N OVA C O N T R O L S
L E A D I N G
T H E
W A Y
SystemsCompany
TOTAL ECLIPSE Quick Start Guide
for the TOTAL ECLIPSE CHEMICAL MANAGEMENT SYSTEM
The TOTAL ECLIPSE Controller is an integral part of the TOTAL ECLIPSE Chemical Management System, which also includes:
The Machine Interface Accepts washer signals and converts them to safe, low-voltage inputs.
The Pump Module Provides product transfer to the wash machine. The TOTAL ECLIPSE Controller is compatible with
any Nova Controls modular pumpstand. including the Eclipse, Orion or any of the Large Laundry dispensers.
The Flush Manifold (optional) Available for water flush chemical transfer applications.
Designed for maximum versatility in OPL or large laundry machines, the TOTAL ECLIPSE Controllers selectable Operating
Modes allow the system to work with trigger signals from fully-programmable washers or with manually triggered signals (or cycle
time extenders) from non-programmable, fixed-time washers. The Controllers easy-to-understand, plain-text LCD display (available
in a variety of languages), make operator training simple. Installation time and cost is significantly reduced with the computer based
Formula Editor program, allowing an off-site technician to create sets of up to 20 industry-specific, efficient and cost-effective
formulas that are loaded onto a controller with a customer-supplied USB flash drive (2 GB or smaller). Summary Reports can be
saved to the same USB flash drive, providing usage and programming information to effectively analyze and manage each machine.
Components Supplied
Wall Mount Bracket, Kit
(P/N 13-08462-00, Grey)
(P/N 13-08916-00, Black)
TOTAL ECLIPSE Controller
(P/N 01-08500-00, Grey/Teal)
(P/N 01-08900-00, Black/Red)
Quick Start Guide
(P/N 20-08808-00)
DOWNLOAD from the Nova Controls website (http://www.novacontrols.com):
Formula Editor Software for Windows 2000/XP/Vista, Linux & Mac OS 10.4
(Minimum requirements: Java JRE 1.5 or higher [90 MB disc space]; 1024 x 768 screen resolution; 128 MB RAM; 10 MB
disc space; USB 2.0 and a USB flash drive [2GB or smaller, FAT32 format] for data transfer to TOTAL ECLIPSE controller
Additional Language Files Two Types (for Formula Editor Software and for TOTAL ECLIPSE Controller Menus )
TOTAL ECLIPSE Complete Reference Manual at www.novacontrols.com/instructions.htm (P/N 20-08490-00)
How to Use the TOTAL ECLIPSE Quick Start Guide
Use this Quick Start Guide if you are already familiar
with installing and using dispensing systems. Please
refer to the TOTAL ECLIPSE Reference Manual for
detailed instructions, including information on the
optional Relay, Event, Occurrence and Group
Operating Modes. Refer also to the Installation and
Operations manual that is included with your
pumpstand or upgrade kit for additional instructions.
TOTAL ECLIPSE Controller Specifications
Size
Weight
Power Rating
Data Input Field Size
Pump Capacity
Environmental
Temperature
Humidity
Indoor Installation
Altitude
5.25" W x 4.0" H x 2.5" D ( 13.4 cm W x 10.2 cm H x 6.4 cm D)
0.65 lb. (0.30 kg)
SELV Power source is pumpstand
15 characters maximum input for custom names
99.99 oz. (2999 ml.) 8 pump (with 3 amount settings per pump) maximum
IP Rating 44
Pollution Category 2
Installation Category II
10 to 49 C (50 to 120 F) maximum
95% relative humidity, maximum
Approved for indoor use only. Must not be installed outdoors.
Install at or below 6,500 ft. (2000 m) maximum
IMPORTANT NOTE: Quick Start instructions
assume that Formula/Setup files will be loaded via a USB
Specifications subject to change without notice.
flash drive, which may override the following factory
default settings: Standard Operation; Eclipse Flush P.I.; Flush Time0 sec.; Cycle Time90 min.; Signal Filter Time2 sec.; User Prime Disabled;
Bleach DefeatOff; Units of Measure = SAE. Default Passwords are Installer = 01234; Manager = 0123. It is recommended that default passwords
are changed via the controllers keypad (and noted) after installation and system setup are complete. To change formulas, settings or passwords
using controller keys, or to add a machine or company name, see the Guide to Keypad and Menus (p. 5) and Initial Setup on Installer Menus (p. 6).
