P142 OrderForm

This document provides information about a MiCOM P142 feeder management device, including its specifications, options, and order form. Key details include available hardware and software options, nominal voltage ratings, mounting options, languages, and customization levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views11 pages

P142 OrderForm

This document provides information about a MiCOM P142 feeder management device, including its specifications, options, and order form. Key details include available hardware and software options, nominal voltage ratings, mounting options, languages, and customization levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 11

Our policy is one of continuous development. Accordingly the design of our products may change at any time.

Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is
intended for information purposes only.
Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot
be held responsible for any reliance on any decisions taken on its contents without specific advice.

Order form

MiCOM P142
Ready-to-use configuration

Feeder Management

P142

M **

Design Suffix
CPU3
Grey/Grey case, dual characteristic opto inputs, IEC61850, InterMICOM

L
J

Vx Auxiliary Rating
24 - 32Vdc
48 - 110Vdc
110 - 250Vdc (100 - 240Vac)

9
2
3

In/Vn Rating
In = 1/5A, Vn = 100 - 120Vac
In = 1/5A, Vn = 380 - 480Vac (Min 196Vac Max 560Vac)

1
2

Hardware Options
Standard - None
IRIG-B Only (Modulated)
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3)
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3)
+ IRIG-B modulated
Ethernet (10 Mbps)
Ethernet (100 Mbps)
Courier Rear Port
IRIG-B (Modulated) & Courier Rear Port
Ethernet (100Mbit/s) plus IRIG-B (Modulated)
Ethernet (100Mbit/s) plus IRIG-B (De-modulated)
InterMiCOM + Courier Rear Port
InterMiCOM + Courier Rear Port + IRIG-B modulated
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Un-modulated IRIG-B
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Un-modulated IRIG-B
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Un-modulated IRIG-B
Redundant Ethernet Parallel Redundancy Protocol (PRP), 2 multimode fibre ports + Modulated IRIG-B
Redundant Ethernet Parallel Redundancy Protocol (PRP), 2 multimode fibre ports + Un-modulated IRIG-B

Protocol Compatibility
1, 2, 3 & 4
1, 2, 3 & 4
3
1, 2 & 4
3
1, 2 & 4
5
5, 6, 7 & 8
1, 2, 3 & 4
1, 2, 3 & 4
6, 7 & 8
6, 7 & 8
1, 2, 3 & 4
1, 2, 3 & 4
6, 7 & 8
6, 7 & 8
6, 7 & 8
6, 7 & 8
6, 7 & 8
6, 7 & 8
6, 7 & 8
6, 7 & 8

Product Specific Option


8 logic inputs & 7 relay outputs
12 logic inputs & 11 relay outputs
16 logic inputs & 7 relay outputs
8 logic inputs & 15 relay outputs
8 logic inputs & 11 relay outputs (including 4 High Break)
Protocol / Communications Options
K-Bus
Modbus
IEC 60870-5-103 (VDEW)
DNP3.0
UCA2
IEC 61850 over Ethernet and Courier via rear K-Bus/RS485
IEC61850 over ethernet with CS103 rear port RS485 protocol
DNP3 over Ethernet with Courier rear port K-Bus/RS485 protocol
IEC61850 over Ethernet with DNP3.0 rear port RS485 protocol

1
2
3
4
5
6
7
8
A
B
E
F
G
H
J
K
L
M
N
P

A
B
C
D
H
Hardware Compatibility
1,2,3,4,7,8,C,E & F
1,2,3,4,7,8,C,E & F
1,2,3,4,7,8,C,E & F
1,2,3,4,7,8,C,E & F
5&6
6, A, B, G, H , J, K, L, M, N or P
6, A, B, G, H , J, K, L, M, N or P
6, A, B, G, H , J, K, L, M, N or P
6, A, B, G, H , J, K, L, M, N or P

1
2
3
4
5
6
7
8
9

* NB: UCA2 option is not available with software versions 32, and later
Mounting Option
Flush Panel Mounting,
Multilingual Language Option
English, French, German, Spanish
English, French, German, Russian
Chinese, English or French via HMI, with English or French only via Communications port
Software Issue
Customisation
Default
Customer specific

