CWT5010 User's Manual: Arameter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

1

CWT5010 Users manual

CONTENTS
V3.0

PREFACE............................................................................................................................................ 3

INTRODUCTION................................................................................................................................. 4
2.1

PARAMETER................................................................................................................................... 4

INSTALL.............................................................................................................................................. 5
3.1

SIZE ............................................................................................................................................... 5

3.2

LED INDICATOR DESCRIPTION ........................................................................................................ 5

3.3

TERMINAL DESCRIPTION................................................................................................................. 6

SETUP PARAMETERS FOR RTU ..................................................................................................... 7


4.1

ACCESS SETUP MODE .................................................................................................................... 7

4.2

SETUP BASIC PARAMETERS ............................................................................................................ 8

4.2.1 Setup CS number .................................................................................................................. 8


4.2.2 Setup basic parameters ........................................................................................................... 8
4.2.3 Alarm parameters..................................................................................................................... 9
4.2.4 ALL SMS .................................................................................................................................11
4.2.5 System Prio .............................................................................................................................11
4.3

INPUT AND OUTPUT ...................................................................................................................... 13

4.3.1 Setup input and output types ................................................................................................. 13


4.3.2 Define alarm and recover sms of digital input........................................................................ 15
4.3.3 Setup inputs timeouts............................................................................................................. 15
4.3.4 Setup digital inputs/outputs port name................................................................................... 16
4.3.5 CSs DIN authority.................................................................................................................. 17
4.4

SETUP I-SENSORS........................................................................................................................ 18

4.4.1 Buzzer .................................................................................................................................... 18


4.4.2 Tmp100 sensor (optional) ...................................................................................................... 18
4.4.3 Internal battery (optional) ....................................................................................................... 19
4.5

SETUP EXTEND TEMPERATURE SENSOR ........................................................................................ 20

4.5.1 Setup extend temperature...................................................................................................... 20


4.6

OTHERS SETTING......................................................................................................................... 21

4.6.1 Realtime Interlock................................................................................................................... 21


4.6.2 Timers..................................................................................................................................... 22
4.6.3 Weekly timers ......................................................................................................................... 23
4.6.4 Define users commands ........................................................................................................ 23

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

CWT5010 Users manual

1 PREFACE

2 INTRODUCTION

Thank you for using the CWT5010 GSM RTU. You will know well about the functions and operation
methods of this product quickly through this Users Manual.
This product is mainly used for remote alarming and control application based on GSM network. Please
use it according to the parameters and technical specifications in the Users Manual. Meanwhile, the
Notes shall be considered for the usage of radio-control products, especially GSM products. Our
Company bears no liability for property loss or bodily injury arising from abnormal or incorrect usage of

CWT5010 GSM RTU is designed as a cost effective remote control system alert device. It monitors
up to 4 dry contacts and 4 drivable relay outputs. User-defined SMS is sent to pre-configure mobile
phone numbers when a pre-defined alarm condition happens. These pre-configured mobile phone
numbers can belong to technicians or engineers who are responsible in handling corresponding alarms.
With the aid of this GSM RTU, the alarm condition brings attention to in-charge personnel immediately.

this product.

Besides it allows those mobile phone users to trigger any relay output by using SMS. The output can be
connected with alarm indication device, such as alarm, and others.

Package list

There is a built-in microprocessor chip running on a real-time operating system. It gives immediate
response to any change in both inputs and outputs condition. A GSM modem is embedded in the GSM

product

quantity

CWT5010 GSM RTU

1pcs

RS232 cable

1pcs

12V Adaptor

1pcs

GSM antenna

1pcs

CD

1pcs

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

RTU, user has to subscribe a SIM card for the GSM RTU. The GSM RTU can be installed in any location
under GSM coverage.

2.1 Parameter
Parameter item

Reference scope

DC Power supply

12-24V DC (Standard adapter: DC 12V/1.5A)

Power consumption

12V input Max. 150mA/Average 50mA

Frequency range

Quad-frequency 900/1800/850/1900HMz

SIM Card

Supporting 3V SIM Card

Antenna

50 SMA Antenna interface

Serial

RS232

Temperature range

-30C ~ +70 C

Humidity range

Relative humidity 95%

Digital Input

4 digital inputs(Dry contact)

output

4 drivable relay outputs(open-collector outputs)

Output drive voltage

Equal to input DC voltage

Output drive power

Drive voltage 35V, drive current 500mA

Exterior dimension

956325mm

Weight

256 g

www.mobq2000.com

CWT5010 Users manual

3.3 Terminal Description

3 INSTALL

3.1 size

. DC9-28V (power in)


