA, 0-5 V, or J/K thermocouple output and head temperature output
85C (185F) ambient operating range .15k/k temperature coefficient
MID with DKD/NIST calibration certificate and optimized performance 125C (257F) ambient operating range
.05k/k temperature coefficient
MID with DKD/NIST calibration certificate and optimized performance 180C (356F) ambient operating range
.05k/k temperature coefficient
Code B
10
20
Code C
LT
Code D
4
CB 3
CB8
CB15
V
Typical
Model
Number
Optics
10:1 D:S sensor with 1m wiring cable
22:1 D:S sensor with 1m wiring cable
Temperature Range
-40C to 600C (-40F to 1112F); 8 14 microns
Options
RS-485 communication for multidrop networks
3m (9.8) cable
8m (26) cable
15m (49) cable
Display window for electronics housing
RAYMIH10LTCB3
www.raytek.com
United Kingdom
Tel: +44 1908 630 800
[email protected]
China Headquarters
Beijing, China
Tel: 8610 6438 4691
[email protected]
To find a Raytek office near you, please visit www.raytek.com
Worldwide Service
Raytek offers services, including repair and calibration.
For more information, contact your local office or e-mail [email protected]