Realization of Upgraded
General-Purpose Actuators
The modularization and the adoption of common parts have brought
signicant advantage to EXS and EXH series, such as:
Better Cost Performance
Easiness
Manual Override
Position Indicator
1
2
1
2
Interlock Switch
The Interlock switch will cut off power
supply by being pulled it up, which will
ensure safe manual operation.
The manual mode can be indicated by
output signal.
3
4
Various capacitors
for different voltages
Circuit board
Terminal box
Optional specification
Power supply
AC110V 50/60Hz
EXH EXS
EXH EXS
AC115V 50/60Hz
AC120V 60Hz
Including four standard limit switches, total six switches can be used.
(In case the potentionmeter is used, four limit switches in total can be
used at maximum.)
AC220V 50/60Hz
AC230V 50/60Hz
AC240V 50Hz
AC115V 50Hz, AC120V 60Hz, AC230V 60Hz, AC240V
Allowable fluctuation of supply voltage is limited within between minus
10% and plus 5% for 50Hz.
Relays
EXH EXS
EXH EXS
Potentio-meter output
135 (Coil type)
EXH EXS
Terminal box
G1/2 two conduit ports
EXH
Conduit port
G3/4, NPT1/2, NPT3/4, M20
EXH EXS
Specification
High-speed type For ball valve
EXH100/200-1
EXH100/200-2
EXH100/200-3
EXH100/200-4
EXH100/200-5
EXS100/200-2
EXS100/200-3
EXS100/200-4
EXS100/200-5
Power Supply
Output Torque
(Nm)
Rated Current
(A) *1
9.8
49
196
588
1000
100V AC
0.65
0.65
1.2
2.8
2.8
200V AC
0.35
0.35
0.6
1.5
1.5
85
85
Motor Type
Reversible
Motor Output
(W)
(Rating)
16
16
Rotating Direction *2
Duty Factor
31
[%ED]
30
30
30
30
30
EXH 50Hz
14
21
28
49
EXH 60Hz
12
17
23
41
EXS 50Hz
25
35
49
49
EXS 60Hz
21
30
41
41
100V AC
15
15
15
15
15
200V AC
15
15
15
15
15
Insulation Class
JIS Class E, Strength: 1500V AC 1min. or 1800V 1sec., Resistance: 100 minimum at 500V DC
Overload Protection
Thermal protection
Service Environment
Equivalent to IP-67
Ambient Temperature
-10C ~ +50C
Conduit Port
EXH
One G1/2
EXS
Two G1/2
Mounting Position
Manual Operation
Pull up the manual override handle knob for manual operation, which will activate the built-in interlock switch
to cut off power supply. For the restoration of electrical operation, push down the handle knob
Mechanical Stopper
EXH
Mechanical stoppers are equipped in open and closed position. The stoppers are adjustable by 7 degrees
in the both positions
EXS
Mechanical stoppers, which can be adjusted in the closed position, are equipped in open and closed position
Position Indicator
Position indicator, covered by transparent cover, is equipped on the top of the actuator cover
Mounting Flange
*1 As the actuator is subjected to approx. tenfold rated current at startup, the contacts of electrical devices connected to the actuator must have enough capacity to handle this large electrical current.
*2 Refer to Operation manual for 3 way valves.
*3 Valve closing time is calculated based on an unloaded condition without the valve being mounted. The closing time will be 10% slower, when the valve is mounted.
*4 In case load current is 50 mA or smaller, use limit switches for micro load (minute current).
Circuit Diagram
Product Code
Scope of supply
(6) 15
(6) 14
EX
(4)
7
Load
Space heater
6
(6) 13
Actuator size
EXS: 2345
EXH: 12 3 4 5
5 (6)
(6) 12
4 (6)
(4) COM
(Close)
Switch
COM
(1)
SLS
SLS1
NO
Motor (2)
NC
NO
NC
(1)
Capacitor
AC
Power supply
100/200V
(Open)
50/60Hz
110/220V 50/60Hz
115V 60Hz
230V 50Hz
COM
(1)
OLS
COM
10
NO
NC
(4) COM
OLS1
NO
NC
11
NO
NC
(1)
8
Power supply
100 : AC100V
200 : AC200V
Type
EXS: Standard speed actuator for ball valves
and butterfly valves.
