g1142 Us 0310 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 192

Intelligent Drivesystems

NORD GEAR - 92 SERIES BEVEL GEARMOTORS & SPEED REDUCERS

WEST
Corona, CA (Los Angeles)
Phone: 608.849.0190

MIDWEST
Waunakee, WI (Madison)
Phone: 608.849.7300

EAST
Charlotte, NC
Phone: 608.849.0140

NORD Gear Limited


Toll-Free in Canada: 800.668.4378
[email protected]
CANADA
Brampton, ON (Toronto)
Phone: 905.796.3606

Durable & Premium Efcient Gear Units

G1142

www.nord.com

NORD Gear Corporation


National Customer Service Toll-Free: 888.314.6673
[email protected]

100200106/0310

DRIVESYSTEMS

92 SERIES BEVEL
GEARMOTORS & SPEED REDUCERS
G1142

DRIVESYSTEMS

92 Series Bevel
Innovative Design

Product
Overview
We can match our NORDAC Frequency Inverters with our Inverter/Vector Duty Motors and
UNICASE Speed Reducers to provide a total AC Motor Drive solution from one trusted source.

FOOT-MOUNT
GEARMOTOR

UNICASE SPEED REDUCERS


HELICAL IN-LINE
- Foot or Flange Mount
- Torque up to 205,000 lb-in
- Gear ratios 1.82:1 to over 300,000:1
NORDBLOC HELICAL IN-LINE
- Foot or Flange Mount
- Torque up to 26,550 lb-in
- Gear ratios 1.88:1 to over 370:1

PARALLEL HELICAL CLINCHER


- Shaft, Flange or Foot Mount
- Torque up to 797,000 lb-in
- Gear ratios 4.26:1 to over 300,000:1

FOOT-MOUNT REDUCER
NEMA C-FACE INPUT

RIGHT ANGLE
HELICAL-BEVEL 2-STAGE
- Foot, Flange or Shaft Mount
- Torque up to 5,840 lb-in
- Gear ratios 4.1:1 to 72:1

FLANGE-MOUNT REDUCER
GEARMOTOR &
SOLID OUTPUT SHAFT

RIGHT ANGLE HELICAL-BEVEL


- Foot, Flange or Shaft Mount
- Torque up to 283,000 lb-in
- Gear ratios 8.04:1 to over 300,000:1
RIGHT ANGLE HELICAL-WORM
- Foot, Flange or Shaft Mount
- Torque up to 27,585 lb-in
- Gear ratios 4.40:1 to over 300,000:1

FOOT-MOUNT
SOLID INPUT SHAFT &
DOUBLE OUTPUT SHAFT

DRIVESYSTEMS

FLEXBLOC WORM
- Modular bolt-on options
- Torque up to 4,683 lb-in
- Gear ratios 5:1 to 3,000:1

HIGH PERFORMANCE
MOTORS & BRAKEMOTORS
INVERTER/VECTOR DUTY
- Standard or Energy Efficient
- Integral, NEMA or Metric IEC
- 1/6 to 250 hp

NORDAC
INVERTER/VECTOR DRIVES
TRIO SK300E
- Motor or remote mounted
- IP55 washdown
- 380-460V, 3-phase, to 5hp
- 200-240V, 3-phase, to 3hp
SK500/520/530E
- Compact, high performance
- 380-480V, 3-phase, to 10hp
- 200-240V, 3-phase, to 5hp
- 200-240V, 1-phase, to 3hp
- 110-120V, 1-phase, to 1.5hp
SK700E
- Flexible high performance
- 380-460V, 3-phase, to 200hp

MINICASE RIGHT ANGLE WORM


- Foot, Flange or Shaft Mount
- Torque up to 3,540 lb-in
- Gear ratios 5:1 to 500:1

DRIVESYSTEMS

Table of Contents

Introduction ...................................................................................................................... 2
Company Information .................................................................................................. 2
Key Features .................................................................................................................. 4
Selection ........................................................................................................................ 9
General Warnings & Cautions .................................................................................... 11
Mounting Positions .................................................................................................... 14
Options ........................................................................................................................ 16
Lubrication .................................................................................................................. 26
Service Factoring ......................................................................................................... 44
Ratings ............................................................................................................................ 55
Gearmotor Selection .................................................................................................. 55
Reducer Selections & Combinations .......................................................................... 73
Dimensions .................................................................................................................. 55
Alternate Shaft Options ........................................................................................... 112
Motors........................................................................................................................... 117
Order Form ................................................................................................................ 118
Standard Design ....................................................................................................... 121
Options ...................................................................................................................... 126
Performance Data ..................................................................................................... 140
Brakes............................................................................................................................ 153
Contacts ........................................................................................................................ 175
Terms & Conditions of Sale.......................................................................................... 187

DRIVESYSTEMS

www.nord.com

INTRODUCTION

NORD Gear
Company Overview

Short, On-Time Delivery

Since 1965, NORD Gear has grown to global


proportions on the strength of product performance,
superior customer service, and intelligent solutions to
a never ending variety of industrial challenges.

As a NORD customer, you can rest assured that your


order will be delivered on time. Because NORD has
both decentralized assembly and manufacturing operations paired with a globally linked network, we
have the ability to offer our customers:

All mechanical and electrical components of a drive are


available from NORD Gear. Our products cover the full
range of drive equipment: helical in-line, Clincher
shaft-mount, helical-bevel, and helical-worm gearboxes, motors and AC drives from 1/6 hp to 250 hp,
with torques from 90 lb-in to 900,000 lb-in.
But NORD Gear does far more than manufacture
the worlds nest drive components. We provide our
customers with optimum drive congurations for their
specic purposes. NORD provides each and every one
of them with truly complete and efcient systems at
a price/quality ratio unmatched in todays fast-changing markets.

Fast, reliable responses


Greater product versatility
Shorter lead times
Timely shipping
Rapid delivery

Quality
Quality is assured at NORDs assembly and manufacturing facilities, based on ISO 9000 standards from
careful inspection of incoming materials to closely
monitored machining operations, including gear
cutting, turning, hardening & grinding as well as
nishing & assembly.

NORD Gear makes its wide range of products easily


available through a global network that provides all
customers with prompt delivery and expert support
services to consistently exceed customer expectations.
We are rmly committed to being totally responsive
to the ideas and specications of every customer, anywhere in the world.

High-Performance Motors & Brakemotors


NORD motors are designed to run cool for longer service life. Low rotor inertia and high starting torque
allow peak performance in the most difcult applications for inverter and vector duty per NEMA MG
1-2006 Section 31.4.4.2 voltage spikes. Our motors are
internationally accepted, conforming to North American NEMA MG 1 and international IEC electrical specications. High performance options include brakes,
encoders, and forced cooling fans.

NORD 911
Trouble? Just call 715-NORD-911 (in Canada, 905-7963606). Emergency service is available 24 hours a day,
7 days a week. Well answer your call, ship the parts,
or build a unit and have it shipped directly to you to
provide what you need, when you need it.

G1142 Subject to Change Without Notice

www.nord.com

Manufacturing

Modular Design

NORD continually invests in research, manufacturing and automation technology. This is to ensure the
highest possible quality at affordable prices. NORD
invests heavily in our North American facilities as
well as our factories around the world. Recent examples include expanding our Waunakee factory
and adding numerous new large gear unit assembly
cells. In our Glinde, Germany gear factory we added a
state-of-the-art multi-chamber vacuum carburization
system.

NORDs modular design philosophy provides you with


a competitive edge by allowing you to congure drive
systems to exactly t your applications.
More than 20,000,000 combinations of totally
unique gearmotors and speed reducers are possible
assembled in-line or right-angle, mounted by foot
or ange, featuring solid or hollow shafts with either
metric or inch shaft extensions to give you complete freedom to specify a drive solution thats perfect for you.
Benets

More output speeds


More mounting arrangements/Greater flexibility
Fewer gear stages/Lower cost
Metric and inch products

NORD engineers stand ready to assist you with your


custom applications. Most standard drives can be
modied to your purposes, and custom designs can be
developed for special applications.

Global Availability
From Shanghai to Charlotte, and all points in-between, NORD reaches customers around the world.
Deliveries, service, and product support are close at
hand, regardless of your location.

Worldwide Standards
NORD products are designed and manufactured based
on the latest North American and global standards.

Increased North American Presence


NORD covers North America with over 30 district
ofces and over 500 distributor branches. NORD
operates a manufacturing and assembly facility in
Waunakee, WI, Charlotte, NC, Corona, CA, Brampton, ON, and Monterrey, Mexico, resulting in an everincreasing capacity in North America and giving our
customers the shortest lead times in the industry.

Energy Efciency
Lowering your operating costs is one of our greatest goals! NORD research and development focuses
on energy efciency, with gearboxes, motors, and
frequency inverters designed for lower energy consumption. Our fully diverse line of in-line or rightangle units and motors has been developed to suit
your needs.

www.nord.com

G1142 Subject to Change Without Notice

INTRODUCTION

NORD Gear

INTRODUCTION

Key Features
Helical-bevel 92-Series Overview
NORD has developed a unique class of high performance right-angle speed reducers. The 92-series helical-bevel drives are available as gearmotors and
speed reducers with many mounting options. The
92-series bevel units provide high performance rightangle helical-bevel gear units at the cost effectiveness of a single worm system.
92 Series Bevel Units
SK 92072
SK 92172
SK 92372
SK 92672
SK 92772

UNICASE Design
NORD heavy-duty, one-piece housings are precisely
machined to meticulous standards. Internal reinforcements further increase strength and rigidity.
All bearings and seal seats are contained within the
casting, eliminating splits or bolt-on carriers that can
weaken the housing and allow oil leakage. Bores and
mounting faces are machined in one step, producing
extrememly precise tolerances thus ensuring accurate positioning of gear teeth, bearings and seals,
and longer life for all components.

92-Bevel Advantages
Compared to Single Worm Units
Premium efciency 97% gear efciency compared
to 40-90% of worm units (depending on the ratio)
Long gear life 92-Series gears are wear-free for
innite life worms are designed to need
replacement.
Many more ratios over 21 ratios per case size vs.
worms 9 ratios up to 60:1. May reduce the need
for additional components belts, chains, guards...
UNICASE quiet leak-free design The UNICASE
system eliminates splits or bolt-ons that may weaken
housings and aid oil leakage.
Runs cooler due to the high efciency worm gear
units tend to generate more heat and we believe
to have found a solution to that trend with our
high efciency ratings.
NORD motor advantages - inverter/vector duty,
many options: brakes, encoders, forced vent fans....

92-Bevel Advantages Compared To


Competitor Helical-Bevel Designs
The cost is up to 40% lower than traditional
helical-bevel designs
There are Lower gear ratios available that produce
higher output speeds

Concepts that Helped Acheive this


Innovative Product

92 Helical-Bevel
Premium efciency
Wear-free Gears
Leak-free Design
Quiet Operation

Optimal computerized design NORD has invested in


the latest design and manufacturing tools to ensure
maximum performance and price.

High Performance
Inverter Duty Motors
& Brakemotors
H-Series Energy Efcient
Standard Efcient

Reduced parts counts most helical-bevel reducers


are 3-stage: input helical, middle bevel stage, nal
stage helical. NORD has developed a two-stage helical-bevel reducer: rst stage helical and output stage
bevel. This reduces the number of parts required to
build a gear unit - 2 fewer gears, 2 fewer bearings, 1
less shaft, and fewer spacers and shims. This allows
NORD to achieve signicant cost reduction while
maintaining the ultra high quality of a helical-bevel
design.

Gear Efciency 97%


Gears up to AGMA
quality 13
UNICASE Cast Iron Design

G1142 Subject to Change Without Notice

www.nord.com

Standard NORD features

AUTOVENT

Modular Design

The AUTOVENT prevents bearing damage by


blocking entry of foreign material (water, dust,
corrosives, etc.) through the breather. A ball and
spring check valve opens at approximately 2 psi
during operation and closes tightly when the gearbox
cools, producing a slightly negative pressure that
ensures the valve seals tight. This keeps contaminants
out of the oil to maintain proper oil cleanliness
reducing contamination, foaming and oxidation.
The AUTOVENT is perfect for humid conditions,
washdown applications, and dusty environments.

All NORD products including the 92 Series


bevel units are modular in design and provide
extraordinary exibility. The 92 Series bevel units
provide great mounting versatility including:
Foot mount
Flange mount B5
Face ange mount B14
The 92 Series bevel unit may also be provided with a
number of different input components including:
Integral motor (Gearmotor)
NEMA C-face motor adapter
IEC B5 motor adapter
Solid input shaft
Custom motor adapter
(servo, hydraulic motors, and more)

Large Ratio Per Gear Stage


NORD gear cutting technology allows for the
production of gear sets with a higher maximum
ratio per stage than many other speed reducer
manufacturers. NORD commonly produces gear sets
with a maximum ratio of between 9:1 and 10:1 per
stage. This allows for double reduction gear units with
a maximum ratio between 72:1 and 100:1. Most speed
reducer manufacturers can only produce single-stage
reduction of between 5:1 and 6:1. This means a twostage reducer with a maximum reduction of about 25:1
to 35:1. NORD can often provide a two-stage reducer
when most companies must provide three-stage units.
The same situation applies to three, four and higher
gear stages. This allows NORD to provide superior
value and performance in many conditions.
Benets
Better value
Higher efciency
Quieter operation
Lower weight
Longer life

Benets
Cleaner gearbox oil
Extended lubrication life
Longer-lasting seals, gears, and bearings

High-Quality Gearing (Innite Life Design)


NORD continually invests in state-of-the-art gear
production equipment and in gear research. This
allows us to produce exceptionally high quality gears.
Benets

Designed and manufactured up to AGMA CLASS 13


Innite design life
Case-hardened steel
Exceptional hardness: 58 Rc minimum
High-speed gears are ground;
low speed gears are skive hobbed
275% momentary overload capacity
Low noise
Low maintenance

Factory Oil Filled


All 92 Series Bevel units are lled at the factory with the
proper quantity and type of lubrication. Oil ll before
shipping prevents damage from dry start-ups.
Benets
No need for lling on-site
Ensures proper oil grade and ll level

NORD High-Performance Motors & Options


NORD motors are designed to run cool for producing
longer service life. Low rotor inertia and high starting
torque allow peak performance in the most difcult
applications for inverter and vector duty per NEMA
MG 1-2006 Section 31.4.4.2 voltage spikes. Our
motors are internationally accepted, conforming to
North American NEMA MG 1 and international IEC
electrical specications. High performance options
include brakes, encoders, and forced cooling fans.

www.nord.com

G1142 Subject to Change Without Notice

INTRODUCTION

Key Features

INTRODUCTION

Premium
Efficiency
Comparison
Following is an example of the cost savings that might be
expected by selecting a NORD 92-series helical-bevel gearmotor
instead of a worm only design.

Premium Efficiency
NORDS research and development is focused on energy
efciency. The design of our
gearboxes, motors & AC vector drives will dramatically
reduce energy consumption.
The 92-series helical-bevel
gear unit was developed
with a gear efciency of
97%. Typical right angle
worm reducers range in
efciency from 40% to 90%,
depending on size, ratio and
output speed. NORD offers
motors of either standard
efciency or of the energy
efcient design to suit your
needs. Lowering our customers operating expenses
is one of our primary goals.
Benets:
Reduced energy
consumption
Lower operating costs

Competitor
Worm Gear
Model

NORD
Gearmotor

Energy Efcient

Energy Efcient

Standard Efcient

5.16 inch CD worm

SK92772-90LH/4

SK92772-90L/4

Motor power (hp)

Gear ratio

50

52.48

52.48

Output speed (rpm)

35

33

33

Output torque (lb-in)

3780

3823

3823

Gear efciency

70%

97%

97%

87.5%

84.0%

75.0%

4000

4000

4000

Motor efciency
Operating hours per year
Price of electricity (/kWh)

$511.54

$355.24

$397.87

Savings per year

N/A

$156.30

$113.68

Percent energy savings

N/A

31%

22%

Price of electricity (/kWh)

10

10

10

Energy cost per year

Energy cost per year

$1,023.09

$710.48

$795.73

Savings per year

N/A

$312.61

$227.35

Percent energy savings

N/A

31%

22%

Price of electricity (/kWh)

15

15

15

Energy cost per year

$1,534.63

$1,065.71

$1,193.60

Savings per year

N/A

$468.91

$341.03

Percent energy savings

N/A

31%

22%

Results
The NORD gearmotor can do the same job at 2 hp as the competitors worm reducer does with 3 hp. Both produce approximately the same amount of output torque. This is due to the
higher NORD gear efciency. The NORD Energy Efcient gearmotor also produces a 31% reduction in consumed electricity. This
produces an annual cost savings of $312.61 per year at 10 cents
per kilowatt-hour energy cost. The savings are even greater at
higher energy costs.

G1142 Subject to Change Without Notice

www.nord.com

Gear Unit

SK

Shaft/Mounting

Reducer Options

Gear Unit

:1
see pages 58 - 71
OR
Output Speed

rpm

H - Hollow Shaft Cover 18


D - Torque Arm 19
LL - Long Term Storage 21
NEMA
Adapter
N56C
N140TC
N180TC
N210TC
N250TC

see page 15

SM5 - Stainless Steel Shaft 19


SWA - Special Hollow Shaft 19
SS - Special Shrink Disc 19

Integral Motors

Paint

M5

M4

M3

B5 Flange Side
(if required)

B5 Flange Diameter
(if required)

Lubricant

Standard
Synthetic
Food Grade
Other _______

Torque Arm Side


Shrink Disc Side
& Location (if required)
(if required)

Side A

Side B
Location
see page 15

see page 15

Side A

Side B

H66 Side
(if required)

H66 Side A

H66 Side B

see page 15

see page 15

TB2

TB1

Terminal Box Pos.

TB1

TB2

TB3

TB4

TB3

www.nord.com

Other Speeds Available

Standard Stainless Steel Paint


NSD+ (gray)
NSD+W (white)
NSD-X3 (gray)
NSD-X3W (white)
Casting Primed
Special _______

M2

Gearmotor Only Details


Voltage & Frequency

230/460V-60Hz (460V only 40 hp)

575V-60Hz

208V-60Hz

400V-50Hz

115/230V-60Hz, 1 ph.

Other ___________

Integral Energy
Efcent Motors
80LH/4 - 1hp
90SH/4 - 1.5hp
90LH/4 - 2hp
100LH/4 - 3hp
112MH/4 - 5hp
132SH/4 - 7.5hp
132MH/4 - 10hp

63S/4 - 0.16hp
63L/4 - 0.25hp
71S/4 - 0.33hp
71L/4 - 0.50hp
80S/4 - 0.75hp
80L/4 - 1hp
90S/4 - 1.5hp
90L/4 - 2hp
100L/4 - 3hp
100LA/4 - 5hp
112M/4 - 5.4hp
132S/4 - 7.5hp
132M/4 - 10hp
Other Speeds Available

Flange Side A

Flange Side B

Flange Side A&B


see pages 113 - 114

Vl - Flouro-rubber Seals 20
OSG - Oil Sight Glass 20
MDP - Magnetic Drain Plug 21
ADP - Additional Drain Plug 21

M1

M6

see pages 58 - 71

Shaft Side A

Shaft Side B

Shaft Side A&B

PR - Flange Pilot Removal 17

IEC
Adapter
IEC 63
IEC 71
IEC 80
IEC 90
IEC 100
IEC 112
IEC 132
IEC160

Mounting Position
M1
M2
M3
M4
M5
M6
Special _______

Hollow Shaft
Solid Shaft Side
Diameter (if required)
(if required)

B - Fixing Element Kit 19

Product Specications
Ratio

see page 126

Reducer Options

Input
Shaft
W

see page 23

AFSH - Hollow Shaft/B5 Flange/Shrink Disc


AZSH - Hollow Shaft/B14 Flange/Shrink Disc

Motor Options

Shaft/Mounting
AX - Hollow Shaft/Foot Mount
AF - Hollow Shaft/B5 Flange
AZ - Hollow Shaft/B14 Flange

- Solid Shaft/Foot Mount


VF - Solid Shaft/B5 Flange
VZ - Solid Shaft/B14 Flange
VFL - Double Solid Shaft /B5 Flange
LX - Double Solid Shaft/Foot
LXZ - Double Solid Shaft/Foot/ B14 Flange

92072
92172
92372
92672
92772

Motor/Input

TB4

Mtg. Pos. M1 Shown


G1142 Subject to Change Without Notice

Conduit Entry Loc.

CE I
CE IV

CE II

CE III

CE IV
Brakemotor

CE III*

CE II

CE I*

Mtg. Pos. M1 Shown

INTRODUCTION

92 Series Bevel
Ordering Guide

Frame

Size

Poles

63
71
80
90
100
112
132

S
SH
M
MH
MX
L
LA
LH
LX

4
2
6
4-2
8-2
8-4
12-2
Other

Motor Options

Brake Size

Brake Options

SK
Electrical Motor Options
H - Energy Efcient Motor
TW - Thermostat
TF - Thermistor
SH - Space Heater (select voltage)

110 Volt
230 Volt 460 Volt
ISO H - Class H insulation
WU - High Resistance Rotor
4-2 - 2-Speed, 4/2 Pole, 1800/3600rpm
8-2 - 2-Speed, 8/2 Pole, 900/3600rpm
ECR - Single Phase Motor

BRE 5
BRE 10
BRE 20
BRE 40
BRE 60
BRE 100
BRE 150

Environmental Options

NSD+ - Nord Severe Duty Paint


NSDx3 - Nord Extreme Duty Paint
RD - Canopy Drip Cover
RDD - Double Fan Cover
KB - Condensation Drain Holes (plugged)
KBO - Condensation Drain Holes (open)
IP66 - IP66 Enclosure Protection
KKV - Terminal Box Sealed with Resin
AICM - Additional Insulation
EP - Epoxy Dipped Windings

Unpainted Aluminum Alloy

Stainless Steel Paint

NSD+ (gray)

NSD+W (white)

NSD-X3 (gray)

NSD-X3W (white)

Special _______

Rectier Selection

Frequency Inverter Related Options


F - Blower Fan (200-575V 1 & 3 Phase)
FC - Blower Cooling Fan (115V, 1 Phase)
IG__ - Incremental Encoder
IG__P - Incremental Encoder with Plug
AG - Absolute Encoder
Additional Motor Options
OL - Totally Enclosed Non-Ventilated (TENV)
OL/H - (TENV) Without Fan Cover
WE - Second Shaft Extension (Fan Side)
HR - Hand Wheel
Z - High Inertia Cast Iron Fan
RLS - Motor Backstop (rotation viewing fan)

Clockwise
Counter-Clockwise
EKK - Small Terminal Box (not UL approved)
MS - Quick Power Plug Connector

Brake Supply Voltage

Braking Method

24 VDC

115 VAC

200 VAC

230 VAC

400 VAC

460 VAC

500 VAC

575 VAC

Other ____________

Method 10

Method 15

Method 20

Method 25

Method 30

Method 35

Method 40

Method 45

Method 50

Method 55

Hand Release Position


HL 2

HL 3

HL1

HL2

HL3

HL4

HL 1

Paint

HL - Hand Release Lever


FHL - Locking Hand Release Lever
HLH - Hand Release Lever with Hole
RG - Corrosion Protected Brake
SR - Dust and Corrosion Protected Brake
ADJ_____Nm - Adjust Brake Torque
BIP66 - IP66 Brake Enclosure
MIK - Micro-switch
BSH - Brake Heating/Bilar Coil
NRB1 - Quiet Brake Release
NRB2 - Quiet Brake Motor Operation
FBR - Brass Foil
DBR - Double Brake
G...P - High Performance Rectier
G...V - Sealed Rectier
IR - Current Sensing Relay

Rectier Wiring

Across the line (from motor terminal box)

Separate power source (frequency inverter, soft starter)

HL 4

Mounting

Voltage & Frequency

Terminal Box Pos.

Integral to gearbox

NEMA C-Face

IEC B5 Mount

230/460V-60Hz

575V-60Hz

208V-60Hz

400V-50Hz

115/230V, 60Hz-1-ph.

Other

TB1

TB2

TB3

TB4

Conduit Entry Loc.

TB3

TB2

TB1

INTRODUCTION

Motor
Order Form

CE I
CE II
CE III
CE IV

CE III*

CE II

CE IV

CE I*
TB4

Mtg. Pos. M1 Shown


G1142 Subject to Change Without Notice

* Brakemotor

Mtg. Pos. M1 Shown

www.nord.com

Gearbox Selection

3. Service Factor or Service Class

A number of factors are considered when selecting


a gear unit, including gearbox rating, service factor,
speed and speed variation, horsepower, thermal capacity, ratio, physical size, ambient conditions and
cost. Below are some guideline steps to help aid in
the gear unit selection.

In addition to power or torque, service factor must


also be considered. A service factor is essentially
the ratio of extra capacity in a gear unit compared
to the power or torque that is needed to run that
application. The goal of selecting a gear unit with
extra capacity (service factor) is to provide adequate
service life in operation.

1.
2.
3.
4.
5.
6.
7.

Determine the speed and/or gear ratio


Determine the required power or torque
Determine Service Factor
Select the basic gearbox type and input
Determine the required mounting position
Select options
Checks overhung load, thrust load, NEMA motor
weight, thermal considerations, and other
application considerations

1. Speed and Gear Ratio


The rst step in selecting a gear unit is determining the nal output speed or speeds you need. This
speed is normally described in revolutions per minute (rpm). This output speed or speeds is determined by the input speed to the gear unit divided
by its gear ratio. Their relationship is described by
the following formulas.
Input speed [rpm]
Output speed [rpm]

i (gear ratio) =

Output speed [rpm] =

Input speed [rpm]


i (gear ratio)

To specify a gear unit, you can identify either gear


ratio needed or the output speed (rpm) if the input
speed is known.
2. Power and Torque
The second step for selecting a gear unit is the required power or torque needed to power the load.
Torque in this catalog is normally expressed in
pound-inches [lb-in].
Power [hp] =

Torque [lb-in] x speed [rpm]

Torque [lb-in] =

63025
Power [hp] x 63025
speed [rpm]

For a proper selection you must ensure that


the motor or other prime mover can produce enough torque or power and that the
gear unit has adequate torque or power
capacity.
To specify a gear unit you can identify either torque or
power.

www.nord.com

One reason to apply a larger service factor is if a unit


operates more hours per day. If a unit runs 24 hours
per day it should normally have a higher service
factor than a unit that runs 8 hours per day if you
expect the same calendar life.
A second reason for applying a larger service factor
is to cope with a more difcult application. Even if
it takes the same power and speed to operate a rock
crusher as a fan, the rock crusher needs a stronger
gearbox (higher service factor) to give the same calendar operating life as the gear unit powering the
fan.
The real question is how to determine the proper
service factor for a gear unit in an application. Following are four possible methods.
Customer or User Specication
Many customers will have their own service factor
guidelines or specications.
AGMA Service Factoring
American Gear Manufacturers Association (AGMA)
publishes lists of recommended service factors for
different applications. These service factor recommendations have been determined form the experience of many gear manufactures and are in AGMA
standard 6010. See page 44 for additional detail.
AGMA Service Classes
American Gear Manufactures Association (AGMA) has
another method for selecting gear units service factors. AGMA standard 6009 lists many applications by a
service class (I, II, III) with class I being the simplest
applications and class III being the hardest. These
application service classes are associated with a
range of service factors by the following table.
AGMA Service Class
I
II
III

Service Factor
1.00 to 1.39
1.40 to 1.99
2.00 and above

In the gearmotors selection table each unit is also


classied by an AGMA service class. See page 44 for
additional detail.

G1142 Subject to Change Without Notice

INTRODUCTION

Selection
Information

INTRODUCTION

Selection
Information
NORD Mass Acceleration Service Factoring

6. Options

NORD often uses a calculation based system to properly assign a service factor. This system considers hours
of operation per day, the severity of the application
and the number of times the equipment is cycled. See
page 44 for additional detail.

NORD offers a number of mechanical, protective,


paint and lubrication options for gear reducers and
motors. Please see page 16 for gear unit options and
refer to the motor section for motor options.
7. Checks

4. Gearbox Type & Input

Overhung Load

92 Bevel gear drives are available in the following


mechanical congurations including:
Foot mount
Flange mount
Foot mount with ange
NORDs modular design allows for a number of different inputs to be added to NORD reducers including:
Integral motor
NEMA-C and IEC motor adapter
Solid input shaft
5. Mounting Position
The gearbox mounting position is an important and
often overlooked specication. The mounting position determines how much oil the gear reducer requires, in addition to determining the position of the
oil drain, oil ll and vent on the gear drive. NORD
offers six basic mounting positions. If your application requires a variation from the six basic mounting
positions, please contact NORD.

M6

M1
M2

R
An overhung or radial load exists when a force is applied at
right-angles to a shaft beyond the
shafts outermost bearing. Pulleys,
sheaves and sprockets will cause an
overhung load when used as a power take-off. The
amount of overhung load will vary, depending on the
type of power take-off used and where it is located
on the shaft.

Overhung load [FR] can be found in the gearmotor


rating tables and input shaft overhung load ratings
[FR1] can be found on pages 35 - 41. Overhung load
capacities should not exceed the values in the table to
ensure long bearing life.
To calculate overhung load see page 35.
Thrust Loads (Axial)
Loads that are directed towards or away from the gearbox along the axis of the shaft are called thrust or axial
loads. Output shaft thrust capacity [FA] can be found
in the gearmotor rating tables. Input shaft capacity
[FA1] can be found on pages 41. Thrust load capacities
should not exceed the values listed in the tables to ensure long bearing life. Contact NORD for combination
loads or a more exact examination of the application.

M5

NEMA C-face Motor Weight Limits


M4

M3

M6

M2

M1

M5

When mounting a motor to a NORD NEMA C-face


motor adapter it is important to consider the motors weight. Following is a table that includes
the maximum motor weight the NEMA adapter can support. If the motor exceeds the listed
weight it must be externally supported. When a
C-face mounted motor is externally supported care must
be taken to ensure that the support system does not
impose additional pre-loads on the NEMA motor
adapter.
NEMA Weights

M4

Motor FRAME

56C

143TC

145TC

182TC

66

88

110

130

184TC

210TC

175

220

M3

Max Weight [lb]


Motor FRAME
Max Weight [lb]

10

G1142 Subject to Change Without Notice

www.nord.com

GENERAL WARNINGS
& CAUTIONS
Applications with risk of personal injury should be
reviewed together with NORD. Examples of these
are hoist, lifts or other applications where people
may be at risk.
NEMA and IEC Adapters
NEMA/IEC adapter have additional shaft coupling
and additional bearing seats compared to integral
motors so there are higher no-load losses with NEMA
or IEC adapters. We recommend mounting the motor
directly, since it offers both technical and cost advantages.
NEMA and IEC adapters used in hoist, lifts and other
applications with danger of personal injury should be
reviewed together with NORD.
NEMA C-Face Adapter Capacity
The NEMA adapters are designed to handle the
torques produced by the standard NEMA power assignment at 4-pole (1800 rpm) motor speeds. If a
larger motor power is used than the power below,
NORD should be consulted. Also if a NEMA adapter
is being used for other than an AC induction motor
NORD should be consulted.
Adapter
56C
140TC
180TC
210TC

Max Power
[hp]
1
2
5
10

External Installation, Tropical Use


Gearboxes installed outside, in damp rooms, or used
in the tropics may require special seals and anti-corrosion options. Please contact NORD for application
assistance.

Special conditions
If special environmental or other conditions exist in
transit, storage or operation these need to be considered in the unit selection. Special conditions may
include (but are not limited to):
- Exposure to aggressive corrosive materials
(contaminated air, gasses, acids, bases, salts, etc.)
- Very high relative humidity
- Direct contact between the motor and liquid
- Material build-up on the gear unit or motor
(dirt, dust, sand, etc.)
- High atmospheric pressure
- Radiation
- Extreme temperatures, high, low or
large temperature changes
- High vibration, acceleration, shocks or impacts
- Other abnormal conditions
Gear Reducer Ratings
The permissible continuous power limit of gear reducers is limited by both the mechanical rating and
the thermal rating. The mechanical rating depends
upon the material strength of the gear reducers
gears, bearings, housing, shafts, etc. The mechanical
input power limit to the reducer is also a function of
the mechanical power rating divided by the relevant
reducer service factor.
The thermal rating or thermal limit depends upon the
amount heat generated within the reducer and is inuenced by a variety of factors including:
Churning or splashing losses in the lubricant which
depend upon reducer type, ratio, input style,
mounting position or oil ll-level, and the circumferential travel velocities of the gear wheels.
The actual speed and load conditions. These factors determine load-depedent losses in the gear
areas and frictional losses in the gear, bearing &
seal areas.
Ambient Conditions:
- Ambient Temperature.
- Amount of free air circulation around the drive.
- Possible near-by heat sources.
- Heat dissipation or the ability of the reducer to
transfer heat through the housing, shafts, and
the mating sub-structure or mounting surface.
Storage Before Installation
The gear units and motors should be stored in a dry area
before they are to be installed. Special measures are
required for longer storage. Please request long term
storage instructions from NORD Gear or see page 21.

www.nord.com

G1142 Subject to Change Without Notice

11

INTRODUCTION

General
Warnings & Cautions

INTRODUCTION

Thermal
Considerations
Observing the Reducers Thermal Limit

Maximum Oil Sump Temperature Limit

When to Contact NORD

To prevent reducer overheating, the reducers maximum oil sump temperature limit must not be exceeded for prolonged periods of operation (up to 3 hours
continuous operation, depending upon reducer size).

Through computer program analysis NORD can evaluate application conditions and the impact they have
on a reducers thermal capacity.
When applying 92 series bevel gear units of case size
SK 92672 & larger, consult NORD if any two or more
of the following conditions apply:

Gear ratio, itotal 48:1


Input speed, n1 > 1800
Vertical positioning (mounting position M2 or M4)
Input conguration: NEMA C-face, IEC, servo adapter
or solid-shaft input (Type-W)
An elevated ambient temperature 86 F (30 C)
Dangers of Reducer Overheating
The following problems may result when the reducers thermal capacity or maximum oil sump temperatures are exceeded:
Lubrication oxidation, breakdown & deterioration.
A decrease in lubrication viscosity & lm thickness.
Loss of critical bearing and gear clearances required
for proper lubrication.
Increased contact pressures and increased operating
temperatures in the critical load zones of the gearing
and bearings.
An increased possibility for metal-to-metal contact
and premature component wear.
A signicant reduction in the lubricants ability to
prevent scufng, pitting, and in extreme cases
galling or welding.

12

Oil Type

Maximum Oil Temperature Limit


NORD

Mineral

AGMA 9005-D94

80-85 C (176-185 F)

95 C (203 F)

105 C (220 F)

107 C (225 F)

Synthetic

IMPORTANT NOTE
Use caution when specifying gear reducers for high temperature service. If there is concern about exceeding the
allowable safe operating temperatures, please consult
NORD to discuss alternatives.

Measures to Expand the Application Range


There are a variety of measures that may be taken
in order to protect against thermal overload and
expand the application range of the gear reducer.
Common examples include the following:
Recommending a change in lubrication viscosity
and/or a specic synthetic lubricant type.
Applying high-temperature seals.
Increasing air ow around the gear unit.
Shielding or protecting the reducer from high heat
sources.
Considering an integral motor instead of the bolt-on
input assembly covers. In many cases the motor fan
will substantially increase air-ow around the gear
unit.

G1142 Subject to Change Without Notice

www.nord.com

Contact:

Company:

Telephone:

Email:

Fax:

Date:

Project Name:

Application:

Qty:

Type: SK

Gearbox Parameters
Unit

Gearmotor

Gearbox with Solid Input Shaft


Mounting Position

Motor Parameters

Gearbox with Motor Adapter


Lubricant

M1

M4

M2

M5

M3

M6

Special _______

Standard

Synthetic

Food Grade

Other _______

:1

[hp]

Voltage & Frequency

230/460V-60Hz

575V-60Hz

208V-60Hz

400V-50Hz

115/230V-60Hz, 1 ph.

Other __________

Enclosure

IP55 (Standard)

IP66
Insulation Class

F (Standard)

Duty

Flange

None

B14 (Z)

B5 (F) Outside Diameter


Ratio

Power

Thermal Protection

None

Thermostat

Thermistor
cycles/hour

S-1 Continuous Operation

Periodic/Short Time Operation


[mm]

Cycles Per Hour

or Output Speed
[lb-in] or Power

[hp]

Minimum Service Factor [fb]

[lb]

Conduit Entry Location

CE I
CE III* CE II

CE II
CE IV

CE III

CE IV
Brakemotor
CE I*

TB3

Terminal Box Position


TB2

TB1

TB2

TB3

TB4
TB1

Output Torque

[rpm]

TB4

Radial Load at Output Shaft [FQ]

[lb]

Axial Load at Output Shaft [FA]

Brake Parameters
Brake

No Brake (cont. to next section)

Holding Brake/Emergency Brake

Working Brake

[lb]

Distance from Shaft Shoulder [x]

[in]

Brake AC Supply
Minimum Required Bearing Lifetime [Lh10]

[hours]

Brake Torque

Brake Supply

Power from motor term. block

Separate Power Source

[Volts]
[Nm]

Bearing Type

Standard

VL - Heavy Duty

AL - Axial/Thrust

Brake Release

Standard

Fast

Environmental Parameters

Frequency Inverter Parameters


Frequency Inverter

No Frequency Inverter

Customer Supplied Inverter

NORD Panel Mounted Frequency Inverter

NORD Motor Mounted Frequency Inverter

Ambient Temperature Range


Location of Unit

Indoor

Outdoor

Severe Environment

F to

Paint

No Paint

Stainless Steel Paint

NSD+ (gray)

NSD+W (white)

NSD-X3 (gray)

NSD-X3W (white)

Casting Primed

Special _______

Line Voltage:

Brake Stopping

Standard

Fast

Very Fast

[Volts]

Operating Frequency Range:


How is the Inverter Controlled?

PC

Operator Control

Other

Frequency
[Hz] to
Bus System?

None

Probus

CANBus

AS Interface

[Hz]
[Hz]

InterBus

CANopen

RS232

Are You Using an Encoder?

No

Position Feedback

Yes

Speed Control

www.nord.com

G1142 Subject to Change Without Notice

13

INTRODUCTION

Selection
Inquiry

INTRODUCTION

Mounting
Positions
Mounting Positions
The reducer mounting position determines the approximate oil ll level and the appropriate vent location. In some cases the mounting position may dictate possible variation in nal reducer assembly. If
considering any mounting positions that are not shown as catalog-standard options, it is critical that the
customer consult with NORD prior to ordering.
New Mounting Position System
NORD is in the processes of incorporating a new mounting position systems. Historically the NORD mounting
position system was based on international motor standards. NORD is changing in an effort to simplify the
system. The new system is based on the six sides of a cube. Below is a cross reference between the old and
new mounting position codes.
Mounting Position Cross Reference Table
New

M1

M2

M3

M4

M5

M6

Old

B3, B5

V3, V6

B8, B5I

V1, V5

B5II, B6

B7, B5III

92 Series Bevel

M6

M6

M2

M1

M1
M2

M5

M5

M4

M4

M3

14

M3

G1142 Subject to Change Without Notice

www.nord.com

Mounting Configuration
NORD provides gearmotors, speed reducers and motors that can be congured very differently to suit customer needs.
It is benecial while ordering that the drive be specied exactly the way you want it delivered.
Mounting Positions
Basic mounting
M1

M2

M3

Right-angle with solid shaft

M4

M5

Right-angle with shrink disc

B Side

Shaft Side A

Shrink Disc Side A

B Side

Shaft Side B

Shrink Disc Side B

Shaft Side A+B

A Side

Right-angle flange mount units


B Side

A Side

Right-angle with hollow shaft cover


Flange Side A

B Side

Hollow Shaft Cover Side A

Flange Side B
A Side

M6

Hollow Shaft Cover Side B

Flange Side A+B

Right-angle with torque arm

A Side

Brake motor with hand release lever


Hand Release
Lever Position 2

Torque Arm Side A

B Side

Torque Arm Side B

Hand Release Lever Pos. 1

Hand Release
Lever Position 1

A Side

Hand Release Lever Pos. 2


Hand Release
Lever Position 3

Hand Release Lever Pos. 3


Hand Release Lever Pos. 4

Shaft mount torque arm orientation


Hand Release
Lever Position 4

Conduit entry location


Orientation
92 - Bevel

90 - 315, Every 45

90 - Bevel

45 - 270, Every 45

Helical-worm

45 - 270, Every 45

Helical-worm 02040

90, 180, 270, Every 90

Terminal box location


Terminal Box
Position 2

Terminal Box
Position 1

Conduit Entry - III

Conduit Entry - IV

Conduit Entry - II
Conduit Entry - I

Conduit Entry Location I

Conduit Entry Location III

Conduit Entry Location II

Conduit Entry Location IV


Denotes Brakemotor

Terminal Box
Position 3

Terminal Box
Position 4

Terminal Box Position 1


Terminal Box Position 2

www.nord.com

Terminal Box Position 3


Terminal Box Position 4

G1142 Subject to Change Without Notice

15

INTRODUCTION

Mounting
Positions

INTRODUCTION

Gear Unit
Options
92 Series Bevel Gearbox Options
Abbreviation

Description

Blank or X
A
ADP
AF
AZ
B
D
DR
F
FV
H
LL
LX
MDP
OSG
OV
PR
SH
SM5
SS
SWV
SWA
Blank or V
VI
VF
VZ
X
Z
none
none

Foot mount
Keyed Hollow Shaft
Additional drain plug
Keyed Hollow Shaft with B5 Flange
Keyed Hollow Shaft with B14 Flange
Fixing Element Kit
Torque Arm
Autovent
B5 ange
Filtered Vent
Hollow Shaft Cover
Long term storage
Foot Mount with Double Solid Shaft
Magnetic drain plug
Oil sight glass
Open vent
B5 ange pilot removal
Shrink Disc and Cover
Stainless steel output shaft
Special Shrink Disc
Special Solid Shaft
Special Hollow Shaft
Solid Shaft
(FKM) Fluoro-rubber seals
Shaft Mount with B5 Flange
Shaft Mount with B14 Flange
Foot Mount
B14 ange
Special Drain Plugs
Paint coatings

16

Page

G1142 Subject to Change Without Notice

17
18
21
18 (A) & 17 (F)
18 (A) & 17 (Z)
19
19
20
17
20
18
21
18
21
20
20
17
18
19
19
19
19
18
20
18 (V) & 17 (F)
18 (V) & 17 (Z)
17
17
21
22

www.nord.com

Mounting

B5 Flange Pilot Removal (PR)

NORD offers a number of different mounting


arrangements including:

B5 anges have a centering pilot machined onto


the ange. In cases where there is not a matching
counter bore or when the ange must sit ush to the
mounting surface then the centering pilot must be
removed. This pilotless ange is used to rmly secure
the speed reducer to the application.

Foot (X)
B5 ange (F)
B14 ange (Z)

Foot Mounted (Blank or X)


Foot or base mounting is the most common method of
reducer mounting. The speed reducer is secured in
place with bolts or studs to a mounting base.

In some cases the matching surface already has a


centering pilot and the use of a female pilot (counter
bored ange surface) is recommended. Counter rotating drives are an example of where a female pilot
is frequently used.

B14 Flange (Z)


The B14 ange consists of threaded holes and a centering pilot machined into the reducer housing. It is commonly used to secure the reducer to the application,
machine base or to mount one of many bolt on components such as a B5 ange, or shaft cover. The B14
ange uses standard metric dimensions and allows a
compact method of securing the reducer.

B5 Flange (F)
A B5 ange provides a simple, large diameter mounting ange with clearance holes and a centering pilot
to rmly secure the speed reducer to the application.
The B5 ange utilizes standard metric dimensions
and is available for all NORD reducers. 92 Series bevel
reducers offer a number of B5 ange diameters.

www.nord.com

G1142 Subject to Change Without Notice

17

INTRODUCTION

Gear Unit
Options

INTRODUCTION

Gear Unit
Options
Shaft Options
Solid Shaft (Blank or V)

Shrink Disc & Cover (SH)

NORDs standard keyed solid shafts include a centered


threaded hole. Shafts are available in inch or metric
versions. The standard shaft materials are AISI1045
high carbon steel, AISI 4140 or an equivalent.

The shrink disc relies on the proven wedge principle


to create a keyless, mechanical interference t by
converting locking screw tension into radial contact
pressure on shaft and hub in effect shrinking it on
to the customer shaft. Shrink discs result in a zero
backlash mechanical interference t that can accommodate high torque unlike other mounting
technologies and will never wear or pound out, even
for high cycle uctuating and reversing loads.
The shrink disc cover is required with all shrink disc
units and provides protection from the rotating
shrink disc.
Other shrink disc advantages include:

Keyed Hollow Shaft (A)


NORDs standard keyed hollow shafts are made from
AISI 1045 high carbon steel. They feature standard
keyway dimensions and are available both inch and
metric designs. Many NORD reducers offer a variety
of hollow shaft diameters.

Elimination of fretting corrosion associated with


key connections.
Generous clearance for easy mounting & dismounting.
Allow for larger bores sizes compared to keyed
hollow shafts.

Hollow Shaft Cover (H)


Double Solid Shaft (L)
The standard solid shaft end is projected out both
sides of the speed reducer. This option is commonly
used to transfer torque out of both sides of the reducer or to mount a speed-monitoring device such as
an encoder on one of the shaft ends.

18

An optional cover can be used to guard from rotating hollow output shafts. It also protects the output
shaft seals against dust and dirt particles and in some
cases can be sealed against moisture and dust.

G1142 Subject to Change Without Notice

www.nord.com

Special Shafts & Shaft Materials


Stainless Steel Output Shaft (SM5)
Output shafts made from stainless steel are available
and are frequently used in food, pharmaceutical, and
washdown applications. In some cases stainless steel
solid input shafts may also be provided.

Special Solid Shaft (SWV)


Special solid shaft diameters and lengths may be provided for a nominal price adder. Special features are
also available including keyless shafts, cross drilled
shafts or special threaded taps. Different shaft materials are also available. NORD has in-house drafting,
design and machining departments so we may provide special requirements in short lead times. Specify
your shaft requirements and NORD will verify the
designs feasibility.

Fixing Element Kit (B)


(shaft shoulder xed and snap ring xed)
Due to the slight oscillations inherent in any rotating shaft, NORD offers an optional xing element
kit. This is a method to prevent the reducer from
walking out of position. The kit includes all necessary parts to secure the shaft in the axial direction by
using a tapped hole in the end of the mating male
shaft.
There are two methods for securing the xing element kit. The rst involves pulling the customer supplied male shaft to the snap ring (type 1) and the
second method the customer supplied shaft is shouldered (type 2) and pulled against the hollow shaft
and not the snap ring.

Special Hollow Shaft (SWA)


Special hollow bore shafts may also be provided. Special hollow bore shafts can be provided with special diameters, multiple keyways, and even special extended
hollow shafts that are frequently used with counter
rotating drives. Different shaft materials are also available. Specify your shaft requirements and NORD will
verify the designs feasibility.

Special Shrink Disc (SS)


Special shrink discs shafts may be provided with yourspecied diameters based on the table found on page
115. Special shrink discs can be provided with special
diameters and even special extended hollow shafts
that are frequently used with counter rotating drives.
Different shaft materials are also available. Specify
your shaft requirements and NORD will verify the
designs feasibility.

Snap Ring Fixed (Type 1)

Shaft Shoulder Fixed (Type 2)

Torque Arm (D)


A torque arm is a compact, simple way to secure a
shaft mounted reducer. It is bolted onto the reducers
B14 ange. The tear drop shaped torque arm has a
rubber bushing located at the fastening hole-end to
act as a shock absorber to dampen out peak shock
loads.

Specify the torque arm location and


orientation when ordering
Torque arm location
Torque arm orientation
See Page 15 for details

www.nord.com

G1142 Subject to Change Without Notice

19

INTRODUCTION

Gear Unit
Options

INTRODUCTION

Gear Unit
Options
Other Options

Autovent (DR)

(FKM) Fluoro-rubber Seals (VI)

The Autovent prevents entry


of foreign material, such as water, dust, corrosives, etc and is
perfect for washdown and dusty
environments. The Autovent
is a ball and spring check valve
that opens at 2 psi during operation and closes tightly when the
gearbox cools. The Autovent is
standard on all vented NORD reducers some of the benets are
cleaner gearbox oil, extended
lubrication life and longer lasting seals, gears, and bearings.

The NORD standard oil seals are made of Nitrile or


rubber and are rated for temperatures up to 125C or
250F. If ambient or oil temperatures rise above this
level NORD recommends using ouro-rubber (also
called FKM) oil seals. FKM seals are rated from -30F
to 400F (-35C to 200C).

Oil Sight Glass (OSG)


The oil sight glass provides a visible oil level indication
on the reducer. The sight glass replaces the standard
steel ll plug and consists of a sealed clear porthole
centered in the middle of a brass plug. The sight glass
allows for quick oil level and color inspection.

Open Vent (OV)


An open vent may be optionally supplied on NORD
reducers. The open vent allows for air pressure differences between the inner space of the reducer and
the atmosphere. This open vent will be closed upon
delivery to prevent oil leakage. Before the reducer is
put in service the open vent should be activated by
removing the sealing plug.

Sealed vent

Activated vent

Filtered Vent (FV)


NORD offers a ltered vent, which allows gases to
permeate, but does not allow dust and debris to pass
through the vent.

20

G1142 Subject to Change Without Notice

www.nord.com

Magnetic Drain Plug (MDP)

Additional Drain Plug Hole (ADP)

Magnetic drain plugs attract and hold ferrous metal


particles that may circulate inside the reducers oil
sump. These potentially abrasive particles may cause
excessive wear in the reducer if they remain circulating. An increase of material collected by the magnetic plug may be a warning sign of future problems.
The magnetic plug is available for units SK 92672 and
larger.

NORD can add an additional drain hole to the reducer


housing for a small surcharge if required for special
oil plumbing needs.

Special Drain Plugs


NORD oil drain valves are offered
to make draining the oil from the
gearbox clean and easy. The drain
hose needs to be supplied by the
customer. The hose ttings are offered in either 90 or straight to accommodate the user.

Long Term Storage (LL)


Speed reducers are frequently put in storage prior to
installation for long periods of time & in some cases
exposed to the elements. NORDs long term storage
option protects the unit from moisture or corrosion
by coating all unpainted surfaces with a dry, transparent, durable waxy lm. Once installation is necessary this waxy lm can be easily removed with a commercial de-greaser or petroleum solvent. If possible
the store room should be vented and dry, with room
temps. between 32F and 104 F (0 C and 40 C).

A brass drain valve is threaded into


the existing oil drain port of the
gearbox. The spring valve is closed
using a rubber o-ring. When the hose
tting is threaded into the drain
valve, the spring valve is pushed
open and allows oil to drain. When the hose tting
is removed, the drain valve closes. A brass, threaded
cap is supplied to cover the drain valve when not in
use.

www.nord.com

G1142 Subject to Change Without Notice

21

INTRODUCTION

Gear Unit
Options

Gear Unit
Options
Paint Coatings
NORDs standard paint coating is a two component, aliphatic polyurethane finish contaning 316 stainless
steel material. This gray stainless steel paint has excellent appearance and outstanding physical properties. It is suitable for both indoor and outdoor applications.
Advantages of NORDs stainless steel two component polyurethane:
INTRODUCTION

Excellent adhesion to cast iron, aluminum, steel, and plastics


Excellent corrosion resistance
Excellent chemical resistance
Excellent gloss and color retention
Suitable for indoor and outdoor exposure
Nonporous and excellent abrasion resistance
USDA compliant

NORD also offers a variety of severe duty paint coatings that provide a high level of protection against
water and severe environments both indoors and outdoors. NSD+ (NORD Severe Duty) consists of a primer
undercoat and a stainless steel polyurethane topcoat. For the most demanding environments, NORD offers NSD-X3 (NORD Severe Duty triple coated) which consists of a primer undercoat, stainless steel polyurethane coating, and a clear topcoat. Paint coatings are also available in alternate colors as seen in the
table below.
Finish

Color

Coating

Use

Standard (stainless steel paint) Stainless steel silver (Gray)

1 x Stainless steel (316) top coat (polyurethane)

Indoor or outdoor
moderate environment

Alternate color

Black, Blue, Red, Orange

1 x Color top coat (polyurethane)

Indoor or outdoor
protected

NORD Severe Duty +


NSD+

Stainless steel silver (Gray)

1 x Primer high solid alkyd system


1 x Stainless steel (316) top coat (polyurethane)

Indoor or outdoor
moderate environment

NORD Severe Duty +W


NSD+W

White

1 x Primer high solid alkyd system


1 x White top coat (polyurethane)

Indoor or outdoor
moderate environment

Alternate color NSD+

Black, Blue, Red, Orange

1 x Primer high solid alkyd system


1 x Color top coat (polyurethane)

Indoor or outdoor
moderate environment

NORD Severe Duty Extreme


Stainless steel silver (Gray)
NSD-X3

1 x Primer high solid alkyd system


1 x Stainless steel (316) (polyurethane)
1 x Clear top coat (polyurethane)

Indoor or outdoor more


severe environment

NORD Severe Duty Extreme


White
NSD-X3W

1 x Primer high solid alkyd system


1 x White (polyurethane)
1 x Clear top coat (polyurethane)

Indoor or outdoor more


severe environment

Alternate color NSD-X3

1 x Primer high solid alkyd system


1 x Color (polyurethane)
1 x Clear top coat (polyurethane)

Indoor or outdoor more


severe environment

Black, Blue, Red, Orange

Special colors and paints possible please contact NORD with your specific requirements.

