PCS7 License
PCS7 License
Licensing of PC stations
Data volumes
SIMATIC
Process Control System PCS 7
Licenses and quantity structures
(V8.0)
Installation Manual
05/2012
A5E03805083-02
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified
personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when working with these products/systems.
Trademarks
All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NRNBERG
GERMANY
A5E03805083-02
07/2013 Technical data subject to change
Table of contents
1
Preface.........................................................................................................................................................5
Licensing of PC stations.............................................................................................................................11
3.1
3.2
3.3
3.4
3.5
Data volumes..............................................................................................................................................21
4.1
4.2
4.3
Index...........................................................................................................................................................27
Preface
Purpose of this documentation
This documentation describes the licensing for the process control system PCS 7.
The following topics are described:
Selecting the correct licenses, referred to as license keys, for different PCS 7 software
products.
PCS 7 software packages and the required license keys.
Preface
Introduction
The configurable size of a PCS 7 plant is scalable. The software product licenses for
engineering station, operator station, SIMATIC BATCH station, route control station and
SIMATIC PDM are licensed as follows:
Basic license depends on the version and activates the functionality, e.g. redundant OS
server
License for the scalable size; has the "Count Relevant License" type and determines the
quantity structure of this functionality, for example, OS runtime 1000 PO
With licenses of the type "Count Relevant License", you can install several license keys
whose licensed values are then added up.
Process object
The following applies for licensing of the "PO" process objects in SIMATIC PCS 7 V 8.0:
The following are counted as PCS 7 process object:
all SFC
all block instances that meet the following criteria:
they can be operated and monitored.
they generate alarms.
they are not components of the driver library.
These are the objects that are transferred to the OS and require licenses.
A block with operator control and monitoring has the attribute "S7_m_c = true" in the
CFC block properties.
A process object can include the following blocks and objects:
Blocks for operating and monitoring a system
Objects for automation
Objects for signal recording and signal processing
You can find additional information on process objects in the manual Process Control System
PCS 7; Engineering System, for example in the section "Counting and booking of process
object licenses".
Levels of licenses
The following table shows the available system size increments (for each component of the
process control system).
Component of process
control system
Levels of licenses
PO:
100
1000
10000
PO:
100
1000
5000
Archive values:
1500
5000
10000
30000
Process Historian
Comment
Archive values:
1500
5000
10000
30000
Information Server
Clients:
3
10
Asset tags
(hardware components):
Maintenance Station
(MS)
100
1000
PCS 7 OS Web Option
Web clients:
5
10
BATCH stations (batch
processes)
Units:
1
10
50
Component of process
control system
Levels of licenses
Comment
Routes:
10
50
PDM
Number of devices:
10
100
1000
See also
Software and license keys for configuration with PCS 7 (Page 11)
Software and license keys for a single-station system with configuration (Page 13)
Software and license keys for Operator Stations (Page 15)
Software and license keys for BATCH Stations (Page 18)
Software and license keys for Route Control Stations (Page 19)
Licensing of PC stations
3.1
Overview
The following tables show the software packages and the required license keys for the
engineering station of PCS 7:
You can find information on license key levels in section "Selecting the correct license keys
(Page 7)".
Note
The versions for the current program package on the DVD Process Control System; SIMATIC
PCS 7can be found in the Process Control System PCS 7; PCS 7 Readme file.
Engineering station
Designation
License key
AS/OS engineering
AS Engineering
Optional
Comment
OS Engineering
Runtime license AS
AS RT PO
BATCH Engineering
Route Control
Engineering
Maintenance Station
Engineering
Maintenance ES
PDM
PDM Basic
PDM TAG
S7 PLC simulation
S7-PLCSIM
Version Trail
Version Trail
Import/Export Assistant
IEA
11
Licensing of PC stations
3.1 Software and license keys for configuration with PCS 7
Designation
License key
Optional
Advanced Engineering
System
AdvancedES
SIMATIC NET
1. BCE
(1. + 2.)
alternative
2. Industrial Ethernet
3. S7-REDCONNECT
(3.) X
Comment
12
Licensing of PC stations
3.2 Software and license keys for a single-station system with configuration
3.2
Overview
The following tables show the software packages and the required license keys for a singlestation system in PCS 7 with configuration.
The single-station system includes the Engineering Station and the Operator Station (singlestation system) as basic functions.
The following can be installed as optional functions, for example:
BATCH Station (single-station system)
Route Control (single-station system)
Maintenance Station (single-station system)
PDM
You can find information on license key levels in section "Selecting the correct license keys
(Page 7)".
Note
The versions for the current program package on the DVD Process Control System; SIMATIC
PCS 7can be found in the Process Control System PCS 7; PCS 7 Readme file.
