Pneumatic Actuator 11 21 Datasheet English

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4
At a glance
Powered by AI
The document discusses pneumatic actuators and how they can be combined with ball valves. It provides details on the components, specifications, and operating modes of the actuators.

The main components of the pneumatic actuator are the housing, piston, rack, pinion, springs and connectors for control air.

The pneumatic actuator can operate in fail-safe close, fail-safe open and double acting modes depending on the solenoid valve used to control it.

Datasheet Pneumatic Actuator PA 11 / 21

Advantages
- Robust PP-GF housing
- Full plastic actuator
- Position indicator with integrated NAMUR interface
- Fast cycle times
- Multi functional modul with different limit switch types
optional available

Combinations
PA 11 with 2- Way Ball Valve Type 546 from d16DN10 to d32DN25
PA 21 with 2- Way Ball Valve Type 546 from d40DN32 to d63DN50
Nominal torque Mdn
Housing materials
10 Nm (7.4 lb. ft.)
PP fiberglass-reinforced, highly chemical resistant
Connectors
Peak torque
20 Nm (15 lb. ft.)
PA11: F04
Actuator connection
PA21: F05
G1/8"
Weight
0.75 kg - 1.445 kg
Control time
1 - 2 s, with throttle valve 5 s
Control volume in dm
DN
Mode of operation
Single acting
Double acting
Fail-safe close (FC)
mm
(FC/FO) dm
(DA) dm
Fail-safe open (FO)
10
Double acting (DA)
0.18 (open)
15
0.15
(closed)
Working principle
PA11
0.15
Rack and pinion
20
25
Temperature control medium
Max. 40 C
32
0.35 (open)
40
PA21
0.28
Ambient temperature
0.28 (closed)
-10 bis +50 C
50
Control medium
Accessories
Neutral, non aggressive gases
3/2-Way pilot solenoid valve PV94/95
(Control with fluids on request)
3/2 and 5/2-way pilot solenoid valve MNL532
Compressed air class per ISO 8573-1
4/2-way solenoid valve 5470
2 or 3 at -10 C
Namur connector plate
3 or 4 at T > 0 C
Pilot valve cluster PV2000
Allowable humidity
Electropneumatic positioner DSR500-3
0 - 100 %
Limit switch box for feedback
Max. allowable control pressure
AS-Interface connections
7 bar
Emergency manual override
Position indicator
Optical integrated

Combinations
Pneumatic actuated Ball Valves Type 230-235
Ball valves type 230 - 235 are based on manual ball valve type 546 d16DN10 to d63DN50 and
pneumatic actuator PA11 (DN10-DN25) or PA21 (DN32-DN50).
Ball Valve
Pneumatic
Type 230
Type 231
Type 232
Type 233
Type 234
Type 235

Pneumatic
Actuator
PA 11 / PA21
PA 11 / PA21
PA 11 / PA21
PA 11 / PA21
PA 11 / PA21
PA 11 / PA21

Manual Ball
Valve
Type 546
Type 546
Type 546
Type 546
Type 546
Type 546

Dimensions

DN 10 - DN 50
DN 10 - DN 50
DN 10 - DN 50
DN 10 - DN 50
DN 10 - DN 50
DN 10 - DN 50

Materials

Standards

PVC-U, PVC-C, ABS,


PP-H
PVDF
PVC-U, PVC-C,
PVC-U, ABS,
PVC-U, PVC-C, PP-H,
PVDF

ISO/DIN
all standards
all standards
ASTM/ANSI
BS
JIS

Ball valves type 285 - 288 are based on ball valve type 543 d16DN10 to d63DN50 and
pneumatic actuator PA21. The type range 285-288 is designed as modular upgradeable
3-Way ball valve for mixing and diverting applications which demand special process
requirements.
Ball Valve
Pneumatic

Pneumatic
Actuator

Type 285

PA 11 / PA 21

Type 286

PA 11 / PA 21

Type 287

PA 11 / PA 21

Type 288

PA 11 / PA 21

Manual Ball
Valve
Type 543
horizontal
Type 543
horizontal
Type 543
horizontal
Type 543
vertical

Dimensions

Materials

Standards

DN 10-DN 50

PVC-U,
PVC-C,
ABS

all standards

DN 10-DN 50

PROGEF

DIN/ISO, ASTM

DN 10-DN 50

SYGEF

DIN/ISO, ASTM

DN 10-DN 50

PVC-U,
ABS

DIN/ISO, JIS

Exploded view
1. Spring cover
2. Optical position indicator
3. Housing of PP-GF
4. Piston with rack

5. Pinion shaft
6. Preloaded spring assembly
7. Connection for control air G1/8

Dimensions

PA11
PA21

L1
mm
194
224

L2
mm
44
55

L3
mm
80
80

L4
mm
24
24

L5
mm
48
58.5

L6
mm
54
58

L7
mm
275
305

H1
mm
97
119

H2
mm
20
20

H3
mm
4
4

H4
mm
40
51

D1
mm
29
29

D2
mm
M5
M5

D3
mm
61
82

D4
mm
74
94

D5
G1/8"
G1/8"

D6
mm
35
35

torque characteristics
PA 11

PA 21

Operating Diagram FC, FO, DA

Fail safe to close (FC) with 3/2-Way Solenoid


Valve de-energized closed

Double acting (DA) with 5/2-Way Solenoid Valve

Fail safe to open (FO) with 3/2-Way Solenoid


Valve de-energized closed

Double acting (DA) with 4/2-Way Solenoid Valve

Planning Fundamentals
The following link will lead you to the Georg Fischer Planning Fundamentals. These detailed documents will
support you by choosing the right valve for your application.
http://www.gfps.com/content/gfps/com/en/support_and_services/planning_assistance/planning_fundamentals.html?lang=en

You might also like