LGP4247 11SPL
LGP4247 11SPL
LGP4247 11SPL
Rev 1.3
Specification
Rev 1.3
1. INTRODUCTION
1.1 Scope
This approval is the description related to every electrical and structural specifications
and reliability For Power Supply Unit used on 4247 inch LGE LED TV.
1.2 Customers product related items
Product : Power Supply Unit
Part code : EAY62171601
AC 100V to AC 240V
AC 90V to AC 264V
Input Current
Nominal Frequency
50 / 60 Hz
47 Hz to 63 Hz
Phase
Single
Leakage Current
Surge Immunity
Hold-up Time
Lightning Surge
Inrush Current
Rev 1.3
Output
Voltage
Variable range
[V]
Rated Current
(Min, Max)
[Amean]
Voltage
Regulation
[V]
Ripple
Voltage
[mVp_p]
5%
250 mVp_p
0.09W Under(6mA)
3.5V
(STBY)
3.325V ~ 3.675V
12V
11.4V ~ 12.6V
3 (0.3~3
5%
350 mVp_p
24V
22.8V ~ 25.2V
4.1 (0.1~4.1)
5%
500 mVp_p
* On Condition : In a moment of Power_ON Signal activated, the current of 3.5V output should be
limited within 40mA(Max) at LCD TV condition for stability.
Do not turn Power_ON Signal on at the load condition of 3.5V output, more than 40mA.
* Total regulation for each output circuit includes the results of input voltage variation,
load variation, warm-up drift and temperature change.
* The following instruments shall be used for measuring ripple noise.
1. Probe having impedance ratio of 1:1.
2. Oscilloscope having frequency characteristic of 100MHz or more.
- Test Point : power output each pin
Add Electrolytic Capacitor 47 + 0.1
Load
Oscilloscope
Measurement point
Ripple and noise are measured at the end of output cable which are added a 0.1uF ceramic
capacitor and 47uF electrolytic capacitor. ( connected parallel )
Rev 1.3
3.5V (STBY)
Load [A]
12V
0.006
Wattage [W]
24V
Dont Care (Power-Off)
-10 to 40
(60:No Hardware Failure, TV SET Condition)
30 to 85 %
-25 to 85 deg.
5 to 90 %
MTBF
(Mean Time Between Failure)
50,000 hour
Cooling Condition
Shock
Natural Air
98
Shock test consists of pivoting the power supply, from
one edge of its bottom side, on a flat surface
(such as wood having thickness of 10mm or more) and
allowing the opposite edge to fall from a height of 50mm
to this surface.
The test is performed three times on each edge of the
bottom side of the power supply
Safety
Dielectric
Strength Voltage
Insulation
Resistance
Rev 1.3
2.6 Interface
Appellation
Explanation
POWER ON
Signal Direction
Action
Hi : Vcc ON
Low : Vcc OFF
Input
Safety
2.8 Construction
Weight
Unit Size
Over Current
Short Circuit
Trip point
Output Circuit
Notes
Min
Max
STBY 3.5V
3.0A
6.0A
Auto Re-start
12V
8.0A
28.4A
Latch
24V
5.0A
14.2A
Latch
STBY 3.5V
Auto Re-start
12V
Latch
24V
Latch
10
Rev 1.3
11
Rev 1.3
P202
Type : SMAW200-H24S2
Maker : YEON-HO
Type : 20010WR-H14B/C
Maker : YEON-HO
Pin No.
Signal
Pin No.
Signal
Pin No.
Signal
POWER-ON
24V
24V
24V
24V
24V
GND
GND
24V
GND
GND
24V
3.5V
10
3.5V
24V
11
3.5V
12
3.5V
GND
13
GND
14
GND
GND
15
GND
16
N.C
GND
17
12V
18
INV ON/OFF
GND
19
12V
20
A-DIM
10
GND
21
12V
22
P-DIM
11
ERROR
23
N.C
24
ERROR
12
INV ON/OFF
13
A-DIM
14
P-DIM
SK100
Type : 90011WR-H03D
Maker : YEON-HO
Pin No.
Signal
LIVE
F.G
NEUTRAL
12
Rev 1.3
4.5mm
240
4.5mm
4.5mm
290
4.5mm
9.0mm
(Tolerance 0.5mm)
PCB : 1.6mm
SMD Holder : 2.5mm (Tolerance 0.4mm)
Lead cutting : 2.3mm
(Except T101, L601 Body : 2.3mm+0.5mm , GH : 2.5mm +0.5mm)
13
Rev 1.3
14
Rev 1.3
No.
Test Item
Test method
Intermittent
Operation stability
Test
Low temperature
operation
Low temperature
Storage test Leave
At low temperature
Temperature
30 minutes
25
30 minutes
25 -> -20
60 minutes
30 minutes
-20 -> 25
30 minutes
25
30 minutes
25 -> 70
60 minutes
30 minutes
70 -> 25
15
Rev 1.3
No.
Test Item
Test method
Appearance
Vibration
Shock
On the oak more than 10mm thickness with the flat face, raise
the one side for 50mm, and it carries out each side free fail for
three sides.
There shall be no damage to appearance and construction.
16