ATPDraw Manual
ATPDraw Manual
ATPDraw Manual
version 3.5
for Windows 9x/NT/2000/XP
Users' Manual
Lszl Prikler,
Hans Kristian Hidalen
Preliminary Release No. 1.1
October 2002
ATPDraw
for Windows
3.5
The content of this document is identical to the SINTEF Report
No. TR F5680, but is not an official document of the SINTEF
Energy Research, Norway. It has been converted to PDF format
and made available for distribution via the secure ATP FTP
servers and Web sites, as well as via the regional EMTP-ATP
Users Groups. ATP license is required to obtain the ATPDraw
program and this manual. Conversion of this manual to other
formats and distribution on any kind of media requires explicit
permission from the authors.
www.energy.sintef.no
PREFACE
This Users' Manual documents all main features of ATPDraw version 3.5. The manuscript is
prepared by Lszl Prikler at SYSTRAN Engineering Services Ltd. in Budapest, and based on
the previous Users' Manual for ATPDraw version 1.0, SINTEF TR A4790, dated November
1998. The Reference Manual gives a summary of menu items and menu options. The Advanced
Manual covers the new features Grouping, $Parameter, line/cable-, and transformer modeling.
Finally the Application Manual is extended with several new examples.
New ATPDraw users are advised to start with the Installation and Introductory manuals.
ATPDraw is developed by SINTEF Energy Research (SEfAS). Program and documentation
development have been financed by Bonneville Power Administration, USA.
For SINTEF Energy Research Trondheim, Norway 7
th
August 2002
Hans Kr. Hidalen
project manager
SUMMARY
ATPDraw is a graphical, mouse-driven preprocessor to the ATP version of the Electromagnetic
Transients Program (EMTP) on the MS-Windows platform. The program is written in Borland
Delphi 2.0 and runs under Windows 9x/NT/2000/XP. In ATPDraw the user can construct an
electrical circuit using the mouse and selecting components from menus, then ATPDraw
generates the ATP input file in the appropriate format based on "what you see is what you get".
The simulation program ATP and plotting programs can be integrated with ATPDraw.
ATPDraw supports multiple circuit modeling that makes possible to work on more circuits
simultaneously and copy information between the circuits. All kinds of standard circuit editing
facilities (copy/paste, grouping, rotate, export/import, undo/redo) are available. In addition,
ATPDraw supports the Windows clipboard and metafile export. The circuit is stored on disk in a
single project file, which includes all the simulation objects and options needed to run the case.
The project file is in zip-compressed format that makes the file sharing with others very simple.
Most of the standard components of ATP (both single and 3-phase), as well as TACS are
supported, and in addition the user can create new objects based on MODELS or $Include (Data
Base Module). Line/Cable modeling (KCLee, PI-equivalent, Semlyen, JMarti and Noda) is also
included in ATPDraw where the user specifies the geometry and material data and has the option
to view the cross section graphically and verify the model in the frequency domain. Objects for
Harmonic Frequency Scan (HFS) have also been added. Special components support the user in
machine and transformer modeling based on the powerful Universal Machine and BCTRAN
components in ATP-EMTP.
ATPDraw supports hierarchical modeling by replacing selected group of objects with a single icon
in unlimited numbers of layers. POCKET CALCULATOR and $PARAMETER features of ATP
is also supported, allowing the user to specify a text string as input in a components' data field,
then assign numerical values to these texts strings later.
