Operating Instruction: Fuel Cell Monitor Pro 3.0
Operating Instruction: Fuel Cell Monitor Pro 3.0
www.h-tec.com
h-tec
Wasserstoff-Energie-Systeme GmbH
Hydrogen Energy Systems
Lindenstrasse 48a
23558 Luebeck
Germany
Phone
Fax
e-mail
website
www.h-tec.com
Contents
1
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
2
2.1
2.2
2.3
2.4
2.5
3
3.1
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.3
3.4
3.5
3.6
3.7
3.8
3.9
4
5
6
General ..........................................................................................................4
Purpose / Introduction ....................................................................................4
Product Description ........................................................................................4
Menu Languages ...........................................................................................5
System Requirements ....................................................................................5
Standard Delivery...........................................................................................5
Appropriate Use .............................................................................................5
General Safety Instructions.............................................................................6
Usage Conditions ...........................................................................................6
Liability ..........................................................................................................7
Support ..........................................................................................................7
Manufacturer .................................................................................................7
External Measuring Transformer Card and Software .......................................8
Connections ...................................................................................................8
Installation of the Drivers for the External Measuring Transformer Card ..........9
Fuel Cell Monitor Installation ........................................................................10
First Run ......................................................................................................10
Menu Items ..................................................................................................12
Measured Value Recording .......................................................................... 13
General ........................................................................................................13
Characteristic Curve Recording ....................................................................14
Automatic Characteristic Curve Recording of a Fuel Cell ..............................14
Voltage-regulated Characteristic Curve Recording of a Fuel Cell ..................15
Current-regulated Characteristic Curve Recording of a Fuel Cell ..................16
Manual Characteristic Curve Recording of a Fuel Cell...................................17
Recording of Individual Stack Voltages .........................................................19
Efficiency of a Fuel Cell ................................................................................21
Recording of Electrolyser Characteristic Curves ...........................................22
Recording of Efficiency Characteristic Curves of an Electrolyser ...................24
Saving of Measured Data .............................................................................25
Report ..........................................................................................................26
Four-terminal Sensing ..................................................................................26
Maintenance ................................................................................................27
Troubleshooting............................................................................................28
Technical Data .............................................................................................30
www.h-tec.com
General
1.0
Purpose / Introduction
The claimed climate change in combination with the increasing global energy requirements and the
declining resources of coal, oil and gas make the development of new sources of energy one of the main
tasks of the 21st century. Hydrogen technology has particular importance. Electricity can be generated
directly from hydrogen and oxygen using fuel cells. The only waste product: water. Using electricity
which can be obtained for example from solar cells, the required hydrogen can be produced directly
from water by decomposition into hydrogen and oxygen. The underlying principle is called electrolysis.
Both methods form the solar hydrogen circuit jointly.
The h-tec team wishes you fascinating experiments and interesting insights into the energy supply of
the future
h-tec
Hydrogen energy Systems
1.1
Product Description
The Fuel Cell Monitor (FCM) is a didactic product consisting of a measuring transformer card and evaluation software. It is tailored to the requirements for the measurement of h-tec products and must only
be used for this. The FCM is available in two versions: As Standard Version U104 Fuel Cell Monitor 3.0
and as extended Version U103 Fuel Cell Monitor Pro 3.0. Both versions provide you with the possibility of
measuring, storing and evaluating various measured values and characteristic curves of h-tec fuel cell
education models. The external measuring transformer card is connected to the PC using a USB cable.
The supplied software gives you the possibility to record and display the following graphs:
Voltage against current
Power over time
Power against current
Power against voltage
The measuring transformer card also provides the possibility of four conductor measurement for the
compensation of measurement errors. The measured value recording can be performed automatically,
voltage-regulated, current-regulated or manually. The efficiency of h-tec educational fuel cells can also
be measured with the FCM.
