Addressing
AddressingCommands
AT
Name and Description
Command
Node
Type1
Parameter Range
Default
DH
Destination Address High.Set/Get the upper 32 bits of the 64-bit destination address.
When combined with DL, it defines the 64-bit destination address for data transmission.
CRE
Special definitions for DH and DL include 0x000000000000FFFF (broadcast) and
0x0000000000000000 (coordinator).
0 - 0xFFFFFFFF
DL
Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address.
When combined with DH, it defines the 64-bit destination address for data
CRE
transmissions. Special definitions for DH and DL include 0x000000000000FFFF
(broadcast) and 0x0000000000000000 (coordinator).
0 - 0xFFFFFFFF
0xFFFF(Coordinator)
0 (Router/End Device)
MY
16-bit Network Address. Read the 16-bit network address of the module. A value of
0xFFFE means the module has not joined a ZigBee network
CRE
0 - 0xFFFE
[read-only]
0xFFFE
MP
16-bit Parent Network Address. Read the 16-bit network address of the module's
parent. A value of 0xFFFE means the module does not have a parent.
0 - 0xFFFE
[read-only]
0xFFFE
NC
Number of Remaining Children. Read the number of end device children that can join
the device. If NC returns 0, then the device cannot allow any more end device children CR
to join.
0 - MAX_CHILDREN
(maximum varies)
read-only
SH
Serial Number High. Read the high 32 bits of the module's unique 64-bit address.
CRE
0 - 0xFFFFFFFF
[read-only]
factory-set
SL
Serial Number Low. Read the low 32 bits of the module's unique 64-bit address.
CRE
0 - 0xFFFFFFFF
[read-only]
factory-set
NI
Node Identifier. Stores a string identifier. The register only accepts printable ASCII
data. In AT Command Mode, a string can not start with a space. A carriage return ends
the command. Command will automatically end when maximum bytes for the string
CRE
have been entered. This string is returned as part of the ND (Node Discover) command.
This identifier is also used with the DN (Destination Node) command. In AT command
mode, an ASCII comma (0x2C) cannot be used in the NI string
20-Byte printable
ASCII string
ASCII space
character (0x20)
SE
Source Endpoint. Set/read the ZigBee application layer source endpoint value. This
value will be used as the source endpoint for all data transmissions. SE is only
supported in AT firmware.The default value 0xE8 (Data endpoint) is the Digi data
endpoint
CRE
0 - 0xFF
0xE8
DE
0 - 0xFF
0xE8
CI
Cluster Identifier. Set/read Zigbee application layer cluster ID value. This value will be
CRE
used as the cluster ID for all data transmissions. CI is only supported in AT
firmware.The default value0x11 (Transparent data cluster ID).
0 - 0xFFFF
0x11
NP
Maximum RF Payload Bytes. This value returns the maximum number of RF payload
bytes that can be sent in a unicast transmission. If APS encryption is used (API transmit
option bit enabled), the maximum payload size is reduced by 9 bytes. If source routing
CRE
is used (AR < 0xFF), the maximum payload size is reduced further.
Note: NP returns a hexadecimal value. (e.g. if NP returns 0x54, this is equivalent to 84
bytes)
0 - 0xFFFF
[read-only]
DD
Device Type Identifier. Stores a device type value. This value can be used to
differentiate different XBee-based devices. Digi reserves the range 0 - 0xFFFFFF.
For example, Digi currently uses the following DD values to identify various ZigBee
products:
0x30001 - ConnectPort X8 Gateway
0x30002 - ConnectPort X4 Gateway
0x30003 - ConnectPort X2 Gateway
0x30005 - RS-232 Adapter
0x30006 - RS-485 Adapter
0x30007 - XBee Sensor Adapter
0x30008 - Wall Router
0x3000A - Digital I/O Adapter
0x3000B - Analog I/O Adapter
0x3000C - XStick
0x3000F - Smart Plug
0x30011 - XBee Large Display
0x30012 - XBee Small Display
0 - 0xFFFFFFFF
0x30000
CRE
Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
2010DigiInternational,Inc.
128
XBee/XBeePROZBRFModules
Networking
NetworkingCommands
AT
Name and Description
Command
Node
Type1
Parameter Range
Default
[read-only]
CH
Operating Channel. Read the channel number used for transmitting and receiving
between RF modules. Uses 802.15.4 channel numbers. A value of 0 means the device CRE
has not joined a PAN and is not operating on any channel.
