BAsket Strainer Sizing Hayward
BAsket Strainer Sizing Hayward
BAsket Strainer Sizing Hayward
Selection Criteria
Basket Sizes Offered for Hayward simplex and Duplex Plastic Basket Strainers
Pressure Drop Correction Factors for Various Size Basket Screens
PLASTIC
STAINLESS STEEL
Correction
Correction
Perforation
Perforation
Factor
Factor
1/32"
1/16"
1/8"
3/16"
1.05
1.00
0.58
0.46
1/32"
3/64"
1/16"
5/64"
7/64"
1/8"
5/32"
3/16"
1/4"
3/8"
1/2"
0.82
0.63
0.74
0.50
0.51
0.58
0.37
0.46
0.58
0.45
0.48
STAINLESS STEEL
Mesh
Correction
Factor
20
40
60
80
100
200
325
0.79
1.01
1.20
1.16
1.20
1.09
1.22
mesh
inches microns
mesh
inches microns
3,250
1,600
750
325
250
200
180
170
160
150
140
0.0002
0.0005
0.0010
0.0016
0.0024
0.0029
0.0033
0.0035
0.0038
0.0041
0.0042
130
120
110
100
90
80
70
60
50
40
30
0.0043
0.0046
0.0051
0.0055
0.0061
0.0070
0.0078
0.0092
0.0117
0.015
0.020
6
14
25
40
62
74
85
90
97
100
108
110
118
131
149
156
179
200
238
300
385
513
Mesh
24
20
18
16
14
12
10
8
6
5
4
inches microns
0.028
0.034
0.039
0.045
0.051
0.060
0.075
0.097
0.132
0.159
0.203
718
872
1,000
1,154
1,308
1,538
1,923
2,488
3,385
4,077
5,205
Note: To calculate pressure drop through vessels using other than 1/16" perforated baskets, first calculate
the pressure drop using the listed Cv, and then multiply the result by the correction factor in the Correction
Factors chart above. See page 102 for the applicable pressure drop calculation.