ATPDraw for Windows version 3.5 3
TABLE OF CONTENTS
Page
1. Introduction . . . ...................................................................................................................... 7
1.1 What is ATPDraw? .............................................................................................................. 9
1.2 What is ATP?..................................................................................................................... 10
1.3 Operating priciples and capabilities of ATP...................................................................... 10
1.3.1 Integrated simulation modules in ATP........................................................................ 11
1.3.2 Program capabilities .................................................................................................... 12
1.3.3 Main characteristics of plotting programs for ATP..................................................... 13
1.3.4 Typical EMTP applications......................................................................................... 15
1.3.5 Hardware requirements for ATP ................................................................................. 15
1.4 Contents of this manual...................................................................................................... 15
1.5 Manual conventions ........................................................................................................... 16
2. Installation Manual . . . ......................................................................................................... 17
2.1 ATP licencing policy.......................................................................................................... 19
2.2 How to download ATPDraw?............................................................................................ 20
2.3 Hardware requirements for ATPDraw............................................................................... 20
2.4 Program installation........................................................................................................... 20
2.5 Files and sub-folders in the ATPDraw system folder ........................................................ 21
2.5.1 Organizing the files ..................................................................................................... 22
2.5.2 Configuring ATPDraw................................................................................................ 23
2.6 Interfacing ATPDraw with other programs of the ATP-EMTP package........................... 23
2.6.1 Calling Watcom ATP and GNU MingW32 ATP from ATPDraw.............................. 25
2.6.2 Running Salford ATP from inside ATPDraw............................................................. 25
2.6.3 Calling PlotXY , PCPlot or ATP_Analyzer ................................................................ 26
2.6.4 Running TPPLOT from ATPDraw ............................................................................. 26
2.6.5 ATPDraw command line options ................................................................................ 26
2.7 How to get help? ................................................................................................................ 27
2.7.1 Help from the author of ATPDraw.............................................................................. 27
2.7.2 Help via electronic mail .............................................................................................. 27
2.7.3 Help via the ATP-EMTP-L mailing list ...................................................................... 27
2.8 Available circuit objects in ATPDraw............................................................................... 28
3. Introductory Manual . . . ....................................................................................................... 31
3.1 Operating windows ............................................................................................................ 33
3.2 Operating the mouse .......................................................................................................... 36
3.3 Edit operations ................................................................................................................... 36
3.4 Overview of working with ATPDraw................................................................................ 37
3.5 Your first circuit (Exa_1.adp) ............................................................................................ 38
3.5.1 Building the circuit ...................................................................................................... 39
3.5.2 Storing the project file on disk .................................................................................... 49
3.5.3 Creating the ATP input file ......................................................................................... 49
3.5.4 Running the simulation ............................................................................................... 51
3.6 Three phase circuits (Exa_2.adp)....................................................................................... 52
4 ATPDraw for Windows version 3.5
4. Reference Manual . . . ........................................................................................................... 55
4.1 Main window..................................................................................................................... 57
4.2 Main menu......................................................................................................................... 58
4.2.1 File .............................................................................................................................. 58
4.2.2 Edit.............................................................................................................................. 61
4.2.3 View............................................................................................................................ 66
4.2.4 ATP............................................................................................................................. 70
4.2.5 Objects ........................................................................................................................ 79
4.2.6 Tools ........................................................................................................................... 85
4.2.7 Window....................................................................................................................... 92
4.2.8 Help............................................................................................................................. 93
4.3 Shortcut menu.................................................................................................................... 96
4.4 Component selection menu ............................................................................................... 96
4.5 Component dialog box ...................................................................................................... 97
4.6 Node dialog box .............................................................................................................. 100
4.7 Open Probe dialog box .................................................................................................... 102
4.8 Open Group dialog box ................................................................................................... 102
4.9 Circuit objects in ATPDraw............................................................................................ 103
4.9.1 Probes & 3-phase...................................................................................................... 105
