EJ Series Butterfly Valves
EJ Series Butterfly Valves
EJ Series Butterfly Valves
EJ Series
Butterfly Valves
Materials
Flange Table
Parts
Standard
Materials
Body
Ductile ironEN-GJS-450-10
Stem
Disc
Seat
W-NBRWhite NBR
Size
inch
mm
BS EN 1092
BS10
ASME B16.5
PN6
PN10
PN16
Table E
Class150
50
2 1/2
65
VMQSilicone rubber
80
FKMFluoro rubber
100
O-ring
FKM
125
Bearing
Stainless Steel
150
Stem bearing
Multi-layered bearing*
200
Plug
Zinc die-cast
10
250
Bottom stem
12
300
Standard mounting
Special mounting (Proper centering is required)
G PN10 EJ M W
2
Lever handle
Gear
4 Disc material
M:
2 Class
1 Valve operation
None:
G:
PN10
EJ:
5 Seat material
W:
Q:
F:
W-NBR
VMQ
FKM
Please consult KITZ sales staff or our local agent for details of the seat and the disc combination
Please consult KITZ sales staff or our local agent for vacuum service.
Contents
Design features
Technical specifications
Approved
PN10EJM
G-PN10EJM
Bolting data
Precautions
Design feature
Bearing
ISO5211 Actuator
mounting Flange
O-ring
Stem
High performance
stem bearing
Back up ring
Disc
Body
3 type of Seat material
Bottom stem
Back up ring
High performance
Stem bearing
Plug
All the sizes are suitable for the flanges of EN1092 PN6, PN10,
PN16 / BS10 Table E / ASME Class125 and Class150
The backup ring around the stem maintains the performance of the
stem sealing caused by the movement of the stem / disc in the
sealing / seat of valve.
Polished disc.
The polished disc is standard for VMQ and optional for W-NBR
seats for use within the food and pharmaceutical industry.
Technical Specifications
P-T rating
W-NBR seat
10bar
10bar1.0MPa
Body material
Ductile iron
*1 Obsolete Standard.
0bar
Applicable standards
Valve design
80
VMQ seat
10bar
EN 593:2004
7bar
Coupling flanges
Wafer type
5bar
3bar
BS10 Table E
0bar
-20 0
100
150
180
FKM seat
Technical Data
10bar
7bar
Pressure loss
10
Pressure dropkPa
50A
55A
80A
100A
125A 150A
200A
0.1
100
130
180
: Continuous service
300A
10
100
Flow volumem3/h
1000
Size
mm inch
2
50
2 1/2
65
80
3
100
4
125
5
150
6
200
8
250
10
300
12
Flow characteristics
100
90
80
Flow rate (%)
70
60
50
40
20
30
17
36
45
65
95
138
241
325
493
40
29
60
75
109
160
234
419
575
859
Open degree
50
60
56
42
122
88
165
113
274
172
406
255
598
375
681 1080
950 1510
1410 2260
70
75
172
248
446
655
958
1700
2420
3610
80
86
219
345
689
997
1430
2470
3460
5160
Kv = Cv / 1.167
10
0
20
8
16
21
3
47
68
116
160
258
30
10 20
30 40 50
60 70 80
0bar
250A
90
90
88
246
415
886
1250
1760
2900
4020
6010
Certificates
KITZ has always firmly believed that its Products and Service must be backed by the most demanding. Approvals and Certificates, as clear
proof of maximum quality assurance. This has resulted in an ongoing detail improvement of our products and service.
ISO 9001
ATEX
Options
Polished disc.
Gear operated
Size 50 to 200 (standard for 250 and over)
PN10EJM
of product coding
are trim material coding
For trim material coding,
please refer to page 3.
D1
SIZE 80
SIZE 5065
H1
dD
H2
SIZE 125150
SIZE 200
BS PN10 Design
Dimensions
Valve Size
inch
mm
2
50
21/2
65
3
80
4
100
5
125
6
150
8
200
H1
H2
D1
50
65
79
100
125
147
197
191
199
217
227
265
277
287
147
155
173
183
211
223
248
67
75
91
101
127
139
169
43
46
46
52
56
56
60
90
104
124
146
176
206
257
125
145
160
180
210
240
295
180
180
180
180
230
230
350
PN10EJ
of product coding
are trim material coding
For trim material coding,
please refer to page 3.
E
F
L1
D1
H1 H
d D
H2
BS PN10 Design
Dimensions
Valve Size
inch
mm
10
250
12
300
H1
H2
D1
L1
245
295
381
406
304
329
229
254
68
78
316
367
355
410
250
250
250
250
60
60
63
63
Bolting Data
Hexagon head boltHexagon nut
L=mm
Flange
PN6
PN10
PN16
BS 10 TalbeE
inch
Size
No.
