Infinity Catalog
Infinity Catalog
Infinity Catalog
The heart of Infinity is solid brass, nickel-plated fittings that make the system easy to use and install. Infinity's powder-coated
aluminum pipes are so light, that they can be handled and installed by one person. Yet when coupled with solid brass fittings, the
system yields unbeatable performance and reliability.
Unlike plastic piping systems which fail with age and wear, Infinity provides reliability and durability that can only be
achieved through an all-metal system - plus some unique advantages.
Infinity offers the easiest, fastest installation available. There's no welding, gluing or threading, and very little skill is
needed for a professional installation. In fact, a simple pipe cutter and de-burring pipe reamer are the only tools required.
Having a totally metal design provides an integrity that cannot be matched by any other system.
With six different piping sizes, Infinity is a sure fit for virtually any industrial and OEM application, including aerospace,
automotive, chemical processing, electronics, engineering, food and beverage, packaging, pharmaceuticals, and textiles. Our
standard, color-coded design affords three separate systems that can be easily identified by staff members:
Presented By:
TECHNICAL CHARACTERISTICS
Temperatures
Minimum temperature -20C (-4F)
Maximum temperature +80C (176F)
2
Pressures
Minimum pressure -0.99 bar (-29.6Hg)
Maximum pressure 15 bar (220psi)
Fire resistance
The system does not stroke or propagate any fires
Vacuum
Inert Gases
EXTRUDED ALUMINUM
CHEMICAL COMPOSITION
DESIGNATIONS UNI EN 573 - 3
HEAT TREATMENT
SURFACE TREATMENT
SPECIFIC WEIGHT
SPECIFIC RESISTANCE
THERMAL CONDUCTIVITY
EXPANSION COEFFICENT
SPECIFIC HEAT AT 100C (212F)
BEARING TENSILE STRESS
COEFFICENT OF ELASTICITY
PROPORTIONALITY DEVIATION LOAD
BRINELL HARDNESS
MELTING POINT
PERCENTANGE ELONGATION
Pressure
Weight
Length
mm
(in.)
bar / PSI
lbs./ft.
ft.
20
(0.75")
15 / 220
0.159
16'
25
(1")
15 / 220
0.202
16'
32
(1.25")
15 / 220
0.262
16'
40
(1.5")
15 / 220
0.331
16'
50
(2")
15 / 220
0.592
16'
63
(2.5")
15 / 220
0.623
16'
INSTALLATION OF PIPING
1
Diameter
Torque
20
25
32
40
Torque
50
63
Before pressurizing a piping system, please read and fully understand the requirements of the INFINITY TEST PROCEDURE. Failure to
comply with the requirements of the test procedure could lead to serious injury or property damage.
An INFINITY TEST PROCEDURE document is provided with every shipment of parts and can also be dowloaded from our website www.appliedsystemtech.com
CFM
CFM
CFM
CFM
(in.)
@ 125psi
@ 150psi
@ 175psi
@ 220psi
20mm
(0.75")
36
39
42
48
25mm
(1")
76
81
88
99
32mm
(1.25")
146
158
171
189
40mm
(1.5")
266
291
310
348
50mm
(2")
476
526
565
627
63mm
(2.5")
881
965
1047
1153
mm
Flow rates are based on a 1psi pressure drop per 100ft run of pipe and couplings in a straight line.
For loop systems, flow rates can be doubled.
Example:
100ft run of 2" pipe flows 476cfm at 125psig with a pressure drop of 1psig. If a system is designed in a loop configuration, a flow of 952cfm with a
pressure loss of 1psig per 200ft of piping and couplings can be achieved. The 1psi pressure loss will only occur if the compressor system is flowing
the maximum flow capacity of the piping selected.
Flows are measured at standard atmospheric conditions: 1013mbar (14.7psi) at 20C - (68F).
It is vital that the size of the piping between the compressors and the connection of the loop system can flow the full capacity of the combined
compressor output.
Testing
Infinity tube fittings are tested in accordance with the requirements of ANSI B31.1 (American National Standards Institute) Power Piping Systems.
All Infinity products have been tested and exceed the requirements of ANSI B31.1.
Infinity product provides a 5X safety factor above recommended safe working pressure/temperatures.
Pressure
Weight
Length
Part Number
mm
(in.)
psi
cfm
lbs./ft.
ft.
20
(0.75")
220
36
0.159
16
9000-20-AIR-BLUE
25
(1")
220
76
0.202
16
9000-25-AIR-BLUE
32
(1.25")
220
146
0.262
16
9000-32-AIR-BLUE
40
(1.5")
220
266
0.331
16
9000-40-AIR-BLUE
50
(2")
220
476
0.592
16
9000-50-AIR-BLUE
63
(2.5")
220
881
0.623
16
9000-63-AIR-BLUE
Pressure
Weight
Length
Part Number
(in.)
psi
cfm
lbs./ft.
ft.