4.9.2 Branch Linear............................................................................................................ 106
4.9.3 Branch Nonlinear ...................................................................................................... 108
4.9.4 Lines/Cables.............................................................................................................. 109
4.9.5 Switches .................................................................................................................... 112
4.9.6 Sources...................................................................................................................... 113
4.9.7 Machines................................................................................................................... 114
4.9.8 Transformers............................................................................................................. 115
4.9.9 MODELS.................................................................................................................. 116
4.9.10 TACS..................................................................................................................... 120
4.9.11 User Specified........................................................................................................ 124
4.9.12 Frequency comp..................................................................................................... 125
4.9.13 Standard Component... .......................................................................................... 125
5. Advanced Manual . . . ........................................................................................................ 127
5.1 Grouping: a new ATPDraw feature for multilevel modeling.......................................... 129
5.1.1 Grouping nonlinear objects....................................................................................... 133
5.2 Support of new ATP features $Parameters and Pocket Calculator ................................. 135
5.3 Using the integrated LCC object for line/cable modeling............................................... 136
5.3.1 Model and Data page settings for Overhead Lines ................................................... 139
5.3.2 Model and Data page settings for Single Core Cable systems.................................. 142
5.3.3 Model and Data page settings for Enclosing Pipe type cables.................................. 144
5.4 Verification of the Line/Cable model performance......................................................... 145
5.5 Using MODELS simulation language............................................................................. 148
5.5.1 Creating the model file.............................................................................................. 149
5.5.2 Creating a new MODELS object .............................................................................. 150
5.5.3 Recording internal MODELS variables.................................................................... 154
5.6 BCTRAN support in ATPDraw...................................................................................... 154
5.7 Non-standard component dialog boxes ........................................................................... 158
5.7.1 Saturable 3-phase transformer .................................................................................. 158
5.7.2 Universal machines................................................................................................... 160
ATPDraw for Windows version 3.5 5
5.7.3 Statistic/systematic switch......................................................................................... 164
5.7.4 Harmonic source........................................................................................................ 165
5.8 Creating new circuit objects in ATPDraw....................................................................... 166
5.8.1 Creating a 6-phase rectifier bridge ............................................................................ 166
5.8.2 Creating a user specified, nonlinear transformer model............................................ 171
6. Application Manual . . . ...................................................................................................... 175
6.1 Switching in 500 kV system (Exa_3.adp)........................................................................ 177
6.2 TACS controlled induction machine (Exa_4.adp)........................................................... 180
6.3 Usage of the Library and Reference objects (Exa_5.adp)................................................ 184
6.4 Modeling an HVDC station (Exa_6.adp and Exa_6g.adp).............................................. 186
6.5 Switching studies using JMarti LCC objects ................................................................... 190
6.5.1 JMarti model of a 500 kV line (Exa_7.adp).............................................................. 190
6.5.2 JMarti model of a 750 kV line................................................................................... 196
6.5.3 Line to ground fault and fault tripping transients (Exa_7a.adp) ............................... 198
6.6 Using MODELS controlled switches (DC68.DAT) (Exa_8.adp).................................... 201
6.7 Lightning overvoltage study in a 400 kV substation (Exa_9.adp)................................... 207
6.8 Simulating transformer inrush current transients............................................................. 213
6.8.1 Energization of a 400/132/18 kV auto-transformer (Exa_10.adp)............................ 213
6.8.2 Energization of a 132/15 kV generator step-up transformer (Exa_11.adp) .............. 219
6.9 Switching overvoltage studies with statistical approach (Exa_12.adp)........................... 223
6.9.1 Setting program options for the statistical simulation............................................... 223
6.9.2 Results of the statistical study ................................................................................... 224
7. Appendix . . . . . . . . . . . ...................................................................................................... 229
7.1 ATPDraw.ini file settings ................................................................................................ 230
7.1.1 [ATPDraw]................................................................................................................ 230
7.1.2 [Preferences].............................................................................................................. 231
7.1.3 [Directories]............................................................................................................... 231
7.1.4 [View Options] .......................................................................................................... 233
7.1.5 [ATP Settings]........................................................................................................... 233
7.1.6 [1024x768] ................................................................................................................ 235
7.1.7 [Reload] ..................................................................................................................... 235
7.1.8 [Objects] .................................................................................................................... 235
7.2 PFC simulations in ATPDraw.......................................................................................... 236
7.3 References........................................................................................................................ 241
7.4 Index................................................................................................................................. 243