P/N 20-08808-00C
Copyright 2008 Nova Controls, Inc.
Installation
WARNING
ADVERTENCIA
Disconnect all power to the pumpstand during installation, service, and/or any time pump cabinet is opened. The TOTAL
ECLIPSE should be installed by a qualified technician only, in accordance with all applicable electrical and plumbing codes.
Desconecte toda la corriente elctrica al dosificador durante la instalacin, servicio y / o siempre que se abra el gabinete de la
bomba. El equipo TOTAL ECLIPSE debe ser instalado slo por tcnicos calificados y de acuerdo con todas las normas de
plomera y elctricas que apliquen.
Step 1. Install the Machine Interface (MI)
WARNING
ADVERTENCIA
Keep MI and communication cable away from high voltage wires and relays. NEVER parallel the cable with high voltage lines.
Mantenga M.I. y los cables de comunicacin separados de los cables de alta tensin y rels. NUNCA instale el cable paralelo
con las lneas de alta tensin.
1. Route MI signal wires through 1/2 inch knock-out on washer (within the wiring area).
Secure MI to washer with lock nut (provided).
2. Plug J2 cable into MI. Bundle excess J2 cable outside washer and connect other end
to J2 connector on rear of Controller.
3. Connect J1 cable from pump module to J1 connector on Controller. The maximum
distance for a J1 cable is 75 ft. (22.9 m.) unless using a break out box and hard wiring.
Contact Nova Controls for additional cables, a coupler or detailed instructions.
4. Secure J1 and J2 cables to controller tie-down posts with tie wraps.
MACHINE INTERFACE
(Front)
J2
Cable
Connection
(Rear)
Signal
Wires
TOTAL ECLIPSE Controller (Rear)
J2 Cable
J1 Cable
Step 2. Connect Signal Wires
Tie
Wraps
Voltage
The Machine Interface will work with any signal voltage between 24 240VAC or 22 24VDC. With DC signals, polarity
must be observed. Common is negative. The signals should be positive voltages.
CAUTION
Always verify all voltage sources with a meter. Electrical wiring connections for supply triggers are to be done inside the junction box.
CUIDADO
Siempre verifique la alimentacin de corriente con un voltmetro. Las conexiones elctricas a los disparadores de suministro
(supply) deben hacerse dentro del recinto donde se encuentran los suministros (supply).
Supply Trigger Wiring
Identify the washer supply signals. In Standard or
Group Mode of Operation, use appropriate terminal
connectors to connect the signal wires to the Machine
Interface wires, per table at right. (Do not use this
table for Event or Occurrence Modes; see Manual.)
Trigger Signal Wiring Notes:
Trigger
Supply
Signal
Signal
Common
Connect to:
Standard (US) Group (EU)
Signal 1
Black wire
White/Black
Pump 1
Signal 2
Brown wire
White/Brown
Pump 2
Group 1
Signal 3
Red wire
White/Red
Pump 3
Group 2
Signal 4
Orange wire
White/Orange
Pump 4
Group 2
Signal 5
Yellow wire
White/Yellow
Pump 5
Group 3
Group 1
If one or more pump signals are not used, they
Signal 6
Blue wire
White/Blue
Pump 6
Group 4
do not need to be connected.
If you are triggering more than one pump from a single signal, connect all MI signal wires for those pumps to that signal.
Wire nut unused wires. If washer has a single common, wire nut all commons together.
Step 3. Mount the Controller
1. Mount bracket with velcro-style strips, according the directions at
right. Install wall board screws or nuts and allen bolts, if needed.
2. Slide controller down onto mounting bracket until it snaps in place.
3. Install pump module and make all electrical and plumbing
connections for the system, but do not apply power to the TOTAL
ECLIPSE until you are ready to select a language of operation.
1 Attach Velcro-style Strips and Mount
2 (Optional)
Install Wall Board
Screws or Masonry
Nuts & Allen Bolts
Mounting Bracket
3 With J1 and J2 cables
connected, slide Controller
onto mounting bracket until it snaps into place.
