Electricity Meters IEC/MID

Industrial and Commercial

ZMG310AR/CR

E550 Series 2
Technical Data

Building on its tradition of industrial meters, Landis+Gyr is now


bringing out the E550 Series 2, the latest generation of ZMG300 meters.
The E550 Series 2 offers two electrical interfaces, advanced modem solution,
event logging and anti-tampering functions.

Date: 20.01.2012
File name: D000029744 E550 ZMG310xR Series 2 Technical Data en.docx
Landis+Gyr

D000029744 en h

2/10

Revision history
Version

Date

Comments

17.02.2010

First edition

be

23.07.2010

Continuous improvement

01.12.2011

Corrected error in solid state output (DC deleted)

02.12.2011

Corrected error in electromechanical output (DC deleted)

20.01.2012

New extension boards 060 with 6 output contacts and 240 with 2 control inputs and
4 output contacts.

Nothing in this document shall be construed as a representation or guarantee in respect of the performance, quality or durability of the
specified product. Landis+Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document.
Subject to change without notice.

Landis+Gyr

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

3/10
The E550 direct connected I&C meters record
active and reactive energy consumption in 1-phase
2-wire, 2-phase 3-wire, 3-phase 4-wire and 3-phase
3-wire (no neutral) networks.
Basic Version
The basic version provides energy registers for
tariffication, red test diodes for active and reactive
energy, an optical interface for meter reading and
an electrical interface.

Interfaces
The Series 2 now supports two independent electrical interfaces.
The meter supports RS232, RS485, RS422, CS
and a specially powered RS232 to supply external
modems.
Installation support
The monitoring of voltage, current, demand and
power factor supports the installation.

E550 Series 2 ZMG310AR/CR Technical specifications


General

Measurement Behaviour

Voltage
Nominal voltage Un ZMG310xR
3 x 220/380 V to 240/415 V
3 x 110/190 V to 133/230 V
3 x 110/190 V to 277/480 V
Voltage range

80% to 115% Un

Frequency

Starting current
According to IEC
0.4% Ib
Typical
0.3% Ib
The startup of the meter is controlled by the starting
power and not by the starting current.
Starting power in M-circuit
Nominal voltage x starting current
MID-specific Data

Nominal frequency fn
Tolerance

50 or 60 Hz
2%

Current (for class B)


Reference current Iref selectable: 5, 10, 15 or 20 A

Application
1 phase 2 wire; 2 phase 3 wire; 3 phase 4 wire, 3phase 3-wire (without neutral)

IEC-specific Data

Minimum current Imin

selectable: 5, 10, 20 or 40 A

0.1 x Iref

Maximum current Imax


With aluminium wires

125 A
80 A

Short circuit 10 ms

10,000 A

to EN 50470-3
class B

Measurement Behaviour
Starting current Ist

0.004 x Iref

General

Operating Behaviour

Measurement Accuracy
ZMG310xR
Active energy, to IEC 62053-21
Reactive energy, to IEC 62053-23

Measurement Accuracy
ZMG310xR

Maximum current Imax


Metrological selectable: 40, 60, 80, 100 or 125 A
Thermal
125 A
With aluminium wires
80 A

0.05 x Iref

Transitional current Itr

Current
Base current Ib

single phase

class 1
class 2

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

Voltage failure (Power Down)


Bridging time
Data storage
Switch off (at rated voltage)

0.5 s
after another 0.2 s
after approx. 10 s

Landis+Gyr

4/10

Operating Behaviour (cont.)

Insulation Strength

Voltage restoration (Power Up)


Function standby 3 phases
after 4 s
Function standby 1 phase
after 5 s
Detection of energy direction and phase voltage
after 4 to 5 s

Insulation strength

Power Consumption

Protection class ll to IEC 60050-131

Power consumption per phase in voltage circuit


Phase voltage
110 V 240 V 277 V
Active power (typical)
0.8 W 1.3 W 1.5 W
Apparent power (typical)
1.1 VA 2.1 VA 2.5 VA
Power consumption per phase in current circuit
Phase current
10 A
Apparent power (typical)
0.03 VA

Environmental Influences
Temperature range
Operation
Storage

to IEC 62052-11
40 C to +70 C
40 C to +85 C

Temperature coefficient
Range
25 C to +70 C
Average value (typical)
0.012% per K
At cos=1
(from 0.05 Ib to Imax) 0.02% per K
0.03% per K
At cos=0.5 (from 0.1 Ib to Imax)
Impermeability to IEC 60529

IP 53

Electromagnetic Compatibility
Electrostatic discharges
Contact discharge
Air discharge

to IEC 61000-4-2
8 kV
15 kV

Electromagnetic RF fields
80 MHz to 2 GHz

to IEC 61000-4-3
10 and 30 V/m

Radio disturbance according to IEC/CISPR 22


class B
Burst immunity test
acc. to IEC 61000-4-4
Current and voltage circuits
4 kV
Auxiliary circuits > 40 V
2 kV
Fast transient surge test
acc. to IEC 61000-4-5
Current and voltage circuits
4 kV
Auxiliary circuits > 40 V
1 kV

Landis+Gyr

4 kV at 50 Hz during 1 min.