12/27/2014

0
5
C
**

8
9

MiCOM P142

Order form configurator

Ready-to-use configuration
1-4

Feeder Management with autoreclose


SAP PART NUMBER

14

15

P142 9 1 1 A 1 M 0 A0 8
E142911A1M0A08L

Design Suffix

L
Software

A0

Vx Aux Rating

9
In/Vn Rating

1
Hardware Options

Product Specific Options

A
Protocol/Communications Options

1
Mounting Option

Flush Panel Mounting

Language

0
Customisation

12/27/2014

10

11

12-13

Master Text

P142911A1M0A08L
Feeder Management with autoreclose
Vx Nominal auxiliary voltage options :
24 - 32Vdc
In/Vn Rating options :
In = 1/5A, Vn = 100-120Vac
Hardware options :
Standard - None
Product specific options :
8 logic inputs & 7 relay outputs
Protocol options :
K-Bus
Mounting options :
Flush Panel Mounting,
Language options :
Multilingual - English, French, German, Spanish
Software options :
A0
Customisation :
Default

ATEX II (2) G

Page 4 of 11

255733680.xls.ms_office

12/27/2014

27/11/14
09/07/14
04/02/14
25/06/13
20/11/12
01/10/12
11/09/12
21/08/12
09/08/12
09/07/12
02/06/12
08/05/12
10/03/12
13/02/12
06/02/12
13/09/11
10/08/11
20/02/11
07/10/10
04/10/10
18/08/10
10/06/10
05/05/10
10/02/10
29/01/10
02/12/09
08/05/09
04/03/09
01/12/08
27/08/08
12/08/08
01/07/08
06/05/08
18/03/08
06/03/08
12/04/07
10/02/07
08/01/07
12/09/06
05/08/06
09/06/06
01/06/06
17/05/06
28/03/06
21/03/06
26/10/05
10/10/05
21/03/05
14/02/05
02/02/05
20/12/04
06/12/04
23/11/04

12/10/04
23/06/04
04/05/04
03/05/04
11/03/04
18/02/04
19/01/04
17/11/03
13/09/03
19/05/03
08/05/03
24/03/03
18/02/03
07/11/02
15/08/02
01/06/02
30/11/01
30/11/01
30/11/01

As per NALW-9Q3DKQ - P140VA0A Major Software Release


As per SBIA-9KBCL4 new power supply option released (9) with (1) removed from option
As per DKEG-9FJDJW power supply voltage amended from 24-48Vdc to 24-32Vdc
SBIA-98UAW2 releases PRP options
As per SBIA-8YQCWT + SBIA-8ZUAH6 PCBA 2071960A22 replaces ZN0017012
"Stand alone non modulated IRIG-B" (digit 7 = C) removed from offer as per Obsolescence program
GN9025 removed from BOM (no longer used)
HMI assembly amended from GN0178001 to 2072033A01 as per JGAR-8X7AQ8
Vx auxiliary rating amended to 48 - 110 Vdc (from 48-110Vdc (40-100Vac)) per CBUN-8WXJKE
Design suffix C & G options removed from offer as per Obsolescence Program
2071962A01 replaces ZN0019001 and 2071966A01 replaces ZN0031001 as per SBIA-8URHXU
Obsolescence warning added to suffix C & G options
PSUs amended to 2071964xxx as per SBIA-8S6A9S
Tendering sheet added
Obsolescence warning added to "Stand alone non modulated IRIG-B" (digit 7 = C) as per latest obsoletion notice
SW Version 46 released to production, incorporates rebrand and several other enhancements
Update as per latest AG obsoletion notice
Reworked for Schneider Electric requirements
Correction to BOM relating to item AV for suffix "A" variants
References to Alstom and Areva removed. 'Settings files' replaced by 'Customisation'
Lookup correction for Suffix 'G' & UCA2 Protocol
CID ISTE-85VFU7 removed software versions '10' & '16'
PCB descriptions clarified
44' software by CID ISTE-82HLT5
BOM modified in line with PWIG-7ZHCJK making ZN0031001 a model list variable
Redundant Ethernet optons made available, see CIDs ISTE-7YAMBJ & SKEL-7YBM34
'43' Software released; redundant ethernet options added but set as 'not yet available' - see CID ISTE-7RMDSS
Vx rating changed in line with CID BLIN-7P7HJX
"42J" software released by CID ISTE-7LCFEC, also restriction to protocol availability on version '17' software, see
BOM retrospectively amended to include GN0178001AREVA with Suffix G, Russian language options
Explanatory text retrospectively added to '35' software per G Evans
"41J" software released by CID GEVA-7FZEF2, BOM rules corrected for UI & suffix 'G'
BOM rules clarified on Ethernet modules & software licences for Protocols '7' & '8'
Software versions prior to '05' removed from Cortec to maintain concordance with Software History and Compatibility
"40J" software released by CID GEVA-7CEFKM
"36J" software released by CID GEVA-726JEM
Chinese language version was not included in Software Version '35' options
Cortec & Date Drivers retrospectively amended to show revised text for IEC 61850 Comms Protocol (was "IEC
BOMs corrected to add ZB9800801/2 to all variants with digit # 9="6"
All worksheets changed to add High Break and De-Modulated IRIG-B with software "35" effective 01/08/06
Cortec changed to remove Hardware Option "IRIG-B demodulated"
BOM amended. Cortec & Date Drivers text changed for what was just "Chinese HMI"
"35J" Software, IEC61850 and High Break added in line with G Evans' e-mail dated 17/05/06, with a guestimated
DC date of 30/08/06. BOM still requires amendment!!
Correction to Master Text worksheet "In/Vn Rating options"
"34J" Software and Chinese HMI added in line with G Evans' e-mail dated 15/03/06, with a guestimated DC date of
21/03/06. BOM still requires amendment!!
"32J" Software released with DC date of 26/10/05 NB; ethernet options are not available with this issue- CDN
ZN0021*** changed retrospectively to ZN0001*** for 'B' design suffix versions
Hardware options 3 & 4 read "Fibre Optic Converter Only" & "IRIG-B and Fibre Optic Converter"
ZN0028001 was selected for all P142xxxB irrespective of design suffix, ZN0028011 is now set as default for suffix
"J", part 001 for all others
Configurator amended to allow choice of Settings with "G" Hardware & "20" Software.
Configurator amended to allow choice of design suffix and software first to drive the subsequent options
"30J" Software/Hardware released with DC date of 07/01/05
Rules Clarified on jumper links ZB9031759