22

G1142 Subject to Change Without Notice

www.nord.com

Input

NEMA C-Face Motor Adapter

NORDs modular design allows for many different


types of inputs to be added to gear reducers. All inputs are bolt on and include machined pilots to ensure simple and accurate assembly. NORD offers the
following different input types:

NEMA C-face motor adapters allow for easy installation and removal of industry standard C-face motors.
NEMA C-face motor adapters consist of a coupling
and an adapter housing that connects the motor
to the gear reducer. Gear units with NEMA C-face
adapters are commonly used where applications require specialized motors or the user wants to easily
nd a replacement motor if failure occurs. NORD
also offers high performance NEMA C-facemotors
and brakemotors, that can be factory installed to the
motor adapter.

Integral motor
Solid input shaft
NEMA C-face motor adapter
IEC B5 motor adapter
Custom mounting interface

Integral Motors
NORD provides integral motors that mount directly
to the gearbox. Integral motor mounting eliminates
the need for costly v-belts or sheaves and directly couples the motor to the reducer. This also results in a
dimensionally compact one-piece package.
NORD high performance integral motors are available
in many operational voltages, are inverter duty rated,
and offer many valuable options including energy efcient motors and power off brakes. For more information on integral motors, see the catalogs motor section
found on page 117.

Solid Input Shaft


Designed to mount couplings, sheaves or sprockets,
which transfer torque from the prime mover. The input shaft is made from ANSI 1045 or stronger material dimensioned with long keys according to ANSI
B17 standards. Bearings are sized to handle overhung
loads resulting from belt or sprocket inputs. See page
41 for more information on the capacity of each
input housing assembly. The maximum gearbox
input power rating is indicated in the speed reducer
performance tables.

NORD motor adapters deliver nearly 100% of the


torque generated by the motor and can be used from
-13F (-25C) to 212F (100C). Most motor adapters
have specially sealed bearings that are lubricated for
life.
The maximum input power of a gear unit with a
NEMA C-face adapter is generally limited by the
power rating of the standard NEMA C-face motor
size. The power limit is indicated in the ratings table
for a standard 4-pole 1750 rpm motor. In some cases
the gearbox limit (T2max) will be the limiting capacity.
Both the NEMA adapter limit and the gearbox torque
limit must be considered. If the speeds required exceed those included in the performance and speed
reduction tables please contact NORD.

IEC Motor Adapter


IEC motor adapters allow for easy installation and
removal of industry standard IEC motors according
to DIN 42677. The IEC adapter is very similar to the
NEMA C-face adapter in construction. The maximum
input power is generally limited by the IEC motor size.
For ratings and dimensions, please consult NORDS
metric catalogs that may be found online at
www.nord.com under the document section.

Vertical Motor Adapter Applications


Gear units with motors frame sizes 250TC (IEC160)
and larger, in a vertical up motor mounting position, NORD recommends using an integral gearmotor instead of a NEMA or IEC input adapter. If
your application requires this mounting position
and a NEMA or IEC input, please consult NORD. In
vertical down motor mounted applications it is recommended to shorten the maintenance interval.

www.nord.com

G1142 Subject to Change Without Notice

23

INTRODUCTION

Inputs

INTRODUCTION

Key Features
Couplings

Gear Couplings

Couplings are made with tough abrasion resistant


materials, which resist most chemicals and petroleum products. They are electrically isolated (prevent
metal to metal contact) and require no lubrication or
maintenance.

Gear couplings are used with 56C to 250TC adapters and provide a compact space saving design. Cface adapter input shafts have a machined male
spline that meshes with a molded nylon spline on
the coupling. This specially designed molded nylon sleeve that exhibits high torsional stiffness, resulting in minimum t-up backlash and reduced
internal frictional losses. Gear couplings lightweight
design yields low inertia and use blind assembly and
slip together components to make inspection easy
without disassembly.
NORD incorporates two styles of gear couplings, the
J and M styles. The J style is a one-piece coupling consisting of a nylon sleeve and metal hub that
is fused together. The M style is a two-piece coupling consisting of a separate nylon sleeve and metal
hub.

NEMA Motor Adapter Details


NEMA
NEMA Adapter
C-face Motor
Nomenclature
Frame Size

4 pole
Motor HP

56 C
56 C
143 TC
145 TC
145 TC
182 TC
184 TC
182 TC
184 TC
213 TC
215 TC
254 TC
256 TC

1.0
1.5
1.5
2
3
3
5
3
5
7.5
10
15
20

56C
56C
140TC
140TC
140TC
180TC
180TC
180TC
180TC
210TC
210TC
250TC
250TC

Max Motor
Weight
[lb]
66
66
88
110
110
130
175
130
175
220
220
450
450

Coupling
Description

Coupling Bore
(inches)

Maximum Coupling
Torque Capacity
(in-lb)

J14

0.625

177

J24

0.875

354

J28

1.125

797

3.3 min
6.6 min
6.6 min
4.9 min
3.3 min
7.4 min
4.4 min
13.1 min
7.9 min
5.2 min
4.0 min
3.3 min
2.5 min

1.125
M38

1416
1.375

M42

1.625

Safety Factor

1770

IEC Motor Adapter Details


IEC Motor B5
4 pole

IEC Adapter
Nomenclature

HP / kW

63 S/4
63 L/4
71 S/4
71 L/4
80 S/4
80 L/4
90 S/4
90 L/4
100 L/4
100 L/40
112 M/4
132 S/4
132 M/4
160 M/4
160 L/4

0.16 / 0.12
0.25 / 0.18
0.33 / 0.25
0.50 / 0.37
0.75 / 0.55
1.00 / 0.75
1.5 / 1.1
2.0 / 1.5
3.0 / 2.2
5.0 / 3.7
5.3 / 4.0
7.5 / 5.5
10 / 7.5
15 / 11
20 / 15

24

IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC

63
63
71
71
80
80
90
90
100
100
112
132
132
160
160

Max Weight
Limit
[lb]
56
56
67
67
89
89
111
111
133
133
177
221
221
441
441

Coupling
Description

Coupling Bore
(mm)

Maximum Coupling
Torque Capacity (Nm)

11
J14

20
14
19

J24

40
24

J28

28

90

M38

38

160

M42

42

200

G1142 Subject to Change Without Notice

Safety Factor

23.2 min
15.8 min
11.5 min
7.8 min
10.4 min
7.6 min
5.3 min
3.8 min
6.1 min
4.4 min
3.4 min
4.3 min
3.2 min
2.2 min
1.6 min

www.nord.com

Custom Mounting Interface


NORD
cally
and
dard

can provide custom input adapters typiconsisting of a special adapter plate


special coupling to mount non-standimensioned motors or other devices.

Motor Dimensional Drawing


Motor Weight
Motor performance specications, including torque,
horsepower and operating speed ranges.

When a custom input adapter is required, special attention needs to be given for each application to be sure the customer receives the
performance that is necessary.
The following
information is required:

NORD engineers will review the performance requirements and make a unit selection based on given parameters.

GEARBOX

NEMA/IEC
ADAPTER

ADAPTER PLATE FOR


MATING NEMA/IEC ADAPTER
TO HYDRAULIC/SERVO FLANGE

www.nord.com

G1142 Subject to Change Without Notice

SPECIAL
COUPLING

25

INTRODUCTION

Key Features

INTRODUCTION

Lubrication
The Importance of Proper Lubrication

When Synthetic Oils Are Used

Proper gearbox lubrication is essential in order to


reduce friction and component wear, and protect
against corrosion and rust. Gear lubricants reduce
heat and wear by inserting a load-sharing protective uid lm between mating parts and preventing direct metal to metal contact. Properly selected
lubricants will operate under various lm conditions,
improve heat transfer, optimize reducer efciency,
absorb shock loads, reduce noise, inhibit foaming,
and separate water readily.

Synthetic gear oils are suggested when mineral gear


oils have reached their performance limit or when
they no longer meet certain application requirements. NORD may recommend synthetic oil for any
one of the following conditions:

Design Considerations
Along with many other factors, the gear designer
must consider the gear load and speed conditions,
and the expected operating oil temperatures. These
factors help determine a generally suitable oil category, a desired additive package, preferred base-oil
type, and oil viscosity.
It is important that the consumer be aware of these
many design factors before making any changes in
the critical areas (oil category, base-oil type, viscosity,
etc.) One should consult their preferred lubrication
supplier or NORD Gear when questions arise.

Gear Oil Types, Categorized by Base Oil


Mineral Oil with an EP Additive
(DIN 51517, Type CLP)
High performance mineral gear oils are carefully engineered and manufactured to improve aging characteristics, minimize friction, offer good wear protection, provide corrosion and oxidation resistance,
minimize foam, and separate water. Mineral gear oils
are classied as API Group I or II oils, depending upon
viscosity.
The standard NORD mineral gear oil has an extreme
pressure (EP) additive ISO Viscosity Grade EP220
(AGMA 5 EP) and is generally acceptable for helical
gear units. Good quality mineral oil should have the
ability to operate at moderate sump temperatures (up
to 80-85 C) without losing viscosity or thickness. A
minimum viscosity index (VI) of 93 or higher is suggested. The oil must also have good lm strength to handle shock loads, high torque, and start-up conditions.
A minimum FZG Scufng Load Stage 12 is desirable.

Severe duty applications or when gears are exposed to


frequent starts and stops, high-load or shock.
For applications in low or high temperature service.
To extend oil service interval requirements.
To eliminate the necessity for seasonal oil changes.
To extend service life of factory-sealed or maintenancefree gear units.
To take advantage of performance benets: shear
resistance, low traction coefcient, reduced internal
friction, improved lubricity, reduced operating
temperatures, improved gear efciency, etc.

Performance Advantages of Synthetic Oil


Compared to mineral oils, synthetic oils provide a
number of performance advantages including:
Ability to operate at higher temperatures without
losing viscosity or thickness, due to a much improved
viscosity index.
Improved low-temperature stability due to a lower
pour point
Increased oil change intervals due to superior
oxidative & wear resistance
Lower tendency to form residues and increased
resistance to foaming.
Other benets may include: very good shear
resistance, low traction coefcient, reduced internal
friction, improved lubricity, reduced operating
temperatures, improved gear efciency, extended
component life and wear protection.
When application conditions warrant the use of
synthetic oil, NORD may suggest a particular type of
synthetic oil, depending upon the gear unit type and
the application.

Advantages:
Most economical of all the gear oil types.
Generally offers good compatibility with shaft seals,
gaskets, paint nishes, etc.
Offers good corrosion and oxidation protection.
Effectively reduces internal friction and wear.

26

G1142 Subject to Change Without Notice

www.nord.com

Synthetic Hydrocarbon/Polyalphaolen
(SHC/PAO) Oil (DIN 51517, Type CLP-HC)

Polyalkylene Glycol or Polyglycol Synthetic Oil


(DIN 51517, Type CLP-PG)

Synthetic Hydrocarbons (SHC) or Polyalphaolen


(PAO) synthetic base oils offer good miscibility with
mineral base oils and are very readily available. SHC/
PAO oils are classied as API Group IV oils. The can
be formulated with or without anti-wear (AW) or
extreme pressure (EP) additives. They can also be
formulated for acceptance in food-grade applications.

Polyalkylene glycol or polyglycol (PAG or PG) synthetic gear oils are made readily available through
many lubrication suppliers. PG oils are classied as
API Group V gear oils. They can also be formulated
for acceptance in food-grade applications.

Advantages:
Higher viscosity index and therefore greater hightemperature stability than mineral oil.
Better low-temperature stability and lower pour point
than mineral type gear oils
High surface tension and lower tendency to foam
compared to mineral oil, and water-soluble polyglycol
gear oils.
Compatible (miscible) with mineral oil.
Better water seperability (demulsibility) than PG oils.

PG gear oils possess extremely low traction coefcients and a viscosity index higher than any of the
other synthetics (often greater than 220 VI), resulting
in excellent heat resistant, shear stability, and natural
anti-wear properties.
Typical PG gear oils are formulated with a 1:1 or higher ratio of ethylene oxide to propylene oxide (50:50
or 60:40 is common); this makes PG gear oils water
soluble, providing them with very good corrosion resistance even when water is present in concentrations
that are higher then what is normally allowed.
Advantages:
PG oils offer the highest viscosity index of any other
synthetic resulting in excellent heat resistant, shear
stability, and superior natural anti-wear properties
without requiring EP-additives.
PG gears oils minimize internal friction and often result
in improved gear efciency.
PG oils have signicantly higher lm strength than
mineral and SHC/PAO oils and out perform these oils at
higher operating oil temperatures (approaching 80C
or higher).

IMPORTANT NOTE
Polyglycol (PG) oils are not miscible with other oil types
and should never be mixed with mineral oil, hydrosynthesized synthetic or PAO synthetic oils.

www.nord.com

G1142 Subject to Change Without Notice

27

INTRODUCTION

Lubrication

INTRODUCTION

Lubrication
Food-Grade Lubricants

The Importance of Oil Viscosity

Food-grade lubricants should be manufactured in


compliance with FDA 212 CFR 178.3570 and should
either satisfy the former 1998 USDA Guidelines as an
H1 lubricant or currently qualify as a NSF-H1 lubricant. Please consult with lubrication manufacturers
for more information or visit www.nsf.org

Viscosity or the oils resistance to shear under load, is often considered the single most important property of
any gear oil.

H1 food grade oil can only contain additives which


appear on the FDA approved list for food safe compounds. H1 oils are generally absent of common zincbased AW additives, and sulfur-phosphorus based, EP
chemistries, commonly found in many industrial gear
oils.
Food manufacturers control risk and liability by following detailed guidelines outlined by the HACCP
(Hazard Analysis and Critical Control Point) program,
which includes food-grade H1 lubricants.
Food grade H1 lubricants may be formulated as highly rened mineral oils (white oils), SHC/PAO synthetic
oils or PG synthetic oils.
The highly rened nature of good-quality food-grade
white-oils provides good long-term oxidative stability
and in most cases adequate lubrication under highload (boundary) conditions. So long as food-grade
white oils meet the minimum anti-wear requirements
of the normally specied non-food grade oil, they are
often acceptable.
Both food-grade white oils and PAOs have an inherent purity and absence of polar compounds, making them better than the average mineral oil or even
PG oil in terms of demulsibility (water seperability).

NORD Gear Designers have selected the most appropriate ISO viscosity grade of oil, for each type or class
of gear reducer. Gear oil viscosity is selected by assuming typical ambient conditions, at rated speed and
load conditions.
Important Considerations:
The correct viscosity selection helps provide proper
lubrication and assures that a minimum lm thickness is
maintained between interacting surfaces.
The degree to which viscosity changes with temperature or the viscosity index, varies from oil to oil,
and depends upon the type of lubricant & additive
agents used.
Selecting too low of a viscosity can result in mixed
boundary (partial metal-to metal contact) or boundary lubrication (full metal-to-metal contact) conditions, increasing internal friction heat build-up and
wear.
Selecting too high of a viscosity results in increased
churning and squeezing losses in the load zone and
excessive heat (especially when peripheral gear speeds
are high); Ultimately, this causes the oil temperature to
rise and the viscosity to go down, decreasing the
effectiveness of the lubricant.

Compared to food-grade white-oils, food-grade synthetic PAO or PG oils typically provide:


Better wear and oxidation resistance.
Improved high-temperature characteristics.
Better cold-temperature behavior.

28

G1142 Subject to Change Without Notice

www.nord.com

Considering an Oil Viscosity Change

Maximum Oil Sump Temperature Limit

There are three primary reasons to consider a lubrication viscosity change as follows:

To prevent reducer overheating, the reducers maximum oil sump temperature limit must not be exceeded for prolonged periods of operation (up to 3 hours
continuous operation, depending upon reducer size).

1. Low temperature gear oils should be selected so


that the pour point is at least 9F (5C) lower than the
expected minimum ambient temperature. In extreme
cases, consider a lower ISO Viscosity rating and test
the critical performance of the gear box under cold
start-up.
2. High temperature applications may require
an increase in the lubricants viscosity to assure proper lubrication conditions in the critical load zones of the gear unit. NORD also recommends switching to synthetic oil if oil sump
temperatures exceed 176-185 F (80-85 C).
3. In cases of extreme load conditions, gear pairs
and antifriction bearings may be more susceptible to
scufng wear. In these operating conditions, it may
be benecial to consider an increased lubrication
viscosity and/or lubrication with improved antiwear
additive packages.

Oil Type

Maximum Oil Temperature Limit


NORD

Mineral

AGMA 9005-D94

80-85 C (176-185 F)

95 C (203 F)

105 C (220 F)

107 C (225 F)

Synthetic

IMPORTANT NOTE
Use caution when specifying gear reducers for high temperature service. If there is concern about exceeding the
allowable safe operating temperatures, please consult
NORD to discuss alternatives.

IMPORTANT NOTE
NORD recommends that the user consult with their
primary lubrication supplier when considering
changes in oil viscosity.

www.nord.com

G1142 Subject to Change Without Notice

29

INTRODUCTION

Lubrication

INTRODUCTION

Lubrication
Ventilation

Lubrication Replacement

Most gear reducers are equipped with a vent which


helps compensate for air pressure differences between the inner space of the gear unit and the atmosphere.

If the gear unit is lled with mineral oil, the lubricant should be replaced at least after every 10,000
operating hours or after every two years. If the gear
unit is lled with synthetic oil, the lubricant should be
replaced at least after every 20,000 operating hours
or after every four years. Often gear reducers are
exposed to extreme ambient conditions, hostile environments, wet conditions, or dirty and dusty operating areas. Especially in these situations, it is important to establish a condition-based oil service interval.

The spring-pressure vent (Autovent) is commonly


supplied and factory-installed. Normally open vents
may also be supplied as an option; normally-open
vents are closed upon delivery in order to prevent oil
leakage during transport. When normally open vents
are supplied, the sealing plugs must be removed prior
to commissioning the reducer.
Prior to reducer start-up, it is important to check the
maintenance manual to verify that the vent is properly located with respect to mounting position.

Mounting Position
The reducer mounting position determines the approximate oil ll-level and the appropriate vent location. In some cases mounting position may dictate
possible variation in nal reducer assembly.
If considering any mounting positions that are not
shown as catalog-standard options, it is critical that
the customer consult with NORD prior to ordering.

Oil Fill Quantities


Oil ll quantities shown in the catalog or maintenance
instructions are approximate amounts. The actual oil
volume varies depending upon the gear ratio. Prior
to commissioning the reducer, the oil-ll level should
be checked using the reducers oil-level plug. It may
be necessary to drain excess oil or add additional oil.
Unless otherwise specied, NORD supplies most all
gear units factory-lled with the standard lubrication
type per the specied mounting position.

30

The Importance of Routine Oil Analysis


Routine oil analysis, sound lubrication practices, and
good tracking of oil performance trends will help establish proper lubrication maintenance and changeout intervals. To maximize equipment reliability,
NORD Gear generally recommends a condition-based
lubrication maintenance program. One may take exceptions to this general recommendation on sealedfor-life or maintenance-free gear units or smaller and
less costly gear units. In these instances, the replacement cost of the gear unit is often small compared
to the costs associated with this type of oil analysis
program.
NORD suggests replacing the gear oil if oil analysis
indicates any of the following:
Viscosity has changed by approximately 10% or
more.
Debris particles (silicon, dust, dirt or sand) exceed
25 ppm.
Iron content exceeds 150-200 ppm.
Water content is greater than 0.05% (500 ppm).
The total acid number (TAN) tests indicate a
signicant level of oxidative break-down of the oil,
and a critical reduction in performance; If the TAN
number measured changes by more than 5% over
the new oil, then an oil change would be
recommended.

G1142 Subject to Change Without Notice

www.nord.com

Lubrication
Proper gearbox lubrication is essential in order to reduce friction, heat, and component wear. Lubricants reduce heat and wear by inserting a protective fluid boundary between mating parts and preventing direct
metal to metal contact. Lubricants also help prevent corrosion and oxidation, minimize foam, improve heat
transfer, optimize reducer efficiency, absorb shock loads and reduce noise.
Mounting position not only determines the proper fill-level but may also have some effect on final reducer
assembly. If considering any mounting positions that are not shown as catalog-standard options, it is critical
that the customer consult with NORD prior to ordering. Unless otherwise specified, NORD supplies all 92 Bevel
gear units factory-filled with the standard mineral lubrication type and the appropriate quantity.
Standard Oil Lubricants
Gear Unit Type

ISO Viscosity

Oil Type

Ambient Temperature Range

Manufacturer Brand/Type

Notes

VG220

MIN-EP

0 to 40C (32 to 104)

Mobilgear 600XP220

VG220

PAO

-35 to 60C (-31 to 140F)

Mobil SHC630

VG220

FG

-5 to 40C (23 to 104F)

Fuchs FM220

ISO Viscosity

Oil Type

Ambient Temperature Range

Manufacturer Brand/Type

Notes

VG460

PAO

-35 to 80C (-31 to 176F)

Mobil SHC 634

VG460

FG-PAO

-35 to 80C (-31 to 176F)

Mobil/Cibus SHC460

VG220

FG-PAO

-35 to 60C (-31 to 140F)

Mobil/Cibus SHC220

VG150

PAO

-35 to 25C (-31 to 77F)

Mobil SHC629

92 Bevel

Optional Oil Lubricants


Gear Unit Type

92 Bevel

Standard Bearing Grease Lubricants


Grease Type/Thickener

NLGI Grade

Ambient Temperature Range

Manufacturer Brand/Type

Notes

Standard (Li-Complex)

NLGI 2

-30 to 60C (-22 to 140F)

Mobil Grease XHP222

High Temp (Polyurea)

NLGI 2

-25 to 80C (-13 to 176F)

Mobil Polyrex EP 2

Food-Grade (AL-Complex)

NLGI 2

-25 to 40C (-13 to 104F)

Mobil Grease FM222

Stocked Lubricants
Standard Oil Fill

IMPORTANT NOTES
Food grade lubricants must be in compliance with FDA 212 CFR 178.3570 and qualify as a NSF-H1 lubricant. Please
consult with lubrication manufacturer for more information.
When making a lubrication change, check with the lubrication supplier to assure compatibility and to obtain
recommended cleaning or flushing procedures.
Do not to mix different oils with different additive packages or different base oil formulation types. Polyglycol(PG)
oils are not miscible with other oil types and should never be mixed with mineral oil.
Consult NORD if considering oils of ISO Viscosity VG100 or lower.
Oil Formulation Codes
MIN-EP

Mineral Oil with EP Additive

PAO

Synthetic Polyalphaolefin Oil

FG

Food-Grade Oil

FG-PAO

Food-Grade, Synthetic Polyalphaolefin Oil

www.nord.com

G1142 Subject to Change Without Notice

31

INTRODUCTION

Lubrication Types

INTRODUCTION

92 Series Bevel Foot Mount


Positions & Oil Fill Quantities
92 Helical-bevel foot mount lubrication
All NORD Gear reducers are shipped from the factory with
a pre-determined oil ll level in accordance to the specied reducer size and mounting position. For additional information, please refer to the Oil Plug & Vent Locations
documentation for your gear unit.

M6

M1
STOP

HARMFUL SITUATION

M2

STOP

M5

Actual oil volume can vary slightly depending upon the


gear case size, mounting and ratio. Prior to commissioning
the reducer, check the oil-ll level using the reducers oil
level plug and drain or add addition oil as needed.

M4

For mounting orientations other than shown please


consult NORD Gear. Reducer modications may be
required.

Type

M1

M2

M3

Liters
Liters
Liters
Quarts
Quarts
Quarts
Quarts
SK 92072
0.420
0.400
0.630
0.600
0.530
0.500
0.530
SK 92172
0.580
0.550
0.950
0.900
1.000
0.950
1.16
SK 92372
0.950
0.900
1.37
1.30
1.53
1.45
1.69
SK 92672
1.90
1.80
3.70
3.50
3.38
3.20
3.59
SK 92772
2.43
4.76
4.86
5.60
2.30
4.50
4.60
Oil Levels shown apply to base models and gear units ending in LX, AX, & VX.

32

M3

M4

M5
Liters
0.500
1.10
1.60
3.40
5.30

G1142 Subject to Change Without Notice

Quarts
0.420
0.790
1.27
2.75
4.33

M6
Liters
0.400
0.750
1.20
2.60
4.10

Quarts
0.420
0.660
1.27
2.75
4.33

Liters
0.400
0.620
1.20
2.60
4.10

www.nord.com

92 Helical-bevel ange/shaft mount lubrication


All NORD Gear reducers are shipped from the factory with
a pre-determined oil ll level in accordance to the specied reducer size and mounting position. For additional information, please refer to the Oil Plug & Vent Locations
documentation for your gear unit.

STOP

HARMFUL SITUATION

M6

M2

M1

STOP

M5

Actual oil volume can vary slightly depending upon the


gear case size, mounting and ratio. Prior to commissioning the reducer, check the oil-ll level using the reducers
oil level plug and drain or add addition oil as needed.

M4

For mounting orientations other than shown please


consult NORD Gear. Reducer modications may be
required.

Type

M1

M2

M3

Quarts
Liters
Quarts
Liters
Quarts
Liters
SK 92072
0.420
0.400
0.630
0.600
0.530
0.500
SK 92172
0.530
0.500
0.970
0.920
0.920
0.870
SK 92372
1.22
1.15
1.59
1.50
1.27
1.20
SK 92672
1.64
1.55
2.96
2.80
2.64
2.50
SK 92772
2.91
2.75
4.65
4.40
4.76
4.50
Oil Levels shown apply to gear units ending in AZ, AF, VZ, & VF.

www.nord.com

M3

M4
Quarts
0.530
1.11
1.80
3.49
5.81

G1142 Subject to Change Without Notice

M5
Liters
0.500
1.05
1.70
3.30
5.50

Quarts
0.420
0.790
1.22
2.54
3.70

M6
Liters
0.400
0.750
1.15
2.40
3.50

Quarts
0.420
0.690
1.22
2.54
3.70

Liters
0.400
0.650
1.15
2.40
3.50

33

INTRODUCTION

92 Series Bevel Flange Mount


Positions & Oil Fill Quantities

INTRODUCTION

92 Series Bevel
Oil Plug & Vent Locations
Oil plug locations
Prior to commissioning the reducer, check the oil-ll level using the reducers oil-level plug and drain or add additional oil
as needed. For mounting orientations other than shown please consult NORD Gear. New plug locations may be required.

Foot Mount

Shaft/Flange Mount

M1
H1/B5I

M1
B3

M6
H6/V3

M6
V6

SK 92072
SK 92172
SK 92372
SK 92672
SK 92772

M2
B6

M5
V5

M4
B3I

M4
H3/B5II

M3
B8

M5
H5/V1

M
H6/

M3
H2/B5III

= Vent

34

M2
H4/B5

SK 92072
SK 92172
SK 92372
SK 92672
SK 92772

= Oil Level

= Oil Drain

G1142 Subject to Change Without Notice

www.nord.com

Radial Overhung Load (OHL)

Axial Load or Thrust Load

Any radial force or side force applied to the reducer shaft


is a source of OHL and should be examined during the reducer selection process. An overhung load is radial a force
that pulls (or pushes) against the reducers output (or input)
shaft.

Loads that are directed towards or away from the gearbox,


along the axis of the shaft, are considered to be axial loads
and are more commonly called thrust loads. Thrust loads
can result from the following conditions:

OHL is produced by one or more of the following conditions:


Transferring power at a right angle to the reducers
shaft, through an externally mounted power transmission device, such as a belt pulley, chain sprocket, or gear.
By tensioning of the external belt or chain, which is
required to keep belts from slipping, or to assure proper
chain wrap around sprockets.
The hanging weight of a pulley, sprocket or gear, mounted
on the reducer shaft.

There is a hanging weight connected to the reducer


shaft. This is common in mixer applications.
While operating the equipment, a net axial force is
directed towards or away from the reducer, along the
shaft axis. This is common in many screw conveyor or
mixer applications.
FTHRUST = Applied axial thrust load condition at output [lb]
FTHRUST1 = Applied axial thrust load condition at input [lb]

FOHL = Applied overhung load condition at output shaft [lb]

Thrust Rating General Conditions

FOHL1 = Applied overhung load condition at input shaft [lb]

The published thrust ratings are based upon the following:

OHL Rating General Conditions

The thrust capacity shown represents the worst case, and


is independent of direction.
Application loads can not exceed the values shown in
the tables.
There is no applied overhung load on the shaft.

The catalog OHL ratings are based upon the following:


The applied OHL is at the midpoint of the shaft.
The worst-case direction of shaft rotation.
There are no axial or thrust load conditions applied to
the reducer shaft.
The above conditions apply whether or not one is evaluating the output shaft or input shaft OHL conditions.

Output Shaft OHL Rating


The maximum permissible output shaft OHL rating is found
in the gearmotor selection tables. Output shaft OHL ratings
apply to integral gearmotors, C-face reducers, and reducers
with solid input shaft.
This is done by identify the power of the gear units driving
motor or prime mover, and then using the selection tables
to match the output shaft OHL rating with the selected
gear unit type, power, ratio and output speed condition.
FR

= Output shaft OHL rating, at shaft center [lb]

Input Shaft OHL Rating


Input shaft (Type W) OHL ratings are given on page 37 and
are represented by unit type and input power.
FR1 = Input shaft OHL rating, at shaft center

Output Shaft and Input Shaft Thrust Rating


The output shaft thrust capacity can be found in the gearmotor selection tables, adjacent to the OHL ratings.
FA

= Output shaft thrust rating [lb]

The input shaft thrust capacity is given on page 40.


FA1 = Input shaft thrust rating [lb]

IMPORTANT NOTE
To validate the gear unit selection, assuming negligible
OHL, the applied thrust condition must be less than the
shaft thrust rating.

Combined OHL and Thrust Load Conditions


Published values for both overhung load and thrust capacity are based upon the presence of a single condition and
assume the other condition is absent from the application.
In many applications, it is feasible to have both overhung
load and thrust at the same time.
Please contact NORD for more exact examination of the application, when both OHL and thrust conditions exist at the
same time.

www.nord.com

G1142 Subject to Change Without Notice

35

INTRODUCTION

Engineering
OHL & Thrust

INTRODUCTION

Engineering
OHL & Thrust
1. Calculate the applied OHL at the designated shaft
The most common radial OHL forces are created by transferring power at a right angle to the reducers shaft, through an
externally mounted power transmission device, such as a belt pulley, chain sprocket, or spur gear.
Included in the overhung load formula is an additional factor that is called the power transmission component factor (fZ).
The (fZ) factor accounts for the extra radial force caused by proper tensioning of belts or chains or the additional forces
created by the action of meshing gears.
The following equations are used to calculate the OHL forces generated by a belt pulley, chain sprocket, or spur gear and
they also account for the extra radial force caused by proper tensioning of the transmission component. These equations
treat the hanging weight of the transmission component as being negligible.
Variable denitions
FOHL

= Calculated shaft overhung load at output

FOHL1

= Calculated shaft overhung load at input

T2 or T1

= Load Torque [lb-in]

n2 or n1

= Shaft speed [rpm]

P1

= Load power at input

= Gear reducer efciency [%]

dOHL

= Pitch diameter of power


transmission component [in]

fZ

= Power transmission component factor

Output shaft equations


(common equation)
(alternate equation)
Input shaft equations
(common equation)
(alternate equation)

Gear reducer efciency can generally be ignored


unless considering compounded gear units, helical
worm gear units or worm gear units.

fZ factor table
Transmission Component

Factor fz

Notes

Gear

1.00

17 teeth or less

Gear

1.15

18 teeth or more

Chain Sprocket

1.40

13 teeth or less

Chain Sprocket

1.20

13 to 20 teeth

Chain Sprocket

1.00

20 teeth or more

Timing Belt Pulley

1.50

V-Belt Pulley

1.70

Flat Belt Pulley

2.50

R
STOP

HARMFUL SITUATION

STOP

When gear units are ange mounted opposite shaft, their OHL capacity is greatly
reduced compared to the standard catalog ratings. Please consult NORD for
details on OHL ratings.

36

G1142 Subject to Change Without Notice

www.nord.com

2. Determine the permissible shaft OHL rating


Output shaft OHL rating
Whether considering an integral gearmotor, C-face reducer,
or reducer with solid input shaft, the maximum permissible
output shaft OHL rating is found in the gearmotor selection
tables. Establish the output shaft OHL rating as follows:
First, identify the power of the gear units driving
motor or prime mover.
Then, use the gearmotor selection tables to identify
the output shaft OHL rating, by selecting the
appropriate gear unit type, power, ratio and output
speed condition.
Next, identify the output shaft OHL rating.
FR

Output shaft OHL rating, at shaft center [lb]

Input shaft OHL rating


Input shaft (Type W) OHL ratings are given below and are
represented by unit type and input power.
FR1

Input shaft OHL rating at shaft center [lb]

Permissable Overhung Loads (FR1) at Input Shaft [Lbs]


Gearbox
Type

0.16

0.25

0.33

0.50

Input Power - P1 [HP]


0.75
1.0
1.5
2.0

SK 92072

124

122

119

113

106

98

83

SK 92172

124

122

119

113

106

98

SK 92372

191

185

176

169

162

SK 92672

479

743

466

461

SK 92772

518

495

473

466

3.0

5.0

7.5

10

68

83

68

158

136

97

95

52

448

434

407

414

389

362

230

225

495

450

439

428

410

394

338

293

At midpoint of input shaft with no axial load

www.nord.com

G1142 Subject to Change Without Notice

37

INTRODUCTION

Engineering
OHL & Thrust

Engineering
OHL & Thrust
3. OHL rating correction applied load is not at the shaft center or midpoint.

FOHL or FOHL1
Applied OHL
Condition

If the OHL force is not applied at the midpoint of the shaft, an overhung load rating correction
must be applied to the catalog listed OHL rating. This OHL load correction is evaluated in two steps.

x Applied OHL
Location

I. Verify the bearing OHL capacity (Formula I).


II. Verify the shaft OHL capacity (Formula II).
INTRODUCTION

Overhung Load Variables


= Output shaft OHL Rating, at shaft center [lb]
= Input shaft OHL Rating, at shaft center [lb]
= Standard Bearing Capacity Rating, with OHL
applied at output shaft location x [lb]
FRX1
= Input Shaft Bearing Capacity, with OHL
applied at Input shaft location x [lb]
FRXW = Output shaft OHL Rating, at applied load
location x with standard bearings [lb]
FRXW1 = Input shaft OHL Rating, applied at shaft
location x [lb]
x
= applied OHL location with respect to
shaft shoulder [in]
Refer to Calculation Table Below
FR
FR1
FRX

z
y
f
c

=
=
=
=

Formula I Verifying Bearing Capacity


Output shaft (Standard bearings)
Input shaft

Formula II Calculating the shaft OHL capacity


Output shaft (Standard bearings)

Factor from table [lb-in]


Internal Geometry Factor from table [in]
Internal Geometry Factor from table [in]
Internal Geometry Factor from table [lb-in]

Input shaft

Make certain to apply the proper table values for the


shaft (output or input) that is being evaluated.
Output Shaft OHL Rating Correction Factors (for applied loads not at shaft center)
Gearbox Type

T2max

[in]

[in]

[lb-in]

[in]

[in]

[in]

[lb-in]

SK 92072

3.74

4.53

531

0.0

0.750

1.50

797

SK 92172

4.37

5.16

443

0.0

0.750

1.50

1,062

SK 92372

5.04

6.02

708

0.0

1.000

2.13

2,036

SK 92672
SK 92772

5.35
6.02

6.54
7.32

1,062
1,416

0.0
0.0

1.000
1.375

2.75
3.00

3,363
5,841

Input Shaft OHL Rating Correction Factors (for applied loads not at shaft center)
Gearbox Type

[in]

[in]

[lb-in]

[in]

[in]

[in]

SK 92072 - W

2.30

3.09

239

0.0

0.500

1.50

SK 92172 - W

2.30

3.09

239

0.0

0.500

1.50

SK 92372 - W

2.30

3.09

239

0.0

0.625

1.50

SK 92672 - W
SK 92772 - W

2.34
2.72

3.13
3.70

283
965

0.0
0.0

0.750
0.875

1.50
2.00

IMPORTANT NOTE
Calculations should always be made in accordance with Formula I (bearing capacity) and Formula II (shaft
capacity). The corrected OHL rating (for loads not at the shaft midpoint) will always be the lower of the two limiting
values based upon direct application of Formula I or Formula II.

38

G1142 Subject to Change Without Notice

www.nord.com

Engineering
OHL & Thrust
4. Compare the applied OHL to the OHL rating
To validate the unit selection (assuming negligible thrust loading), the applied OHL condition must be less than the rated
OHL capacity as shown below.
Output Shaft

Input Shaft

FOHL < FR
FOHL < FRX

FOHL1 < FR1 (applied load at shaft center)


FOHL1 < FRX1 (applied load not at shaft center)
INTRODUCTION

(applied load at shaft center)


(applied load not at shaft center)

Variable definitions
FOHL

= Calculated shaft overhung load at output

FOHL1

= Calculated shaft overhung load at input

T2 or T1

= Load Torque [lb-in]

n2 or n1

= Shaft speed [rpm]

P1

= Load power at input

= Gear reducer efficiency [%]

dOHL

= Pitch diameter of power


transmission component [in]

fZ

= Power transmission component factor

Gear reducer efficiency can generally be ignored


unless considering compounded gear units, helical
worm gear units or worm gear units.

Output Shaft Comparisons

<
FOHL

or
FR

<
FOHL

FRX
(Step 3)

Input Shaft Comparisons

<
FOHL1

or
FR1

<
FOHL1

FRX1
(Step 3)

IMPORTANT NOTE
Please contact NORD for more exact examination of the application when both OHL and thrust conditions exist at the
same time.

www.nord.com

G1142 Subject to Change Without Notice

39

Engineering
OHL & Thrust
5. Evaluating Thrust Capacity
To validate the unit selection (assuming negligible thrust loading), the applied thrust condition must be less than the rated
thrust capacity as shown below.
Output Shaft

Input Shaft

FTHRUST < FA

FTHRUST1 < FA1

INTRODUCTION

The output shaft thrust capacity (FA ) can be found in the gearmotor selection tables, adjacent to the OHL ratings. The
input shaft thrust capacity (FA1) can be found in the table below.
Permissable Axial (Thrust) Loads (FA1) at Input Shaft [Lbs]
Gearbox
Type

0.16

0.25

0.33

0.50

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10

SK 92072

277

252

224

200

173

131

79

65

SK 92172

277

252

224

200

173

131

79

65

SK 92372

277

252

224

200

173

131

79

65

45

34

SK 92672

659

646

626

587

558

525

467

441

392

329

146

101

SK 92772

833

788

720

698

675

630

585

540

495

450

405

338

With no overhung load

Input Shaft Comparisons

Output Shaft Comparisons

<

<
FTHRUST
(Supplied By
Customer)

FTHRUST1
(Supplied By
Customer)

FA
(Gearmotor
Selection)

FA1
(Found in
Table)

IMPORTANT NOTE
Please contact NORD for more exact examination of the application when both OHL and thrust conditions exist at the
same time.

40

G1142 Subject to Change Without Notice

www.nord.com

Computer Program Analysis Capabilities


Upon request, NORD can calculate the bearing service life and check the shaft durability for a specic gear unit type and
ratio, if provided with the following:
Type
i
P1
n2
FOHL
FTHRUST
DIR

=
=
=
=
=
=
=

L10h

Complete gearmotor or reducer model or type


Gear ratio
Load power at input [Hp]
Operating reducer output speed [rpm]
Applied shaft overhung load [lb]
Applied thrust load condition [lb]
Applied thrust direction (towards or away)
from gear unit.
applied OHL location with respect to the
shaft shoulder [in]
Desired bearing service life L10h [hours]

When provided the proper information NORD Engineering can


provide detailed analysis using a proprietary calculation program.

www.nord.com

G1142 Subject to Change Without Notice

41

INTRODUCTION

Engineering
OHL & Thrust

INTRODUCTION

Reducer
Tolerances
Solid Shaft Diameter Tolerance
> 0.375
1.750

[in]
+0.0000 / -0.0005

All Keys and Keyways: Inch - ANSI B17

Solid Shaft Diameter Tolerance


> 10
18
> 18
30
> 30
50

[mm]
+0.012 / +0.001
+0.015 / +0.002
+0.018 / +0.002

All Keys and Keyways: Metric - DIN 6885, class m6

Solid Shaft Drill & Tap Shaft End - Threaded Holes


> 0.500
0.875
1/4-20 x 0.59
> 0.875
0.938
5/16-18 x 0.71
> 0.938
1.100
3/8-16 x 0.87
> 1.100
1.300
1/2-13 x 1.10
> 1.300
1.875
5/8-11 x 1.42

[in]

Solid Shaft Drill & Tap Shaft End - Threaded Holes


> 16
21
M6 x 16
> 21
24
M8 x 19
> 24
30
M10 x 22
> 30
38
M12 x 28

[mm]

Keyed Hollow Bore Tolerances


> 0.4375
1.6250

[in]

Keyed Hollow Bore Tolerances


> 18
30
> 30
50

[mm]

+0.0010 / -0.0000

+0.021 / -0.000
+0.025 / -0.000

Metric hollow bore tolerances per ISO286-2, Class H7

Suggested Solid Shaft Tolerances for Keyed Hollow Bore


[in]
Uniform Load
Shock Load
> 0.4375
0.8750
+0.0000 / -0.0005
+0.0000 / -0.0005
> 0.8750
4.5000
+0.0000 / -0.0010
+0.0000 / -0.0010

Suggested Solid Shaft Tolerances for Keyed Hollow Bore


[mm]
Uniform Load
Shock Load
> 18
30
+0.000 / -0.013
+0.015 / +0.002
> 30
50
+0.000 / -0.016
+0.018 / +0.002
Uniform load: Mating shaft diameter tolerance per ISO286-2, class h6
Shock load: Mating shaft diameter tolerance per ISO286-2, class k6

Customer Shaft Diameter Tolerance w/ Shrink Disk


[in]
Shaft Diameter
Shaft Tolerance
Bore Tolerance
0.4375
0.6875
+0.0000 / -0.0004
+0.0007 / -0.0000
0.7500
1.1250
+0.0000 / -0.0005
+0.0008 / -0.0000
1.1250
1.9375
+0.0000 / -0.0006
+0.0009 / -0.0000
Inch Shaft Tolerances per ISO286-2, Class h6
Inch hollow bore tolerances per ISO286-2, Class H7
Solid Shaft nish to be 125 micro inches (3.2mm) or smoother

Flange Pilot (AK or AK1) Tolerance


Flange Pilot Diameter
Pilot Tolerance
> 1.969
3.150
+0.0005 / -0.0003
> 3.150
4.724
+0.0005 / -0.0004
> 4.724
7.087
+0.0006 / -0.0004
> 7.087
9.055
+0.0000 / -0.0005

[in]
Fit Class
j6
j6
j6
h6

Customer Shaft Diameter Tolerance w/ Shrink Disk


[mm]
Shaft Diameter
Shaft Tolerance
Bore Tolerance
> 18
30
+0.000 / -0.013
+0.021 / -0.000
> 30
50
+0.000 / -0.016
+0.025 / -0.000
Metric Shaft Tolerances per ISO286-2, Class h6
Metric hollow bore tolerances per ISO286-2, Class H7
Solid Shaft nish to be 125 micro inches (3.2mm) or smoother

Flange Pilot (AK or AK1) Tolerance


Flange Pilot Diameter
Pilot Tolerance
> 80
120
+0.013 / -0.009
> 120
180
+0.014 / -0.011
> 180
230
+0.000 / -0.013

[mm]
Fit Class
j6
j6
h6

Metric Pilot Tolerances per ISO286-2

Inch Pilot Tolerances per ISO286-2

Casting Surfaces may differ slightly (approximately 0.125 inches or 3.2mm) from the specied nominal dimensions as a result of the manufacturing process

42

G1142 Subject to Change Without Notice

www.nord.com

Engineering Conversions
& Formulas
Metric Inch
Multiply
Gram [g]
Kilogram [kg]
Newton [N]
Newton meter [Nm]
Newton meter [Nm]
Inertia [kgm2]
Kilowatt [kW]
Meter [m]
Meter [m]
Meter [m]
Millimeter [mm]
Centimeter [cm]
Cubic Centimeter [cm3]
Liter [l]
Liter [l]

By
x 0.0353
x 2.205
x 0.2248
x 8.851
x 0.7375
x 23.75
x 1.341
x 39.4
x 3.281
x 1.094
x 0.0391
x 0.394
x 0.061
x 61.023
x 1.057

To Obtain
= oz
= lb
= lb
= lb-in
= lb-ft
= lb-ft2
= hp
= in
= ft
= yd
= in
= in
= in3
= in3
= qt

Multiply
Ounce [oz]
Pound [lb]
Ounce [oz]
Pound [lb]
Pound-Inch [lb-in]
Pound Feet [lb-ft]
Pound Feet Squared [lb-ft2]
Horsepower [hp]
Feet [ft]
Yard [yd]
Inch [in]
Inch [in]
Inch [in]
Cubic Inch [in3]
Cubic Inch [in3]

By
x 28.35
x 0.454
x 0.028
x 4.448
x 0.113
x 1.3558
x 0.0421
x 0.746
x 0.3048
x 0.9144
x 25.4
x 2.54
x 0.0254
x 16.39
x 0.016

To Obtain
=g
= kg
= kg
=N
= Nm
= Nm
= kgm2
= kW
= kW
=m
= mm
= cm
=m
= cm3
= liters

Liter [l]

x 0.2642

= gal

Gallon [gal]

x 3.785

= liters

Temperature

Linear Velocity

F
C

= 1.8 C + 32
= 0.5555 x (F - 32)

= K - 273.16

Miles per Hour [mph]


x 88
= ft/min [fpm]
Miles per Hour [mph]
x 1.4677 = ft/sec [fps]
Feet per Minute [fpm]
x 0.3048 = m/min
Feet per Minute [fpm]
x 0.00508 = m/sec
Meter per Minute [m/min] x 3.2808 = ft/min [fpm]

Power
hp

hp

hp(Lift)

hp(Slide) =

Meter per Second [m/sec] x 196.85 = ft/min [fpm]


Torque (lb-in) x rpm

63025
Torque (lb-ft) x rpm

5252
Wgt (lb) x fpm
33000 x Efficiency
Wgt (lb) x x fpm
33000 x Efficiency

Linear & Rotational Speed


fpm

rpm

INTRODUCTION

Inch Metric

0.2618 x Dia(in) x rpm


fpm x 3.820

www.nord.com

Dia(in)

Torque
T(lb-in)

T(lb-ft)

hp x 63025

rpm
hp x 5252
rpm

Electric Motor 3-phase


hp(3ph-motor) =

1.732 x V x I x PF x Efficiency

746

Metric M Threads
For metric M threads, it
is customary to omit the
thread pitch for course
threads. For example, if a
thread is called out as an
M8 with no pitch shown,
it is automatically a course
pitch thread.

G1142 Subject to Change Without Notice

Course threads and pitch


M6 x 1
M8 x 1.25
M10 x 1.5
M12 x 1.75
M16 x 2
M20 x 2.5
M24 x 3

43

Mass Acceleration Service Factor


The mass acceleration factor (maf) uses a ratio of the
load inertia to motor inertia. This method of service
factor calculation can be used for both gearmotors
and speed reducers and is valid for helical gear units.
Short-term and infrequent torque impulses signicantly inuence the load and selection of a gear unit.
The gear unit service factor, fB, takes this and other
affects on the gear unit into account.
The mass acceleration factor (maf) represents the relationship between external low-speed output side
and high-speed input side masses. The mass acceleration factor signicantly inuences the level of
torque impulses in the gear unit upon start-up and
braking procedures, and upon vibration. The external mass moments of inertia also include the
load, such as the material transported on conveyor belts. We ask you to consult with NORD if the
maf > 10, if there is a large play in transfer elements,
vibration in the system, uncertainty regarding the
load classification, or you are in doubt.
For applications with relatively high external mass
moments of inertia, maf > 2 (i.e. travel drives, slewing
gears, rotary tables, gear drives, agitators, and surface aerators), we recommend breaking torque that
does not exceed 1.2 times the rated motor torque. If
a higher breaking torque is to be used, this must be
considered when selecting the gear unit.

If 3.01 maf 10.00 use curve C (heavy shocks)


Heavy mixers, shears, presses, centrifuges, rolling
stands, heavy winches and lifts, grinding mills, stone
crushers, bucket elevators, punching machines, hammer mills, eccentric presses, folding machines, roller
tables, tumbling barrels, vibrators, shredders.
2. Determine the cycles/hour. A cycle is a start or hard
stop, where a hard stop decelerates the motion of
the system when a mechanical brake is activated.
3. Determine the run time in hours/day.
4. Using the chart; locate the cycles/hour on the
horizontal axis and move vertically up to intersect
curve A, B, or C based on the maf. From the
intersection point, move horizontally left to the
service factor fB, which is based on the run time in
hours/day.
* Run time hours/day

Service Factor

INTRODUCTION

Engineering NORD
Service Factor

1. Calculate mass acceleration factor:


J
maf = load x
Jmotor

1
reducer ratio

fB

Jload = External load inertia including all components


of the system outside of the reducer
Jmotor = Motor inertia.
For NORD motors see pages 140 - 146
If maf 0.25 use curve A (uniform operation)
Light conveyor screws, fans, assembly lines, light conveyor belts, small agitators, elevators, cleaning machines, lling machines, inspection machines, belt
conveyors.
If 0.25 maf 3.00 use curve B (moderate shocks)
Coilers, feed-mechanism drivers for woodworking
machines, dumbwaiters, balancing machines, thread
cutting machines, medium-sized agitators and mixers,
heavy conveyor belts, winches, sliding doors, manure
scrapers, packing machines, concrete mixers, overhead crane traveling mechanisms, mills, bending machines, gear pumps.

44

Cycles / Hour

EXAMPLE for gearmotor:


A smooth running conveyor operates 24 hours/day
with 500 cycles/hour. The calculated maf = 0.16, therefore use curve A for this type of application.
From the chart, nd 500 cycles/hour and follow the
axis vertically up until you intersect curve A. From
the intersection point, move horizontally left to nd
the service factor fB = 1.4 based on 24 hours/day operation. Consult the selection pages of the catalog
to nd a gearmotor with a service factor fB = 1.4 or
greater.