7
1. Introduction . . .
. . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Introduction
ATPDraw for Windows version 3.5 9
1.1 What is ATPDraw?
ATPDraw for Windows is a graphical, mouse-driven preprocessor to the ATP version of the
Electromagnetic Transients Program (EMTP). In ATPDraw the user can construct the digital
model of the circuit to be simulated using the mouse and selecting predefined components from an
extensive palette, interactively. Then ATPDraw generates the input file for the ATP simulation in
the appropriate format based on "what you see is what you get". Circuit node naming is
administrated by ATPDraw, thus the user needs to give a name only to nodes having special
interest.
ATPDraw has a standard Windows layout and offers a large Windows help file system. All kinds
of standard circuit editing facilities (copy/paste, grouping, rotate, export/import, undo/redo) are
available. Other facilities in ATPDraw are: built-in editor for ATP-file editing, text viewer for
displaying the output LIS-file of ATP, automatic LIS-file checking with special trigger strings to
detect simulation errors, support of Windows clipboard and metafile export. ATPDraw supports
multiple circuit modeling that makes possible to work on more circuits simultaneously and copy
information between the circuits.
Most of the standard components of ATP (both single and 3-phase), as well as TACS are
supported, and in addition the user can create new objects based on MODELS or $INCLUDE
(Data Base Module). Line/Cable modeling (KCLee, PI-equivalent, Semlyen, JMarti and Noda) is
also included in ATPDraw where the user specifies the geometry and material data and has the
option to view the cross section graphically and verify the model in the frequency domain. Objects
for Harmonic Frequency Scan (HFS) have also been added. Special objects help the user in
machine and transformer modeling including the powerful UNIVERSAL MACHINE and BCTRAN
features of ATP.
ATPDraw supports hierarchical modeling to replace a selected group of objects with a single icon
in unlimited numbers of layers. $PARAMETER feature of ATP is also implemented, allowing the
user to specify a text string as input in a components' data field, then assign numerical values to
these texts strings later. The circuit is stored on disk in a single project file, which includes all the
simulation objects and options needed to run the case. The project file is in zip-compressed format
that makes the file sharing with others very simple.
ATPDraw is most valuable to new users of ATP-EMTP and is an excellent tool for educational
purposes. However, the possibility of multi-layer modeling makes ATPDraw a powerful front-end
processor for professionals in analysis of electric power system transients, as well.
Version 2.0 and above of ATPDraw for 9x/NTx/2000/XP Windows platforms are written in
Borland Delphi 2.0. Development of 16-bit versions for Windows 3.1/95 stopped with the
launching of ATPDraw 1.0. A version 3.6 compiled with Delphi 6.0 is also available.
ATPDraw is a trademark and copyrighted by 1998-2001 SINTEF Energy Research, Norway.
Program developer is Dr. Hans Kristian Hidalen at SINTEF Energy Research in Trondheim,
Norway, with Dahl Data Design in Norway as a programming sub-contractor and SYSTRAN
Engineering Services in Hungary as a sub-contractor for program documentation. Program
development has been financed by Bonneville Power Administration in Portland, Oregon, USA,
with Pacific Engineering Corporation as project coordinator.
Introduction
10 ATPDraw for Windows version 3.5
The ATPDraw program is royalty free and can be downloaded free of charge from several Internet
sites. The on-line help of ATPDraw and the present program documentation includes third-party
proprietary information of, thus ATP licensing is mandatory prior to get permission to download
the program and documentation from the Internet, or to receive ATP related materials from others.
1.2 What is ATP?
The Alternative Transients Program (ATP) is considered to be one of the most widely used
universal program system for digital simulation of transient phenomena of electromagnetic as well
as electromechanical nature in electric power systems. With this digital program, complex
networks and control systems of arbitrary structure can be simulated. ATP has extensive modeling
capabilities and additional important features besides the computation of transients.