The extended Version U103 Fuel Cell Monitor Pro 3.0 can also display up to ten individual voltages of a
fuel cell stack in real-time and record and display characteristic curves and efficiency of h-tec educational electrolysers.
www.h-tec.com
1.2
Menu Languages
1.3
System Requirements
Minimum computer requirements: Pentium 200 Mhz or comparable processor (we recommend a Pentium III, a Celeron with 600 Mhz or a comparable processor). The FCM needs at least 80 MB free disc
space (for the installation of the standard drivers, however at least 580 MB is recommended). Operating
system: Windows 2000 at least Service Pack 3, XP or Vista, RAM: minimum 128 MB (recommended 256
MB), USB connection.
The screen resolution should be set to at least 1024 x 768. A spreadsheet program (such as, e.g. MS
Excel or Open Office) is also recommended for the further processing of the stored measured data.
1.4
Standard Delivery
1.5
Appropriate Use
Measurements of h-tec products in the following areas can be performed and evaluated using the external measuring transformer card of the Fuel Cell Monitor and the associated software:
Fuel cell mode
Voltage: 0 - 10 V DC
Current: 0 - 5 A
Power: 0 - 10 W
Electrolysis mode: (only for extended Version U103 Fuel Cell Monitor Pro 3.0)
Voltage: 0 - 4 V DC
Current: 0 - 3 A
Power: 0 - 10 W
The hardware and software have been exclusively developed for educational and demonstration purposes. The output measured values and graphs must be assessed qualitatively.
Any other use is not permitted.
In order to prevent dangers, strictly observe the general safety instructions for your measurements with the FCM and fuel cells.
www.h-tec.com
1.6
The device is only intended for commercial use (schools, universities, institutions, companies).
The device must only be put into operation and operated by a competent person.
ATTENTION! Not suitable for children under 12!
The operating manual must be read before operation, observed and kept ready to hand for reference. This also applies to the operating instructions of the fuel cells and electrolysers used.
Wear safety goggles when handling fuel cells and electrolysers.
The device is not a toy.
The device and gases must be kept and operated out of reach of small children.
Disconnect the device from all connection cables before cleaning with liquids.
Never clean measuring transformer card of Fuel Cell Monitor by using liquids!
Unless otherwise stated, connection terminals must not be connected with reverse polarity or
short-circuited.
Remove flammable gases, fumes or liquids from the vicinity of fuel cells and electrolysers. The catalytic substances contained can trigger self-ignition.
Hydrogen and oxygen can discharge from fuel cells and electrolysers. Prevent the
gases accumulating and forming potentially explosive mixtures by only using the
device in well ventilated rooms.
Fuel cells and electrolysers must only be operated in glass cabinets if sufficient ventilation of the latter under all circumstances is ensured. The operator must prove this by means of
corresponding measurements.
Remove all substances which can trigger an ignition of the hydrogen (open flames,
substances with possible electrostatic charge, catalytic substances) from the vicinity of
fuel cells and electrolysers.
Do not smoke.
Only use the gas tanks included with the equipment for the gas storage. Never connect
other gas tanks.
In the case of non-compliance with these safety instructions, h-tec Hydrogen Energy Systems
accepts no responsibility for resulting damage.
1.7
Usage Conditions
Read through the following paragraphs carefully before you use this software. If you do not agree with
the following, do not use the software and delete it from your data carriers.
You are not entitled to reverse engineer, decompile or disassemble the software product whether in
whole or in part.
www.h-tec.com
1.8
Liability
It is not possible with todays technology to rule out every error in a software application. Accordingly, the
Fuel Cell Monitor 3 program can contain errors. For this reason, the manufacturer makes no guarantee
of any kind for this software and is not liable for any kind of damage which has been caused directly or
indirectly by the software. The exception to this is gross negligence.
1.9
Support
The program has been carefully tested by h-tec in order to provide you with as reliable a product as
possible. Nevertheless, should you notice undiscovered error sources, please contact us. Please state
the version of your FCM in the case of questions or suggestions. You can display this using Help R
about FCM. Current versions of the program are available for download at any time from www.h-tec.