G1142 Subject to Change Without Notice

www.nord.com

AGMA Selection Method


Gearmotors
Before a gearmotor is selected, an application class
number must be determined. Since application classication represents the normal relationship between
gear design power rating and the maximum potential
transmitted power, it is suggested that the application class number be applied to the nameplate rating
of the electric motor. The application class numbers
are l, ll, and lll.
Their relationship to service factor is:
Class Numbers

fB

1.0 - 1.39

II

1.4 - 1.99

III

2.0

Application class numbers may be selected from the


table. Some operational characteristics that affect an
applications classication are:
Starting conditions: Starting conditions where peak
loads exceed 200 percent of rated load, applications
with frequent starts and stops and reversing applications require special analysis. Rated load is dened as
the unit rating with an application class number of I
(1.0 - 1.39 service factor).
Overloads: Loads in excess of the rated load are considered overloads. Overload can be of momentary
duration, periodic, quasi-steady state, or vibratory
in nature. The magnitude and the number of stress
cycles require special analysis to prevent low cycle
fatigue or yield stress failure. Applications with
high torque motors, motors for intermitent operation and applications where extreme repetitive
shock occurs or where high-energy loads must be
absorbed as when stalling require special
consideration.
Brake equipped applications: When a gear drive is
equipped with a brake that is used to decelerate
the motion of the system, select the drive based on
the brake rating or the equivalent power, which
ever is greater. If the brake is located on the output
shaft of the gear drive, special analysis is required.
Reliability and life requirement: Applications requiring a high degree of reliability or unusually
long life should be given careful consideration by
the user and NORD GEAR before assigning an application class number. High reliability and life should
be addressed by using an increased safety factor
agreed to between NORD and the purchaser.

www.nord.com

Synchronous motors, certain types of high torque induction motors and generator drives require special
analysis.
Synchronous motors have high transient torque
during starting and restarting after they trip out
momentarily.
Induction motors of special high slip design can
produce extremely high starting torque. High torque
loads are produced when the motor trips out for a
very short time and then the trip re-closes.
Generators have extremely high loads when they
are out of phase with the main system and when
there are across the line short circuits.
Adjustments to the gear drive selection may be
necessary when one or more of the following exist:
Extremes of temperature and environment.
Lubrication. Any lubricant not in accordance with
NORDs recommendations.
Misalignment and distortions due to inadequate
foundations.
Reversing applications.
High-risk applications involving human safety.
The purpose of this table is to provide a guide in the
selection and application of gear drives designed and
rated in accordance with AGMA Standard 6009.
The service factor table has been developed from the
experience of manufacturers and users of gear drives
for use in common applications and has been found
to be generally satisfactory for the listed industries
when gears are applied using AGMA standards. It is
recommended that the user and NORD Gear agree
upon class numbers for special applications when
variations of the table may be required.

G1142 Subject to Change Without Notice

45

INTRODUCTION

Engineering
AGMA Service Classes

INTRODUCTION

Engineering
AGMA Service Classes
Load Duration

Application
AGITATORS (mixers)
Pure Liquids
Liquids and Solids
Liquids Variable Density
BLOWERS
Centrifugal
Lobe
Vane
BREWING AND DISTILLING
BottIing Machinery
Brew KettIes Continuous Duty
Cookers Continuous Duty
Mash Tubs Continuous Duty
ScaIe Hopper Frequent Starts
CAN FILLING MACHINES
CAR DUMPERS
CAR PULLERS
CLARIFIERS
CLASSIFIERS
CLAY WORKING MACHINERY
Brick Press
Briquette Machine
Pug MiII
COMPACTORS
COMPRESSORS
CentrifugaI
Lobe
Reciprocating, MuIti-CyIinder
Reciprocating, SingIe-CyIinder
CONVEYORS GENERAL PURPOSE
IncIudes Apron, AssembIe, BeIt,
Bucket, Chain, FIight, Oven & Screw
UniformIy Ioaded or Fed
Heavy Duty Not UniformIy Fed
Severe Duty Reciprocating or Shaker
CRANES
Main Hoist
Medium Duty
Heavy Duty
Reversing
Skip Hoist
TroIIey Drive
Bridge Drive
CRUSHER
Stone or Ore
DREDGES
CabIe ReeIs
Conveyors
Cutter Head Dives
Pumps
Screen Drives
Stackers
Winches

46

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

I
I
I

I
II
II

II
II
II

I
I
I

I
II
II

II
II
II

I
II
II
II
II
I
II
I
I
I

I
II
II
II
II
I
III
II
I
II

II
II
II
II
II
II
III
II
II
II

II
II
I
III

III
III
II
III

III
III
II
III

I
I
II
III

I
II
II
III

II
II
III
III

I
I
II

I
II
III

II
II
III

II
III
II
II
II
II

II
III
II
II
II
II

II
III
II
II
II
II

III

III

III

II
II
III
III
III
II
II

II
II
III
III
III
II
II

II
II
III
III
III
II
II

Load Duration

Application
ELEVATORS
Bucket
CentrifugaI Discharge
EscaIators
Freight
Gravity Discharge
EXTRUDERS
GeneraI
PIastics
VariabIe Speed Drive
Fixed Speed Drive
Rubber
Continuous Screw Operation
Intermittent Screw Operation
FANS
CentrifugaI
CooIing Towers
Forced Draft
Induced Draft
IndustriaI & Mine
FEEDERS
Apron
BeIt
Disc
Reciprocating
Screw
FOOD INDUSTRY
CereaI Cooker
Dough Mixer
Meat Grinders
Slicers
GENERATORS AND EXCITERS
HAMMER MILLS
HOISTS
Heavy Duty
Medium Duty
Skip Hoist
LAUNDRY TUMBLERS
LAUNDRY WASHERS

G1142 Subject to Change Without Notice

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

I
I
I
I
I

II
I
I
II
I

II
II
II
II
II

II

II

II

III
III

III
III

III
III

III
III

III
III

III
III

I
III
II
II
II

I
III
II
II
II

II
III
II
II
II

I
I
I
II
I

II
II
I
III
II

II
II
II
III
II

I
II
II
I
II
III

I
II
II
II
II
III

II
II
II
II
II
III

III
II
II
II
II

III
II
II
II
II

III
II
II
II
III

www.nord.com

Load Duration

Application
LUMBER INDUSTRY
Barkers
SpindIe Feed
Main Drive
Conveyors
Burner
Main or Heavy Duty
Main Iog
Re-saw, Merry-Go-Round
SIab
Transfer
Chains
FIoor
Green
Cut-Off Saws
Chain
Drag
Debarking Drums
Feeds
Edger
Gang
Trimmer
Long Deck
Log HauIs IncIine WeII Type
Log Turning Devices
Planer Feed
PIaner TiIting Hoists
RoIIs Iive-off brg. RoII Cases
Sorting TabIe
TippIe Hoist
Transfers
Chain
Craneway
Tray Drives
Veneer Lathe Drives
METAL MILLS
Draw Bench Carriage & Main Drive
Runout TabIe
Non-reversing
Group Drives
IndividuaI Drives
Reversing
SIab Pushers
Shears
Wire drawing
Wire Winding Machine
METAL STRIP PROCESSING MACHINERY
BridIes
CoiIers & UncoiIers
Edge Trimmers
FIatteners
Loopers (AccumuIators)
Pinch RoIIs
Scrap Choppers
Shears
Slitters

www.nord.com

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

II
III

II
III

II
III

II
II
III
II
III
II

II
II
III
II
III
II

II
II
III
II
III
II

II
II

II
II

II
III

II
II
III

II
II
III

III
III
III

II
II
II
III
III
III
II
II
III
II
II

II
III
II
III
III
III
II
II
III
II
II

II
III
II
III
III
III
II
II
III
II
II

II
II
II
II

II
II
II
II

III
III
II
II

II

II

II

II
III
III
II
III
II
II

II
III
III
II
III
II
II

II
III
III
II
III
II
II

II
I
I
II
I
II
II
III
I

II
I
II
II
I
II
II
III
II

II
II
II
II
I
I
II
III
II

Load Duration

Application
MILLS, ROTARY TYPE
BaII & Rod
Spur Ring Gear
HeIicaI Ring Gear
Direct Connected
Cement KiIns
Dryers & CooIers
PAPER MILLS1)
Agitator (Mixer)
Agitator for Pure Iiquors
Barking Drums
Barkers MechanicaI
Beater
Breaker Stack
CaIender2)
Chipper
Chip Feeder
Coating RoIIs
Conveyors
Chip, Bark, ChemicaI
Iog (incIuding SIab)
Couch RoIIs
Cutter
CyIinder MoIds
Dryers2)
Paper Machine
Conveyor Type
Embosser
Extruder
Fourdrinier RoIIs (IncIudes Iump Breaker,
Dandy RoII, Wire Turning, and
Return RoIIs)
Jordan
KiIn Drive
Mt. Hope RoII
Paper RoIIs
Platter
Presses FeIt & Suction
PuIper
Pumps Vacuum
ReeI (Surface Type)
Screens
Chip
Rotary
Vibrating
Size Press
SupercaIendar3)
Thickener (AC Motor)
Thickener (DC Motor)
Washer (AC Motor)
Washer (DC Motor)
Wind and Unwind Stand
Winders (Surface Type)
Yankee Dryers2)

G1142 Subject to Change Without Notice

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

III
II
III
II
II

III
II
III
II
II

III
II
III
II
II

II
II
III
III
II
II
II
III
II
II

II
II
III
III
II
II
II
III
II
II

II
II
III
III
II
II
II
III
II
II

II
III
II
III
II

II
III
II
III
II

II
III
II
III
II

II
II
II
II

II
II
II
II

II
II
II
II

II
II
II
II
II
II
II
III
II
II

II
II
II
II
II
II
II
III
II
II

II
II
II
II
II
II
II
III
II
II

II
II
III
II
II
II
II
II
II
I
II
II

II
II
III
II
II
II
II
II
II
I
II
II

II
II
III
II
II
II
II
II
II
I
II
II

47

INTRODUCTION

Engineering
AGMA Service Classes

INTRODUCTION

Engineering
AGMA Service Classes
Load Duration

Application
PLASTICS INDUSTRY
PRIMARY PROCESSING
Intensive InternaI Mixers
Batch Mixers
Continuous Mixers
Batch Drop MiII 2 smooth roIIs
Continuous Feed, HoIding &
Biend MiII CaIendars
PLASTICS INDUSTRY
SECONDARY PROCESSING
BIow MoIders
Coating
FiIm
Pipe
Pre-PIasticizers
Rods
Sheet
Tubing
PULLERS BARGE HAUL
PUMPS
CentrifugaI
Proportioning
Reciprocating
SingIe Acting, 3 or more cyIinders
DoubIe Acting, 2 or more cyIinders
Rotary
Gear Type
Lobe
Vane
RUBBER INDUSTRY
Intensive InternaI Mixers
Batch Mixers
Continuous Mixers
Mixing MiII
2 smooth roIIs
1 or 2 corrugated roIIs
Batch Drop MiII 2 smooth roIIs
Cracker Warmer 2 roII, 1 corrugated roII
Cracker 2 corrugated roIIs
HoIding, Feed & BIend MiII 2 roIIs
Rener 2 roIIs
CaIendars
SAND MULLER
SEWAGE DISPOSAI EQUIPMENT
Bar Screens
ChemicaI Feeders
Dewatering Screens
Scum Breakers
SIow or Rapid Mixers
SIudge CoIIectors
Thickener
Vacuum FiIters

48

Up to
3 hrs
per
day

III
II
II
II
II

3-10
hrs
per
day

III
II
II
II
II

Over
10 hrs
per
day

III
II
II
II
II

II
II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II
II

I
II

I
II

II
II

II
II

II
II

II
II

I
I
I

I
I
I

II
II
II

III
II

III
II

III
II

II
III
II
III
III
II
II
II
II

II
III
II
III
III
II
II
II
II

II
III
II
III
III
II
II
II
II

II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II

Load Duration

Application
SCREENS
Air Washing
Rotary Stone or GraveI
TraveIing Water Intake I
SCREW CONVEYORS
UniformIy Ioaded or Fed
Heavy Duty
SUGAR INDUSTRY
Beet SIicer
Cane Knives
Crushers
MiIIs (Iow speed end)
TEXTILE INDUSTRY
Batchers
CaIendars
Cards
Dry Cans
Dyeing Machinery
Looms
MangIes
Nappers
Pads
Siashers
Soapers
Spinners
Tenter Frames
Washers
Winders

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

I
II
I

I
II
I

II
II
I

I
I

I
II

II
II

III
II
II
III

III
II
II
III

III
II
II
III

II
II
II
II
II
II
II
II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II
II
II
II
II
II
II
II

II
II
II
II
II
II
II
II
II
II
II
II
II
II
II

Notes to GEARMOTOR SERVICE FACTOR tabIe:


1) The cIass numbers Iisted for paper miII appIications are
consistent with those shown in TAPPI (TechnicaI Association
of PuIp and Paper Industry) TechnicaI Information Sheet 040618 1967, Service Factors for Gears on major Equipment in the
Paper and PuIp Industry.
2) Anti-friction bearings onIy.
3) A CIass Number of I may be applied at base speed of a supercaIendar operating over a speed range of part-range constant
horsepower and part-range constant torque where the constant horsepower speed range is greater than 1.5 to 1. A CIass
Number of II is appIicabIe to supercaIendars operating over
the entire speed range at constant torque or where the constant horsepower speed range is Iess than 1.5 to1.

G1142 Subject to Change Without Notice

www.nord.com

Speed Reducers

Load Duration

Before an encIosed speed reducer or increaser can be selected for any application, an equivalent unit power rating (service factor = 1.0) must be determined. This is done
by muItipIying the specied power by the service factor.
Since the service factor represents the normaI relationship between the gear unit rating and the required application power, it is suggested that the service factor be
applied to the nameplate rating of the prime mover or
driven machine rating, as appIicabIe.
NORD GEAR and the user must agree upon which power, prime mover rating or driven machine requirements,
shouId dictate the seIection of the gear drive. It is necessary that the gear drive seIected have a rated unit capacity equaI to or in excess of this equivalent unit power
rating.
AII service factors Iisted are 1.0 or greater. Service factors Iess than 1.0 can be used in some appIications when
specied by the user and agreed to by NORD GEAR.
The REDUCER SERVICE FACTOR tabIe shouId be used with
caution, since much higher vaIues have occurred in some
appIications. VaIues as high as ten have been used. On
some appIications up to six times nominaI torque can occur, such as: Turbine/Generator drives, Heavy PIate and
BiIIet roIIing miIIs.
It has been deveIoped from the experience of manufacturers and users of gear drives for use in common appIications. It is suggested that service factors for speciaI appIications be agreed upon by the user and NORD
GEAR when variations of the vaIues in the tabIe may be
required.
Service factors shown are for reducers driven by motors
(eIectric or hydrauIic) and turbines (steam or gas) according to AGMA 6010. When the driver is a singIe cyIinder
or muIti-cyIinder engine, the service factors from the tabIe must be modied for the appropriate type of prime
mover.
As an exampIe, if the application is a centrifugaI bIower,
the service factor from the REDUCER SERVICE FACTOR
tabIe is 1.25 for a motor or turbine. The CONVERSION
TABLE changes this vaIue to 1.75 for a singIe cyIinder engine and 1.50 for a muIti-cyIinder engine.
CAUTION: Any user of encIosed gear drives shouId make
sure that the Iatest avaiIabIe information affecting the
seIection of a gear drive is used. When better Ioad intensity data is avaiIabIe on the driving or driven equipment, this shouId be considered when a service factor is
seIected.
Conversion Table
Electric Motor,
Steam & Gas
Turbines, Hydraulics

Single-Cylinder
Engines

Multi-Cylinder
Engines

1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00

1.50
1.75
2.0
2.25
2.50
2.75
3.00
3.25
3.50

1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25

www.nord.com

Application

AGITATORS (mixers)
Pure Liquids
Liquids and Solids
Liquids Variable Density
BLOWERS
Centrifugal
Lobe
Vane
BREWING AND DISTILLING
BottIing Machinery
Brew KettIes Continuous Duty
Cookers Continuous Duty
Mash Tubs Continuous Duty
ScaIe Hopper Frequent Starts
CAN FILLING MACHINES
CAR DUMPERS
CAR PULLERS
CLARIFIERS
CLASSIFIERS
CLAY WORKING MACHINERY
Brick Press
Briquette Machine
Pug MiII
COMPACTORS
COMPRESSORS
CentrifugaI
Lobe
Reciprocating, MuIti-CyIinder
Reciprocating, SingIe-CyIinder
CONVEYORS GENERAL PURPOSE
Uniformly loaded or fed
Not uniformly fed
Reciprocating or shaker
CRANES
Dry dock
Main hoist
Auxilliary hoist
Boom hoist
Slewing drive
Traction drive
Industrial Duty
Main hoist
CRUSHER
Stone or ore

G1142 Subject to Change Without Notice

Up to
3 hrs
per
day

3-10 Over
hrs 10 hrs
per
per
day
day

1.00
1.00
1.00

1.00
1.25
1.25

1.25
1.50
1.50

1.00
1.00
1.00

1.25
1.25
1.00

1.50
1.50
1.25

1.00
1.00
1.00
1.00
1.00
1.00
1.25
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.25
1.00
1.50
1.25
1.00
1.25

1.25
1.25
1.25
1.25
1.50
1.25
1.75
1.50
1.25
1.50

1.25
1.25
1.00
1.50

1.50
1.50
1.25
1.75

1.75
1.75
1.50
2.00

1.00
1.00
1.00
1.25

1.00
1.25
1.25
1.50

1.25
1.50
1.50
1.75

1.00
1.00
1.25

1.00
1.25
1.50

1.25
1.50
1.75

1.25
1.25
1.25
1.25
1.50

1.50
1.50
1.50
1.50
1.50

1.75
1.75
1.75
1.75
1.50

1.00

1.25

1.50

1.50

1.75

2.00

49

INTRODUCTION

Engineering
AGMA Service Factors

INTRODUCTION

Engineering
AGMA Service Factors
Load Duration

Load Duration

Application

DREDGES
Cable reels
Conveyors
Cutter Head Dives
Pumps
Screen Drives
Stackers
Winches
ELEVATORS
Bucket
CentrifugaI Discharge
Gravity Discharge
EXTRUDERS
GeneraI
PIastics
VariabIe Speed Drive
Fixed Speed Drive
Rubber
Continuous Screw Operation
Intermittent Screw Operation
FANS
CentrifugaI
Forced Draft
Induced Draft
IndustriaI & Mine
FEEDERS
Apron
BeIt
Disc
Reciprocating
Screw
FOOD INDUSTRY
CereaI Cooker
Dough Mixer
Meat Grinders
Slicers
GENERATORS AND EXCITERS
HAMMER MILLS
HOISTS
Heavy Duty
Medium Duty
Skip Hoist
LAUNDRY TUMBLERS
LAUNDRY WASHERS

50

Up to
3 hrs
per
day

3-10 Over
hrs 10 hrs
per
per
day
day

1.00
1.00
1.25
1.00
1.25
1.00
1.00

1.25
1.25
1.50
1.25
1.50
1.25
1.25

1.50
1.50
1.75
1.50
1.75
1.50
1.50

1.00
1.00
1.00

1.25
1.00
1.00

1.50
1.25
1.25

1.25

1.25

1.25

1.50
1.75

1.50
1.75

1.50
1.75

1.50
1.75

1.50
1.75

1.50
1.75

1.00
1.25
1.00
1.00

1.00
1.25
1.25
1.25

1.25
1.25
1.50
1.50

1.00
1.00
1.00
1.25
1.00

1.25
1.25
1.00
1.50
1.25

1.50
1.50
1.25
1.75
1.50

1.00
1.00
1.00
1.00
1.00
1.50

1.00
1.25
1.25
1.25
1.00
1.50

1.25
1.50
1.50
1.50
1.25
1.75

1.25
1.00
1.00
1.00
1.25

1.50
1.25
1.25
1.25
1.25

1.75
1.50
1.50
1.50
1.50

Application

LUMBER INDUSTRY
Barkers
SpindIe Feed
Main Drive
Conveyors
Burner
Main or Heavy Duty
Main Iog
Re-saw, Merry-Go-Round
SIab
Transfer
Chains
FIoor
Green
Cut-Off Saws
Chain
Drag
Debarking Drums
Feeds
Edger
Gang
Trimmer
Long Deck
Log HauIs IncIine WeII Type
Log Turning Devices
Planer Feed
PIaner TiIting Hoists
RoIIs Iive-off brg. RoII Cases
Sorting TabIe
TippIe Hoist
Transfers
Chain
Causeway
Tray Drives
METAL MILLS
Draw Bench Carriage & Main Drive
Runout TabIe
Non-reversing
Group Drives
IndividuaI Drives
Reversing
SIab Pushers
Shears
Wire drawing
Wire Winding Machine

G1142 Subject to Change Without Notice

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

1.25
1.50
1.25

1.25
1.50
1.25

1.50
1.50
1.50

1.25
1.50
1.50
1.25
1.50
1.25

1.25
1.50
1.50
1.25
1.50
1.25

1.50
1.50
1.75
1.50
1.75
1.50

1.50
1.50

1.50
1.50

1.50
1.50

1.50
1.50
1.50

1.50
1.50
1.50

1.50
1.50
1.75

1.25
1.50
1.25
1.50
1.50
1.50
1.25
1.50
1.50
1.25
1.25

1.25
1.50
1.25
1.50
1.50
1.50
1.25
1.50
1.50
1.50
1.25

1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50

1.50
1.50
1.25

1.50
1.50
1.25

1.50
1.50
1.50

1.00

1.25

1.50

1.00
1.50
1.50
1.25
1.50
1.00
1.00

1.25
1.50
1.50
1.25
1.50
1.25
1.25

1.50
1.75
1.75
1.50
1.75
1.50
1.50

www.nord.com

Load Duration

Application

METAL STRIP PROCESSING MACHINERY


Bridles
Coilers and uncoilers
Edge Trimmers
Flatteners
Loopers (accumulators)
Pinch rolls
Scrap choppers
Shears
Slitters
MILLS, ROTARY TYPE
BaII & Rod
Spur Ring Gear
HeIicaI Ring Gear
Direct Connected
Cement KiIns
Dryers & CooIers
MIXERS CONCRETE
PAPER MILLS1)
Agitator (Mixer)
Agitator for Pure Iiquors
Barking Drums
Barkers MechanicaI
Beater
Breaker Stack
CaIender2)
Chipper
Chip Feeder
Coating RoIIs
Conveyors
Chip, Bark, ChemicaI
Iog (incIuding SIab)
Couch RoIIs
Cutter
CyIinder MoIds
Dryers2)
Paper Machine
Conveyor Type
Embosser
Extruder
Fourdrinier RoIIs (IncIudes Iump Breaker,
Dandy RoII, Wire Turning, and
Return RoIIs)
Jordan
KiIn Drive
Mt. Hope RoII
Paper RoIIs

www.nord.com

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

1.25
1.00
1.00
1.00
1.00
1.00
1.00
1.50
1.00

1.25
1.00
1.25
1.25
1.00
1.25
1.25
1.50
1.25

1.50
1.25
1.50
1.50
1.00
1.50
1.50
1.75
1.50

1.50
1.50
1.50
1.50
1.50
1.00

1.50
1.50
1.50
1.50
1.50
1.25

1.75
1.50
1.75
1.50
1.50
1.50

1.50
1.25
1.75
1.75
1.50
1.25
1.25
1.75
1.50
1.25

1.50
1.25
1.75
1.75
1.50
1.25
1.25
1.75
1.50
1.25

1.50
1.25
1.75
1.75
1.50
1.25
1.25
1.75
1.50
1.25

1.25
1.75
1.25
1.75
1.25

1.25
1.75
1.25
1.75
1.25

1.25
1.75
1.25
1.75
125

1.25
1.25
1.25
1.50

1.25
1.25
1.25
1.50

1.25
1.25
1.25
1.50

1.25
1.25
1.50
1.25
1.25

1.25
1.25
1.50
1.25
1.25

1.25
1.25
1.50
1.25
1.25

Load Duration

Application

PAPER MILLS (cont)


Presses FeIt & Suction
PuIper
Pumps Vacuum
ReeI (Surface Type)
Screens
Chip
Rotary
Vibrating
Size Press
SupercaIendar3)
Thickener (AC Motor)
Thickener (DC Motor)
Washer (AC Motor)
Washer (DC Motor)
Wind and Unwind Stand
Winders (Surface Type)
Yankee Dryers2)
PLASTICS INDUSTRY
PRIMARY PROCESSING
Intensive InternaI Mixers
Batch Mixers
Continuous Mixers
Batch Drop MiII 2 smooth roIIs
Cont. Feed, HoIding & Biend MiII
CaIendars
PLASTICS INDUSTRY
SECONDARY PROCESSING
BIow MoIders
Coating
FiIm
Pipe
Pre-PIasticizers
Rods
Sheet
Tubing
PULLERS BARGE HAUL
PUMPS
CentrifugaI
Proportioning
Reciprocating
SingIe Acting, 3 or more cyIinders
DoubIe Acting, 2 or more cyIinders
Rotary
Gear Type
Lobe
Vane

G1142 Subject to Change Without Notice

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

1.25
1.50
1.50
1.25

1.25
1.50
1.50
1.25

1.25
1.75
1.50
1.50

1.50
1.50
1.75
1.25
1.25
1.50
1.25
1.50
1.25
1.00
1.25
1.25

1.50
1.50
1.75
1.25
1.25
1.50
1.25
1.50
1.25
1.00
1.25
1.25

1.50
1.50
1.75
1.25
1.25
1.50
1.25
1.50
1.25
1.00
1.25
1.25

1.75
1.50

1.75
1.50

1.75
1.50

1.25
1.50

1.25
1.50

1.25
1.50

1.50
1.25
1.25
1.25
1.50
1.25
1.25
1.25
1.00

1.50
1.25
1.25
1.25
1.50
1.25
1.25
1.25
1.50

1.50
1.25
1.25
1.25
1.50
1.25
1.25
1.50
1.75

1.00
1.00

1.00
1.25

1.25
1.50

1.00
1.00

1.25
1.25

1.50
1.50

1.00
1.00
1.00

1.00
1.00
1.00

1.50
1.25
1.25

51

INTRODUCTION

Engineering
AGMA Service Factors

INTRODUCTION

Engineering
AGMA Service Factors
Load Duration

Load Duration

Application

RUBBER INDUSTRY
Intensive InternaI Mixers
Batch Mixers
Continuous Mixers
Mixing MiII
2 smooth roIIs
1 or 2 corrugated roIIs
Batch Drop MiII 2 smooth roIIs
Cracker Warmer 2 roII, 1 corrugated roII
Cracker 2 corrugated roIIs
HoIding, Feed & BIend MiII 2 roIIs
Rener 2 roIIs
CaIendars
SAND MILLER
SEWAGE DISPOSAI EQUIPMENT
Bar Screens
ChemicaI Feeders
Dewatering Screens
Scum Breakers
SIow or Rapid Mixers
SIudge CoIIectors
Thickener
Vacuum FiIters
SCREENS
Air Washing
Rotary Stone or GraveI
TraveIing Water Intake I
SCREW CONVEYORS
UniformIy Ioaded or Fed
Heavy Duty
SUGAR INDUSTRY
Beet SIicer
Cane Knives
Crushers
MiIIs (Iow speed end)

52

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

1.50
1.25

1.75
1.50

1.75
1.50

1.50
1.75
1.50
1.75
1.75
1.25
1.50
1.50
1.00

1.50
1.75
1.50
1.75
1.75
1.25
1.50
1.50
1.25

1.50
1.75
1.50
1.75
1.75
1.25
1.50
1.50
1.50

1.00
1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.25
1.25
1.25
1.00
1.25
1.25

1.25
1.25
1.50
1.50
1.50
1.25
1.50
1.50

1.00
1.00
1.00

1.00
1.25
1.00

1.25
1.50
1.25

1.50
1.50
1.50
1.50

1.50
1.50
1.50
1.50

1.75
1.50
1.50
1.50

Application

TEXTILE INDUSTRY
Batchers
CaIendars
Cards
Dry Cans
Dyeing Machinery
Looms
MangIes
Nappers
Pads
Siashers
Soapers
Spinners
Tenter Frames
Washers
Winders

Up to
3 hrs
per
day

3-10
hrs
per
day

Over
10 hrs
per
day

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25

1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50

Notes to REDUCER SERVICE FACTOR tabIe:


1) Service factors for paper miII appIications are applied to the nameplate rating of the eIectric motor at
the motor rated based speed.
2) Anti-friction bearings onIy. Use 1.5 for sIeeve bearings.
3) A service factor of 1.0 may be applied at base speed
of a super caIender operating over-speed range of
part range constant horsepower, part range constant
torque where the constant horsepower speed range
is greater that 1.5 to 1. A service factor of 1.25 is appIicabIe to super caIenders operating over the entire
speed range at constant torque or where the constant horsepower speed range is Iess than 1.5 to 1.
Explanatory notes.

G1142 Subject to Change Without Notice

www.nord.com

lb
Approximate Gearmotor Weights [lb]
Type

63S

63L

71S

71L

80S

80L

90S

90L

100L

100LA

132S

SK 92072

19

20

23

25

29

31

37

42

SK 92172

30

31

34

36

40

42

49

53

SK 92372

43

45

47

49

53

55

62

66

75

82

SK 92672

81

84

86

89

92

98

103

111

118

169

SK 92772

105

107

114

118

127

134

184

Above weights are approximate. Depending upon ratio, oil quantity and optional equipment, reducer weights may be different than shown.
Exact weights can be obtained after the unit is fully assembled.

Approximate Reducer Weights [lb]


Type

56C

140TC

180TC

210TC

250TC

SK 92072

15

24

24

SK 92172

26

35

35

SK 92372

40

49

49

60

SK 92672

79

86

86

97

112

SK 92772

99

101

101

112

128

128

Above weights are approximate. Depending upon ratio, oil quantity and optional equipment, reducer weights may be different than shown.
Exact weights can be obtained after the unit is fully assembled.

www.nord.com

G1142 Subject to Change Without Notice

53

INTRODUCTION

92 Series Bevel
Weights

INTRODUCTION

Notes

54

G1142 Subject to Change Without Notice

www.nord.com

92 Series Gearmotors
Gearmotor
Selection
0.16 hp
0.25 hp
0.33 hp
0.5 hp
0.75 hp
1 hp
1.5 hp
2 hp
3 hp
5 hp
7.5 hp

DRIVESYSTEMS

www.nord.com
92 Series Bevel
Ordering Guide
Gear Unit

SK

Shaft/Mounting

SK 92372 - 90 S/4
92 Series Helical Bevel Unit
Foot Mounted,
Reducer Options
Motor/Input
Solid Shaft Side A
Two Stage-
see pages XXX

92072
92172
92372
92672
92772

Gear Unit
9012.1
9013.1
9016.1
9017.1
9022.1
9023.1
9032.1
9033.1
9042.1
9043.1
9052.1
9053.1
9072.1
9082.1
9086.1
9092.1

9072.1/32
9072.1/42
9082.1/42
9082.1/52
9086.1/52
9092.1/52

Motor
Power

see pages XXX

VXZ - Solid Shaft/Foot/B14 Flange


AZ - Hollow Shaft/B14 Flange
SK 92372LX - 90 S/4
VXF - Solid Shaft/Foot/B5 Flange
AF - Hollow Shaft/B5 Flange
Unit
LXZ - Double92
SolidSeries
Shaft/Foot/Helical
B14 Flange Bevel
AX - Hollow
Shaft/Foot Mount
Foot Mounted,
AXZ - Hollow Shaft/Footed/B14 Flange
Double Solid ShaftAXF - Hollow Shaft/Footed/B5 Flange

Two Stage

Reducer Options

B - Fixing Element Kit


H - Cover
H66 - IP66 Cover
D - Torque Arm
K - Torque Tab
PR - Flange Pilot Removal
SH - Shrink Disc & Cover
VSH - Heavy Duty Shrink Disc & Cover

Gear
Ratio

Pn

n2

Ta

[hp]

[rpm]

[Ib-in]

15

65
57
49
45
39
32
28
25
20

14614
16714
19348
21223
24023
29153
33352
38599
47111

2.8
2.5
2.2
2
1.8
1.5
1.3
1.1
0.9

III
III
III
III
II
II
I
I
*

27.35
31.28
36.21
39.72
44.96
54.56
62.42
72.24
88.17

50
43
35

18803
21966
26903

3.3
3.1
2.7

III
III
III

35.19
41.11
50.35

fB

itot

Motor Options

Shaft/Mounting
- Solid Shaft/Foot Mount
VZ - Solid Shaft/B14 Flange
VF - Solid Shaft/B5 Flange
LX - Double Solid Shaft/Foot

Output Output Service AGMA


Speed Torque Factor
Class

VL - Heavy Duty Output Bearings Vl - Viton Oil Seals


VL2
Bearing Design- 90
OSG - Oil Sight Glass
SK- Spread
92372VF
S/4
VL3
Safe Spread
Bearings Bevel
OA
- Oil Expansion Chamber
92- Oil
Series
Helical
Unit
VL4
- Drywell
Solid
Shaft Side A OC - Oil Cooler
B5-Flange
Side
SM5
Stainless Steel
Shaft A
WC - Cooling Cover
Two
Stage
SWA
- Special
Hollow Shaft
LL - Long Term Storage
SWV - Special Solid Shaft
Magnetic Drain Plug
Cross Drilled Shaft
Additional Drain Plug

55

92 Series Bevel
Ordering Guide
Gear Unit

SK

Shaft/Mounting

Reducer Options

Gear Unit

GEARMOTORS

:1
see pages 58 - 71
OR
Output Speed

rpm

H - Hollow Shaft Cover 18


D - Torque Arm 19
LL - Long Term Storage 21
NEMA
Adapter
N56C
N140TC
N180TC
N210TC
N250TC

see page 15

SWA - Special Hollow Shaft 19


SS - Special Shrink Disc 19

Other Speeds Available

Paint

M5

M4

M3

B5 Flange Side
(if required)

Lubricant

Standard Stainless Steel Paint


NSD+ (gray)
NSD+W (white)
NSD-X3 (gray)
NSD-X3W (white)
Casting Primed
Special _______

B5 Flange Diameter
(if required)

Standard
Synthetic
Food Grade
Other _______

Torque Arm Side


Shrink Disc Side
& Location (if required)
(if required)

Side A

Side B
Location
see page 15

see page 15

Side A

Side B

H66 Side
(if required)

H66 Side A

H66 Side B

see page 15

see page 15

TB2

TB1

Terminal Box Pos.

TB1

TB2

TB3

TB4

TB3

Voltage & Frequency

230/460V-60Hz (460V only 40 hp)

575V-60Hz

208V-60Hz

400V-50Hz

115/230V-60Hz, 1 ph.

Other ___________

Integral Energy
Efcent Motors
80LH/4 - 1hp
90SH/4 - 1.5hp
90LH/4 - 2hp
100LH/4 - 3hp
112MH/4 - 5hp
132SH/4 - 7.5hp
132MH/4 - 10hp

63S/4 - 0.16hp
63L/4 - 0.25hp
71S/4 - 0.33hp
71L/4 - 0.50hp
80S/4 - 0.75hp
80L/4 - 1hp
90S/4 - 1.5hp
90L/4 - 2hp
100L/4 - 3hp
100LA/4 - 5hp
112M/4 - 5.4hp
132S/4 - 7.5hp
132M/4 - 10hp
Other Speeds Available

Flange Side A

Flange Side B

Flange Side A&B


see pages 113 - 114

Vl - Flouro-rubber Seals 20
OSG - Oil Sight Glass 20
MDP - Magnetic Drain Plug 21
ADP - Additional Drain Plug 21

Integral Motors

M2

Gearmotor Only Details

56

SM5 - Stainless Steel Shaft 19

M1

M6

see pages 58 - 71

Shaft Side A

Shaft Side B

Shaft Side A&B

PR - Flange Pilot Removal 17

IEC
Adapter
IEC 63
IEC 71
IEC 80
IEC 90
IEC 100
IEC 112
IEC 132
IEC160

Mounting Position
M1
M2
M3
M4
M5
M6
Special _______

Hollow Shaft
Solid Shaft Side
Diameter (if required)
(if required)

B - Fixing Element Kit 19

Product Specications
Ratio

see page 126

Reducer Options

Input
Shaft
W

see page 23

AFSH - Hollow Shaft/B5 Flange/Shrink Disc


AZSH - Hollow Shaft/B14 Flange/Shrink Disc

Motor Options

Shaft/Mounting
AX - Hollow Shaft/Foot Mount
AF - Hollow Shaft/B5 Flange
AZ - Hollow Shaft/B14 Flange

- Solid Shaft/Foot Mount


VF - Solid Shaft/B5 Flange
VZ - Solid Shaft/B14 Flange
VFL - Double Solid Shaft /B5 Flange
LX - Double Solid Shaft/Foot
LXZ - Double Solid Shaft/Foot/ B14 Flange

92072
92172
92372
92672
92772

Motor/Input

TB4

Mtg. Pos. M1 Shown


G1142 - Subject to Change Without Notice

Conduit Entry Loc.

CE I
CE IV

CE II

CE III

CE IV
Brakemotor

CE III*

CE II

CE I*

Mtg. Pos. M1 Shown

www.nord.com

92 Series Bevel
Ordering Guide
Examples of Available Helical-bevel Units
with Hollow Shaft Design

SK 92372 - 90 S/4
92 Series Helical Bevel Unit
Foot Mounted,
Solid Shaft Side A
Two Stage

SK 92372AZ - 90 S/4
92 Series Helical Bevel Unit
Hollow Shaft,
B14 Flange Side A & B
Two Stage

SK 92372LX - 90 S/4
92 Series Helical Bevel Unit
Foot Mounted,
Double Solid Shaft
Two Stage

SK 92372AF - 90 S/4
92 Series Helical Bevel Unit
Hollow Shaft,
B5 Flange Side A
Two Stage

SK 92372VF - 90 S/4
92 Series Helical Bevel Unit
Solid Shaft Side A
B5 Flange Side A
Two Stage

SK 92372AX - 90 S/4
92 Series Helical Bevel Unit
Hollow Shaft,
Foot Mounted
Two Stage

SK 92372VZ - 90 S/4
92 Series Helical Bevel Unit
Solid Shaft Side A
B14 Flange Side A & B
Two Stage

SK 92372AZSH - 90 S/4
92 Series Helical Bevel Unit
Hollow Shaft,
B14 Flange Side A & B,
Shrink Disc & Cover Side B
Two Stage

SK 92372VZL - 90 S/4
92 Series Helical Bevel Unit
Double Solid Shaft
B14 Flange Side A & B
Two Stage

SK 92372AZD - 90 S/4
92 Series Helical Bevel Unit
Hollow Shaft,
B14 Flange Side A & B
Torque Arm Side A at 180
Two Stage

www.nord.com

G1142 - Subject to Change Without Notice

GEARMOTORS

Examples of Available Helical-bevel Units


with Solid Shaft Design

57

0.16 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

0.16

442
324
294
264
216
189
176
154
125
97
83
73
64
56
49
43
36
31

23
31
35
38
47
54
58
66
81
105
122
139
157
180
207
237
285
326

18.9
16.8
18.8
15.4
16.8
14.9
13.8
12.1
8.2
5.1
6.6
5.7
5.1
3.4
3.2
3.0
1.4
1.4

III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
II
II

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39
30.15
34.73
39.67
47.83
54.65

610
673
695
718
738
738
738
738
738
736
736
736
734
734
731
729
725
722

864
979
1024
1069
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148

SK 92072 - 63S/4

19

78

415
356
319
281
241
212
187
164
144
126
109
90
60
53
47
41
36
32
27
24

24
28
32
36
42
48
54
62
70
80
93
112
168
193
215
246
280
320
378
431

21.3
20.2
19.7
18.8
20.0
18.5
17.2
15.7
14.4
13.2
11.4
6.7
6.3
5.5
4.1
4.1
2.4
2.5
1.2
1.1

III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
I
I

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
28.24
32.27
36.11
41.26
46.90
53.59
63.29
72.31

729
767
767
767
767
765
765
765
765
765
765
765
763
761
758
758
754
752
745
738

1008
1071
1121
1184
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 63S/4

30

84

262
232
205
180
157
149
131
116
50
44
39
34
31
27

39
44
49
56
65
68
78
87
202
230
260
297
328
375

22.0
22.0
22.4
22.4
21.5
20.0
20.0
19.1
8.1
7.3
5.1
5.1
3.0
3.0

III
III
III
III
III
III
III
III
III
III
III
III
III
III

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
33.80
38.62
43.52
49.73
55.00
62.85

1067
1067
1067
1067
1067
1067
1067
1067
1064
1062
1062
1060
1060
1058

1811
1908
2012
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 63S/4

43

90

(AGMA Class I = fB 1.0 - 1.39

58

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

www.nord.com

0.16, 0.25 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

0.16

134
121
106
33
29

75
84
96
309
353

24.7
24.2
24.2
9.9
9.4

III
III
III
III
III

12.64
14.08
16.08
51.86
59.25

1395
1395
1395
1391
1391

2700
2700
2700
2700
2700

SK 92672 - 63S/4

80

96

109
95
30
27

93
106
334
382

24.2
24.2
10.6
10.7

III
III
III
III

15.60
17.83
56.02
64.01

1863
1863
1861
1861

2700
2700
2700
2700

SK 92772 - 63S/4

95

102

436
321
290
261
213
187
174
152
124
96
82
72
64
56
48
42

36
50
55
62
75
86
93
106
130
168
195
223
252
288
332
379

12.0
10.5
11.8
9.6
10.5
9.3
8.6
7.5
5.1
3.2
4.1
3.6
3.2
2.1
2.0
1.9

III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
II

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39
30.15
34.73
39.67

608
668
691
716
738
738
738
736
736
734
734
731
729
725
720
716

855
968
1015
1053
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148

SK 92072 - 63L/4

20

78

410
352
315
278
239
210
185
162
142
125
108
89
59
52
47
41
36
31

39
46
51
58
67
77
87
99
113
129
149
180
270
308
345
394
448
512

13.3
12.6
12.3
11.8
12.5
11.6
10.7
9.8
9.0
8.2
7.1
4.2
3.9
3.4
2.6
2.6
1.5
1.6

III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
II
II

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
28.24
32.27
36.11
41.26
46.90
53.59

729
763
765
765
765
765
765
765
765
765
763
761
756
752
747
743
736
725

1001
1064
1116
1175
1253
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 63L/4

31

84

0.25

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

59

GEARMOTORS

Motor
Power

0.25, 0.33 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

0.25

259
230
203
177
155
147
129
115
50
44
39
34
31
27

62
70
79
91
104
109
124
140
323
369
416
475
526
601

13.7
13.7
14.0
14.0
13.4
12.5
12.5
11.9
5.1
4.6
3.2
3.2
1.9
1.8

III
III
III
III
III
III
III
III
III
III
III
III
II
II

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
33.80
38.62
43.52
49.73
55.00
62.85

1067
1067
1067
1067
1067
1067
1067
1064
1060
1058
1055
1051
1049
1042

1811
1904
2005
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 63L/4

45

90

133
119
104
32
28

121
135
154
496
566

15.4
15.1
15.1
6.2
5.9

III
III
III
III
III

12.64
14.08
16.08
51.86
59.25

1395
1393
1393
1386
1384

2700
2700
2700
2700
2700

SK 92672 - 63L/4

81

96

108
94
30
26

149
170
535
612

15.1
15.1
6.6
6.7

III
III
III
III

15.60
17.83
56.02
64.01

1863
1863
1856
1856

2700
2700
2700
2700

SK 92772 - 63L/4

97

102

444
326
295
266
217
190
177
155
126
97
84
73
65
57
49
43

47
65
72
80
97
111
120
137
167
217
252
288
326
373
429
490

9.2
8.1
9.1
7.4
8.1
7.2
6.7
5.8
4.0
2.4
3.2
2.8
2.4
1.7
1.5
1.4

III
III
III
III
III
III
III
III
III
III
III
III
III
II
II
II

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39
30.15
34.73
39.67

601
662
682
707
738
736
736
736
734
731
729
725
722
716
709
700

839
950
990
1031
1118
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148

SK 92072 - 71S/4

23

78

0.33

(AGMA Class I = fB 1.0 - 1.39

60

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

www.nord.com

0.33 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

0.33

417
358
321
283
243
213
189
165
145
127
110
91
61
53
47
41
36
32

51
59
66
75
87
99
112
128
146
167
193
232
349
399
446
510
580
662

10.3
9.7
9.5
9.1
9.7
8.9
8.3
7.6
7.0
6.4
5.5
3.2
3.0
2.7
2.0
2.0
1.1
1.2

III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
III
I
I

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
28.24
32.27
36.11
41.26
46.90
53.59

720
756
765
765
765
765
765
765
763
763
761
758
747
743
736
727
713
695

986
1049
1098
1157
1235
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 71S/4

34

84

263
234
206
181
158
150
131
117
51
44
39
34
31
27

80
90
102
117
134
141
161
181
418
477
538
614
680
777

10.6
10.6
10.8
10.8
10.4
9.7
9.7
9.2
3.9
3.5
2.5
2.4
1.4
1.4

III
III
III
III
III
III
III
III
III
III
III
III
II
II

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
33.80
38.62
43.52
49.73
55.00
62.85

1067
1067
1067
1067
1064
1064
1064
1064
1055
1051
1046
1042
1035
1026

1782
1877
1976
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 71S/4

47

90

135
121
106
33
29

156
174
199
641
732

11.9
11.7
11.7
4.8
4.5

III
III
III
III
III

12.64
14.08
16.08
51.86
59.25

1393
1393
1393
1379
1375

2700
2700
2700
2700
2700

SK 92672 - 71S/4

84

96

110
96
31
27

193
220
692
791

11.7
11.7
5.1
5.1

III
III
III
III

15.60
17.83
56.02
64.01

1861
1861
1854
1852

2700
2700
2700
2700

SK 92772 - 71S/4

99

102

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

61

GEARMOTORS

Motor
Power

0.5 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

0.5

447
328
297
267
219
191
178
156
127
98
84
74
65
57
50
43

71
95
105
117
143
163
176
201
246
319
370
423
480
548
631
721

6.1
5.5
6.2
5.0
5.5
4.9
4.5
4.0
2.7
1.7
2.2
1.9
1.7
1.1
1.1
1.0

III
III
III
III
III
III
III
III
III
II
III
II
II
I
I
I

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39
30.15
34.73
39.67

592
653
673
693
736
734
734
731
729
722
716
709
702
689
673
650

819
920
961
995
1078
1136
1148
1148
1148
1148
1148
1148
1148
1148
1148
1148

SK 92072 - 71L/4

25

78

420
361
323
285
244
215
190
166
146
128
110
92
61
53
48
42
37
32

75
87
97
110
128
146
165
189
215
245
284
342
513
587
657
750
853
974

7.0
6.6
6.5
6.2
6.6
6.1
5.6
5.2
4.7
4.3
3.7
2.2
2.1
1.8
1.3
1.4
0.8
0.8

III
III
III
III
III
III
III
III
III
III
III
III
III
II
I
II
*
*

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
28.24
32.27
36.11
41.26
46.90
53.59

713
752
765
765
765
763
763
761
761
758
754
749
725
711
698
675
646
605

970
1031
1076
1132
1202
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 71L/4

36

84

265
235
207
182
159
151
132
117
51
45
40
35
31
27

118
133
151
172
197
207
237
266
615
702
791
904
1000
1143

7.2
7.2
7.4
7.4
7.1
6.6
6.6
6.3
2.7
2.4
1.7
1.7
1.0
1.0

III
III
III
III
III
III
III
III
III
III
II
II
I
I

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
33.80
38.62
43.52
49.73
55.00
62.85

1067
1064
1064
1064
1064
1064
1062
1062
1042
1033
1024
1010
997
974

1760
1850
1949
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 71L/4

49

90

(AGMA Class I = fB 1.0 - 1.39

62

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

www.nord.com

0.5, 0.75 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

0.5

136
122
107
33
29

230
256
292
943
1077

8.1
7.9
7.9
3.2
3.1

III
III
III
III
III

12.64
14.08
16.08
51.86
59.25

1393
1393
1391
1364
1352

2700
2700
2700
2700
2700

SK 92672 - 71L/4

86

96

110
96
31
27

284
324
1019
1164

7.9
7.9
3.5
3.5

III
III
III
III

15.60
17.83
56.02
64.01

1861
1861
1843
1836

2700
2700
2700
2700

SK 92772 - 71L/4

101

102

444
326
295
266
217
190
177
155
126
97
84
73
65

106
145
160
178
218
249
268
306
375
486
564
644
730

4.1
3.6
4.1
3.3
3.6
3.2
3.0
2.6
1.8
1.1
1.4
1.2
1.1

III
III
III
III
III
III
III
III
II
I
II
I
I

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39

583
639
659
680
718
729
727
725
716
700
686
668
648

790
882
918
945
1019
1069
1091
1139
1148
1148
1148
1148
1148

SK 92072 - 80S/4

29

78

417
358
321
283
243
213
189
165
145
127
110
91
75
66
61
53
47
41

113
132
148
167
195
222
251
287
327
373
432
520
631
720
782
893
999
1142

4.6
4.3
4.3
4.1
4.3
4.0
3.7
3.4
3.1
2.8
2.5
1.4
1.7
1.5
1.4
1.2
0.9
0.9

III
III
III
III
III
III
III
III
III
III
III
II
II
II
II
I
*
*

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
22.78
26.03
28.24
32.27
36.11
41.26

707
740
763
763
761
758
756
754
749
745
738
725
702
682
666
632
594
531

947
1008
1049
1105
1166
1222
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 80S/4

40

84

0.75

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

G1142 - Subject to Change Without Notice

* = fB < 1.0)

63

GEARMOTORS

Motor
Power

0.75, 1.0 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

0.75

263
234
206
181
158
150
131
117
70
62
55
51
44
39
34

180
203
229
262
300
315
360
405
673
759
867
936
1069
1205
1376

4.7
4.7
4.8
4.8
4.6
4.3
4.3
4.1
2.8
2.7
1.9
1.8
1.6
1.1
1.1

III
III
III
III
III
III
III
III
III
III
II
II
II
I
I

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
24.33
27.41
31.32
33.80
38.62
43.52
49.73

1064
1064
1062
1062
1060
1060
1058
1055
1035
1026
1015
1006
988
963
932

1733
1818
1910
2014
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 80S/4

53

90

135
121
106
46
41
36
33
29

350
390
445
1033
1164
1329
1435
1640

5.3
5.2
5.2
2.8
2.6
2.5
2.1
2.0

III
III
III
III
III
III
III
III

12.64
14.08
16.08
37.32
42.04
48.03
51.86
59.25

1391
1388
1388
1357
1346
1330
1319
1296

2700
2700
2700
2700
2700
2700
2700
2700

SK 92672 - 80S/4

89

96

110
96
42
37
33
31
27

432
494
1128
1271
1453
1551
1772

5.2
5.2
3.5
3.5
3.5
2.3
2.3

III
III
III
III
III
III
III

15.60
17.83
40.77
45.93
52.48
56.02
64.01

1859
1859
1838
1832
1823
1816
1802

2700
2700
2700
2700
2700
2700
2700

SK 92772 - 80S/4

105

102

429
315
285
256
210
184
170
149
122
81
71

147
201
222
247
302
345
372
425
521
783
894

2.9
2.6
2.9
2.4
2.6
2.3
2.1
1.9
1.3
1.0
0.9

III
III
III
III
III
III
III
II
I
I
*

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
20.37
23.28

581
632
648
668
704
720
716
709
693
635
599

772
851
884
909
968
1015
1026
1069
1091
1148
1148

SK 92072 - 80L/4
SK 92072 - 80LH/4

31

78

1.0

(AGMA Class I = fB 1.0 - 1.39

64

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

www.nord.com

1.0 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

1.0

402
346
310
273
234
206
182
159
140
122
106
88
72
63
58
51

158
183
205
232
270
308
348
398
454
518
600
722
875
1000
1085
1240

3.3
3.1
3.1
2.9
3.1
2.9
2.7
2.4
2.2
2.0
1.8
1.0
1.2
1.1
1.0
0.9

III
III
III
III
III
III
III
III
III
III
II
I
I
I
I
*

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
22.78
26.03
28.24
32.27

704
738
761
758
756
752
747
743
734
725
709
682
639
594
558
477

938
990
1033
1080
1139
1188
1240
1260
1260
1260
1260
1260
1260
1260
1260
1260

SK 92172 - 80L/4
SK 92172 - 80LH/4

42

84

254
225
199
174
152
145
127
113
68
60
53
49
43

249
281
318
364
416
438
500
563
935
1053
1203
1298
1484

3.4
3.4
3.5
3.5
3.3
3.1
3.1
3.0
2.0
1.9
1.4
1.3
1.1

III
III
III
III
III
III
III
III
III
II
II
I
I

6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
24.33
27.41
31.32
33.80
38.62

