Avcs User Guide Danelec v1.0
Avcs User Guide Danelec v1.0
Danelec ECDIS
Version 1.20 1.50
Version 5.0.83.546
Version 4.5.1.6
TABLE OF CONTENTS
Introduction .................................................................................... 4
Introduction
This guide should be used in conjunction with the AVCS User Guide, as well as the
ECDIS Operators Manual or other documentation as supplied by the equipment
manufacturer.
The actual instructions and screenshots in this guide are based on the version of the
Danelec ECDIS installed in the UKHO as detailed on the front cover. There may be
minor differences between certain models and these will be highlighted in this guide
where known (i.e. screen layouts may vary).
Data Management
All electronic chart licensing and data management operations are carried out through the
DATA menu option.
Within the ECDIS move the cursor over the Menu icon in the bottom right hand corner of
the screen.
This provides the user with a further eight menu options. To manage the ENC Data select
the DATA option.
The User Permit is a 28 character alphanumeric string that is unique to each ECDIS
installation or group of ECDIS, e.g. multiple bridge installations. The User Permit should
have been supplied at the time of delivery and must be used when ordering an AVCS
licence and ENC permits.
If the User Permit is mislaid it can be retrieved from within the Danelec ECDIS in the form
of a text file as it is not possible to display the User Permit on the screen.
Main MENU: DATA Import S57 tab
1. From main Menu select the DATA option.
2. Select the Import S57 tab.
3. Select the Copy user permit.
2.
3.
1.
4.
4.
4.
New AVCS customers who had previously subscribed to other ENC services are strongly
recommended to remove (purge) all ENC Permits and ENCs from the system before
installing AVCS. For more information please refer to the pre-installation checks within the
generic AVCS manual.
When there are installed charts in the ECDIS the user can choose to remove (delete) all of
the installed ENCs from the system database (SENC). This is achieved by removing the
required Database.
Main MENU: DATA Databases Unregister database
1. From main Menu select the DATA option.
2. Select the Databases tab.
2.
1.
3.
3.
4. Select Yes to confirm deletion of the database.
3.
This process will remove all of the ENC data relating to that particular database.
The Danelec ECDIS does not allow the deletion of individual ENCs.
If the user has previously subscribed to another ENC service it is advised to remove these
ENC permits from the ECDIS system before use.
Main MENU: DATA Import S57 tab Apply S63 cell permit
1. From main Menu select the DATA option.
2. Select the Import S57 tab.
3. Select Apply S63 cell permits
2.
3.
1.
4. In the Apply S63 cell permits window select Installed cell permits
4.
10
5.
5.
6. Select Yes to confirm deletion
6.
11
The Admiralty Vector Chart Service currently uses the PRIMAR.CRT, issued by Primar
Stavanger, to authenticate its AVCS ENCs.
Before installing AVCS ENCs, the user must check that the correct Public Key is installed
on the system. This can be viewed in the Danelec ECDIS by following the steps below.
If the PRIMAR Public Key is not present on the system then it will have to be installed
before AVCS ENCs can be loaded.
The PRIMAR public key is included on all AVCS Base and Update CDs.
Main MENU : DATA Import S57 Apply SA Certificate
1. Select DATA from the main Menu.
2. Select the Import S57 tab.
3. Select Apply SA Certificate.
3.
3.
1.
12
4.
5. This will display information about the currently installed Public Key. Select Close to
complete the process.
5.
13
2.
3.
1.
4. On the Apply SA Certificate screen browse to the location of the PRIMAR.CRT.
Select the PRIMAR.CRT and select Apply certificate.
4.
4.
14
5.
15
To install ENC Permits into the Danelec ECDIS please follow the directions below.
Cha Main MENU: DATA Import S57 tab Apply S63 cell permits
1. From main Menu select the DATA option.
2. Select the Import S57 tab.
3. Select Apply S63 cell permits
2.
3.
1.
4. Browse to the location of the permit.txt and select the file
5. Select Apply cell permit
4.
4.
5.
16
6.
