Metal Clad TX GSM Dialler Instructions
Metal Clad TX GSM Dialler Instructions
Metal Clad TX GSM Dialler Instructions
Installation Guide
1. Insert a SIM card to the alarm unit.
Press the yellow button next to the card slot gently with a small screwdriver. The SIM card tray will
come out. Put the SIM card in correct direction (metal contacts face down) and insert into the
system carefully.
Attention! Metal contacts of the SIM card must face down. Make sure it is inserted correctly into the
unit.
**Before inserting SIM card into the alarm unit, use a regular mobile phone to do the following
steps:
- Set the SIM card PIN code (Password) request to off.
- Delete all stored numbers or any message histories
2. Connect the antennas.
Attention! Be careful, do not over-tighten the antennas! Connect the antennas before power up the
system.
3. Connect the (optional) siren to alarm system.
Connect solid black wire to GND port and red (or black-white) wire to SIREN port. If the siren has two
white wires instead, connect smooth surface wire to GND and patterned wire to SIREN port.
4. Connecting wired sensors.
Three inputs are available to connect wired sensors. Inputs are independent, but they share the
same SMS alert message (with zone number indicating which wired zone is triggered at the end of
the message). When the alarm is set off via the wired sensors and send out a SMS, it will show Wired
Activated (J), (J = 1-3).
Sensors can be NO (normally open) or NC (normally close) type.
You can connect more than one sensor at one input by connecting the sensors in parallel for NO or
in series for NC (< 200Ohms).
5. Connecting switched output devices (Home-appliance Control)
The system has two open collector outputs (OUT1 and OUT2), one speaker output (KTLK), and one
internal relay (RELAY) controlled by telephone or SMS text commands.
Internal onboard relay is activated for two minutes when an alarm occurs and it can be controlled
through telephone or SMS text commands.
It can be used for example, to turn on a lamp to scare away the thief.
The open collector outputs can be used directly, if your equipment allows this, it can operate a relay.
1#0# (Disarm)
3#0# (Off)
4#0# (Off)
11#0# (Off)
12#0# (Off)
15#0# (Off)
(15) Edit the fourth group phone number: 54# Phone number (0~15bit)#
(16) Edit the fifth group phone number: 55# Phone number (0~15bit)#
(17) Require the content of the SMS: 80##
(18) Edit the first zone alarm SMS: 81#the content of SMS (0~24 letters)#
(19) Edit the second zone alarm SMS: 82#the content of SMS (0~24 letters)#
(20) Edit the third zone alarm SMS: 83#the content of SMS (0~24 letters)#
(21) Edit the I alarm SMS: 84#the content of SMS (0~24 letters)#, (I = Zone 4~16)
(22) Edit the wired zone alarm SMS: 85#the content of SMS (0~24 letters)#, (Wired Zone 1~3)
(23) Require the status of outlet: 90##
(24) Set the OUT1: 91#1# (Outlet 1 high)
3. How to setup the alarm phone numbers (5 groups) and the content of SMS alerts (5 groups)?
1. User can send a SMS to set the alarm phone number, and the SMS command should be sent as
follow:
password#operating code 51-55#phone number#
Send SMS: 123456#51#1st phone number#, means storing 1st phone number.
Send SMS: 123456#52#2nd phone number#, means storing 2nd phone number.
Send SMS: 123456#53#3rd phone number#, means storing 3rd phone number.
Send SMS: 123456#54#4th phone number#, means storing 4th phone number.
Send SMS: 123456#55#5th phone number#, means storing 5th phone number.
Send SMS to delete a stored phone number: 123456#51##, means deleting the 1st phone number.
Other phone numbers can be deleted using similar method but changing to 52##, 53##, 54##, and
55##.
2. How to add new sensors to the alarm system (Registering wireless sensors with control unit)
Sensors and remote controls delivered in kit are already added (registered) to the system. Plug in DC
12V power supply to the alarm system.
If the alarm system needs to add new sensors, such as PIR motion sensors, remote controls, and so
on, you can do so within the 20 seconds after the power is on. After applying 12Vdc to the system,
when signal LED light is in red colour, trigger the sensor you want to match to the system to emit a
signal. If the main unit picks up this signal, the wired siren will give short rings and signal LED will
flash in red. If no sensor is triggered within 20 seconds, the system starts to search for GSM network
and signal LED flashes in orange.
Test all sensors after adding to the system and repeat above procedures if more sensors need to be
added.
Maximum number of wireless zones that can be coded by the system is 16. But you can register
countless wireless sensors by grouping sensors to the same zone (same address code, 8-digit jumper
setting in sensors).
3. How to cancel the lost remote controllers in the alarm system
If a remote sensor is lost, the user needs to clear this remote controller. Press the RESET key on the
back of the alarm system and then plug in power. The status / signal light flashes once meaning the
alarm system reset successfully. After resetting the alarm system, all setup come back to the time
when it came from the factory. The origin password is 123456. Repeat the add sensor instructions
above to match back other sensors and remotes.
4. How to test the alarm system function
When the power is on and turns into the disarm status, users can arm it through remote controller
(arm key) or by sending a SMS (Password#1#1#)
When the alarm system is in arm status, the red light flashes slowly if the wired inputs trigger the
alarm or wireless sensors trigger the alarm.
1. If the SMS alarming function is enabled, the system will send the corresponding SMS based on the
trigger port (wired IN1, wired IN2, wired IN3, wireless sensors). It will then call the stored numbers.
If the SMS alarming function is disabled, it will just call the stored number directly.
2. After the alarm is set off and the system calls you, you do not need to input the password again to
control the system.
Standard components and optional available components
Troubleshooting Section
GSM Problem - The light keeps flashing orange meaning the GSM network has not been established.
1. The SIM card circuit side should face downwards, slide the sim card holder into the slot of the
main unit carefully to make sure the card has the contact with the main unit circuit board.
2. The SIM card should use 900/1800/1900 MHz GSM Band. Only use GSM SIM card, not CDMA or
3G.
3. Make sure the SIM card has NO password, NO phone number, or any message history in it.
4. Apply the power with the 12V 2A power adapter we supplied and connect it to the main supply.
5. Use the antenna; this is for the GSM reception.
6. If possible try with another unlocked SIM card (different company), or try the alarm at another
location to check GSM reception.
If the alarm has established a GSM network, then the signal LED should change to green colour.
Sensors / Remotes - The sensor does not trigger the alarm system
1. Check the sensor battery.
2. Re-match the sensor to the system according to adding a new sensor section.