1062
1062
1060
1058
1055
1053
1049
1044
1006
990
965
947
907

1721
1811
1895
1996
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 80L/4
SK 92372 - 80LH/4

55

90

131
117
103
44
39
34
32
28

486
541
618
1434
1615
1845
1992
2276

3.8
3.8
3.8
2.0
1.9
1.8
1.5
1.5

III
III
III
III
II
II
II
II

12.64
14.08
16.08
37.32
42.04
48.03
51.86
59.25

1386
1384
1382
1319
1298
1267
1244
1195

2700
2700
2700
2700
2700
2700
2700
2700

SK 92672 - 80L/4
SK 92672 - 80LH/4

92

96

106
93
40
36
31
29
26

599
685
1566
1764
2016
2152
2459

3.8
3.8
2.5
2.5
2.5
1.6
1.7

III
III
III
III
III
II
II

15.60
17.83
40.77
45.93
52.48
56.02
64.01

1856
1854
1816
1802
1784
1773
1746

2700
2700
2700
2700
2700
2700
2700

SK 92772 - 80L/4
SK 92772 - 80LH/4

107

102

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

65

GEARMOTORS

Motor
Power

1.5 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

1.5

431
287

219
330

2.8
2.1

III
III

3.85
5.79

558
617

707
797

SK 92072 - 90S/4
SK 92072 - 90SH/4

37

78

405
348
311
275
236
207
183
160

234
272
304
344
401
457
517
591

2.8
2.6
2.5
2.3
2.1
1.9
1.8
1.6

III
III
III
III
III
II
II
II

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37

686
716
738
747
743
734
725
711

891
934
968
1008
1055
1094
1130
1172

SK 92172 - 90S/4
SK 92172 - 90SH/4

49

84

313
278
256
227
200
175
153
146
128
113
97
86
76
68
61
53

302
340
370
417
473
540
618
650
742
835
973
1095
1252
1387
1563
1786

3.7
3.7
3.5
3.5
3.3
2.9
2.6
2.7
2.3
2.0
2.1
1.9
1.4
1.3
1.3
0.9

III
III
III
III
III
III
III
III
III
III
III
II
II
I
I
*

5.30
5.97
6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
17.06
19.21
21.95
24.33
27.41
31.32

1028
1060
1058
1055
1051
1046
1040
1037
1028
1019
1001
983
956
929
887
826

1539
1609
1654
1737
1811
1904
1989
2025
2025
2025
2025
2025
2025
2025
2025
2025

SK 92372 - 90S/4
SK 92372 - 90SH/4

62

90

342
304
191
170
151
131
118
103
63
55
49
44
39
35

277
311
497
558
628
721
803
917
1514
1706
1949
2128
2397
2739

4.5
4.5
4.0
3.9
3.9
3.7
3.6
3.6
1.9
1.8
1.7
1.4
1.3
1.2

III
III
III
III
III
III
III
III
II
II
II
II
I
I

4.85
5.46
8.71
9.78
11.02
12.64
14.08
16.08
26.55
29.91
34.17
37.32
42.04
48.03

1310
1357
1386
1384
1379
1375
1370
1364
1310
1287
1251
1222
1172
1094

1892
1989
2374
2480
2597
2700
2700
2700
2700
2700
2700
2700
2700
2700

SK 92672 - 90S/4
SK 92672 - 90SH/4

98

96

(AGMA Class I = fB 1.0 - 1.39

66

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

www.nord.com

1.5, 2.0 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

1.5

306
272
153
134
119
106
93
58
52
45
41
36
32

310
348
620
709
793
890
1017
1622
1827
2088
2325
2619
2993

4.5
4.5
4.0
4.0
3.9
3.6
3.6
3.3
3.1
2.8
1.7
1.7
1.7

III
III
III
III
III
III
III
III
III
III
II
II
II

5.43
6.11
10.88
12.43
13.91
15.60
17.83
28.44
32.04
36.61
40.77
45.93
52.48

1346
1395
1665
1733
1796
1847
1843
1814
1798
1780
1757
1730
1688

2012
2115
2648
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700

SK 92772 - 90S/4
SK 92772 - 90SH/4

114

102

2.0

431
287

292
439

2.1
1.6

III
II

3.85
5.79

538
585

650
711

SK 92072 - 90L/4
SK 92072 - 90LH/4

42

78

405
348
311
275
236
207
183
160

311
362
404
458
534
608
688
787

2.1
2.0
1.9
1.7
1.6
1.5
1.4
1.2

III
III
II
II
II
II
II
I

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37

668
695
713
734
722
709
691
666

842
882
911
938
977
1001
1028
1051

SK 92172 - 90L/4
SK 92172 - 90LH/4

53

84

313
278
256
227
200
175
153
146
128
113
97
86
76
68
61

402
453
492
555
629
718
822
864
987
1111
1294
1457
1665
1846
2079

2.7
2.7
2.6
2.6
2.5
2.2
1.9
2.0
1.7
1.5
1.6
1.4
1.0
1.0
1.0

III
III
III
III
III
III
II
III
II
II
II
II
I
I
I

5.30
5.97
6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
17.06
19.21
21.95
24.33
27.41

1010
1046
1051
1046
1040
1031
1019
1015
999
981
947
914
860
806
720

1483
1555
1589
1661
1730
1811
1886
1904
1985
2025
2025
2025
2025
2025
2025

SK 92372 - 90L/4
SK 92372 - 90LH/4

66

90

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

67

GEARMOTORS

Motor
Power

2.0, 3.0 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

2.0

342
304
191
170
151
131
118
103
63
55
49
44
39
35

368
414
661
742
836
959
1068
1220
2014
2269
2592
2831
3189
3644

3.4
3.4
3.0
2.9
2.9
2.8
2.7
2.7
1.4
1.3
1.3
1.0
0.9
0.9

III
III
III
III
III
III
III
III
II
I
I
I
*
*

4.85
5.46
8.71
9.78
11.02
12.64
14.08
16.08
26.55
29.91
34.17
37.32
42.04
48.03

1296
1343
1379
1375
1370
1361
1352
1341
1242
1197
1130
1071
965
790

1854
1953
2300
2394
2516
2626
2700
2700
2700
2700
2700
2700
2700
2700

SK 92672 - 90L/4
SK 92672 - 90LH/4

103

96

306
272
153
134
119
106
93
58
52
45
41
36
32

412
464
825
943
1055
1183
1353
2158
2431
2777
3093
3484
3981

3.4
3.4
3.0
3.0
2.9
2.7
2.7
2.5
2.3
2.1
1.3
1.3
1.3

III
III
III
III
III
III
III
III
III
III
I
I
I

5.43
6.11
10.88
12.43
13.91
15.60
17.83
28.44
32.04
36.61
40.77
45.93
52.48

1332
1379
1638
1703
1757
1814
1827
1773
1748
1712
1674
1620
1537

1973
2075
2567
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700

SK 92772 - 90L/4
SK 92772 - 90LH/4

118

102

322
286
263
233
206
180
157
150
131
100
89

588
663
721
813
921
1052
1204
1265
1445
1894
2133

2.2
2.1
2.0
1.8
1.7
1.5
1.3
1.4
1.2
1.1
1.0

III
III
III
II
II
II
I
II
I
I
I

5.30
5.97
6.49
7.32
8.29
9.47
10.84
11.39
13.01
17.06
19.21

968
997
1017
1022
1008
990
965
954
916
790
698

1366
1422
1447
1510
1555
1620
1661
1670
1721
1744
1780

SK 92372 - 100L/4
SK 92372 - 100LH/4

75

90

3.0

(AGMA Class I = fB 1.0 - 1.39

68

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

www.nord.com

3.0, 5.0 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

3.0

352
312
288
251
221
196
174
155
135
121
106
94
84
73
64
57
50

539
606
657
753
858
967
1086
1224
1404
1563
1785
2008
2262
2585
2948
3321
3794

2.3
2.3
3.4
3.2
3.1
2.9
2.6
2.4
2.1
1.9
1.8
1.4
1.3
1.3
1.0
0.9
0.9

III
III
III
III
III
III
III
III
III
II
II
II
I
I
I
*
*

4.85
5.46
5.92
6.78
7.73
8.71
9.78
11.02
12.64
14.08
16.08
18.08
20.37
23.28
26.55
29.91
34.17

1253
1301
1328
1375
1368
1361
1352
1341
1323
1305
1276
1242
1199
1132
1040
920
716

1762
1836
1879
1971
2052
2129
2205
2302
2394
2464
2619
2592
2682
2700
2700
2700
2700

SK 92672 - 100L/4
SK 92672 - 100LH/4

111

96

314
279
266
224
199
177
157
137
123
109
96
86
77
67
60
53
47

603
678
712
844
949
1069
1208
1380
1545
1732
1980
2191
2467
2819
3158
3558
4065

2.3
2.3
3.4
3.2
3.1
3.1
2.9
2.9
2.8
2.4
2.4
2.4
2.2
2.0
1.7
1.6
1.4

III
III
III
III
III
III
III
III
III
III
III
III
III
III
II
II
II

5.43
6.11
6.41
7.60
8.55
9.63
10.88
12.43
13.91
15.60
17.83
19.73
22.22
25.39
28.44
32.04
36.61

1294
1341
1355
1424
1469
1519
1571
1627
1676
1717
1775
1771
1744
1708
1665
1609
1521

1881
1971
1996
2117
2210
2302
2396
2516
2597
2678
2700
2700
2700
2700
2700
2700
2700

SK 92772 - 100L/4
SK 92772 - 100LH/4

127

102

325
289
266
236
208
182
159
151

968
1091
1186
1338
1515
1731
1981
2082

1.3
1.3
1.2
1.1
1.0
0.9
0.8
0.8

I
I
I
I
I
*
*
*

5.30
5.97
6.49
7.32
8.29
9.47
10.84
11.39

891
911
925
938
900
842
758
718

1159
1195
1195
1231
1242
1258
1258
1231

SK 92372 - 100LA/4
SK 92372 - 112MH/4

82

90

5.0

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

69

GEARMOTORS

Motor
Power

5.0 hp
Gearmotors
Motor
Power

Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

GEARMOTORS

[hp]

[rpm]

[Ib-in]

5.0

356
316
291
254
223
198
176
157
136
123
107
95
85
74

886
998
1082
1239
1413
1592
1787
2014
2310
2573
2939
3304
3723
4255

1.4
1.4
2.1
2.0
1.9
1.8
1.6
1.5
1.3
1.2
1.1
0.9
0.8
0.8

II
II
III
III
II
II
II
II
I
I
I
*
*
*

4.85
5.46
5.92
6.78
7.73
8.71
9.78
11.02
12.64
14.08
16.08
18.08
20.37
23.28

1190
1229
1249
1289
1321
1301
1276
1242
1188
1134
1042
927
752
380

1593
1658
1679
1744
1791
1836
1872
1940
1978
1996
2140
1971
2012
2142

SK 92672 - 100LA/4
SK 92672 - 112MH/4

118

96

318
282
269
227
202
179
159
139
124
111
97
87
78
68
61
54
47

992
1117
1171
1389
1563
1760
1988
2272
2542
2851
3258
3606
4061
4640
5198
5855
6691

1.4
1.4
2.1
2.0
1.9
1.9
1.8
1.8
1.7
1.5
1.5
1.5
1.4
1.2
1.0
1.0
0.9

II
II
III
III
II
II
II
II
II
II
II
II
II
I
I
I
*

5.43
6.11
6.41
7.60
8.55
9.63
10.88
12.43
13.91
15.60
17.83
19.73
22.22
25.39
28.44
32.04
36.61

1233
1276
1289
1341
1382
1418
1456
1499
1528
1555
1589
1600
1523
1402
1258
1037
590

1733
1802
1823
1913
1973
2052
2115
2180
2230
2259
2318
2318
2345
2390
2318
2318
2300

SK 92772 - 100LA/4
SK 92772 - 112MH/4

134

102

(AGMA Class I = fB 1.0 - 1.39

70

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

www.nord.com

7.5 hp
Gearmotors
Output
Speed

Output
Torque

Service
Factor

Pn

n2

Ta

fB

AGMA
Class

Gear
Ratio
itot

Standard Bearings

Model
Type

Weight Dim.
Page

FR

FA

OHL

Thrust

lb

[Ib]

[Ib]

[lb]

[hp]

[rpm]

[Ib-in]

7.5

358
318
293
256
224
199
177
157
137
123

1321
1487
1612
1846
2105
2372
2663
3001
3442
3834

1.8
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8

II
II
II
II
I
I
I
I
*
*

4.85
5.46
5.92
6.78
7.73
8.71
9.78
11.02
12.64
14.08

1116
1143
1159
1184
1206
1177
1114
1024
875
695

1395
1445
1440
1467
1472
1483
1469
1501
1472
1440

SK 92672 - 132S/4
SK 92672 - 132SH/4

169

96

361
320
284
271
228
203
180
159
140
125
111
97
88
78
68

1310
1479
1664
1745
2070
2328
2622
2963
3385
3788
4248
4855
5373
6051
6914

2.8
2.5
2.2
2.3
2.0
1.9
1.7
1.5
1.3
1.3
1.0
1.0
1.0
0.9
0.8

III
III
III
III
III
II
II
II
I
I
I
I
I
*
*

4.81
5.43
6.11
6.41
7.60
8.55
9.63
10.88
12.43
13.91
15.60
17.83
19.73
22.22
25.39

1132
1166
1195
1202
1242
1271
1294
1314
1334
1348
1350
1350
1206
956
367

1512
1559
1607
1613
1665
1694
1733
1762
1782
1784
1762
1744
1658
1627
1559

SK 92772 - 132S/4
SK 92772 - 132SH/4

184

102

(AGMA Class I = fB 1.0 - 1.39

www.nord.com

II = fB 1.4 - 1.99

III = fB 2.0

* = fB < 1.0)

(Model Type in blue is an Energy Efficient motor)

G1142 - Subject to Change Without Notice

71

GEARMOTORS

Motor
Power

Notes

NOTES

72

G1142 - Subject to Change Without Notice

www.nord.com

92 Series Reducers
& Combinations
Speed
Reducer
Selections
SK92072
SK92172
SK92372
SK92672
SK92772

DRIVESYSTEMS

www.nord.com
Model
Type

Gear
Ratio
itot

Output
Speed

Output
Torque*

n2

T2 max

1750 rpm

SK 92072

17.42
19.22
21.32
23.79
26.77
30.93
34.80
38.02
42.18
43.40
47.95

[rpm]

[Ib-in]

100
91
82
74
65
57
50
46
41
40
36

3806
3806
3806
3806
3806
3894
3894
3983
3983
3983
3983

73

SK 92072, SK 92172 NEMA-C + W


Ratings & Combinations
Model Type

Gear
Ratio

Output
Speed

itot

Output
Torque

Maximum input power

Input
Shaft

NEMA C-Face*
Available Combinations

n2

T2 max

[rpm]

[Ib-in]

[hp]

[hp]

[hp]

[hp]

56C

140TC

3.85
5.24
5.79
6.44
7.87
8.99
9.68
11.06
13.55
17.56
20.37
23.28
26.39
30.15
34.73
39.67
47.83
54.65

455
334
302
272
222
195
181
158
129
100
86
75
66
58
50
44
37
32

708
708
708
752
797
797
797
797
664
531
797
797
797
620
664
708
398
443

2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
1.36
0.84
1.09
0.95
0.83
0.57
0.53
0.49
0.23
0.22

1.32
1.32
1.32
1.32
1.32
1.32
1.32
1.32
0.90
0.56
0.72
0.63
0.55
0.38
0.35
0.33
0.15
0.15

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.68
0.42
0.54
0.47
0.42
0.29
0.26
0.25
0.12
0.11

0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.45
0.28
0.36
0.31
0.28
0.19
0.17
0.16
0.08
0.07

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X

SK 92172

4.10
4.77
5.33
6.04
7.04
8.01
9.07
10.37
11.81
13.49
15.61
18.79
22.78
26.03
28.24
32.27
36.11
41.26
46.90
53.59
63.29
72.31

427
367
328
290
249
218
193
169
148
130
112
93
77
67
62
54
48
42
37
33
28
24

664
708
752
797
841
885
929
974
1018
1062
1062
752
1062
1062
1062
1062
885
1018
664
797
443
487

2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
1.89
1.11
1.30
1.13
1.04
0.91
0.67
0.68
0.39
0.42
0.20
0.19

1.32
1.32
1.32
1.32
1.32
1.32
1.32
1.32
1.32
1.32
1.25
0.73
0.86
0.75
0.69
0.60
0.44
0.45
0.26
0.28
0.13
0.12

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.94
0.56
0.65
0.56
0.52
0.45
0.34
0.34
0.19
0.21
0.10
0.09

0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.62
0.37
0.43
0.37
0.34
0.30
0.22
0.22
0.13
0.14
0.06
0.06

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

1 hp

2 hp

W + NEMA

SK 92072

Based upon 1750 rpm

1750 rpm 1150 rpm 875 rpm 580 rpm

Input Speed

Input Speed

180TC 210TC 250TC

5 hp

10 hp

20 hp

C-face Adapter Maximum Input Power *

The maximum input power limit shown is the largest motor power typically combined with the gear unit. The Italicized power values
shown are not the mechanical limit and often may be increased through discussion with our sales or engineering department.

* The NEMA C-face power limit must also be considered when selecting a reducer. The C-face Adapters Maximum Input Power values
are displayed under the Available Combinations and based on a 1750 rpm motor.

lb

56C

140TC

SK 92072

15

24

24

SK 92172

26

35

35

74

G1142 - Subject to Change Without Notice

www.nord.com

SK 92372, SK 92672 NEMA-C + W


Ratings & Combinations
Gear
Ratio

Output
Speed

SK 92672

Maximum input power

Input
Shaft

NEMA C-Face*
Available Combinations

n2

T2 max

[rpm]

[Ib-in]

[hp]

[hp]

[hp]

[hp]

56C

140TC

5.30
5.97
6.49
7.32
8.29
9.47
10.84
11.39
13.01
14.65
17.06
19.21
21.95
24.33
27.41
31.32
33.80
38.62
43.52
49.73
55.00
62.85

330
293
270
239
211
185
161
154
135
119
103
91
80
72
64
56
52
45
40
35
32
28

1283
1372
1416
1460
1549
1549
1593
1726
1726
1682
2036
2036
1726
1859
2036
1682
1637
1682
1328
1505
974
1106

6.72
6.38
6.07
5.54
5.19
4.55
4.07
4.22
3.70
3.17
3.33
2.94
2.19
2.12
2.07
1.49
1.35
1.20
0.84
0.84
0.49
0.49

4.43
4.21
4.00
3.65
3.42
3.00
2.69
2.78
2.44
2.10
2.20
1.94
1.45
1.40
1.36
0.99
0.89
0.79
0.56
0.55
0.33
0.32

3.36
3.19
3.03
2.77
2.59
2.27
2.03
2.11
1.85
1.59
1.66
1.47
1.10
1.06
1.03
0.75
0.68
0.60
0.42
0.42
0.25
0.25

2.22
2.10
2.00
1.83
1.71
1.50
1.34
1.39
1.22
1.05
1.10
0.97
0.72
0.70
0.68
0.49
0.45
0.40
0.28
0.28
0.16
0.16

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

4.85
5.46
5.92
6.78
7.73
8.71
9.78
11.02
12.64
14.08
16.08
18.08
20.37
23.28
26.55
29.91
34.17
37.32
42.04
48.03
51.86
59.25

361
321
296
258
226
201
179
159
138
124
109
97
86
75
66
59
51
47
42
36
34
30

2345
2345
2478
2611
2744
2832
2832
2965
3009
3009
3275
2832
3009
3275
2921
3009
3363
2921
3009
3319
3053
3319

7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.48
6.59
5.92
5.66
4.36
4.11
3.90
3.06
2.82
2.72
2.18
2.01
1.90
1.65
1.58

4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.94
4.35
3.91
3.74
2.88
2.71
2.57
2.02
1.86
1.80
1.44
1.32
1.25
1.09
1.04

3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.74
3.29
2.96
2.83
2.18
2.05
1.95
1.53
1.41
1.36
1.09
1.00
0.95
0.82
0.79

2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.47
2.17
1.95
1.87
1.44
1.35
1.29
1.01
0.93
0.90
0.72
0.66
0.63
0.54
0.52

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X

X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

1 hp

2 hp

5 hp

10 hp

itot

SK 92372

Output
Torque*

Based upon 1750 rpm

1750 rpm 1150 rpm 875 rpm 580 rpm

Input Speed

Input Speed

180TC 210TC 250TC

X
X
X

W + NEMA

Model Type

20 hp

C-face Adapter Maximum Input Power *

The maximum input power limit shown is the largest motor power typically combined with the gear unit. The Italicized power values
shown are not the mechanical limit and often may be increased through discussion with our sales or engineering department.

* The NEMA C-face power limit must also be considered when selecting a reducer. The C-face Adapters Maximum Input Power values
are displayed under the Available Combinations and based on a 1750 rpm motor.

lb

56C

140TC

180TC

210TC

SK 92372

40

49

49

60

SK 92672

79

86

86

97

112

www.nord.com

G1142 - Subject to Change Without Notice

75

SK 92772 NEMA-C + W
Ratings & Combinations
Model Type

Gear
Ratio

Output
Speed

itot

SK 92772

W + NEMA

4.81
5.43
6.11
6.41
7.60
8.55
9.63
10.88
12.43
13.91
15.60
17.83
19.73
22.22
25.39
28.44
32.04
36.61
40.77
45.93
52.48
56.02
64.01

Output
Torque

Maximum input power

Input
Shaft

NEMA C-Face*
Available Combinations

n2

T2 max

[rpm]

[Ib-in]

[hp]

[hp]

[hp]

[hp]

364
322
286
273
230
205
182
161
141
126
112
98
89
79
69
62
55
48
43
38
33
31
27

3629
3761
3717
3983
4204
4381
4381
4558
4558
4735
5177
5177
5310
5487
5753
5310
5576
5841
3983
4469
5089
3540
4071

7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
6.88
6.30
5.22
4.87
4.45
2.72
2.69
2.66
1.74
1.74

4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.95
4.54
4.16
3.45
3.21
2.94
1.79
1.78
1.76
1.15
1.15

3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.44
3.15
2.61
2.43
2.22
1.36
1.35
1.33
0.87
0.87

2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.48
2.47
2.27
2.08
1.72
1.61
1.47
0.90
0.89
0.88
0.57
0.58

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X

1 hp

2 hp

Based upon 1750 rpm

1750 rpm 1150 rpm 875 rpm 580 rpm

Input Speed

Input Speed

56C

140TC

180TC 210TC 250TC

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X

5 hp

10 hp

20 hp

C-face Adapter Maximum Input Power *

The maximum input power limit shown is the largest motor power typically combined with the gear unit. The Italicized power values
shown are not the mechanical limit and often may be increased through discussion with our sales or engineering department.

* The NEMA C-face power limit must also be considered when selecting a reducer. The C-face Adapters Maximum Input Power values
are displayed under the Available Combinations and based on a 1750 rpm motor.

lb

SK 92772

76

56C

140TC

180TC

210TC

250TC

99

101

101

112

128

128

G1142 - Subject to Change Without Notice

www.nord.com

92 Series Helical-bevel
Dimensions
AB(BR)

C(BR)

AB

3.78

7.42
0.12

2.20

1.50

0.39
3

3
16 x 16
1 -20
4

x114

1.76

1.03
1.38

1.03

3.87
4.06

+0.0000

2.01

0.750 - 0.0005

0.35
3.54

0.1875

2.20

0.95

1.02

1.38
2.76
3.71

AB(BR)

C(BR)

AB

3.78

7.42

2.17

0.12

2.20

1.50

0.39
3

3
16 x 16
1 -20
4

x114

1.76

1.03
1.38

1.03

3.87
4.06

+0.0000

2.01

0.750 - 0.0005

0.35
3.54

0.1875

2.20
0.63

2.76

6.06

0.83

1.20

3.78

FP

0.63

2.76

6.06

0.83

FP

2.17

1.20

3.78

0.39

Gearmotor
Reducers C-Face
Options
Shafts

0.95

1.02

1.38

0.39

Dimensions

2.76
3.71

DRIVESYSTEMS

www.nord.com
0.20

3.58

5.47
CC

1.69

FV

4.57

0.63

TAP
KEY

0.1875

FU

1.38

7.087

4.53

0.16

9.84 (250)

12.09

FW

0.98

0.98

0.84

+0.0010

0.75 -0.0000

8.66

77

SK 92072 + Motor
SK 92072

AB(BR)

C(BR)

AB
3.78

3.78

7.42

2.17

0.12

2.20

1.50

0.39
3

x3

1
16 x1 4

Dim
ensions in Inches

DIMENSIONS

4.06

1.76

1.20

1.03
1.03

2.76

1.38

0.95

1.02

1.38

0.39

2.01

+0.0000

0.35
3.54

0.750 - 0.0005

0.63

0.1875

2.20

3.87

6.06

0.83

FP

16
1 -20
4

2.76
3.71
C(BR)

SK 92072AX

AB(BR)

AB
0.12

2.17 2.17

7.42
0.12

2.20

1.02

1.38

4.06

0.39

0.95
3.54

FP

1.20

1.03
1.03

1.38

3.87

2.76

2.20
0.63

2.76
3.71

SK 92072AX 63S

SK 92072AX
4.57
0.1875

1.38

ALTERNATE SHAFTS SEE PAGES 112 - 116

6.06

0.39

0.98

0.98

0.84

+0.0010

0.75 -0.0000

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

80LH

90SH/LH

5.59

5.79

AB (BR)

4.84

5.24

5.59

5.79

15.01

15.86

16.73

18.26

C (BR)

17.21

18.15

19.25

21.22

FP

5.09

5.72

6.43

7.19

78

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92072 + NEMA
SK 92072
C1
3.78

7.42
0.12

U1

Y1
AK1

1.03
1.38

1.03

2.76

+0.0000

0.95

1.02

1.38

BF1

AJ1
ensions in Inches

1.76

0.750 - 0.0005

4.06

0.1875

2.20

3.87

6.06

0.83

0.35

UY1

BD1

3
16 x 16
1 -20
4

2.01

BB1

x114

3.54

GA1

0.39

2.76
3.71

Dim

SK 92072 56C
C1
7.42

CC

2.17 2.17

0.12

0.39

BB1

UY1

1.02

1.38

4.06

AK1

BF1

0.39

0.95
3.54

BD1

1.20

1.03
1.03

2.76

0.63

1.38

2.20

3.87

6.06

Y1

0.12

GA1

ALTERNATE SHAFTS SEE PAGES 112 - 116

2.20

U1

SK 92072AX

AJ1

2.76
3.71

SK 92072AX 56C

SK 92072AX
0.1875

1.38

4.57

0.98

0.98

0.84

+0.0010

0.75 -0.0000

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

11.71

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

11.71

4.29

www.nord.com

DIMENSIONS

1.50

0.63

CC

2.20

0.39

2.17

1.20

3.78

G1142 Subject to Change Without Notice

79

SK 92072 + Motor
SK 92072VF

AB(BR)

C(BR)

AB

4.67
2.17

7.52

3.17

1.50

2.30
3

x3

1
16 x1 4

Dim
ensions in Inches

DIMENSIONS

SK 92072AF

1.20

FP

1.50

+0.0000

0.12
0.39

0.750 - 0.0005

0.1875

3.740

2.20

0.83

5.51 (140)

6.06

16
1 -20
4

4.53

0.35

AB(BR)
C(BR)

AB
3.17

2.17

0.12

C
0.89

7.52

FP
1.20

3.740

5.51 (140)

2.20

0.12
0.39

4.53

SK 92072AF

0.35

SK 92072AFS
5.67
0.1875

1.38

4.57
1.38

ALTERNATE SHAFTS SEE PAGES 112 - 116

6.06

2.30

0.98

0.98

1.22

0.84

+0.0010

+0.0008

0.75 -0.0000

1.00 -0.0000

+0.0000

1.00 +0.0005

Motor Dimensions
Standard efficiency

63S/L

71S/L

Energy efficiency

80S/L

90S/L

80LH

90SH/LH
5.79

AB

4.51

4.86

5.59

AB (BR)

4.84

5.24

5.59

5.79

15.11

15.96

16.83

18.36

C (BR)

17.31

18.24

19.35

21.31

FP

5.09

5.72

6.43

7.19

80

1.26

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92072 + NEMA
SK 92072VF

C1
7.52
4.67

2.30

GA1

1.50

BB1
x3

Y1

0.12

AK1

BF1

Dim

SK 92072AF

C1
7.52

2.17

3.17

CC

2.30

GA1
BB1

UY1

AK1
1.20

0.12
0.39

BF1

AJ1

0.35

4.53

SK 92072AF

BD1

5.51 (140)

2.20

3.740

6.06

Y1

0.89

ALTERNATE SHAFTS SEE PAGES 112 - 116

0.12

AJ1

0.35

4.53

ensions in Inches

1.50

BD1

1.20

+0.0000

0.750 - 0.0005

0.1875

3.740

2.20

0.83

5.51 (140)

6.06

16
1 -20
4

0.39

UY1

1
16 x1 4

DIMENSIONS

U1

3.17

U1

2.17

CC

SK 92072AFS
5.67
1.38

0.1875

1.38

4.57

0.98

0.98

1.22

0.84

+0.0010

1.26
+0.0008

0.75 -0.0000

1.00 -0.0000

+0.0000

1.00 +0.0005

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

11.81

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

11.81

4.29

www.nord.com

G1142 Subject to Change Without Notice

81

SK 92072 + Motor
AB(BR)

C(BR)

AB
3.78

3.78

7.52

4.06

2.30

0.83

+0.0000

0.10

Dim
ensions in Inches

DIMENSIONS

0.750 - 0.0005

0.1875

2.20

0.12
2.07

x114

1.20

3
16 x 16
1 -20
4

3.98

2.756

6.06

1.50

SK 92072AZ

FP

SK 92072VZ

0.236x0.39
M8x0.16

3.35

AB(BR)

C(BR)

AB

4.06

7.52

0.10

0.12
2.07 2.07

FP

1.20

3.98

2.20
0.12

0.236x0.39

0.10

3.35

SK 92072AZ

M8x0.16

SK 92072AZS
5.67
0.1875

1.38

4.57
1.38

ALTERNATE SHAFTS SEE PAGES 112 - 116

2.756

6.06

2.30

0.98

0.98

1.22

0.84

+0.0010

+0.0008

0.75 -0.0000

1.00 -0.0000

+0.0000

1.00 +0.0005

Motor Dimensions
Standard efficiency

63S/L

71S/L

Energy efficiency

80S/L

90S/L

80LH

90SH/LH
5.79

AB

4.51

4.86

5.59

AB (BR)

4.84

5.24

5.59

5.79

15.11

15.96

16.83

18.36

C (BR)

17.31

18.24

19.35

21.31

FP

5.09

5.72

6.43

7.19

82

1.26

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92072 + Nema
SK 92072VZ

C1
3.78

7.52

4.06

CC

2.30

GA1

1.50

BB1
x3

UY1

1
16 x1 4

AK1

1.20
+0.0000

0.10

0.236x0.39

BF1

AJ1

M8x0.16

3.35

SK 92072AZ

ensions in Inches

0.12
2.07

0.750 - 0.0005

0.1875

3.98

2.20

2.756

6.06

0.83

BD1

Y1

16
1 -20
4

Dim

C1
7.52

CC
GA1
UY1

0.10

3.35

SK 9207AZ

BF1

ALTERNATE SHAFTS SEE PAGES 112 - 116

2.07 2.07

AK1
0.236x0.39

0.12

0.10

BD1

1.20

3.98

2.20

2.756

6.06

Y1

BB1

U1

2.30
4.06

0.12

AJ1

M8x0.16

SK 92072AZS
5.67
1.38

0.1875

1.38

4.57

0.98

0.98

1.22

0.84

+0.0010

1.26
+0.0008

0.75 -0.0000

1.00 -0.0000

+0.0000

1.00 +0.0005

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

11.81

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

11.81

4.29

www.nord.com

DIMENSIONS

U1

3.78

G1142 Subject to Change Without Notice

83

SK 92172 + Motor
AB(BR)

C(BR)

AB
4.14

6.79
0.16
1.50

0.59
3
16 x 16
1 -20
4

x1

1.46

4.73
+0.0000

2.17

4.72

Dim
ensions in Inches

DIMENSIONS

0.750 - 0.0005

0.1875

2.48

0.35

3.94

3.54

6.59

1.13

0.83

1.78

FP

0.83

1.08

2.48

1.56

2.48

1.18

4.14

1.57

1.58

1.46

0.59

SK 92172

3.54

5.31

4.92
C(BR)

SK 92172AX

AB(BR)

AB
0.16

2.48

6.79

2.48

0.16

1.08

2.48

1.58

1.46

4.72

3.54

5.31

4.92

0.59

1.57

3.94

FP

1.56

1.18

1.46

3.54

2.48

0.35

0.83

SK 92172AX
5.28
0.1875

1.38

ALTERNATE SHAFTS SEE PAGES 112 - 116

4.73

6.59

1.13

0.59

1.18

1.18

0.84

+0.0010

0.75 -0.0000

Motor Dimensions
Standard efficiency

63S/L

71S/L

Energy efficiency

80S/L

90S/L

80LH

90SH/LH
5.79

AB

4.51

4.86

5.59

AB (BR)

4.84

5.24

5.59

5.79

15.46

16.31

17.18

18.72

C (BR)

17.67

18.60

19.70

21.67

FP

5.09

5.72

6.43

7.19

84

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92172 + NEMA
SK 92172

C1
4.14

6.79
0.16

2.48

1.50

U1

Y1
1.58

1.46
3.54

5.31

4.92

6.79

Dim

C1
1.08

CC

2.48
0.16

0.59

BB1

UY1
U1

2.48

1.46

3.94

AK1

BD1

1.56

BF1

1.57

1.58

1.46

4.72

3.54

5.31

4.92

AJ1

0.59

0.35

0.83

1.18

4.73

2.48

3.54

6.59

1.13

Y1

2.48

GA1

ALTERNATE SHAFTS SEE PAGES 112 - 116

SK 92172AX
0.16

BD1

AK1

1.13
1.46

1.57

AJ1

SK 92172AX
0.1875

1.38

5.28

1.18

1.18

0.84

+0.0010

0.75 -0.0000

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

12.17

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

12.17

4.29

www.nord.com

DIMENSIONS

1.78

BF1

ensions in Inches

4.72

3.54

+0.0000

0.750 - 0.0005

0.1875

2.48

4.73

6.59

0.35

UY1

x1

0.83

2.17

BB1

0.59

3
16 x 16
1 -20
4

3.94

GA1

0.59
3

0.83

CC

1.56

2.48

1.08

1.18

4.14

G1142 Subject to Change Without Notice

85

SK 92172 + Motor
SK 92172VF

AB(BR)

C(BR)

AB

5.12
1.50

1.50

FP

0.83

Dim
ensions in Inches

DIMENSIONS

5.31

1.56

0.14

x1

+0.0000

2.41

4.331

6.30 (160)

6.52

3
16 x 16
1 -20
4

0.47

1.08

2.52
3

0.750 - 0.0005

3.62

0.1875

2.56

6.83

0.35

5.12

AB(BR)

SK 92172AF

C(BR)

AB
0.16

2.56

3.62

C
0.91

6.83

1.08

FP
1.56

4.331

6.30 (160)

2.41

0.14
0.47

0.35

5.12

5.31

SK 92172AF

SK 92172AFS
6.69

0.250

1.57

5.43
1.57

ALTERNATE SHAFTS SEE PAGES 112 - 116

6.52

2.52

1.18

1.18

1.09

1.22

+0.0008

+0.0010

1.00 -0.0000

1.00 -0.0000

+0.0000

1.00 -0.0005

Motor Dimensions
Standard efficiency

63S/L

71S/L

Energy efficiency

80S/L

90S/L

80LH

90SH/LH
5.79

AB

4.51

4.86

5.59

AB (BR)

4.84

5.24

5.59

5.79

15.50

16.35

17.22

18.76

C (BR)

17.70

18.64

19.74

21.71

FP

5.09

5.72

6.43

7.19

86

1.38

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92172 + NEMA
SK 92172VF

C1
6.83
5.12

GA1
BB1

AK1

U1

Y1
0.35

5.12

SK 92172AF

CC

2.52

GA1
BB1

UY1

AK1

BD1

BF1

1.56

4.331

2.41

6.30 (140)

6.52

Y1

0.91

0.14
0.47

ALTERNATE SHAFTS SEE PAGES 112 - 116

3.62

1.08

U1

2.56

Dim

C1
6.83

AJ1

0.35

5.12

5.31

SK 92172AF

SK 92172AFS
6.69
1.57

0.250

1.57

5.43

1.18

1.09

1.18

1.22

1.38
+0.0008

+0.0010

1.00 -0.0000

1.00 -0.0000

+0.0000

1.00 -0.0005

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

12.20

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

12.20

4.29

www.nord.com

DIMENSIONS

5.31

AJ1

ensions in Inches

1.50

BF1

1.56

0.1875

4.331

6.30 (140)

2.41

0.83

0.14
0.47

UY1

x1

BD1

3
16 x 16
1 -20
4

6.52

0.16

CC

1.50

+0.0000

3.62

0.750 - 0.0005

2.56

1.08

2.52

G1142 Subject to Change Without Notice

87

SK 92172 + Motor
SK 92172VZ

AB(BR)

C(BR)

AB
4.22

C
6.83

4.22
1.50

1.08

2.52
3

3
16 x 16
1 -20
4

x1

0.12

Dim
ensions in Inches

DIMENSIONS

5.31

FP
1.56

+0.0000

0.16
2.44

0.750 - 0.0005

0.1875

4.72

2.41

3.150

6.52

0.83

M6x0.39
3.94

0.236x0.47

SK 92172AZ

C(BR)
AB(BR)

AB

6.83

1.08

0.12

FP
1.56

4.72

3.150

2.41
0.16

0.16
2.44 2.44

M6x0.39

0.12

5.31

0.236x0.47

3.94

SK 92172AZ

SK 92172AZS
6.69

0.250

1.57

5.43
1.57

ALTERNATE SHAFTS SEE PAGES 112 - 116

6.52

2.52

1.18

1.18

1.09

1.22

+0.0008

+0.0010

1.00 -0.0000

1.00 -0.0000

+0.0000

1.00 -0.0005

Motor Dimensions
Standard efficiency

63S/L

71S/L

80S/L

90S/L

AB

4.51

4.86

80LH

90SH/LH

5.59

AB (BR)

4.84

5.79

5.24

5.59

5.79

C
C (BR)

15.50

16.35

17.22

18.76

17.70

18.64

19.74

FP

21.71

5.09

5.72

6.43

7.19

Energy efficiency

88

1.38

For Other Connection


Possibilities please see

108 & 109

G1142 Subject to Change Without Notice

www.nord.com

SK 92172 + NEMA
SK 92172VZ

C1
6.83
4.22

CC

2.52

GA1

1.50

BB1

M6x0.39
3.94

0.236x0.47

6.83

Dim

C1
1.08

CC

2.52

GA1
UY1

2.44 2.44

BD1

AK1

0.16

0.12

BF1

1.56

0.16

4.72

2.41

3.150

6.52

Y1

U1

BB1

0.12

ALTERNATE SHAFTS SEE PAGES 112 - 116

SK 92172AZ

AJ1

M6x0.39

5.31

3.94

SK 9217AZ

0.236x0.47

SK 92172AZS
6.69
1.57

0.250

1.57

5.43

1.18

1.18

1.09

1.22

1.38
+0.0008

+0.0010

1.00 -0.0000

1.00 -0.0000

+0.0000

1.00 -0.0005

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

12.20

4.29

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

12.20

4.29

www.nord.com

DIMENSIONS

5.31

AJ1

ensions in Inches

0.12

BF1

1.56

+0.0000

0.16

0.750 - 0.0005

0.1875

4.72

2.41

3.150

6.52

0.83

2.44

U1

x1

Y1

3
16 x 16
1 -20
4

AK1

UY1

BD1

4.22

1.08

G1142 Subject to Change Without Notice

89

SK 92372 + Motor
AB (BR)

C (BR)

AB

5.35

8.43
0.24

2.13

3.15
1
4
3

x 14 x 1 5 8
8 -16

0.71

0.35
4.72

2.99

5.67

2.52

1.34
1.36

4.33

1.97

5.62

1.77

1.000

0.98

+0.0000
- 0.0005

3.15

0.25

7.83

1.11

FP

2.99

ZB

1.83

5.35

1.77

1.97

0.71

SK 92372

4.33

Dim

C (BR)

SK 92372AX

C
AB (BR)

8.43

AB
0.16

0.71

1.36

4.33

1.97

3.15

5.62

7.76

0.35

1.77

4.72

1.77

1.97

5.67

4.33
6.10

SK 92372AX

6.46
0.250

1.97

ALTERNATE SHAFTS SEE PAGES 112 - 116

0.98

FP

2.99

0.71

2.99

1.34

0.16

ZB

3.15

1.83

ensions in Inches

DIMENSIONS

6.10

1.97

1.97

1.30

+0.0010

1.1875 -0.0000

Motor Dimensions
Standard efficiency

63S/L

71S/L

80S/L

90S/L

100L

AB

4.51

4.86

80LH

90SH/LH

100LH

5.59

5.79

6.65

7.05

AB (BR)

4.84

7.05

5.24

5.59

5.79

6.77

7.17

N/A

C
C (BR)

16.80

17.65

18.52

20.65

21.87

22.62

23.61

19.00

19.94

21.04

23.60

25.47

26.32

N/A

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

ZB

0.79

0.79

0.79

1.38

1.38

1.38

1.38

Energy efficiency

90

112M
112MH

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92372 + NEMA
C1

SK 92372

8.43

CC

0.24

Y1
BD1

1.34
1.97

4.33

6.10

SK 92372AX

Dim

C1
8.43

ZB

CC

3.15
2.99

0.16

GA1

0.71

BB1

UY1
U1

2.99

1.97

BD1

AK1

1.83

1.36

0.35

BF1

1.77

4.72

1.77

1.97

5.67

AJ1

0.71

0.98

4.33

3.15

5.62

7.76

1.34

Y1

0.16

4.33
6.10

6.46
0.250

1.97

SK 92372AX

1.97
1.1875

1.97

1.30

+0.0010
-0.0000

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

13.50

4.29

0.79

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

13.50

4.29

0.79

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

15.09

5.28

1.38

www.nord.com

DIMENSIONS

4.33

G1142 Subject to Change Without Notice

91

ALTERNATE SHAFTS SEE PAGES 112 - 116

2.52

1.77

1.97

AJ1

ensions in Inches

5.67

BF1

1.77

1.000

0.35
2.99

5.62
+0.0000
- 0.0005

3.15

0.25

7.83

1.11

4.72

UY1

x 14 x 1 5 8
8 -16

AK1

1
4
3

BB1

0.71

2.13

GA1

0.71

1.83

2.99

0.98

ZB

3.15

U1

5.35

1.36

5.35

SK 92372 + Motor
AB (BR)

SK 92372VF

C (BR)

AB

6.85
3.07

8.35

4.72

2.13

ZB

3.09
1
4
3

x 14 x 1 5 8
8 -16

1.000

BB
GA

2.13

AJ

BF

C (BR)

3.07

4.72

8.35

3.07

AK

ZB

3.09

1.83

1.50

FP

0.16

7.68

ensions in Inches

AB

BD

Dim

DIMENSIONS

AB (BR)

SK 92372AF

FP

1.83
+0.0000
- 0.0005

0.25

AK
3.07

BD

7.68

1.11

BB
AJ

SK 92372AF

BF

SK 92372AFS
7.87
0.250

1.96

6.46
1.97

ALTERNATE SHAFTS SEE PAGES 112 - 116

GA

1.97
1.1875

1.30

1.97

1.24

+0.0010
-0.0000

1.42
+0.0009

1.1875 -0.0000

Mounting flange
BD (mm)

AJ

AK
+0.0005
- 0.0004

BB

BF

GA

6.30 (160)

5.12

0.14

0.35

0.47

7.87 (200)

6.50 5.118 - 0.0004 0.14

0.43

0.47

4.33

+0.0005

+0.0000

1.1875 -0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
112MH
7.05

7.05

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

16.72

17.57

18.44

20.57

21.79

22.54

23.53

C (BR)

18.93

19.86

20.96

23.52

25.39

26.24

N/A

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

ZB

0.79

0.79

0.79

1.38

1.38

1.38

1.38

92

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92372 + NEMA
C1

SK 92372VF

8.35

CC
GA1

3.09

BB1
x 14 x 15 8
8 -16

AK1

1.83

0.25

AK

BF1

+0.0000
- 0.0005

3.07

BD

7.68

1.11

2.13

AJ

AJ1

BF

ensions in Inches

GA

1.000

BB

C1
8.35

ZB

CC

3.09
3.07

GA1

4.72

Dim

SK 92372AF
0.16

UY1

Y1

1
4
3

U1

2.13

BD1

4.72

BB1

DIMENSIONS

6.85
3.07

ZB

UY1

BD1

AK1

1.83

AK
3.07

BD

7.68

Y1

U1

1.50

BF1

AJ1

GA

AJ

SK 92372AF

ALTERNATE SHAFTS SEE PAGES 112 - 116

BB
BF

SK 92372AFS
7.87
1.96

0.250

1.97

6.46

1.97
1.1875

1.30

1.97

1.24

+0.0010
-0.0000

1.42
+0.0009

1.1875 -0.0000

+0.0000

1.1875 -0.0006

Mounting flange
BD (mm)

AJ

AK
4.33

+0.0005
- 0.0004

BB

BF

GA

6.30 (160)

5.12

0.14

0.35

0.47

7.87 (200)

6.50 5.118 - 0.0004 0.14

0.43

0.47

+0.0005

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

13.43

4.29

0.79

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

13.43

4.29

0.79

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

15.01

5.28

1.38

www.nord.com

G1142 Subject to Change Without Notice

93

SK 92372 + Motor
SK 92372VZ

AB (BR)

5.44

AB

C (BR)

5.44

C
8.35

2.13
1
4
3

x 14 x 1 5 8
8 -16

ZB

3.09

M8x0.51

1.000

2.13
0.24
2.95

FP

1.83
+0.0000
- 0.0005

0.25

5.51

3.07

3.740

7.68

1.11

0.12

4.53

0.315x0.47

Dim
ensions in Inches

DIMENSIONS

SK 92372AZ

C (BR)
AB (BR)

AB

8.35

ZB

0.16
0.12

2.95

FP

1.83

5.51

0.16
2.95

M8x0.51

0.12

4.53

SK 92372AZ

0.315x0.47

SK 92372AZS
7.87
0.250

1.96

6.46
1.97

ALTERNATE SHAFTS SEE PAGES 112 - 116

3.07

3.740

7.68

3.09

1.97
1.1875

1.97

1.30

1.24

+0.0010
-0.0000

1.42

1.1875

+0.0009
-0.0000

+0.0000

1.1875 -0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
112MH
7.05

7.05

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

16.72

17.57

18.44

20.57

21.79

22.54

23.53

C (BR)

18.93

19.86

20.96

23.52

25.39

26.24

N/A

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

ZB

0.79

0.79

0.79

1.38

1.38

1.38

1.38

94

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92372 + NEMA
SK 92372VZ

C1
8.35
5.44

CC

3.09

GA1
BB1

AK1

1.83

0.25

BF1

+0.0000
- 0.0005

4.53

C1
8.35

ZB

CC

3.09

Dim

SK 92372AZ

GA1
UY1

BD1

AK1

1.83

BF1

0.16
0.12

5.51

3.07

3.740

7.68

Y1

U1

BB1

0.16
2.95

2.95

AJ1

M8x0.51

0.12

4.53

SK 92372AZ

0.315x0.47

SK 92372AZS
7.87
1.96

0.250

1.97

6.46

1.97
1.1875

1.97

1.30

1.24

+0.0010
-0.0000

1.1875

1.42
+0.0009
-0.0000

+0.0000

1.1875 -0.0006

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

13.43

4.29

0.79

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

13.43

4.29

0.79

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

15.01

5.28

1.38

www.nord.com

G1142 Subject to Change Without Notice

DIMENSIONS

0.315x0.47

95

ALTERNATE SHAFTS SEE PAGES 112 - 116

0.24
0.12

AJ1

M8x0.51

1.000

2.13

ensions in Inches

5.51

3.07

3.740

7.68

1.11

2.95

UY1

x 14 x 1 5 8
8 -16

Y1

1
4
3

U1

2.13

BD1

5.44

ZB

SK 92672 + Motor
AB (BR)

C (BR)

AB

6.10
0.16

3.94
1 x 1
4
4
1 -13
2

0.71

x 214

3.73

6.14

3.02

2.06

5.12

2.48

+0.0000

0.43
4.72

1.250 - 0.0005

0.25

3.94

6.51

10.31

1.36

FP

2.75

1.22

ZB

2.68

3.19

10.51

1.77

6.10

2.87

1.77

1.38

0.71

SK 92672

5.12

Dim
ensions in Inches

DIMENSIONS

7.48

8.01
C (BR)

AB (BR)

SK 92672AX

AB
0.16

3.19 3.19

10.51
0.16

ZB

3.94

1.77

1.38

6.14

0.71

2.87

4.72

FP

2.68

2.06
1.77

5.12

2.48

3.94

0.43

1.22

5.12
8.01

7.48

SK 92672AX
6.69
0.3125

2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

6.51

10.31

0.71

2.36

2.36

1.375

+0.0010
-0.0000

1.52

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
7.05

132S
112MH

132SH

7.05

8.03

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

7.91

18.61

19.46

20.33

22.42

23.64

24.70

25.70

28.32

C (BR)

20.81

21.75

22.85

25.37

27.24

28.41

N/A

32.54

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.38

96

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92672 + NEMA
SK 92672

C1
10.51
6.10
0.16

UY1
U1

Y1
AK1
1.77

1.38

AJ1

8.01

10.51

ZB

CC

3.94
3.19 3.19

0.16

GA1

0.71

BB1

UY1

AK1

BF1
1.77

1.38

6.14

AJ1

0.71

2.87

4.72

BD1

2.68

2.06
1.77

5.12

0.43

1.22

2.48

3.94

6.51

10.31

Y1

0.16

U1

SK 92672AX

Dim

C1

5.12
8.01

7.48

SK 92672AX

2.36

1.375

+0.0010
-0.0000

0.3125

2.17

6.69

2.36

1.52

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

15.31

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

15.31

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

19.14

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

19.14

7.25

1.38

www.nord.com

DIMENSIONS

5.12

7.48

G1142 Subject to Change Without Notice

97

ALTERNATE SHAFTS SEE PAGES 112 - 116

3.02

BF1

2.87

ensions in Inches

3.73

BD1

2.06

5.12

+0.0000

1.250 - 0.0005

0.25

2.48

6.51

10.31
3.94

0.43

6.14

BB1

x 214

0.71

1 x 1
4
4
1 -13
2

1.36

1.22

GA1

0.71

2.75

4.72

CC

2.68

3.19

ZB

3.94

1.77

6.10

SK 92672 + Motor
SK 92672VF

AB (BR)

C (BR)

AB

7.59
3.19

4.84

10.06
2.75

1 x 1
4
4
1 -13
2

ZB

3.48

x 214

FP

2.68

2.75

7.48

+0.0000

BB
GA

1.250 - 0.0005

0.25

BD

3.62

AK

10.00

1.36

BF
AJ

Dim

AB (BR)

C (BR)

