CashCodeone QuickReference Guide
CashCodeone QuickReference Guide
CashCode
+1 905-303-8874
1-800-584-2633
2013 Crane Payment Solutions
www.one.cashcode.com
[email protected]
Part No. OPT-FLS-FB, Rev 2.
CashCode
Getting Started:
My Bill Validator is not
working
Perform Self-Diagnostic
Troubleshooting (see page
13) or perform a Diagnostic
through a PC (see page 15) to
check for hardware issues
Perform Preventative
Maintenance (see page 9) to
keep the Bill Validator running
at top performance
CashCode
Diagnostic/Status LED
Software Version
Label: FLS-XXXX-XXXXXX
(See page 16 for
description)
Front Service USB Port
CashCode
TM
CashCode
Bill Validator
(Assembly w/o Cashbox)
Label: FLS-XXXX
Cashbox (Module)
Label: FLSC-XXXX*
Part
Number
Bill
Capacity
FLSC-0002*
600
FLSC-0202*
900
FLSC-0102*
1,000
FLSC-0001*
600
FLSC-0101*
1,000
FLSC-2500
2,500
Handle
Style
Housing
FLSH-XXXX
Flexible
FLSH-0003
Foldable
FLSH-0003
FLSH-0004
Cashbox Locks:
Standard Locking Hasps P/N - #5110086
Lock Size: Drum - 3/4 Length - 5/8 or 11/8
All Product Labels contain a generic part
number and unique serial number.
-4-
-5-
FUNCTION
GROUND BUS
POWER (VCC)
GROUND (GND)
RS485-A BUS
10
RS485-B BUS
11
12
13
POWER (0V)
14
15
16
17
18
19
POWER (12V/24V)
20
21
22
23
24
CashCode
CashCode
Preventative Maintenance
AFFECTED AREA
CLEANING PROCEDURE
CashCode
ON State
3 2 1
OFF State
PARAMETER
SWITCH
ON
OFF
Orientation of the
ticket
SW2.1
Bar Code
Four-Way
Bar Code
Face-Up
Stacker orientation
SW2.2
Down
Connectivity*
SW2.3
oneCheck
oneTrackTM
Mode
SW2.4
Service Mode
Host Mode
Up
TM
ON State
8 7 6 5 4 3 2 1
OFF State
PARAMETER
SWITCH
ON
OFF
Denomination #1
SW1.1
Enabled
Disabled
Denomination #2
SW1.2
Enabled
Disabled
Denomination #3
SW1.3
Enabled
Disabled
Denomination #4
SW1.4
Enabled
Disabled
Denomination #5
SW1.5
Enabled
Disabled
Denomination #6
SW1.6
Enabled
Disabled
Denomination #7
SW1.7
Enabled
Disabled
Acceptance Mode
SW1.8
Accept All
CashCode
Self-Diagnostic Troubleshooting
CashCodes oneTM Bill Validator is equipped with an automatic
self-diagnostic test to aid in repair and maintenance.
Step 1: Put the validator into service mode (see page 11 and turn the
power on to start the test.
RED FLASHES
ERROR
SOLUTION*
Cashbox is removed
from Bill Validator
Check if cashbox is
installed correctly
Cashbox is full/
ready for drop
Mechanical jam in
cashbox or stacker
failure
Failure of dielectric
sensor
- 13 -
RED FLASHES
ERROR
SOLUTION*
Failure of transport
motor
Transport motor
too fast
10
Failure of alignment
mechanism
11
See Solution 8
12
13
Overload of transport
motor
14
System error
FLICKER x2
Cashbox is Hot/
Machine number
mismatch
Antenna module or
cashbox failure
CashCode
CashCode
Software Updates
Software
FLS-XXXX-XXXXXX-XX
(1)-(2)(3)-(4)(5)(6)-(7)
(1) ONE Bill Validator Memory card
(2) Country code (ISO 3166-1)
(3) Protocol/OEM customization
(4) Control firmware
Software Version
(5) Validation firmware
(6) C/Code Software Configuration
(7) Optional extensions indicating type of memory card.
Possible memory card extensions:
(___)
(-OP)
(-99)
Allows up to 99 downloads
CashCode
Software Updates
THIS SIDE UP
- 17 -
ERROR
SOLUTION*
Repeat Procedure
Security error
CashCode
- 19 -
and
Setting Machine/Location Number:
1. Connect your Bill Validator to a PC computer using a
USB cable, as described on page 15
2. Launch the SMNUtility.exe utility
3. Press Connect to establish communication with the
validating head 1
4. Enter a Machine and/or Location Number as well as the
Cashbox Size (default is 600), and transfer it to the
validating head. Check the output on the utility user
interface to verify correctness 2
5. Once ``Disconnect`` has been pressed, the computer
time and date will be set on the unit.
2
4
Report Type
Details
Revenue Report
Cashbox Full
Zero Revenue
Scheduled/Arrived
Missing Machine/
Location numbers
Bill Validator
acceptance/
performance
Version
Group
Access
Export
Dashboard
- 22 -
Search
IGT
Printer Harness
Cable Part Number
WMS
150-00106-100
150-00199-100
CashCode One
Harness Cable Part
Number
150-00123-100
FL85.00.056
Printer Software
BV Control
Software
Others
58 +
65 +
65 +
To Host
CashCode one
Bill Validator
Future Logic
Printer
- 23 -
Printer Harness
Cable
All
Printer Harness
Cable Part Number
95-11683L
CashCode Harness
Part Number
Not Required
Printer SW
BV Control SW
SP 3 +
58 +
66 +
Transact Printer
66 +
CashCode one
Bill Validator
- 24 -
The oneCheck printer can generate three different reports (these are
either printer automatically or manually, based on setting from page 21):
EXAMPLE
Bill Validator
and Printer
Performance
Report
Cashbox Audit
and
Performance
Report
(CAPR)
* Patent Pending
Cash Management
1. PRINT CAPR
2. DROP
4. ANALYZE
3. SCAN and
REPORT ASSET
CAPR Guidelines
EVENT
RECOMMENDED DIRECTIONS
Jam in Bill
Validator
Exchanging
validating head
from one machine
to another
Cashbox Full/
Emergency Drop
Standard Drop
Operation
EVENT
DIRECTIONS
Drop during
power cycle down
or Machine out of
order
Scanning of
multiple CAPR
reports per
Cashbox into
Database
Bill
Validator
Firmware
Update
CashCode
600
900 1000
2500
E-Mail: [email protected]
E-Mail: for RMA: [email protected]
or call our Technical Support line at:
+1 905-303-8874 or toll free in NA 1-800-584-2633
2720 Steeles Ave. West, Concord, ON Canada L4K 4S3