Impulse voltage 1.2/50 s


Current and voltage circuits
Cuxiliary circuits > 40 V

to IEC 62052-11
10 kV
6 kV
2

Calendar Clock
Calendar Type
Gregorian or Persian (Jalaali)
Accuracy

< 5 ppm

Backup time (power reserve)


With supercap
> 21 days
Charging time for 7 days backup time
24 h
Charging time for max. backup time
300 h
With battery 1
(calendar clock, display, readout)
10 years
Battery type
UM3-R6-AA
With battery 2 (calendar clock only)
10 years
Battery type
CR2032

Display
Characteristics
Type
LCD liquid crystal display
Digit size in value field
9 mm
Number of digits in value field
up to 8
Digit size in index field
8 mm
Number of digits in index field
up to 7

Inputs and Outputs


Control inputs
Control voltage US
Max. input voltage
Input current

100 to 277 VAC


320 VAC
< 2 mA ohmic at 230 VAC

Output solid state


Type
solid state relay
Voltage
12 to 277 VAC/DC
Max. current
100 mA
Max. switching frequency (pulse length 20 ms) 25 Hz
Output electromechanical
Type
electromechanical relay
Max switch voltage
277 VAC
Max. switch current
6A
Rated current
5A

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

5/10

Inputs and Outputs (cont.)


Optical test outputs
Type
Number
Meter constant

active and reactive energy


red LED
2
selectable

Communication Interface
Optical interface
to IEC 62056-21
Type
serial, asynchronous, half-duplex
Max. transmission rate
19,200 bps
Protocols
IEC 62056-21 and dlms
RS232 Interface (powered and not powered)
to DIN 61393 / DIN 66259
Type
serial, asymmetric, asynchr., bidirectional
Operating mode
intelligent or transparent
Nominal voltage
9 VDC
Maximum voltage
15 VDC
Minimum voltage
5 VDC
Max. transmission rate
38,400 bps
Protocols
IEC 62056-21 and dlms
Max. conductor length depending on
environment and connecting cable
30 m
Insulation resistance to meter 4 kVAC/50 Hz, 1 min
Creep distance
6.3 mm
RS485 Interface
to ISO-8482
Type
serial, symmetrical, half duplex
Nominal input voltage common mode range
7 to +12 VDC
Binary 1 state
difference voltage < 0.2 V
Binary 0 state
difference voltage > 0.2 V
Max. transmission rate
38,400 bps
Max. number of slaves
31
Protocols
IEC 62056-21 and dlms
Max. conductor length depending on
environment and connecting cable
1000 m
Insulation resistance to meter 4 kVAC/50 Hz, 1 min
Creep distance
6.3 mm
CS Interface
to IEC 62056-21 / DIN 66258
Type
serial, bidirectional, current interface
Nominal voltage without load
24 VDC
Max. voltage without load
30 VDC
Binary 1 state
1030 mA
Binary 0 state
2 mA
Max. transmission rate
9600 bps
Protocols
IEC 62056-21 and dlms
Insulation resistance to meter 4 kVAC/50 Hz, 1 min
Creep distance
6.3 mm

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

RS422-Interface
to ISO-8482
Type serial, symmetric, asynchronous, bidirectional
Nominal input voltage common mode range
3 to +3 VDC
Binary 1 state
difference voltage < 0.2 V
Binary 0 state
difference voltage > 0.2 V
Max. transmission rate
38,400 bps
Max. number of slaves
10
Protocols
IEC 62056-21 and dlms
Max. conductor length depending on
environment and connecting cable
1000 m
Insulation resistance to meter 4 kVAC/50 Hz, 1 min
Creep distance
6.3 mm

Weight and Dimensions


Weight

approx. 1.5 kg

External dimensions
Width
Height (with short terminal cover)
Height (with standard terminal cover)
Height (with extended hook)
Depth