Size
No.
Size
No.
50
M12
90
M16
105
M16
105
5 /8
65
21/2
M12
90
M16
105
M16
105
5 /8
80
M16
100
M16
105
M16
105
5 /8
100
M16
110
M16
115
M16
115
5 /8
125
M16
115
M16
115
M16
115
5 /8
150
M16
115
M20
120
M20
120
3 /4
200
M16
125
M20
130
M20
140
12
3 /4
250
10
M16
135
12
M20
140
12
M24
155
12
3 /4
300
12
M20
150
12
M20
155
12
M24
170
12
7 /8
No.
Size
No.
Size
No.
Size
mm
Size
No.
Size
No.
95
5 /8
105
100
5/8
115
100
5/8
115
110
5/8
125
115
3/4
130
115
3/4
135
125
3/4
145
140
12
7/8
160
12
160
12
7/8
170
12
No.
Size
No.
120
5 /8
120
120
5/8
130
PN6
Flange
Size
PN10
L
PN16
L
BS 10 TalbeE
mm
inch
50
M12
110
M16
125
M16
125
5/8
65
21/2
M12
110
M16
130
M16
130
5 /8
80
M16
120
M16
130
M16
130
5 /8
120
5/8
130
100
M16
130
M16
135
M16
135
5 /8
130
5/8
150
125
M16
140
M16
140
M16
140
5 /8
140
3/4
160
150
M16
140
M20
145
M20
145
3 /4
140
3/4
160
200
M16
150
M20
155
M20
165
12
3 /4
150
3/4
170
250
10
M16
160
12
M20
170
12
M24
185
12
3 /4
160
12
7/8
190
12
300
12
M20
180
12
M20
185
12
M24
200
12
7 /8
190
12
7/8
200
12
5. For valve mounting, set jack bolts under the pipes for
flat support at the same height, and adjust the flangeto-flange distance so that some 6 mm to 10 mm room
may be allowed beside the both sides of the valve
body.
Remember that valves here must be left open only by
10 from the fully closed position.
6. Mount Valve carefully so that flange faces may not
damage resilient seats. (Fig. 2)
7. Then set bolts into the guides of a valve, ensuring
the correct centering between pipes and the valve.
8. Trially open the valve to check to see if there is no
disturbing contact between the valve disc and the
flanges.
Recommended torque values
9. Remove the jack bolts,
Nm (kgfm)
DN
tighten bolts alternately
50
and diagonally till the
65
63(6)
flanges contact the valve
80
body (Fig. 3 and 4).
100
125
Refer to the table shown
111(11)
150
right for recommended
200
torque values.
250
300
Fig. 2
177(18)
Fig. 3
Fig. 1
(a)
Fig. 4
(b)
GOOD
Centrifugal pump
(Vertical shaft)
GOOD
10D
Centrifugal pump
(Horizontal shaft)
Do not use
GOOD
Pump
shaft
10D
Pump
shaft
Do not use
GOOD
10D
Axial flow pump
Valve Operation
1.Valves equipped with manual operators such as
levers, and handles of gears must be ONLY
MANUALLY operated. Application of an excessive
exter nal force to operate valves may result in
malfunction of valves and their operators.
2.Ensure to fully open valves before a loop test of the
piping system is carried out with line pressure higher
than the nominal pressure of tested valves. Never use
closed valves in place of blind flanges.
3.When valves need to be dismantled from pipes for
maintenance or any other cause, ensure to thoroughly
releave the line pressure beforehand. Loosening
piping bolts under line pressure causes a danger. Any
residual fluid left inside the pipeline must be
completely drained.
4.Users should contact KITZ Corporation or its local
distributors for technical advice, when valves should
be continuously pressurized while left open by 30 or
less.
5.Don't use position indicators to operate valves, or
overload position indicators. This may cause damage
to indicators.
6.Ensure to use blind flanges when butterfly valves are
mounted at the end of pipelines.
7.Standard actuators are referenced in this catalog for
actuated valve operation. Contact KITZ Corporation or
its local distributors for mounting optional actuators.
8.Contact KITZ Corporation for service at hopper or
pump outlets.
9.Avoid touching gear operators and actuator stopper
bolts accidentally.
10.It is recommended to perform periodical inspection for
Making sure of valve opening degree
Checking loosened bolts and leakage at each
connection
Checking vibration and noise
11.Refer to instruction manual for other precautions. Also
refer to actuator catalogs and instruction manuals for
actuated valves.
0908ITP