Livery Option added


Dates amended on Lookup to pick up correct final assembly according to design suffix
"21G" Software/Hardware released as per CDN R3500/193, this is released as One Day Only as "15C" is latest
unless customer specifically requests "21G"

Software "21G" with estimated release date of 07/05/04


Rules modified for Ethernet Licences ZB9800801 & ZB9800802
Software "20G" with "/Russian" language option release date was 16/02/04, now 01/06/04
Software "20G" with "/Russian" language option release date was 19/01/04, now 16/02/04
Software "20G" with "/Russian" language option release date was 01/04/04, now 19/01/04
Design suffix was "C" for all. Now "C" only for "Rear Comms" variants & "B" for the rest
PL2 position added to sub item text on BOM
ZB9800801 & ZB9800802 added to BOM for use when Ethernet is selected
Software issue to "16" for one day to allow for special orders
P142 Cortec created from P14x, now includes UCA2 / Ethernet from 01/03/2003
Rear comms available from 18/11/02
Qty ZB4018110 was 2 less for P14***7******** variants
Incorporate P144
Slot 05 pcb for P142***C******B variants was ZN0017001 in error
Hardware option 4 specified Protocol option 4 in error
Original

BOM

NUMBER

DESCRIPTION

Ref

GN2037001
ZB4018215

BLANKING PLATE.
SELF TAP SCREW SIZE 6x1/4" LG (KAN)

34
61

Qty.
Required

P142911A1M0A08L

Page 9 of 11

255733680.xls.ms_office

1
2
1

12/27/2014

Cortec Landing cell :


Configurator feedback :

P142214A1M0469J
P142911A1M0A08L

13

14

P 1
P 1

4
4

2
2

2
9

1
1

4 A 1 M 0 4 6
1 A 1 M 0 A 0

10

11

12

9
8

0
Cortec digit control 1
Cortec digit control 2
Cortec digit control 3
Cortec digit control 4
Vx Aux Rating
In/Vn Rating
Hardware Options
Product Specific Options
Protocol/Communications Options
Mounting Option
Language
Software
Customisation
Design Suffix

P
1
4
2
1
1
1
1
1
1
1
1
1
1

9
1
1
A
1
M
0
A 0
8

15

20

J
L

double digit in same row

20

5
6
7
8
9
10
11
12
13
14
15
16
17
18
0
0
0
0
0
0
0
0
0
0
0
0

You might also like