XBee
0, 0x0B - 0x1A
(Channels 11-26)
XBee-PRO (S2)
0, 0x0B - 0x18
(Channels 11-24)
XBee-PRO (S2B)
0, 0x0B - 0x19
(Channels 11-25)
ID
Extended PAN ID. Set/read the 64-bit extended PAN ID. If set to 0, the coordinator will
select a random extended PAN ID, and the router / end device will join any extended
CRE
PAN ID. Changes to ID should be written to non-volatile memory using the WR
command to preserve the ID setting if a power cycle occurs.
00xFFFFFFFFFFFFFFFF
OP
Operating Extended PAN ID. Read the 64-bit extended PAN ID. The OP value reflects
CRE
the operating extended PAN ID that the module is running on. If ID > 0, OP will equal ID.
0x01 0xFFFFFFFFFFFFFFFF
[read-only]
NH
Maximum Unicast Hops. Set / read the maximum hops limit. This limit sets the
maximum broadcast hops value (BH) and determines the unicast timeout. The timeout
CRE
is computed as (50 * NH) + 100 ms. The default unicast timeout of 1.6 seconds
(NH=0x1E) is enough time for data and the acknowledgment to traverse about 8 hops.
0 - 0xFF
0x1E
BH
Broadcast Hops. Set/Read the maximum number of hops for each broadcast data
transmission. Setting this to 0 will use the maximum number of hops.
0 - 0x1E
OI
Operating 16-bit PAN ID. Read the 16-bit PAN ID. The OI value reflects the actual 16CRE
bit PAN ID the module is running on.
0 - 0xFFFF
[read-only]
NT
Node Discovery Timeout. Set/Read the node discovery timeout. When the network
discovery (ND) command is issued, the NT value is included in the transmission to
provide all remote devices with a response timeout. Remote devices wait a random
time, less than NT, before sending their response.
CRE
0x3C (60d)
CRE
0 - 0x03 [bitfield]
SC
XBee
1 - 0xFFFF [bitfield]
XBee-PRO (S2)
1 - 0x3FFF [bitfield]
(bits 14, 15 not allowed)
XBee-PRO (S2B)
1-0x7FFF
(bit 15 is not allowed)
1FFE
SD
0 - 7 [exponent]
ZS
ZigBee Stack Profile. Set / read the ZigBee stack profile value. This must be set the
same on all devices that should join the same network.
0-2
NO
Network Discovery options. Set/Read the options value for the network discovery
command. The options bitfield value can change the behavior of the ND (network
discovery) command and/or change what optional values are returned in any received
ND responses or API node identification frames. Options include:
0x01 = Append DD value (to ND responses or API node identification frames)
002 = Local device sends ND response frame when ND is issued.
2010DigiInternational,Inc.
CRE
CRE
129
XBee/XBeePROZBRFModules
NetworkingCommands
AT
Name and Description
Command
Node
Type1
Parameter Range
Default
0 - 0xFF
[x 1 sec]
0xFF
(always allows joining)
NJ
Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join.
This value can be changed at run time without requiring a Coordinator or Router to
restart. The time starts once the Coordinator or Router has started. The timer is reset
on power-cycle or when NJ changes.
JV
NW
0 - 0x64FF
[x 1 minute]
(up to over 17 days)
0 (disabled)
JN
Join Notification. Set / read the join notification setting. If enabled, the module will
transmit a broadcast node identification packet on power up and when joining. This
action blinks the Associate LED rapidly on all devices that receive the transmission, and RE
sends an API frame out the UART of API devices. This feature should be disabled for
large networks to prevent excessive broadcasts.
0-1
AR
0 - 0xFF
0xFF
2010DigiInternational,Inc.
CR
0 - Channel verification
disabled
1 - Channel verification
enabled
130
XBee/XBeePROZBRFModules
Security
SecurityCommands
AT
Name and Description
Command
Node
Parameter Range
Type1
EE
CRE
EO
Encryption Options. Configure options for encryption. Unused option bits should be set
to 0. Options include:
CRE
0x01 - Send the security key unsecured over-the-air during joins
0x02 - Use trust center (coordinator only
0 - 0xFF
NK
Network Encryption Key. Set the 128-bit AES network encryption key. This command
is write-only; NK cannot be read. If set to 0 (default), the module will select a random
network key.
