GEP80SP4

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

GEP80SP4

Diesel Generator Set


Exclusively from your Cat dealer

EU Stage II Emissions Compliant

Output Ratings
Prime*

Standby*

72.0 kVA

80.0 kVA

72.0 kW

80.0 kW

82.0 kVA

90.0 kVA

82.0 kW

90.0 kW

Generating Set Model


220-240V, 50 Hz

240/120V, 60 Hz

* Refer to ratings definitions on page 4.


Ratings at 1.0 power factor.

Technical Data
Engine Make & Model:

Perkins 1104C-44TAG2

Alternator Model:

LL3014F

Base Frame Type:

Fbc2 - (08Hr)

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz

60 Hz

Engine Speed: RPM

1500

1800

Fuel Tank Capacity: litres (US gal)

250 (66.0)

Fuel Consumption, Prime: l/hr (US gal/hr)

21.0 (5.5)

25.7 (6.8)

Fuel Consumption, Standby : l/hr (US gal/hr)

23.5 (6.2)

28.4 (7.5)

Engine Techncial Data


Physical Data

Lubrication system
Perkins

Manufacturer:
Model:

Oil Filter Type:

1104C-44TAG2
4 / In Line

No. of Cylinders/Alignment:

4 Stroke

Cycle:
Induction:

Turbocharged Air To Air


Charge Cooled

Cooling Method:

Spin-On, Full Flow

Total Oil Capacity l (US gal):

8.0 (2.1)

Oil Pan l (US gal):

7.0 (1.8)

Oil Type:

API CC/SE

Cooling Method:

Water

Water

Governing Type:

Electronic

Governing Class:

ISO 8528 G2
18.3:1

Compression Ratio:
Displacement: l (cu.in)

4.4 (268.5)

Bore/Stroke: mm (in)

105.0 (4.1)/127.0 (5.0)

Moment of Inertia: kg m (lb. in)

1.51 (5160)

Engine Speed: RPM


Gross Engine Power: kW (hp)
-Standby:
-Prime:

12/Negative

-Battery Charger Amps:

65

Weight: kg (lb) - Dry:

500 (1102)

- Wet:

520 (1146)

50 Hz

60 Hz

Air Filter Type:

Replaceable Element
-Standby:

6.3 (221)

7.8 (275)

-Prime:

6.0 (212)

7.8 (274)

Max. Combustion Air Intake


Restriction: kPa (in H2O)

8.0 (32.1)

8.0 (32.1)

Radiator Cooling Air Flow:


m/min (cfm)

187.8 (6632) 244.2 (8624)

External Restriction to
Cooling Air Flow: Pa (in H2O)

Cooling System

125 (0.5)

125 (0.5)

Water Pump Type:

103.0 (138.0)

117.5 (158.0)

93.6 (126.0)

106.8 (143.0)

1873.0 (271.7) 1781.0 (258.3)


1702.0 (246.9) 1619.0 (234.8)
8.2

13.8

Fuel System
Replaceable Element

Recommended Fuel:

Class A2 Diesel
Fuel Consumption: l/hr (US gal/hr)
110%
Load

100%
Load

75%
Load

50%
Load

50 Hz

23.5 (6.2)

21.0 (5.5)

15.8 (4.2)

11.0 (2.9)

60 Hz

28.4 (7.5)

25.7 (6.8)

19.2 (5.1)

13.7 (3.6)

50 Hz

23.5 (6.2)

17.4 (4.6)

12.0 (3.2)

60 Hz

28.4 (7.5)

21.0 (5.5)

14.7 (3.9)

Prime

Standby

(based on diesel fuel with a specific gravity of 0.85 and conforming to


BS2869, Class A2)

50 Hz

60 Hz

17.5 (4.6)

17.5 (4.6)

Cooling System Capacity:


l (US gal)

1800

-Prime:
Regenerative Power: kW

Combustion Air Flow:


m/min (cfm)

1500

-Standby:

Fuel Filter Type:

Air System

60 Hz

BMEP: kPa (psi)

Engine Electrical System:


-Voltage/Ground:

50 Hz

Performance

Centrifugal

50 Hz

Exhaust System
Silencer Type:

Industrial

Silencer Noise Reduction

SD50 (1)

Pressure Drop Across


Silencer System: kPa (in Hg)

Heat Rejected to Water &


Lube Oil: kW (Btu/min)

60 Hz

2.10 (0.620) 3.21 (0.948)

Silencer Noise Reduction


Level: dB

-Standby:

50.7 (2883)

64.0 (3640)

-Prime:

46.1 (2622)

57.7 (3281)

Heat Radiation to Room:


kW (Btu/min)
-Standby:

7.5 (427)

9.4 (535)

Exhaust Gas Flow:

-Prime:

6.8 (387)

8.5 (483)

m/min (cfm)

2.8 (3.8)

4.8 (6.4)

Radiator Fan Load: kW (hp)

22

17

18.0 (5.3)

15.0 (4.4)

-Standby:

15.0 (530)

18.0 (636)

-Prime:

14.0 (494)

17.0 (600)

-Standby:

494 (921)

517 (963)

-Prime:

463 (865)

469 (876)

Max. Allowable Back


Pressure: kPa (in. Hg)

Exhaust Gas Temperature: C (F)


m/min (cfm)
Cooling system designed to operate in ambient conditions up to 50C
(122F). Contact your local Olympian dealer for power ratings at specific
site conditions.

Consult your Olympian representative for more information

Alternator Performance Data


50 Hz
Data Item

240V

Motor Starting
Capability* kVA

230V

60 Hz

220V
220V/110V

240V/120V

285

269

254

223

252

Xd

1.625

1.769

1.934

2.640

2.220

X'd

0.098

0.106

0.116

0.160

0.130

X''d

0.058

0.063

0.068

0.090

0.080

Short Circuit
Capacity** %

Reactances:
Per Unit

Reactances shown are applicable to standby ratings.


* Based on 30% voltage dip.
** With optional Permanent Magnet generator or AREP excitation.

Alternator Technical Data


Physical Data
Manufacturer:
Model:

Operating Data
OLYMPIAN
LL3014F

Overspeed: RPM

2250

Voltage Regulation (steady state) (%):

+/- 0.5

No. of Bearings:

Wave Form NEMA = TIF:

Insulation Class:

Wave Form IEC = THF:

2.0%

Total Harmonic Content LL/LN:

4.0%

Winding Pitch - Code:


Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:

2/3 - 6
12
IP23
SHUNT
R250

Radio Interference:

50

Supression is in line with European


Standard EN61000-6

Radiant Heat: kW (Btu/min)


-50 Hz:

12.6 (717)

-60 Hz:

16.8 (955)

Consult your Olympian representative for more information

Technical Data

1 Phase Ratings and Performance at 50 Hz, 1500 RPM

Voltage

1 Phase Ratings and Performance at 60 Hz, 1800 RPM

Voltage

Standby

Prime
kVA

kW

kVA

kW

240V

72.0

72.0

80.0

80.0

230V

72.0

72.0

80.0

80.0

220V

72.0

72.0

80.0

80.0

Prime

Standby

kVA

kW

kVA

kW

220V/110V

82.0

82.0

90.0

90.0

240V/120V

82.0

82.0

90.0

90.0

Weights & Dimensions


Weights: kg (lb)

Dimensions: mm (in)

Net (+ lube oil)

1292 (2849)

Length

2089 (82.2)

Wet (+ lube oil & coolant)

1310 (2888)

Width

1120 (44.1)

Fuel, lube oil & coolant

1522 (3355)

Height

1367 (53.8)

Note: General configuration not to be used


for installation.
See general dimension
drawings for detail.

Definitions

General Data

Standby Rating

Documents

These ratings are applicable for supplying continuous electrical


power (at variable load) in the event of a utility power failure. No
overload is permitted on these ratings. The alternator on this model
is peak continuous rated (as defined in ISO 8528-3).

A full set of operation and maintenance manuals and circuit wiring


diagrams.

Prime Rating

BS4999, BS5000, BSEN60034, BSEN61000, IEC60034.

These ratings are applicable for supplying continuous electrical


power (at variable load) in lieu of commercially purchased power.
There is no limitation to the annual hours of operation and this
model can supply 10% overload power for 1 hour in 12 hours.

Warranty

Quality Standards

All equipment carries full manufacturer's warranty.

Standard Reference Conditions


Note: Standard reference conditions 25C (77F) air inlet temp,
100m (328ft) A.S.L. 30% relative humidity. Fuel consumption data
at full load with diesel fuel with specific gravity of 0.85 and
conforming to BS2869: 1998, Class A2.

Market: International
LEHF0126-00

Information contained in this publication may be considered confidential.


Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
CAT, CATERPILLAR, their respective logos OLYMPIAN, ''Caterpillar Yellow'' and the "Power Edge" trade dress, as well as
corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

www.CAT-ElectricPower.com
2010 Caterpillar
All rights reserved.
Printed in U.S.A.

You might also like