Controller Language Options
Each TOTAL ECLIPSE controller is shipped with two languages installed: English/Spanish (Americas); English/German (EU); or
English/Simple Chinese (Asia). Additional languages may be downloaded from the Nova website directly to your USB flash drive
(2GB or smaller). If changing from a default languages, you will need your language-enabled USB flash drive for the next step.
2
P/N 20-08808-00C
Step 4. Select the Controller Menu Language (Before Applying Power)
EXIT
UP
ENTER
1. To select one of the pre-installed languages, skip to Step 2. To replace the non-English
language with a different language, connect a USB flash drive containing the new language
to the controllers USB port (under flap on right side of controller) BEFORE power-up.
LEFT
RIGHT
2. Apply power to pumpstand & power-up Controller. Each available LANGUAGE is displayed.
DOWN
3.
Move the selection box by using the UP or DOWN ARROWS until the correct
TOTAL ECLIPSE Keypad
language is contained within the box.
(Press & Hold for Auto-Key Repeat)
4.
Press Enter to select that language. All menu and application items are translated into
the new language. Text that was input by the installer remains in the original language and is not translated.
5. The Home Screen appears. You must now program the controller with formula and operational set-up files, using either a USB
flash drive or the controllers keypad.
Step 5. Program the Controller via USB Flash Drive
The easiest way to program the controller is by loading previously created set-up files from a USB flash drive onto the controller.
Settings that are not transferred via a USB drive are: Passwords (Installer & Manager); Machine Name; Company Name; Calibration.
1. Connect the USB flash drive containing set up files that were created in either the Formula Editor or on another controller.
2.
From the Home Screen, press ENTER to launch the MAIN MENU.
3.
Move the selection box to INSTALLER MENU (last item in the MAIN MENU) by pressing and holding the DOWN ARROW.
4.
Press ENTER and input the default Installer Password of 01234, using the UP
ARROW to move the cursor.
ARROW to increment the number and the
RIGHT
Press ENTER to accept the password input. Continue with Steps 3, 4, and 5 in the sequence illustrated below.
6. Remove USB flash drive. Press EXIT
to return to the Installer Menu, in order to calibrate (required) and prime pumps
Default Home Screen
1. Select Installer Menu
2. Input Password
3. Select Data Transfer
NOVA CONTROLS
F01
MAIN MENU
INSTL PASSWORD
INSTALLER MENU
01234
EMERGENCY PUMP STOP
LOAD SIZE: 200 LB
BLEACH DEFEAT: OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
INSTALLER MENU
OK
4. Display Files on USB
DATA TRANSFER
OK
EXIT
KEY until
1. Select Installer Service
2. Select Service Pumps
3. Select Prime Pump
5. Select Pump to Prime
INSTALLER MENU
INSTALLER SERVICE
SERVICE PUMPS
SET PRIME PUMP
INSTALLER SERVICE
INITIAL SYSTEM SETUP
PROGRAM FORMULAS
DATA TRANSFER
SET UNITS OF MEASURE
SERVICE PUMPS
VIEW LOAD COUNT
VIEW LOAD WEIGHT
VIEW AMOUNT PUMPED
CLEAR DATA LOG
PRIME PUMP
PUMP CALIBRATION
NAME PUMPS
ENTER PRODUCT COSTS
DATE TUBE CHANGED
POG Restaurants
BLS Services
Eclipse Hotel
Hospital Settings
International Hotel
AA School District
WRITE REPORTS
READ SETUP
WRITE SETUP
UPDATE FIRMWARE
INSTALLER SERVICE
INITIAL SYSTEM SETUP
PROGRAM FORMULAS
DATA TRANSFER
SET UNITS OF MEASURE
Step 6. Prime Pumps
to start and stop prime. After priming is complete, press the EXIT
Press Enter
5. Send File to Controller
SETUP FILE
5.
EXIT
you reach the Home Screen.
6. Start/Stop Prime
PRIME
P2
P1
P2
P3
P4
P5
P6
START/STOP
EXIT
Step 7. Calibrate Pumps
You must calibrate all pumps that will be used in a formula. Programmed formulas will not run if pumps are not calibrated.