128-bit value
KY
Link Key. Set the 128-bit AES link key. This command is write only; KY cannot be read.
Setting KY to 0 will cause the coordinator to transmit the network key in the clear to
CRE
joining devices, and will cause joining devices to acquire the network key in the clear
when joining.
128-bit value
0 - Encryption disabled
1 - Encryption enabled
Default
0
RF Interfacing
RFInterfacingCommands
AT
Name and Description
Command
Node
Parameter Range
Type1
Default
XBee
(boost mode disabled)
0 = -8 dBm
1 = -4 dBm
2 = -2 dBm
3 = 0 dBm
4 = +2 dBm
XBee-PRO (S2)
4 = 17 dBm
XBee-PRO (S2)
(International Variant)
4 = 10dBm
PL
Power Level. Select/Read the power level at which the RF module transmits conducted
power. For XBee-PRO (S2B) Power Level 4 is calibrated and the other power levels are CRE
approximate.
PM
Power Mode. Set/read the power mode of the device. Enabling boost mode will improve
the receive sensitivity by 1dB and increase the transmit power by 2dB
CRE
Note: Enabling boost mode on the XBee-PRO (S2) will not affect the output power. Boost
mode imposes a slight increase in current draw. See section 1.2 for details.
0-1,
0= -Boost mode disabled,
1= Boost mode enabled. 1
DB
Received Signal Strength. This command reports the received signal strength of the
last received RF data packet. The DB command only indicates the signal strength of the
last hop. It does not provide an accurate quality measurement for a multihop link. DB can
be set to 0 to clear it. The DB command value is measured in -dBm. For example if DB CRE
returns 0x50, then the RSSI of the last packet received was
-80dBm. As of 2x6x firmware, the DB command value is also updated when an APS
acknowledgment is received.
0 - 0xFF
Observed range for
XBee-PRO:
0x1A - 0x58
For XBee:
0x 1A - 0x5C
PP
Peak Power. Read the dBm output when maximum power is selected (PL4).
0x0-0x12
CRE
XBee-PRO (S2B)
(Boost mode enabled)
4 = 18dBM
3 = 16dBm
2 = 14dBm
1 = 12dBm
0 = 10dBm
XBee-PRO (S2B)
(International Variant)
(Boost mode enabled)
4 = 10dBm
3 = 8dBm
2 = 6dBm
1 = 4dBm
0 = 2dBm
[read only]
1.Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
2010DigiInternational,Inc.
131
XBee/XBeePROZBRFModules
Serial Interfacing (I/O)
SerialInterfacingCommands
AT
Name and Description
Command
AP
AO
API Options. Configure options for API. Current options select the type of receive API
frame to send out the Uart for received RF data packets.
Node
Parameter Range
Type1
Default
CRE
1 - 2
1 = API-enabled
2 = API-enabled
1
(w/escaped control
characters)
CRE
BD
Interface Data Rate. Set/Read the serial interface data rate for communication between
the module serial port and host.
CRE
Any value above 0x07 will be interpreted as an actual baud rate. When a value above
0x07 is sent, the closest interface data rate represented by the number is stored in the
BD register.
0-7
(standard baud rates)
0 = 1200 bps
1 = 2400
2 = 4800
3 = 9600
3
4 = 19200
5 = 38400
6 = 57600
7 = 115200
0x80 - 0xE1000
(non-standard rates up to
921kbps)
NB
CRE
0 = No parity
1 = Even parity
2 = Odd parity
3 = Mark parity
SB
Stop Bits. Set/read the number of stop bits for the UART. (Two stop bits are not
supported if mark parity is enabled.)
CRE
0 = 1 stop bit
1 = 2 stop bits
RO
0 - 0xFF
[x character times]
DIO7 Configuration. Select/Read options for the DIO7 line of the RF module.
CRE
0 = Disabled
1 = CTS Flow Control
3 = Digital input
4 = Digital output, low
5 = Digital output, high
6 = RS-485 transmit
enable (low enable)
7 = RS-485 transmit
enable (high enable)
CRE
0 = Disabled
1 = RTS flow control
3 = Digital input
4 = Digital output, low
5 = Digital output, high
D7
D6
DIO6 Configuration. Configure options for the DIO6 line of the RF module.
1.Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
2010DigiInternational,Inc.