AB
0.16

3.19

4.84

10.06
3.48

2.68

BD

3.62

AK

10.00

1.50

ZB

FP

ensions in Inches

DIMENSIONS

SK 92672AF

BF
AJ

7.48

SK 92672AF

SK 92672AFS
8.27

2.36

2.36

1.375

+0.0010
-0.0000

2.17

0.3125

6.69
2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

BB
GA

1.52

1.63

Mounting flange
BD (mm)

AJ

AK

6.30 (160) 5.12 4.331

+0.0005
- 0.0004
+0.0005

7.87 (200) 6.50 5.118 - 0.0004

BB

BF

GA

0.14

0.35

0.47

0.14

0.43

0.47

1.57

1.375

+0.0009
-0.0000

1.375

+0.0000
-0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
7.05

132S
112MH

132SH

7.05

8.03

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

7.91

18.16

19.01

19.88

21.96

23.19

24.25

25.24

27.87

C (BR)

20.36

21.30

22.40

24.92

26.79

27.95

N/A

32.08

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.38

98

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92672 + NEMA
C1

SK 92672VF

10.06

ZB

CC

3.48

GA1

7.59
x 214

GA

AK1

2.68

BF1

+0.0000

BB

1.250 - 0.0005

0.25

BD

3.62

AK

10.00

1.36

2.75

7.48

AJ1

BF
AJ

10.06

ZB

CC

3.48
0.16

3.19

GA1

4.84

BB1

Dim

SK 92672AF

ensions in Inches

C1

UY1

DIMENSIONS

1 x 1
4
4
1 -13
2

U1

2.75

Y1

4.84

UY1

BD1

3.19

BB1

AK1

BD1

2.68

AK
3.62

BD

10.00

Y1

U1

1.50

BF1

AJ1

BF

GA

ALTERNATE SHAFTS SEE PAGES 112 - 116

BB
AJ

7.48

SK 92672AF

SK 92672AFS
8.27

2.36

2.36

1.375

+0.0010
-0.0000

2.17

0.3125

2.17

6.69

1.52

1.63

1.57

1.375

+0.0009
-0.0000

1.375

+0.0000
-0.0006

Mounting flange
BD (mm)

AJ

AK

BB

BF

GA

6.30 (160) 5.12 4.331

+0.0005
- 0.0004

0.14

0.35

0.47

7.87 (200) 6.50 5.118

+0.0005
- 0.0004

0.14

0.43

0.47

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

14.86

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

14.86

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

18.69

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

18.69

7.25

1.38

www.nord.com

G1142 Subject to Change Without Notice

99

SK 92672 + Motor
SK 92672VZ
AB (BR)

C (BR)

AB

6.10

6.10

10.06

2.75

1 x 1
4
4
1 -13
2

ZB

3.48

214

FP

2.68
1.250 -0.0005

0.16
3.07

+0.0000

0.25

5.51

3.62

3.74

10.00

1.36

0.12

7.48

M8x0.51
4.53

0.315x0.47

Dim
ensions in Inches

DIMENSIONS

SK 92672AZ

C (BR)
AB (BR)

AB

10.06

ZB

0.16
0.12

0.16
3.07 3.07

FP
M8x0.51

0.12

4.53

0.315x0.47

7.48

SK 92672AZ

SK 92672AZS
8.27

2.36

2.36

1.375

+0.0010
-0.0000

2.17

0.3125

6.69
2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

3.62

2.68

10.00

3.48

1.52

1.63

1.57

1.375

+0.0009
-0.0000

1.375

+0.0000
-0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
7.05

132S
112MH

132SH

7.05

8.03

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

7.91

18.16

19.01

19.88

21.96

23.19

24.25

25.24

27.87

C (BR)

20.36

21.30

22.40

24.92

26.79

27.95

N/A

32.08

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.38

100

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92672 + NEMA
SK 92672VZ

C1
10.06

ZB

CC

3.48

GA1

6.10

BB1

AK1

2.68
+0.0000

4.53

0.315x0.47

C1
10.06

ZB

CC

en
Dim

SK 92672AZ
3.48

GA1
BB1

AK1

BD1

3.62

2.68

10.00

Y1

U1

UY1

BF1

0.16
0.12

0.16
3.07 3.07

AJ1

M8x0.51

0.12

4.53

0.315x0.47

7.48

SK 92672AZ

SK 92672AZS
8.27

2.36

2.36

1.375

+0.0010
-0.0000

2.17

0.3125

2.17

6.69

1.52

1.63

1.57

1.375

+0.0009
-0.0000

1.375

+0.0000
-0.0006

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

14.86

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

14.86

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

18.69

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

18.69

7.25

1.38

www.nord.com

DIMENSIONS

0.12

AJ1

M8x0.51

G1142 Subject to Change Without Notice

101

ALTERNATE SHAFTS SEE PAGES 112 - 116

3.07
7.48

BF1

1.250 - 0.0005

0.25

5.51

3.62

3.74

10.00

1.36

0.16

U1

UY1

214

sions in Inche
s

1 x 1
4
4
1 -13
2

Y1

2.75

BD1

6.10

SK 92772 + Motor
AB (BR)

C (BR)

AB

6.78

11.85
0.20

4.41
5
1

16

2
5

16

0.87

x2

-11

5.51

4.02

6.89

3.33

2.47
2.44

7.90

5.12

+0.0000

0.53

1.30

Dim
ensions in Inches

DIMENSIONS

1.375 - 0.0005

4.41

0.3125

11.97

1.51

FP

3.00

2.87

3.58

ZB

2.28

6.78

3.34

2.36

1.18

0.87

SK 92772

4.72

8.66

8.46
C (BR)

SK 92772AX

AB (BR)

AB
0.20

3.58 3.58

11.85
0.20

ZB

4.41

FP

2.87

2.47
3.74

2.36

1.18

6.89

0.87

2.44

2.28

7.90

4.41

0.53
5.51

4.72
8.46

8.66

SK 92772AX

2.36

2.36

0.3750

7.56
2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

1.30

5.12

11.97

0.87

1.67

+0.0010

1.50 -0.0000

Motor Dimensions
Standard efficiency

63S/L

71S/L

4.51

4.86

Energy efficiency
AB

80S/L

90S/L

100L

80LH

90SH/LH

100LH

5.59

5.79

6.65

112M
7.05

132S
112MH

132SH

7.05

8.03

AB (BR)

4.84

5.24

5.59

5.79

6.77

7.17

N/A

7.91

19.95

20.80

21.67

23.76

24.98

26.04

27.04

29.70

C (BR)

22.15

23.09

24.19

26.71

28.58

29.74

N/A

33.91

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.65

102

G1142 Subject to Change Without Notice

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92772 + NEMA
SK 92772
C1

0.20

2.47
2.44

7.90
+0.0000

1.375 - 0.0005

2.36

1.18

SK 92772AX

Dim

8.46

C1
11.85
4.41

GA1
BB1

UY1

5.51

AK1

BD1

2.87

2.47
2.44

AJ1

BF1

3.74

2.36

1.18

6.89

0.87

0.53

2.28

7.90

4.41
1.30

5.12

11.97

Y1

0.87

4.72
8.46

8.66

SK 92772AX

2.36

2.36

0.3750

2.17

7.56

1.67

+0.0010

1.50 -0.0000

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

16.65

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

16.65

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

20.48

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

20.48

7.25

1.38

250TC

7.25

8.500

0.23

9.17

0.59

1.625

1.80

0.375

21.37

7.86

1.65

www.nord.com

G1142 Subject to Change Without Notice

103

ALTERNATE SHAFTS SEE PAGES 112 - 116

0.20

CC

U1

3.58 3.58

ZB

DIMENSIONS

4.72

8.66

0.20

AJ1

BF1

3.34

ensions in Inches

3.33

5.12

0.3125

11.97
4.41

0.53
6.89

UY1

-11

1.51

4.02

BB1
Y1

16

GA1

0.87

x2

AK1

BD1

16

2
5

0.87

5
1

5.51

CC

4.41

3.00

1.30

ZB

2.87

3.58

11.85

U1

6.78

2.28

6.78

SK 92772 + Motor
AB (BR)
C (BR)

AB
8.47

C
16

x2

4.35

1.51
2.87

7.087

0.16
0.63

ZB

-11

9.84 (250)

12.09
4.53

16

2
5
8

+0.0000

5
1

11.79

1.375 - 0.0005

5.47 3.00

0.3125

3.58

FP

SK 92772VF

3.00

8.66

0.53

8.46

Dim

0.20

3.58

AB (BR)

C (BR)

AB

5.47

11.79

2.87

7.087

4.53

0.16

0.53

8.46

0.63
8.66

SK 92772AF

SK 92772AFS
9.37

2.36

2.36

2.17

0.3750

7.56
2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

9.84 (250)

12.09

ZB

4.35

1.69

FP

ensions in Inches

DIMENSIONS

SK 92772AF

1.67

1.63

+0.0010
1.50 -0.0000

1.73

+0.0009
1.50 -0.0000

+0.0000

1.50 -0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

80S/L

90S/L

100L

AB

4.51

4.86

80LH

90SH/LH

100LH

112MH

132SH

5.59

5.79

6.65

7.05

7.05

AB (BR)

4.84

8.03

5.24

5.59

5.79

6.77

7.17

N/A

7.91

C
C (BR)

19.89

20.74

21.61

23.70

24.92

25.98

26.98

29.64

22.09

23.03

24.13

26.65

28.52

29.69

N/A

33.85

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.65

Energy efficiency

104

112M

G1142 Subject to Change Without Notice

132S

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92772 + NEMA
SK 92772VF
C1
8.47

GA1

x2

BB1
Y1
AK1

1.51

AJ1

BF1

ensions in Inches

SK 92772AF

C1
11.79

GA1

4.35

BB1

UY1

AK1

BD1

2.87

7.087

4.53

9.84 (250)

12.09

Y1

1.69

AJ1

BF1

0.16

0.53

8.46

0.63

ALTERNATE SHAFTS SEE PAGES 112 - 116

5.47

CC

U1

3.58

ZB

8.66

SK 92772AF

SK 92772AFS
9.37

2.36

2.36

2.17

0.3750

2.17

7.56

1.67

1.63

+0.0010
1.50 -0.0000

1.73

+0.0009
1.50 -0.0000

+0.0000

1.50 -0.0006

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

16.59

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

16.59

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

20.42

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

20.42

7.25

1.38

250TC

7.25

8.500

0.23

9.17

0.59

1.625

1.80

0.375

21.31

7.86

1.65

www.nord.com

DIMENSIONS

0.53

8.46

Dim

3.00

8.66

0.20

UY1
U1

4.35
16

-11

0.16
0.63

CC

BD1

7.087

4.53

9.84 (250)

12.09

2
5

ZB

2.87

16

+0.0000

5
1

1.375 - 0.0005

5.47 3.00

0.3125

3.58

11.79

G1142 Subject to Change Without Notice

105

SK 92772 + Motor
SK 92772VZ

AB (BR)

C (BR)

AB

6.78

6.78

3.00

16

2
5
8

11.79
16

x2

ZB

4.35

-11

0.20
3.43

FP

2.87
+0.0000

1.375 - 0.0005

0.3125

6.30

4.53

4.331

12.09

1.51

0.16

8.66

M8x0.51
5.12

0.315x0.47

Dim
ensions in Inches

DIMENSIONS

SK 92772AZ

AB (BR)

C (BR)

AB

8.66

11.79

ZB

0.20

0.16

3.43 3.43

FP

2.87

6.30

4.53
0.20

M8x0.51

0.16

5.12

SK 92772AZ

0.315x0.47

SK 92772AZS
9.37

2.36

2.36

2.17

0.3750

7.56
2.17

ALTERNATE SHAFTS SEE PAGES 112 - 116

4.331

12.09

4.35

1.67

1.63

+0.0010
1.50 -0.0000

1.73
+0.0009

1.50 -0.0000

+0.0000

1.50 -0.0006

Motor Dimensions
Standard efficiency

63S/L

71S/L

80S/L

90S/L

100L

AB

4.51

4.86

80LH

90SH/LH

100LH

112MH

132SH

5.59

5.79

6.65

7.05

7.05

AB (BR)

4.84

8.03

5.24

5.59

5.79

6.77

7.17

N/A

7.91

C
C (BR)

19.89

20.74

21.61

23.70

24.92

25.98

26.98

29.64

22.09

23.03

24.13

26.65

28.52

29.69

N/A

33.85

FP

5.09

5.72

6.43

7.19

7.90

8.87

8.87

10.45

ZB

0.51

0.51

0.51

1.06

1.06

1.38

1.38

1.65

Energy efficiency

106

112M

G1142 Subject to Change Without Notice

132S

For Other Connection


Possibilities please see

108 & 109

www.nord.com

SK 92772 + NEMA
SK 92772VZ

C1
11.79

GA1

4.35
16

x2

BB1

AK1

2.87

0.3125

1.375 -0.0005

0.20
0.16

M8x0.51
5.12

0.315x0.47

SK 92772AZ

Dim

ensions in Inches

8.66

AJ1

BF1

+0.0000

6.30

4.53

4.331

12.09

1.51

3.43

UY1

-11

C1
11.79

ZB

CC
GA1

4.35

BB1

UY1

BD1

AK1

2.87

BF1

0.20
0.16

6.30

4.53

4.331

12.09

Y1

U1

8.66

0.20
3.43 3.43

AJ1

M8x0.51

0.16

5.12

SK 92772AZ

0.315x0.47

SK 92772AZS
9.37

2.36

2.36

2.17

0.3750

2.17

7.56

1.67

1.63

+0.0010
1.50 -0.0000

1.73
+0.0009

1.50 -0.0000

+0.0000

1.50 -0.0006

NEMA Dimensions
Type

AJ1

AK1

BB1

BD1

BF1

U1

UY1

Y1

C1

CC

ZB

56C

5.88

4.500

0.20

6.61

0.43

0.625

0.71

0.188

16.59

4.29

0.51

140TC

5.88

4.500

0.20

6.61

0.43

0.875

0.96

0.188

16.59

4.29

0.51

180TC

7.25

8.500

0.23

9.17

0.59

1.125

1.24

0.250

20.42

7.25

1.38

210TC

7.25

8.500

0.23

9.17

0.59

1.375

1.52

0.312

20.42

7.25

1.38

250TC

7.25

8.500

0.23

9.17

0.59

1.625

1.80

0.375

21.31

7.86

1.65

www.nord.com

DIMENSIONS

G1142 Subject to Change Without Notice

107

ALTERNATE SHAFTS SEE PAGES 112 - 116

U1

5
16
1
2
5
8

3.00

Y1

6.78

CC

BD1

6.78

ZB

Solid Input Shaft


Type - W
SK 92072
CC
FV
FW
FZ
FU

TAP
Dim
ensions in Inches

DIMENSIONS

KEY

SK 92172 - SK 92772
CC
FV
FW
FZ
FU
TAP
KEY

Unit

CC

FW

FV

FU

SK 92072

3.89

0.16

1.13

0.500

SK 92172

3.89

0.16

1.13

0.500

SK 92372

4.33

0.16

1.57

0.625

SK 92672

4.33

0.16

1.57

0.750

SK 92772

4.84

0.12

1.97

0.875

108

FZ
+0.0000
- 0.0005
+0.0000
- 0.0005
+0.0000
- 0.0005
+0.0000
- 0.0005
+0.0000
- 0.0005

TAP

0.56

1/4-20

0.56

1/4-20

0.70

1/4-20

0.83

1/4-20

0.96

1/4-20

G1142 Subject to Change Without Notice

KEY
1/
8
1/
8

x 1/8
x 1/8
3/
3
16 x /16
3/
3
16 x /16
3/
3
16 x /16

Unit Dimensions
x 7/8
x 7/8
x 1 1/4
x 1 1/4
x 1 5/8

78
84
90
96
102

www.nord.com

IEC Inputs
SK 92072 - SK 92772

AJ1

CC
BF1

V1

DIMENSIONS

ensions in Inches

Dim

Y1

BD1

AK1

U1

UY1

ALTERNATE SHAFTS SEE PAGES 112 - 116

BB1

IEC Dimensions (mm)


Input
IEC 63

CC
85

AJ1
115

AK1
95

BB1
3.5

BD1
140

BF1
M8

U1
11

V1
23

UY1
12.8

Y1
4

IEC 71

85

130

110

4.0

160

M8

14

30

16.3

IEC 80

102.5

165

130

4.0

200

M10

19

40

21.8

IEC 90

102.5

165

130

4.0

200

M10

24

50

27.3

IEC 100

125.5

215

180

5.0

250

M12

28

60

31.3

IEC 112

125.5

215

180

5.0

250

M12

28

60

31.3

IEC 132

175

265

230

5.0

300

M12

38

80

41.3

10

IEC 160

300

250

6.0

350

M16

42

110

45.3

12

IEC 180
IEC 200

300
350

250
300

6.0
6.0

350
400

M16
M16

48
55

110
110

51.8
59.3

14
16

www.nord.com

G1142 Subject to Change Without Notice

109

B14 Flange Design


Option VZ
SK 92072 VZ
AJ
AK

Dim

BB

ensions in Inches

DIMENSIONS

V
N

BF

BD

SK 92172 VZ - SK 92772 VZ
AJ
AK
ALTERNATE SHAFTS SEE PAGES 112 - 116

BD

BF

!GENTITLE- MAX
!GENTITLE- RU

!GENTITLE- LL

!GENTITLE- INSERT

V
N

!GENTITLE- MAX
!GENTITLE- RU

!GENTITLE- LL

!GENTITLE- RU

!GENTITLE- MAX
!GENTITLE- RU
!GENTITLE- MAX
!GENTITLE- RU

!GENTITLE- MAX
!GENTITLE- RU

BB

Type

Mounting dimensions flange B14

Shaft dimensions

BD

AK

AJ

BB

BF(mm)

SK 92072

VZ

4.04

2.756

3.35

0.10

M8 x 13

1.57

1.69

SK 92172

VZ

4.72

3.150

3.94

0.12

M6 x 13

1.57

1.73

SK 92372

VZ

5.51

3.740

4.53

0.12

M8 x 13

1.97

2.20

SK 92672

VZ

5.51

3.740

4.53

0.12

M8 x 13

2.36

2.52

SK 92772

VZ

6.30

4.331

5.12

0.16

M8 x 13

2.76

2.95

110

G1142 Subject to Change Without Notice

www.nord.com

Output Shaft Protection


Covers - Option AZH
SK ... AZH
mHB

DIMENSIONS
ALTERNATE SHAFTS SEE PAGES 112 - 116

Dim

ensions in Inches

hHB

Type
hHB

mHB

SK 92072

AZH

1.34

3.41

SK 92172

AZH

1.46

3.90

SK 92372

AZH

1.65

4.61

SK 92672

AZH

SK 92772

AZH

1.65
1.73

4.72
5.16

www.nord.com

G1142 Subject to Change Without Notice

111

Solid Shaft
Dimensions
Solid Shaft Dimensions

V
M

KEY

FOOTED

KEY

VF

VZ

Dim
ensions in Inches

DIMENSIONS

UNIT
SK 92072
SK 92172
SK 92372
SK 92672
SK 92772

Diameter Tolerance

UY

KEY SIZE

KEY QTY

0.750
20mm
0.750
20mm

+0.0000 / -0.0005
+0.015 / +0.002mm
+0.0000 / -0.0005
+0.015 / +0.002mm

1.50
40mm
1.50
40mm

0.83
22.5mm
0.83
22.5mm

3/16 x 3/16 x 1-1/4


6 x 6 x 32mm
3/16 x 3/16 x 1
6 x 6 x 32mm

1
1
1
1

DRILL & TAP


M
1/4-20
M6
1/4-20
M6

1.000
25mm
1.250
30mm
1.375
35mm

+0.0000 / -0.0005
+0.015 / +0.002mm
+0.0000 / -0.0005
+0.015 / +0.002mm
+0.0000 / -0.0005
-0.018 / +0.002mm

2.13
50mm
2.75
60mm
3.00
70mm

1.11
28.0mm
1.36
33.0mm
1.51
38.0mm

1/4 x 1/4 x 1-5/8


8 x 7 x 40mm
1/4 x 1/4 x 2-1/4
8 x 7 x 50mm
5/16 x 5/16 x 2-1/2
10 x 8 x 56mm

1
1
1
1
1
1

3/8-16
M10
1/2-13
M10
5/8-11
M12

Dimensions are in inches unless otherwise noted.


Metric Keys are captured in keyways.
For shaft sizes not shown, consult NORD.

112

G1142 Subject to Change Without Notice

www.nord.com

Hollow Shaft
Dimensions
Hollow Shaft Dimensions
(AZ-AF)

ADH

UH

UH

LH

Dim

ensions in Inches

LH

TYPE

UH

DIAMETER TOLERANCE

ADH

LH

DH

UYH

KEY QTY

0.84
0.56
28.3mm

KEY SIZE
wxhxl
3/16 x 3/16 x 2
1/8 x 1/8 x 7/8
8 x7 x 25mm

SK 92072 AZ/AF

0.750*
0.500
25mm

+0.0010 / -0.0000
+0.0010 / -0.0000
+0.021 / -0.000mm

4.57
4.57
116mm

0.98
0.98
30mm

1.38
1.38
35mm

SK 92172 AZ/AF

1.000*
25mm

+0.0010 / -0.0000
+0.021 / -0.000mm

5.43
138mm

1.18
30mm

1.57
40mm

1.09
28.3mm

1/4 x 3/16 x 2
8 x7 x 32mm

2
2

SK 92372 AZ/AF

1.1875*
1.250
1.4375
30mm

+0.0010 / -0.0000
+0.0010 / -0.0000
+0.0010 / -0.0000
+0.021 / -0.000mm

6.46
6.46
6.46
164mm

1.97
1.97
1.97
50mm

1.97
1.97
1.97
50mm

1.30
1.37
1.61
33.3mm

1/4 x 1/4 x 2-1/4


1/4 x 1/4 x 2-1/4
3/8 x 3/8 x 2-1/2
8 x 7 x 60mm

2
2
2
2

SK 92672 AZ/AF

1.375*
1.4375
1.500
35mm

+0.0010 / -0.0000
+0.0010 / -0.0000
+0.0010 / -0.0000
+0.025 / -0.000mm

6.69
6.69
6.69
170mm

2.36
2.36
2.36
55mm

2.17
2.17
2.17
60mm

1.52
1.61
1.67
38.3mm

5/16 x 5/16 x 2-1/2


3/8 x 3/8 x 2-1/2
3/8 x 3/8 x 2-1/2
10 x 8 x 60mm

2
2
2
2

SK 92772 AZ/AF

1.500*
1.4375
40mm

+0.0010 / -0.0000
+0.0010 / -0.0000
+0.025 / -0.000mm

7.56
7.56
192mm

2.36
2.36
60mm

2.17
2.17
55mm

1.67
1.61
43.3mm

3/8 x 3/8 x 2-1/4


3/8 x 3/8 x 2-1/4
12 x 8 x 60mm

2
2
2

2
2
2

* standard size
Dimensions are in inches unless otherwise noted.
For shaft sizes not shown, consult NORD.

www.nord.com

G1142 Subject to Change Without Notice

DIMENSIONS

DH

KEY

113

ALTERNATE SHAFTS SEE PAGES 112 - 116

UYH

Hollow Shaft
Dimensions
Hollow Shaft Foot Mount Dimensions
(AX)
UYH

ADH

UH

UH

DH

KEY

LH

LH

Dim
ensions in Inches

DIMENSIONS

TYPE
SK 92072 AX

UH

DIAMETER
TOLERANCE

ADH

LH

DH

UYH

KEY SIZE
wxhxl

KEY QTY

0.750*

+0.0010 / -0.0000

4.57

0.98

1.38

0.84

3/16 x 3/16 x 2

0.500

+0.0010 / -0.0000

4.57

0.98

1.38

0.56

1/8 x 1/8 x 7/8

ALTERNATE SHAFTS SEE PAGES 112 - 116

25mm

+0.021 / -0.000mm

116mm

30mm

35mm

28.3mm

8 X 7 x 25mm

SK 92172 AX

0.750

+0.0010 / -0.0000

5.28

1.18

1.38

0.84

3/16 x 3/16 x 2

20mm

+0.021 / -0.000mm

134

40

35

22.8

6 x 6 x 50mm

SK 92372 AX

1.1875*

+0.0010 / -0.0000

6.46

1.97

1.97

1.30

1/4 x 1/4 x 2-1/4

1.250

+0.0010 / -0.0000

6.46

1.97

1.97

1.37

1/4 x 1/4 x 2-1/4

1.4375

+0.0010 / -0.0000

6.46

1.97

1.97

1.61

3/8 x 3/8 x 2-1/2

SK 92672 AX

SK 92772 AX

30mm

+0.021 / -0.000mm

164mm

50mm

50mm

33.3mm

8 x 7 x 60mm

1.375*

+0.0010 / -0.0000

6.69

2.36

2.17

1.52

5/16 x 5/16 x 2-1/2

1.4375

+0.0010 / -0.0000

6.69

2.36

2.17

1.61

3/8 x 3/8 x 2-1/2

1.500

+0.0010 / -0.0000

6.69

2.36

2.17

1.67

3/8 x 3/8 x 2-1/2

35mm

+0.025 / -0.000mm

170mm

60mm

55mm

38.3mm

10 x 8 x 60mm

1.500*

+0.0010 / -0.0000

7.56

2.36

2.17

1.67

3/8 x 3/8 x 2-1/4

1.4375

+0.0010 / -0.0000

7.56

2.36

2.17

1.61

3/8 x 3/8 x 2-1/4

40mm

+0.025 / -0.000mm

192mm

60mm

55mm

43.3mm

12 x 8 x 60mm

* standard size
Dimensions are in inches unless otherwise noted.
For shaft sizes not shown, consult NORD.

114

G1142 Subject to Change Without Notice

www.nord.com

Shrink Disc Shaft


Dimensions
Shrink Disc Shaft Dimensions
(AZSH)

Customer Shaft

DH

UH

UH

ADH

ensions in Inches

Dim

SK 92072 AZSH
SK 92172 AZSH
SK 92372 AZSH
SK 92672 AZSH
SK 92772 AZSH

HOLLOW SHAFT
UH
TOLERANCE
1.000
+0.0008 / -0.0000

ADH

LB

LH

DH

CUSTOMER SHAFT
U
TOLERANCE
1.000
+0.0000 / -0.0005

5.67

1.22

1.26

1.38

25mm

+0.021 / -0.000mm

144mm

31mm

32mm

35mm

25 mm

1.000

+0.0008 / -0.0000

6.69

1.22

1.38

1.57

1.000

+0.0000 / -0.0005

25mm

+0.021 / -0.000mm

170mm

31mm

35mm

40mm

25mm

+0.000 / -0.013mm

+0.000 / -0.013mm

1.1875

+0.0009 / -0.0000

7.87

1.24

1.42

1.97

1.1875

+0.0000 / -0.0006

30mm

+0.021 / -0.000mm

200mm

31.5mm

36mm

50mm

30 mm

+0.000 / -0.013mm

1.375

+0.0009 / -0.0000

8.27

1.63

1.57

2.17

1.375

+0.0000 / -0.0006

35mm

+0.025 / -0.000mm

210mm

41.5mm

40mm

55mm

35 mm

+0.000 / -0.016mm

1.500

+0.0009 / -0.0000

9.37

1.63

1.73

2.17

1.500

+0.0000 / -0.0006

40mm

+0.025 / -0.000mm

238mm

41.5mm

44mm

55mm

40 mm

+0.000 / -0.016mm

* Non-shrink disc side diameter larger for clearance.

www.nord.com

G1142 Subject to Change Without Notice

115

ALTERNATE SHAFTS SEE PAGES 112 - 116

Type

DIMENSIONS

LB

LH

Fixing
Element Kit

SCREW

a3

Dim

ensions in Inches

DIMENSIONS

UH

RETAINING
WASHER

a2

PLUG

Inch Shaft Hollow Bore (in)


UH
D
a
0.5000
0.984
0.595
0.7500
1.181
0.557
1.0000
1.496
0.767
1.1875
1.575
0.769
1.2500
1.575
0.769
1.3750
1.772
0.946
1.4375
1.772
0.946
1.5000
1.772
0.946

a2

0.110
0.118
0.150
0.150
0.150
0.197
0.197
0.197

Screw
10 - 32 x 5/8
1/4 - 20 x 3/4
3/8 - 16 x 3/4
7-16 - 14 x 2-1/16
7-16 - 14 x 2-1/16
5/8 - 11 x 1-1/2
5/8 - 11 x 1-1/2
5/8 - 11 x 1-1/2

a3
0.499
0.652
0.624
2.016
2.016
1.461
1.461
1.461

Screw

a3

1/4 - 20 x 1
3/8 - 16 x 1-1/4
5/8 - 11 x 2-1/4
5/8 - 11 x 2-1/4
5/8 - 11 x 2-1/4

Metric Hollow Bore (mm)


UH
D
a
a2
Screw
25
38
19
3.8
M10 x 45
30
40
19
3.8
M10 x 45
35
45
23.5
3.8
M12 x 55
40
55
24
8
M16 x 70
, , - Each fixing element kit may contain up to 3 different kinds of screws

116

LOCK
WASHER

G1142 Subject to Change Without Notice

0.902
1.124
2.211
2.211
2.211

a3

41.8
43.8
54
70

Screw

5/8 - 11 x 1
5/8 - 11 x 1
5/8 - 11 x 1

Screw
M10 x 30
M10 x 30
M12 x 35
M16 x 45

a3

0.961
0.961
0.961

a3
26.8
28.8
34
45

www.nord.com

Motors
Motors
Order Form
NEMA C-Face Motors
Engineering Information
Options
Environmental Options
AC Vector Drive Options
SK 300E Trio
AC Vector Drive
Additional Options
Ratings Tables
Dimensions
Connection Diagrams

DRIVESYSTEMS

www.nord.com
Nn
Fullload

In
Full-Load Current
230Va) 460Va)

[hp]

[kW]

[rpm]

[A]

[A]

63S/4

0.16

0.12

1700

0.88

0.44

63L/4

0.25

0.18

1680

1.12

0.56

71S/4

0.78

0.33

0.25

1710

1.56

71L/4

0.5

0.37

1720

1.90

80S/4

0.75

0.55

1710

2.70

1.35

80L/4

0.75

1650

3.66

1.83

90S/4

1.5

1.1

1660

4.84

2.42

90L/4

1.5

1660

6.34

3.17

2.2

1705

100L/4

9.0

4.50

3.7

1725

15.2

7.62

7.5

5.5

1735

19.8

9.9

132M/4

10

7.5

1735

25.8

12.9

160M/4

15

11

1770

38.4

19.2

G1142 - Subject to Change Without Notice

FV
FES

0.95

132S/4

100LA/4

FW

FU

Power
Pn

FS

Motor
Type

WE
CM

117

Motor
Order Form
Frame

Size

Poles

63
71
80
90
100
112
132

S
SH
M
MH
MX
L
LA
LH
LX

4
2
6
4-2
8-2
8-4
12-2
Other

Motor Options

Brake Size

Brake Options

SK
Electrical Motor Options
H - Energy Efcient Motor
TW - Thermostat
TF - Thermistor
SH - Space Heater (select voltage)

110 Volt
230 Volt 460 Volt
ISO H - Class H insulation
WU - High Resistance Rotor
4-2 - 2-Speed, 4/2 Pole, 1800/3600rpm
8-2 - 2-Speed, 8/2 Pole, 900/3600rpm
ECR - Single Phase Motor

BRE 5
BRE 10
BRE 20
BRE 40
BRE 60
BRE 100
BRE 150

Environmental Options

NSD+ - Nord Severe Duty Paint


NSDx3 - Nord Extreme Duty Paint
RD - Canopy Drip Cover
RDD - Double Fan Cover
KB - Condensation Drain Holes (plugged)
KBO - Condensation Drain Holes (open)
IP66 - IP66 Enclosure Protection
KKV - Terminal Box Sealed with Resin
AICM - Additional Insulation
EP - Epoxy Dipped Windings

MOTORS

Unpainted Aluminum Alloy

Stainless Steel Paint

NSD+ (gray)

NSD+W (white)

NSD-X3 (gray)

NSD-X3W (white)

Special _______

Rectier Selection
Rectier Wiring

Across the line (from motor terminal box)

Separate power source (frequency AC vector drive, soft starter)

AC Vector Drive Related Options


F - Blower Fan (200-575V 1 & 3 Phase)
FC - Blower Cooling Fan (115V, 1 Phase)
IG__ - Incremental Encoder
IG__P - Incremental Encoder with Plug
AG - Absolute Encoder
Additional Motor Options
OL - Totally Enclosed Non-Ventilated (TENV)
OL/H - (TENV) Without Fan Cover
WE - Second Shaft Extension (Fan Side)
HR - Hand Wheel
Z - High Inertia Cast Iron Fan
RLS - Motor Backstop (rotation viewing fan)

Clockwise
Counter-Clockwise
EKK - Small Terminal Box (not UL approved)
MS - Quick Power Plug Connector

Brake Supply Voltage

Braking Method

24 VDC

115 VAC

200 VAC

230 VAC

400 VAC

460 VAC

500 VAC

575 VAC

Other ____________

Method 10

Method 15

Method 20

Method 25

Method 30

Method 35

Method 40

Method 45

Method 50

Method 55

Hand Release Position


HL 2

HL 3

HL1

HL2

HL3

HL4

HL 1

Paint

HL - Hand Release Lever


FHL - Locking Hand Release Lever
HLH - Hand Release Lever with Hole
RG - Corrosion Protected Brake
SR - Dust and Corrosion Protected Brake
ADJ_____Nm - Adjust Brake Torque
BIP66 - IP66 Brake Enclosure
MIK - Micro-switch
BSH - Brake Heating/Bilar Coil
NRB1 - Quiet Brake Release
NRB2 - Quiet Brake Motor Operation
FBR - Brass Foil
DBR - Double Brake
G...P - High Performance Rectier
G...V - Sealed Rectier
IR - Current Sensing Relay

HL 4

Voltage & Frequency

Terminal Box Pos.

Integral to gearbox

NEMA C-Face

IEC B5 Mount

230/460V-60Hz

575V-60Hz

208V-60Hz

400V-50Hz

115/230V, 60Hz-1-ph.

Other

TB1

TB2

TB3

TB4

Conduit Entry Loc.

TB3

118

TB2

TB1

Mounting

CE I
CE II
CE III
CE IV

G1142 - Subject to Change Without Notice

II

IV

I*

TB4

Mtg. Pos. M1 Shown

III*

*Brakemotor

Mtg. Pos. M1 Shown

www.nord.com

General Options
Motor Options & Construction
NORD motors are stocked in one of two ways. The rst method is to stock a complete motor that is ready
to be assembled to a gear reducer or shipped as a stand alone motor. The second method, the motor is assembled from component parts. The Mod next to a motor option designates that the option can be added
to a complete motor by simple modication. The Build next to a motor option indicates that the motor will
need to be built from component parts in order to incorporate the motor option.
Motor Options
Description

AG
AICM
ECR

Mod

Build

Page

Absolute Encoder

135

Additional Insulation

129

Single Phase Motors, 60Hz

128

EKK

Small Terminal Box

EP

Epoxy Dipped Windings

Blower Cooling Fan

132

129
133

FC

Blower Cooling Fan

HR

Hand Wheel

130

IG...P

Incremental Encoder

134

ISO H

Class H Insulation

128

KB

Plugged Condensation Drain Holes

129

KBO

Open Condensation Drain Holes

129

133

KKV

Terminal Box Sealed with Resin

MS

Quick Power Plug Connector

132

OL

Totally Enclosed Non-Ventilated

130

OL/H

Totally Enclosed Non Ventilated without Fan Cover

129

130

RD

Canopy Drip Cover

129

RDD

Double Fan Cover

129

RLS

Motor Backstop

131

SH

Space Heater

128

TF

Thermistor

127

TW

Thermostat

127

WE

2nd Shaft Extension on Fan Side

130

WU

High Resistance Rotor

128

High Inertia Cast Iron Fan

131

IP66 Enclosure Protection

129

Paint Coatings

22

www.nord.com

G1142 - Subject to Change Without Notice

119

MOTORS

Abbreviation

Stocked NEMA
C-Face Motors
NEMA C-Face Motors

Stocked NEMA C-Face Motors

The National Electrical Manufacturers Association


(NEMA) provides standardization of electrical equipment, enabling customers to select from a range of
safe, effective and compatible products. A NEMA
C-face motor has a machined face with a pilot and
threaded holes for direct mounting onto a NORD reducer or other industrial equipment. NORD offers
NEMA C-face motors stocked as nished goods and
will also assemble NEMA C-face motors to your specications. For ratings, see page 140.

Stocked NEMA C-face motors are offered in standard


efciency, energy efcient and in a brakemotor design.
They are available in 230/460V-60Hz and 575V-60Hz
up to 10 hp. Part numbers for stocked NEMA C-face
motors are in the table below.

Motor Type

Assembled per Order NEMA C-Face Motors


NORD will assemble a NEMA C-face motor to your
specications based upon the available motor
options from this catalog.

Power

Part Number
230/460V-60Hz

Part Number
575V-60Hz

Weight
[lb]

1/6 hp
1/4 hp
1/3 hp
1/2 hp
3/4 hp
1 hp
1 hp
1.5 hp
2 hp
3 hp
5 hp
7.5 hp
10 hp
15 hp
20 hp
25hp
30hp

31110012
31610012
32110012
32610012
33110012
33610022
33610012
34110012
34610012
35110012
35610012
36410012
36710012
37310012
37510012
37610012
37810012

31110013
31610013
32110013
32610013
33110013
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a

7.9
9.3
11.9
13.9
17.6
19.8
19.8
26.5
30.9
39.7
46.3
97.0
121.3
160.9
178.6
276.3
307.2

1 hp
1 hp
1.5 hp
2 hp
3 hp
5 hp
7.5 hp
10 hp
15 hp
20 hp

33610094
33610092
34110092
34610092
35610092
36110082
36410092
36710092
37310092
37510092

33610095
33610093
34110093
34610093
35610093
36110083
36410093
36710093
37310093
37510093

19.8
19.8
26.5
30.9
39.7
83.6
97.0
121.3
160.9
198.4

1/6 hp
1/4 hp
1/3 hp
1/2 hp
3/4 hp
1 hp
1 hp
1.5 hp
2 hp
3 hp
5 hp
7.5 hp
10 hp
15 hp
20 hp

31110034
31610034
32110034
32610034
33110034
33610024
33610034
34110034
34610034
35110034
35610034
36410034
36710034
37310034
37510034

31110035
31610035
32110035
32610035
33110035
33610025
33610035
34110035
34610035
35110035
35610035
36410035
36710035
37310035
37510035

12.4
13.7
16.3
18.3
24.3
26.5
26.5
36.4
40.8
55.1
61.7
123.5
156.5
220.5
242.5

High Performance Motors


63S/4-56C
63L/4-56C
71S/4-56C
71L/4-56C
80S/4-56C
80L/4-56C
80L/4-143TC
90S/4-145TC
90L/4-145TC
100L/4-182TC
100LA/4-184TC
132S/4-213TC
132M/4-215TC
160M/4-254TC TW
160L/4-256TC TW
180MX/4-284TC TW
180LX/4-286TC TW

Energy Efcient Motors

MOTORS

80LH/4-56C
80LH/4-143TC
90SH/4-145TC
90LH/4-145TC
100LH/4-182TC
112MH/4-184TC
132SH/4-213TC
132MH/4-215TC
160MH/4-254TC TW
160LH/4-256TC TW

Brakemotors
63S/4-56C BRE5 HL
63L/4-56C BRE5 HL
71S/4-56C BRE5 HL
71L/4-56C BRE5 HL
80S/4-56C BRE10 HL
80L/4-56C BRE10 HL
80L/4-143TC BRE10 HL
90S/4-145TC BRE20 HL
90L/4-145TC BRE20 HL
100L/4-182TC BRE40 HL
100LA/4-184TC BRE40 HL
132S/4-213TC BRE60 HL
132M/4-215TC BRE100 HL
160M/4-254TC BRE 150 HL TW
160L/4-256TC BRE 250 HL TW
230/460V

motors have brake systems supplied with 230VAC to a GVE20L rectier that outputs 205VDC to the brake coil
575V motors have brake systems supplied with 575VAC to a GHE50L rectier that outputs 250VDC to the brake coil

120

G1142 - Subject to Change Without Notice

www.nord.com

Engineering Information
Standard Design & Construction
Standards

EPAct US Energy Efciency

All motors are in accordance with existing standards


and regulations:

The Energy Policy Act of 1992 (EPAct) covers


efciency levels of general purpose industrial electric
motors and became effective October 24, 1997. The
NEMA MG 1 - Motors and Generators:
basic goal of the law is to promote energy
Electrical performance
conservation. This law mandated energy efciency
Motors for operation on variable AC vector drive
requirements for many devices including some types
of industrial electric motors. The efciency levels are
UL 1004 Electric Motors
dened in NEMA MG-1 table 12-10. The regulations
CSA C22.2 No. 100-04 - Motors and Generators: to implement this law have been developed by the
Department of Energy (DOE).

Part 1
Part 5
Part 6
Part 8
Part 9
Part 11
Part 14

General rules
Types of enclosures
Types of cooling
Terminal lead designations and sense of rotation
Noise limits
Integrated thermal protection
Mechanical vibration

IEC 60038 Standard voltages


NORD motors carry the CE mark in accordance
with the Low Voltage Directive and, if installed
properly, the Electromagnetic Compatibility Directive (EMC). The CE mark is required for installation in European Union (EU) states.
Many NORD motors from frame size 63 to 315 are
an Underwriters Laboratories Recognized component per UL standard 1004.
Frames 63-132 File number E191510
Frames 160+ File number E227215

US

The Canadian Standards Association CUS mark


indicates that CSA has tested and approved NORD
motors according to both US and Canadian standards. It is equivalent to the Underwriters Laboratories RU recognition mark (UL standard 1004) and
the CSA mark according to CSA Standard C22.2
No. 100-04
Frames 63-132 File number LR112560
Frame 160+ File number LR13494
NORD Energy Efcient motors up to frame 160
have been evaluated by the United States Department of Energy and recieved a Certicate of
Compliance to certify the efciency ratings. The
certicate of compliance is CC 092B.
NORD energy efcient motors carry the CSA energy efciency verication mark. This mark ensures that CSA has veried that NORD motors are
designed and manufactured to meet energy efciency requirements number EEV112560.

www.nord.com

The law covers minimum efciency levels for general


purpose motors including:
Single-speed, polyphase NEMA T frame
(and IEC equivalents)
1 to 200 hp (0.75 to 150 kW)
1200, 1800 or 3600 rpm
NEMA design A and B
Continuous rated
Foot-mounted
230/460V-60Hz
The law excludes the following motor types from
minimum efciency levels:
Integral gearmotors
Brake motors
The NORD H line of energy efcient motors are
designed to meet the efciency levels dened by
EPAct. NORD offers these motors as an option in
combination with our high efciency gear units for
superior energy savings.
Efciency levels for enclosed 4-pole motors per
EPAct and NEMA MG 1 - in percent efciency [%]

Efciency for EPACT &


NEMA MG1 4-Pole Motors
hp

1.5

7.5

10

kW

0.75

1.1

1.5

2.2

3.7

5.5

7.5

Eff%

82.5

84.0

84.0

87.5

87.5

89.5

89.5

hp

15

20

25

30

40

50

60

kW

11

15

18.5

22

30

37

45

Eff%

91.0

91.0

92.4

92.4

93.0

93.0

93.6

hp

75

100

125

150

200

kW

55

75

90

110

150

Eff%

94.1

94.5

94.5

95.0

95.0

G1142 - Subject to Change Without Notice

121

MOTORS

Industrial Products
IEC 60034 parts 1, 5, 6, 8, 9, 11 and 14.

Engineering Information
Standard Design & Construction
Canadian Energy Efciency
The Energy Efciency Act and the Energy Efciency
Regulations establish minimum energy performance
levels for electric motors from 1 to 200 HP
(0.75 to 150 kW) for sale or lease in Canada.
The Energy Efciency Regulations were developed
by Natural Resources Canada (NRCan).
Certain National Electrical Manufacturers Association (NEMA) motors have been regulated since
Feb. 3,1995. Effective Nov. 27, 1997, the Energy
Efciency Regulations were amended to include
International Electrotechnical Commission (IEC) motors. This amendment also increased the minimum
energy performance levels that motors must meet.
For explosion-proof motors and motors contained
within an integral gear assembly, the effective date
of the Regulations is Nov. 27, 1999.
The regulations mandate that motors carry an energy efciency verication mark that is authorized by
Standards Council of Canada (SCC) accredited certication organization such as Canadian Standards
Association (CSA).

CEMEP Agreement
European Efciency Categories

MOTORS

CEMEP, the association of European Electric Motor


Manufacturers, has reached an agreement with the
European Commissions General Directorate for Energy that in the future all 2 and 4-pole low voltage
motors from 1 to 100kW will be categorized on the
basis of their efciency. The classication will be
displayed on the nameplate and in catalogs. The
following categories will be used: EFF1, EFF2 and
EFF3.

EFF1-indicates a high efciency factor.

EFF2-inicates an improved efciency


factor.

Indicates a standard efciency motors.

122

NORD supplies both motors of EFF1 and EFF2 categories


in its 4-pole motors. The category EFF2 motors are the
standard efciency motors and the EFF1 motors are
the H line of energy efcient motors.
In the future NORD will mark all of its 50-Hz motor
with the CEMEP efciency symbols.
kW

1.1

1.5

2.2

5.5

hp

1.5

5.4

7.5

EFF1
[%]

83.3

85.0

86.4

87.4

88.3

89.2

EFF2
[%]

76.2

78.5

81.0

82.6

84.2

85.7

EFF3
[%]

<76.2

<78.5

<81.0

<82.6

<84.2

<85.7

kW

7.5

11

15

18.5

22

30

hp

10

15

20

25

30

40

EFF1
[%]

90.1

91.0

91.8

92.2

92.6

93.2

EFF2
[%]

87.0

88.4

89.4

90.0

90.5

91.4

EFF3
[%]

<87.0

<88.4

<89.4

<90.0

<90.5

<91.4

kW

37

45

55

75

90

hp

50

60

75

100

120

EFF1
[%]

93.6

93.9

94.2

94.7

95.0

EFF2
[%]

92.0

92.5

93.0

93.6

93.9

EFF3
[%]

<92.0

<92.5

<93.0

<93.6

<93.9

Inverter/Vector Duty
NORD singlespeed motors are Inverter/Vector
Duty. The construction of the NORD motors insulating system takes into account the non-sinusoidal
wave forms produced by variable frequency drives.
NORD uses high grade insulating components and
extra rst turn protection as well as double coated
wire to ensure long service life when connected to
AC vector drives. NORD motors can produce full
torque at zero speed if properly sized, selected and
controlled.

G1142 - Subject to Change Without Notice

www.nord.com

Engineering Information
Standard Design & Construction
Voltage and Frequency

Tropical Protection (Anti-fungal)

NORD motors are available in a wide range of


voltages and frequencies for use in North America
and around the world. For a more detailed list of
choices see page 126.

As standard the NORD motor insulation system is


tropically protected. The insulating and construction
components are inorganic materials so they resist
fungal growth.

NORD motors designed for North American voltages


(208V, 230V, 460V and 575V) conform to the voltage
and frequency tolerances in NEMA MG-1. The voltage
tolerance is +/-10%, the frequency tolerance is +/- 5%
or a combined voltage and frequency tolerance of
+/-10%.

Insulation Class

Low Inertia

NORD motors are constructed with a thermal class F


insulating system. The motors are also designed for
a class B temperature rise (80C). The use of class F
insulation with a class B temperature rise provides
increased operating life. Motors constructed with
class H insulation are also available as an option.

The motor inertia in all NORD motors is extremely


low which allows for a much more dynamic motor
control capability. Low motor inertia is a signicant
advantage when using NORD motors with AC vector
drives or vector controllers. NORD motors can cycle
more frequently and require less mechanical energy
to start than standard NEMA frame motors. This
leaves more energy to start the load.

High Torque

Non-Sparking Fan
The standard NORD motor fan is a non-sparking design. The fan will also provide proper airow in either direction of rotation.

Terminal Block
Each NORD motor uses a terminal block, which
is a superior method of wire termination when
compared to pigtail leads. A terminal block ensures
long-term reliability of the power connections.

Insulation System
NORD motor insulation system is designed to provide
a superior degree of protection. NORD utilizes the
following insulation components:

Magnet wire double coated insulation


Varnish dip impregnation
Slot liners
Phase paper
Phase separators
Top sticks
Connecting wire sleeves

MOTORS

The NORD motors produce higher starting torque


than required by NEMA standards. This is achieved
through improved motor winding, rotor design and
construction.

Other motor manufacturers eliminate some of these


insulating components for cost reduction.

Inverter/Vector Duty Voltage Spikes


All NORD motors are constructed with an insulating
system designed to withstand the repeated voltage
spikes generated by modern AC vector drives.
The insulation system withstands the ratings in
conformance with NEMA MG 1-2006 Section 31.4.4.2
Voltage Spikes.
Vpeak = 3.1 Vrated with a Rise time 0.1s.

www.nord.com

G1142 - Subject to Change Without Notice

123

Engineering Information
Standard Design & Construction
Ambient Temperature

Duty Classes

NORD motors are designed to operate with a maximum ambient temperature of 40C (104F). If the
motors operating environment exceeds 40C, the
motors nominal power Pn either needs to be derated (see table below) or use upgraded insulation.

The following duty types are dened in IEC 60034-1.

Ambient temp [F]

113

122

131

140

Ambient temp [C]

45

50

55

60

0.96

0.92

0.87

0.82

De-rate factor

Duty Type
S1

Continuous operation at a constant load, the motor reaches thermal equilibrium

S2

Short-time operation at a constant load for a given time followed by a time of rest until the motor
is completely cooled down to ambient temperature.
Example: S2-10 minutes
Recommended values for determination: 10, 30 min.

S3

Intermittent operation sequential, identical run


and rest cycles with constant load. Temperature
equilibrium is never reached. Starting current has
little effect on temperature rise. The cyclic duration factor (cdf) indicates the portion of operation
time in relation to a complete duty cycle. The typical duty cycle time is 10 minutes, unless otherwise
specied.
Example: S3-40%
Recommended values for determination: 25, 40, 60%

S6

Continuous operation with intermittent load sequential, identical cycles of running with constant
load and running with no load. No rest periods.
Example: S6-40%
Recommended values for determination: 25, 40, 60%

Motor Rated Power = [Pn x De-rate factor]

Elevation
NORD motors are designed to operate at an elevation
of up to 3300 ft (1000 m) above sea level. At higher
elevations the air is thinner resulting in less cooling
capacity. If the motors nominal power Pn installation elevation exceeds 3300 ft (1000 m), the motor
either needs to be de-rated (see table below) or requires upgraded insulation.
Altitude [ft]

5000

6500

8200

10000 11500 13000

Altitude [m]

1500

2000

2500

3000

3500

4000

De-rate Factor

0.97

0.94

0.90

0.86

0.83

0.80

Motor Rated Power = [Pn x De-rate factor]

Service Factor
Motors rated 230/460V-60Hz and 332/575V-60Hz
have a service factor of 1.15. Almost all other
motors have a service factor of 1.1 or 1.0.

Explanation Excerpts

Power Increasing Factor for Short-term &


Intermittent Operation

MOTORS

Motor ratings in this catalog are based on continuous duty operation (S1). If a motor is designed for
S1 duty, but is to be operated for short-time or intermittent operation it can be subjected to higher
loads. The available motor power can be raised
above the motor rated power by the increasing
factor in the table below.
Duty Type

S2

S3

S6

Operating time

Cyclic duration factor (cdf)

Cyclic duration factor (cdf)

Increasing
factor
10 min

1.40

30 min

1.15

25%

1.33

40%

1.18

60%

1.08

25%

1.45

40%

1.35

60%

1.15

Motor Rated Power = [Pn x Increasing factor]

124

G1142 - Subject to Change Without Notice

www.nord.com

Engineering Information
Standard Design & Construction
Enclosure

Standard Construction

The NORD standard motors are provided with Totally


Enclosed Fan-Cooled (TEFC) with an IP55 enclosure
rating. Other enclosures are available, including
Totally Enclosed Non-Ventilated (TENV), Totally
Enclosed Blower-Cooled (TEBC), and IP66.