1.10
Manufacturer
h-tec
Wasserstoff-Energie-Systeme GmbH
Hydrogen Energy Systems
Lindenstrasse 48a
23558 Lbeck
Germany
Telefon
Telefax
e-mail
website
www.h-tec.com
3
4
6
4
3
2
Fig. 1:Measuring transformer card
2.1
Connections
1) USB connection: for connecting the measuring transformer card to the PC. The connection cable
is included in the standard delivery.
2) Fuel cell and electrolyser 4 mm connection sockets: connections for the cell to be measured (fuel
cell or electrolyser). Also suitable for 4 mm safety measuring cables. 4 mm red and black cables
are included in the standard delivery (Fuel Cell Monitor Pro 3.0).
3) Fuel cell and electrolyser 2mm connection sockets: connections for the cell to be measured (fuel
cell or electrolyser). 2mm red and black cables are included in the standard delivery.
4) Connection sockets for four-wire measurement: 2 mm connections for the compensation of measurement errors during the fuel cell and electrolyser measurement. 2 mm red and black cables
and adapter for the use of 4 mm cables are included in the standard delivery.
www.h-tec.com
5) Power supply connection: Connection of the power supply for electrolyser measurements. The
power supply is included in the standard delivery (Fuel Cell Monitor Pro 3.0).
6) Connection for stack individual voltage measurements: for connecting the individual voltage
measurement cable to a fuel cell stack for the measurement of the individual cell voltages. The
individual voltage measurement cable is included in the standard delivery
(Fuel Cell Monitor Pro 3.0).
It is recommended to setup the hardware and software in the following order in order to ensure smooth
progress of the installation.
1. Connect the measuring transformer card
2. Installation of the drivers
3. Installation of the FCM software
The computer must be restarted after completion of the software installation.
Do not use the FCM until after the restart,
2.2
Two drivers must be installed for the measuring transformer card of the FCM. On the one hand, a driver
for the USB connection to the measuring transformer card and on the other hand a driver for the virtual
COM port. The measuring transformer card of the FCM is indeed connected to the computer via a USB
port, however it is necessary to treat this as a virtual COM port.
First connect the USB data carrier (USB stick) to a USB port of your PC. Then connect the measuring
transformer card to a USB port of your PC using the supplied USB cable. The New hardware found
wizard should now start automatically.
If this is not the case, select Start R Control Panel R Add new hardware.
www.h-tec.com
2.3
Run the setup program Setup.exe on the supplied installation data carrier and follow the instructions on the screen. If necessary, change the installation directory according to your requirements. After
successful installation, FCM can be started from the START->All Programs menu or from the desktop
shortcut.
Important:
The system must be restarted after the installation of the drivers and the software. Do not use FCM until
after the restart.
2.4
First Run
Only for U103 Fuel Cell Monitor Pro 3.0: The first start of Fuel Cell Monitor Pro 3.0 must be done with
the power supply plugged in.
1. If you have disconnected the USB connection after the installation, connect your computer and the
measuring transformer card using the supplied USB cable.
2. Start the program.
During the first run of the program, a dialogue window is displayed which requests you to connect the
measuring transformer card to the computer. Click on System Settings. Another window opens in
which the COM port which the card is connected to can be selected on the top right under Port for the
measuring transformer card. Click on OK after making the selection. The setting is thus saved. If the
dialogue window is displayed again, select a different COM port and/or check the USB connection.
10
www.h-tec.com
If the dialogue window is not displayed again, the FCM has a connection to the measuring transformer
card. Now you will be requested to disconnect any possibly connected fuel cells or electrolysers from
the measuring transformer card. The program performs a zero compensation. The Fuel Cell Monitor is
ready for operation afterwards. This is indicated by green and red flashing diodes on the measuring
transformer card. The program interface is now displayed on your screen (see Figure 2) which consists
of the following components:
D
Menu
Bar
B Graphs
A
Dial
instruments
C
Control
A. Dial instruments
The three dial instruments clearly show the current and maximum measured values. The pointers can
have three colours: The maximum value for voltage, current and power is displayed using a black pointer. A blue pointer displays the current value. This pointer is yellow after completion of the measurement.