132
XBee/XBeePROZBRFModules
I/O Commands
I/OCommands
AT
Name and Description
Command
Node
Parameter Range
Type1
Default
IR
IO Sample Rate. Set/Read the IO sample rate to enable periodic sampling. For periodic
sampling to be enabled, IR must be set to a non-zero value, and at least one module pin
CRE
must have analog or digital IO functionality enabled (see D0-D8, P0-P2 commands). The
sample rate is measured in milliseconds.
0, 0x32:0xFFFF (ms)
IC
IO Digital Change Detection. Set/Read the digital IO pins to monitor for changes in the
IO state. IC works with the individual pin configuration commands (D0-D8, P0-P2). If a
pin is enabled as a digital input/output, the IC command can be used to force an
immediate IO sample transmission when the DIO state changes. IC is a bitmask that can
be used to enable or disable edge detection on individual channels. Unused bits should
CRE
be set to 0.
Bit (IO pin): 0 (DIO0)4 (DIO4)8 (DIO8)
1 (DIO1) 5 (DIO5) 9 (DIO9)
2 (DIO2) 6 (DIO6) 10 (DIO10)
3 (DIO3) 7 (DIO7) 11 (DIO11)
: 0 - 0xFFFF
CRE
0 = Disabled
1 = RSSI PWM
3 - Digital input,
monitored
4 - Digital output, default
low
5 - Digital output, default
high
CRE
0 - Unmonitored digital
input
3- Digital input,
monitored
4- Digital output, default
low
5- Digital output, default
high
P0
P1
P2
P3
D0
D1
D2
DIO11 Configuration. Configure options for the DIO11 line of the RF module.
DIO12 Configuration. Configure options for the DIO12 line of the RF module.
DIO13 Configuration. Set/Read function for DIO13. This command is not yet
supported.
2010DigiInternational,Inc.
CRE
0 - Unmonitored digital
input
3- Digital input,
monitored
4- Digital output, default
low
5- Digital output, default
high
CRE
0, 3-5
0 Disabled
3 Digital input
4 Digital output, low
5 Digital output, high
CRE
1 - Commissioning button
enabled
2 - Analog input, single
ended
1
3 - Digital input
4 - Digital output, low
5 - Digital output, high
CRE
0, 2-5
0 Disabled
2 - Analog input, single
ended
3 Digital input
4 Digital output, low
5 Digital output, high
CRE
0, 2-5
0 Disabled
2 - Analog input, single
ended
3 Digital input
4 Digital output, low
5 Digital output, high
133
XBee/XBeePROZBRFModules
I/OCommands
AT
Name and Description
Command
D3
D4
Node
Parameter Range
Type1
Default
CRE
0, 2-5
0 Disabled
2 - Analog input, single
ended
3 Digital input
4 Digital output, low
5 Digital output, high
CRE
0, 3-5
0 Disabled
3 Digital input
4 Digital output, low
5 Digital output, high
D5
DIO5 Configuration. Configure options for the DIO5 line of the RF module.
CRE
0 = Disabled
1 = Associated
indication LED
3 = Digital input
1
4 = Digital output, default
low
5 = Digital output, default
high
D8
DIO8 Configuration. Set/Read function for DIO8. This command is not yet supported. CRE
0, 3-5
0 Disabled
3 Digital input
4 Digital output, low
5 Digital output, high
LT
Assoc LED Blink Time. Set/Read the Associate LED blink time. If the Associate LED
functionality is enabled (D5 command), this value determines the on and off blink times
for the LED when the module has joined a network. If LT=0, the default blink rate will be CRE
used (500ms coordinator, 250ms router/end device). For all other LT values, LT is
measured in 10ms.
PR
Pull-up Resistor. Set/read the bit field that configures the internal pull-up resistor status
for the I/O lines. "1" specifies the pull-up resistor is enabled. "0" specifies no pullup.(30k
pull-up resistors)
Bits:"
0 - DIO4 (Pin 11)
1 - AD3 / DIO3 (Pin 17)
2 - AD2 / DIO2 (Pin 18)
3 - AD1 / DIO1 (Pin 19)
4 - AD0 / DIO0 (Pin 20)
CRE
5 - RTS / DIO6 (Pin 16)
6 - DTR / Sleep Request / DIO8 (Pin 9)
7 - DIN / Config (Pin 3)
8 - Associate / DIO5 (Pin 15)
9 - On/Sleep / DIO9 (Pin 13)
10 - DIO12 (Pin 4)
11 - PWM0 / RSSI / DIO10 (Pin 6)
12 - PWM1 / DIO11 (Pin 7)
13 - CTS / DIO7 (Pin 12)
0 - 0x3FFF
0 - 0x1FFF
RP
RSSI PWM Timer. Time the RSSI signal will be output on the PWM after the last RF data
CRE
reception or APS acknowledgment.. When RP = 0xFF, output will always be on.