Use CALIBRATE (VOLUME) only for medium (12 or 18 oz. / 355 or 532 ml. per minute) pumps.
2. Select Service Pumps
INSTALLER MENU
INSTALLER SERVICE
INSTALLER SERVICE
INITIAL SYSTEM SETUP
PROGRAM FORMULAS
DATA TRANSFER
SET UNITS OF MEASURE
SERVICE PUMPS
VIEW LOAD COUNT
VIEW LOAD WEIGHT
VIEW AMOUNT PUMPED
CLEAR DATA LOG
3. Select Pump Calibration
SERVICE PUMPS
PRIME PUMP
PUMP CALIBRATION
NAME PUMPS
ENTER PRODUCT COSTS
DATE TUBE CHANGED
Use CALIBRATE (TIME) for large displacement pumps or
for a flush installation. Press START
and the timer
counts down 20 seconds. DO NOT stop the pump; run it
for a full 20 seconds, then enter the amount pumped.
P/N 20-08808-00C
4. Select Calibration Method
PUMP CALIBRATION
VIEW CALIBRATION
CALIBRATE (TIME)
CALIBRATE (VOLUME)
5. Select Pump to Calibrate
CALIBRATE (TIME)
P1
P2
P3
P4
P5
P6
5. Select Pump to Calibrate
CALIBRATE (VOL.)
P1
P2
P3
P4
P5
P6
P2
STOP PUMP AT 8 OZ
WARNING! PLACE
CONTAINER AT OUTPUT!
START/STOP
EXIT
6. Run Pump Full 20 Seconds
CALIBRATE
P2
6. Collect 8 oz [250 ml]
CALIBRATE
20.0
0.0
WARNING! PLACE
CONTAINER AT OUTPUT!
START/STOP
EXIT
6.1 Input Amount Collected
DISPENSED VOLUME
ENTER AMOUNT PUMPED
00.0 OZ
1. Select Installer Service
OK
EXIT
Home Screen
The Home Screen appears after the controller language has been selected or whenever the controller is active. If no key is pressed
for 15 minutes, Power Save turns off the displays backlight. Press any key to turn the backlight on and resume normal operation.
If the controller is powered off, the last formula selected is the active formula on the Home Screen when power is turned back
on. See the following graphic for an explanation of the information and symbols that may appear on the Home Screen.
Home Screen
Company Name (can be changed during System Setup)
NOVA CONTROLS
F03 TOWELS
Current Formula (or Next Formula to Run)
(Formula number appears if no name is input during System Setup)
NON-ACTIVE Pump Not programmed or calibrated; not in formula
Pumps
1 2 _
Trigger
Signals
5 6
_ 2 _ 4 _ _
ACTIVE Pump Currently running
READY Pump Calibrated and has amount(s) programmed
ERROR in Pump Amount(s) programmed; not calibrated
Non-Active
Signal
Qualified
Signal
Receiving
Signal
(unqualified)
Hot Keys: Formula Quick-Select
Main Menu
Formula Quick-Select
To prevent errors in data logging or chemical dispensing: Select the correct formula before
washer operation starts and be sure that all programmed pumps are triggered during the cycle.
From the Home Screen, press the EXIT key (also called FORMULA SELECT).
1.
2.
Press the UP or DOWN ARROW to move the selection box to the correct formula.
All formulas appear, but only formulas with programmed pumps are selectable.
3.
Press ENTER to start the formula and return to the Home Screen.
4. (Optional) Press ENTER
to reach the load size or bleach defeat settings.
Main Menu
Formula Quick-Select
NOVA CONTROLS
F03 TOWELS
1 2
_ _
SELECT FORMULA
FO1 PADS
F02 CURTAINS
FO3 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
To reach the Main Menu from the Home Screen, press any key (except the EXIT key).
Move Box
Main Menu
MAIN MENU
EMERGENCY PUMP STOP
LOAD SIZE
075 LB
BLEACH DEFEAT
OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
INSTALLER MENU
Emergency Pump Stop (stops all pumps and formulas)
Bleach Defeat Menu (default is OFF)
Load Size Menu (displays default load weight for formula.