The Electromagnetic Transients Program (EMTP) was developed in the public domain at the
Bonneville Power Administration (BPA) of Portland, Oregon prior to the commercial initiative in
1984 by the EMTP Development Coordination Group and the Electric Power Research Institute
(EPRI) of Palo Alto, California. The birth of ATP dates to early in 1984, when Drs. Meyer and
Liu did not approve of proposed commercialization of BPA's EMTP and Dr. Meyer, using his own
personal time, started a new program from a copy of BPA's public-domain EMTP. Since then the
ATP program has been continuously developed through international contributions by Drs. W.
Scott Meyer and Tsu-huei Liu, the co-Chairmen of the Canadian/American EMTP User Group.
Several experts around the world have been contributing to EMTP starting in 1975 and later to
ATP in close cooperation with program developers in Portland, USA.
Whereas BPA work on EMTP remains in the public domain by U.S. law, ATP is not in the public
domain and licensing is required before access to proprietary materials is granted. Licensing is,
however, available free of all charge to anyone in the world who has not participated voluntarily in
the sale or attempted sale of any electromagnetic transients program, (hereafter called "EMTP
commerce").
1.3 Operating priciples and capabilities of ATP
1
The ATP program predicts variables of interest within electric power networks as functions of
time, typically initiated by some disturbances. Basically, trapezoidal rule of integration is used to
solve the differential equations of system components in the time domain. Non-zero initial
conditions can be determined either automatically by a steady-state phasor solution or they can be
entered by the user for simpler components.
ATP has many models including rotating machines, transformers, surge arresters, transmission
lines and cables. Interfacing capability to the program modules TACS (Transient Analysis of
Control Systems) and MODELS (a simulation language) enables modeling of control systems and
components with nonlinear characteristics such as arcs and corona. Dynamic systems without any
electrical network can also be simulated using TACS and MODELS control system modeling.
Symmetrical or unsymmetrical disturbances are allowed, such as faults, lightning surges and
several kind of switching operations including commutation of valves. Frequency-domain
harmonic analysis using harmonic current injection method (HARMONIC FREQUENCY SCAN)
1
Source: WWW.EMTP.ORG
Introduction
ATPDraw for Windows version 3.5 11
and calculation of the frequency response of phasor networks using FREQUENCY SCAN feature
is also supported. The model-library of ATP at present consists of the following components:
Uncoupled and coupled linear, lumped R,L,C elements.
Transmission lines and cables with distributed and frequency-dependent parameters.
Nonlinear resistances and inductances, hysteretic inductor, time-varying resistance,
TACS/MODELS controlled resistance.
Components with nonlinearities: transformers including saturation and hysteresis, surge
arresters (gapless and with gap), arcs.
Ordinary switches, time-dependent and voltage-dependent switches, statistical switching
(Monte-Carlo studies).
Valves (diodes, thyristors, triacs), TACS/MODELS controlled switches.
Analytical sources: step, ramp, sinusoidal, exponential surge functions, TACS/MODELS
defined sources.
Rotating machines: 3-phase synchronous machine, universal machine model.
User-defined electrical components that include MODELS interaction
1.3.1 Integrated simulation modules in ATP
MODELS in ATP is a general-purpose description language supported by an extensive set of
simulation tools for the representation and study of time-variant systems.
The description of each model is enabled using free-format, keyword-driven syntax of
local context and that is largely self-documenting.
MODELS in ATP allows the description of arbitrary user-defined control and circuit
components, providing a simple interface for connecting other programs/models to ATP.
As a general-purpose programmable tool, MODELS can be used for processing simulation
results either in the frequency domain or in the time domain.
TACS is a simulation module for time-domain analysis of control systems. It was originally
developed for the simulation of HVDC converter controls. For TACS, a block diagram
representation of control systems is used. TACS can be used for the simulation of
HVDC converter controls
Excitation systems of synchronous machines
power electronics and drives
electric arcs (circuit breaker and fault arcs).
Interface between electrical network and TACS is established by exchange of signals such as node
voltage, switch current, switch status, time-varying resistance, voltage- and current sources.