177 mm
244 mm
281.5 mm
305.5 mm
75 mm

Suspension triangle
Height (with extended hook)
Height (suspension eyelet open)
Height (suspension eyelet covered)
Width
Terminal cover
Short
Standard
Long (opaque, transparent)
Standard
Standard
GSM
RCR/FTY adapter
ADP1 adapter

230 mm
206 mm
190 mm
150 mm

no free space
40 mm free space
60 mm free space
80 mm free space
110 mm free space
60 mm free space

Material
Housing
Polycarbonate, partly glass-fibre reinforced

Connections
Phase connections
Type
cage type terminals
Cross section
9 x 9 mm
Min. conductor cross section
2.5 mm2
2
Max. cross section cable
35 mm (up to 125 A)
Max. cross section strand
25 mm2 (up to 80 A)
Screw head
Pozidrive Combi No. 2
Screw dimension
M6 x 14
Screw head diameter
6.6 mm
Tightening torque
3 to 5 Nm

Landis+Gyr

6/10
RS422-Interface
Type designation
Type
Pin assignment

Connections (cont.)
RS232 Interface
Type designation
Type
Pin assignment

.02/.42/.62
RJ 12
1

RS485 Interface
Type designation
Type
Pin assignment
6
1

1
2
3
4
5
6

1
2
3
4
5
6

RS422

RS422

1
2
3
4
5
6

GND
U P (Data a)
U N (Data b)
U N (Data z)
UP (Data y)
GND

The two RJ12 jacks of the RS422-interface are looped


internally to permit connection of several meters.

.03/.43/.63/.37
RJ 12

RS232 powered
Type designation
Type
Pin assignment

c (common ground)
a (data a)
b (data b)
b
a
c

CS Interface
Type designation
Type

CTS
TxD
GND
DTR
RxD
DSR

.60/.62/.63
RJ 12

.40/.42/.43
screw type terminals

.07/.37
RJ 45
8

1
2
3
4
5
6
7
8

NC
CTS
TxD
GND
NC
RxD
NC
V+ (10 ... 14 V)

Voltage outputs U1, U2, U3, N


Type
screw type terminals
Max. current
1A
Max. voltage of control inputs
300 V

Meter Dimensions (standard terminal cover, suspension eyelet open)


6.2

281.5

206
40

26

190

75

150
177

75

The height of the suspension triangle with extended hook is 230 mm. See also User Manual.

Landis+Gyr

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

7/10
Terminal Dimensions
5

13.5

19.75 14.5 14.5 14.5 14.5 14.5 14.5 12.6

Terminal Layout

Control inputs and


output contacts

Communication
interfaces
Voltage
outputs

U2

U1

U3

optical
separation
of phases

L1

L2

L3

Phase connections

Control inputs and output contacts

Communication
interfaces
Voltage
outputs

U1

U2

U3

optical
separation
of phases

L1

L2

L3

Phase connections

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

Landis+Gyr

8/10
Type designation

ZMG

10

CR

4.

260

b.

43 S2

Network type
ZMG

3-phase 4 wire network (M-circuit)

Connection type
3

Direct connection

Accuracy class
10

Active energy class 1 (IEC), B (MID)

Measured quantities
CR
AR

Active and reactive energy


Active energy

Tariff functions
1
2
3
4

Energy rates, externally controlled


Energy rates, internally controlled with time switch (TOU)
Energy and demand rates, externally controlled
Energy and demand rates, internally controlled with time switch (TOU)

Number of control inputs / number of output contacts / special functions


000
020
060
240
260
440
041

No control inputs, no output contacts, no special functions


2 output contacts
6 output contacts
2 control inputs, 4 output contacts
2 control inputs, 6 output contacts
4 control inputs, 4 output contacts
No control inputs, 4 output contacts, 1 output relay 5A

Additional functions
0
3
4
7
a
b

None
With software events
With hardware and software events
With load profile
With load profile and software events
With load profile, hardware and software events

Interfaces 2 (Xx) and 1 (xX) (S2 = Series 2)


00 No interfaces
02 RS232
03 RS485

40 CS*
42 CS and RS232*
43 CS and RS485*

60 RS422**
62 RS422 and RS232**
63 RS422 and RS485**

07 Powered RS232***
37 RS485 and
Powered RS232***

*) only as .260x.4x or as .440x.4x


**) only as .041x.6x
***) only as .020x.07, .041x.37, .240x.37 or as .060x.37

Landis+Gyr

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

9/10

D000029744 en h E550 Series 2 ZMG310AR/CR Technical Data

Landis+Gyr

Contact:
Landis+Gyr (Europe) AG
Theilerstrasse 1
CH-6301 Zug
Switzerland
Phone: +41 41 935 6000
www.landisgyr.com

You might also like