#2 Plumbing Definitions Study This Set Online at
#2 Plumbing Definitions Study This Set Online at
#2 Plumbing Definitions Study This Set Online at
2-2 A horizontal waste and vent pipe which is sized to provide free
circulation of air above the ow line of the drain pipe is dened by
the code as a: (A) Combine waste & Vent system (B) continuous we
t vent system (C) nonsolvent waste & vent System (D) ventilating p
ip[ing system
(A) Combine waste & Vent system. is a special horizontal wet venti
ng system using a common pipe to receive the waste from one or
more sinks , oor drains, etc.
2-3 A "Dead end" as dened by the codse is. (A) a water main that
makes a 90 degree turn and is capped. (B) a gas linhe that continu
es from horizontal to vertical for future use. (C) a branch extending
a minimum of 2 ft beyond a building drain & Plugged (D) a utility all
ey used for piping installation that comes to an end
2-7 The Code denes water that is safe for drinking purposes as : (
A) soft water (B) potable water (C) hard water (D) clear water
A) Avoid Misunderstanding
#2 Plumbing Denitions
Study this set online at: http://www.cram.com/ashcards/2-plumbing-denitions-958
428
(A) Leader
(C) Stack Vent (dry Portion) is the extension of a waste stack - abov
e the highest horizontal drain connected to a stack
#2 Plumbing Denitions
Study this set online at: http://www.cram.com/ashcards/2-plumbing-denitions-958
428
2-17 The criteria for testing the plumbing system were established
by code. The word CITERIA, as used in the sentence Means: (A) Sta
ndards (B) Costs (C) eorts (D) usage
(A) Standards
(D) Objective
2-19 Any trap which has interior particans is not recignized by the c
ode: (A) declared (B) approved (C) perceived (D) demanded
(B) approved
2-20 Traps for oor drains must be provided with a means of acces
s for cleaning. The word ACCESS means (A) permission (B) a means
of taking (C)Flexiblity (D) a means of approach
(A) Unchanging
(C) rarely
2-24 The following plumbing terms , the one most correctly drned
, according to the code is: (A)"soil pipe" shall mean any pipe manuf
actured of pvc schedule 40 which conveys waste to building drain. (
B) 'Sub-Drain" shall mean the portion of a drainage system installed
below the rst oor level. (C) "INdirect waste PIPE" shall mean wast
e pipe which fails to connect directly to the building drainage syste
m (D)"STAcK" shall mean any line, soil waste or vent piping
(C) "INdirect waste PIPE" shall mean waste pipe which fails to conne
ct directly to the building drainage system
#2 Plumbing Denitions
Study this set online at: http://www.cram.com/ashcards/2-plumbing-denitions-958
428
2-25 Of the following terms, the one most correctly dened , accor
ding to code , is: (A) "developed lenght" shall mean its length along
the centerline of the pipe and ttings (B) "Continuous Waste" shall
mean a drain connecting several xtures to one drain pipe. (C) "Lea
der" shall mean any pipe conveying storm water to an approved di
sposal area (D) "Branch" shall mean any part of the piping system i
ncluding ttings and risers
(A) "developed lenght" shall mean its length along the centerline of
the pipe and ttings
2-28 The code denes a sewer which receives storm water , sewag
e and liquid waste as a: (A) private sewer (B) combined sewer (C) p
ublic sewer (D) special sewer
Ans (c) Back siphonage is the owing of watger back from a xture
(water heater) into a water supply pipe.