The yellow pointer displays the so-called MPP (Maximum Power Point) - the point of the characteristic
curve at which the cell has its maximum power output. The values are also displayed again in the form of
numeric values under the dial instruments whereby the current value (blue - or in MPP yellow - pointer)
is displayed on the left and the maximum value on the right.
B. Graphs
The recorded measured values and their course are displayed in the four graphs in the form of function
graphs. A yellow cursor is displayed in the voltage/current graph after completion of the measurement.
11
www.h-tec.com
This shows the MPP of your cell. By clicking on the cursor and keeping the mouse button pressed, you
can drag it along the characteristic curve and thus let different measured values on the characteristic
curve be displayed.
C. Control
The type of the cell to be measured is specified here and measurements are started or stopped. Furthermore, you also have the possibility for certain measurements to input values (further information in
the chapter Measured value recording) and a progress bar is displayed for measurements where a
measurement duration can be specified.
D. Menu bar
Im Men des FCM werden u.a. die verschiedenen Messoptionen und Systemeinstellungen vorgenommen sowie Daten gespeichert. (Nheres im folgenden Kapitel Menpunkte)
2.5
Menu Items
This section briefly shows the menu items of the FCM. Please refer to the corresponding subitems in the
chapter Measured value recording for details about the individual measurement options.
File
Here, you can save the recorded measured data, display the screen as an HTML document or print it
under Report and end the program. The Exit option using the cross on the top right in the program
window is deactivated in order to ensure the proper shutdown of the software otherwise problems with
the port recognition can occur when the program is restarted.
Measurement Options
The fuel cell type (or electrolyser type for the extended Version U103 Fuel Cell Monitor Pro 3.0) and the
type of the measurement are specified in the Measurement Options menu item.
System Settings
Here you can select between the menu languages English, German, French and Spanish, set the port
for the measuring transformer card, specify the file path and the file format for the measured data to be
saved and select the axis assignment for current and voltage for the electrolysis measurement.
Help
You will find complete help for FCM in the Help menu.
12
www.h-tec.com
3.1
General
When the program is started, a window is displayed with the instruction to disconnect any possibly
connected fuel cells or electrolysers from the measuring transformer card. This is used for the zero
compensation of the FCM. Confirm with OK. The FCM is now ready for operation.
The FCM has automatic scaling during he characteristic curve recording. This means the axes of the
graphs are automatically optimally adapted to the measured values. After the measurement has ended,
you can also change the minimum and maximum values on the axes of the graphs manually in order, for
example, to display specified areas of the characteristic curve magnified. Click on any scale value on the
respective axis with the left mouse button and then input the desired value using the keyboard. Confirm
your input afterwards with Enter. The scaling changes in accordance with your input.
The menu is disabled after starting measurements. If you want to make changes in the menu after starting measurements, you must cancel the measurement or wait until the measurement is completed.
Before starting measurements, ensure that the fuel cell or the electrolyser is connected to the measuring
transformer card as shown in Figure 3.
Fuel Cell
Fig. 3: Connecting a fuel cell or an electrolyser
13
www.h-tec.com
3.2
3.2.1
The measured values are recorded at system-controlled intervals for the automatic characteristic curve
recording. A resistance is automatically changed from large to small values for this. The typical characteristic curve course for fuel cells is thus produced.
Note:
The automatic characteristic curve recording is particularly suitable for a fast and simple display.
Procedure:
Connect a fuel cell to the connection sockets of the measuring transformer card (see Figure 3).
Pay attention here to the correct polarity (red: plus and black: minus).