Single-station system
Designation
License key
AS/OS engineering
AS Engineering
Optional
Comment
OS Engineering
Runtime license AS
AS RT PO
OS software single
station
Runtime License OS
OS RT PO
max. 2000 PO
Count relevant license
OS/PH archive
WinCC Archive
BATCH single-station
package
BATCH units
BATCH Units
Route Control
Engineering
restricted to 30 routes;
max. 300 simultaneous
material transfer operations
13
Licensing of PC stations
3.2 Software and license keys for a single-station system with configuration
Designation
License key
Optional
Comment
Maintenance Station
Engineering
Maintenance ES
Maintenance Station
Runtime Basic Package
Maintenance RT
PDM
PDM Basic
PDM TAG
S7 PLC simulation
S7-PLCSIM
Version Trail
Version Trail
Import/Export Assistant
IEA
SIMATIC NET
1. BCE
(1. + 2.)
alternative
2. Industrial Ethernet
3. S7-REDCONNECT
(3.) X
14
Licensing of PC stations
3.3 Software and license keys for Operator Stations
3.3
Overview
The following tables show the software packages and the required license keys for the following
PC stations of PCS 7:
Operator Station (single-station system / redundant single-station system)
Operation Station server/redundant server
Operator Station Client
You can find information on license key levels in section "Selecting the correct license keys
(Page 7)".
Note
The versions for the current program package on the DVD Process Control System; SIMATIC
PCS 7can be found in the Process Control System PCS 7; PCS 7 Readme file.
License key
Optional
Comment
OS software single
station
OS software single
station redundancy
OS Single Station
Redundancy
Runtime License OS
OS RT PO
max. 5000 PO
OS/PH archive
WinCC Archive
StoragePlus
OS StoragePlus
OpenPCS 7 for
connecting to the local
OPC server
OpenPCS 7 Station / OS
Web Server
or
OpenPCS 7 Station
2. OS Web Server
15
Licensing of PC stations
3.3 Software and license keys for Operator Stations
Designation
License key
Optional
Comment
WebDiagnose Server
WebDiagnose Client
SIMATIC NET
1. BCE
(1. + 2.)
alternative
2. Industrial Ethernet
3. S7-REDCONNECT
(3.) X
License key
Optional
Comment
OS software server
OS Server
OS software server
redundancy
OS Server Redundancy
Runtime License OS
OS RT PO
max. 8500 PO
OS/PH archive
WinCC Archive
StoragePlus
OS StoragePlus
BATCH server
BATCH Server
BATCH units
BATCH Units
OpenPCS 7 for
connecting to the local
OPC server
OpenPCS 7 Station / OS
Maintenance Station
Runtime Basic Package
Maintenance RT
SIMATIC NET
1. BCE
(1. + 2.)
alternative
2. Industrial Ethernet
3. S7-REDCONNECT
(3.) X
16
Licensing of PC stations
3.3 Software and license keys for Operator Stations
OS client
Designation
License key
OS software client
OS Client
Web server
Optional
Comment
2. OS Web Server
WebDiagnose Server
WebDiagnose Client
BATCH client
BATCH Client
SFC visualization
SFC Visualization
OpenPCS 7 Station / OS
17
Licensing of PC stations
3.4 Software and license keys for BATCH Stations
3.4
Overview
The following tables show the software packages and the required license keys for the following
PC stations of PCS 7:
BATCH server/BATCH redundant server
BATCH Client
Additional information on the single-station system for BATCH can be found in the section
"Software and license keys for a single-station system with configuration (Page 13)".
You can find information on license key levels in section "Selecting the correct license keys
(Page 7)".
Note
The versions for the current program package DVD Process Control System; SIMATIC PCS 7
can be found in the Process Control System PCS 7; PCS 7 Readme document.
License key
BATCH server
BATCH Server
BATCH units
BATCH Units
BATCH API
BATCH API
SIMATIC NET
1. BCE
(1. + 2.)
alternative
2. Industrial Ethernet
3. S7-REDCONNECT
Optional
(3.) X
Comment
BATCH Client
18
Designation
License key
BATCH client
BATCH Client
Optional
Comment
Licensing of PC stations
3.5 Software and license keys for Route Control Stations
3.5
Overview
The following tables show the software packages and the required license keys for the PC
stations of PCS 7 Route Control.
Additional information on the single-station system with Route Control can be found in Section
"Software and license keys for a single-station system with configuration (Page 13)".
You can find information on license key levels in section "Selecting the correct license keys
(Page 7)".
Note
The versions for the current program package on the DVD Process Control System; SIMATIC
PCS 7can be found in the Process Control System PCS 7; PCS 7 Readme file.
RC Server
Designation
License key
SIMATIC NET
1. BCE
2. Industrial Ethernet
3. S7-REDCONNECT
Optional
(1. + 2.)
alternative
(3.) X
Comment
RC Client
Designation
License key
Optional
Comment
The license for RC client is
either located directly on the
client or, alternatively, on the
ES.
19
Data volumes
4.1
Introduction
The section describes the following PCS 7-specific quantity structures:
Automation systems
Operator Station
Additional information
Information on the quantity structure of SIMATIC BATCH can be found in the manual
SIMATIC BATCH in the section "Product introduction and installation > Quantity structures".
Information on the quantity structure of SIMATIC Route Control can be found in the manual
SIMATIC Route Control in the section "Appendix > Quantity structures".
