Product data sheet

Characteristics

30670

circuit breaker Compact NS160H - TMD - 160


A - 3 poles 3d

Mar 24, 2015

Device short name

Compact NS160H

Circuit breaker application

Distribution

Poles description

3P

Protected poles description

3t

Network type

AC
DC

Network frequency

50/60 Hz

[In] rated current

150 A ( 65 C )
160 A ( 40 C )

[Ui] rated insulation


voltage

750 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse


withstand voltage

8 kV conforming to IEC 60947-2

[Ue] rated operational


voltage

690 V AC 50/60 Hz conforming to IEC 60947-2


750 V DC conforming to IEC 60947-2

Circuit breaker rating


code

Breaking capacity

Icu 100 kA at 220/240 V AC 50/60 Hz conforming to


IEC 60947-2
Icu 70 kA at 380/415 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC
60947-2
Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC
60947-2
Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC
60947-2
Icu 10 kA at 660/690 V AC 50/60 Hz conforming to
IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
65 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA at 600 V AC 50/60 Hz conforming to UL 508
100 kA at 240 V AC 50/60 Hz conforming to NEMA
AB1 HIC
65 kA at 480 V AC 50/60 Hz conforming to NEMA
AB1 HIC
35 kA at 600 V AC 50/60 Hz conforming to NEMA
AB1 HIC

[Ics] rated service


breaking capacity

Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC


60947-2
Ics 35 kA 525 V AC 50/60 Hz conforming to IEC
60947-2
Ics 50 kA 500 V AC 50/60 Hz conforming to IEC
60947-2
Ics 65 kA 440 V AC 50/60 Hz conforming to IEC
60947-2
Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC
60947-2
Ics 100 kA 220/240 V AC 50/60 Hz conforming to
IEC 60947-2

Suitability for isolation

Yes conforming to IEC 60947-2

Utilisation category

Category A

Trip unit name

TM-D

Trip unit technology

Thermal-magnetic

Trip unit rating

160 A ( 40 C )

Protection type

Overload protection (thermal)


Short-circuit protection (magnetic)

Pollution degree

3 conforming to IEC 60947


1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Main

Complementary
Control type

Toggle

Mounting mode

Fixed

Mounting support

Backplate

Upside connection

Front

Downside connection

Front

Mechanical durability

40000 cycles

Electrical durability

40000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2


20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2

Connection pitch

35 mm

Local signalling

Positive contact indication

Long time pick-up adjstment type Ir

Adjustable

Long time pick-up adjustment range

0.8...1 x In

Instantaneous pick-up adjustment type Ii

Fixed

Instantaneous pick-up adjustment range

1250 A

Height

161 mm

Width

105 mm

Depth

86 mm

Environment
Standards

IEC 60947-2

Product certifications

ASEFA
ASTA
KEMA
LCIE

IP degree of protection

IP40 conforming to IEC 60529

IK degree of protection

IK07 conforming to EN 50102

Ambient air temperature for operation

-25...70 C

Ambient air temperature for storage

-50...85 C

RoHS EUR conformity date