The value of the no-load voltage is now displayed in black by the top dial instrument and as a
numeric value on the right under the dial instruments. The FCM is now in standby mode.
Click on the Start button.
14
www.h-tec.com
The FCM now automatically records the characteristic curve of the fuel cell from the no-load
voltage to the short-circuit current, graphically displays the values and is again in standby mode
afterwards (see Figure 4).
The measurement can be cancelled at any time using the Cancel button.
Note:
When you start the FCM, it is automatically in the automatic characteristic curve recording of a fuel
cell mode. If you have performed a different measurement in the meantime, you can find the automatic
measurement again under the menu item Measurement Options R Fuel Cell R Automatic.
Note:
After the measurement is completed, you can move the cursor in the voltage/current graph by clicking
on the working point with the left mouse button and keeping the button pressed. The values are taken
over by the dial instruments and can be read there. Black pointer: maximum value; blue pointer: value at
the cursor position; yellow pointer: value at the cursor position in the Maximum Power Point (MPP).
15
www.h-tec.com
16
www.h-tec.com
It is also possible to input the current value directly using the control.
Click on the Start button.
The FCM now starts the specified current value, keeps it as constant as possible for the specified
measurement duration and is again in standby mode after the measurement.
The measurement can be cancelled at any time using the Cancel button.
Note:
After the measurement is completed, you can move the cursor in the voltage/current graph by clicking
on the working point with the left mouse button and keeping the button pressed. The values are taken
over by the dial instruments and can be read there. black pointer: maximum value; blue pointer: value at
the cursor position; yellow pointer: value at the cursor position in the Maximum Power Point (MPP).
Note:
The current-regulated characteristic curve recording is particularly suitable for long-term measurements. When setting a long measurement duration, the sampling rate can be set lower to reduce the
measured data.
17
www.h-tec.com
Note:
The menu is disabled as the FCM is performing the measurement.
Now select a working point on the characteristic curve in the voltage/current graph at which you
would like to measure the fuel cell (default MPP - yellow cursor). Click on the working point with
the left mouse button and keep it pressed to move the point.Click on Start again. The FCM now
starts this point of the characteristic curve and maintains it.
You also have the possibility to move the cursor on the characteristic curve during the running
measurement by clicking on the working point with the left mouse button and keeping it pressed.
The FCM then starts the new point whereby the new current and voltage values are adjusted. In
doing so, the resistance value is displayed as the quotient of voltage and current.
The measurement can be cancelled at any time using the Cancel button.
Note:
During a longer measurement, it can happen that the power of the cell increases if the cursor is moved
from the MPP. This initially seems illogical, however can be explained as follows: As this is a case of a
current-regulated measurement in the background, the FCM takes over the current value of the characteristic curve and multiplies this by the current voltage value. However, as the parameters (temperature,
humidity etc.) of the fuel cell change over longer operation, its power also changes, i.e. current and
voltage and thus also the characteristic curve. The voltage value of the characteristic curve therefore no
longer matches the current voltage. Remedy: Restart the measurement and let the fuel cell operate under load for a few minutes until it has reached its operating temperature before you start measurements.
The power output is then more constant.
Note:
After the measurement is completed, you can move the cursor in the voltage/current graph by clicking
on the working point with the left mouse button and keeping the button pressed. The values are taken
over by the dial instruments and can be read there. Black pointer: maximum value; blue pointer: value at
the cursor position; yellow pointer: value at the cursor position in the Maximum Power Point (MPP).
18
www.h-tec.com
3.3
Note:
The recording of stack individual voltages is only possible with the extended Version U103 Fuel Cell
Monitor Pro 3.0.
Procedure
Select Measurement Options R Stack Individual Voltages from the menu and input how many
cells your stack has (2 to 10).
Connect the individual voltage measurement cable to the COM connection of the measuring
transformer card and connect the measurement cables to the positive and negative poles of the
stack. Afterwards, connect the connectors of the individual voltage measurement cable to the
individual stack cells. Start at U1 on the negative side of the stack (see Figure 5).