20
(0.75")
220
36
0.159
16
9000-20-VAC-GREY
25
(1")
220
76
0.202
16
9000-25-VAC-GREY
32
(1.25")
220
146
0.262
16
9000-32-VAC-GREY
40
(1.5")
220
266
0.331
16
9000-40-VAC-GREY
50
(2")
220
476
0.592
16
9000-50-VAC-GREY
63
(2.5")
220
881
0.623
16
9000-63-VAC-GREY
Pressure
Weight
Length
Part Number
(in.)
psi
cfm
lbs./ft.
ft.
20
(0.75")
220
36
0.159
16
9000-20-GAS-BLACK
25
(1")
220
76
0.202
16
9000-25-GAS-BLACK
32
(1.25")
220
146
0.262
16
9000-32-GAS-BLACK
40
(1.5")
220
266
0.331
16
9000-40-GAS-BLACK
50
(2")
220
476
0.592
16
9000-50-GAS-BLACK
63
(2.5")
220
881
0.623
16
9000-63-GAS-BLACK
20
0.5"
14
32.5
34.5
56
22
30
90011-20-08
25
0.75"
16.5
38.5
42.5
66
27
35
90011-25-12
32
1"
19
46
52
76.5
34
45
90011-32-16
CH1
CH2
Part Number
40
1.5"
21.5
52
63
89.5
45
55
90011-40-24
50
1.5"
21.5
63.5
73
105
50
65
90011-50-24
63
2"
24
75.5
92
124
65
70
90011-63-32
* Threads in npt.
Other dimensions are measured in mm.
CH1
CH2
Part Number
20
32.5
12.5
34.5
76.5
21
30
90040-20
25
38.5
13.5
42.5
90.5
26
35
90040-25
32
46
14.5
52
106.5
32
45
90040-32
40
52
21
63
125
41
55
90040-40
50
63.5
21.5
73
148.5
50
65
90040-50
63
75.5
25
92
176.5
65
70
90040-63
CH1
CH2
Part Number
20
32.5
18
34.5
51
21
30
90130-20
25
38
23
42.5
61.5
26
35
90130-25
32
46
28
52
74.5
34
45
90130-32
40
52
34
63
86.5
41
55
90130-40
50
63.5
40.5
73
104
50
65
90130-50
63
75.5
52
92
127.5
65
70
90130-63
Inches
Part Number
20
.75
90140-20
25
90140-25
32
1.25
90140-32
40
1.5
90140-40
50
90140-50
63
2.5
90140-63
C1
C2
L1
L2
CH1
CH2
Part Number
20
34.5
32.5
32.5
21.5
98
54.5
21
30
90230-20
25
42.5
38
37.5
26
113.5
65
26
35
90230-25
32
52
46
46.5
31.5
138.5
77
34
45
90230-32
40
63
52
55.5
38
159.5
90
41
55
90230-40
50
73
63.5
69
44.5
196
108
50
65
90230-50
63
92
75.5
87
55.5
238.5
131
65
70
90230-63
L1
L2
CH
CH1
CH2
Part Number
34.2
98
54.5
21
21
30
90235-20-20
34.5
121.5
59
35
35
30
90235-25-20
52
34.5
146.5
63
45
45
30
90235-32-20
52
42.5
146.5
70
45
45
35
90235-32-25
D1
D2
B1
B2
C1
C2
E1
E2
20
20
32.5
32.5
32.5
21.5
34.5
25
20
38
32.5
45.5
26.5
42.5
32
20
46
32.5
54.5
30.5
32
25
46
38
54.5
31.5
40
20
52.5
32.5
60
33.5
63
34.5
165.5
66
55
55
30
90235-40-20
40
25
52.5
38
60
34.5
63
42.5
165.5
87
55
55
35
90235-40-25
50
20
63.5
32.5
73.5
40.5
73
34.5
201
73
65
65
30
90235-50-20
50
25
63.5
38.5
73.5
41
73
42.5
201
80
65
65
35
90235-50-25
50
32
63.5
46
73.5
41
73
52
201
87.5
65
65
45
90235-50-32
63
20
77
32.5
86
48.5
92
34.5
237.5
81
80
70
30
90235-63-20
63
25
77
38.5
86
49
92
42.5
237.5
88
80
70
35
90235-63-25
63
32
77
46
86
49
92
52
237.5
95.5
80
70
45
90235-63-32
This fitting is also an alternative to a traditional goose neck (up and over) take-off point. It prevents water from dropping out of the main piping loop into the
drop line. All systems should be installed with a slight gradient to allow moisture to collect at one point in the system. This point should be fitted with a drop
line and terminated with a condensate drain.