DC

positive terminal of the DC power supply (+)

GND

Negative terminal of the DC power supply (- )

Warning must be careful that the polarity is not reversed, otherwise, the output will be damaged
. RS232

3.2 LED indicator description

RXD

Receive Data

Connect RS232 cable orange wire

TXD

Transmit Data

Connect RS232 cable blue wire

GND

Ground

Connect RS232 cable black wire

. 4 drivable relay output

Status

Indication description

DO0DO3

negative pole of relay coil

Normally light

Indicator for power supply, which will be light on when the system

DC

Positive pole of relay coil

on

is power on

Flicker

SMS module signal indicator, which will flicker slowly after the
system is registered in GSM network

Light on during

It will be light on when the system sends sms and light off when

handling

the handling is over

ACT (Orange)

Flicker

It will flicker periodically when the system is under operation, and


the interval time is 6 sec

Side led (green)

Light on or off

Light on during the internal battery is charge up

Indicator
PWR (Red)
NET (Green)
SRV (Yellow)

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

. 4 digital inputs (NO or NC)


DI0DI3

Connect NO or NC

GND

Connect COM

www.mobq2000.com

CWT5010 Users manual

4 SETUP PARAMETERS FOR RTU


4.1 Access setup mode

4.2
4.2.1

Setup basic parameters


Setup CS number

RTU under working mode, the CS number can send sms commands to control RTU and receive sms
Connect RTU and computer with RS232 cable, and open the configuration software, make RTU access
setup mode according to the following figure.

(include alarm sms, report sms etc). User can set 10 CS numbers, CS0-CS9

Note: Please choose the serial port No. and rate correctly, the default communication rate is 9600;
default password is 000000

4.2.2

Setup basic parameters

Definition: Working mode and setup mode


In setup mode, all functions are disabled, only to setup parameters. And RTU must be restart to enter
working mode, all functions is enabled, the RTU can alarm and be control.
NOTE
Access setup mode, the simcard and antenna is no need, but access wording mode, the simcard and
antenna is necessary.
How to know current mode:
Method 1: Check the ACT light, if the ACT light flickers twice per second, that means it is under the setup
mode; the flicker period of the ACT light can be up to 6 sec under the working mode.

Attention: gsm band, com bps, uart, pin code, country code please using the default parameter

Method 2: Check the information from the serial port, if the character string of dtu come in setup mode
occurs, it means that RTU is under the setup mode.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

Alarm for GSM signal low


GSM signal normal range is 18-32RTU sends alarm sms to CS number when RTUs GSM signal value

www.mobq2000.com

CWT5010 Users manual

below the preset threshold, the default is 11.


Daily report
enable the option, RTU will send a report sms to CS number at 10:00 every morning for reporting current
states, through which the user can make sure the normal operation of RTU.
Proof time
Proof time is keeping the RTUs os (operation system) has correct time. RTU can execute daily report,
timing arm or disarm, timing output at correct time.
Send proof time sms to cs when power up
When RTU power up, it send a sms to CS0 to request proof time, CS0 can reply sms999 to RTU to
complete proof time.
Send proof time sms to sp when power up
SP phone number is a phone that cans automatic reply a SMS to any incoming SMS, RTU use it to
update interior Clocker by the timestamp in SMS, the SMS contents is not important.
Device description
You can add description with RTU (such as install position, user information), the description is show in
RTU alarm sms.
Device ID
The device ID is an 8-byte ASCII characters which is show in RTU state sms.
4.2.3

auto answer call of service phone numbers


Attention: This option is valid for the RTU models that have audio interface.

If MIC and speaker are connected; RTU auto answer when CS numbers call it, so user can remote
monitor voice and speaking.
Auto add basic description with alert sms
Enable this option, the description (such as install position, user information) that have been defined by
user will show in alarm sms and daily report sms.
print RTU alarm events by com port
Enable this option, when RTU alarm, it sends the alarm data to com port with CWT_IO data format.
delay send sms time when alarm(disarm delay)
Define the time; you have an enough time to disarm RTU when you go into the monitor area.
Holding time after arm(arm delay time)
Define the time; you have an enough time to arm RTU when you leave the monitor area.
Extend information with report
RTU can send report sms to cs phones by timer or users inquiry by sms command, this function is
designed to let user know the RTU is stilling working and its status, enable or disable follow information
to show in report.