EXH: High speed actuator for ball valves.
Dimensions
W
Type EXH
D3
D3
EXH100/200-5
H4
E3
H5
E2
D5
D3
EXH100/200-4
H1
Ground
EXH100/200-3
H2
D2
D1
E5
Type
EXH100/200-1
EXH100/200-2
EXH100/200-3
EXH100/200-4
EXH100/200-5
E1
129
129
152
168
168
E2
54
54
69
73
73
E3
30.4
30.4
45.1
51.3
51.3
t1
H3
t2
D4
EXH100/200-1,2
E6
E4
E5
33.5 99.5
33.5 99.5
42
123
50
138.5
50
138.5
E6
28.5
28.5
28.5
28.5
28.5
W
131
131
158
188
188
H1
181
181
206.5
276
357
H2
37
37
44
78
159
H3
12
12
19
53
134
H4
10
10
10
10
10
H5
107.5
107.5
117.5
153
153
D1
50
50
50
70
D2
70
70
70
102
D3
102
125
140
D4
35
35
55
55
100
D5
40
40
60
60
60
16
16
25
34
65
t1
2
2
2
2
3
unit: mm
t2
1
1
1
1
W1
Type EXS
E4
W2
D3
EXS100/200-5
E3
E1
Position of handle on manual operation mode.
H5
E2
H6
D3
D5
H1
H2
H1
D3
EXS100/200-4
Ground
EXS100/200-3
D4
H4
t1
H3
t2
H3
D2
D1
H4
E5
G with conduit plug
In case of EXS-4
Type
EXS100/200-2
EXS100/200-3
EXS100/200-4
EXS100/200-5
E1
206.5
230
245.5
245.5
EXS100/200-2
E6
E2
54
69
73
73
E3
30.4
45.1
51.3
51.3
E4
E5
33.5 98
42
121.5
50
137
50
137
E6
40
40
40
40
W1
131
158
188
188
W2
132
132
132
132
H1
181
206.5
276
357
H2
204
222.5
258
258
H3
37
44
78
159
H4
23
16
18
99
H5
10
10
10
10
H6
107.5
117.5
153
153
D1
50
50
70
D2
70
70
102
D3
102
125
140
D4
35
55
55
100
D5
40
60
60
60
16
25
34
65
t1
2
2
2
3
unit: mm
t2
1
1
1
Actuator Sizing
Sizing condition: Ball valve
Service condition
Fluid type
Fluid
Clean fluid
Water, Lubricant
Standard sizing
Standard sizing
Solvents *1
Vacuum or Oil free service
Service temperature
Velocity (Liquid)
3m/sec or slower
Shell
materials
Type / Bore
Class
JIS 10K
Stainless
Steel
Flanged
Carbon
Steel
Ball Valve
/ Full Bore 3way
Stainless
Steel
Ball valve
/ Full Bore PFA Lining
Aluminum
Butterfly Valve
Ductile Iron
Stainless
Steel
25
32
40
50
65
3/4
11/4 11/2
21/2
10FCTB
EXH-4
(EXS-4)
10STBF
150SCTDZ
10
12
EXH-5
(EXS-5)
Flanged
Class 300
EXH-3
(EXS-3)
EXH-4
(EXS-4)
10SCTDZ
300UTDZ
20UTDZ
20SCTDZ
Flanged
150UTR
EXH-2
(EXS-2)
300UTR
EXH-3
(EXS-3)
150SCTR
EXH-4
(EXS-4)
10UTB4T(L)A Note1
EXH-2
10UTBLN
EXH-1
EXH-3
EXH-2
EXH-4
EXH-3
EXS-3
10UB
16UB
EXS-4
EXS-2
16DJ, PN16DJ
JIS 16K
Note2
10DJ
JIS 10K
10XJSME Note2
Wafer
300SCTR
10XJME
JIS 10K
JIS 16K
BS PN16
EXH-2
(EXS-2)
300SCTDZ
JIS 10K
Class 150
JIS 20K
Class 300
Flanged
JIS 10K
Class 150
JIS 20K
Class 300
JIS 10K
EXH-1
EXS-4
Dimensions of flange
Actuator
16
EXH-1
14
10UTDZ
JIS 10K
JIS 20K
Ball Valve
/ Reduced Port
20
1/2
150UTDZ
Stainless
Steel
15
inch 3/8
Threaded 10UT
Class 150
Stainless
Steel
/Carbon
Steel
Size mm 10
Threaded 10FCT
Cast Iron
Ductile Iron
Connection
Product
code
ISO Flange
F05 + F07
Axis depth
16
EXH-2
EXS-2
F05 + F07
35
11
16
EXH-3
EXS-3
55
17
25
EXH-4
EXS-4
EXH-5
EXS-5
F14
55
27
34
100
65
EXH-5
(EXS-5)
Precautions
CAUTION
E nsure
aware that rust may develop in the valves, which may damage the ball
seats, leading to operation failure. Pay extra attention on valve
selection and protection from rust.
Connect cables correctly in accordance with the circuit diagram.
Ensure to use a terminal base when connecting cables.
A fter connecting cables, conduct an insulation resistance test to
ensure its insulation.
Ensure the housing is securely sealed with such sealing materials as
