FUNCTIONAL DATA:
Step-by-Step Operation:
Using both the radio control (CODE LED illuminated) and the
low voltage push-button station (PUL) to control the gate, the
following operation is obtained:
the first impulse opens the gate until the motor timer reaches
zero or until the opening stop limit is reached, the second
impulse closes the shutter; if an impulse arrives before the
opening stop limit is reached, the control unit stops motion
during both opening and closing. A futher command restarts
motion in the opposite direction.
Automatic closing:
The control unit can close the gate automatically without
sending additional commands.
The selection of this operation mode is described in the Pause
Time programming mode.
Pedestrian Passage:
If selected (PED CODE LED illuminated), using the pedestrian
radio control to control the gate, the following operation is
obtained: the first press is a command for the gate to open for
10 seconds, then the control unit pauses for 10 seconds and
the gate closes again.
Safety device:
The control unit enables power supply and connection for
photoelectric cells and pneumatic buffers (NC).
No action is taken into account during the opening stage and
causes inverted motor action during the closing stage.
If not used, this input must be bridged.
Initial pick-up and Motor Power Adjustment:
The electronic control unit is equipped with initial pick-up and
motor power adjustment functions that are fully managed by
the microprocessor.
The initial pick-up function is used to help the motor in its initial
activation stage, powering it at the maximum level for 2
seconds, even if the motor power adjustment function is
enabled.
The motor power adjustment function is used to ensure the
correct motion of the gate, blocking it in case of obstruction
without causing harm to individuals or their property.
Deceleration:
The motor deceleration function is used to avoid the gates
moving at high speed towards the end of the opening and
closing stages.
Deceleration can be programmed for the desired points (before
the gates are totally open or closed) during Motor Timer
programming.
Flashing Beacon Operation:
The control unit is equipped with output for a 230 V a/c flashing
beacon. The flashing beacon is only activated when the motor
is running.
Operation with TIMER:
The control unit may be connected to a timer instead of using
the open-close command button (PUL).
Example: at 8:00 a.m. the timer closes the contact and the
control unit opens the gate; at 6:00 p.m. the timer opens the
contact and the control unit closes the gate. Between 8:00 a.m.
and 6:00 p.m. at the end of the opening phase, the control unit
disables the flashing beacon, the automatic closing stage and
the radio controls.
PROGRAMMING:
SEL key: selects the type of function to be stored; selection is
indicated by a flashing LED.
By pressing the key repeatedly, you can select the desired
function.
The selection remains active for 10 seconds
(indicated by the flashing LED); after 10 seconds, the control
unit returns to its original status.
SET key: programmes the information according to the type of
function selected previously using the SEL key.
IMPORTANT: The function of the SET key can be replaced
with the radio control, if programmed previously (CODE LED
on).
MAIN MENU
The control unit is supplied by the manufacturer with the option
of selecting a number of principal functions.
---------------------- MAIN MENU ----------------LED Reference
1) CODE
2) CODE PED.
LED Off
No code
No code
LED On
Code inserted
Code inserted
3) INB.CMD.AP
Disabled
4) LAMP/CORT.
Flashing
5) T. MOT.
Programmed time 30 sec.
6) T. PAUSA.
No automatic closure
Enabled
Courtesy light
Programmed time
Automatic closure
EXTENDED MENU 1
The control unit is supplied by the manufacturer with only the
option of directly selecting the functions listed in the main
menu.
To enable the functions listed in extended menu 1, proceed as
follows: press the SET button and hold for 5 seconds; the T.
MOT. and T. PAUSA LEDs will flash alternately and the user
has 30 seconds within which to select the functions of
extended menu 1 using the SEL and SET buttons. When this
time has elapsed the control unit returns to the main menu.
---------------------- EXTENDED MENU 1 ----------------LED Reference
LED Off
LED On
A) CODE
Remote PGM = OFF
Remote PGM = ON
B) CODE PED.
Step-by-Step
Automatic Operation
C) INB.CMD.A
Pressure Maintenance = OFF
Press. Mainten. =
ON
D) LAMP/CORT
Electronic Brake= OFF
Electronic Brake =
ON
E) T. MOT.
Flashing beacon ON/OFF
F) T. PAUSA.
Flashing beacon ON/OFF
A) CODE
(Remote programming of radio control):
The control unit allows the transmission code to be
programmed by remote, without using the SEL key.
To programme the transmission code from remote proceed as
follows: send the radio control code continuously for more than
10 seconds and the control unit will enter the programming
mode as described above for the CODE LED in the main
menu.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with only the
option of directly selecting the functions listed in the main
menu.
To enable the functions listed in extended menu 2, proceed as
follows: access extended menu 1 (as described in the relevant
paragraph), then press the SET button again and hold for 5
seconds; the T. MOT. and T. PAUSA LEDs will flash
simultaneously and the user has 30 seconds within which to
select the functions of extended menu 2 using the SEL and
SET buttons. When this time has elapsed the control unit
returns to the main menu.
EXTENDED MENU 2
LED status
A) CODE
3) PED. CODE
C) INB.CMD.AP
D) LAMP/CORT
E) T. MOT.
LED off
LED on
1 sec. inversion time
0.5 sec. inversion time
Soft Start = OFF
Soft Start = ON
User present CH = OFF
User present CH = ON
Input PUL = PUL
Input PUL = D.S.
Simultaneous flashing beacon ON/OFF
F) T. PAUSA.
In
compliance
with
section
5.4.3
of
EN
12453,
Warning
All operations which require the casing to be opened (such as
wire connection, programming, etc.) must be carried out during
installation, by skilled staff only.
For any other procedure which requires the casing to be
opened again (programming, repairs or site modifications),
please contact the technical assistance service.