Altivar 312 ATV312H075M2 Variador de Velocidade

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Product data sheet

Characteristics

ATV312H075M2

variable speed drive ATV312 - 0.75kW 1.8kVA - 60W - 200..240 V- 1-phase supply

Nov 25, 2014

Range of product

Altivar 312

Product or component
type

Variable speed drive

Product destination

Asynchronous motors

Product specific application

Simple machine

Assembly style

With heat sink

Component name

ATV312

Motor power kW

0.75 kW

Motor power hp

1 hp

[Us] rated supply voltage

200...240 V (- 15...10 %)

Supply frequency

50...60 Hz (- 5...5 %)

Network number of
phases

Single phase

Line current

7.5 A for 240 V


8.9 A for 200 V, 1 kA

EMC filter

Integrated

Apparent power

1.8 kVA

Maximum transient current

7.2 A for 60 s

Power dissipation in W

60 W at nominal load

Speed range

1...50

Asynchronous motor
control profile

Factory set : constant torque


Sensorless flux vector control with PWM type motor
control signal

Electrical connection

L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5


mm AWG 14
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A,
R2B, LI1...LI6 terminal 2.5 mm AWG 14

Supply

Internal supply for reference potentiometer (2.2 to


10 kOhm) at 10...10.8 V <= 10 mA for overload and
short-circuit protection
Internal supply for logic inputs at 19...30 V <= 100
mA for overload and short-circuit protection

Communication port
protocol

CANopen
Modbus

IP degree of protection

IP41 on upper part


IP31 on upper part
IP21 on connection terminals
IP20 on upper part without cover plate

Option card

Profibus DP communication card


Modbus TCP communication card
Fipio communication card
DeviceNet communication card
CANopen daisy chain communication card

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Main

Complementary
Supply voltage limits

170...264 V

Network frequency limits

47.5...63 Hz

Prospective line Isc

1 kA

Continuous output current

4.8 A at 4 kHz

Speed drive output frequency

0...500 Hz

Nominal switching frequency

4 kHz

Switching frequency

2...16 kHz adjustable

Transient overtorque

170...200 % of nominal motor torque

Braking torque

100 % without braking resistor


100 % with braking resistor continuously
150 % with braking resistor for 60 s

Regulation loop

Frequency PI regulator

Motor slip compensation

Adjustable
Automatic whatever the load
Suppressable

Output voltage

<= power supply voltage

Tightening torque

0.8 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/0.6 N.m Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6

Insulation

Electrical between power and control

Analogue input number

Analogue input type

AI3 configurable current 0...20 mA, impedance 250 Ohm


AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance 30000
Ohm
AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance 30000
Ohm

Sampling duration

LI1...LI6 4 ms for discrete


AI1, AI2, AI3 8 ms for analog

Response time

R1A, R1B, R1C, R2A, R2B 8 ms for discrete


AOV, AOC 8 ms for analog

Linearity error

+/- 0.2 % for output

Analogue output number

Analogue output type

AOV configurable voltage 0...10 V, impedance 470 Ohm, resolution 8 bits


AOC configurable current 0...20 mA, impedance 800 Ohm, resolution 8 bits

Discrete input logic

(LI1...LI6)Positive logic (source) state 0 < 5 V state 1 > 11 V


(LI1...LI6)Negative logic (source) state 0 > 19 V
(LI1...LI4)Logic input not wired state 1 < 13 V

Discrete output number

Discrete output type

(R2A, R2B) configurable relay logic NC, electrical durability 100000 cycles
(R1A, R1B, R1C) configurable relay logic 1 NO + 1 NC, electrical durability
100000 cycles

Minimum switching current

R1-R2 10 mA at 5 V DC

Maximum switching current

R1-R2 on resistive load, 5 A at 30 V DC, cos phi = 1, L/R = 0 ms


R1-R2 on resistive load, 5 A at 250 V AC, cos phi = 1, L/R = 0 ms
R1-R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, L/R = 7 ms
R1-R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, L/R = 7 ms

Discrete input number

Discrete input type

(LI1...LI6) programmable, 24 V 0...100 mA with PLC, impedance 3500 Ohm

Acceleration and deceleration ramps

Linear adjustable separately from 0.1 to 999.9 s


S, U or customized

Braking to standstill

By DC injection

Protection type

Thermal protection motor


Short-circuit between motor phases drive
Overheating protection drive
Overcurrent between output phases and earth (on power up only) drive
Motor phase breaks drive
Line supply phase loss safety function, for three phases supply drive
Line supply overvoltage and undervoltage safety circuits drive
Input phase breaks drive

Insulation resistance

>= 500 mOhm at 500 V DC for 1 minute

Local signalling

Four 7-segment display units for CANopen bus status


1 LED red for drive voltage

Time constant

5 ms for reference change

Frequency resolution

Display unit 0.1 Hz


Analog input 0.1...100 Hz

Type of connector

1 RJ45 Modbus/CANopen

Physical interface

RS485 multidrop serial link

Transmission frame

RTU

Transmission rate

4800, 9600 or 19200 bps Modbus


10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen

Number of addresses

1...247 Modbus
1...127 CANopen

Number of drive

31 Modbus
127 CANopen

Marking

CE

Operating position

Vertical +/- 10 degree

Height

145 mm

Width

72 mm

Depth

142 mm

Product weight

1.5 kg

Environment
Dielectric strength

2880 V AC between control and power terminals


2040 V DC between earth and power terminals

Electromagnetic compatibility

Radiated radio-frequency electromagnetic field immunity test conforming to IEC


61000-4-3 level 3
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
1.2/50 s - 8/20 s surge immunity test conforming to IEC 61000-4-5 level 3

Standards

IEC 61800-3
IEC 61800-5-1

Product certifications

CSA
C-Tick
DNV
GOST
NOM
UL

Pollution degree

Protective treatment

TC

Vibration resistance

1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6


1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to EN/IEC 60068-2-27

Relative humidity

5...95 % without dripping water conforming to IEC 60068-2-3


5...95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for storage

-25...70 C

Ambient air temperature for operation

-10...60 C with derating factor without protective cover on top of the drive
-10...50 C without derating with protective cover on top of the drive

Operating altitude

1000...2000 m with current derating 1 % per 100 m


<= 1000 m without derating

Offer Sustainability
Sustainable offer status
RoHS

Green Premium product


Compliant - since 0913 -

Schneider Electric declaration of conformity

Product environmental profile

Available

Product end of life instructions

Need no specific recycling operations

Download Product Environmental

You might also like