Programmable Digital Room Thermostat: Operating Instructions
Programmable Digital Room Thermostat: Operating Instructions
Programmable Digital Room Thermostat: Operating Instructions
COMPUTHERM Q7
NEW
software!
Operating Instructions
Set temperature
Manual control indicator
Programme number
Timed manual control
indication
Current temperature
of the room
Vertical angle:
30 - 45
Latch
flashing, the thermostat goes to the main screen and the setting
process can be started.
3.2 Setting the current day and time
Press the SET button to go to the main screen, then press the
DAY button. At this time only the serial number of the day will flash
on the display of the thermostat and the hour and minute values can
be seen.
Using the large
and
buttons on the front panel of the device,
set the serial number of the current day (Monday 1; Tuesday 2;
Wednesday 3, etc.). Press the DAY button again. At this time
the number indicating the day stops flashing and becomes visible
continuously while the numbers indicating the hour will flash on the
display. Using the large
and
buttons on the front panel of the
device, set the hour value of the current time. Press the DAY button
11
again. At this time the numbers that indicate the hour stop flashing
and become visible continuously, while the numbers indicating the
minute will begin flashing. Using the large
and
buttons on the
front panel of the device, set the minute value of the current time.
When you wish to continue modifying the settings, please press the
DAY button again. If you wish to finish settings, confirm them by
pressing the SET button. At this point adjusted data are recorded
and the device goes back to the main screen (if no buttons are pressed
for at least 15 seconds, the settings are automatically confirmed and the
device goes back to the main screen).
3.3 Switching between the heating and cooling mode
There is a possibility to easily switch between the heating and cooling
mode of the thermostat. The output terminals No. 1 and No. 2 of the
thermostat are closed below the set temperature in heating mode, and
12
they are closed above the set temperature in cooling mode (taking
the switching sensitivity into account). The closed state of the output
terminals No. 1 and No. 2 are indicated by the
icon in the bottom
left corner of the display in case of both modes.
To switch between the two modes, first press the SET button to go
to the main screen. Then press the SET button again and hold it
down and press the COPY button, too. After this, the notice HE AT
or
appears in place of the time characters, according to the
selected mode. Following this, switch between the modes using
the large
and
buttons, then confirm it by pressing the SET
button (if no buttons are pressed for at least 15 seconds, the setting is
automatically confirmed). After this confirmation, the device goes back
to the main screen.
13
sensitivity for heating systems with low thermal inertia (e.g. flat
panel radiators).
To change the switching sensitivity, first press the SET button to go
to the main screen. Then press the DAY and COPY buttons one
after the other. Following this, select the desired switching sensitivity
using the large
and
buttons. The notices S:1 , S:2 and S:3
indicate 0.1C, 0.2C and 0.3C, respectively. Finally, confirm
the setting by pressing the SET button (if no buttons are pressed
for at least 15 seconds, the setting is automatically confirmed). After
this confirmation, the device goes back to the main screen.
3.5 Activation of the pump protection function
Under the factory default settings, the pump protection function is
inactive. In order to activate or deactivate it, first press the SET
15
button to go to the main screen. Then press the DAY and PROG
buttons one after the other. Following this, activate or deactivate this
function using the large
and
buttons. The notices HP:ON and
HP:OF indicate activated and deactivated state, respectively. Finally,
confirm the setting by pressing the SET button (if no buttons are
pressed for at least 15 seconds, the setting is automatically confirmed).
After this confirmation, the device goes back to the main screen.
To prevent the pump from sticking, the activated pump protection
function switches on the boiler for a one minute period at 12:00 p.m.
every day outside the heating season. (The pump protection function
can accomplish its task only if the boiler is in working order in the
summer, too. It is reasonable to set a low temperature level, e.g.
+10C, on the thermostat for this period, to prevent the boiler from
unnecessary start-ups when the weather turns cold temporarily).
16
and HOLD buttons one after the other. After this, the notice
appears in place of the time characters, and the correction value
appears in place of the measured temperature (0.0C by default).
Following this, set the desired correction value using the large
and
buttons between -3.0C and +3.0C, in 0.1C increments.
Finally, confirm the setting by pressing the SET button (if no buttons
are pressed for at least 15 seconds, the setting is automatically
confirmed). After this confirmation, the device goes back to the main
screen. The correction of the measured temperature takes effect a
couple of seconds after the confirmation.
17
of days). But be aware: if the program of all the days are created
together, than their program can only be modified together.