Input actual weight at start of each load).
Selection Box Move box to select menu item.
Press ENTER
Select Formula
to launch selected menu
More Items Available (move Selection Box to view additional menus)
Return to Home Screen: Press EXIT
or wait 15 seconds without pressing a key.
Limited Warranty
SELLER warrants solely to BUYER the Products will be free from defects in material and workmanship under normal use and service for a period of one year
from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) and products that have a normal life shorter than one year; or
(c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the Products are altered or repaired by BUYER without SELLERS prior written approval, all warranties will be void. NO OTHER WARRANTY, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE, IS MADE FOR THESE PRODUCTS, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY EXCLUDED.
SELLERS sole obligation under this warranty will be, at SELLERS option, to repair or replace F.O.B. SELLERS facility in Watsonville, California any Products
found to be other than as warranted.
Limitation of Liability
SELLERS WARRANTY OBLIGATIONS AND BUYERS REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED HEREIN. SELLER SHALL HAVE
NO OTHER LIABILITY, DIRECT OR INDIRECT, OF ANY KIND, INCLUDING LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES OR FOR ANY OTHER CLAIMS FOR DAMAGE OR LOSS RESULTING FROM ANY CAUSE WHATSOEVER, WHETHER BASED ON
NEGLIGENCE, STRICT LIABILITY, BREACH OF CONTRACT OR BREACH OF WARRANTY.
P/N 20-08808-00C
TOTAL ECLIPSE Operator Menus
Home Screen
Formula Select
Guide to Keypad & Menus
SELECT FORMULA
NOVA CONTROLS
F02 CURTAINS
123X56788
_ 2 _ _ _ _
Main Menu
F01 PADS
F02 CURTAINS
F03 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
Select
& Return
to Home
Screen
SELECTION
BOX
EMERGENCY STOP
350 LBS =
STOP ALL PUMPS
AND FORMULAS
STOP
EDIT
VALUE
UP/DOWN
LEFT/RIGHT
Arrows Input Arrows Move
Value (0-9, A-Z)
Cursor
MENU
SYMBOLS
Input Actual Load Weight
LOAD WEIGHT
MAIN MENU
HOME
SCREEN
220 LB
F02
FO3
FO4
More Items
Installer Menu Access
Bleach Defeat On/Off (Default Off)
MAIN MENU
OFF
ON
LOAD SIZE
180 LB
BLEACH DEFEAT
OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
INSTALLER MENUS
(SINGLE LOAD)
OK
EXIT
Select Pump to Prime (if enabled)
01234
P3 LIQUID BLEACH
OK
START/STOP
EXIT
EXIT
MANUAL FLUSH
EXIT
Input Manager Password
MGR PASSWORD
0123
OK
Set Date for Report Header
Set SAVE AS File Name & Date
REPORT DATE
REPORT NAME
00-00-00
EMERGENCY PUMP STOP
LOAD SIZE
220 LB
BLEACH DEFEAT
ON
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
Start/Stop Flush (if flush enabled)
START/STOP
Main Menu (Manager Reports)
PRIME
WASH23 12-10-08
EMERGENCY PUMP STOP
LOAD SIZE
220 LB
BLEACH DEFEAT
ON
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
P1 PRE-WASH
P2 DETERGENT
P3 LIQUID BLEACH
P4 BLEACH ALTERNATIVE
P5 SOUR/CONDITI
P6 ENZYME LIFT
INSTL PASSWORD
Start / Stop Prime Pump
EXIT
OK
Main Menu (User Manual Flush)
Trigger Signal Icon
(SINGLE LOAD)
OK
EXIT
SET PRIME PUMP
MAIN MENU
EMERGENCY PUMP STOP
LOAD SIZE
220 LB
BLEACH DEFEAT
ON
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
Pumping &
Flushing
Main Menu (User Prime Pump)
Flushing
Pump Icon
BLEACH DEFEAT
EMERGENCY PUMP STOP
LOAD SIZE
220 LB
BLEACH DEFEAT OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
Steady On
Pumping
(Flush Off)
Main Menu (Bleach Defeat)
EXIT
Only
MAIN MENU
EMERGENCY PUMP STOP
LOAD SIZE
275 LB
BLEACH DEFEAT OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
ENTER
Saves
& Exits
EXIT
INSTALLER MENUS
Main Menu
or
EMERGENCY PUMP STOP
LOAD SIZE
275 LB
BLEACH DEFEAT OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
MAIN MENU
ENTER also
Starts/Stops
Action
Emergency Pump Stop
MAIN MENU
MAIN MENU
UP/DOWN
ENTER Key
Arrows Move
Launches
Selection Box Menu Item
EXIT
INSERT USB DRIVE
OK
EXIT
Display returns to Main Menu after data transfer is complete.