Alarm parameters

Interior temperature: The internal temperature sensor is optional, if RTU has added it, the
temperature value will show in the daily report.
AttentionA standard RTU have not internal temperature sensor
Device Id: enable this option, ID will show in the daily report.
Arm status: enable this option, arm or disarm status will show in the daily report.
Signal of gsm network: enable this option, GSM signal value will show in the daily report.
Devices memo: enable this option, Device description will show in the daily report.
Power supply status: enable this option, the daily report will show power supply status
Ex-temperature:
Attention: This option is valid for the RTU models that have temperature inputs (DS18B20 inputs).
Enable this option, all the value of extend temperature sensor will show in the daily report.
Alarm inputs: enable this option, the inputs that are in alarm status will show in the daily report.
ring when alert
Enable this option, RTU will give CS number a phone call then send sms when alarm

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

AD0~AD3: enable those options, all the value of AD input will show in the daily report.

www.mobq2000.com

10

11

CWT5010 Users manual

4.2.4

ALL SMS

In this page, you can see all sms contents that you have defined, include digital inputs alarm/recover
sms, AD inputs alarm/recover sms etc. you can Double-click it to modify.
4.2.5

Authority

Explanation

admin

Can Arm/disarm or not

Modify by sms

This CS number can be modify by sms command or not

Change cs phones

This CS number can modify other CS number by sms command or not

Powerup sms

Can receive the status sms or not when RTU is restarted by sms command

Daily report sms

Can receive the daily report or not

Timer mms

Null

Alarm mms

Null

I-tmp alarm sms

Can receive the alarm sms or not when internal temperature sensor alarm

I-tmp alarm ring

Can receive the alarm phone call or not when internal temperature sensor alarm

Power fail sms

Can receive the alarm sms of power failure or not

Power fail ring

Can receive the alarm phone call of power failure or not

Signal low alarm

Null

Sample sms

Null

M2M svr

RTU send sms to the CS number with CWT_IO protocol

Arm notify

Can receive sms when RTU arm or disarm

System Prio

In this page, you can set authorization for CS numbers


O means enable authorization; X means disable authorization.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

12

13

CWT5010 Users manual

4.3

Input and Output

4.3.1

Setup input and output types

Sound
Means this channel input alarm event can cause internal buzzer and extend buzzer or siren action.
Use digital input 1 as arm control
Enable this option, RTU is in arm mode if digital input 1 is opened, RTU is in disarm mode if digital input
1 is closed, so user can connect a button to switch mode for arm or disarm
ATTENTION: Use digital input1 as arm control you need select the type of input1 is TO CLOSE
ALARM (LEVEL) and delete the alarm/recover sms of input 1
Counter
Enable or disable this channel input as counter input which catch greater than 100ms plus.
Counter upload timer
Setup the counter GPRS upload interval

Counter upload only changed data


Automatic counter upload mode is a mode to Save GPRS, not report data if value not changed.
Attention: This option is valid for the RTU models that have GPRS function.
Digital inputs types
Input signals have two types, EDGE_IN (edge triggering) and LEVEL_IN (state triggering).
ATTENTION: The key deference between Level and Edge is Level input has recovery sms message
and Level input can repeat alarm status sms notify by an interval.

Output types
0

disable

relay drivable output

Drive relay, drive electricity <0.2A


Output drive relay voltage Equal to input DC voltage
Output power: Drive voltage 35V, drive current 200mA

Level input alarm

Buzzer

This lines actions will synchronize with internal buzzer.

SNAPSHOOT

This line wills shortly action when any alarm happens.

SIREN

This line continuous drives for 1 minute by default. And the


interval can be user define.

Typical edge alarm

Remember outputs status


RTUs outputs default status is open; it is possible closed during working. After restart, the outputs will be
reset, status is open. If enable the option, output can recover the status that before restart.

24 Hours

If enable this option, the digital input will execute alarm action (send alarm sms, interlock etc) when it is
triggered, even RTU is in disarm status.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

14

15

CWT5010 Users manual

4.3.2

Define alarm and recover sms of digital input

3. Alarms ensure timeouts


It is a counter of alarm status ensure timer, designed to avoid shake mistakes. 0 means no counter.

All of the input lines sms can be modify. A SMS composed of not more than 60 characters
4.3.3

Setup inputs timeouts


4.3.4

Setup digital inputs/outputs port name

This page designed to setup input timeouts property. There are 3 interval related with inputs.
1. Alarm sms limit interval
It is designed to avoid amounts of alarm/recover sms in a short time.