17
There are currently 9 AVCS Base CDs. This number will grow as more ENCs become
available for distribution within AVCS. It is unlikely that users will need to install all of the
CDs in order to load all licensed ENCs. Reference to the Schedule A can avoid the
unnecessary loading of some CDs and save the user time.
The process described here should be used in almost all circumstances as it will
automatically select data to be loaded according to the permit file installed by the user.
Main MENU: DATA Import S57
1. From main Menu select the DATA option.
2. Select the Import S57 tab.
2.
1.
3. Insert AVCS Base CD and select Find database
4. Enter a name in the Database Name section.
4.
3.
18
7.
5.
6.
Note: It is advised that Turn off the errors report is ticked to reduce the manual
intervention.
SSE 10 Permits not available for this data server will be encountered for charts that
they user is not licensed to view.
8. Select OK to complete the process.
8.
9. Any errors encountered during installation will be reported in the Processing section
and can aid in resolving loading issues.
9.
19
11
.
10
.
Repeat the above steps for all required AVCS Base CDs.
20
Note: Base CDs are re-issued about every 6 to 8 weeks. The AVCS Update CD indicates
which Base CD must have been installed before the update disc can be applied. (see
above image)
It is important that users do not attempt to load an Update CD that is not consistent with
the Base CDs.
Main MENU: DATA Import S57
1. From main Menu select the DATA option.
2. Select the Import S57 tab.
3. Select Find databases to allow the Danelec ECDIS to scan the AVCS Update CD.
21
2.
1.
3.
4. Select the CD in the S57 source data section.
5. Select the Database Name: from the drop down menu. This must be the same as
the Base Database.
6. Make sure the Turn off the errors report is ticked.
7. Select Convert.
5.
7
6.
.
4.
6.
Note: It is advised that Turn off the errors report is ticked to reduce the manual
intervention.
SSE 10 Permits not available for this data server will be encountered for charts that
they user is not licensed to view.
8. Select OK to complete the process.
8.
22
9. Any errors encountered during installation will be reported in the Processing section
and can aid in resolving loading issues.
9.
23
10 System Checks
To check the status on of installed AVCS ENCs please follow the below instructions.
Main MENU: DATA Chart Catalogue
1. From main Menu select the DATA option.
2. Select the Chart Catalogue tab.
2.
1.
3.
4.
24
11 Troubleshooting
Many of the difficulties that could be experienced when using the Admiralty Vector Chart
Service with this system can be avoided by carefully following the instructions in this guide.
However, issues that are known to have caused confusion in the past are detailed in the
Frequently Answered Questions (FAQ) section which can be found at:
http://www.ukho.gov.uk/Support
If you encounter problems that are not solved by referring to the FAQs, you may wish to
seek Technical Support. Please see the section below for contact details.
Who should you contact?
You will receive the most effective support if you address your initial query to either the
Manufacturer of your ECDIS equipment or the Chart Agent you obtain your AVCS charts
from, but in certain circumstances you may need to contact the UKHO Customer Services.
Problem
Contact
ECDIS
Manufacturer
Admiralty
Chart Agent
UKHO
Customer Services
When reporting a chart related problem it is useful if you can provide the following
details:
- Licence Number
- Vessel Name
- ECDIS/Software Manufacturer
- Details of error message Including SSE error code
- Screen shot(s) of error
- Details of Base Discs used (date)
- Details of Update CD used (date)
- Details of Permits used (date)
- Details of Cell number(s) errors apply to
- Have there been any configuration changes to computers
- Details of User Permit(s) and PIN Number(s)
Emergency Chart Permit Generation
In certain circumstances it may be necessary for a vessel to get access to an AVCS chart
at very short notice, for instance if a route needs to be diverted due to a medical or
25
Web:
Telephone:
Facsimile:
Email:
Contact:
http://www.ukho.gov.uk/Support
Feedback
We hope this User Guide assists you in using the Admiralty Vector Chart Service with this
system. If you have any feedback on the content of this particular guide, or the online
FAQs, please forward your comments to your Admiralty Chart Agent or directly to UKHO
Customer Services.
26