Type Test Method Unit: Physical

The document is a data sheet that provides physical, mechanical, thermal, electrical, and flammability property information for various types of ECOTRAN PPS materials. Key information includes: - Specific gravities ranging from 1.3 to 1.98 depending on the material type - Tensile strengths between 65-195 MPa, tensile elongations of 1.2-10.1%, and flexural strengths of 100-270 MPa - Melting temperatures of approximately 280°C for all materials - Flammability ratings of V-0 or V-1 depending on the material and test method used

Uploaded by

nimonh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
741 views1 page

Type Test Method Unit: Physical

The document is a data sheet that provides physical, mechanical, thermal, electrical, and flammability property information for various types of ECOTRAN PPS materials. Key information includes: - Specific gravities ranging from 1.3 to 1.98 depending on the material type - Tensile strengths between 65-195 MPa, tensile elongations of 1.2-10.1%, and flexural strengths of 100-270 MPa - Melting temperatures of approximately 280°C for all materials - Flammability ratings of V-0 or V-1 depending on the material and test method used

Uploaded by

nimonh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ECOTRAN PPS Data Sheet

1040G

Type

Test Method

Specific gravity

Physical

Water absorption

Unit

1.66

0.02

0.02

0.02

0.03

0.02

0.02

0.3/0.5

0.3/0.5

0.2/0.6

1.2 / 1.5

0.2 / 1.3

0.2 / 1.2

1.70

ISO 527

MPa

180

195

130

65

145

145

Tensile elongation at break

ISO 527

1.7

1.8

1.2

10.1

2.5

1.5

0.34

0.35

0.30

0.38

0.35

0.35

Flexural strength

ISO 178

MPa

255

270

210

100

200

210

Flexural modulus
Charpy impact strength
(notched / un-notched)

ISO 178

MPa

12,800

13,200

18,500

2,900

9,000

12,500

ISO 179

KJ/m2

9 / 35

10 / 40

6 / 20

8 / 50

12 / 45

7 / 35

ASTM D1894

0.3 / 0.25

0.3 / 0.25

0.3 / 0.25

0.3 / 0.25

0.3 / 0.25

0.3 / 0.25

'C

265

265

265

90

255

260

1.8 x 10-5
/ 4.2 x 10-5
1.7 x 10-5
/ 10.1 x 10-5
280

1.9 x 10-5
/ 2.9 x 10-5
2.0 x 10-5
/ 6.7 x 10-5
280

6.3 x 10-5
/ 6.4 x 10-5
12.3 x 10-5
/ 14.1 x 10-5
280

2.5 x 10-5
/ 6.0 x 10-5
3.1 x 10-5
/ 9.7 x 10-5
280

2.5 x 10-5
/ 4.1 x 10-5
5.5 x 10-5
/ 9.6 x 10-5
280

Co-eff. Of friction (static / dynamic)


Distortion temp. of under load
(3.2T, @1.82 MPa)
Co-eff. Of thermal expansion
-50'C~50'C MD/TD
Co-eff. Of thermal expansion
100'C~200'C MD/TD
Melting temperature

ASTM E 831

m/m'C

ASTM E 831

m/m'C

ISO 11357

'C

2.1 X 10-5
/ 4.1 X 10-5
2.0 X 10-5
/ 9.1 X 10-5
280

UL 94

V-0

V-0

V-0

V-1 (1.5T) 1)

V-0 (1.5T) 1)

V-0 (1.5T) 1)

Dielectric strength, T=1mm/1.6mm

ASTM D149

Kv/mm

28 / 22

28 / 22

25 / 20

25 / 20

25 / 20

25 / 20

Dielectric constant (1MHz)

ASTM D150

3.8

3.8

4.8

3.5

4.8

4.8

Dissipation factor (1MHz)

ASTM D150

0.0016

0.0016

0.0016

0.0020

0.0050

0.0050

IEC 60112

Volt

150

150

225

125

150

175

ASTM D495

sec.

125

125

180

70

120

120

16

16

16

16

1016

UL flammability, T=0.4mm

Electrical

PPS E-GF50

Tensile strength
Poissons ratio

Thermal

2150T

g/cm3

Mold shrinkage MD/TD

Mechanical

PPS+GF40

1040S
5060G
2000T
2130T
PPS+GF40
PPS/GF/MF65 PPS E-unfilled PPS E-GF30
High Strength
1.66
1.98
1.30
1.50

Comparative tracking index (CTI)


Arc resistance
Volume resistibility

ASTM D257

Ohm.cm

10

10

10

16

10

10

1) : Flammability test is INITZ method