U1 U2 U3 U4 U5 U6 U7 U8 U9 U10
COM connection
Fig. 5: Connecting a
stack to the individual
voltage measurement
cable
Measuring
transformer
card
19
www.h-tec.com
Note:
If you connect a stack with less than ten cells, start at U1 and connect the required number of measurement cables to the cells. Leave those not required disconnected (for example, in the case of a 5-cell
stack, you would need the first four measurement cables between U1 and U5).
Now click on the Start button. The characteristic curve of the fuel cell stack is first determined
automatically. A dialogue window is displayed after this has been completed. Click on OK if the
characteristic curve meets your expectations otherwise select Cancel. You can then restart the
automatic characteristic curve recording.
Note:
The menu is disabled as the FCM is performing the measurement.
Now select a working point on the characteristic curve in the voltage/current graph at which you
would like to measure the stack (default MPP - yellow cursor).
Click on the cursor with the left mouse button and keep it pressed to move the cursor.Click on
Start again. The individual voltage of the stack cells is now displayed and the total power of the
fuel cell stack in the power/time graph (see Figure 6).
20
www.h-tec.com
Note:
The working point cab also be changed during the running measurement by moving the cursor by clicking on the working point with the left mouse button and keeping it pressed.
Note:
If the measurement bar changes colour from blue to red during the measurement, this cell has no power.
Among other things, this can be due to insufficient supply of hydrogen or that a water drop is in in the
cell which prevents the supply of hydrogen. Remedy: check hydrogen supply; blow through the stack
with compressed air; let the stack warm up for some time.
Note:
If the individual voltages seem implausible to you, check whether the connector between U1 and U2
is on the negative side of the stack (see Figure 5).
Note:
During a longer measurement, it can happen that the power increases if the cursor is moved from the
MPP. This initially seems illogical and wrong, however can be explained as follows: As this is a case of a
current-regulated measurement in the background, the FCM takes over the current value of the characteristic curve and multiplies this by the current voltage value. However, as the parameters (temperature,
humidity etc.) of the fuel cell change over longer operation, its power also changes, i.e. current and
voltage and thus also the characteristic curve. The voltage value of the characteristic curve therefore no
longer matches the current voltage value Remedy: Restart the measurement and let the fuel cell operate
for a few minutes until it has reached its operating temperature before you start measurements. The
power output is then more constant.
3.4
Note:
The measurement of the efficiency is based on a simplified formula for the benefit of good usability. It
refers exclusively to hydrogen powered fuel cells from the company h-tec Wasserstoff-Energie-Systeme
GmbH.
The measured values are recorded at system-controlled intervals for the recording of the efficiency. A
resistance is automatically changed from large to small values for this. The typical characteristic curve
course for fuel cells is thus produced. Thereby, the red characteristic curve with the heat value and the
white characteristic curve with the fuel value are measured.
Procedure:
Connect a fuel cell to the connection sockets of the measuring transformer card (see Figure 3).
21
www.h-tec.com
3.5
Note:
The recording of electrolyser characteristic curves is only possible with the extended Version U103 Fuel
Cell Monitor Pro 3.0.
Important:
Absolutely ensure that an electrolyser or reversible fuel cell (RFC) has been connected. A fuel cell would be destroyed during the measurement as a voltage is applied to
the cell.
The electrolysis mode of the FCM is only designed for single and double cells of the
Junior and Tutorial product groups and for the h-tec Electrolyser65. Other electrolysers or RFCs with higher power cannot be measured.
Only use the power supply included in the standard delivery. If a different power
supply is used, the measurement result can be falsified or the measuring transformer card can be damaged.
22
www.h-tec.com
Procedure:
Select Measurement Options R Electrolyser R Automatic from the menu. If you have
previously performed an automatic fuel cell measurement, you can also select the mode on the
screen using the Start button.