0x28 (40d)
%V
Supply Voltage. Reads the voltage on the Vcc pin. Scale by 1200/1024 to convert to
mV units. For examplee, a %V reading of 0x900 (2304 decimal) represents 2700mV or
2.7OV.
V+
Voltage Supply Monitoring. The voltage supply threshold is set with the V+ command.
If the measured supply voltage falls below or equal to this threshold, the supply voltage
will be included in the IO sample set. V+ is set to 0 by default (do not include the supply
voltage). Scale mV units by 1024/1200 to convert to internal units. For example, for a
2700mV threshold enter 0x900.
CRE
Given the operating Vcc ranges for different platforms, and scaling by 1024/1200, the
useful parameter ranges are:
XBee 2100-3600 mV 0,0x0700-0x0c00
PRO 3000-3400 mV, 0,0x0a00-0x0b55
S2B 2700-3600 mV, 0,0x0900-0x0c00
0-0xFFFF
TP
0x0-0xFFFF
2010DigiInternational,Inc.
CRE
CRE
134
XBee/XBeePROZBRFModules
Diagnostics
DiagnosticsCommands
AT
Name and Description
Command
Node
Parameter Range
Type1
Default
CRE
0 - 0xFFFF [read-only]
Factory-set
CRE
0 - 0xFFFF [read-only]
Factory-set
0 - 0xFF
[read-only]
--
HV
Hardware Version. Read the hardware version of the module.version of the module.
This command can be used to distinguish among different hardware platforms. The
upper byte returns a value that is unique to each module type. The lower byte indicates
the hardware revision.
XBee ZB and XBee ZNet modules return the following (hexadecimal) values:
0x19xx - XBee module
0x1Axx - XBee-PRO module
AI
1.Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
AT Command Options
ATCommandOptionsCommands
AT
Name and Description
Command
Node
Parameter Range
Type1
Default
CT
Command Mode Timeout. Set/Read the period of inactivity (no valid commands
received) after which the RF module automatically exits AT Command Mode and returns CRE
to Idle Mode.
0x64 (100d)
CN
Exit Command Mode. Explicitly exit the module from AT Command Mode.
--
--
GT
Guard Times. Set required period of silence before and after the Command Sequence
Characters of the AT Command Mode Sequence (GT + CC + GT). The period of silence CRE
is used to prevent inadvertent entrance into AT Command Mode.
1 - 0x0CE4 [x 1 ms]
0x3E8
(max of 3.3 decimal sec) (1000d)
CC
0 - 0xFF
CRE
CRE
0x2B
(+ ASCII)
1.Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
2010DigiInternational,Inc.
135
XBee/XBeePROZBRFModules
Sleep Commands
SleepCommands
Node
Parameter Range
Type1
AT
Name and Description
Command
Default
SM
Sleep Mode Sets the sleep mode on the RF module. An XBee loaded with router
firmware can be configured as either a router (SM set to 0) or an end device (SM > 0).
RE
Changing a device from a router to an end device (or vice versa) forces the device to
leave the network and attempt to join as the new device type when changes are applied.
SN
Number of Sleep Periods. Sets the number of sleep periods to not assert the On/Sleep
pin on wakeup if no RF data is waiting for the end device. This command allows a host CRE
application to sleep for an extended time if no RF data is present
1 - 0xFFFF
SP
Sleep Period. This value determines how long the end device will sleep at a time, up to
28 seconds. (The sleep time can effectively be extended past 28 seconds using the SN
command.) On the parent, this value determines how long the parent will buffer a
CRE
message for the sleeping end device. It should be set at least equal to the longest SP
time of any child end device.
0x20
ST
Time Before Sleep Sets the time before sleep timer on an end device.The timer is reset
each time serial or RF data is received. Once the timer expires, an end device may enter E
low power operation. Applicable for cyclic sleep end devices only.
