Safety Tips Escalator Travelator
Safety Tips Escalator Travelator
Safety Tips Escalator Travelator
Wedge guards shall be provided under the floor ceiling at the point crossing with the
escalators / travelators (including the soffit panel of the adjacent escalators /
travelators) to prevent anymore or anything from catching in the wedges.
If there is an opening between the escalators / travelators and the building floor, a
partition plate or a guard shall be placed to prevent a fall.
Auxiliary Brake
It will be actuated when the drive chain is broken or over speed.
Handrail Speed Monitor
When one or both handrails are broken or run under speed, the safety will be executed.
Missing Step / Pallet Device
Stops the escalator before missing portion entering comb plate in case of step missing.
Step Up thrust Contact
Stops the escalator in case of step up thrust.
Skirting Brush
To cover the gap between step and skirt panel in order to avoid possible risk caused by the
gap.
Under-step Lighting
The individual steps/pallets are clearly discernible and distinguishable.
Step Obstruction Device
Stops the escalator if the step is obstructed anywhere along its path of descent.
Comb Lighting
Highlights the start and finish of the moving steps/pallet.
Automatic Announcement System
Gives announcement or warning to passengers automatically.