Therefore, if a different program is needed for at least one day,
then the program of the days should be created separately, and the
repeated programs should be copied using the COPY button.
A separate program can be created for the heating and cooling
mode, and these programs are preserved when switching between
the modes. Therefore, if the thermostat is used for both heating and
cooling, then there is no need to modify the program of the thermostat
every time a switch between these modes is performed.
4.2 Recommendations for creating a heating program
The average comfort needs of a person can usually be satisfied by
a temperature of 19-21C during the night, and a temperature of 2223C during the day. During that time of the day, when the family is
22
00:00
P1
05:30
P2
07:00
P3
15:00
P4
22:00
23
20 C
22 C
18 C
22 C
20 C
Temperature
Time
00:00
20 C
5:30 7:00
22 C 18 C
15:00
22 C
24
22:00
20 C
29
After selecting the number that indicates the day to which you wish
to copy the program, press the COPY button to copy the program.
Hereafter, the number indicating the day to which the program was
copied will be visible continuously. Following this, you can select
further days using the large
and
buttons and copy the
program to those days too by pressing the COPY button.
Finally, press the SET button to save the modifications (if no
buttons are pressed for at least 15 seconds, the modifications will
be automatically saved). Afterwards, the device goes back to the
main screen. If required, the program of further days can be freely
copied by repeating the above steps.
Attention! The COPY function is only available, if the days of the
week were programmed separately!
30
32
press the
button several times in increments of 0.5C. Following
this, using the large
and
buttons, the temperature can be
further modified in increments of 0.5C, in accordance with current
requirements.
The economy and comfort temperature values assigned to
buttons
and
can be modified as follows:
To set the economy temperature, press the SET button and
button, too. Following this, with
keep it depressed and press the
and
buttons, set the economy temperature
the help of the
selected by you. After the temperature has been set, press the
SET button to save the modification (after approximately 15
seconds, it is automatically saved). Afterwards, the device goes
back to the main screen.
35
To set the comfort temperature, press the SET button and keep
button, too. Following this, with
it depressed and press the
and
buttons, set the comfort temperature
the help of the
selected by you. After the temperature has been set, press the
SET button to save the modification (after approximately 15
seconds, it is automatically saved). Afterwards, the device goes
back to the main screen.
5.1 Temperature modification until the next program switch
and
buttons on
Set the required temperature using the large
the front panel of the device. At this time, the
icon appears on
the display, indicating that the thermostat is operated with manual
control. The device will control the boiler according to the set value
until the time of the next switch specified in the program is reached.
36
39
set program before the time set for temperature modification has
expired, please press the SET button.
5.4 Temperature modification until the next manual interference
and
buttons on
Set the required temperature using the large
the front panel of the device. At this time, the
icon appears on
the display, indicating that the thermostat is operated with manual
control. Then, press the HOLD button briefly, after which the
icon appears and the
icon disappears. The device will then
control the boiler according to the set value until the next manual
interference. During this time, the thermostat acts exactly the same
way as a non-programmable thermostat. The adjusted temperature
can be freely changed during this temporary modification without
exiting it.
40
If you wish to return to the set program, please press the SET
button.
6. TURNING ON THE BACKGROUND LIGHT
When you press the LIGHT button, the background light of the
display will turn on for 15 seconds. When you press another button
while the display is illuminated, the background light will turn off
only after 15 seconds have elapsed since the last button had been
pushed.
7. LOCKING THE CONTROL BUTTONS
The thermostat enables you to lock its control buttons. With this
function, you can prevent unauthorised modification of the program
41
or the set temperature. To activate the lock, first press the SET
and
buttons
button to go to the main screen, then press the
together and hold them down for at least 5 seconds. After the control
buttons have successfully been locked, the notice
appears in
place of the time characters for a couple of seconds. Until the control
buttons are locked, their normal function do not work; if any button
is pressed, then only the notice
appears and nothing else
happens. To unlock press the
and
buttons together and hold
them down for at least 5 seconds. After unlocking the buttons, the
notice
appears in place of the time characters for a couple of
seconds, whereupon all the buttons can be used normally again.
42
43
44
TECHNICAL DATA
switchable voltage:
switchable current:
temperature measurement range:
adjustable temperature range:
temperature measurement accuracy:
temperature calibration range:
selectable switching sensitivity:
storage temperature:
battery voltage:
power consumption:
battery lifetime:
dimensions:
weight:
temperature sensor type:
45