The Heat Balance and
Efficiency of Steam Boilers
By : Debanjan Basak
The efficient utilization of fuel in steam boilers
is primarily determined by the following three
factors :
Complete combustion of the fuel in the
furnace
Deep cooling of the combustion products
during their passage through heating
surfaces.
Minimization of heat losses to the
environment.
2
Heat absorbed by working
fluid in boiler :
Heat content of superheated steam
from boiler
Heat content of reheated steam from
boiler
Heat content of boiler blow- down
water
HEAT BALANCE IN STEAM GENERATOR
INPUT
Heat in Fuel
Heat in atomising steam
Sensible heat in fuel
Pulveriser or crusher power
Boiler Circulating pump power
Primary air fan power
Recirculating gas fan power
Heat supplied by moisture in entering air
Heat in Final superheater steam
Heat in desuperheater water
Heat in feedwater
Boundary envelope
Heat in blowdown water
Heat in reheat steam out
OUTPUT
Heat in desuperheater water
Heat in reheat steam in
Unburnt carbon in ash
Heat in dry gas
Moisture in fuel
Moisture from burning hydrogen
Moisture in air
LOSSES Heat in atomising steam
Unburnt gases
Radiation and convection
Sensible heat in slag
Heat in mill rejects
Sootblowing
Reference : PTC ; 4.1
Efficiency
Input = Heat input
Output = Input losses
Efficiency = Input
Output
The Heat balance Equation
The distribution of the heat supplied to
the boiler as useful heat and lost heat is
the basis for compiling the heat
balance of a steam boiler
The Heat Balance Equation
Q = Q1 + (Q2 +Q3 + Q4 +Q5 + Q6) where :
Q= available heat of burnt fuel
Q1= heat absorbed by working fluid
Q2 to Q6 = heat losses
Dividing both sides by Q and expressing as a %age we get :
100 = q1 +(q2 +q3+q4+q5+q6)
7
Methods of determining Boiler
Gross efficiency
Direct method
Inverse balance method
The direct method
Uses the heat balance equation
Measures Q and Q1
Method is insufficiently inaccurate
Accurate measurements of certain
parameters like mass flow rate of steam
and fuel,heating value of fuel etc is not
possible
Not a preferred method
9
The inverse balance method
Uses the equation
Efficiency = 100 (q2 +q3+q4+q5+q6)
Determines the sum of heat losses
Is more accurate method since the sum of
the heat losses roughly constitutes 10% of
Q1.
All the items can be reliably measured
Is the SOLE method used for determining
efficiency
10
Heat Losses in Steam Boilers
Item
Symbol
Waste Gases
q1
4-7
Incomplete
combustion
q2
0 0.5
Unburnt Carbon
q3
0.5 - 5
Cooling through
lining
q4
0.2 - 1
Pysical heat of
removed slag
q5
0-3
Sum of heat losses
% as relative loss of Q
6 - 12
11
Chart depicting heat losses
Waste gases
Incomplete combstion
Unburnt carbon
Cooling through lining
Physical heat of
removed slag
12
Analysis of Heat losses in
Steam Boilers
13
Dry Flue gas loss
Is the largest component of heat loss
It depends on the absolute difference
between the enthalpy of waste gases
and the enthalpy of cold air supplied.
The enthalpy of waste gases depends
on the exit temperature of waste gases
and its volume.
14
Dry Flue gas loss
It is the heat lost to the atmosphere by
dry component of flue gas
Also referred as stack loss
Carbon and sulphur in coal burn to form
the dry component of flue gas
Carbon can burn to form either CO or
CO2
15
Components of Dry Flue gas
Carbon- Dioxide
Carbon Monoxide
Residual oxygen
Nitrogen
Sulphur Dioxide can be neglected for
Indian coals
16
Seigert Formula for estimation of Dry Flue
gas loss
% loss = K ( T t )
% CO2
K is a constant whose value are taken as :
For anthracite : 0.68
For Bituminous coal : 0.63
For coke : 0.70
17
Wet flue gas loss
Wet products of combustion are obtained
from the following components in fuel :
Moisture
Hydrogen Burns to form water vapour
1 Kg of hydrogen burn to form 9 Kg of
moisture
The heat lost with the mass of the water
vapour along with flue gas to the atmosphere
is known as wet flue gas loss
18
Sensible Heat of water vapour
This is the amount of sensible heat
absorbed by moisture in coal
Is calculated by :
( Wet FG loss (GCV NCV)) KJ/Kg fuel
19
Moisture in combustion air
This is the amount of heat absorbed by
the moisture present in cold air
However this loss is very small and is
normally not calculated
20
Heat loss with waste gases
By reducing the temperature of waste gases by 22
degree cent it is possible to increase boiler efficiency
by 1%.
