E-2
API STANDARD 650
Dynamic analysis methods incorporating fluid-structure and soil-structure interaction are permitted to be used in lieu
of the procedures contained in this Annex with Purchaser approval and provided the design and construction details
are as safe as otherwise provided in this Annex.
E.2 Definitions and Notations
E.2.1 Definitions
--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---
E.2.1.1
active fault
A fault for which there is an average historic slip rate of 1 mm (0.4 in.) per year or more and geologic evidence of
seismic activity within Holocene times (past 11,000 years).
E.2.1.2
characteristic earthquake
An earthquake assessed for an active fault having a magnitude equal to the best-estimate of the maximum
magnitude capable of occurring on the fault, but not less than the largest magnitude that has occurred historically on
the fault.
E.2.1.3
maximum considered earthquake
MCE
The most severe earthquake ground motion considered in this Annex.
E.2.1.4
mechanically-anchored tank
Tanks that have anchor bolts, straps or other mechanical devices to anchor the tank to the foundation.
E.2.1.5
self-anchored tank
Tanks that use the inherent stability of the self-weight of the tank and the stored product to resist overturning forces.
E.2.1.6
site class
A classification assigned to a site based on the types of soils present and their engineering properties as defined in
this Annex.
E.2.2 Notations
A
Lateral acceleration coefficient, %g
Ac
Convective design response spectrum acceleration parameter, = (2/3) x 0.7 x SDS = 0.47 SDS, %g
Af
Acceleration coefficient for sloshing wave height calculation, %g
Ai
Impulsive design response spectrum acceleration coefficient, %g
Av
Vertical earthquake acceleration parameter = (2/3) x 0.7 x SDS = 0.47 SDS, %g
Cd
Deflection amplification factor, Cd = 2
Ci
Coefficient for determining impulsive period of tank system
WELDED TANKS FOR OIL STORAGE
E-3
Nominal tank diameter, m (ft)
dc
Total thickness (100 ds) of cohesive soil layers in the top 30 m (100 ft)
di
Thickness of any soil layer i (between 0 and 30 m [100 ft])
ds
Total thickness of cohesionless soil layers in the top 30 m (100 ft)
Elastic Modulus of tank material, MPa (lbf/in.2)
Fa
Acceleration-based site coefficient (at 0.2 sec period)
Fc
Allowable longitudinal shell-membrane compression stress, MPa (lbf/in.2)
Fty
Minimum specified yield strength of shell course, MPa (lbf/in.2)
Fv
Velocity-based site coefficient (at 1.0 sec period)
Fy
Minimum specified yield strength of bottom annulus, MPa (lbf/in.2)
Specific gravity
Acceleration due to gravity in consistent units, m/sec2 (ft/sec2)
Ge
Effective specific gravity including vertical seismic effects = G (1 0.4Av)
Maximum design product level, m (ft)
HS
Thickness of soil, m (ft)
Importance factor coefficient set by seismic use group
Anchorage ratio
Coefficient to adjust the spectral acceleration from 5 % to 0.5 % damping = 1.5 unless otherwise specified
Required minimum width of thickened bottom annular ring measured from the inside of the shell m (ft)
Ls
Selected width of annulus (bottom or thickened annular ring) to provide the resisting force for self
anchorage, measured from the inside of the shell m (ft)
ta
Thickness, excluding corrosion allowance, mm (in.) of the bottom annulus under the shell required to
provide the resisting force for self anchorage. The bottom plate for this thickness shall extend radially at
least the distance, L, from the inside of the shell. This term applies for self-anchored tanks only.
Mrw
Ringwall momentPortion of the total overturning moment that acts at the base of the tank shell
perimeter, Nm (ft-lb)
Ms
Slab moment (used for slab and pile cap design), Nm (ft-lb)
Standard penetration resistance, ASTM D1586
Average field standard penetration test for the top 30 m (100 ft)
--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---
E-4
API STANDARD 650
nA
Number of equally-spaced anchors around the tank circumference
Nc
Convective hoop membrane force in tank shell, N/mm (lbf/in.)
Nch
Average standard penetration of cohesionless soil layers for the top 30 m (100 ft)
Nh
Product hydrostatic membrane force, N/mm (lbf/in.)
Ni
Impulsive hoop membrane force in tank shell, N/mm (lbf/in.)
PA
Anchorage attachment design load, N (lbf)
PAB
Anchor design load, N (lbf)
Pf
Overturning bearing force based on the maximum longitudinal shell compression at the base of shell, N/m
(lbf/ft)
PI
Plasticity index, ASTM D4318
Scaling factor from the MCE to the design level spectral accelerations; equals 2/3 for ASCE 7
Force reduction coefficient for strength level design methods
Rwc
Force reduction coefficient for the convective mode using allowable stress design methods
Rwi
Force reduction factor for the impulsive mode using allowable stress design methods
S0
Mapped, maximum considered earthquake, 5 % damped, spectral response acceleration parameter at a
period of zero seconds (peak ground acceleration for a rigid structure), %g
S1
Mapped, maximum considered earthquake, 5 % damped, spectral response acceleration parameter at a
period of one second, %g
Sa
The 5 % damped, design spectral response acceleration parameter at any period based on mapped,
probabilistic procedures, %g
Sa*
The 5 % damped, design spectral response acceleration parameter at any period based on site-specific
procedures, %g
Sa0*
The 5 % damped, design spectral response acceleration parameter at zero period based on site-specific
procedures, %g
SD1
The design, 5 % damped, spectral response acceleration parameter at one second based on the ASCE 7
methods, equals Q Fv S1, %g
SDS
The design, 5% damped, spectral response acceleration parameter at short periods (T = 0.2 seconds)
based on ASCE 7 methods, equals Q Fa Ss, %g
SP
Design level peak ground acceleration parameter for sites not addressed by ASCE methods. [See EC
Example Problem 2 when using Z factor from earlier editions of API 650 and UBC. Since 475 year
recurrence interval is basis of this peak ground acceleration, Q = 1.0 (no scaling).]