P/N 20-08808-00C
_ _
SAE / IMPERIAL (LB/OZ)
METRIC (KG/ML)
UNITS-MEASURE
5. Set Units of Measure
WRITE REPORTS
READ SETUP
WRITE SETUP
UPDATE FIRMWARE
DATA TRANSFER
4. Upload / Download Data
F01
F02 CURTAINS
F03 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
PROGRAM FORMULAS
3. Formula Programming
SET PUMP INTERFACE
SET CYCLE TIME
SIGNAL FILTER TIME
SET AFS TRIGGER
SET USER PRIME
SET LCD CONTRAST
CLEAR SETTINGS
VIEW SOFTWARE ID
EDIT INST PASSWORD
EDIT MGR PASSWORD
OPERATION MODE
EDIT ACCOUNT NAME
EDIT MACHINE NAME
EDIT COMPANY NAME
SYSTEM SETUP
2. Initial System Setup
EXIT
01234
EXIT
OK
01-01-08
EXIT
REPORT DATE
01234
OK
EXIT
0123
2.2 Edit Manager Password
MGR PASSWORD
F01 PADS
F02 CURTAINS
F03 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
HI-CAP 01-01-08
OK
EXIT
INSERT USB DRIVE
EXIT
P1
P1A
P1B
P1C
0 0 0 SEC
00.00 OZ
00.00 OZ
00.00 OZ
EXIT
OK
Overwrites ALL settings &
formulas, except passwords,
machine name, company
name & calibrations.
EXIT
EXIT
P2 DETERGENT
P3 LIQUID BLEACH
P4 BLEACH ALT
P5 SOUR/CONDITI
P6 ENZYME LIFT
P7
3.3 Set Count Pump
F01 COUNT PUMP
OK
50
2.12 Adjust Screen Contrast
LCD CONTRAST
OK
HOUSEKEEPING 01
HOTEL 17
SETUP NAME
EXIT
Overwrites le of same
name on USB ash drive.
Does not transfer passwords,
machine name, company
name or calibrations.
OK
INSERT USB DRIVE
EXIT
EXIT
EXIT
EXIT
OK
EXIT
STOP!!! DO NOT
PROCEED WITHOUT
PC UPDATE PROGRAM!
UPDATE FIRMWARE
4.4 Update Firmware
OK
NEW NAME
3.4 Edit Formula Name
NAME F01
OK
WARNING! ALL SETUPS
WILL BE CLEARED TO
FACTORY DEFAULTS!
2.13 Clear Controller Settings
CLEAR SETTINGS
OK
NOVA CONTROLS
2.6 Edit Company Name
COMPANY NAME
OK
WARNING! ALL LOGS
(LOADS & VOLUMES)
WILL BE CLEARED!