The motor integral cooling fan provides proper air


ow in either direction of rotation. The IEC cooling
classication is IC 411 according to IEC 60034-6.

1st digit
Foreign body protection

2nd digit
Water protection

No protection

Protected against solid


objects 50mm (2 in) in
diameter and larger

Protected against solid


objects 12 mm (1/2 in)
in diameter and larger

Protected against solid


objects 2.5 mm (0.1 in)
in diameter and larger

Protected against solid


objects 1 mm (0.04 in)
in diameter and larger

5
6

Protected against dust


Dust tight

Protected against
dripping water up to a
15 degree angle
Protection against
sprayed water
Protection against
splashed water
Protection against
water jets

Protection against high


pressure water jets

Protection against
intermittent
submersion in water

Protection against
continuous
submersion in water

-8

Protective Features
All NORD Motors and Speed Reducers are constructed
to provide a high degree of protection against wet
and severe environments. NORD Motors and Speed
Reducers are extremely well sealed against moisture
ingress and use corrosion and moisture resistant
components. NORD has recently made many
enhancements in the motor and gear units standard
construction to provide improved environmental
protection. Many of the standard protection features
of the NORD units are only available at an additional
cost from other motor and gear drive suppliers. NORD
designs all gearmotors, speed reducers and motors
for installation in harsh industrial, commercial and
municipal installation environments.

www.nord.com

Motors for Indoor Operation - Option Codes


Dry Conditions

Wet or Humid
Conditions

Ambient Temperature Fluctuation

KB, SH

Paint

NSD+

RD

RDD

RG

Protected against
dripping water

-7

No Protection

Vertical
Motor
Mount
Brakemotor

Motors for Outdoor Operation - Option Codes


Sheltered from
the Elements

Exposed to
the Elements

Ambient Temperature Fluctuation

KB, SH

KB, SH, KKV

Paint

NSD+

NSDx3

Vertical
Motor
Mount

RD

RDD

Brakemotor

RG

RG

Option Code Key


KB

Condensation Drain Holes - Plugged

SH

Page 129

Space Heater

Page 128

KKV

Terminal Box Sealed with Resin

Page 129

NSD+

Nord Severe Duty Paint

Page 22

NSDx3

Nord Severe Extreme Duty X3 Paint

Page 22

Canopy Drip Cover

Page 129

Double Fan Cover

Page 129

Corrosion Protected Brake

Page 163

RD
RDD
RG

G1142 - Subject to Change Without Notice

125

MOTORS

IP Enclosures per IEC 60034-5 - Simplied

Shaft lip seals on both ends of the motor shafts


Stator to endbell connections sealed to exclude moisture
Double coated magnetic wire insulation
Inverter/vector duty insulation system conforms to
NEMA MG1-1998, section 31.4.4.2 voltage spikes
Moisture resistant varnish dipped windings
improved varnish materials
Inorganic insulating components for tropical protection
Moisture resistant motor windings
Conduit box sealed with gaskets
Corrosion resistant alloy materials
Threaded cable entry holes

General Options
Voltage and Frequency

Poles / speeds

NORD motors are available in a number of voltages


and frequencies. The standard voltages are commonly
available. Optional voltages can be provided, but may
include an increase in price and additional lead time.
It also may be possible to provide motors with special
voltages and frequency operation points.

NORD offers a variety of single speed and two speed


motors in addition to the standard 4 pole motor.
NORD single speed motors are inverter/vector duty
rated, however, it is not recommended to run a
NORD two speed motor with an AC vector drive.
Number Synchronous
of Poles Speed at 60Hz

Standard Voltages
Single speed motors

Two speed motors

230/460V-60Hz (up to 30 hp)

460V-60Hz

460V-60Hz (40 hp and larger)

230V-60Hz

575V-60Hz

575V-60Hz

400V-50Hz

400V-50Hz

Optional Voltages
Single speed motors

Two speed motors

208V-60Hz
(up to 10 hp, not available in energy
efficient design)
380V-50Hz
415V-50Hz
380V-60Hz
Other voltages & frequencies available upon request

Synchronous
Speed at 50Hz

Notes:

1800 rpm

1500 rpm

3600 rpm

3000 rpm

1200 rpm

1000 rpm

Single Speed Motors


4

Two Speed Motors


4-2

1800/3600 rpm

1500/3000 rpm

Single winding

8-2

900/3600 rpm

750/3000 rpm

Two winding

8-4

900/1800 rpm

750/1500 rpm

Single winding

Other speeds available upon request.


Other voltages &
frequencies available
upon request

US Canadian Standard (CUS)


CUS motor construction defines that NORD motors
are constructed in accordance to UL 1004 (electric
motors) and CSA C22.2 No. 100-04 (motors and generators) guidelines. This option is standard for 208,
230, 460, and 575 Volt operation at 60 Hz.

MOTORS

Motors nameplated with the CUS option will be


marked
and
indicating that the Underwriters
Laboratories and CSA have tested and approved
NORD motors according to both US and Canadian
standards.

126

G1142 - Subject to Change Without Notice

www.nord.com

General Options
Motor Protection
Selecting the appropriate motor protective system
is a key factor in reliable motor operation. There
are two common classes of motor protection;
current based and motor temperature based.
Electrical installation codes require at least two
types of protection in the motors circuit, both of
which are normally current based. First is shortcircuit protection normally accomplished by fuses
or circuit breakers. Second is motor overload

Over current up to 200%


High inertia starting
Frequent motor starts
Stalling
Single phasing
Supply voltage deviations
Supply frequency deviations
Inadequate motor cooling
Bearing Damage

Thermostat (TW)

Fuses

Motor
Overloads

TW Ratings
NC (Normally Closed)

auto resetting

Voltage

6 to 500VAC

Current

1.6 A

Resistance

less than 50 m

Build

Three positive temperature coefcient (PTC) thermistors are connected in series in the motor windings,
one per motor phase. Thermistors require an external
tripping device. Upon reaching the limit temperature,
the thermistors change their resistance suddenly. In
connection with a tripping device, this property is
employed to monitor the motor temperature. The relay
built into the tripping device has a make-and-breakcontact, which is used in the control wiring. NORD
does not provide the external tripping device with
the TF thermistor option. You must request a thermistor tripping device separately. Many AC vecotor
drives and PLCs include a built in PTC thermistor
evaluation input.

www.nord.com

Bi-metallic Switch
(TW)

Build

Three bimetallic switches are connected in series in


the motor windings, one per motor phase. Upon
reaching the limit temperature, this device automatically opens circuits. The installer is responsible to wire the thermostat into the motor control
circuit. After the temperature has fallen below
the trip limit, the thermostat switch re-sets automatically. The auto resetting property must be
considered when designing the safety aspects of the
control scheme.

Thermistor (TF)

PTC Thermistor
(TF)

MOTORS

= Good protection
= Limited protection
= No protection

protection this is normally a device called a motor


overload or a heater. Current based protection
is effective in some conditions. NORD can provide
two different types of motor temperature based
protection, a PTC thermistor (TF) or a bi-metallic
thermostat (TW). Temperature based protection is
more effective motor protection in many situations,
see the table below.

TF Ratings
Transition Temperature

150 C +/- 5C

Resistance < Transition

20 ... 500 .

Resistance > Transition

> 4k .

Reed Voltage

< 7,5 V

Rated Current

< 1 mA

Motor Ambient Temp.

G1142 - Subject to Change Without Notice

40C

127

General Options
Space Heater (SH)

Build

Motors subjected to extreme temperature uctuations or severe climatic conditions can be damaged
by the formation of condensation. NORD can provide
motor anti-condensation space heaters inside the
motor to heat up the windings when the motor is
not operating. This will prevent moisture from condensing inside the motor. The space heaters must
not be switched on while the motor is running.

Space Heater Voltage Must be specied

High Resistance Rotor (WU)

Build

Using Silumin rotor material, NORD offers a high resistance rotor to soften the motors operation and
allow higher overload torques.

Single Phase Motors, 60Hz (ECR)

Build

The ECR series of single phase motors is intended


for demanding operation at 60Hz with a supply
voltage of 115V or 230V. The permissible voltage
range is 115/230V +/- 10%. The ECR motors have a
1.15 service factor and are available from 0.16 - 2
hp.

Voltages available
115V 50/60Hz
230V 50/60Hz
460V 50/60Hz
other voltages available on request

Class H Insulation (ISO H)

Build

NORD motors can be manufactured with class H insulation system. Standard NORD motors include
double coated magnetic wire windings. When these
windings are paired with a class H insulation it
provides extra temperature capacity for the motor
and will lengthen the motors life. Class H insulation
rated motors are also an advantage in some severe
applications:

MOTORS

Increased ambient temperature installations above


40C (104F)
Increased elevation installations above 3300 ft
(1000 m)
Applications with a high number of starts per hour.
Meets class H insulation motor specications
Lower operating frequency when used with
AC vector drive systems
For additional information on insulation class see
page 123.

128

G1142 - Subject to Change Without Notice

www.nord.com

Environmental
Options
Mod

NORDs standard paint coating is a two component,


aliphatic polyurethane nish contaning 316 stainless steel material. This gray stainless steel paint
has excellent appearance and outstanding physical
properties. It is suitable for both indoor and outdoor applications. For more information and an
explanation of all of our paint options please see
page 22.

NORD motors can be equipped with condensation


drain holes. These drain holes are placed in the
motor endbells at the lowest possible point. The
drain holes are closed at the factory with plastic snap
in plugs. They allow for condensation accumulation in the motor to drain after the closing plugs are
removed.
The motor drain holes can be provided by NORD
either open (KBO) or sealed with a closing plug (KB).

IMPORTANT NOTE
The motor must be installed in the mounting orientation specied on the nameplate or the drain
holes will not function properly and may result
with the motor lling with water.
Build

KB drain holes are plugged for shipment. In order for


the holes to effectively drain moisture, the plugs must
be removed before using the motor.

Condensation Drain Holes,


Open (KBO)

Build

KBO drain holes are shipped open (not plugged).

IP66 Enclosure Protection

Mod

Terminal boxes can be sealed with a exible, electrically safe resin to ensure that contaminants, water, and
moisture cannot pass through the terminal box into
the stator body. This option is helpful in extremely
dusty, wet and humid environments. Another environment where this option is helpful is in installations
that have frequent large temperature swings where
condensation may form.

Additional Insulation (AICM)

Condensation Drain Holes

Condensation Drain Holes,


Plugged (KB)

Terminal Box Sealed with Resin (KKV)

Build

NORD can provide additional insulation inside the


motor to provide additional electrical protection in
extremely wet or corrosive environments. An electrically safe insulating material is coated internally in
the stator windings and on the rotor body

Epoxy Dipped Windings (EP)

Build

In extremely wet environments, the motor windings


are dipped in epoxy for improved moisture protection.
The motor can also be treated with the standard NORD
Severe Duty + (NSD+) package for an even higher
degree of protection.

Canopy Drip Cover (RD)

Mod

For wet or dirty installations where the


fan end of the motor is mounted up, thus
allowing water or debris to fall into the
motors fan guard, NORD offers a canopy
drip cover to block this falling water or
debris.

Double Fan Cover (RDD)

Mod

For wet or dirty installations where the


fan end of the motor is mounted up, the
NORD Double Fan Cover provides protection against falling or wind blown water,
snow, dirt or debris from entering the back
of the motor.

Mod

NORD motors can be provided with an IP66 enclosure


protection. IP66 protection is suitable for wet, highpressure wash down and extremely dusty environments, and includes all requirements included in IP65
enclosure protection.
IP

1st digit
Foreign body protection

IP

2nd digit
Water protection

Dust tight

Protection against high


pressure water jets

www.nord.com

G1142 - Subject to Change Without Notice

129

MOTORS

Paint Coatings

Additional
Options
Totally Enclosed Non-Ventilated (OL)

Mod

NORD can provide totally enclosed non-ventilated


(TENV) motor enclosure. TENV motors provide benets in certain operating environments; such as extremely dusty or dirty applications, where cooling fans
may have material accumulation, which can be detrimental to the motor and the application. The OL series
of motors are the standard fan cooled motor construction including the fan cover, but provided without the
fan. TENV motors can also be used to reduce cooling
fan noise on a standard motor.

2nd Shaft Extension on Fan Side (WE)

Build

NORD can provide a second shaft extension on the


fan side of the motor that protrudes through the
fan cover. This extension can be used as a power
take-off or to mount customer supplied devices
such as encoders and tachometers.
The shaft extension can be provided on both motors with and without brakes. The shaft extension can not be used on motors with blower fans
(F) or (FC). For dimensions see pages 148 - 151.

A TENV motors frame size is larger then a totally enclosed fan cooled (TEFC) motor. For intermittent operation, a TENV motor can be operated at a 50% duty
cycle at full rated power.

Hand Wheel (HR)

Totally Enclosed Non-Ventilated,


without Fan Cover (OL/H)

Build

Build

Motors can be supplied with a hand wheel provided on the second shaft extension. The hand
wheel can be used for manual operation during
power outages, or for machine positioning setup.
For dimensions see pages 148 - 151.

MOTORS

The OL/H series of TENV motors are more compact in


space than the OL series. They do not include the rotor
shaft extension through the back bearing end bell or
the fan cover.

WARNING
The customer is required to provide appropriate
safety guarding of the rotating hand wheel.

130

G1142 - Subject to Change Without Notice

www.nord.com

Additional
Options
High Inertia Cast Iron Fan (Z)

Build

An optional cast iron motor cooling fan is available.


This fan is used as a mechanical soft start and/or soft
stop. This fan adds inertia to the motor. The high inertia fan can also be used for a ywheel effect to store
mechanical energy. This can be helpful in smoothing
rapid load changes. The cast iron fan replaces the standard plastic motor fan. The motor length is the same
as a brakemotor.
Motor Frame

Fan Inertia Jz[lb-ft2]

71

0.0475

80

0.1140

90

0.2375

100

0.2684

112

0.5653

132

0.9500

Motor Backstop (RLS)

Build

NORD can provide backstops on many motor frames.


A backstop will prevent the motor from rotating in
one direction. A common use is to prevent a motor
from allowing a load to move backwards when power
is removed. A motor brake can also be used for this
same purpose. A backstop adds length to the motor.
For the motor length extension, see the table below.

CW

The allowable direction of rotation


must be specied in the order.

CCW

Motor Size
80S/L
90S/L
100L
112M
132S/M
160M/L
180MX/LX
200L
225S/M
250M
280S/M

www.nord.com

Backstop Torque
[lb-in]
1150
1150
1150
3270
3270
7880
7880
9120
9120
22130
51330

MOTORS

Allowable Shaft Rotation


Clockwise - Back of Motor
Counter Clockwise - Back of Motor
Minimum Speed
[rpm]
860
860
860
750
750
670
670
630
630
400
320

G1142 - Subject to Change Without Notice

Motor Extension
[in]
2.52
2.95
3.58
3.66
4.21
6.57
6.73
6.57
6.57
9.84
11.02

131

Additional
Options
Quick Power Plug Connector (MS)

Mod

The quick power plug connector (MS) is a simple and


fast way to connect and disconnect a motor or brake
motor. The MS connector is available on NORD
three-phase motors from frame size 63 to 132. The
motor connections are made by a modular power
plug manfacturer by Harting. After the rst installation, the motor can be quickly changed by simply
plugging and unplugging the electrical connections.
This will ensure the new motor is properly wired.
This is a signicant advantage to equipment builders
who fabricate machinery on site and then ship to
another location. The motor with the MS connector
can simply be plugged in during nal installation.
NORD supplies the male connector half mounted on
the motor conduit box. The customer must supply
the female connector half mounted on the power
wiring. NORD supplies a protective plastic cover on
the motor male connector half to protect from dirt
and damage prior to installation.

Motor Power Plug Kits:


Includes conduit box, mounting hardware & Male
Harting Motor Plug
P/N
11035350
13035350
16035350
16335350

Motor size
63 + 71
80 + 90 + 100
112
132

Power Plug Positions

Power plug position must be specied

Power Plug Position


I

II

III

Small Terminal Box (EKK)

Mod

The motor terminal box can be provided as a smaller,


one-piece terminal design. This option is valid for
standard motors 0.16 - 10 hp and is not available for
Brakemotors.
MOTORS

Advantages:

Simple motor wiring


Accurate wiring of motor at nal job site
Fast motor replacement
Accurate wiring of replacement motor
Ideal for portable equipment
Reduces the required personnel for
motor replacement
Faster motor changes reduce down time

Plug ratings:
Manufacturer
Connector
Number of Pins
Voltage
Current

132

Harting
HAN 10 ES/HAN 10ESS
Cage Clamp Connectors
10-Male
600VAC per UL/CSA
16A - Continuous

EKK Dimensions
Motor Frame
63
71
80
90
100
112
132

G1142 - Subject to Change Without Notice

g1
3.94
4.29
4.88
5.08
5.51
5.91
6.85

n
2.95
2.95
3.62
3.62
3.62
3.62
4.13

p
2.95
2.95
3.62
3.62
3.62
3.62
4.13

S3
2x M16 x 1.5
2x M16 x 1.5
2x M20 x 1.5
2x M20 x 1.5
2x M20 x 1.5
2x M20 x 1.5
2x M25 x 1.5

www.nord.com

AC Vector Drive
Related Options
Blower Cooling Fan (F & FC)

Mod

NORD offers continuous running motor mounted


cooling fans that provide motor cooling at low
motor speeds. When a motor is operated on an AC
vector drive at low frequency, standard rotor fans do
not provide adequate airow for cooling. NORDs
separate powered motor cooling fans provide that
necessary airow. These separately powered fans
replace the standard motor fan cover and fan.
Blower
Cooling
Fan

Option F 3ph & 1ph 220-575V 50/60Hz


Voltage
[V]

63
71
80
90
100
112
132
160 - 225

230 277
230 277
230 277
230 277
230 277
230 277
230 277
230 277

63
71
80
90
100
112
132
160 - 225

220 332
220 332
220 332
220 332
220 332
220 332
220 332
220 322

63
71
80
90
100
112
132
160 - 225

380 575
380 575
380 575
380 575
380 575
380 575
380 575
380 575

Current
[A]

50Hz Ratings
Power
[W]

Voltage
[V]

Single phase connection - (Delta)


0.11
38
230 277
0.12
41
230 277
0.13
44
230 277
0.25
88
230 277
0.28
88
230 277
0.31
107
230 277
0.27
89
230 277
0.41
140
230 277
Three phase low-voltage connection - (Delta)
0.08
23
220 290
0.08
24
220 290
0.08
25
220 290
0.21
64
220 290
0.21
66
220 290
0.23
70
220 290
0.25
74
220 290
0.49
165
220 290
Three phase high-voltage connection - (Y)
0.04
23
380 500
0.04
25
380 500
0.04
26
380 500
0.12
62
380 500
0.12
66
380 500
0.13
70
380 500
0.14
75
380 500
0.28
165
380 500

Current
[A]

Power
[W]

0.10
0.10
0.11
0.26
0.26
0.26
0.29
0.45

27
28
29
72
70
73
82
128

0.10
0.10
0.01
0.28
0.27
0.27
0.32
0.52

27
30
29
86
86
85
96
155

0.05
0.05
0.05
0.16
0.16
0.16
0.18
0.29

29
30
29
82
83
82
96
155

MOTORS

60Hz Ratings
Motor Frame

Option FC 115V 50/60Hz 1ph


60Hz Ratings
Motor Frame

Voltage
[V]

63
71
80
90
100
112

100 135
100 135
100 135
100 135
100 135
100 135

www.nord.com

Current
[A]

50Hz Ratings
Power
[W]

Voltage
[V]

Single Phase Connection - (Delta)


0.23
42
100 135
0.23
47
100 135
0.27
57
100 135
0.46
102
100 135
0.53
105
100 135
0.60
115
100 135

G1142 - Subject to Change Without Notice

Current
[A]

Power
[W]

0.30
0.30
0.30
0.57
0.54
0.55

42
44
43
78
78
80

133

AC Vector Drive
Related Options
Incremental Encoder (IG..P)

Build

NORD can provide an incremental encoder mounted on


the back of a motor or brake motor. Commonly encoders
are used as speed or position feedback devices for use with
AC drives, motion controllers or PLCs. Below are standard
encoders; however, others can be supplied on request.

Encoder nomenclature must be specied.

Standard Motor
with Encoder

Encoder with
Brake Option

Encoder with
F Type Blower Fan

Brake Option, Blower Fan


with Encoder

Encoder nomenclature
Wiring Diagram

M12 Connector
Interface

4
5

Encoder Type: Quadrature


Differential Marker pulse

Pin

Conn

Cord

0V

WH

+V

BN

GN

A\

YE

GY

B\

PK

BU

Z\

RD

Nut

Gnd

Open

MOTORS

IG1 P
IG4 P
IG11 P
IG41 P
IG12 P
IG42 P
IG13 P
IG43 P
Interface
TTL/RS422 (26C31)
TTL/RS422 (26C31)
HTL/Push-pull (IC-WE)
Line Driver (7272)
Logic [VDC]
5
5
10-30
5-30
Pulse Count [PPR]
1024
4096
1024
4096
1024
4096
1024
4096
Power Supply [VDC]
4-6
4-6
10-30
10-30
10-30
10-30
5-30
5-30
Part Number
19551500 19551520 19551502 19551522 19551501 19551521 19551503 19551523
Max Current Draw [mA]
100
150
Max Frequency [kHz]
300
Ambient Temperature [F]
-4 to185
Enclosure
IP66
Cable
M12 8-pin male plug

Pre-fabricated Encoder Cables


NORD can provide Turck pre-fabricated encoder molded cordsets (M12, 8-pin, shielded, twisted pair)
Length
2m
5m
10m
15m
Field Wireable
Custom

134

In-line
NORD P/N
19551580
19551581
19551582
19551583
19551588
order from Turck

Turck P/N
E-RKC 8T-264-2
E-RKC 8T-264-5
E-RKC 8T-264-10
E-RKC 8T-264-15
CMB 8181-0
E-RKC 8T-264

Right-angle
NORD P/N
Turck P/N
19551584
E-WKC 8T-264-2
19551585
E-WKC 8T-264-5
19551586
E-WKC 8T-264-10
19551587
E-WKC 8T-264-15
order from Turck
E-WKC 8T-264

G1142 - Subject to Change Without Notice

www.nord.com

AC Vector Drive
Related Options
Encoders for NORD AC Drives

Absolute Encoder (AG)

NORD AC vector drives with encoder inputs are designed to use TTL/RS422 encoders. There are also advantages in using an encoder with the 10-30VDC power supply system. The NORD AC vector drives can use
a wide range of pulse counts, however the 1024PPR
version provides good performance with minimal interference issues. A 4096 PPR encoder can also be
used and will provide increased precision in some application but has some increased concerns with noise
interference.

Absolute encoders offer a unique value (voltage, binary count, etc.) for each mechanical position. When
an absolute encoder is powered up, the position of the
encoder is known. Absolute encoders are available in
single or multi-turn versions. The encoder is attached
under the fan cover with eld bus connection outside
the fan cover.

Recommended encoder: IG11P 1024PPR/TTL/10-30VDC


Alternate encoder: IG41P 4096PPR/TTL/10-30VDC

Resolution: up to 17 bits of resolution per turn


(131,072 steps) with 4096 turns (12 bits of turns)

Build

Absolute encoders can be provided to meet a variety


of specications:

MOTORS

Interfaces: Synchronous serial interface (SSI), SSI with


incremental track, ProBus, DeviceNet, CANopen,
CANlift, and other interfaces

www.nord.com

G1142 - Subject to Change Without Notice

135

AC Vector Drive
SK 300E Trio
NORDAC SK 300E
Motor Mounted Frequency AC Vector Drive
For select HP ratings, NORD can provide a fully programmable,
high performance AC vector drive mounted on the
motor. This motor mounted AC vector drives:

Eliminates the need to separately mount & wire the AC drive


Insures AC vector drive/motor compatibility
Has an IP 55 washdown duty enclosure
Provides Electronic Motor Overload protection
Insures smooth constant torque operation down
to 2 Hz (check motor thermal limitations)
Features a unique plug-in construction where the
program stays with the motor, minimizing return to
service time in the event of AC vector drive replacement

SK 300E AC Vector Drive Ratings

200-240 VAC 3 phase 50/60 Hz input, through 3 HP


380-480 VAC 3 phase 50/60 Hz input, 3/4 through 5 HP
Full range of built-in pre-engineered options available
For dimensions see page 152

Selection Steps
1) Choose the SK300E-trio AC vector drive based on motor ratings and input line voltage
2) Select the required Trio Interface (TI)
3) Select the braking resistor if required
4) Select additional customer based I/O if required (SK CU2-STD)
5) Select cover mounted technology unit if required
6) If remote wall mounting is required
7) Select any needed programming tools

Step 1: AC vector drive Selection


MOTORS

Basic NORD
Motor
Description
63 S/4
63 L/4
71 S/4
71/L/4
80 S/4
80 L/4
90 S/4
90 L/4
100 L/4
100 L/40

Power
Rating
HP/kW
0.16 / 0.12
0.25 / 0.18
0.33 / 0.25
0.50 / 0.37
0.75 / 0.55
1.00/ 0.75
1.50/ 1.1
2.00/ 1.5
3.00/ 2.2
5.00/ 3.7

240 VAC Input Inverter


Type
SK 300E
-370-323-B
-370-323-B
-370-323-B
-370-323-B
-550-323-B
-750-323-B
-111-323-B
-151-323-B
-221-323-B
Not Available

P
[in]
5.12
5.12
5.71
5.71
6.5
6.5
7.2
7.2
7.91
7.91

480 VAC Input Inverter


Type
SK 300E
-550-340-B
-550-340-B
-550-340-B
-550-340-B
-550-340-B
-750-340-B
-111-340-B
-151-340-B
-221-340-B
-401-340-B

AC Vector Drive Ratings


Type designation SK 300E

-370-323-B -550-323-B -750-323-B -111-323B -151-323-B -221-323-B -550-340-B -750-340-B -111-340-B -151-340-B -221-340-B -301-340-B -401-340-B

Supply Voltage
Motor Rating

3 Phase 200-240 VAC +/- 10%, 47-63 Hz

3 Phase 380-480 VAC, -20%/+10%, 47-63 Hz

1/2 HP

3/4

1 HP

1 1/2 HP

2 HP

3 HP

3/4 HP

1 HP

1 1/2 HP

2 HP

3 HP

4 HP

Rated Output Current Amps [RMS]

2.2

5.5

9.5

1.6

2.2

3.7

5.5

9.2

Typical Output Current Amps [RMS]

3.1

4.2

5.6

7.7

9.8

13.3

2.5

3.1

4.2

5.2

7.7

9.8

12.9

136

G1142 - Subject to Change Without Notice

5 HP

www.nord.com

AC Vector Drive
SK 300E Trio
Step 2: Selection of Trio Interface (TI)

SK 300E Options & Related Information

Following selection of the appropriate SK 300E AC


vector drive rating from the preceding chart, an appropriate Trio Interface (TI) must be specied. The
Trio Interface (TI) is an adapter that replaces the motor conduit box and contains a circuit board that the
SK 300E plugs into.

Step 3: Braking Resistors


Braking Resistor Options for SK 300E for mounting on
Trio Interface

A typical TI is shown below

SK TI 0/1

For standard 380-480 VAC units

SK TI 0/1 - 230

For standard 200-240 VAC units

SK TI 0/2

For 380-480 VAC units using Harting connectors

SK TI 0/2 230

200-240 VAC units using Harting connectors

Harding H10E series connector options for side


1(CE1) of SK TI 0/2 (and -230) Interfaces
LE H10E

Socket for AC supply input

MA H10E

Plug for motor output

Conduit plate options for side 3(CE3) of SK TI 0/2


(and -230) Interfaces
SK DA4

Plate with 4 x M16

SK DA2

Plate with 2 x M20 and 1 x M16


(Provided as standard with SK TI 0/2)

SK DA1

Plate with 1 x M25 and 2 x M16

SK DA0

Plate with no entries

For use with SK TI 0/1 adapters


SK BR3-120/100-TI 0/1

120 ohm/100 W for all ratings


except 5 HP

SK BR3-82/200-TI 0/1

82 ohm/200 W for 5 HP only

For use with SK TI 0/2 adapters


SK BR3-120/100-TI 0/2

120 ohm/100 W for all ratings


except 5 HP

SK BR3-82/200-TI 0/2

82 ohm/200 W for 5 HP only


MOTORS

SK 300E Trio Interface (TI) Types

During dynamic braking, energy is delivered from the


load through the motor (acting as a generator) to the
AC vector drive. The AC vector drive dissipates this
energy as heat via the integral brake chopper to the
optional external braking resistors.

Added related components for Trio Interfaces


P/N 018524200

M20 x adapter
(Qty 2 provided as standard on assembled trios)

P/N 011015410

Adapter to mount Trio Interface on


63 & 71 frame motors

P/N 013097000

Gasket to mount Trio Interface on


63 & 71 frame motors

www.nord.com

G1142 - Subject to Change Without Notice

137

AC Vector Drive
SK 300E Trio
Step 4: Customer I/O Based
Control Interface Option - SK CU2-STD
The standard I/O based control available via the Trio
Interface can be expanded via selection of an optional
Customer Unit, SK CU2-STD, that plugs into the Trio
Interface. Interface I/O points are listed on the following
chart:

Technology Unit (TU) Name Description


SK TU2-POT
SK TU2-CTR
SK TU2-PBR
SK TU2-PBR-24V

SK TU2-AS1

Probus eld bus interface powered


by customer 24 VDC supply
Probus eld bus interface with
clamp on connectors
AS (Actuator/Sensor) Interface

SK TU2-CAO

CANopen eld bus interface

SK TU2-DEV

DeviceNet eld bus interface

SK TU2-IBS

InterBus eld bus interface

SK TU2-DECKEL

Original blank cover for TU slot


(in case TU option is removed)

SK TU2-PBR-KL

I/O on standard Trio Interface Additional I/O on


SK CU2-STD Option
1 X programmable digital input 4 X programmable digital input
5 VDC and 15 VDC
2 X single-ended analog inpower supplies
puts
RS 485 interface via M-12
+10 VDC reference supply
connector and terminals
1 X programmable relay out- 1 X selectable/programmable
put
analog/digital output
PID control access

Step 5: Cover Mounted


Technology Unit (TU) Options

Analog reference potentiometer


box with L/Off/R control switch
Digital control/programmer with
4 digit, 7 segment LED display
Probus eld bus interface

Step 6: Wall Mounting Option Kit,


SK WMK-DA1
The wall mounting kit enables placing the SK 300E
AC vector drive on a nearby wall or the machine
instead of directly on the NORD motor or gearmotor.
The Trio Interface (TI) is still required and all other
options can be used.

MOTORS

A variety of pre-engineered plug in Technology Unit


(TU) options can be ordered to replace the standard
blank cover of the SK 300E AC vector drive. Only a
single TU can be installed on the AC vector drive at a
given time. Available units include operator and eld
bus interfaces:

138

G1142 - Subject to Change Without Notice

www.nord.com

AC Vector Drive
SK 300E Trio
Step 7 : Additional Tools &
Related Interface Options
In addition to the cover mounted SK TU2-CTR option,
there are several additional options that enable simple programming and control of the SK 300E:
Handheld Parameter Box (P-Box) with 10 foot cable, SK
PAR-2H
Detachable external add-on unit that can be used
to program and display parameters and control
the operation of the connected SK 300E. Features multi-line plain text display selectable in
six languages. Manages and stores up to ve
unique AC vector drive programs. Cable plugs into
M-12 connector in side of Trio Interface.
Panel Mount Parameter Box (P-Box), SK PAR-2E
Panel Mount version of Parameter Box with same
functionality as SK PAR-2H. Installs in cut-out in front
of customer supplied operator panel. Interface connection is performed by customer with their shielded
cable via terminals on SK PAR-2E and SK 300E.

Optional accessories required to interface user PC to


SK 300E via NORD CON are:
SK IC1 RS 485 to RS 232 interface converter
Enables communication between RS 232 port on computer and RS 485 port on SK 300E
Cable SK 300E
10 foot cable that connects between the 9-Pin D shell
connector on the SK IC1 and the M-12 connector on
the side of the SK 300E Trio Interface.

Electromechanical Brake Interface


& Coil Voltage Selection
As standard, the SK 300E provides a dedicated high
voltage DC power supply and coordination software
to directly control an Electromechanical Brake. This is
equivalent to using a half wave rectier, so the brake
coil voltage must be specied per the following chart:

NORD CON Software


Available free at NORD Website
NORD CON Software is a Windows-based PC program
that enables the control and programming of NORDAC AC vector drives. It provides for accessing up
to 31 AC vector drives simultaneously via the RS485
interface. It features both off-line and on-line programming and data management modes.
NORD CON allows user to:
Program AC vector drives and upload/download
parameter les
Control connected AC vector drives for
test/troubleshooting
Monitor connected AC vector drives and examine up
to four variables versus time with built-in oscilloscope
feature
Display parameter information in six languages

www.nord.com

440 480 VAC

205 VDC

200 240 VAC

105 VDC

380 415 VAC

180 VDC

MOTORS

Nominal Inverter AC Input Voltage Brake Coil Voltage

The brake gets connected to terminals +Br and Br on


the Trio Interface

Motor overload protection


Electronic motor overload protection is provided as
standard on the SK 300E AC vector drive. If required,
more precise protection can be achieved via the use
of motor thermostats (TW) or thermistor sensors (TF).
These devices can be interfaced to the SK 300E via the
programmable digital input to indicate a motor over
temperature error.

G1142 - Subject to Change Without Notice

139

Performance Data

230/460V 60Hz

Standard Efciency
Inverter duty TEFC
Synchronous speed 1800rpm @ 60Hz 4-pole Three-phase
Voltages: 230/460V 60Hz 1.15 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
Fullload

In
Full-Load Current
230V
460V

Ia/In

Code
Letter

Torque
Tn

Ta/Tn

Tk/Tn

pf

Jm
Inertia

[%]

[lb-ft2

[hp]

[kW]

[rpm]

[A]

[A]

[%]

63S/4

0.16

0.12

1700

0.88

0.44

245

5.92

2.1

2.2

0.66

52

0.005

63L/4

0.25

0.18

1680

1.12

0.56

275

8.99

2.1

2.2

0.71

57

0.0067

71S/4

0.33

0.25

1710

1.56

0.78

310

12.3

2.5

2.4

0.64

63

0.017

71L/4

0.5

0.37

1720

1.90

0.95

355

18.0

2.45

2.6

0.69

71

0.0204

80S/4

0.75

0.55

1710

2.70

1.35

355

27.0

2.2

2.2

0.71

72

0.0259

80L/4

0.75

1650

3.66

1.83

390

38.1

2.2

2.3

0.74

70

0.0345

90S/4

1.5

1.1

1660

4.84

2.42

445

55.6

2.7

2.6

0.78

73

0.055

90L/4

1.5

1660

6.34

3.17

465

75.8

2.55

2.5

0.80

74

0.074

100L/4

2.2

1705

9.0

4.50

490

108

2.3

2.6

0.81

82

0.107

100LA/4

3.7

1725

15.2

7.62

510

180

2.7

3.1

0.75

81

0.141

132S/4

7.5

5.5

1735

19.8

9.9

545

267

2.45

2.75

0.82

86

0.55

132M/4

10

7.5

1735

25.8

12.9

645

363

2.9

3.2

0.84

87

0.752

Pn
Nn
In
Ia
Ia/In
Tn
Ta

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

[lb-in]

Eff.

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

140

G1142 - Subject to Change Without Notice

www.nord.com

Performance Data

230/460V 60Hz / EE

Energy Efcient (EPAct)


Inverter duty TEFC
Synchronous speed 1800rpm @ 60Hz 4-pole Three-phase
Voltages: 230/460V 60Hz 1.15 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
Fullload

In
Full-Load Current
230V
460V

Ia/In

Code
Letter

Torque
Tn

Ta/Tn

Tk/Tn

pf

Jm
Inertia

[%]

[lb-ft2]

82.5

0.051

[hp]

[kW]

[rpm]

[A]

[A]

[%]

80LH/4

0.75

1750

3.88

1.94

600

90SH/4

1.5

1.1

1740

4.3

2.15

630

53.1

3.5

3.8

0.76

84.0

0.085

90LH/4

1.5

1745

6.3

3.15

670

72.1

4.3

4.5

0.71

84.0

0.092

100LH/4

2.2

1765

8.6

4.3

790

105

3.6

4.7

0.73

87.5

0.178

112MH/4

3.7

1770

14.4

7.2

810

176

4.0

4.8

0.76

87.5

0.304

132SH/4

7.5

5.5

1780

20.9

10.5

820

259

4.3

4.6

0.74

89.5

0.75

132MH/4

10

7.5

1770

27.0

13.5

735

356

3.2

4.0

0.78

89.5

0.84

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

36.0

4.6

4.3

0.59

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

Pn
Nn
In
Ia
Ia/In
Tn
Ta

[lb-in]

Eff.

www.nord.com

G1142 - Subject to Change Without Notice

141

Performance Data

575V 60Hz

Standard Efciency
Inverter duty TEFC
Synchronous speed 1800rpm @ 60Hz 4-pole Three-phase
Voltages: 332/575V 60Hz 1.15 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
In
Full-load Full-Load
Current
575V

Ia/In

Code
Letter

Torque
Tn

Ta/Tn

Tk/Tn

pf

Jm
Inertia

[%]

[lb-ft2

[hp]

[kW]

[rpm]

[A]

[%]

63S/4

0.16

0.12

1700

0.37

245

5.92

2.1

2.2

0.66

52

0.005

63L/4

0.25

0.18

1680

0.46

275

8.99

2.1

2.2

0.71

57

0.0067

71S/4

0.33

0.25

1710

0.66

310

12.3

2.5

2.4

0.64

63

0.017

71L/4

0.5

0.37

1720

0.8

355

18.0

2.45

2.6

0.69

71

0.0204

80S/4

0.75

0.55

1710

1.12

355

27.0

2.2

2.2

0.71

72

0.0259

80L/4

0.75

1650

1.46

390

38.1

2.2

2.3

0.74

70

0.0345

90S/4

1.5

1.1

1660

1.94

445

55.6

2.7

2.6

0.78

73

0.055

90L/4

1.5

1660

2.54

465

75.8

2.55

2.5

0.80

74

0.074

100L/4

2.2

1705

3.6

490

108

2.3

2.6

0.81

82

0.107

100LA/4

3.7

1725

6.1

510

180

2.7

3.1

0.75

81

0.141

132S/4

7.5

5.5

1735

7.92

545

267

2.45

2.75

0.82

86

0.55

132M/4

10

7.5

1735

10.3

645

363

2.9

3.2

0.84

87

0.752

Pn
Nn
In
Ia
Ia/In
Tn
Ta

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

[lb-in]

Eff.

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

142

G1142 - Subject to Change Without Notice

www.nord.com

Performance Data

575V 60Hz / EE

Energy Efcient (EPAct)


Inverter duty TEFC
Synchronous speed 1800rpm @ 60Hz 4-pole Three-phase
Voltages: 332/575V 60Hz 1.15 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
In
Full-load Full-Load
Current
575V

Ia/In

Code
Letter

Torque
Tn

Ta/Tn

Tk/Tn

pf

Jm
Inertia

[%]

[lb-ft2]

82.5

0.051

[hp]

[kW]

[rpm]

[A]

[%]

80LH/4

0.75

1750

1.5

600

90SH/4

1.5

1.1

1740

1.75

630

53.1

3.5

3.8

0.76

84.0

0.085

90LH/4

1.5

1745

2.45

670

72.1

4.3

4.5

0.71

84.0

0.092

100LH/4

2.2

1765

3.4

790

105

3.6

4.7

0.73

87.5

0.178

112MH/4

3.7

1770

5.6

810

176

4.0

4.8

0.76

87.5

0.304

132SH/4

7.5

5.5

1780

8.3

820

259

4.3

4.6

0.74

89.5

0.75

132MH/4

10

7.5

1770

10.8

735

356

3.2

4.0

0.78

89.5

0.84

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

36.0

4.6

4.3

0.59

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

Pn
Nn
In
Ia
Ia/In
Tn
Ta

[lb-in]

Eff.

www.nord.com

G1142 - Subject to Change Without Notice

143

Performance Data

200-208V 60Hz

Standard Efciency
Inverter duty Induction motor TEFC
Synchronous speed 1800rpm @ 60Hz 4-pole Three-phase
Voltages: 208V 60Hz 1.15 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
Full-load

In
208V

Ia/In

Code
Letter

Torque
Tn

Ta/Tn

Tk/Tn

pf

Jm
Inertia

[%]

[lb-ft2

[hp]

[kW]

[rpm]

[A]

[%]

63S/4

0.16

0.12

1700

0.97

245

5.93

2.1

2.2

0.66

52

0.005

63L/4

0.25

0.18

1680

1.24

275

9.38

2.1

2.2

0.71

57

0.0067

71S/4

0.33

0.25

1710

1.73

310

12.2

2.5

2.4

0.64

63

0.015

71L/4

0.5

0.37

1720

2.10

355

18.3

2.45

2.6

0.69

71

0.0181

80S/4

0.75

0.55

1710

2.99

355

27.6

2.2

2.2

0.71

72

0.0304

80L/4

0.75

1650

4.05

390

38.2

2.2

2.3

0.74

70

0.0392

90S/4

1.5

1.1

1660

5.35

445

57.0

2.7

2.6

0.78

73

0.0670

90L/4

1.5

1660

7.01

465

75.9

2.55

2.5

0.80

74

0.0855

100L/4

2.2

1705

9.95

490

111

2.3

2.6

0.81

82

0.107

100LA/4

3.7

1725

16.8

510

183

2.7

3.1

0.75

81

0.162

132S/4

7.5

5.5

1735

21.9

545

272

2.45

2.75

0.82

86

0.553

132M/4

10

7.5

1735

28.5

645

363

2.9

3.2

0.84

87

0.753

Pn
Nn
In
Ia
Ia/In
Tn
Ta

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

[lb-in]

Eff.

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

144

G1142 - Subject to Change Without Notice

www.nord.com

Performance Data

400V 50Hz

Standard Efciency (EFF2)


Inverter duty TEFC
Synchronous speed 1500rpm @ 50Hz 4-pole Three-phase
Voltages: 400V (380-420) 50Hz 1.0 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
Full-load

In
Full-Load
Current
a)
380-420V

Ia/In

Code Torque Ta/Tn


Letter
Tn

Tk/Tn

pf

Eff
Full
load

Eff
75%
load

[lb-in]

Eff
Class

Jm
Inertia

[hp]

[kW]

[rpm]

[A]

[%]

[%]

[%]

63S/4

0.16

0.12

1335

0.46

245

7.55

1.8

1.9

0.76

50.0

b)

b)

[lb-ft2]
0.005

63L/4

0.25

0.18

1325

0.62

260

11.4

1.8

1.9

0.80

56.5

b)

b)

0.0066

71S/4

0.33

0.25

1380

0.76

330

15.2

2.2

2.1

0.77

61.3

b)

b)

0.015

71L/4

0.5

0.37

1360

1.1

320

22.8

2.1

2.3

0.75

62.7

b)

b)

0.018

80S/4

0.75

0.55

1375

1.52

330

33.6

1.9

2.0

0.73

71.5

b)

b)

0.03

80L/4

0.75

1375

2.1

350

45.8

2.0

2.1

0.74

69.7

b)

b)

0.039

90S/4

1.5

1.1

1445

2.98

500

63.9

3.2

3.4

0.69

77.4

79.0

EFF2

0.067

90L/4

1.5

1440

3.73

540

87.5

3.1

3.6

0.73

79.3

80.0

EFF2

0.085

100L/4

2.2

1440

5.22

510

128

2.3

3.0

0.74

81.1

81.1

EFF2

0.107

100LA/4

1460

7.2

540

172

2.7

3.3

0.73

82.7

83.4

EFF2

0.16

112M/4

5.4

1445

8.3

530

232

2.3

2.8

0.80

86.0

84.0

EFF2

0.28

132S/4

7.5

5.5

1445

11.4

540

319

2.1

2.7

0.81

85.8

89.0

EFF2

0.55

132M/4

10

7.5

1445

14.8

550

436

2.5

2.8

0.84

87.0

86.0

EFF2

0.75

a) Motors 3 hp(2.2 kW) and below are rated 230 /400Y volts, motors above 3 hp (2.2 kW) are rated 400 /690Y-volts
b) EFF classes levels not applicable motor outside the power range covered by the aggreement
-

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

www.nord.com

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

G1142 - Subject to Change Without Notice

MOTORS

Pn
Nn
In
Ia
Ia/In
Tn
Ta

145

Performance Data

400V 50Hz / EE

Energy Efcient (EFF1)


Inverter duty TEFC
Synchronous speed 1500rpm @ 50Hz 4-pole Three-phase
Voltages: 400V (380-420) 50Hz 1.0 Service Factor
Continuous Duty 40C Ambient up to 3300ft Elevation
Class B temperature rise Class F insulation
Motor
Type

Power
Pn

Nn
In
Full-load Full-Load
Current
400V * a)
(380-420V)

Ia/In

Code Torque Ta/Tn


Letter
Tn

[lb-in]

Tk/Tn

pf

Eff
Full
load

Eff
75%
load

[%]

[%]

Eff
Class

Jm
Inertia

[hp]

[kW]

[rpm]

[A]

[%]

[lb-ft2]

90SH/4

1.5

1.1

1430

2.51

520

64.6

2.8

3.1

0.75

84.0

85.1

EFF1

0.082

90LH/4

1.5

1435

3.59

560

87.7

3.6

3.7

0.71

85.0

85.3

EFF1

0.093

100LH/4

2.2

1465

4.88

685

126

3.3

4.0

0.74

87.5

87.9

EFF1

0.17

112SH/4

1460

6.7

715

172

3.25

4.2

0.72

87.4

90.0

EFF1

0.28

112MH/4

5.4

1455

8.9

685

224

3.4

4.1

0.74

88.3

90.2

EFF1

0.30

132SH/4

7.5

5.5

1470

12

750

314

3.8

4.15

0.73

90.1

90.5

EFF1

0.75

132MH/4

10

7.5

1470

15.5

665

428

2.9

3.5

0.77

90.8

91.0

EFF1

0.84

a) Motors 3 hp(2.2 kW) and below are rated 230 /400Y volts, motors above 3 hp (2.2 kW) are rated 400 /690Y-volts
Pn
Nn
In
Ia
Ia/In
Tn
Ta

Full load power


Full load speed
Full load current
Locked-rotor current
Locked-rotor current ratio (%)
Full-load torque
Locked-rotor torque

Ta/Tn
Tk
Tk/Tn
pf
Eff
Jm

Locked-rotor torque ratio


Break-down torque
Break-down torque ratio
Power factor
Normal efciency
Motor inertia

MOTORS

146

G1142 - Subject to Change Without Notice

www.nord.com

Connection Diagrams
Frames 63-132
230 / 460V, 60Hz, 3 200 / 400V, 50Hz, 3
190 / 380V, 60Hz, 3

Frames 160 +
230 / 460V, 60Hz, 3 200 / 400V, 50Hz, 3
190 / 380V, 60Hz, 3

Frames 160 +
230 / 460V, 60Hz, 3 200 / 400V, 50Hz, 3
190 / 380V, 60Hz, 3

460 / 800V, 60Hz, 3 230 / 400V, 50Hz, 3


208 / 360V, 60Hz, 3 400 / 690V, 50Hz, 3
332 / 575V, 60Hz, 3

120094410

T7
T1

T8
T2

T9
T3

T6

L2
V1 T2

U1 T1

T5

L2

L3

L2

L1

L3

T2 (V1)

W1 T3

L3

L1

L1

high voltage

T1 (U1)

T3 (W1)

V2 T5

V5 T8

U2 T4

U5 T7

T7 (U3)

T4 (U2)

W2 T6

W5 T9

T9 (W3)

T6 (W2)

T8 (V3)

L2
V1 T2

U1 T1
T8

T1
L1

T2
L2

T3

W1 T3

L3

L1

low voltage

T1 (U1)

L2

T8 (V3)

T2
V1
L2

T3
W1
L3

T6

T4

T5

W2

U2

V2

T5 (V2)

V2 T5

V5 T8

U2 T4

U5 T7

T7 (U3)

T4 (U2)

W2 T6

W5 T9

T9 (W3)

T6 (W2)

*JUMPER WIRES NEEDED

Low Voltage

T5
V2

L3

T2 (V1) T3 (W1)

L3

L1

T9

YY

T7

YY

T6

T1
U1
high voltage L1

T1
U1

YY

low voltage

T5

T4
U2

T6
W2

T5 (V2)

High Voltage

T4

WIRING DIAGRAM
3 PHASE MOTOR

high voltage

T4

WIRING DIAGRAM
3 PHASE MOTOR

WIRING DIAGRAM
3 PHASE MOTOR

WIRING DIAGRAM
3 PHASE MOTOR

low voltage

T2
V1

L1

T3
W1
L3

L2

2 - SPEED MOTORS
SINGLE WINDING (4-2 & 8-4 POLE)
Normal Brake Reaction Time

120094440

Rapid Brake Reaction Time


(DC - Switching)
Rectifier
1

DC
VB
Brake
V - Brake Voltage
B
Terminals 1 & 2
- AC brake power input
Terminals 3 & 4
- DC switching, fast react
Terminals 5 & 6
- Brake coil, DC voltage out
* Customer supplied contact

STANDARD
BRAKE RECTIFIER

VB
DC
Brake

VB

V - Brake Voltage (AC)


B
Terminals 1 & 2 - AC Brake Power Input
Terminals 3 & 4 - DC Switching, Fast React Terminals
Terminals 5 & 6 -DC Voltage Output to Brake.

D
C
C
O
I
L

Rapid Brake Reaction Time


(DC Switching - Internal)

GPU
Rectifier
2 3 4

VB
V - Brake Voltage (AC)
B
Terminals 1 & 2 - AC Brake Power Input
Terminals 3 & 4 - No Jumper Connected
Terminals 5 & 6 - DC Voltage Output to Brake.

D
C
C
O
I
L

T4
2U

L2

L3

T5
2V

T6
2W

HIGH SPEED
GPE
Rectifier
1

D
C
C
O
I
L

VB

V - Brake Voltage (AC)


B
Terminals 1 & 2 - AC Brake Power Input
Terminals 3 & 4 - DC Switching, Contactor - IEC AC3
Terminals 5 & 6 -DC Voltage Output to Brake.

