0% found this document useful (0 votes)
139 views4 pages

Design of Column at C (Intermediate Column)

The column is designed to resist an axial load of 3278.5 kN and bending moments of 54.47 kN-m and 40.71 kN-m. The column dimensions of 350x450 mm satisfy design checks for eccentricity and slenderness ratio. The column also satisfies interaction checks between axial load and bending moments. Reinforcement of 4-32 mm bars and 4-28 mm bars with 8 mm lateral ties at 300 mm pitch is designed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views4 pages

Design of Column at C (Intermediate Column)

The column is designed to resist an axial load of 3278.5 kN and bending moments of 54.47 kN-m and 40.71 kN-m. The column dimensions of 350x450 mm satisfy design checks for eccentricity and slenderness ratio. The column also satisfies interaction checks between axial load and bending moments. Reinforcement of 4-32 mm bars and 4-28 mm bars with 8 mm lateral ties at 300 mm pitch is designed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

[All references are from IS: 456-2000 except otherwise mentioned]

Design of Column at C (Intermediate Column)


Total axial load on the column = 546.423 6 = 3278.538 KN
MUX = 54.47 KN-m
MUY = 40.71 KN-m
Size of column = 350 mm 450 mm
Check for Eccentricity:
[Cl 25.4]
e=

l
500

b
30

3000
500

450
30

= 21 mm > 20 mm

e = 21 mm

0.05D = 0.05 450 = 22.5 mm > e


Hence O.K.
Check for Slenderness Ratio:
Considering partial fiidity at top & bottom, le = 0.8l
le
b

0.8 X 3000
350

= 6.857 < 12

So, it is a short column.


Check for P-M interaction:
32
2

d' = 40 + 8 +

= 64 mm

D = 450 mm
d'
b

64
350

= 0.18

Assume, pt = 4%

pt
f ck

4
25

= 0.16

d'
D

64
450

= 0.14

PU
f ck bd

3278.538 X 1000
25 X 350 X 450

= 0.83

From chart 45 of SP-16,

or,

M Ux

= 0.04

f ck b D

M Ux

= 0.04 25 350 4502 = 70.875 KN-m > 54.47 KN-m

Hence O.K.

From chart 46 of SP-16,

or,

M Uy

= 0.03

f ck D b

M Uy

= 0.03 25 450 3502 = 41.344 KN-m > 40.71 KN-m

Hence O.K.

From Cl. 39.6,


PUZ = 0.45 fck AC + 0.75 fy ASC = 0.45 250.96350450 + 0.754150.04350450 =
3661.875 KN
PU
PUZ

3278.538
3661.875

= 0.895

n = 2.0
M UX
M UX 1

( )

M UY
M UY 1

( )

54.47
70.875

40.71
41.344

= 1.06 1

O.K.
ASC = 0.04 X 350 X 450 = 6300 mm2
Let us provide 4 nos. 32 & 4 nos. 28 bars. [ASC provided = 6560 mm2]
Design of Lateral Tie:
Diameter of lateral ties should be maximum of the following:
a. X Greatest dia. of main bar = X 32 = 8 mm
b. 6 mm
Let us provide 8 mm links.

Hence

Pitch should be minimum of the following:


a. Least lateral dimension = 350 mm
b. 16 X Least dia of main bar = 16 X 28 = 448 mm
c. 300 mm
Let us provide 8 mm links @ 300 mm c/c

Design of Column at C (Corner Column)


Total axial load on the column = 296.406 6 = 1778.436 KN
MU = 122.49 KN-m
Size of column = 350 mm 450 mm
Check for Eccentricity:
[Cl 25.4]
e=

l
500

b
30

3000
500

450
30

= 21 mm > 20 mm

e = 21 mm

0.05D = 0.05 450 = 22.5 mm > e


Hence O.K.
Check for Slenderness Ratio:
Considering partial fixidity at top & bottom, le = 0.8l

le
b

0.8 X 3000
350

So, it is a short column.

= 6.857 < 12

Check for P-M interaction:


28
2

d' = 40 + 8 +

= 62 mm

D = 450 mm
d'
D

64
450

= 0.14

Assume, pt = 4%
pt
f ck

PU
f ck bd

2.5
25

= 0.10

1778.436 X 1000
25 X 350 X 450

= 0.45

From chart 45 of SP-16,

or,

M Ux
f ck b D2
M Ux

= 0.09

= 0.09 25 350 4502 = 159.469 KN-m > 122.49 KN-m Hence O.K.

ASC = 0.025 X 350 X 450 = 3937.5 mm2


Let us provide 8 nos. 28 bars. [ASC provided = 4928 mm2]
Design of Lateral Tie:
Diameter of lateral ties should be maximum of the following:
c. X Greatest dia. of main bar = X 28 = 7 mm
d. 6 mm
Let us provide 8 mm links.
Pitch should be minimum of the following:
d. Least lateral dimension = 350 mm
e. 16 X Least dia of main bar = 16 X 28 = 448 mm
f. 300 mm
Let us provide 8 mm links @ 300 mm c/c