SS
Mapped, maximum considered earthquake, 5% damped, spectral response acceleration parameter at
short periods (0.2 sec), %g
su
Undrained shear strength, ASTM D2166 or ASTM D2850
WELDED TANKS FOR OIL STORAGE
E-5
su
Average undrained shear strength in top 30 m (100 ft)
Thickness of the shell ring under consideration, mm (in.)
ta
Thickness, excluding corrosion allowance, mm (in.) of the bottom annulus under the shell required to
provide the resisting force for self anchorage. The bottom plate for this thickness shall extend radially at
least the distance, L, from the inside of the shell. this term applies for self-anchored tanks only.
tb
Thickness of tank bottom less corrosion allowance, mm (in.)
ts
Thickness of bottom shell course less corrosion allowance, mm (in.)
tu
Equivalent uniform thickness of tank shell, mm (in.)
Natural period of vibration of the tank and contents, seconds
TC
Natural period of the convective (sloshing) mode of behavior of the liquid, seconds
Ti
Natural period of vibration for impulsive mode of behavior, seconds
TL
Regional-dependent transition period for longer period ground motion, seconds
T0
0.2 FvS1 / FaSS
TS
FvS1 / FaSS
Total design base shear, N (lbf)
Vc
Design base shear due to the convective component of the effective sloshing weight, N (lbf)
vs
Average shear wave velocity at large strain levels for the soils beneath the foundation, m/s (ft/s)
vs
Average shear wave velocity in top one 30 m (100 ft), m/s (ft/s)
Vi
Design base shear due to impulsive component from effective weight of tank and contents, N (lbf)
Moisture content (in %), ASTM D2216
wa
Force resisting uplift in annular region, N/m (lbf/ft)
wAB
Calculated design uplift load on anchors per unit circumferential length, N/m (lbf/ft)
Wc
Effective convective (sloshing) portion of the liquid weight, N (lbf)
Weff
Effective weight contributing to seismic response
Wf
Weight of the tank bottom, N (lbf)
Wfd
Total weight of tank foundation, N (lbf)
Wg
Weight of soil directly over tank foundation footing, N (lbf)
Wi
Effective impulsive portion of the liquid weight, N (lbf)
wint
Calculated design uplift load due to product pressure per unit circumferential length, N/m (lbf/ft)
--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---
E-6
API STANDARD 650
Wp
Total weight of the tank contents based on the design specific gravity of the product, N (lbf)
Wr
Total weight of fixed tank roof including framing, knuckles, any permanent attachments and 10 % of the
roof design snow load, N (lbf)
Wrs
Roof load acting on the tank shell including 10 % of the roof design snow load, N (lbf)
wrs
Roof load acting on the shell, including 10 % of the specified snow load N/m (lbf/ft)
Ws
Total weight of tank shell and appurtenances, N (lbf)
WT
Total weight of tank shell, roof, framing, knuckles, product, bottom, attachments, appurtenances,
participating snow load, if specified, and appurtenances, N (lbf)
wt
Tank and roof weight acting at base of shell, N/m (lbf/ft)
Xc
Height from the bottom of the tank shell to the center of action of lateral seismic force related to the
convective liquid force for ringwall moment, m (ft)
Xcs
Height from the bottom of the tank shell to the center of action of lateral seismic force related to the
convective liquid force for the slab moment, m (ft)
Xi
Height from the bottom of the tank shell to the center of action of the lateral seismic force related to the
impulsive liquid force for ringwall moment, m (ft)
Xis
Height from the bottom of the tank shell to the center of action of the lateral seismic force related to the
impulsive liquid force for the slab moment, m (ft)
Xr
Height from the bottom of the tank shell to the roof and roof appurtenances center of gravity, m (ft)
Xs
Height from the bottom of the tank shell to the shells center of gravity, m (ft)
Distance from liquid surface to analysis point, (positive down), m (ft)
yu
Estimated uplift displacement for self-anchored tank, mm (in.)
Maximum longitudinal shell compression stress, MPa (lbf/in.2)
Product hydrostatic hoop stress in the shell, MPa (lbf/in.2)
Hoop stress in the shell due to impulsive and convective forces of the stored liquid, MPa (lbf/in.2)
Total combined hoop stress in the shell, MPa (lbf/in.2)
--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---
Friction coefficient for tank sliding
Density of fluid, kg/m3 (lb/ft3)
E.3 Performance Basis
E.3.1 Seismic Use Group
The Seismic Use Group (SUG) for the tank shall be specified by the Purchaser. If it is not specified, the SUG shall be
assigned to be SUG I.