This document summarizes the design of a micropile with a diameter of 1000 mm. It includes calculations of the micropile's geotechnical capacity based on SPT boring logs, as well as structural capacity calculations for two micropile designs - one using an API pipe and the other using rebar reinforcement. The geotechnical capacity is determined to be 8297.5 kN. The structural capacities are 5811.8 kN for the API pipe design and 8966.8 kN for the rebar reinforced design, both exceeding the required working load of 8000 kN. Details of the micropile designs and materials are also provided.

Uploaded by

sanggytha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
239 views

Pile Calculation Using SPT

This document summarizes the design of a micropile with a diameter of 1000 mm. It includes calculations of the micropile's geotechnical capacity based on SPT boring logs, as well as structural capacity calculations for two micropile designs - one using an API pipe and the other using rebar reinforcement. The geotechnical capacity is determined to be 8297.5 kN. The structural capacities are 5811.8 kN for the API pipe design and 8966.8 kN for the rebar reinforced design, both exceeding the required working load of 8000 kN. Details of the micropile designs and materials are also provided.

Uploaded by

sanggytha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

Design of Micropile

GEOPROFOUND ENGINEERING SDN BHD

Pile Geotechnical Design using SPT Values

Site:
1000 mm

Skin Area per

3.142

Base Area, Ab =

Factor of Safety (FoS) =

Depth
Interval (m)
1
2
3
4
5
6
7
8
9
10
11
12
13.5
15
16.5
18
19.5
21
23
24

Avg SPT
Value, N
11
11
2
2
2
13
26
21
21
1
12
5
6
6
1
3
1
2
2
2

0.785

m2

2.000

Unit
End Bear at
Pile Allowable
End Bear at Pile Ultimate
Skin
Skin
Cumulative depth,
Capacity, Qult = Capacity, Qall =
Fric, fs Fric, Fs Skin Fric, Fs qb=min(400N/3 depth, Qb
, 10000)
= 2N
(kN)
(kN)
Qult/FoS (kN)
(kN)
Fs+Qb (kN)
(kN/m2)
(kN/m2)
22
22
4
4
4
26
52
42
42
2
24
10
12
12
2
6
2
4
4
2464.8

69.1
69.1
12.6
12.6
12.6
81.7
163.4
131.9
131.9
6.3
75.4
31.4
56.5
56.5
9.4
28.3
9.4
17.0
22.6
7743.2

Specified Working Load =

69.1
138.2
150.8
163.4
175.9
257.6
421.0
552.9
684.9
691.2
766.5
798.0
854.5
911.1
920.5
948.8
958.2
975.2
997.8
8741.0

1466.7
1466.7
266.7
266.7
266.7
1733.3
3466.7
2800.0
2800.0
133.3
1600.0
666.7
800.0
800.0
133.3
400.0
133.3
240.0
240.0
10000.0

8000 kN

1151.9
1151.9
209.4
209.4
209.4
1361.4
2722.7
2199.1
2199.1
104.7
1256.6
523.6
628.3
628.3
104.7
314.2
104.7
188.5
188.5
7854.0

1221.0
1290.1
360.2
372.8
385.4
1619.0
3143.7
2752.0
2884.0
795.9
2023.2
1321.6
1482.8
1539.4
1025.2
1262.9
1062.9
1163.6
1186.3
16595.0

Depth required =

Pile Capacity (kN)


0

610.5
645.1
180.1
186.4
192.7
809.5
1571.8
1376.0
1442.0
397.9
1011.6
660.8
741.4
769.7
512.6
631.5
531.5
581.8
593.1
8297.5

13

(Based on given BH/MKT Report & above FoS)

1000

2000

3000

4000

5000

Depth (m)

Round Pile =

10

15

20

m
25

03/23/2015

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Design of Micropile

Micropile Structural Capacity Calculation


Pile Diameter, =
Grade, fcu

35

1000 mm
cement grout (w/c ratio = 0.45)

Use API Pipe,

88.9 mm

fy =

6.45 mm thk

500 N/mm2 (min)

Area of Steel & Concrete


As (provided) = 2rt
As = 1670.707 mm2
Ac = *d2/4
Ac =

785500 mm2

Ultimate Axial Load,


fu = 0.4fcu*Ac + 0.75fy*As
fu =

11623515 N

fu = 11623.51506 kN
Taking Factor of Safety (FoS) =
fall = fu/FoS

fall =
5811.8 kN
Based on the structural capacity above, the micropile is able to take the given working load
of
5811.8 kN
Micropile Details
Micropile, Dia

1000 mm
API Pipe inside
88.9
6.45 mm thk

Clear spacing/Cover =

455.6

mm

03/23/2015

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Design of Micropile

Cement grout, G
W/C Ratio 0.45 min

35

03/23/2015

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Design of Micropile

Micropile Structural Capacity Calculation


Pile Diameter, =
Grade, fcu

35

1000 mm
cement grout (w/c ratio = 0.45)

Use Rebar,

32 mm

fy =

25 Nos

460 N/mm2 (min)

Area of Steel & Concrete


As (provided) = rbars2
As = 20106.19 mm2
Ac = *d2/4
Ac =

785500 mm2

Ultimate Axial Load,


fu = 0.4fcu*Ac + 0.75fy*As
fu =

17933637 N

fu = 17933.63658 kN
Taking Factor of Safety (FoS) =
fall = fu/FoS

fall =
8966.8 kN
Based on the structural capacity above, the micropile is able to take the given working load
of
8966.8 kN
Micropile Details
Micropile, Dia

1000 mm
R6 Spiral Link

Rebar

4Y12

03/23/2015

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Design of Micropile

Cement grout, G
W/C Ratio 0.45 min

35