O-rings to prevent dust or water from entering the housing.
DO NOT try to operate two or more actuators at the same time with
only one operation switch. Other electrical equipment should not also
be operated at the same time with one operation switch.
Ensure the space heater to be activated all the time to keep the inside
of the actuator warm for the prevention of due condensation, which
may result in operational malfunction.
E nsure the actuator is powered off, when it is used for manual
operation.
Place at least one-second interval, when the direction of operation is
reversed. Failure to follow this instruction may result in operation
malfunction.
DO NOT make any unauthorized modifications. Such modifications
may result in causing a troubled operation or accidents. We shall not
be responsible for any troubles or accidents caused by improper use
of the products.
Refer to our catalogs for more details on valve information.
WARNING
This
product is not designed for explosion-proof. DO NOT use it in any inflammable or corrosive gaseous environment. Also DO NOT use it for
handling inflammable fluid.
DO NOT disassemble the actuator while the unit is being energized.
DO NOT put your fingers or insert any foreign objects within the valve core before or during valve operation.
E-312 06
Pressure-temperature ratings and other performance date published in this catalog have
been developed from our design calculation, in-house testing, eld reports provided by our
customers and / or published ocial standards or specications. They are good only to cover
typical applications as a general guideline to users of KITZ products introduced in this catalog.
For any specic application, users are kindly requested to contact KITZ Corporation for
technical advice, or to carry out their own study and evaluation for proving suitability of
these products to such an application. Failure to follow this request could result in property
damage and / or personal injury, for which we shall not be liable.
While this catalog has been compiled with the utmost care, we assume no responsibility for
errors, impropriety or inadequacy. Any information provided in this catalog is subject to
from-time-to-time change without notice for error rectication, product discontinuation,
design modication, new product introduction or any other cause that KITZ Corporation
considers necessary. This edition cancels all previous issues.
Read instruction manual carefully before use.
If any products designated as strategic material in the Foreign Exchange and Foreign Trade
Law, Cabinet Ordrer Concerning Control of Export Trade, Cabinet order Concerning Control
of Foreign Exchange and other related laws and ordinances ( Foreign Exchange Laws ) are
exported to any foreign country or countries, an export license issued by the Japanese
Government will be required under the Foreign Exchange Laws.
Further, there may be cases where an export license issued by the government of the United
States or other country will be required under the applicable export-related laws and
ordinances in such relevant countries.
The contract shall become eective subject to that a relevant export license is obtained from
the Japanese Government.
Printed in Japan
1305ITP