Use with P/Ns 19140230 & 19140240

(DC Switching - External)

GPE BRAKE
RECTIFIER

1
2

L1

Rapid Brake Reaction Time

GPU BRAKE
RECTIFIER

GPU
Rectifier
2 3 4

Rectifier
1

120094460

120094450

(AC Switching)

T1 1U T2 1V T3 1W

T4
2U

T5
2V

T6
2W

LOW SPEED
T1 1U T2 1V T3 1W

2 - SPEED MOTORS
SINGLE WINDING

Normal Brake Reaction Time


(AC - Switching)

L1 L2 L3
Customer Supplied
Starter Contacts
2 - SPEED MOTORS
DUAL WINDING (8-2 POLE)

TO
CONTROL
DEVICE

* MAX. OPERATING
VOLTAGE 2.5V.
* SWITCH TEMP.
155C
* RESPONSE TIME
< 5 SECONDS

TERMINAL
BLOCK

TO
CONTROL
DEVICE

L1

* NC (NORMALLY CLOSED)
* CONTACTS RATED 1.6A
AT 2.50 VAC
* 6-500 VAC
WORKING RANGE
* AUTOMATIC RESET AT
30 15C TEMP. DROP

THERMISTATS
TW OPTION

T4
2U

L3

T5
2V

T6
2W

T1
1U

T2
1V

T3
1W

T4
2U

T5
2V

T6
2W

LOW SPEED
T1
1U

L1

OPTION F 1 PH

L2

HIGH SPEED

120095230

120095240

THERMISTOR
TF OPTION

FROM MOTOR

T2
1V

L2

T3
1W

L3

OPTION F 3 PH
FROM MOTOR

230V
50 / 60 Hz
220-332V
50 / 60 Hz

* CAPACITOR IS SUPPLIED

TO
CONTROL
DEVICE

* CAPACITOR IS SUPPLIED

G1142 - Subject to Change Without Notice

SPACE HEATER
SH OPTION

120095220

BLOWER COOLING FAN


F OPTION

120095250

120095450

www.nord.com

TERMINAL
BLOCK

380-575V
50 / 60 Hz

1 PHASE
115V*
50/60 Hz

BLOWER COOLING FAN


FC OPTION

MOTORS

TERMINAL
BLOCK

2 - SPEED MOTORS
DUAL WINDING

FROM MOTOR

147

Dimensions
Motor Options

CRD

FV

CRDD

CHR

PRD

FS

WE

RD

RDD

DHR

FR
FU

FES

PRDD

FW

Standard
Motor

HR

CM

Option IG

CM

CRD

PRD

Option F

RD
CM

CRD

PRD

Option IG F

RD

MOTORS

Motor
Type

WE
FU

FR

FV

RD
FW

FES

FS

PRD

RDD

HR

CRD PRDD CRDD DHR

[mm]

CHR

IG

IG F

RD/IG/IGF

CM

CM

CM

PRD

CRD

[in]

63S/L

11

12.5

23

16

4.84

0.47

6.02

1.06

3.94

1.54

2.20

3.46

6.22

5.24

1.46

71S/L

11

16.0

23

16

5.43

0.47

6.65

0.94

3.94

1.57

2.20

3.50

5.67

5.91

1.46

80S/L

14

21.5

30

20

6.14

0.63

7.20

1.22

3.94

1.93

2.40

3.54

5.51

6.69

1.57

90S/L

19

27.0

40

32

6.93

0.63

7.91

1.22

6.30

2.64

2.83

4.09

5.87

7.40

1.18

100L

24

31.0

50

40

7.64

0.63

8.86

1.10

6.30

2.95

2.71

3.74

6.10

8.27

1.10

112M

24

31.0

50

40

8.58

0.63 10.43 1.50

6.30

2.91

2.67

3.90

5.87

9.80

1.30

132S/M

32

41.0

80

18

70

10

10.12 0.71 12.51 1.61

7.87

4.57

2.48

4.53

6.10 11.81 0.98

* Consult Factory

148

G1142 - Subject to Change Without Notice

www.nord.com

Dimensions
Brakemotor Options

CRD

FV

CRDD

CHR

PRD

FU
FS

WE

RD

RDD

DHR

FR

FES

PRDD

FW

Standard
BRE

HR

CM

Option
BRE IG

CM

CRD

PRD

Option
BRE F

RD
CM

CRD

PRD

Option IG F
BRE IG F

MOTORS

RD

Motor
Type

WE
FU

FR

FV

RD
FW

FES

FS

PRD

RDD

HR

CRD PRDD CRDD DHR

[mm]

CHR

IG

IG F

RD/IG/IGF

CM

CM

CM

PRD

CRD

[in]

63S/L

11

12.5

23

3.5

16

4.84

0.47

6.02

1.02

0.39

1.69

2.44

3.54

4.92

5.24

1.46

71S/L

11

16.0

23

3.5

16

5.43

0.47

6.65

0.94

3.94

1.69

2.91

3.70

5.47

5.91

1.46

80S/L

14

21.5

30

20

6.14

0.63

7.20

1.22

3.94

1.97

2.20

3.50

5.47

6.69

1.57

90S/L

14

27.0

30

32

6.93

0.63

7.91

1.22

6.30

2.68

2.76

3.94

5.71

7.40

1.18

100L

24

31.0

50

10

40

7.64

0.63

8.86

0.87

6.30

3.07

2.80

4.13

5.52

8.27

1.10

112M

24

31.0

50

40

8.58

0.63 10.43 1.50

6.30

3.03

2.52

4.13

5.52

9.80

1.30

132S/M

32

41.0

80

10

70

10

10.12 0.71 12.60 1.61

7.87

4.25

2.56

4.92

6.10 11.81 0.98

* Consult Factory

www.nord.com

G1142 - Subject to Change Without Notice

149

Dimensions
Conduit Box & Cable Entry
L
X

XF

Type / Flange

Options

63S/L

FP

XA

AB

Outline dimensions

Cable entry

FP

AB

XF

XA

ce

ce-adapter

B14

5.12

4.53

0.47

3.94

7.56

3.94

2 M201.5

1/2 NPT

160S

5.12

4.53

0.63

3.94

7.72

3.94

2 M201.5

1/2 NPT

B14

BRE

5.12

4.84

0.71

5.28

9.76

3.50

2 M201.5

1/2 NPT

160S

BRE

5.12

4.84

0.87

5.28

9.92

3.50

2 M201.5

1/2 NPT

FP

AB

XF

XA

ce

ce-adapter

B14

5.71

4.88

0.79

3.94

8.43

3.94

2 M201.5

1/2 NPT

160S

5.71

4.88

1.65

3.94

9.29

3.94

2 M201.5

1/2 NPT

250S

5.71

4.88

1.42

3.94

9.06

3.94

2 M201.5

1/2 NPT

71S/L

B14

BRE

5.75

5.24

1.02

5.28

10.71

3.50

2 M201.5

1/2 NPT

160S

BRE

5.75

5.24

1.89

5.28

11.57

3.50

2 M201.5

1/2 NPT

250S

BRE

5.75

5.24

1.65

5.28

11.34

3.50

2 M201.5

1/2 NPT

80S/L/LH
MOTORS

FP

AB

XF

XA

ce

ce-adapter

B14

6.50

5.59

0.87

4.49

9.29

4.49

2 M251.5

3/4 NPT

160S

6.50

5.59

1.85

4.49

10.28

4.49

2 M251.5

3/4 NPT

250S

6.50

5.59

1.61

4.49

10.04

4.49

2 M251.5

3/4 NPT

B14

BRE

6.50

5.59

1.02

6.02

11.81

4.25

2 M251.5

3/4 NPT

160S

BRE

6.50

5.59

2.01

6.02

12.80

4.25

2 M251.5

3/4 NPT

250S

BRE

6.50

5.59

1.77

6.02

12.56

4.25

2 M251.5

3/4 NPT

FP

AB

XF

XA

ce

ce-adapter

B14

7.20

5.79

1.02

4.49

10.87

4.49

2 M251.5

3/4 NPT

160S

7.20

5.79

2.05

4.49

11.89

4.49

2 M251.5

3/4 NPT

250S

7.20

5.79

1.81

4.49

11.65

4.49

2 M251.5

3/4 NPT

300S

7.20

5.79

1.02

4.49

10.87

4.49

2 M251.5

3/4 NPT

90S/L/SH/LH

B14

BRE

7.20

5.79

1.18

6.02

13.82

4.25

2 M251.5

3/4 NPT

160S

BRE

7.20

5.79

2.20

6.02

14.84

4.25

2 M251.5

3/4 NPT

250S

BRE

7.20

5.79

1.97

6.02

14.61

4.25

2 M251.5

3/4 NPT

300S

BRE

7.20

5.79

1.18

6.02

13.82

4.25

2 M251.5

3/4 NPT

150

G1142 - Subject to Change Without Notice

www.nord.com

Dimensions
Conduit Box & Cable Entry
L
X

XF

Options

100L/L/LA/LH

Outline dimensions

Cable entry

FP

AB

XF

XA

ce

ce-adapter

B14

7.91

6.65

1.26

4.49

12.05

4.49

2 M321.5

1 NPT

160S

7.91

6.65

2.28

4.49

13.07

4.49

2 M321.5

1 NPT

250S

7.91

6.65

2.05

4.49

12.83

4.49

2 M321.5

1 NPT

300S

7.91

6.65

1.26

4.49

12.05

4.49

2 M321.5

1 NPT

250

7.91

6.65

1.26

4.49

12.05

4.49

2 M321.5

1 NPT

B14

BRE

7.91

6.77

1.42

6.02

15.63

4.25

2 M321.5

1 NPT

160S

BRE

7.91

6.77

2.44

6.02

16.65

4.25

2 M321.5

1 NPT

250S

BRE

7.91

6.77

2.20

6.02

16.42

4.25

2 M321.5

1 NPT

300S

BRE

7.91

6.77

1.42

6.02

15.63

4.25

2 M321.5

1 NPT

250

BRE

7.91

6.77

1.42

6.02

15.63

4.25

2 M321.5

1 NPT

112M/SH/MH

FP

AB

XF

XA

ce

ce-adapter

B14

8.98

7.05

1.77

4.49

12.83

4.49

2 M321.5

1 NPT

160S

8.98

7.05

2.91

4.49

13.98

4.49

2 M321.5

1 NPT

250S

8.98

7.05

2.68

4.49

13.74

4.49

2 M321.5

1 NPT

300S

8.98

7.05

1.89

4.49

12.95

4.49

2 M321.5

1 NPT

250

8.98

7.05

1.77

4.49

12.83

4.49

2 M321.5

1 NPT

B14

BRE

8.98

7.17

1.93

6.02

16.50

4.25

2 M321.5

1 NPT

160S

BRE

8.98

7.17

3.07

6.02

17.64

4.25

2 M321.5

1 NPT

250S

BRE

8.98

7.17

2.83

6.02

17.40

4.25

2 M321.5

1 NPT

300S

BRE

8.98

7.17

2.05

6.02

16.61

4.25

2 M321.5

1 NPT

250

BRE

8.98

7.17

1.93

6.02

16.50

4.25

2 M321.5

1 NPT

132S/M/SH/MH

FP

AB

XF

XA

ce

ce-adapter

B14

10.47

8.03

2.09

4.80

16.42

4.80

2 M321.5

1 NPT

250S

10.47

8.03

2.80

4.80

17.13

4.80

2 M321.5

1 NPT

300S

10.47

8.03

2.01

4.80

16.34

4.80

2 M321.5

1 NPT

250

10.47

8.03

2.80

4.80

17.13

4.80

2 M321.5

1 NPT

B14

BRE

10.47

7.91

1.77

7.28

20.59

5.47

2 M321.5

1 NPT

250S

BRE

10.47

7.91

7.28

7.28

21.34

5.47

2 M321.5

1 NPT

300S

BRE

10.47

7.91

1.73

7.28

20.55

5.47

2 M321.5

1 NPT

250

BRE

10.47

7.91

2.52

7.28

21.34

5.47

2 M321.5

1 NPT

www.nord.com

G1142 - Subject to Change Without Notice

151

MOTORS

Type / Flange

FP

XA

AB

Dimensions
SK 300E Trio AC Vector Drive
Motor Dimensions with SK 300E Motor Mounted AC Vector Drive
TW

AB1

TL

240 VAC Input AC Vector Drive

480 VAC Input AC Vector Drive

Basic NORD

Power

Motor

Rating

Type

AC Vector

AB1

Type

AC Vector

AB1

Description

HP/kW

SK 300E

Drive Size

[in]

SK 300E

Drive Size

[in]

63S/4

0.16 / 0.12

-370-323-B

Size 1

7.48

-550-340-B

Size 1

7.48

63L/4

0.25 / 0.18

-370-323-B

Size 1

7.48

-550-340-B

Size 1

7.48

MOTORS

71S/4

0.33 / 0.25

-370-323-B

Size 1

7.78

-550-340-B

Size 1

7.78

71L/4

0.50 / 0.37

-370-323-B

Size 1

7.78

-550-340-B

Size 1

7.78

80S/4

0.75 / 0.55

-550-323-B

Size 1

7.42

-550-340-B

Size 1

7.42

80L/4

1.00/ 0.75

-750-323-B

Size 1

7.42

-750-340-B

Size 1

7.42

90S/4

1.50/ 1.1

-111-323-B

Size 2

8.69

-111-340-B

Size 1

7.62

90L/4

2.00/ 1.5

-151-323-B

Size 2

8.69

-151-340-B

Size 1

7.62

100L/4

3.00/ 2.2

-221-323-B

Size 2

9.19

-221-340-B

Size 2

9.19

100LA/4

5.00/ 3.7

Not Available

N/A

N/A

-401-340-B

Size 2

9.19

152

AC Vector Drive

TL

TW

Weight

Size

[in]

[in]

[lbs]

Size 1

8.43

6.14

8.8

Size 2

11.14

7.72

18.5

G1142 - Subject to Change Without Notice

www.nord.com

Brakes
Brakes
Operation
Selection-Torque
Rectiers
Selection-Performance
Mechanical Options
Connection Diagrams

DRIVESYSTEMS

www.nord.com

G1142 Subject to Change Without Notice

153

General
Information
Motor-Brake Option (BRE)
The standard NORD motor brake is spring-set when
power is removed from the brake circuit (power-off).
The brake coil utilizes a DC voltage supplied through
a rectied power source.
Advantages
Each NORD motor frame size has a number of
brake sizes available, with different torque
capacities.
Brake adjustment is possible by changing the brake
spring combinations. In addition, several common
brake sizes also have an additional spanner-nut
adjustment available.
Compared to the many AC brakes on the market,
NORD brakes offer better wear capacity, easier
eld adjustability, greater reliability, and lower
end-cost to the consumer.
NORD motor-brakes operate with a high degree
of safety, because the brake is actively engaged
with the no brake supply voltage (power-off).
The rotating brake disc is environmentally safe
with an asbestos-free friction material bonded to
each side.
The connection between the rectier and the
brake coil is already completed at the factory.
The brake air-gap is factory-set but can easily be
adjusted in the event of wear.
BRAKES

Operation
The main AC supply power to the brake rectier can
be supplied from either the motor terminal board or
from a separately switched power source.
In typical direct-across-the-line motor operation,
AC brake power may be supplied from the motors
terminal board.
If the motor is a two-speed model, or if the motor
is being controlled by a variable frequency drive or
electrical soft-start, then the brake rectier must
be powered from a separate AC source.
When the brake is de-energized (Power off), the
braking springs exert a force against the armature
plate (pressure plate), preventing the brake rotor
from rotating. Conversely, when the brake coil is
energized (Power on), a magnetic eld builds and
pulls the armature plate across the air gap to the
brake oil casing. This action frees the brake rotor
and allows the motor shaft to rotate.

154

Brake Selection
The selection of a motor brake system is broken
down into ve phases. The selection of the braking
torque, the selection of the braking times (release
times and setting times), the selection of the electrical supply and connection, the selection of brake
options, and the nal phase is the verication of the
permissible brake work.
Selection steps
1) Brake torque (page 156)
2) Brake times (page 160)
3) Electrical supply and connection (page 161)
4) Brake options (page 163)
5) Brake work verication (page 168)

G1142 Subject to Change Without Notice

www.nord.com

General
Information
Brake Options
Abbreviation

Description

Page

ADJ

Torque Adjustment - Brake torque may be adjusted at the factory

157

BIP66

IP66 Brake Enclosure - Brake with IP66 enclosure

163

BSH

Brake Heating/Bifilar Coil - Provides a seperate coil for heating to avoid condensation

163

DBR

Double Brake (2xBRE) - Double brakes are used for redundancy and additional safety

166

FBR

Brass Foil - Provides a brass foil in the brake air-gap to provide faster braking times

164

FHL

Locking Hand Release Lever - Lockable manual hand release lever

163

HL

Hand Release Lever - Manual hand release lever

163

HLH

Hand Release Lever with Hole - Hand lever with 5.5mm hole

163

IR

Current Sensing Relay - Fast brake engagement (stopping) without external control equipment

165

MIK

Micro-Switch - Brake tted with a micro-switch for sensing the brake state (released or engaged)

164

NRB1

Quiet Brake Release - An o-ring is placed between the coil body and the armature plate for noise reduction

164

NRB2

Quiet Brake Motor Operation - An o-ring is placed between the carrier hub & the armature plate to prevent
clattering.

164

RG

Corrosion Protected Brake - Corrosion protected brake

163

SR

Dust & Corrosion Protected Brake - Dust & corrosion protected brake

163

Rectifier Options
Abbreviation

Description

Page

Rectifiers

Most NORD brakes are provided with a rectier that converts AC voltage to DC voltage. Rectiers are
used because most motors are AC powered, but brakes require DC power.

158

G...V

Sealed Rectifier - Rectiers sealed with an electrically safe resin

158

GP...

High Performance Rectifier - Improves brake release and stopping times

159

Brake Nomenclature

BRAKES

BRE

Additional Brake Options


Brake Size/Torque Rating
Brake

Ordering Examples
BRE 100 HL

BRE 40

RG IR

FHL SR

Current Sensing Relay


Dust & Corrosion Prot. Brake

Corrosion Protected Brake

Locking Hand Release Lever

Hand Release Lever

40 Nm Brake Torque

100 Nm Brake Torque

Brake

Brake
Brake, 100 Nm with a hand release lever, corrosion
protected brake, and a current sensing relay.

www.nord.com

Brake, 40 Nm with a locking hand release lever and


dust & corrosion protected brake.

G1142 Subject to Change Without Notice

155

General
Information
Brake Torque Selection

General Selection Considerations

Each NORD motor size has a number of brake torque


sizes available. The bold value in the table below is
the standard brake torque size for each motor.

NORD relies on the equipment builder to specify appropriate brake sizing for their application, while
giving consideration to the following:
For most applications, we advise sizing the brake to
1.5 - 2 times the motor rated torque.
For vertical applications, it may be advisable to size
the brake size up to 3 times the motor rated
torque.
For some applications, it may be necessary to specify
a reduced brake torque setting to prevent, excessive
peak load conditions developed at the reducer
output.
On travel drive applications, excessive brake torque
may lead to wheel skid, and excess hoist-cable
swing.

Example for ordering: SK 32 - 80S/4 BRE 10


(BRE 10 indicates the unit has a brake torque size of 10 Nm)

Motor
Frame
63S/L
71S/L
80S
80L
90S
90L
BRAKES

100L
100LA/4
112M
132S
132M
+ weight
+ inertia

Units
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
Nm
lb-ft
kg
lb
2
kgm x 10-3
lb-ft2 x 10-3

BRE5
5
3.7
5
3.7
5
3.7
5
3.7

2
4.4
0.15
0.356

BRE10
10 *1)
7.4 *1)
10 *
7.4
10
7.4
10
7.4
10
7.4
10
7.4

3
6.6
0.45
1.07

BRE20

Brake Size
BRE40

20 *
15 *
20 *
15 *
20
15
20
15
20
15
20
15
20
15

40 *
30 *
40 *
30
40
30
40
30
40
30

5.5
12.1
0.153
3.63

7
15.4
0.45
10.7

* BIP66 IP66 brake not possible.


1) Brake release lever HL and FHL not possible.
2) When used as a stopping brake, evaluation of brake work is essential.
3) Designed as holding brake or emergency stop brake only.

156

G1142 Subject to Change Without Notice

BRE60

BRE100

BRE150

60 * 1)
44
60 * 1)
44 * 1)
60
44
60
44
60
44

100
74
100
74

150 * 1)
110 * 1)
150 * 1)
110 * 1)

10
22
0.86
20.4

16
35
1.22
29.0

22
49
2.85
67.7

1 Nm = 0.738 lb-ft
1 lb-ft = 1.36 Nm
www.nord.com

General
Information
Torque Adjustment (ADJ)

Mod

The brake torque can be adjusted by changing the brake spring combinations. Additionally, on brakes up to size BRE40, the user can can make ne torque adjustments
by turning the spanner nut. From the factory, the spanner nut will be tight against the
brake casing. The braking torque is adjusted by unscrewing the spanner nut a number
of clicks with a spanner wrench.

When Ordering the Torque Adjustment option


specify ADJ

Nm

Torque Spring Adjustments

8
7
6
5
4
3

Unit

BRE5

BRE10

BRE20

BRE40

BRE60

BRE100

BRE150

[Nm]

10

20

40

60

100

150

[lb-ft]

3.7

7.4

14.8

29.5

44.3

74

111

[Nm]
[lb-ft]

[Nm]
[lb-ft]
[Nm]

3.5

14

28

43

70

107

[lb-ft]

2.6

5.2

10.3

20.7

31.7

51.6

79.0

[Nm]

12

23

34

57

85

[lb-ft]

2.2

4.4

8.9

17.0

25.1

42.0

62.7

[Nm]

17

26

42

65

[lb-ft]

1.5

3.0

5.9

12.5

19.2

31.0

47.9

Reduction of Brake Torque with Spanner Nut


Torque Reduction per Spanner Nut Click
(Adjustment Step)
Lowest Torque Setting

Unit

BRE5

BRE10

BRE20

BRE40

[Nm]

0.2

0.2

0.3

1.0

[lb-ft]

0.15

0.15

0.22

0.74

[Nm]

0.8

1.6

4.4

5.0

[lb-ft]

0.59

1.18

3.25

3.69

WARNING
Brake torque - The brake torque is measured with a mean friction radius of the brake pad surface
with a circumferential speed of 1m/sec (197 fpm).
Brake torque tolerance - For different applications and operating conditions, brake torque can vary from
+40/-20% compared to the rated brake torque.
Initial operation & wear in period - In new condition, the brake will have a reduced torque of up
to 30%. In order to achieve full rated brake torque, a short break in period is required. The break in time
will vary depending on system loads.
Setting times - The lower the brake torque, the longer the brake setting times.
Release times - The lower the brake torque, the faster the brake release times.

www.nord.com

G1142 Subject to Change Without Notice

157

BRAKES

# Springs

General
Information
Brake Control Rectiers
NORD brake control rectiers convert AC voltage to
DC voltage. Rectiers are used because most applications require AC voltage to power the motor, but
DC power is required to power the brake and DC
power is not typically available.

Rectier Nomenclature
G H E 4 0 L
Electronic Protection
L = Varnish coated
V = Encapsulated

NORD brakemotors include the rectier located


inside the terminal box. NORD rectiers have six
terminals and can be powered by the motor terminal
block, or by a separate power source.

Components Current Rating


0 = 0.5A (75C)
1 = 1.5A (75C)
Voltage Range
2 = up to 275VAC input
4 = up to 480VAC input
5 = up to 575VAC input
Type of DC Switching
E = External DC-switching (contact)
U = Internal DC-switching (voltage)

Rectier Terminals

Type of Rectier
H= Half-wave
V = Full-wave (bridge)
P = Push-Hybrid (full & half-wave)

Description

1&2

Brake Supply AC Voltage

3&4

DC-Switching Contact or Jumper

5&6

Connection to Brake Coil

Rectier

BRAKES

Rectier Advantages:

Standard Rectier

Individual power source for each brake


Compact size, mounted inside the terminal box
Multiple voltage options, types, and
release/engagement modes available
Mountable in remote control cabinet
Integral protection against voltage spikes

NORD standard rectiers are provided with each


brake motor (except 24V DC brakes) unless a sealed
or high performance rectier is specied.
Standard Rectier
Nomenclature

Part #

Type

Color

Rectier Types:

GVE20L

19141000

Full-wave

Black

Full-wave rectier: The DC output voltage is 90%


of the applied input AC voltage types GV

GHE40L

19141010

Half-wave

Yellow

GHE50L

19141020

Half-wave

Gray

Half-wave rectier: The DC output voltage is 45% of


the applied input AC voltage types GH

Sealed Rectiers GV

Push-hybrid rectier (full-wave and half-wave): The


rectier is designed to switch from an initial
full-wave mode to a nal half-wave mode in
approximately 250 ms types GP

NORD offers rectiers that are sealed with an electrically safe resin to ensure that water and moisture
will not pass into the rectier. Sealed rectiers have
the same brake performance ratings as the standard
rectier and can be benecial if water is present in
the motors terminal box.
Sealed Rectier
Nomenclature

158

Part #

Type

Color

GVE20V

19141030

Full-wave

Black

GHE40V

19141040

Half-wave

Yellow

GHE50V

19141050

Half-wave

Gray

G1142 Subject to Change Without Notice

www.nord.com

General
Information
AC Switching (Standard Stopping)
The rectier can be wired to operate by supplying and
removing AC power, commonly called AC switching.
The advantage to using AC switching is that the
rectier can be powered directly from the motors
terminal block and no additional wiring is required.
However, tapping into the motors terminal block
gives the slower stopping time due to the de-energizing time of the motors magnetic eld. The stopping
time can be improved by wiring the rectier from an
external power supply.

motor or soft-starter. The GPU rectiers are not


suitable for use when the brake power is taken form
the motor supply power (motor terminal block).
There are two ways to apply GP rectiers. The
rst is called, overexcitation (fast brake release) and
the second is called, reduced power holding (very
fast stopping)
GPE - High Performance Rectier
with External DC switching
Nomenclature

Part #

Type

Color

GPE20L

19140230

Push-hybrid

Black

GPE40L

19140240

Push-hybrid

Black

GPU - High Performance Rectier


with Integrated DC switching
Nomenclature

DC switching directly interrupts the current ow in the


DC circuit of the rectier. This provides much faster
stopping, because you do not need to wait for the
motors magnetic eld to de-energize. To implement
DC switching, a normally open relay must be installed
between terminals 3 and 4 on the rectier for rectier
types GVE, GHE, and GPE. For GPU type rectiers
simply remove the jumper between terminals 3 & 4 to
activate DC switching.

GVE/GHE/GPE

GPU

AC BRAKE
VOLTAGE

GP... High Performance Rectiers


The GP high performance rectiers improve
brake release time & stopping time. The GP.
rectier is a push-hybrid rectier; meaning that it
initially acts as a full-wave rectier for approximately
250 ms, after which it operates as a half-wave rectier.
There are two types of GP rectiers. The rst type
utilizes External DC Switching GPE..., this is primarily
used in across-the-line applications, where the brake
power is supplied from the motor terminal block. The
second type utilizes Integrated DC Switching GPU....
The built-in DC switching of the GPU rectiers is
supply voltage triggered. The GPU rectiers can
only be used when the brake is powered separately
from the motor. Examples include using an AC vector
drive, two-speed

www.nord.com

Part #

Type

Color

GPU20L

19140090

Push-hybrid

Black

GPU40L

19140170

Push-hybrid

Black

Overexcitation (fast brake release)


In overexcitation, the rectier initially over-voltages
(overexcites) the brake coil, causing a stronger than
normal magnetic eld which releases the brake quicker
than normal. The rectier then is switched to a lower
holding voltage so it does not thermally overload the
brake coil. In this method, the brake coil is selected as if
the brake system is powered by a half-wave rectier. In
other words, the DC brake voltage should be 45% of the
applied AC rectier input voltage. This brake control is
also sometimes referred to as Voltage Forcing or Supercharging.
Overexcitation is commonly used in very high cycling
brakemotor applications to reduce motor heating
during the motor start and brake release.

Reduced Power Holding (very fast stopping)


In reduced power holding, the rectier initially supplies
the rated DC voltage to the brake coil. When voltage
is rst applied, the rectier operates as a full-wave
rectier (90% of the applied AC voltage), releasing the
brake in the standard time. After the brake is released,
the rectier switches to half-wave mode (45% of the
applied DC voltage), weakening the brakes magnetic
eld. The weaker eld will allow the brake to stop more
quickly when power is removed. In this method the
brake coil is selected as if the brake system is powered
by a full-wave rectier. Therefore, the brake coils DC
voltage rating should be 90% of the AC voltage applied
to the rectier.

G1142 Subject to Change Without Notice

159

BRAKES

DC switching (Fast Stopping)

Selection
Brake Times & Electrical Selection

Selection Suggestions

Brake timing performance is critical in selecting the


optimal brake system. NORD brakes can provide exceptional performance in terms of the release (start)
times and engagement (stop) times. Use the following guidelines in order to select the correct brake
control components and connections.

When Fast or Very Fast Stopping is Recommended

1) Determine if the brake needs to be wired directly


from the motor terminal block or powered by a separate source.
- If you are using an AC vector drive, soft-start or a
two speed motor you will need to supply the rectier
from a separate power source.
- If the motor is powered direct across-the-line the
rectier power can be supplied from the motors terminal block.
2) What type of performance do I need?
- Is the standard brake performance OK?
- Is a higher performance required for fast brake
release or very fast brake stopping?

Power Source

BRAKES

Motor
Terminal Block

Separate
Power Source

Any applications that require quick stops and positive action at stand-still
conveyors and inclined conveyors
hoists and lifts
bulk material handling equipment
(bucket elevators, idler conveyors).

WARNING
Hoisting (lifting/lowering) applications - must
have the brake wired for fast response.
When Fast-Release is Recommended (Overexcitation)
Any application that is very high-cycling with frequent starts and stops. These applications require
the brake to release very-quickly in order to avoid excessive heat build-up in the AC motor and brake coil.
Index conveyors
Diverters
Storage and retrieval crane systems

Brake Release
(start)

Brake engagement
(stop)

Braking Method

Rectier

Standard

Standard (AC switching)

10*

GV/GH

Standard

Fast (DC switching)

15*

GV/GH

Standard

Very Fast (Reduced power holding)

40*

GPE

Fast (Overexcitation)

Standard (AC switching)

30*

GPE

Fast (Overexcitation)

Fast (DC switching)

35*

GPE

Standard

Standard (AC switching)

20*

GV/GH

Standard

Fast (DC switching)

25*

GV/GH

Standard

Very Fast (Reduced power holding)

55*

GPU

Fast (Overexcitation)

Standard (AC switching)

45*

GPU

Fast (Overexcitation)

Fast (DC switching)

50*

GPU

* Braking methods referenced in connection diagrams on pages 169 - 174

160

G1142 Subject to Change Without Notice

www.nord.com

Selection
3) What is the AC brake supply voltage?

AC Brake
Supply Voltage (VAC)
115
(105-120)

208
(200-208)

230
(220-240)

400
(380-415)

460
(440-480)

500

575
(550-600)

Braking
Method

Rectier
Model Type

DC Brake
Voltage (VDC)

Rectier
Part Number

20
25
10
15
20
25
40
55
10
10
15
15
20
20
25
25
30
35
40
45
50
55
10
15
20
25
10
15
20
25
30
35
45
50
10
15
20
25
10
15
20
25

GVE20L
GVE20L
GVE20L
GVE20L
GVE20L
GVE20L
GPE20L
GPU20L
GVE20L
GHE40L
GVE20L
GHE40L
GVE20L
GHE40L
GVE20L
GHE40L
GPE20L
GPE20L
GPE20L
GPU20L
GPU20L
GPU20L
GHE40L
GHE40L
GHE40L
GHE40L
GHE40L
GHE40L
GHE40L
GHE40L
GPE40L
GPE40L
GPU40L
GPU40L
GHE50L
GHE50L
GHE50L
GHE50L
GHE50L
GHE50L
GHE50L
GHE50L

105
105
180
180
180
180
180
180
205
105
205
105
205
105
205
105
105
105
205
105
105
205
180
180
180
180
205
205
205
205
205
205
205
205
225
225
225
225
250
250
250
250

19141000
19141000
19141000
19141000
19141000
19141000
19140230
19140090
19141000
19141010
19141000
19141010
19141000
19141010
19141000
19141010
19140230
19140230
19140230
19140090
19140090
19140090
19141010
19141010
19141010
19141010
19141010
19141010
19141010
19141010
19140240
19140240
19140170
19140170
19141020
19141020
19141020
19141020
19141020
19141020
19141020
19141020

Specify Rectier Model Type

www.nord.com

BRAKES

The table below determines the rectier and DC brake voltage required, based on the AC supply voltage & braking method.

And DC Brake Voltage

G1142 Subject to Change Without Notice

161

Rectifier Ratings
& Dimensions
Standard Rectier Dimensions

0.24 in
6.0 mm

GP Rectier Dimensions

0.14 in
3.5 mm

0.14 in
3.5 mm

0.14 in
3.5 mm

0.20 in
5.0 mm
1.50 in
38.0 mm

0.14 in
3.5 mm

0.20 in
5.0 mm
1.95 in
49.5 mm

1.06 in
27.0 mm
0.75 in
19.0 mm

1.89 in
48.0 mm

1.46 in
37.0 mm

0.16 in
4.0 mm

2.34 in
59.5 mm

1.54 in
39.0 mm

0.12 in
3.0 mm

Rectier Overview
Rectier
Model Type

Part
Number

Part Type 1 input


Voltage
Color

Input Voltage
Range

Output Voltage

Rated Output DC switching


Current
Mode
(40C) (75C)

Standard Protected Electronics L

BRAKES

GVE20L
Full-Wave

19141000

Black

230VAC

110-275VAC +/- 10%

205VDC (VDC = VAC X 0.9)

1.5ADC 1.0ADC

External
Contact

GHE40L
Half-Wave

19141010

Yellow

480VAC

230-480VAC +/- 10%

216VDC (VDC = VAC X 0.45)

1.0ADC 0.5ADC

External
Contact

GHE50L
Half-Wave

19141020

Grey

575VAC

500-575VAC +/- 10%

259VDC (VDC = VAC X 0.45)

1.0ADC 0.5ADC

External
Contact

GPE20L
Push-Hybrid

19140230

Black

230VAC

200-275VAC +/- 10%

205VDC / 105VDC
0.7ADC 0.5ADC
(VDC = VAC X 0.9) / (VDC = VAC X 0.45)

External
Contact

GPE40L
Push-Hybrid

19140240

Black

480VAC

380-480VAC +/-10%

432VDC / 216VDC
1.0ADC 0.5ADC
(VDC = VAC X 0.9) / (VDC = VAC X 0.45)

External
Contact

GPU20L
Push-Hybrid

19140090

Black

230VAC

200-275VAC +/- 10%

205VDC / 105VDC
0.7ADC 0.5ADC
(VDC = VAC X 0.9) / (VDC = VAC X 0.45)

Internal
Activation*

GPU40L
Hybrid

19140170

Black

480VAC

380-480VAC +/-10%

432VDC / 216VDC
1.0ADC 0.5ADC
(VDC = VAC X 0.9) / (VDC = VAC X 0.45)

Internal
Activation*

Rectier Electronics Protected with Potting Option V


GVE20V
Full-Wave

19141030

Black

230VAC

110-275VAC +/- 10%

205VDC (VDC = VAC X 0.9)

1.5ADC 1.0ADC

External
Contact

GHE40V
Half-Wave

19141040

Yellow

480VAC

230-480VAC +/- 10%

216VDC (VDC = VAC X 0.45)

1.0ADC 0.5ADC

External
Contact

GHE50V
Half-Wave

19141050

Grey

575VAC

500-575VAC +/- 10%

259VDC (VDC = VAC X 0.45)

1.0ADC 0.5ADC

External
Contact

* Voltage based - deactivated with a jumper between terminals 3 & 4

162

G1142 Subject to Change Without Notice

www.nord.com

Options
Hand Release Lever (HL)

Mod

The hand release option allows the brake to be


manually released without requiring that the brake
be energized with voltage. The lever has a spring
return that allows the brake to be hand released and
returned automatically to its set position. The hand
release lever can be unscrewed for easy removal.

Corrosion Protected Brake (RG)

Build

The brake is tted with a stainless steel brake plate


to provide additional corrosion protection in severe
and wet environments.

Dust & Corrosion


Protected Brake (SR)

Build

A rubber-sealing boot is installed on the brake to


provide additional protection in dusty environments.
This feature includes the stainless steel brake plate
(RG).

Dust Boot
Stainless Steel
Brake Plate

Locking Hand Release Lever (FHL)

Mod

This option allows the brake to be manually released


and locked off without requiring voltage to the
brake. The lock mechanism prevents the spring from
returning the brake to a closed state without manual
action by the user. The hand release lever can be
unscrewed for easy removal.

IP66 Brake Enclosure (BIP66)

Build

Brake Heating / Bilar Coil (BSH)

Build

Brakes can be provided with a circuit to heat the brake


while the motor and brake are inactive (at rest). This
is accomplished via a second coil in winding in the
brake. This coil is opposite in polarity (bilar) as the
main brake coil so when current passes through both
coils, no net magnetic eld is created only heat.

Hand Release Lever With Hole (HLH)

Build

The hand release levers can be provided with a 5.5mm


through hole. The hole can be used for attaching
external pulling devices such as a cord to release the
brake at a distance. This option is available for brake
sizes BRE5 to BRE60.

www.nord.com

Warning Heating the brake with full operation


voltage is only possible at temperatures below
freezing (32F / 0C). If heating is also required above
freezing then reduced operating voltage is required.

G1142 Subject to Change Without Notice

163

BRAKES

A sealed brake with IP66 enclosure protection can


also be provided. This brake has a different mechanical housing that provides a higher degree of protection against severe environments.

Options
Quiet Brake Release (NRB1)

Build

To reduce the noise of the brake release, an o-ring


can be placed between the brake coil body and the
armature plate (stationary disc). The o-ring dampens
the impact caused by the armature plate hitting the
brake coil body during the release process. When
ordering NRB1, the SR (Dust Boot) option is required.
The SR option also includes the RG stainless steel
corrosion plate.

Quiet Brake Motor Operation (NRB2)

Dust Boot (SR)


Needed for NBR1

Corrosion Protection (RG)


Included in SR

Build

The micro switch monitors the release state of the


brake and can be wired into external control circuitry
to provide additional safety. The switch can also
be used to detect certain brake service problems
including excessive brake wear.

Build

Noise due to vibration in the brake components is


possible during motor operation particularly with
variable frequency drive or single phase motor
operation. To reduce this vibration the brake can
be constructed with an o-ring between the brake
carrier hub and the armature plate. This o-ring will
prevent the clattering caused by the rapid micro
speed changes in the motor caused by or single phase
operation.

NBR1

Micro Switch (MIK)

Brass Foil (FBR)

Build

NORD brakes can be tted with a brass foil in between the armature plate and the brake coil body.
The foil acts as a magnetic resistance to weaken the
brake coils magnetic attraction to the armature
plate. The weaker magnetic attraction between the
armature plate and the brake coil will provide faster
brake reaction (stopping) times. The brake release
(start) times will be increased. The brass foil is normally used in combination with the fast GP rectiers
in over excitation mode.
Brass Foil (FBR)

Brass Foil (FBR)

BRAKES

NBR2

164

G1142 Subject to Change Without Notice

www.nord.com

Options
Current Sensing Relay (IR)

Mod

The current sensing relay, normally called the IR


option, is used to achieve improved brake engagement or stopping time without the use of external
control equipment or additional wiring. The relay is
mounted directly onto the motor terminal box. The
relay switch leads are connected to terminals 3 and
4 of the rectier. When the power to the motor is
shut off, the IR relay opens the brake circuit on the
DC side; this allows the brake to demagnetize quickly.

WARNING
Requirements
Motor must be powered across-the-line (not
inverter powered or controlled with a soft-start)
The brake power must be provided from the
motors terminal block (not separately powered)
Motor must be a single-speed (not possible with
two-speed motors)

Ratings
18556010

18556020

Motor Frame Sizes

63S - 180M*

180L - 225M

AC Input Current
- black/white wires

25AAC
75AAC - 0.2 s

50 AAC
75 AAC - 0.2 s

DC Brake Current
- red/blue wires

2.0 ADC

2.0 ADC

Additional Brake
Setting Delay

18 ms

18 ms

- 40 to 75 C
- 40 to 167 F

- 40 to 75 C
- 40 to 167 F

IP65

IP65

Ambient Temperature
Enclosure Rating

BRAKES

Part number

* For 180MX motor frame at 230/460V use part number 18556020

Connection Notes
Rectier

IR-Relay Wires
to Rectier

Model
Type

Part
Number

Design

Red

Blue

GVE20L

1914000

Full-wave

Thread

Motor Frame

Part Number

63-71

18542006*

Conduit Box Thread Adapter

GHE40L

19141010

Half-wave

M20

GHE50L

19141020

Half-wave

M25

80-90

18522253

GPE20L

19140230

Push-hybrid

M32

100-132

18522320

GPE40L

19140240

Push-hybrid

M40

160-180

18522400 + 18522253

* Spacer

www.nord.com

G1142 Subject to Change Without Notice

165

Options
Double Brakes (DBR)

Build

Some applications require two independent brakes to


meet industry safety guidelines.

Double Brakes for Theatrical Applications


Many international standards for braking systems
used on theatre hoists mandate the use of brakes
that automatically set when power is removed. Redundancy is also required with the system brakes. If
one brake fails, the other brake can still operate the
system by running independently and parallel to each
other. NORD DBR (2xBRE) brake systems are designed
to meet these requirements. The NORD double brakes
are also designed for quiet operation < 50dB(A).

WARNING
NORD recommends delayed operation of one of the
brakes. If the brakes are operated simultaneously, the combined torques may result in
excessive torque for the gear unit or other
mechanical system elements. If the brakes are set
at the same time even in an E-stop condition, the
gear units must be sized to handle this increased
torque.

Some safety standards require that the load brake


hold 1.25 times the rated load at test. We recommend
selecting the brake for approximately 1.6 to a
maximum of 2.0 times the required operating torque
for each brake.
The NORD double theatre brakes do not need to be
worn-in and will achieve their full braking torque
initially.
Two brake rectiers are required for operating a
double brake system. These will be provided as loose
parts and are normally mounted in the customers
control panel.
The double brake option will add motor length
compared to the single brake.
BRAKES

Motor

Brake

63S/L
71S/L
80S
80L
90S
90L
100L
110L/40
112M
132S
132M

DBR6
DBR6
DBR6
DBR12
DBR12
DBR25
DBR25
DBR50
DBR50
DBR75
DBR125

166

7 Springs
[Nm]
[lb-ft]
2x6
2 x 4.4
2x6
2 x 4.4
2x6
2 x 4.4
2 x 12.5
2 x 9.2
2 x 12.5
2 x 9.2
2 x 25
2 x 18.4
2 x 25
2 x 18.4
2 x 50
2 x 37
2 x 50
2 x 37
2 x 75
2 x 55
2 x 125
2 x 92

5 Springs
[Nm]
[lb-ft]
2x4
2x3
2x4
2x3
2x4
2x3
2 x 8.5
2 x 6.3
2 x 8.5
2 x 6.3
2 x 17.5
2 x 12.9
2 x 17.5
2 x 12.9
2 x 35
2 x 26
2 x 35
2 x 26
2 x 52
2 x 38
2 x 89
2 x 66

G1142 Subject to Change Without Notice

4 Springs
[Nm]
[lb-ft]
2 x 3.5
2 x 2.6
2 x 3.5
2 x 2.6
2 x 3.5
2 x 2.6
2x7
2 x 5.2
2x7
2 x 5.2
2 x 14
2 x 10.3
2 x 14
2 x 10.3
2 x 28
2 x 20.7
2 x 28
2 x 20.7
2 x 42
2 x 31
2 x 70
2 x 52

www.nord.com

Performance
Data
Detailed Brake Performance Data

Brake torque max


Power coil P20
Nominal air gap
Maximum air gap
(re-adjust) amax
Max brake pad wear must be replaced
Minimum brake
pad thickness

BRE5

BRE10

BRE20

BRE40

BRE60

BRE100

BRE150

[lb-ft]

3.7

7.4

15

30

44

74

110

[lb-in]

44

89

177

354

531

885

1330

[Nm]

10

20

40

60

100

150

[W]

22

28

39

42

50

75

76

[in]

0.008

0.008

0.008

0.012

0.012

0.016

0.020

[mm]

0.2

0.2

0.2

0.3

0.3

0.4

0.5

[in]

0.024

0.013

n/a *

0.035

0.039

0.043

0.043

[mm]

0.6

0.8

n/a *

0.9

1.0

1.1

1.1

[in]

0.118

0.118

0.039

0.118

0.138

0.138

0.138

[mm]

3.5

3.5

3.5

[in]

0.177

0.217

0.295

0.374

0.453

0.492

0.571

[mm]

4.5

5.5

7.5

9.5

11.5

12.5

14.5

Max work per cycle Wrmax

[Jx103]

12

25

35

50

75

Work until re-adjust Wrn

[Jx107]

12

20

35

60

125

200

Heat load per cycle

[J/s]

80

100

130

160

200

250

300

Release time (start) t1

[ms]

35

45

70

80

120

160

200

Release time (start) t1-OE

[ms]

15

15

28

28

75

110

110

Setting time (stop) t2-AC

[ms]

70

95

140

175

210

280

350

Setting time (stop) t2-DC

[ms]

30

45

30

75

90

120

150

Setting time (stop) t2-DCRP

[ms]

11

12

12

13

17

IR relay delay (stop) t2-IR

[ms]

18

18

18

18

18

18

18

Current 250VDC coil

[A]

0.09

0.11

0.16

0.18

0.19

0.31

0.31

Current 225VDC coil

[A]

0.09

0.13

0.18

0.20

0.22

0.35

0.36

Current 205VDC coil

[A]

0.11

0.13

0.22

0.24

0.28

0.44

0.45

Current 180VDC coil

[A]

0.12

0.16

0.21

0.25

0.30

0.46

0.47

Current 105VDC coil

[A]

0.21

0.32

0.36

0.46

0.60

0.88

0.89

Current 24VDC coil

[A]

0.92

1.17

1.63

1.75

2.08

3.10

3.20

Release times
t1 Brake release time - Standard
t1-OE Brake release time Overexcitation (GP)

Set (stop) times


t2-AC Brake set time AC switching
t2-DC Brake set time DC switching
t2-DCRP Brake set time DC switching reduced power
t2-IR Additional brake stopping of the IR relay
An increased air gap will alter the braking times.

www.nord.com

G1142 Subject to Change Without Notice

167

BRAKES

Brake Size

Brake
Calculations
Brake Size Calculation

Abbreviation Key

Torque and inertias below are based on the motor speed.


Load side torques must always be divided by the gear
reduction ratio. Inertias must be divided by the square
of the gear ratio. You must also consider any external
reduction ratio outside the gearbox.

c/h

Number of brakes per hour

J [lb-ft2]

Inertia

Jmotor [lb-ft ]

Motor inertia

TB [lb-in]

System reduction ratio


Safety factors. Based on application and
according to industry rules and practices
Hoisting >2
Hoisting with people >2..3
Travel drives 0.5 to 1.5
Brake torque

Tdyn [lb-in]

Dynamic torque

Selection for holding loads (static)

Treq = Tstat = Tload K


Selection for stopping loads (static + dynamic)

Jload

J = Jmotor +

Typically other inertias, like the gearbox, can be ignored.

Jn
Tdyn =
25.7 tr
Treq = (Tdyn + Tload ) K

Treq [lb-in]

Required brake torque

Tload [lb-in]

Load torque

Tstat [lb-in]

Static torque

n [rpm]

Motor speed

tr [sec]

Stopping time

W [J]

Brake work

Wmax [J]

Maximum brake work for one brake


operations

For driving loads use: Tload


For overhauling loads use: +Tload

Brake Work Verification

J n2

5880

TB
TB + Tload

W < Wmax

For driving loads use: +Tload


For overhauling loads use: Tload
The permissible values for Wmax (Friction work) depend on
the stopping frequency. See diagram at right.
In applications where the brake is operated frequently,
two brake work values should be evaluated to ensure
adequate brake life: the braking work compared to the
braking frequency and the maximum work limit for a
single operation, such as an E-stop. Reviewing these two
values will help determine the optimal solution and ensure
long brake life.

Braking Work (J)

BRAKES

W=

Braking Frequency (Brakes/hr)

168

G1142 Subject to Change Without Notice

www.nord.com

Connections
Typical Connection Diagrams
10

20

15

25

BRAKES

10

10

15

___ = Braking Method

www.nord.com

G1142 Subject to Change Without Notice

169

Connections
Typical Connection Diagrams
20

10

10

15

20

25

20

15

25

BRAKES

10

___ = Braking Method

170

G1142 Subject to Change Without Notice

www.nord.com

Connections
AC Vector Drive Driven Brakemotors
Connection Guide for Brakes with AC-Switching

BRAKES

Connection Guide for Brakes with DC-Switching

www.nord.com

G1142 Subject to Change Without Notice

171

Connections
GPE & GPU Rectier - Connection Diagrams
Motor Across the-Line Operation
Brake Powered from the motor terminal block
GP101

30

START - FAST RELEASE (OVEREXCITATION)


STOP - NORMAL STOP (AC-SWITCHING)
BSG TYPE - EXTERNAL DC-SWITCHING
TERMINAL 3 & 4 - JUMPERED
V = BRAKE VOLTAGE = 230V
B

GP102

35

START - FAST RELEASE (OVEREXCITATION)


STOP - FAST STOP (DC-SWITCHING)
BSG TYPE - EXTERNAL DC-SWITCHING
TERMINAL 3 & 4 - CONTACT OR IR RELAY
V = BRAKE VOLTAGE = 230V
B

GPE20L RECTIFIER
19140230
BLACK

T5

T6

T7

T8

T9

T1

T2

T3

L2

BSG TYPE - EXTERNAL DC-SWITCHING


TERMINAL 3 & 4 - CONTACT OR IR RELAY
V = BRAKE VOLTAGE = 230V
B
GPE20L RECTIFIER
19140230
BLACK

1 2 3 4 5 6

105VDC
BRAKE

VB

HIGH
VOLTAGE

T4

T5

T6

T7

T8

T9

T1

T2

T3

205VDC
BRAKE

VB

HIGH
VOLTAGE

T4

T5

T6

T7

T8

T9

T1

T2

T3

MOTOR
STARTER

MOTOR
STARTER
L1

START - STANDARD RELEASE


STOP - VERY FAST STOP
(REDUCED POWER HOLD DC-SWITCHING)

1 2 3 4 5 6

105VDC
BRAKE
T4

40

GPE20L RECTIFIER
19140230
BLACK

1 2 3 4 5 6

VB

GP103

L3

L1

460VAC

L2

HIGH
VOLTAGE

MOTOR
STARTER

L3

L1

L2

L3

460VAC

460VAC

___ = Braking Method

Power supplied from a seperate power source.