Connect a single or double cell to the measuring transformer card using the measurement cables
(see Figure 3).
Connect the supplied power supply to the measuring transformer card.
Click on the Start button. A dialogue window is displayed. Check whether you have connected
a single-cell or double-cell electrolyser as a single-cell electrolyser would be destroyed in
the case of an accidentally started double-cell measurement. The h-tec Electrolyser65 is a
double cell. Now input the number of cells.
The FCM records the characteristic curve by increasing the voltage at the cell of 0-2 Volts for single cells
or 0-4 Volts for double cells (see Figure 7).
23
www.h-tec.com
Important information:
As each electrolyser is in principle also a fuel cell although with extremely low power, it can happen that
a no-load voltage is set after the electrolyser has already been measured. Due to this, another measurement at this electrolyser would not start at 0-0.1 Volts but under certain circumstances at significantly
higher values whereby the measurement result would be falsified and no correct characteristic curve
course would be produced.
Remedy: Flood the electrolyser with water again and then click on Fuel Cell in the control section and
start an automatic measurement. Check the no-load voltage after the automatic characteristic curve
recording; this should be less than 0.1 V. If this is not the case, repeat the process. Afterwards, you can
return to the electrolyser measurement using the control section.
Note:
The axes assignment for the electrolyser measurement can be defined under the System Settings
menu item. You can select a current over voltage or a voltage over current display.
3.6
Note:
The recording of efficiency characteristic curves of an electrolyser is only possible with the extended
Version U103 Fuel Cell Monitor Pro 3.0.
Important:
Absolutely ensure that an electrolyser or reversible fuel cell (RFC) has been connected. A fuel cell would be destroyed during the measurement as a voltage is applied to
the cell.
The electrolysis mode of the FCM is only designed for single and double cells of the
Junior and Tutorial product groups and for the h-tec Electrolyser65. Electrolysers or
RFCs with higher power cannot be measured.
Only use the power supply included in the standard delivery. If a different power
supply is used, the measurement result can be falsified or the measuring transformer card can be damaged.
Note:
The measurement of the efficiency is based on a simplified formula for the benefit of good usability. It
refers exclusively to electrolysers from the company h-tec Hydrogen Energy Systems.
24
www.h-tec.com
Procedure:
Select Measurement Options R Electrolyser R Efficiency from the menu. If you have
previously performed an automatic fuel cell measurement, you can also select the mode on the
screen using the Start button.
Connect a single or double cell to the measuring transformer card using the measurement cables
(see Figure 3).
Connect the supplied power supply to the measuring transformer card.
Click on the Start button. A dialogue window is displayed. Check whether you have connected
a single-cell or double-cell electrolyser as a single-cell electrolyser would be destroyed in
the case of an accidentally started double-cell measurement. The h-tec Electrolyser65 is a
double cell. Now input the number of cells.
The FCM records the characteristic curve by increasing the voltage at the cell of 0-2 Volts for single
cells or 0-4 Volts for double cells. Thereby, three efficiency characteristic curves are also displayed. The
output efficiency refers to the fuel value of hydrogen.
Important information:
As each electrolyser is in principle also a fuel cell although with extremely low power, it can happen that
a no-load voltage is set after the electrolyser has already been measured.
Due to this, another measurement at this electrolyser would not start at 0-0.1 Volts but under certain
circumstances at significantly higher values whereby the measurement result would be falsified and no
correct characteristic curve course would be produced.
Remedy: Flood the electrolyser with water again and then click on Fuel Cell in the control section and
start an automatic measurement. Check the no-load voltage after the automatic characteristic curve
recording; this should be less than 0.1 V. If this is not the case, repeat the process. Afterwards, you can
return to the electrolyser measurement using the control section.
3.7
The FCM provides the option to save recorded measured data (except stack individual voltages). The
path and the file type in which the data should be stored must be specified in the menu under System
Settings before saving measured data. Measurements can be saved either as standard text as .txt files
or as comma separated values in .csv files (.csv is a generally common text file format for saving data or
lists which can easily be imported by spreadsheet programs (such as, e.g. MS Excel or Open Office)).