If you send sms command to require inputs status, there is a contrast of returning
from+8613480165874
High voltagenormal

Input 0 normal

Low voltagealarm

Input 1 alarm

High water levelnormal

Input 2 normal

Low water levelnormal

Input 3 normal

Have setup input name


2. Alarm sms resend interval
It is designed for repeat alarm status notifies to phones, 0 means disable repeat notification.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

from+8613480165874

Have not setup input name

Setup outputs name is same

www.mobq2000.com

16

17

CWT5010 Users manual

4.3.5

CSs DIN authority

4.4

Setup I-sensors

This page can setup the authority of CS phone receive digital input alarm sms and alarm call
O means this cs phone will receive related line in sms, X means not.

4.4.1

Buzzer

Attention: This setting is valid for the RTU models that have buzzer.
The buzzer can be activated when alarm.
In this page, you can enable or disable the buzzer and set interval time of alarm

Example:
4.4.2

Tmp100 sensor (optional)

Attention: This setting is valid for the RTU models that are added interior temperature sensor, the
tmp100 temperature is optional, a standard RTU have not internal temperature sensor.

This settings means CS0 dont receive input 0 alarm


CS1 dont receive input1 alarm sms.
CS3 dont receive input0 alarm sms.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

18

19

CWT5010 Users manual

You can preset a high and a low temperature value, if temperature is over normal range, RTU alarm. You
also can send sms command to RTU to get current temperature.
User can set Adjust value to calibrating temperature value
Timespan of twice alarm sms
It is designed to avoid amounts of alarm/recover sms in a short time.
TMPRS time: timespan of resend alarm sms
It is designed for repeat alarm status notifies to phones, 0 means disable repeat notification.
time of ensure alarm
It is a counter of alarm status ensure timer, designed to avoid shake mistakes. 0 means no counter.
4.4.3

4.5
4.5.1

Setup extend temperature sensor


Setup extend temperature

CWT5016 can connect 4 extend wired temperature sensors DS18B20.


You can preset a high and a low level for every channel, if the current temperature is above the high level
or below the low level, CWT5016 alarm. You can also send sms command to get current temperature.
DS18B20 temperature probes
temperature range: -55~+125; precision0.5

Internal battery (optional)

Attention: This setting is valid for the RTU models that are internal battery.
It is designed to realize power lost alarm
When external power cut off, RTU Powered by internal battery and alarm to cs numbers

Adjustments
You can set the value to reduce error.
time of ensure power alarm
When the time of external power lost is over the time, RTU alarm, 0 means disable the function.
Battery parameter:
Lithium battery
Voltage: 3.7V
Capacity: 800mAh
Limited voltage for charging 4.2V
Implementation standard GB/T 18287-2000

Alarm sms interval


The time is designed to avoid amounts of alarm/recover sms in a short time.
Re-alarm sms interval
Designed for repeat alarm status notifies to phones, 0 means disable repeat notification.
Alarm ensuring timer
It is a counter of alarm status ensure timer, designed to avoid shake mistakes. 0 means no counter.
24 Hours property
If checked, the channel will execute alarm action (send alarm sms, interlock etc) when it is triggered,
even CWT5016 is in disarm status.
Sound property
Means this line alarm event will cause internal buzzer and extend buzzer or siren action.
Enable property
Enable or disable this channels alarm

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

20

21

CWT5010 Users manual

4.6
4.6.1

Others setting

4.6.2

Timers

Realtime Interlock

Timers is designed to time execute task, task include arm, disarm, open/close output etc.

Realtime interlock is a local strategy, it is designed to outputs automatically execute action under some
internal triggering conditions.

Minutes timers
4 minute counters can be set, RTU execute a task every the minute interval.
For example, RTU execute output 0 pulse every 30 minutes

For example
If digital input 0 alert, output 0 close pulse 5 seconds.

Second timers
4 second counters can be set, RTU execute a task every the second interval.
System timers
6 times can be set in a day, RTU execute a task in each time.
For example, at 8:30 execute output 0 on, at 17:00 execute output 0 off.

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954

www.mobq2000.com

22

23

4.6.3

Weekly timers

7 times can be set in a week, RTU execute a task in each time.


For example, execute send daily report at Monday 10:30 RTU
4.6.4

Define users commands

Users can define 6 commands instead of system commands.


For example, user set close instead of system command IOOH, so user can send close to close
output

SHEN ZHEN YIKEHUDONG TECHNOLOGY TRADE LTD TEL+86-755-26719954