1 - 0xFFFE (x 1ms)
0x1388 (5
seconds)
SO
Command
Sleep Options. Configure options for sleep. Unused option bits should be set to 0.
Sleep options include:
0x02 - Always wake for ST time
0x04 - Sleep entire SN * SP time
Sleep options should not be used for most applications. See chapter 6 for more
information.
0 - 0xFF
WH
Wake Host. Set/Read the wake host timer value. If the wake host timer is set to a nonzero value, this timer specifies a time (in millisecond units) that the device should allow
E
after waking from sleep before sending data out the UART or transmitting an IO sample.
If serial characters are received, the WH timer is stopped immediately.
SI
PO
Polling Rate. Sets the polling rate for the end device.
0 - 0xFFFF (x 1ms)
0 - 0x1770 (10msec)
0x00 (100
msec)
Execution Commands
Where most AT commands set or query register values, execution commands cause an action to
be executed on the module. Execution commands are executed immediately and do not require
changes to be applied.
ExecutionCommands
AT
Name and Description
Command
Node Type1
AC
Apply Changes. Applies changes to all command registers causing queued command
register values to be applied. For example, changing the serial interface rate with the BD
CRE
command will not change the UART interface rate until changes are applied with the AC
command. The CN command and 0x08 API command frame also apply changes.
WR
--
--
RE
CRE
--
--
FR
Software Reset. Reset module. Responds immediately with an OK status, and then
performs a software reset about 2 seconds later.
CRE
--
--
NR
Network Reset. Reset network layer parameters on one or more modules within a PAN.
Responds immediately with an OK then causes a network restart. All network
configuration and routing information is consequently lost.
If NR = 0: Resets network layer parameters on the node issuing the command.
If NR = 1: Sends broadcast transmission to reset network layer parameters on all nodes
in the PAN.
CRE
0-1
--
SI
Sleep Immediately. Cause a cyclic sleep module to sleep immediately rather than wait
for the ST timer to expire.
CB
2010DigiInternational,Inc.
136
XBee/XBeePROZBRFModules
ExecutionCommands
AT
Name and Description
Command
Node Type1
ND
Node Discover. Discovers and reports all RF modules found. The following information
is reported for each module discovered.
MY<CR>
SH<CR>
SL<CR>
NI<CR> (Variable length)
PARENT_NETWORK ADDRESS (2 Bytes)<CR>
DEVICE_TYPE<CR> (1 Byte: 0=Coord, 1=Router, 2=End Device)
STATUS<CR> (1 Byte: Reserved)
PROFILE_ID<CR> (2 Bytes)
CRE
MANUFACTURER_ID<CR> (2 Bytes)
<CR>
After (NT * 100) milliseconds, the command ends by returning a <CR>. ND also accepts
a Node Identifier (NI) as a parameter (optional). In this case, only a module that matches
the supplied identifier will respond.
If ND is sent through the API, each response is returned as a separate
AT_CMD_Response packet. The data consists of the above listed bytes without the
carriage return delimiters. The NI string will end in a "0x00" null character. The radius of
the ND command is set by the BH command.
optional 20-Byte
NI or MY value
DN
Destination Node. Resolves an NI (Node Identifier) string to a physical address (casesensitive). The following events occur after the destination node is discovered:
<AT Firmware>
1. DL & DH are set to the extended (64-bit) address of the module with the matching
NI (Node Identifier) string.
2. OK (or ERROR)\r is returned.
3. Command Mode is exited to allow immediate communication
CRE
<API Firmware>
1. The 16-bit network and 64-bit extended addresses are returned in an API
Command Response frame.
If there is no response from a module within (NT * 100) milliseconds or a parameter is
not specified (left blank), the command is terminated and an ERROR message is
returned. In the case of an ERROR, Command Mode is not exited. The radius of the DN
command is set by the BH command.
up to 20-Byte printable
-ASCII string
IS
Force Sample Forces a read of all enabled digital and analog input lines.
--
--
1S
XBee Sensor Sample. Forces a sample to be taken on an XBee Sensor device. This
RE
command can only be issued to an XBee sensor device using an API remote command.
CRE
--
Nodetypesthatsupportthecommand:C=Coordinator,R=Router,E=EndDevice
2010DigiInternational,Inc.
137