Tube mm
Outlet mm
Out-Inches
Part Number
32
20
.75
90240-32-20
32
25
90240-32-25
40
20
.75
90240-40-20
40
25
90240-40-25
50
20
.75
90240-50-20
50
25
90240-50-25
63
20
.75
90240-63-20
63
25
9240-63-25
Part Number
32-40
90241-32-40
50-63
90241-50-63
Tube mm
Part Number
32
90242-32
40
90242-40
50
90242-50
63
90242-63
L1
L2
CH1
CH2
Part Number
25
38
42.5
57.5
72
32
35
90260-25
32
46
52
67.5
82
38
45
90260-32
40
52
63
77
91.5
50
55
90260-40
50
63.5
73
86.5
101
55
65
90260-50
63
75.5
92
100.5
115
65
70
90260-63
L1
L2
Part Number
35
51
35
40
22
21
30
90601-20-08
23 42.53
62
39
40
22
26
35
90601-25-08
28
41
40
22
34
45
90601-32-08
20
25
0.5"
38
32
0.5"
46
52
74.5 48.5
* Threads in npt.
Other dimensions are measured in mm.
CH2
Part Number
20
33
34.5
30
90610-20
25
39
42.5
35
90610-25
32
46.5
52
45
90610-32
40
53
63
55
90610-40
50
62
73
65
90610-50
63
74.5
92
70
90610-63
Body
25
32
32
40
40
40
50
50
50
63
63
Outlet mm
20
20
25
20
25
32
25
32
40
40
50
Body
Inches
20mm x .5 npt male
20mm x .75 npt male
25mm x .5 npt male
25mm x .75 npt male
25mm x 1 npt male
32mm x 1 npt male
32mm x 1.5 npt male
40mm x 1.5 npt male
50mm x 1.5 npt male
50mm x 2 npt male
63mm x 2 npt male
63mm x 2.5 npt male
Out-Inches
.75
.75
1
.75
1
1.25
1
1.25
1.5
1.5
2
Part Number
90620-25-20
90620-32-20
90620-32-25
90620-40-20
90620-40-25
90620-40-32
90620-50-25
90620-50-32
90620-50-40
90620-63-40
90620-63-50
Part Number
90626-20-08M
90626-20-12M
90626-25-08M
90626-25-12M
90626-25-16M
90626-32-16M
90626-32-24M
90626-40-24M
90626-50-24M
90626-50-32M
90626-63-32M
90626-63-40M
Inches
Part Number
20
0.5
90626-20-08
Tube mm
Inches
Part Number
20
.75
90700-20
25
90700-25
32
1.25
90700-32
40
1.5
90700-40
50
90700-50
63
2.5
90700-63
B1
CH
Part Number
14
17
58
26
82600-08-08
NPTf
0.5"
* Threads in npt.
Other dimensions are measured in mm.
Part Number
0.5"
86300-08-08
0.5"
86310-08-08
Tube mm
Inches
Part Number
20
.75
90810-20-PK-10
25
90810-25-PK-10
32
1.25
90810-32-PK-10
40
1.5
90810-40-PK-10
50
90810-50-PK-10
63
2.5
90810-63-PK-10
pkg 10
Part Number
90831-15
10
Tube mm
Inches
Part Number
20
.75
90810-20-PK10-W
25
90810-25-PK10-W
32
1.25
90810-32-PK10-W
40
1.5
90810-40-PK10-W
50
90810-50-PK10-W
63
2.5
90810-63-PK10-W
90810 1/2 Deep Wall Spacer Kit (for use with both hanging/Strut & Flush Wall Bracket)
Part Number
1/2 Deep Wall Spacer
90810-SP-PK-10
Part Number
4.75"
8.25"
90830
80191-04
80191-06
80191-08
11
80193-06
80193-08
80221 Plug
Part Number
1/4 NPT Male
80221-04
80221-06
80221-08
80222 Plug
Part Number
1/4 NPT Female
80222-04
80222-06
80222-08
80223 Plug
Part Number
1/4 Hose Barb
80223-04
80223-06
80223-08
90870
90880
12
PMZR PowerMizer
Flow Rate
Part Number
75scfm
PMZR-75
200 scfm
PMZR-200
1000 scfm
PMZR-1000
Flow Rate
Part Number
200
ZLD-200
ZLD-500
2000
ZLD-2000
5000
ZLD-5000
18000
ZLD-18000
53000
ZLD-53000
90900-04
90900-08
90601-MFD
90601-G
90610 Plugs
Part Number
O ring sealed plugs
13
90610-08-NPT
10 YEAR GUARANTEE
Applied System Technologies warrants its Infinity pipe and fitting components to be
free of leaks due to manufacturing defects for a period of 10 years from date of sale. This Express
warranty is in lieu of and excludes all other warranties, guarantees or representations, express or
implied, by operation of law or otherwise, including any warranty that the materials are suitable for
the buyers requirements or special use. System must be installed by an AST approved technician.
14
Issue 3