Supporting routines are integrated utilities inside the program that support the users in
conversion between manufacturers' data format and the one required by the program, or to
calculate electrical parameters of lines and cables from geometrical and material data. Supporting
modules in ATP are:
Introduction
12 ATPDraw for Windows version 3.5
Calculation of electrical parameters of overhead lines and cables using program modules
LINE CONSTANTS, CABLE CONSTANTS and CABLE PARAMETERS.
Generation of frequency-dependent line model input data (Semlyen, J.Marti, Noda line
models).
Calculation of model data for transformers (XFORMER, BCTRAN).
Saturation and hysteresis curve conversion.
Data Base Modularization (for $INCLUDE usage).
Fig. 1.1 - Supporting routines in ATP.
1.3.2 Program capabilities
ATP-EMTP tables are dimensioned dynamically at the start of execution to satisfy the needs of
users and their hardware (e.g., RAM). No absolute limits have ever been observed, and the
standard version has limits that average more than 20 times default table sizes. Today, the largest
simulations are being performed using Intel-based PC's. The following table shows maximum
limits for standard program distribution.
Busses 6000 Sources 900
Branches 10000 Nonlinear elements 2250
Switches 1200 Synchronous machines 90
Source: www.emtp.org
Introduction
ATPDraw for Windows version 3.5 13
1.3.3 Main characteristics of plotting programs for ATP
These post-processors are interfaced with ATP via disk files and their main function is to display
the results of a time- or frequency domain simulation. ATP simulation data are stored in a file
having extension .pl4, and it can be processed either off-line, or on-line. The latter (i.e. to
display results while the simulation proceeds) is available only if the operating system provides
concurrent PL4-file access for ATP and the postprocessor program.
Fig. 1.2 Plotting programs for ATP.
TPPLOT program has been written under Salford FORTRAN that requires a DOS extender.
DBOS is incompatible with NT series of MS-Windows, thus TPPLOT cannot be used under NT,
2000 or XP. TPPLOT detects automatically the PL4-file format and reads almost all file formats
created by any PC version of ATP. TPPLOT has a semi-graphical user interface and nearly all
commands can be executed by the mouse. The program supports up to 20 curves per plot, plots
versus time as well as X-Y plots, factor and offset, automatic or manual axis scaling and labeling.
The curves are drawn using solid lines with different colors and user can mark each curve with
different characters. Visually redundant data points are eliminated on the screen. Screen plots can
be exported in various text-, bitmap or vector graphics file formats including Postscript, HPGL
and COMTRADE. The program not only writes but also reads data files in COMTRADE format.
Simple mathematical manipulations are also supported, as well as FFT analysis and bar chart plots
for harmonics.
Developer: Dr. W. Scott Meyer, [email protected], USA.
Licensing: Distributed at no cost to the licensed ATP users.
Distribution: EEUG annual CD distribution, EEUG, JAUG secure Web sites.
GTPPLOT is a plotting program for processing PL4 output of ATP. It is compiled with the GNU
FORTRAN, and makes use of the graphical package DISLIN. The program is available for DOS-
djgpp extender, Windows 32, and Linux. GTPPLOT can read widenn, formatted PL4-files
(FMTPL4 = 10Fnn.), C-like binary files, unformatted files, COMTRADE and ASCII data files.
GTPPLOT is able to process graphics files with up to 1000000 points and up to 1000 variables.
The program can plot up to 20 curves end export the graphics in nine different formats: HP-GL,
CGM, WMF, PCX, PostScript, PNG, WMF, JAVA and GNUPLOT. For FS and HFS runs the
plot can be bar charts. The data can be exported as widenn PL4, COMTRADE, Matlab, MathCad
and Mathematica files. Furthermore, the program calculates lot of Power Quality Indexes from
data, can be used for FOURIER analysis, turbine shaft loss of life estimation. Various simple math
operations with variables, as integration, derivation, RMS, power, energy, I2T are also supported.