Use with AC vector drives, soft starters, and multi-speed motors
BRAKES

GP104

45

START - FAST RELEASE (OVEREXCITATION)


STOP - NORMAL STOP (AC-SWITCHING)
BSG TYPE - INTEGRATED DC-SWITCHING
TERMINAL 3 & 4 - JUMPERED

GP105

50

START - FAST RELEASE (OVEREXCITATION)


STOP - FAST STOP (DC-SWITCHING)
BSG TYPE - INTEGRATED DC-SWITCHING
TERMINAL 3 & 4 - NOT JUMPERED (OPEN)

GPU40L RECTIFIER
19140170
BLACK

T8

T9

T1

T2

T3

T4

HIGH
VOLTAGE

T5

VB

L1

L2

1 2 3 4 5 6

L3

460VAC
VB = BRAKE VOLTAGE

205VDC
BRAKE

T6

T7

T8

T9

T1

T2

T3

MOTOR
STARTER
460VAC

GPU20L RECTIFIER
19140090
BLACK

205VDC
BRAKE

T6

T7

BSG TYPE - INTEGRATED DC-SWITCHING


TERMINAL 3 & 4 - NOT JUMPERED (OPEN)

1 2 3 4 5 6

205VDC
BRAKE
T5

55

START - STANDARD RELEASE


STOP - VERY FAST STOP
(REDUCED POWER HOLD DC-SWITCHING)

GPU40L RECTIFIER
19140170
BLACK

1 2 3 4 5 6

T4

GP106

HIGH
VOLTAGE

T4

T5

T6

T7

T8

T9

T1

T2

T3

MOTOR
STARTER

MOTOR
STARTER
VB

460VAC

L1

L2

L3

460VAC
VB = BRAKE VOLTAGE

HIGH
VOLTAGE

VB

230VAC

L1

L2

L3

460VAC
VB = BRAKE VOLTAGE

___ = Braking Method

172

G1142 Subject to Change Without Notice

www.nord.com

Connections
IR Relay Typical Connection Diagrams

15

15

15

15

15

15

15

___ = Braking Method

www.nord.com

G1142 Subject to Change Without Notice

173

BRAKES

15

15

Connections
GPE Rectier for External DC-Switching with IR Relay
Method Operation
Start - Fast release (Overexcitation)
Stop - Fast stop (DC-Switching)
GPE type - External DC-Switching
Terminal 3 & 4 - Contact or IR-relay
35

___ = Braking Method

Method Operation
Start - Standard Release
Stop - Very Fast stop (Reduced power Hold)
GPE type - External DC-Switching
Terminal 3 & 4 - Contact or IR-relay
BRAKES

40

___ = Braking Method

174

G1142 Subject to Change Without Notice

www.nord.com

NORD Contacts
Contact
Information:
North America
Global

DRIVESYSTEMS

www.nord.com

G1142 Subject to Change Without Notice

175

International
Contacts - North America
Canada

United States
NORD Gear Corporation - Midwest
Headquarters
800 Nord Drive, P.O. 367
Waunakee, WI 53597

NORD Gear Limited


41 West Drive
Brampton, Ontario L6T 4A1
toll free: 1-800-668-4378
Phone: 1-905-796-3606
fax: 1-905-796-8130
eMail: [email protected]

toll free: 1-888-314-6673


phone: 1-608-849-7300
fax: 1-800-373-6673
eMail: [email protected]

Engrenages NORD Limite

NORD Gear Corporation - East


100 Forsyth Hall Drive
Building 100B
Charlotte, NC 28273

1405 Trans-Canada Hwy.


Suite 245
Dorval, Quebec H9P 2V9
toll free: 1-800-668-4378
phone: 1-514-421-1044
fax: 1-514-421-3973
eMail: [email protected]

toll free: 1-888-314-6673


phone: 1-608-849-0140
fax: 1-888-259-6673
eMail: [email protected]

For Sales ofce or distributors please contact us


or see our website at www.nord.com

NORD Gear Corporation - West


1137 W. Bradford Circle
Corona, CA 92882

Mexico
Mexico NORD Drivesystems SA DE CV
Mexico Regional Ofce
Av. Ruiz Cortines 831 Ote.
Guadalupe, N.L.
Mxico, C.P. 67110

toll free: 1-888-314-6673


phone: 1-608-849-0190
fax: 1-888-408-6673
eMail: [email protected]
For Sales ofce or distributors please contact us
or see our website at www.nord.com

phone: +52-81-8327-4733
fax: +52-81-8327-4735
eMail: [email protected]
For Sales ofce or distributors please contact us
or see our website at www.nord.com

CONTACTS

176

G1142 Subject to Change Without Notice

www.nord.com

International
Contacts
Global

Austria

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-401 0
Fax: +49-4532-401 254
Email: [email protected]

Afghanistan

Getriebebau NORD GmbH


Deggendorfstrae 8
A-4030 Linz
Phone: +43-732-31 89 20
Email: [email protected]

Fax: +43-732-31 89 20-85

Bahrain

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Algeria

Eight Industries
P.O. Box 32095
Dubai/U.A.E.
Phone: +971-4-3200 770
Fax: +971-4-3200 771
Email: [email protected]

Bangladesh

Tunesia S.I.A. Ben Djemaa & CIE


220 Avenue des Martyrs
TN - 3000 Sfax
Phone: +216-74-408 446
Fax: +216-74-408 065
Email: [email protected]

Algeria

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Belarus

EURL Agence Maghrebine Des Echanges Commerciaux


35 Avenue 5 Juillet
Borj El Kiffane
Phone: +213-76-288837
Fax: +213-21-201209
Email: [email protected]

Angola

OOO NORD PRIVODY


P.O. 51
BY-220121 Minsk
Phone: +375-17-205 04 27
Email: [email protected]

Fax: +375-17-205 04 27

Belgium

Power Drives a division of Bearing Man Ltd.


Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431
Jeppestown 2043, South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

NORD Aandrijvingen Belgi N.V.


NORD Transmission Belgique S.A.
Boutersemdreef 24
B-2240 Zandhoven
Phone: +32-3-484 59 21
Fax: +32-3-484 59 24
Email: [email protected]

Bhutan
Argentina
Chilicote S.A.
Avda. Julio A. Roca 546
1067 Buenos Aires
Phone: +54-11-4343 8469
Fax: +54-11-4331 4278
Email: [email protected]

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Bolivia
Armenia
Getriebebau NORD GmbH & Co. KG
Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Brazil

CMG Pty Ltd.


19 Corporate Avenue
Rowville, VIC 3178
PO Box 2340, Rowville, VIC 3178 - Australia
Phone: +61-3-9237 4000
Fax: +61-3-9237 4010
Email: [email protected]

www.nord.com

NORD Motoredutores do Brasil Ltda


Rua Dr. Moacyr Antonio de Morais, 700
Parque Santo Agostinho
Guarulhos So Paulo
CEP 07140-285
Phone: +55-11-6402 8855
Fax: +55-11-6402 8830
Email: [email protected]

G1142 Subject to Change Without Notice

177

CONTACTS

Australia

Variadores S.A.
Carrera 50 (Aut. Sur)
No. 2 Sur 271 - A.A. 053811
Medellin, Columbia
Phone: +57-94-2552200
Fax: +57-94-2557450
Email: [email protected]

International
Contacts
Bulgaria

Colombia

MELSICON Ltd.
P.Wolov 47-49
BG-1504 SOFIA
Phone: +359-2-9434150
Fax: +359-2-9434160
Email: [email protected]

Variadores S.A.
Carrera 50 (Aut. Sur)
No. 2 Sur 271 - A.A. 053811
Medellin
Phone: +57-4-2552200
Fax: +57-4-2557450
Email: [email protected]

Burundi
Power Drives a division of Bearing Man Ltd.
Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431 Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Cameroon

Variadores S.A.
Carrera 50 (Aut. Sur)
No. 2 Sur 271 - A.A. 053811
Medellin, Columbia
Phone: +57-94-2552200
Fax: +57-94-2557450
Email: [email protected]

Croatia

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Canada
NORD Gear Limited
41 West Drive
Brampton, Ontario L6T 4A1
Phone: (905) 796-3606
Email: [email protected]

Costa Rica

NORD-Pogoni d.o.o
Obrtnicka 9
HR-48260 Krizevci
Phone: +385-48-711 900
Email: [email protected]

Fax: +385-48-270 494

Cyprus

Fax: (905) 796-8130

Chile

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-401 441
Fax: +49-4532-401 254
Email: [email protected]

Czech Republic

TDC Techno Drive Center S.A.


Los Leones No. 133-2 Piso
Providencia Santiago de Chile
Chile
Phone: +56-2-234 0084
Fax: +56-2-334 9633
Email: [email protected]

NORD-Pohn c technika, s. r. o.
Palackho 359
500 03 Hradec Krlov
Phone: +420 495 580 310
Fax: +420 495 580 312
Email: [email protected]

Dem. Rep. Congo


China
NORD (Beijing)
Power Transmission Co. Ltd.
No. 5, Tangjiacun,
Guangqudonglu, Chaoyangqu
Beijing 100022
Phone: +86-10-67704305
Fax: +86-10-67704330
Email: [email protected]

CONTACTS

178

Denmark
NORD-Gear Danmark A/S
Kliplev Erhvervspark 28 - Kliplev
DK - 6200 Aabenraa
Phone: +45 73 68 78 00
Fax: +45 73 68 78 10
Email: [email protected]

China
NORD (Suzhou)
Power Transmission Co. Ltd.
No.510 Changyang Street
Suzhou Ind. Park
Jiangsu 215021
Phone: +86-512-85180277
Email: [email protected]

Power Drives a division of Bearing Man Ltd.


Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431 Jeppestown 2043, South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Ecuador
Fax: +86-512-85180278

Variadores S.A.
Carrera 50 (Aut. Sur)
No. 2 Sur 271 - A.A. 053811
Medellin, Columbia
Phone: +57-94-2552200
Fax: +57-94-2557450
Email: [email protected]

G1142 Subject to Change Without Notice

www.nord.com

International
Contacts
Egypt

Greece

IED-International Engineering Development


4 Abu Gafar El Nahas Street
El Golf, Heliopolis
Cairo
Phone: +20-2-2900475
Fax: +20-2-4185637
Email: [email protected]

El Salvador

Guatemala

Maquinaria E Insumos Industriales, S.A.


67 Av Sur Edicio #144 Local #3,.
Col Escalon
San Salvador, C.A
Phone: +503-22243059
Fax: +503-22246272
Email: [email protected]

Estonia
Technobalt Eesti Ltd.
Like tee 10
Peetri kla, Rae vald
EE-75301 Harjumaa
Phone: +372-6-684 400
Email: [email protected]

Mangrinox S.A.
14 Grevenon Str.
Votanikos
GR-11855 Athens
Phone: +30-210-3423201-3
Fax: +30-210-3459767, 3459928
Email: [email protected]

Maquinaria E Insumos Industriales, S.A.


19 Avenida 16-56 Zona 10
Empresarial Santa Fe Bodega 4
Guatemala 01010
Phone: +502-23674490
Fax: +502-23674493
Email: [email protected]

Guinea

Fax: +372-6-613 165

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Hungary
Finland
NORD Gear Oy
Aunankorvenkatu 7
FI - 33840 Tampere
Phone: +358-3-254 1800
Email: [email protected]

Fax: +358-3-254 1820

NORD Hajtastechnika Kft.


Trkk u. 5-7
HU-1037 Budapest
Phone: +36 1 437 0127
Email: [email protected]

Fax: +36 1 250 5549

Iceland
France
NORD Rducteurs
Bureaux commerciaux
17, Av. Georges Clmenceau
FR-93421 Villepinte Cedex
Phone: +33-1-4963 0189
Email: [email protected]

Varmaverk Ltd.
Dalshrauni 5
IS-220 Hafnarroei
Phone: +354-5651750
Email: [email protected]

Fax: +354-5651951

Fax: +33-1-4963 0811

India

Germany
Getriebebau NORD GmbH & Co. KG
Postfach 12 62
Rudolf-Diesel-Strasse 1
D-22941 Bargteheide
Phone: +49-4532-401-0
Fax: +49-4532-401-253
Email: [email protected]

NORD Drivesystems Pvt. Ltd.


282/ 2, 283/2, Plot No. 15
Mauje, Village Mann
Tal Mulshi, Adj. Hinjewadi Phase- II
Pune Maharashtra 411 057
Phone: +91-20-39801200
Fax: +91-20-39801216
Email: [email protected]

Indonesia
Ghana

PT. NORD Indonesia


Jln. Raya Serpong KM7,
Kompleks Rumah Multi Guna Blok D-No. 1
Pakulonan, Serpong 15310 - Tangerang
West Java
Phone: +62-21-5312 2222
Fax: +62-21-5312 2288
Email: [email protected]

CONTACTS

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

www.nord.com

G1142 Subject to Change Without Notice

179

International
Contacts
Iran

Kenya

Paralog Engineering Co. Ltd.


P.O.Box 19395-7366
No. 6, Shangarf Street
Mirdamad Blvd.
Tehran 15489
Phone: +98-21-22905551 / -2 Fax: +98-21-22905550
Email: [email protected]

Jos. Hansen & Soehne (East Africa) Ltd.


Baba Dogo Road, Ruaraka
P.O.Box 30196
Nairobi
Phone: +254-2-861 637
Fax: +254-2-861 640
Email: [email protected]

Kongo
Ireland
NORD Gear Limited (UK)
11 Barton Lane, Abingdon Science Park,
Abingdon,
Oxfordshire OX14 3NB
Phone: +353(0) 87 69 -48 7 11 Fax: +353 (0) 49 85 - 43 7 34
Email: [email protected]

Israel

Power Drives a division of Bearing Man Ltd.


Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431 Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Korea

Ringel Bros. Ltd


Hertzel St. 134
5148 Tel-Aviv
Phone: +972-3-6824027
Fax: +972-3-6822041
Email: [email protected]

Italy

POWERKING GEAR Co.


216-8, No-onsa,
Gwangmyung, Gyunggi, 423-080
Phone: +82-2-2615-6044
Fax: +82-2-2060-7044
Email: [email protected]

Kuwait

NORD-Motoriduttori s.r.l.
Via Newton 22
IT-40017 San Giovanni in Persiceto (BO)
Phone: +39-051-6870 711
Fax: +39-051-6870 793
Email: [email protected]

Ivory Coast

Eight Industries
P.O. Box 32095
Dubai/U.A.E.
Phone: +971-4-3200 770
Fax: +971-4-3200 771
Email: [email protected]

Kyrgyzstand

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Jordan

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Latvia

Arab Co. For Power Transmissions Technology


GearTech Co
P.O Box 830641
Amman 11183
Phone: +962-6-5692283
Fax: +962-6-5656750
Email: [email protected]

SIA Technobalt
Skaistkalnes 1
Riga LV - 1004
Phone: +371-7605 046
Fax: +371-7605 062
Email: [email protected]

Lebanon
Kazakhstan
NORD Privody KZ
Chaykovski str.,
h.131, of.12. KZ - Almaty, 050 000
Phone: +7-3272-61 02 99
Fax: +7-3272-61 02 99
Email: [email protected]

Hosny Homany
P.O. Box 102
Ghobery, Beirut
Phone: +961 5 480661/2
Fax: +961 5 480660
Email: [email protected]

Liberia

CONTACTS

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

180

G1142 Subject to Change Without Notice

www.nord.com

International
Contacts
Lithuania

Netherlands

Technobalt Group
UAB Technobalta
Titnago g.10
LT-02300 Vilnius
Phone: +370-5-260 2503
Fax: +370-5-2653288
Email: [email protected]

NORD Aandrijvingen Nederland B.V.


Voltstraat 12
NL-2181 HA Hillegom
P.O.Box 136
NL-2180 AC Hillegom
Phone: +31-252 529544
Fax: +31-252 522222
Email: [email protected]

Malaysia
GTM Sdn Bhd
No. 19, Jalan Tambur 33/19,
Shah Alam Technology Park, Section 33,
40400, Shah Alam,
Selangor Darul Ehsan
Phone: +60-3-51 24 67 73
Fax: +60-3-51 24 68 10
Email: [email protected]

New Zealand
CMG Electric Motors (NZ) Limited
2 Ross Reid Avenue
East Tamaki, Auckland
Phone: +64-9-273 9162
Fax: +64-9-273 9062
Email: [email protected]

Nigeria
Marocco
Societe Marocaine des Etablissements Moulin
14 Rue Allal Ben Ahmed AMKIK et 7,
Rue Saint Saens
Belvdre - Casablanca
Phone: +212-22-406777
Fax: +212-22-406782
Email: [email protected]

Jos. Hansen & Soehne (Nigeria) Ltd.


km 16, Ikorodu Road (near Bata)
Ojota
Lagos
Phone: +234-1-4974 304
Fax: +234-1-4976 936
Email: [email protected]

Norway
Mauritius
Power Drives a division of Bearing Man Ltd.
Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431
Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Mexico
NORD DRIVESYSTEMS SA DE CV
Av. Lzaro Crdenas 1007 Pte.
San Pedro Garza Garcia, N.L.
Mxico, C.P. 66266
Phone: +52-81-8220-9165
Fax: +52-81-8220-9044
Email: [email protected]

Namibia
Power Drives a division of Bearing Man Ltd.
Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431
Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Nepal

NORD GEAR NORGE A/S


Solgaard Skog 7,
PB85
N-1501 Moss
Phone: +47-69 20 69 90
Fax: +47-69 20 69 93
Email: [email protected]

Oman
Eight Industries
P.O. Box 32095
Dubai/U.A.E.
Phone: +971-4-3200 770
Fax: +971-4-3200 771
Email: [email protected]

Pakistan
OTC
Flat # 3, 89B/C-II,
Gulberg-III
Lahore 54660
Phone: +92-42-587 2667-9
Email: [email protected]

Fax: +92-42-587 2670

Panama
Variadores S.A.
Carrera 50 (Aut. Sur)
No. 2 Sur 271 - A.A. 053811
Medellin, Columbia
Phone: +57-94-2552200
Fax: +57-94-2557450
Email: [email protected]

www.nord.com

G1142 Subject to Change Without Notice

CONTACTS

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

181

International
Contacts
Peru

Rwanda

Delcrosa S.A.
Av. Argentina 1515
Lima
Phone: +51-1-336 6614
Fax: +51-1-336 8189
Email: [email protected]

Philippines
Mheco Mechanical Handling Equipment Company Inc
Suite 812 Herrera Tower,
Herrera cor. Valero Sts.
Salcedo Village, Makati City
P.O.Box 1004
Makati 1250
Phone: +63-2-844 8901-05
Fax: +63-2-845 1535
Email: [email protected]

Power Drives a division of Bearing Man Ltd.


Bearing Man Park, Droste Cresent
Droste Park Ext. 7, Johannesburg 2001
P.O. Box 33431 Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Saudi Arabia
Al-Musairiey Industrial Equipment. Co.
P.O. Box 40966
Riyadh - 11511
Phone: +966-1-448 3808
Fax: +966-1-446 9244
Email: [email protected]

Senegal
Poland
NORD Napedy sp. z o.o.
Ul. Grottgera 30
PL-32-020 Wieliczka
S d Rejonowy dla Krakowa Zrdmiescia
NIP: 683-17-20-355
Kapital ZakBadowy 770 000, 00 PLN
Phone: +48-0122889900
Fax: +48-0122889911
Email: [email protected]

Portugal
NORD Motorreductores
Apdo de Correos 166,
ES-08200 Sabadell - Spain
Phone: +34-93-723 5322
Email: [email protected]

Singapore
NORD GEAR Pte Ltd
33 Kian Teck Drive
Jurong, Singapore 628850
Phone: +65-6265-9118
Email: [email protected]

Fax: +65-6265-6841

Slovakia
Fax: +34-93-723 3147

Qatar
Eight Industries
P.O. Box 32095
Dubai/U.A.E.
Phone: +971-4-3200 770
Fax: +971-4-3200 771
Email: [email protected]

Romania
S.C.NORD Drivesystems S.R.L.
Str.Nicolae Iorga,Nr.55/3
RO-550387 SIBIU
Phone: +40/269/232880
Fax: +40/269/232880
Email: [email protected]

Russian Federation
OOO NORD PRIVODY
Ul. A. Nevsky 9
RU-191167 St.Petersburg
Phone: +7-812-327 0192
Email: [email protected]

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

NORD Pohony, s.r.o.


Juzn Trieda 74
SK - 04001 Kosice
Phone: +421-55-729 9600
Email: [email protected]

Fax: +421-55-729 9599

Slovenia
Getriebebau NORD GmbH
Deggendorfstrae 8
A-4030 Linz
Phone: +43-732-31 89 20
Email: [email protected]

Fax: +43-732-31 89 20-85

South Africa
Power Drives a division of Bearing Man Ltd.
6 Tetford Circle,
Millennium Bridge Business Park,
La Lucia Ridge 4320 (Durban)
P.O. Box 25191, Gateway 4321 (Durban)
Phone: +27-11-62 01 61 3
Fax: +27-11-62 01 67 0
Email: [email protected]

Fax: +7-812-327 0192

CONTACTS

182

G1142 Subject to Change Without Notice

www.nord.com

International
Contacts
Spain
NORD Motorreductores S.A.
Aptdo de Correos 166
ES - 08200 Sabadell
Phone: +34-93-723 5322
Email: [email protected]

Thailand

Fax: +34-93-723 3147

Charoen Muang Machinery Co. Ltd.


164/1 Wisutkasat Rd.
Banpanthom, Pranakorn
Bangkok 10200
Phone: +66-2-281 5331
Fax: +66-2-280 8033-4
Email: [email protected]

Sri Lanka
Getriebebau NORD GmbH & Co. KG
Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Tunisia
Tunesia S.I.A. Ben Djemaa & CIE
220 Avenue des Martyrs
TN - 3000 Sfax
Phone: +216-74-408 446
Fax: +216-74-408 065
Email: [email protected]

Sweden
NORD Drivsystem AB
Box 2097
Ryttargatan 277
SE-194 02 Upplands Vsby
Phone: +46-8-594 114 00
Email: [email protected]

Turkey

Fax: +46-8-594 114 14

Switzerland
Getriebebau NORD AG
Bchigenstr.18
CH-9212 Arnegg
Phone: +41-71-38899 11
Email: [email protected]

NORD-REMAS
Redktr Sanayi ve
Ticaret Ltd. Sti.
Teperen Ky
34959 - Tuzla - Istanbul
Phone: +90-216-304 13 60
Email: [email protected]

Fax: +90-216-304 13 69

Uganda
Fax: +41-71-38899 15

Syria
Elias Brothers Co.
Al Kowatly St. 2
P.O. Box 4282
Homs
Phone: +963-31-2771 004
Fax: +963-31-2771 003
Email: [email protected]

Taiwan
TACT Trans-Asia Consulting & Trade Co., Ltd.
1F, No. 157-1, Sec. 1, Beisin Road.,
Sindian City,
Taipei County 231, Taiwan R.O.C.
Phone: + 886-2-29188768
Fax: + 886-2-29185985
Email: [email protected]

Tanzania

Ukraine
GETRIEBEBAU NORD GmbH
Vasilkovskaja, 1
ofce 306
03040 KIEW
Phone: + 380-44-537 0615
Email: [email protected]

Fax: + 380-44-537 0615

United Arab Emirates


Eight Industries
P.O. Box 32095
Dubai/U.A.E.
Phone: +971-4-3200 770
Fax: +971-4-3200 771
Email: [email protected]

United Kingdom
NORD Gear Limited (UK)
11 Barton Lane, Abingdon Science Park,
Abingdon,
Oxfordshire OX14 3NB
Phone: +44-1235-534404
Fax: +44-1235-534414
Email: [email protected]
CONTACTS

Jos. Hansen & Soehne (Tanzania) Ltd.


Holland House, Ohio Street
P.O.Box 9521
Dar es Salaam
Phone: +255-22-211 5746
Fax: +255-22-211 2948
Email: [email protected]

Jos. Hansen & Soehne (Uganda) Ltd.


Workers House Plot 1
Pilkington Road
P.O.Box 2333
Kampala
Phone: +256-41-251 324
Fax: +256-41-251 325
Email: [email protected]

www.nord.com

G1142 Subject to Change Without Notice

183

International
Contacts
United States - Midwest
NORD Gear Corporation
800 Nord Drive, P.O. 367
Waunakee, WI 53597
Phone: 1-888-314-6673
Phone: 1-608-849-7300
Email: [email protected]

Vietnam

Fax: 1-800-373-6673

United States - West


NORD Gear Corporation
1137 W. Bradford Circle
Corona, CA 92882
Toll free: 1-888-314-6673
Phone: 1-608-849-0190
Email: [email protected]

Zambia
Fax: 1-888-408-6673

United States - East


NORD Gear Corporation
100 Forsyth Hall Drive
Building 100B
Charlotte, NC 28273
Toll free: 1-888-314-6673
Phone: 1-608-849-0140
Email: [email protected]

NORD Gear Pte. Ltd


Representative ofce
Unit 401, 4F, An Dinh Building,
18 Nam Quoc Cang Street
Pham Ngu Lao Ward
District 1, Ho Chi Minh City, Vietnam
Phone: +84 8 925 7270
Fax: +84 8 925 7271
Email: [email protected]

PROVIDENT INVESTMENT Ltd


Mr.Y.M.Mulambya
1st. Floor - Angoni House
Obote Avenenue
Kitwe
Phone: +260-2-22 60 84
Fax: +260-2-22 67 10
Email: [email protected]

Zimbabwe
Fax: 1-888-259-6673

Uzbekistan

Power Drives a division of Bearing Man Ltd.


Bearing Man Park, Droste Cresent
P.O. Box 33431 Jeppestown 2043
South Africa
Phone: +27-11-620 1500
Fax: +27-11-620 1670
Email: [email protected]

Getriebebau NORD GmbH & Co. KG


Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

Venezuela
Getriebebau NORD GmbH & Co. KG
Rudolf-Diesel Str.1
22941 Bargteheide / Hamburg Germany
Phone: +49-4532-4010
Fax: +49-4532-401254
Email: [email protected]

CONTACTS

184

G1142 Subject to Change Without Notice

www.nord.com

92 Series Bevel
Ordering Guide
SK

Shaft/Mounting

Reducer Options

Gear Unit

:1
see pages 58 - 71
OR
Output Speed

rpm

H - Hollow Shaft Cover 18


D - Torque Arm 19
LL - Long Term Storage 21
NEMA
Adapter
N56C
N140TC
N180TC
N210TC
N250TC

see page 15

Integral Motors
63S/4 - 0.16hp
63L/4 - 0.25hp
71S/4 - 0.33hp
71L/4 - 0.50hp
80S/4 - 0.75hp
80L/4 - 1hp
90S/4 - 1.5hp
90L/4 - 2hp
100L/4 - 3hp
100LA/4 - 5hp
112M/4 - 5.4hp
132S/4 - 7.5hp
132M/4 - 10hp
Other Speeds Available

Paint

M5

M4

M3

B5 Flange Side
(if required)

B5 Flange Diameter
(if required)

Location
see page 15

see page 15

Side A

Side B

H66 Side
(if required)

H66 Side A

H66 Side B

see page 15

see page 15

TB2

CE III*

Conduit Entry Loc.

TB1

Terminal Box Pos.

TB1

TB2

TB3

TB4

TB3

www.nord.com

Lubricant

Standard
Synthetic
Food Grade
Other _______

Torque Arm Side


Shrink Disc Side
& Location (if required)
(if required)

Side A

Side B

Gearmotor Only Details


Voltage & Frequency

230/460V-60Hz (460V only 40 hp)

575V-60Hz

208V-60Hz

400V-50Hz

115/230V-60Hz, 1 ph.

Other ___________

Other Speeds Available

Standard Stainless Steel Paint


NSD+ (gray)
NSD+W (white)
NSD-X3 (gray)
NSD-X3W (white)
Casting Primed
Special _______

M2

Flange Side A

Flange Side B

Flange Side A&B


see pages 113 - 114

Integral Energy
Efcent Motors
80LH/4 - 1hp
90SH/4 - 1.5hp
90LH/4 - 2hp
100LH/4 - 3hp
112MH/4 - 5hp
132SH/4 - 7.5hp
132MH/4 - 10hp

M1

M6

see pages 58 - 71

Shaft Side A

Shaft Side B

Shaft Side A&B

Vl - Flouro-rubber Seals 20
SM5 - Stainless Steel Shaft 19 OSG - Oil Sight Glass 20
SWA - Special Hollow Shaft 19
MDP - Magnetic Drain Plug 21
SS - Special Shrink Disc 19
ADP - Additional Drain Plug 21
PR - Flange Pilot Removal 17

IEC
Adapter
IEC 63
IEC 71
IEC 80
IEC 90
IEC 100
IEC 112
IEC 132
IEC160

Mounting Position
M1
M2
M3
M4
M5
M6
Special _______

Hollow Shaft
Solid Shaft Side
Diameter (if required)
(if required)

B - Fixing Element Kit 19

Product Specications
Ratio

see page 126

Reducer Options

Input
Shaft
W

see page 23

AFSH - Hollow Shaft/B5 Flange/Shrink Disc


AZSH - Hollow Shaft/B14 Flange/Shrink Disc

Motor Options

Shaft/Mounting
AX - Hollow Shaft/Foot Mount
AF - Hollow Shaft/B5 Flange
AZ - Hollow Shaft/B14 Flange

- Solid Shaft/Foot Mount


VF - Solid Shaft/B5 Flange
VZ - Solid Shaft/B14 Flange
VFL - Double Solid Shaft /B5 Flange
LX - Double Solid Shaft/Foot
LXZ - Double Solid Shaft/Foot/ B14 Flange

92072
92172
92372
92672
92772

Motor/Input

TB4

Mtg. Pos. M1 Shown


G1142 Subject to Change Without Notice

CE I

CE II

CE III

CE IV

Brakemotor

CE II

CE IV
CONTACTS

Gear Unit

CE I*

Mtg. Pos. M1 Shown

185

Motor
Order Form
Frame

Size

Poles

63
71
80
90
100
112
132

S
SH
M
MH
MX
L
LA
LH
LX

4
2
6
4-2
8-2
8-4
12-2
Other

Motor Options

Brake Size

Brake Options

SK
Electrical Motor Options
H - Energy Efcient Motor
TW - Thermostat
TF - Thermistor
SH - Space Heater (select voltage)

110 Volt
230 Volt 460 Volt
ISO H - Class H insulation
WU - High Resistance Rotor
4-2 - 2-Speed, 4/2 Pole, 1800/3600rpm
8-2 - 2-Speed, 8/2 Pole, 900/3600rpm
ECR - Single Phase Motor

BRE 5
BRE 10
BRE 20
BRE 40
BRE 60
BRE 100
BRE 150

Environmental Options

NSD+ - Nord Severe Duty Paint


NSDx3 - Nord Extreme Duty Paint
RD - Canopy Drip Cover
RDD - Double Fan Cover
KB - Condensation Drain Holes (plugged)
KBO - Condensation Drain Holes (open)
IP66 - IP66 Enclosure Protection
KKV - Terminal Box Sealed with Resin
AICM - Additional Insulation
EP - Epoxy Dipped Windings

Unpainted Aluminum Alloy

Stainless Steel Paint

NSD+ (gray)

NSD+W (white)

NSD-X3 (gray)

NSD-X3W (white)

Special _______

Rectier Selection
Rectier Wiring

Across the line (from motor terminal box)

Separate power source (frequency inverter, soft starter)

Frequency Inverter Related Options


F - Blower Fan (200-575V 1 & 3 Phase)
FC - Blower Cooling Fan (115V, 1 Phase)
IG__ - Incremental Encoder
IG__P - Incremental Encoder with Plug
AG - Absolute Encoder
Additional Motor Options
OL - Totally Enclosed Non-Ventilated (TENV)
OL/H - (TENV) Without Fan Cover
WE - Second Shaft Extension (Fan Side)
HR - Hand Wheel
Z - High Inertia Cast Iron Fan
RLS - Motor Backstop (rotation viewing fan)

Clockwise
Counter-Clockwise
EKK - Small Terminal Box (not UL approved)
MS - Quick Power Plug Connector

Brake Supply Voltage

Braking Method

24 VDC

115 VAC

200 VAC

230 VAC

400 VAC

460 VAC

500 VAC

575 VAC

Other ____________

Method 10

Method 15

Method 20

Method 25

Method 30

Method 35

Method 40

Method 45

Method 50

Method 55

Hand Release Position


HL 2

HL 3

HL1

HL2

HL3

HL4

HL 1

Paint

HL - Hand Release Lever


FHL - Locking Hand Release Lever
HLH - Hand Release Lever with Hole
RG - Corrosion Protected Brake
SR - Dust and Corrosion Protected Brake
ADJ_____Nm - Adjust Brake Torque
BIP66 - IP66 Brake Enclosure
MIK - Micro-switch
BSH - Brake Heating/Bilar Coil
NRB1 - Quiet Brake Release
NRB2 - Quiet Brake Motor Operation
FBR - Brass Foil
DBR - Double Brake
G...P - High Performance Rectier
G...V - Sealed Rectier
IR - Current Sensing Relay

HL 4

Terminal Box Pos.

Integral to gearbox

NEMA C-Face

IEC B5 Mount

230/460V-60Hz

575V-60Hz

208V-60Hz

400V-50Hz

115/230V, 60Hz-1-ph.

Other

TB1

TB2

TB3

TB4

Conduit Entry Loc.

TB3

186

TB2

TB1

Voltage & Frequency

CONTACTS

Mounting

CE I
CE II
CE III
CE IV

G1142 Subject to Change Without Notice

CE II

CE IV

CE I*

TB4

Mtg. Pos. M1 Shown

CE III*

* Brakemotor

Mtg. Pos. M1 Shown

www.nord.com

NORD GEAR CORPORATION


Conditions of Sale
1. CONTRACT
Any contract between Nord Gear Corporation, hereinafter designated as Seller, and the Buyer is subject to the terms and conditions
of sale hereinafter set forth. Any deviation from such terms and conditions must be specifically set forth in writing and consented
to by Seller. Accordingly, the Buyer and Seller acknowledge and agree that the terms and conditions set forth below and on the
face hereof shall govern Buyers purchase of the goods described on the face hereof and shall take precedence over and represents
the final agreement between Buyer and Seller, notwithstanding any inconsistent, contradictory or other prior or further conditions
contained in any oral or written request or purchase order issued by Buyer or any other document furnished by Buyer in connection
with its purchase of the Goods, regardless of whether such document or documents are exchanged simultaneously with this Invoice or
prior or subsequent thereto. Any additional or different terms or conditions which may appear in any communicaiton, oral or written,
from Seller, its officers, employees, agents or representatives, are hereby expressly rejected and shall not be effective or binding upon
the Seller, unless specifically hereafter agreed to in writing by Seller and no such additional or different terms or conditions in any
document submitted to Seller by Buyer shall become part of the contract between Buyer and Seller, unless such written acceptance
by Seller specifically recognizes and assents to their inclusion. Any objection by Buyer to the terms and conditions hereof shall be
ineffective unless Seller is advised in writing thereof within two (2) days of the date of this Invoice.
2. CONFIRMATION
An order shall be deemed accepted only when duly confirmed by Seller, at Nord Gear Corporations home office in Waunakee,
Wisconsin, and upon such confirmation the order shall become a contract binding upon the parties hereto, their successors and
assigns.
3. PRICES
Prices shown are list prices and may be subject to applicable discounts. Unless otherwise agreed upon in writing, prices are FOB
factory Waunakee, Wisconsin. Prices and discounts are subject to change without notice until order is accepted. Sellers prices do
not include cost of any inspection permits required.
4. LIMITED WARRANTY
Seller warrants the goods sold hereunder to be free from defects in material and workmanship under normal use and service not
arising from misuse, negligence, or accident, including but not limited to the use, installation, and transportation of the goods by
the Buyer, its agents, servants, employees, or by carriers. Such obligations under this warranty are limited to remedying any
deficiencies in the goods at Waunakee, Wisconsin, or at such place or places in the United States of America as may be designated
by Seller. THIS WARRANTY SHALL PERTAIN TO ANY PART OR PARTS OF ANY GOODS TO WHICH BUYER OR ITS ASSIGNS HAS
GIVEN WRITTEN NOTICE OF CLAIMED DEFECTS TO SELLER. NORD GEAR CORP. WARRANTS ITS PRODUCTS AGAINST DEFECTS IN
MATERIAL AND WORKMANSHIP FOR A PERIOD OF 12 MONTHS FROM DATE OF INSTALLATION OR 18 MONTHS FROM DATE OF
SHIPMENT WHICHEVER COMES FIRST ON ALL COMPONENTS. 36 MONTHS FROM DATE OF INVOICE OR 24 MONTHS FROM DATE
OF INSTALLATION WHICHEVER COMES FIRST ON GEARS AND HOUSINGS ONLY. PARTS WHICH ARE SUBJECT TO OPERATIONAL WEAR
AND TEAR, SUCH AS BELTS & TRACTION DISCS, ARE NOT COVERED BY THE LIMITED WARRANTY. Buyer shall be required to furnish
Seller with details of such defects and this warranty shall be effective as to such goods which Sellers examination shall disclose to
its satisfaction to have been defective and which at Sellers option shall promptly thereafter be returned to Seller or its nominees.
THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. EXCEPT FOR THE
EXPRESS WARRANTIES SET FORTH HEREIN, SELLER HAS MADE AND MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, AS
TO THE GOODS SOLD HEREUNDER, INCLUDING, BUT NOT LIMITED TO, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE. ANY DESCRIPTION OR MODEL OF THE GOODS IS FOR IDENTIFICATION OR ILLUSTRATIVE PURPOSES ONLY AND SHALL
NOT BE DEEMED TO CREATE ANY WARRANTY, EXPRESS OR IMPLIED. SELLER MAKES NO REPRESENTATIONS AS TO THE CAPACITY
OR PERFORMANCE OF THE GOODS SOLD HEREUNDER, EXCEPT AS SET FORTH IN THE INVOICES SPECIFICATIONS OR OTHER VALID
AGREEMENT OR CONDITION AGREED TO BETWEEN THE PARTIES, AND ANY SUCH REPRESENTATIONS ARE EXPRESSLY CONDITIONED
UPON THE CORRECTNESS OF THE DATA AND INFORMATION FURNISHED BY THE BUYER AND UPON THE GOODS BEING PROPERLY
INSTALLED AND MAINTAINED. THE REMEDIES OF THE BUYER PROVIDED HEREUNDER ARE EXCLUSIVE. In no event shall the Seller be
liable to the Buyer or to any other person for any loss or damage, direct or indirect, arising out of or caused by the use or operation
of the goods, or for the loss of profits, business, or good will, or for any incidental, special or consequential damages. Seller shall
in no event be liable to any person or firm (including any assignee or Buyer) except Buyer and its successors. Unless specifically
authorized by Seller in writing, Seller shall not become responsible for any repair work done by Buyer or any other party on any
goods sold. Any and all costs of the return to the Seller of such goods and all related costs to remove and re-install such goods, shall
be borne by Buyer. Goods sold but not manufactured by the Seller are being warranted as to defects in material and workmanship
consistent with the limited warranty policy of the original manufacturer of the goods and if there is not such a limited warranty policy,
the warranty shall be limited to the provision of the preceding paragraph of Article 4 herein. Standards for the operating characteristics
of the gearboxes and the gearmotors are in conformity with Sellers tests.
5. SHORTAGE AND NONCONFORMITY
Any claim of shortage or that the goods do not conform with the specifications of the order or model must be made in writing within
ten (10) days after delivery of the goods (as to which such claim is made) to Buyer or its nominees, but in no event shall the claim
be later than within the time limit provided by the carrier or insurance company, otherwise such claim shall be deemed waived.
Buyer may not return any goods claimed to be in non-conformity without Sellers prior written authorization. Goods returned without
permission will not be accepted, including for credit, and will be returned to Buyer, F.O.B. Sellters plant. Any claim based on the
receipt of damaged Goods must be filed with the carrier which delivered the goods. The samples, measurements, dimensions and
weights contained in the Sellers catalogs, sales manuals, photographs and drawings constitute only an approximate guide. The
Seller reserves the right to make any change which the Seller, in its absolute discretion, considers necessary. While the goods will be
delivered principally according to specifications or standards or quantities agreed upon, insignificant deviations or insignificant changes
in construction are permissible. The same applies to partial deliveries, In the event that Buyer has a verified claim of shortage or
nonconformity of the goods to the specifications of the order or the model, and if such claim has been submitted within the required
time limit as set forth above, the Seller shall, at its own expense, make up for the shortage of the goods, or replace or repair the
goods, as the case may be, but in no event shall Seller be or become liable to Buyer or to any other person or persons for any loss
in damage, direct or indirect, arising out of or caused by such incidents or for the loss of profits, business or good will. The liability of
the Seller to Buyer, if any hereunder, for breach of warranty, contract, negligence or otherwise, shall in no event exceed the amount
of the purchase price of the goods sold with respect to which any damages are claimed. Shipping dates are estimates unless parties
expressly agree on time of the essence.
6. FORCE MAJEURE
The obligation of the Seller shall be modified or excused, as the case may be, for reasons of Acts of God, war, governmental law
regulations, strikes or lock-outs, fire, breakdown of machinery, whether in its own business enterprise, or if for any other cause beyond
Sellers control, the goods cannot be delivered or their delivery becomes delayed in whole or in part. In the above instances time for
delivery shall be extended for the period of the delay caused, with the proviso, however, that either party may cancel in writing the
undelivered portion of the order or contract if the delay exceeds six (6) months from the delivery date originally confirmed by Seller.
In no event shall Seller become liable in the aforesaid instances to Buyer or any third party for consequential damages or business loss.
7. SHIPMENT AS UNIT
Each shipment by Seller shall be treated as a separate and distinct unit with respect, but only with respect to forwarding, terms of
payment, and the making of claims by the Buyer: provided, however, that if the Buyer defaults in the payment of any obligation
to Seller or any installments thereof, under any agreement between Buyer and Seller, or if Buyer refuses to accept any goods when
tendered for delivery, the Seller may, on fifteen (15) days written notice to the Buyer, without prejudice to Sellers other lawful
remedies, either defer further performance until the defaulted payments are made in full, or make future deliveries for cash in advance
only, or treat the entire contract or contracts with Buyer as breached by the Buyer and pursue its remedies for breach.
8. BUYERS REFUSAL OF DELIVERY
If Buyer refuses to accept delivery of any goods tendered for delivery, then Seller, without prejudice to Sellers other lawful remedies,
may either store or cause such goods to be stored in a warehouse, for buyers account and at Buyers cost, risk and expense, or sell
such goods (without notice) to any purchases at public or private sale, and hold the Buyer liable for any difference between (a) the
contract price of the goods, and (b) the price at which goods are resold less the costs and expense of such resale including brokerage
commissions, or restocking charges.

9. GOODS IN TRANSIT
If prior to delivery or while the goods are in transit, Buyer or Seller becomes bankrupt or insolvent, or any petition in bankruptcy or
for the reorganization or for a state court receivership is filed against Buyer or Seller, as the case may be, then the other party hereto
may forthwith terminate this contract by giving written notice of such termination. Such termination shall not affect any claim for
damages available to the Buyer, provided that if Buyer is then indebted to Seller, the amount of any such damage claim shall be
abated to the extent that the indebtedness of Buyer to Seller, as actually paid in money, is abated by any order of judgement entered
or any plan adopted in any bankruptcy, reorganization, receivership, or similar proceeding. Such termination shall not prejudice the
Sellers rights to any amounts then due under the contract. If Buyer becomes bankrupt or insolvent or any petition in bankruptcy
or for reorganizing or if a state court receivership is filed against Buyer, then, at its option Seller may take possession of any goods
theretofore sold to Buyer, in connection with which the full purchase price has not been paid, analogous to the terns and provisions
set forth in Paragraphs 11 and 12 hereinafter.
10. DELIVERY
(a) Any indicated dates of delivery are approximate only, but NORD Gear will attempt to meet them whenever possible. (b) NORD
Gear will not be liable for any penalty clausess contained in any specifications or order submitted unless agreed to in writing by an
authorized officer of NORD Gear Corporation. (c) Unless otherwise agreed, delivery of the goods to any carrier shall constitute delivery
to the Buyer, and thereafter the risk of loss or damage to the goods shall be upon the Buyer. (d) If the Buyer does not give delivery
instructions to the Seller at least (10) days prior to the delivery date ex factory confirmed by the Seller, the Seller may deliver
the goods to a carrier of its own choosing, at Buyers cost and risk, or, at Sellers option, may store the goods on the pier or any
warehouse, at Buyers cost and risk. Any purchase price in such event becomes due and payable within ten (10) days of such storage.
11. PAYMENT OF PURCHASE PRICE
Time of payment is of the essence under the contract. Unless otherwise provided, terms of payment are 30 days net from the date
of invoice with a 1% discount if paid within 10 days of date of invoice. Upon default in any of the terms of the contract, or failure
to comply with any of the conditions thereof, or upon seizure of the property under execution or other legal process, or if the Buyer
becomes bankrupt or insolvent, or any petition for reorganization or for a state court receivership is filed against Buyer, or if the Buyer
makes any assignment for the benefit of its creditors or otherwise sells, encumbers or disposes of the goods, or if for any other
reason the Seller should deem itself insecure, the full amount of the purchase price then remaining unpaid shall at once become due
and payable at the option of the Seller.
12. BUYERS DEFAULT
Upon the Buyers default, the Seller may dispose of the merchandise in any manner that it deems fit and, if it desires to resell same,
may do so at private or public sale, with or without notice, and with or without the property being at the place of sale, subject,
however, to applicable laws. The Seller or its assigns shall have the right to bid at such sale and may become the purchaser of the
property. The proceeds of the sale shall first be applied to the expenses incurred in retaking, repairing, storing and selling the goods,
reasonable attorneys fees included, and then shall be applied to the payment of the balance due under the contract. Any surplus
amount shall be paid to the Buyer. If a deficiency results after the resale, the Buyer agrees to pay such forthwith, together with
reasonable attorneys fees, for the recovery of the goods incurred by the Seller. If upon the Buyers default, the Seller elects not
to resell any goods which it may repossess, then the cost of repossession, including reasonable attorneys fees, shall forthwith be
due and payable from Buyer to Seller. Buyer agrees to pay all reasonable costs and reasonable attorneys fees incurred by Seller in
enforcing Sellers rights against Buyer, including Sellers right to payment of the purchase price of the goods and Buyers payment of
all other amounts owing to Seller required under this Invoice and Conditions of Sale.
13. SECURITY INTEREST AND TITLE
In states and localities which are governed by the Uniform Commercial Code, this contract shall serve as security agreement, reserving
in Seller a security interest until full payment of purchase price. The provisions of the Uniform Commercial Code regarding security
interest shall have preference and apply if inconsistent with other terms of the conditions of sale. In states and localities where
the Uniform Commercial Code does not apply, title to the goods shall remain in the Seller or its assigns until full payment of the
purchase price. Buyer agrees to execute forthwith any and all documents in such a way and form as Seller may need for filing or
recording the security interest under the Uniform Commercial Code with the proper registers or offices, or for filing or recording the
conditional sales contract.
14. SALES AND USE TAX
Buyer agrees to bear and pay any sales or use tax in connection with the purchase herein, and to hold the Seller harmless from
payment. At the option the Seller, Buyer shall give evidence of payment or of exemption certificate.
15. INSURANCE
The Buyer shall keep the goods insured against damage by fire, water or other casualty as required by Seller, with a company
acceptable to Seller, with loss payable to Seller for the total purchase price until the Seller is fully paid. Seller, if it so elects, may
place said insurance at Buyers expense; Seller may cancel such insurance at any time and without notice and may receive the return
premium, if any.
16. MODIFICATION BY SELLER
Any contract may be assigned or transferred by the Seller, or the time for the making of any payment due by Buyer may be extended
by Seller without derogation of any of the rights of the Seller or its assigns. Waiver by any party of any default shall not be deemed
a waiver of any subsequent default.
17. RETURNED GOODS
No goods will be accepted for return unless authorized in writing by Seller. In all cases, transportation and restocking charges will
be borne by Buyer.
18. PACKING
The Buyer will be charged for export packaging or other special packing desired. Cost for cartage to ship or transfer express will be
added to the invoice. No credit will be allowed if no packing is required.
19. CHANGES/CANCELLATION
NORD Gear will not accept changes in specifications to a confirmed order unless such changes are requested in writing and confirmed
back in writing. In addition, the purchaser must to agree to any additional charges that may arise from the change. Placing orders on
hold or cancellation of orders require Sellers written approval, and are subject to cancellation and/or restocking charges.
20. BUYERS RESPONSIBILITY AS TO MAINTENANCE
Buyer shall use and shall require its employees and agents to use all safety devices and guards and shall maintain the same in proper
working order. Buyer shall use and require its employees and agents to use safe operation procedures in operating the equipment and
shall further obey and have its employees and agents obey safety instructions given by Seller. If Buyer fails to meet the obligations
herein, Buyer agrees to defend, indemnify and save Seller harmless from any liability or obligation with regard to any personal
injuries or property damages directly or indirectly connected with the operation of the equipment. Buyer further agrees to notify Seller
promptly and in any event not later than ten (10) days after notice or knowledge of any accident or malfunction involving Sellers
equipment which has caused personal injury or property damages and to cooperate fully with Seller in investigating and determining
the causes of such accident and malfunction. In the event that Buyer fails to give such notice to Seller or to cooperate with Seller,
Buyer shall be obligated to defend, indemnify and save Seller harmless from any such claims arising from such accident.
21. MISCELLANEOUS PROVISIONS
(a) If for any reason a provision of a contract is legally invalid, then in such event the rest of the contract shall remain in full force and
affect, except that the parties shall try to replace such invalid provision closest to their original mutual intentions. (b) This Invoice and
these Conditions of Sale constitute the entire agreement between the parties regarding the subject matter hereof and supercedes all
prior agreements, understandings and statements, whether oral or written, regarding such subject matter. No modification to, change
in or departure from, the provisions of this Invoice and Conditions of Sale shall be valid or binding on Seller, unless approved in writing
by Seller. No course of dealing or usage of trade shall be applicable unless expressly incorporated into this Invoice and Conditions of
Sale. Any amendments to any contract or contracts between the parties shall be valid only upon the written consent of both parties.
22. NON ASSIGNMENT BY BUYER
Contract or contracts may not be assigned by the Buyer without prior written consent of the Seller.
23. APPLICABLE LAW AND VENUE
All contracts and their interpretation are governed by the applicable, substantive laws of the State of Wisconsin. Any litigation brought
by the Buyer regarding this Invoice or goods purchased hereunder may only be brought in the Circuit Court for Dane County, Wisconsin.

Nord Gear Company Terms 12/4/06

92 Series Bevel
Innovative Design

Product
Overview
UNICASE SPEED REDUCERS
FOOT-MOUNT
GEARMOTOR

FOOT-MOUNT REDUCER
NEMA C-FACE INPUT

HELICAL IN-LINE
- Foot or Flange Mount
- Torque up to 205,000 lb-in
- Gear ratios 1.82:1 to over 300,000:1

MINICASE RIGHT ANGLE WORM


- Foot, Flange or Shaft Mount
- Torque up to 3,540 lb-in
- Gear ratios 5:1 to 500:1

NORDBLOC.1 HELICAL IN-LINE


- Foot or Flange Mount
- Torque up to 26,550 lb-in
- Gear ratios 1.88:1 to over 370:1

FLEXBLOC WORM
- Modular bolt-on options
- Torque up to 4,683 lb-in
- Gear ratios 5:1 to 3,000:1

PARALLEL HELICAL CLINCHER


- Shaft, Flange or Foot Mount
- Torque up to 797,000 lb-in
- Gear ratios 4.26:1 to over 300,000:1

MAXXDRIVE LARGE INDUSTRIAL


GEAR UNITS PARALLEL HELICAL
- Modular bolt-on options
- Torque up to 2,027,000 lb-in
- Gear ratios 5:1 to 1,600:1

SCP SCREW CONVEYOR PACKAGE


- Shaft, or Flange Mount
- Torque up to 53,100 lb-in
- Gear ratios 4.32:1 to over 1500:1

FLANGE-MOUNT REDUCER
GEARMOTOR &
SOLID OUTPUT SHAFT

RIGHT ANGLE
HELICAL-BEVEL 2-STAGE
- Foot, Flange or Shaft Mount
- Torque up to 5,840 lb-in
- Gear ratios 4.1:1 to 72:1
RIGHT ANGLE HELICAL-BEVEL
- Foot, Flange or Shaft Mount
- Torque up to 283,000 lb-in
- Gear ratios 8.04:1 to over 300,000:1
RIGHT ANGLE HELICAL-WORM
- Foot, Flange or Shaft Mount
- Torque up to 27,585 lb-in
- Gear ratios 4.40:1 to over 300,000:1

FOOT-MOUNT
SOLID INPUT SHAFT &
DOUBLE OUTPUT SHAFT

DRIVESYSTEMS

UNICASE SPEED REDUCERS

HIGH PERFORMANCE
MOTORS & BRAKEMOTORS
INVERTER/VECTOR DUTY
- Standard or Energy Efficient
- Integral, NEMA or Metric IEC
- 1/6 to 250 hp

MAXXDRIVE LARGE INDUSTRIAL


GEAR UNITS HELICAL-BEVEL
- Modular bolt-on options
- Torque up to 2,027,000 lb-in
- Gear ratios 5:1 to 1,600:1

NORDAC
AC VECTOR DRIVES
SK200E
- Decentralized, high
- 380-480V, 3-phase
- 200-240V, 3-phase
- 200-240V, 1-phase
- 100-120V, 1-phase

performance
to 10 hp
to 5 hp
to 1.5 hp
to 1 hp

SK500/520/530E
- Compact, high performance
- 380-480V, 3-phase, to 30hp
- 200-240V, 3-phase, to 15hp
- 200-240V, 1-phase, to 3hp
- 110-120V, 1-phase, to 1.5hp
SK700E
- Flexible high performance
- 380-460V, 3-phase, to 200hp

DRIVESYSTEMS

Intelligent Drivesystems

NORD GEAR - 92 SERIES BEVEL GEARMOTORS & SPEED REDUCERS

WEST
Corona, CA (Los Angeles)
Phone: 608.849.0190

MIDWEST
Waunakee, WI (Madison)
Phone: 608.849.7300

EAST
Charlotte, NC
Phone: 608.849.0140

NORD Gear Limited


Toll-Free in Canada: 800.668.4378
[email protected]
CANADA
Brampton, ON (Toronto)
Phone: 905.796.3606

Durable & Premium Efcient Gear Units

G1142

www.nord.com

NORD Gear Corporation


National Customer Service Toll-Free: 888.314.6673
[email protected]

100200106/0310

DRIVESYSTEMS

92 SERIES BEVEL
GEARMOTORS & SPEED REDUCERS
G1142

DRIVESYSTEMS

You might also like