21
Data volumes
4.2 Quantity structures for automation systems of PCS 7
4.2
22
Data volumes
4.2 Quantity structures for automation systems of PCS 7
Quantity frameworks (SIMATIC PCS 7 Advanced Process Library)
The following table shows typical mixed quantity frameworks for SIMATIC PCS 7
automation systems based on the SIMATIC PCS 7 Advanced Process Library.
AS
AS
AS
AS
AS
AS
412H
414-3IE
414H
416-3IE
416H
417H
V6.0
V6.0
V6.0
V6.0
V6.0
V6.0
10
100
100
400
400
600
20
250
250
800
800
1000
PID controllers
50
50
150
150
200
Motors
75
75
200
200
400
Valves
75
75
200
200
400
SFC
15
15
100
100
200
Steps
150
150
1000
1000
2000
Dosing
25
25
50
30
350
300
1200
1200
1800
10
100
110
400
400
650
15
175
150
600
600
900
75
50
200
200
350
30
350
350
1200
1200
2000
AS
AS
AS
AS
AS
AS
414-3
416-2
416-3
417-4
RTX
mEC
V5.3
V5.3
V5.3
V5.3
2010
2010
50
200
400
500
300
300
160
450
800
1000
600
600
PID controllers
35
75
150
180
200
200
Motors
40
100
200
350
150
150
Valves
40
100
200
350
250
250
SFC
15
40
100
200
100
100
Steps
150
400
1000
2000
800
800
Dosing
15
25
50
50
50
200
600
1200
1700
1200
1200
60
200
400
550
400
400
100
300
600
800
600
600
30
100
200
250
200
200
200
600
1200
1800
1200
1200
23
Data volumes
4.2 Quantity structures for automation systems of PCS 7
24
AS
AS
AS
AS
AS
AS
412H
414-3IE
414H
416-3IE
416H
417H
V6.0
V6.0
V6.0
V6.0
V6.0
V6.0
10
50
150
250
500
700
15
150
300
600
1000
1200
PID controllers
50
50
200
200
300
Motors
10
75
100
300
400
450
Valves
10
75
100
300
400
450
SFC
20
20
120
150
200
Steps
200
200
1200
1500
2000
Dosing
30
35
50
50
300
300
1500
2000
2000
25
150
150
700
1000
1000
20
100
100
600
800
800
10
50
50
220
400
400
AS
AS
AS
AS
AS
AS
414-3
416-2
416-3
417-4
RTX
mEC
V5.3
V5.3
V5.3
V5.3
2010
2010
35
125
200
700
250
600
110
350
450
1200
600
200
PID controllers
35
110
150
300
200
300
Motors
50
125
250
450
300
300
Valves
50
125
250
450
300
120
SFC
15
40
100
200
120
1200
Steps
150
400
1000
2000
1200
30
Dosing
15
25
45
30
1500
220
800
1200
2000
1500
1500
110
300
500
1000
700
700
80
250
400
800
600
600
40
110
180
400
220
220
Data volumes
4.3 Quantity structures for the operator station
4.3
Value
12
64
32
64
1 up to 16 (adjustable)
10
<2s
5 000 PO
per OS server
8 500 PO
150 000
approximately 3 000
per OS server
approximately 5 000
approximately 60 000
approximately 1 000/s
Long-term archiving
Archiving OS data (process values and messages) with StoragePlus
1. Archive values of a server
1. approximately 1000/s
1. approximately 1000/s
2. approximately 10 000/s
1)
2. approximately 1600/s
25
Data volumes
4.3 Quantity structures for the operator station
OS quantity structure (per multiproject) with use of the Parallel Redundancy Protocol (PRP) on the
redundant terminal bus
The following should be noted for the use of the Parallel Redundancy Protocol (PRP) on the
redundant terminal bus:
Max. number of OS servers/server pairs: 8
Max. number of OS clients in multi-client operation (per multi-station system):12
Max. number of process objects/process tags per OS server: 2000 PO
Max. number of process objects/process tags per multi-station system: 16000 PO
Long term archive tags: 17000
Message traffic: maximum of 2 messages per second and OS server
26
Index
Purpose of this documentation, 5
B
BATCH
Licensing single-station system, 13
Server/client licensing, 18
Quantity structure, 21
Automation systems, 22
BATCH, 21
Operating station, 25
Route Control, 21
Documentation
Purpose, 5
Validity, 5
E
Engineering station
Licensing, 11
S
L
License key
Selecting, 7
Software, 11, 13, 15, 18, 19
Licensing, 7
M
Maintenance Station
Licensing server, 15
Licensing single-station system, 13
Software
BATCH, 18
Engineering station, 11
License key, 11, 13, 15, 18, 19
Maintenance Station, 15
OS, 15
Route Control, 19
Single-station system, 13
V
Validity of the documentation, 5
O
OpenPCS 7, 15
Operator Station
Client, 15
Server, 15
Single-station system, 15
P
PDM, 13
PO, (See process object)
Process object
Counting, 7
Licensing, 7
27