Now you can save the last recorded measurement using File R Save measured data.
25
www.h-tec.com
A file is created in the specified directory which contains the values for time, voltage, current and power
as well as the time and the type of the measurement.
The file name is formed from the date and time as follows:
YearMonthDay_Hour-Minute-Seconds.txt (the same applies for the CSV file format). Thus a recorded measurement in the year 2009 on August 25 at 13:46 and 29 seconds would have the file name
090825_13-46-29.txt.
This type of naming convention guarantees a precise and unmistakable assignment of different measurements.
3.8
Report
The saving or the printout of the graphical display of the characteristic curves can be found under File
R Report. You have the options Print report and Open as HTML file. If you select Print, the
current screen of the FCM is printed out in grey scale. If you open the report with your web browser, the
current screen of the FCM is generated as an HTML file which you can save or otherwise process with
your web browser according to your requirements.
3.9
Four-terminal Sensing
The measuring transformer card of the FCM provides the possibility to perform all measurements as
four-terminal sensing. First connect the cell to be measured to the compensation cables i.e.: connect
the cell with the connection sockets for the four-terminal sensing (comp) to the measuring transformer
card. Then plug the plus and minus measurement cables into the compensation cables on the cell.
Pay attention here to the correct polarity (red=+ and black=-).
The special feature of the four- terminal sensing is that the voltage measurement is performed with a
lower (caused by the current) voltage drop and with a smaller influence of transition resistance. The
current and the voltage here are tapped using different measurement lines. Ideally considered, it can be
said (assuming an ideal voltmeter) that no current flows over the measurement lines to the voltmeter
and thus no voltage drop also occurs. The interfering influence is thus compensated for and the measurement is more precise.
26
www.h-tec.com
comp
Measuring transformer card
comp
Fuel Cell
Fig. 8: Connecting the measuring transformer card for four-terminal sensing
Maintenance
27
www.h-tec.com
Troubleshooting
Electrolyser measurement:
First ensure that no fuel cell is connected and whether the power supply and the electrolyser are connected to the measuring transformer card correctly.
The electrolyser does not have the stated power.
Cause: The electrolyser is not sufficiently supplied with water.
Solution: Flood the electrolyser again and/or fill the water tank of the electrolyser.
Cause: You have clicked on single-cell for the start of the measurement although you have connected
a double cell.
Solution: Ascertain which type of cell you have connected and start the measurement again.
28
www.h-tec.com
The screen display of the FCM does not show the desired homogeneous characteristic curve course.
possible causes:
There is no fuel cell connected.
The cell has been connected with the polarity reversed.
The cell is only connected to the connection sockets for the four-wire measurement.
The fuel cell is not sufficiently supplied with gas.
Solution: Check the connection of the cell to the measuring transformer card.
Possibly, an electrolyser with more power is needed.
29
www.h-tec.com
Technical Data
U103
U104
Item. No:
HxWxD:
Weight:
Connections:
U103
40 x 160 x 100 mm
1,4 kg
2 and 4 mm
Item. No:
HxWxD:
Weight:
Connections:
U104
40 x 160 x 100 mm
245 g
2 and 4 mm
0 - 10 V DC
0-5A
0 - 10 W
0 - 10 V DC
0-5A
0 - 10 W
0 - 4 V DC
0-3A
0 - 10 W
6V
3.33 A
Cable set:
2 x 4 mm measurement cables, red
2 x 4 mm measurement cables, black
2 x 2 mm measurement cables, red
2 x 2 mm measurement cables, black
2 x adapter
Individual voltage measurement cable
USB cable: Length 180 cm
30
Cable set:
2 x 2 mm measurement cables, red
2 x 2 mm measurement cables, black
2 x adapter
USB cable: Length 180 cm
www.h-tec.com
31