The exit temperature of waste gases depends on
feed water temperature at economizer inlet and and
cold air temperature at air heater inlet.
The exit temperature depends on the moisture
content of fuel used.A higher moisture content
results in increase of heat loss for the same heating
surface due to higher volume of combustion.
21
Heat loss with waste gases
A cost economic approach is taken for
determining the design optimal flue gas exit
temperature.
One of the main considerations in limiting the
FGET is the low temperature acid corrosion in
air preheaters.The waste gas temperature is
generally kept within 140- 160 deg cent to
prevent acid condensation.
22
Reasons for high FGET
Improper soot blowing
Deposition on furnace wall tubes
Low feed water inlet temperature
Low temperature at air heater inlet
High moisture content of fuel
High excess air ratio
High air infiltration
23
Clean
Tube
Soot
Scale
Both side
deposits
1200C
Limiting Metal
Temp of 450C
300C
200M
Kcal/hr/m2
150M
155M
Kcal/hr/m2
Kcal/hr/m2
120M
Kcal/hr/m2
Typical Heat transfer and temperature drop across furnace tube
Heat loss with unburnt carbon
In the combustion of solid fuels, unburnt coke
particles are carried off from the combustion
chamber by flue gases.
During the short time they are present in the high
temperature zone of the flame, these particles evolve
volatile mater but remain partially unburnt.
Under normal operating conditions, these unburnt
carbon loss may range from 0.5% to 5%
More the VM of fuel less is the heat loss.
25
Heat loss with unburnt carbon
This loss can be divided into :
Carry over loss
Loss with slag or bottom ash
The carry over loss is much predominant over
the loss with slag.
The carry over loss is determined by the
carbon content in Fly ash samples collected
from ESP hoppers.
The slag loss is determined by the carbon
content in bottom ash samples.
26
Heat loss with unburnt carbon
The carry over loss depends on :
Excess air ratio
The VM of coal used
The slag loss depends on :
Improper fineness of pulverized fuel
from mills
27
Heat loss by Incomplete
combustion
The products of combustion contain
gaseous combustible substances such
as CO,H2 or CH4.
Their afterburning beyond the boiler
furnace is practically impossible since
the temperature of gases and
concentrations of combustible
components and oxygen are too low.
28
Heat loss by Incomplete
combustion
The heat that may be produced by afterburning
these components constitutes the heat loss due
to incomplete combustion.
This item of heat loss is mainly determined by
the concentration of CO and to a lesser extent
H2 in flue gas.
However analysis for incomplete combustion
should always be done for all components of
flue gas since even a slight quantity of CH4 may
have a noticeable effect .
29
Heat loss by Incomplete
combustion
Heat loss due to incomplete combustion
substantially depends on excess air ratio and
boiler load conditions.
Theoretically, thorough intermixing of fuel
and oxygen ensures that this heat loss may
take place only for K<1.
Under real conditions, incomplete combustion
cannot take place at critical excess air ratio
which is usually1.02 1.03.
30
Heat loss by Incomplete
combustion
With reduced load conditions, the exit
rate of fuel and air through the burners
decreases causing improper mixing
which results in increase in heat loss.
Also the temperature of the combustion
zone decreases with reduced load
causing an increase in incomplete
combustion
31
Unaccounted losses
Radiation loss
Loss due to unburnt volatile
hydrocarbons
Loss due to combination of carbon and
water-vapour
Mill rejection
Physical heat carried by bottom and flyash
32
Heat Loss by Radiation
Since the temperature of the boiler linings
and casings are higher than the surroundings,
they give up heat to the environment.
Higher is the temperature of the linings and
casings higher is this heat loss.