ATP-EMTP
(TPBIG.EXE)
TPPLOT WPCPLOT
HFSPlot DspATP32 GTPPLOT ATP Analyzer
PL42mat PlotXY DisplayNT
PL42mcad
.PL4, .PS
file
Introduction
14 ATPDraw for Windows version 3.5
GTPPLOT can be used to generate KIZILCAY F-DEPENDENT elements from FREQUENCY
SCAN PL4 output, as well. GTPPLOT has no graphical interface, the user must use the keyboard
for all the input commands.
Developer: Mr. Orlando P. Hevia, [email protected], Santa-Fe, Argentina.
Licensing: Distributed at no cost to the licensed ATP users.
Distribution: EEUG annual CD distribution, EEUG, JAUG, MTU secure FTP/Web sites.
PlotXY is a WIN32 plotting program originally designed for ATP-EMTP. The program is mainly
designed to make, as easy and fast as possible, line plots in Microsoft Windows environments. It
is also able to perform some post-processing on the plotted curves: algebraic operations,
computation of the Fourier series coefficients. The program has an easy-to use graphical user
interface, and the 32 bit code provides very fast operation. Up to 3 PL4 or ADF files can be
simultaneously held in memory for easy comparison of different data and up to 8 curves per plots
versus time, or X-Y plots are allowed. The program has a clever automatic axis scaling capability
and able to make plots with two independent vertical axes and provides easy tools for factors,
offsets and zoom support, and a graphical cursor to see values in numerical format. Screen plots
can be exported as Windows Metafile via win32 clipboard.
Developer: Dr. Massimo Ceraolo, [email protected], University of Pisa, Italy.
Licensing: acknowledgeware. Distributed at no cost to the licensed ATP users. If user keeps it beyond the 30-day
trial period, he/she must send an acknowledgement letter to the developer.
Distribution: EEUG annual CD distribution, EEUG, JAUG and MTU secure FTP sites.
PCPLOT was steadily developed and improved until 1997 using Borland Turbo Pascal under
MS-DOS platforms. The program can read PL4-file types of unformatted, C-like binary and
formatted files. PCPLOT can display maximum 4 curves with 16000 plot points per curve. The
maximum number of plot variables stored in the plot file is limited up to 100. The program
supports three different plot types: time function (results of the simulations), X-Y plot (one
variable against another), frequency-response (results of "FREQUENCY SCAN" cases). The
values of the plotted variables can be displayed by means of a vertical marker line. Different type
of curves (e.g. currents and voltages) can be mixed in the same plot by defining scaling factors and
offset. The curves are drawn using solid lines with different colors and user can mark each curve
with different characters at the desired positions. Visually redundant data points on plots are
eliminated to accelerate the drawing speed. Screen plots can be sent to disk file in HP-GL format.
Developer: Prof. Dr. Mustafa Kizilcay ([email protected]), Germany.
Licensing: freely available without separate licensing to all ATP users.
Distribution: EEUG annual CD distribution, EEUG, JAUG secure FTP/Web sites.
WPCPlot is a graphical output program for ATP-EMTP running under Microsoft Windows
95/98/NT/2000. The program is capable of processing PL4-files of C-like and formatted types
Maximum 6 variables in the same diagram are allowed. Zooming, redraw features and a readout
facility to obtain instantaneous values of plotted curves are provided. Screen plots can be copied
to clipboard or save as color or monochrome bitmap image file.
Developer: Prof. Dr. Mustafa Kizilcay, [email protected], Deniz Celikag, [email protected].
Licensing: available only for EEUG members at present.
Main characteristics of other postprocessors for ATP are summarized in [6].