ZERO DATA LOG
1.5 Clear Data Log
4.3 Write Setup - Name File being sent
(from Controller to USB flash drive)
EXIT
0 0 0 LB
3.2 Default Load Weight
F01 LOAD SIZE
OK
DISABLE
ENABLE
LIMITED 30 SEC
SETUP FILE
POG Restaurants
BLS Services
Eclipse Hotel
Hospital Settings
International Hotel
AA School District
EXIT
2.11 User Prime Enable
SET USER PRIME
OK
0.0
0.0
0.0
0.0
0.0
0.0
2.5 Edit Machine Name
MACHINE NAME
P1 PRE-WASH
P2 DETERGENT
P3 LIQUID BLEAC
P4 BLEACH ALT
P5 SOUR/CONDITI
P6 ENZYME LIFT
HOTEL ECLIPSE - 67
4.2 Read Setup - Select File to
load from USB to Controller
DELAY
AMOUNT
AMOUNT
AMOUNT
F01 P1
3.1.3 Pump Settings
(0 = OFF)
OK
REPORT NAME_DATE
4.1.2 Set SAVE AS
File Name & Date
P1 PRE-WASH
P2 DETERGENT
P3 LIQUID BLEACH
P4 BLEACH ALT
P5 SOUR/CONDITI
P6 ENZYME LIFT
3.1.2 Add Pumps to Formula
F01 PUMPS
2 SECONDS
10 SECONDS
20 SECONDS
30 SECONDS
60 SECONDS
90 SECONDS
2.10 Auto-Formula Select
AFS TRIGGER
STANDARD
RELAY
EVENT
GROUP
OCCURRENCE
0
0
0
0
0
0
PUMPED (GAL)
1.4 View Amount Pumped
2.4 Edit Account Name
ACCOUNT NAME
F01 PADS
F02 CURTAINS
F03 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
TOTAL WEIGHT
1.3 View Load Weight
INSTALLER SERVICE
INITIAL SYSTEM SETUP
PROGRAM FORMULAS
DATA TRANSFER
SET UNITS OF MEASURE
INSTALLER MENU
Installer Top Level Menu
2.3 Set-up Operating Mode
OPERATION MODE
0
0
0
0
0
0
TOTAL LOAD COUNT
1.2 View Load Count
OK
EXIT
INSTL PASSWORD
Input Installer Password
2.9 Set Trigger Signal Filter
TRIGGER FILTER
4.1 Set Date for Report Header
PUMP SETTINGS
SET DEFAULT WEIGHT
SET COUNT PUMP
EDIT NAME
CLEAR FORMULA
3.1 Set Formula
F01
OK
(0 = OFF)
9 0 MINUTES
2.8 Set Cycle Time Limit
CYCLE TIME LIMIT
OK
2.1 Edit Installer Password
INST PASSWORD
PRIME PUMP
PUMP CALIBRATION
NAME PUMPS
ENTER PRODUCT COSTS
DATE TUBE CHANGED
SERVICE PUMPS
INSTALLER SERVICE
SERVICE PUMPS
VIEW LOAD COUNT
VIEW LOAD WEIGHT
VIEW AMOUNT PUMPED
CLEAR DATA LOG
1.1 Pump Maintenance /Service
1. Service / Routine Maintenance
_ 2 _ 4 _ _
1 2 3
LOAD SIZE:
175 LB
BLEACH DEFEAT: OFF
USER PRIME PUMPS
USER MANUAL FLUSH
MANAGER REPORTS
INSTALLER MENUS
MAIN MENU
Main Menu
NOVA CONTROLS
F03 TOWELS
225 Westridge Drive, Watsonville, California, USA 95076-4168
8 3 1 . 7 8 6 . 1 4 7 0 8 0 0 . 2 5 2 . N OVA ( 6 6 8 2 ) FA X : 8 3 1 . 7 8 6 . 1 6 5 2
www.novac ont rols.c om
Home Screen
(factory default settings shown in selection boxes)
TOTAL ECLIPSE Top Level Installer Menus
Systems Company
W A Y
T H E
L E A D I N G
N OVA C O N T R O L S
P/N 20-08808-00C
EXIT
DO NOT attempt firmware
update unless you have your
PC Update Program and
proper computer cable.
WARNING!
OK
WARNING! FORMULA
WILL BE CLEARED TO
FACTORY DEFAULT!
3.5 Clear Formula
CLEAR F01
TOTAL ECLIPSE
P / N : 95-08489-00A
REV: 687
2.14 Software Version ID
SOFTWARE VER
NON-FLUSH
ECLIPSE FLUSH P. I.
ORION I I FLUSH P. I.
8-PUMP FLUSH P. I.
2.7 Set Pump Interface
(and Flush Time, if needed)
PUMP INTERFACE
Enter / Save Key
- Launches selected menu item
- Saves changes & exits menu
Right / Left Arrow
During input, moves the
cursor ( ) to the next digit
Up / Down Arrow
- Moves Selection Box
- Changes digit value