CWT5010 User's Manual: Arameter
CWT5010 User's Manual: Arameter
CWT5010 User's Manual: Arameter
CONTENTS
V3.0
PREFACE............................................................................................................................................ 3
INTRODUCTION................................................................................................................................. 4
2.1
PARAMETER................................................................................................................................... 4
INSTALL.............................................................................................................................................. 5
3.1
SIZE ............................................................................................................................................... 5
3.2
3.3
TERMINAL DESCRIPTION................................................................................................................. 6
4.2
SETUP I-SENSORS........................................................................................................................ 18
OTHERS SETTING......................................................................................................................... 21
www.mobq2000.com
1 PREFACE
2 INTRODUCTION
Thank you for using the CWT5010 GSM RTU. You will know well about the functions and operation
methods of this product quickly through this Users Manual.
This product is mainly used for remote alarming and control application based on GSM network. Please
use it according to the parameters and technical specifications in the Users Manual. Meanwhile, the
Notes shall be considered for the usage of radio-control products, especially GSM products. Our
Company bears no liability for property loss or bodily injury arising from abnormal or incorrect usage of
CWT5010 GSM RTU is designed as a cost effective remote control system alert device. It monitors
up to 4 dry contacts and 4 drivable relay outputs. User-defined SMS is sent to pre-configure mobile
phone numbers when a pre-defined alarm condition happens. These pre-configured mobile phone
numbers can belong to technicians or engineers who are responsible in handling corresponding alarms.
With the aid of this GSM RTU, the alarm condition brings attention to in-charge personnel immediately.
this product.
Besides it allows those mobile phone users to trigger any relay output by using SMS. The output can be
connected with alarm indication device, such as alarm, and others.
Package list
There is a built-in microprocessor chip running on a real-time operating system. It gives immediate
response to any change in both inputs and outputs condition. A GSM modem is embedded in the GSM
product
quantity
1pcs
RS232 cable
1pcs
12V Adaptor
1pcs
GSM antenna
1pcs
CD
1pcs
RTU, user has to subscribe a SIM card for the GSM RTU. The GSM RTU can be installed in any location
under GSM coverage.
2.1 Parameter
Parameter item
Reference scope
DC Power supply
Power consumption
Frequency range
Quad-frequency 900/1800/850/1900HMz
SIM Card
Antenna
Serial
RS232
Temperature range
-30C ~ +70 C
Humidity range
Digital Input
output
Exterior dimension
956325mm
Weight
256 g
www.mobq2000.com
3 INSTALL
3.1 size
GND
Warning must be careful that the polarity is not reversed, otherwise, the output will be damaged
. RS232
RXD
Receive Data
TXD
Transmit Data
GND
Ground
Status
Indication description
DO0DO3
Normally light
Indicator for power supply, which will be light on when the system
DC
on
is power on
Flicker
SMS module signal indicator, which will flicker slowly after the
system is registered in GSM network
Light on during
It will be light on when the system sends sms and light off when
handling
ACT (Orange)
Flicker
Light on or off
Indicator
PWR (Red)
NET (Green)
SRV (Yellow)
Connect NO or NC
GND
Connect COM
www.mobq2000.com
4.2
4.2.1
RTU under working mode, the CS number can send sms commands to control RTU and receive sms
Connect RTU and computer with RS232 cable, and open the configuration software, make RTU access
setup mode according to the following figure.
(include alarm sms, report sms etc). User can set 10 CS numbers, CS0-CS9
Note: Please choose the serial port No. and rate correctly, the default communication rate is 9600;
default password is 000000
4.2.2
Attention: gsm band, com bps, uart, pin code, country code please using the default parameter
Method 2: Check the information from the serial port, if the character string of dtu come in setup mode
occurs, it means that RTU is under the setup mode.
www.mobq2000.com
If MIC and speaker are connected; RTU auto answer when CS numbers call it, so user can remote
monitor voice and speaking.
Auto add basic description with alert sms
Enable this option, the description (such as install position, user information) that have been defined by
user will show in alarm sms and daily report sms.
print RTU alarm events by com port
Enable this option, when RTU alarm, it sends the alarm data to com port with CWT_IO data format.
delay send sms time when alarm(disarm delay)
Define the time; you have an enough time to disarm RTU when you go into the monitor area.
Holding time after arm(arm delay time)
Define the time; you have an enough time to arm RTU when you leave the monitor area.
Extend information with report
RTU can send report sms to cs phones by timer or users inquiry by sms command, this function is
designed to let user know the RTU is stilling working and its status, enable or disable follow information
to show in report.
Alarm parameters
Interior temperature: The internal temperature sensor is optional, if RTU has added it, the
temperature value will show in the daily report.
AttentionA standard RTU have not internal temperature sensor
Device Id: enable this option, ID will show in the daily report.
Arm status: enable this option, arm or disarm status will show in the daily report.
Signal of gsm network: enable this option, GSM signal value will show in the daily report.
Devices memo: enable this option, Device description will show in the daily report.