In general the boiler casings should be
insulated in such a way that the average
temperature of the casings is not more than
55 degree cent.
33
Typical summary of Radiation and
Unaccounted losses
Boiler
Rating
020
Approximate Range in %
0.6 1.7
050
0.38 1.2
060
0.35 1.15
100
0.3 1.0
200
0.25 0.93
500
0.2 0.88
34
Heat Loss by Cooling
In rough calculations, the heat flux from the
boiler surfaces to the surroundings is taken at
an average level of 200 300 W/m2
With increasing boiler power, the absolute
and relative heat loss q5% becomes lower as
the total heat release and the volume of
combustion products increase more quickly
than the area of exposed boiler surfaces.
35
Heat loss with physical heat of
slag
The slag removed from the bottom of a boiler
furnace has rather high temperature and
possesses a significant amount of heat.
This heat is transferred to cooling water in
the slag bath and is lost irreversibly
In dry bottom furnaces the temperature of
slag is 600- 700 deg cent.
In slagging bottom furnaces the temperature
of flowing slag is 1400 1600 degree cent.
36
Heat loss with physical heat of
slag depends on
Total ash content of fuel
Fraction of ash removed as slag from
furnace
Enthalpy of slag
Method of removal of slag from
furnace.
37
Theoretical Air
It is the quantity of air required by a
fuel which will provide just sufficient
oxygen for complete oxidation of the
combustible components present in the
fuel
It is also known as the stoichometric air
requirement
38
Quantity of theoretical air
The theoretical air is calculated from the
Ultimate analysis of fuel by the formula :
4.31 x
8 C
3
8(H- O )
8
Kg/Kg of fuel
The value within the bracket denotes the quantity of
oxygen reqd.
The factor 4.31 gives the amount of air required to supply
this oxygen
39
Excess Air
The actual amount of air required for complete
burning of a fuel is always more than the theoretical
air.
This additional quantity of air required over the
theoretical air is known as excess air
Present designs allow for 20% excess air for coal
fired boilers
THE SUM OF THEORETICAL AIR AND EXCESS AIR IS
THE TOTAL AIR REQUIOREMENT FOR A BOILER
40
Reasons for excess air
To overcome the uncertainties in the
fuel-air mixing process
To ensure intimate mixing of fuel and
oxygen at point of injection
To account for errors in ultimate
analysis of fuel
41
Quantity of excess air
Excess air =
(O2 % X100)/ (21 O2%)
OR
(CO2 %(max) x 100)/CO2% - 100
42
Conclusion
The quantity of excess air adversely
affects boiler efficiency
The quantity of excess air needs to be
optimized for achieving maximum
efficiency of boiler
43
Monitoring of excess air
By residual carbon dioxide in flue gas
By residual oxygen in flue gas
By residual carbon- monoxide in
flue gas
44
Optimisation of Total Air supply
12
11
Total Loss
10
9
Optimum Total air
Boiler Loss %
Dry Gas loss
7
6
5
4
3
Aux. Power
Unburnt Gas
2
1
Comb. In ash
14
15
16
17
Carbon- Dioxide %
45
Optimisation of Total Air
Unburnt gas (primarily CO) is formed just a little
higher than the optimum CO2
Measurement of CO is a better method of
determining optimum air quantity
Oxygen measurement in flue gas can be misleading
due to air ingress
Modern combustion control utilizes CO measurement
in addition to Oxygen measurement
46
Graph Depicting variation of Oxygen with Carbon Monoxide in Flue gas
Saturation
700
ppm vol CO at ID fan discharge
600
Air Deficient
Air Rich
500
400
Ideal Operating Point
300
200
100
6
% Oxygen In Flue gas
2
8 At ID Discharge
5 At AH Inlet
47
Effect of mill operation on CO breakpoint for a 500 MW PF boiler
6 Mills equally loaded
6 Mills unequally loaded
500
ppm vol CO at ID fan discharge
5 Mills equally loaded
400
300
200
100
3
4
% Oxygen In Flue gas at Air Heater Inlet
48
Increasing
Trend of Boiler Gases with variations in excess air
CO2 %
CO2 %
O2 %
Decreasing
SO2 ppm
-20
-10
0
Excess Air %age
10
20
49
50