BFT Mizar 6

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

MIZAR 6

D811029 30-10-00 Vers. 03

CONTROL UNIT

MIZAR

1) GENERAL OUTLINE
MIZAR 6 mod. control unit has been designed to control one single
operator.

380

2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The Warnings leaflet and Instruction booklet supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of childrens reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/EEC, 73/23/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers components
are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of childrens reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
3) TECHNICAL SPECIFICATIONS
Power supply: .......................................................... 230V 10% 50Hz. (*)
Loadless absorption: .................................................................... 100 mA
Accessory output power: ............................................ 24Vac 200 mA max
Max. motor power absorbed: ........................................................... 500W
Limits switch: ....................................................................... electric switch
Working time: ....................................................... adjustable from 1 to 90s
Control panel dimensions: ........................................................... See fig.1
Case protection: ................................................................................ IP54

Working temperature: ............................................................... -20 +55 C


(*) Special voltages on request.
4) TERMINAL BOARD CONNECTIONS (Fig.2)
Keep the low voltage connections definitely separated from the power
supply connections.
M1A
1-2 Power supply 230V +/- 10% 50/60 Hz (Neutral wire to terminal 1).
3-4-5 M motor connection (terminal 4 common wire, terminals 3-5 motor
and capacitor operation).
1-4 Blinker connection 230V and Electric lock 230V mod. EBP.
M1B
7-8 Open-close push button and key selector (N.O.).
7-9 Stop button (N.O.). If not used, leave jumped.
7-10 Photocell or pneumatic edge input (N.C.). If not used, leave bridged.
7-11 Opening limit switch (N.C.). If not used, leave jumped.
7-12 Closing limit switch (N.C.). If not used, leave jumped.
13-14 24 Vac power supply output for photocell and additional devices.
15-16 Second radio channel output of the double-channel receiver board (N.O.)
17-18 Antenna input for radio-receiver board (18 braid - 17 signal).
CON1Radio-receiver board connector, 1-2 channels.
Fig.7 shows a general wiring diagram.
5) LED (Fig.3)
The MIZAR 6 control unit is provided with a series of self-diagnosis leds
which control all the functions.
The functions of the LEDs are the following:
(LD1 on - LD2 off) - Gate opening.
(LD1 off - LD2 off) - Gate stop.
(LD1 on - LD2 on) - Gate closing.
LD3 Start - goes on when a start command is given.
LD4 Closing limit switch - goes off when the closing limit switch is operated.
LD5 Opening limit switch - goes off when the opening limit switch is
operated.
LD6 Photocell - goes off when the photocells are not aligned or in the
presence of obstacles.
LD7 Stop - goes off when a stop command is given.
6) FUNCTIONING LOGIC
6.1) 4-step logic: (Dip-Fix IBL ON)
The following actions take place after a start command:
closed gate: ..................................................................................... opens
opening: ......................... stops and operates the TCA (Dip-Fix TCA ON)
open gate: ........................................................................................ closes
closing: ................................ stops (stops and does not operate the TCA)
after the stop: ................................................................................... opens
With Dip-Fix IBL ON, any start command given during opening has no effect.
6.2) 2-step logic: (on request)
The following actions take place after a start command:
closed gate: ...................................................................................... opens
opening: .......................... stops and operated the TCA (Dip-Fix TCA ON)
open gate: ......................................................................................... closes
closing: .............................................................................................. opens
after the stop: .................................................................................... opens
7) DIP-FIX SELECTION (Fig.3)
TCA Automatic closing time TCA.
ON: Automatic closing on.
OFF: Automatic closing off.
IBL Blocks impulses.
ON: START commands are not accepted during the opening phase.
OFF: START commands are accepted during the opening phase.
FCH Photocells.
ON: Photocells are only active in the closing phase. If an object is detected
by the photocells during the closing phase, the gate reverses the current
movement.
OFF: Photocells are active both in the closing and opening phase. If an
object is detected by the photocells on closing or opening, the gate stops;
once the object has been removed, the gate opens.
8) TRIMMER ADJUSTMENT (Fig.3)
TCA (Dip-Fix TCA ON)
It is used to set the automatic closing time, after which the gate closes

CONTROL UNITS

D811029_03

Thank you for buying this product, our company is sure that you will be more
than satisfied with the products performance. The product is supplied with
a Warnings leaflet and an Instruction booklet. These should both be
read carefully as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product is
in conformity with the following European Directives: 89/336/EEC and 73/
23/EEC (and subsequent amendments).

MIZAR
automatically (adjustable from 0 to 90 sec.).
TW
It is used to set the motor working time, after which the motor stop (adjustable
from 0 to 90 sec.). When using electrical limit switches, increase the motor
stopping time by a few seconds with respect to the leaf closing time.
9) ACCESSORIES
SPL (fig.4).
Pre-heating optional board. Recommended for temperatures below -10C.
ME (fig.5).
Optional board used to connect a 12Vac electric lock.
SS (fig.6).
Optional board signalling gate open. Operates only with electrical limit
switches.
EBP (fig.2).
The EBP electric lock with continuous service can be connected directly to
terminals 1 and 4.
10) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force. Batteries must be
properly disposed of.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product
features unchanged, at any time and without undertaking to update
the present publication.

D811029_03

381

CONTROL UNITS

MIZAR
Fig. 1

195

225

12

Fig. 2

90

18

2
3

Fig. 3

5
EBP
TCA

TW

NA
NC
382

NC
NC
NC

ST
BL
PHOT
SW.O
SW.C

0V
24V AC

8
9
10
11
12
13
14
15
16
17

ANTENNA
ANTENNE
ANTENNA
ANTENA
ANTENNE
ANTENA

18

D811029_03

MIZAR

IIRC

CONTROL UNITS

MIZAR
Fig. 4

10 11 12 13 14 15 16 17 18
24V AC

M1

MIZAR
* *

1 2 3 4 5 6

SPL
-8

+8
0

Fig. 5

Fig. 7

MIZAR
7

230V 40W

10 11 12 13
2 1

5 4 3 2 1

TX1

ME

STOP

230V

RX2

FL50-FL100

1 2 3 4

- -

12V

TX2

FOTOCELLULE
PHOTOCELLULES
PHOTOCELLULES
PHOTOZELLE
FOTOCELULAS
FOTOCLULAS

1 2

START

NC

NC

SWO.

SWC.

3
M1

4
5

EBP
COMM

ST

RX1

1 2 3 4 5

BL

9
PHOT

Fig. 6

SWO
SWC

24Vac

10
11
12
13
14

IIfl RC

MIZAR
2

10

11 12 13 14

15

D811029_03

SS

1 2 3 4

12V 3W

16
COSTA SENSIBILE
SENSITIVE EDGE
BARRE PALPEUSE
SICHERHEITSLEISTE
BARRA SENSIBLE
PERFIL SENSVELPERFIL SENSVEL

15

CONTROL UNITS

17
ANTENNA
ANTENNE
ANTENNA
ANTENA
ANTENNE
ANTENA

18

383

You might also like