Power supply status: enable this option, the daily report will show power supply status
Ex-temperature:
Attention: This option is valid for the RTU models that have temperature inputs (DS18B20 inputs).
Enable this option, all the value of extend temperature sensor will show in the daily report.
Alarm inputs: enable this option, the inputs that are in alarm status will show in the daily report.
ring when alert
Enable this option, RTU will give CS number a phone call then send sms when alarm
AD0~AD3: enable those options, all the value of AD input will show in the daily report.
www.mobq2000.com
10
11
4.2.4
ALL SMS
In this page, you can see all sms contents that you have defined, include digital inputs alarm/recover
sms, AD inputs alarm/recover sms etc. you can Double-click it to modify.
4.2.5
Authority
Explanation
admin
Modify by sms
Change cs phones
Powerup sms
Can receive the status sms or not when RTU is restarted by sms command
Timer mms
Null
Alarm mms
Null
Can receive the alarm sms or not when internal temperature sensor alarm
Can receive the alarm phone call or not when internal temperature sensor alarm
Null
Sample sms
Null
M2M svr
Arm notify
System Prio
www.mobq2000.com
12
13
4.3
4.3.1
Sound
Means this channel input alarm event can cause internal buzzer and extend buzzer or siren action.
Use digital input 1 as arm control
Enable this option, RTU is in arm mode if digital input 1 is opened, RTU is in disarm mode if digital input
1 is closed, so user can connect a button to switch mode for arm or disarm
ATTENTION: Use digital input1 as arm control you need select the type of input1 is TO CLOSE
ALARM (LEVEL) and delete the alarm/recover sms of input 1
Counter
Enable or disable this channel input as counter input which catch greater than 100ms plus.
Counter upload timer
Setup the counter GPRS upload interval
Output types
0
disable
Buzzer
SNAPSHOOT
SIREN
24 Hours
If enable this option, the digital input will execute alarm action (send alarm sms, interlock etc) when it is
triggered, even RTU is in disarm status.
www.mobq2000.com
14
15
4.3.2
All of the input lines sms can be modify. A SMS composed of not more than 60 characters
4.3.3
This page designed to setup input timeouts property. There are 3 interval related with inputs.
1. Alarm sms limit interval
It is designed to avoid amounts of alarm/recover sms in a short time.
If you send sms command to require inputs status, there is a contrast of returning
from+8613480165874
High voltagenormal
Input 0 normal
Low voltagealarm
Input 1 alarm
Input 2 normal
Input 3 normal
from+8613480165874
www.mobq2000.com
16
17
4.3.5
4.4
Setup I-sensors
This page can setup the authority of CS phone receive digital input alarm sms and alarm call
O means this cs phone will receive related line in sms, X means not.
4.4.1
Buzzer
Attention: This setting is valid for the RTU models that have buzzer.
The buzzer can be activated when alarm.
In this page, you can enable or disable the buzzer and set interval time of alarm
Example:
4.4.2
Attention: This setting is valid for the RTU models that are added interior temperature sensor, the
tmp100 temperature is optional, a standard RTU have not internal temperature sensor.
www.mobq2000.com
18
19
You can preset a high and a low temperature value, if temperature is over normal range, RTU alarm. You
also can send sms command to RTU to get current temperature.
User can set Adjust value to calibrating temperature value
Timespan of twice alarm sms
It is designed to avoid amounts of alarm/recover sms in a short time.
TMPRS time: timespan of resend alarm sms
It is designed for repeat alarm status notifies to phones, 0 means disable repeat notification.
time of ensure alarm
It is a counter of alarm status ensure timer, designed to avoid shake mistakes. 0 means no counter.
4.4.3
4.5
4.5.1
Attention: This setting is valid for the RTU models that are internal battery.
It is designed to realize power lost alarm
When external power cut off, RTU Powered by internal battery and alarm to cs numbers
Adjustments
You can set the value to reduce error.
time of ensure power alarm
When the time of external power lost is over the time, RTU alarm, 0 means disable the function.
Battery parameter:
Lithium battery
Voltage: 3.7V
Capacity: 800mAh
Limited voltage for charging 4.2V
Implementation standard GB/T 18287-2000
www.mobq2000.com
20
21
4.6
4.6.1
Others setting
4.6.2
Timers
Realtime Interlock
Timers is designed to time execute task, task include arm, disarm, open/close output etc.
Realtime interlock is a local strategy, it is designed to outputs automatically execute action under some
internal triggering conditions.
Minutes timers
4 minute counters can be set, RTU execute a task every the minute interval.
For example, RTU execute output 0 pulse every 30 minutes
For example
If digital input 0 alert, output 0 close pulse 5 seconds.
Second timers
4 second counters can be set, RTU execute a task every the second interval.
System timers
6 times can be set in a day, RTU execute a task in each time.
For example, at 8:30 execute output 0 on, at 17:00 execute output 0 off.
www.mobq2000.com
22
23
4.6.3