Introduction
ATPDraw for Windows version 3.5 15
1.3.4 Typical EMTP applications
ATP-EMTP is used world-wide for switching and lightning surge analysis, insulation coordination
and shaft torsional oscillation studies, protective relay modeling, harmonic and power quality
studies, HVDC and FACTS modeling. Typical EMTP studies are:
Lightning overvoltage studies
Switching transients and faults
Statistical and systematic overvoltage studies
Very fast transients in GIS and groundings
Machine modeling
Transient stability, motor startup
Shaft torsional oscillations
Transformer and shunt reactor/capacitor switching
Ferroresonance
Power electronic applications
Circuit breaker duty (electric arc), current chopping
FACTS devices: STATCOM, SVC, UPFC, TCSC modeling
Harmonic analysis, network resonances
Protection device testing
1.3.5 Hardware requirements for ATP
ATP is available for most Intel based PC platforms under DOS, Windows 3.1/9x/NT, OS/2, Linux
and for other computers, too (e.g., Digital Unix and VMS, Apple Macs, etc.). Most users,
including program developers, use Intel Pentium-based PCs with MS-Windows 9x/NT. A
standard Pentium PC configuration with min. 128 MB RAM, hard disk (20 MB free space) and
VGA graphics is sufficient to execute ATP under MS-Windows. Most popular program versions
are at present:
MS-Windows 9x/NT/2000/XP: 32-bit GNU-Mingw32 and Watcom ATP
MS-DOS, MS-Windows 3.x/95/98: 32-bit Salford ATP (requires DBOS/486)
Linux: GNU version of ATP
1.4 Contents of this manual
This Users Manual of ATPDraw for Windows 3.5 contains five parts:
INSTALLATION MANUAL
How to obtain the ATP license
How to download ATPDraw
How to install ATPDraw
Hardware requirements
How to configure your system
How to use ATPDraw as operating shell for other ATP simulations
How to communicate with other users and program developers
Introduction
16 ATPDraw for Windows version 3.5
INTRODUCTORY MANUAL
How to create a circuit in ATPDraw
Operating windows
Your first circuit
Three-phase circuits
REFERENCE MANUAL
Reference of main menu items and program options
Reference of the Component, Node and Group dialog boxes
Reference of ATPDraw circuit objects
ADVANCED MANUAL
How to create new circuit objects in ATPDraw
How to use new features: Grouping and $PARAMETERS
How to use MODELS and $Include in ATPDraw?
How to use the integrated LCC object for line/cable modeling
How to use the integrated BCTRAN object for transformer modeling
Referencing four non-standard Component dialog boxes:
Saturable 3-phase transformer
Univeral Machines
Statistical switches
Harmonic source
APPLICATION MANUAL
Simple line energization studies
Pulse width modulated induction machine
Creating libraries of circuits and user specified libraries
HVDC station, rectifier/converter modeling
Shunt capacitor bank switching
Line/cable constant application examples
Single-phase to ground fault and fault tripping transients
Electric arc simulation using MODELS controlled switches
Lightning studies, arrester modeling
Transformer energization, inrush currents
Line energization studies with statistical approach
1.5 Manual conventions
The following typographical conventions are used in this manual:
Italic: Menus in ATPDraw
E.g.: Select Edit | Rotate : Select Rotate command in the pop-up menu Edit.
Courier 9 - 10: Data files.
E.g.: Listing of ATP input files, MODELS code, etc.
Description of menu options in component dialog boxes.
Courier 11 - 12: Data code and file names.
E.g.: Give the file the name HVDC_6.LIB and store it in the \USP directory.
The \USP directory is a directory under the main directory of ATPDraw.
Courier 12 : Commands on the DOS prompt.
E.g.: C:\TMP>setup: Type the command setup at C:\TMP>.
17
2. Installation Manual . . .
. . . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Installation Manual
ATPDraw for Windows version 3.5 19
2.1 ATP licencing policy
ATPDraw and the present documentation includes ATP proprietary information, thus ATP
licensing is mandatory prior to get permission to download the program from the Internet. ATP
license is free of all charge for all who have not engaged in EMTP commerce, and it can be
obtained from the Canadian/American EMTP User Group, or an authorized regional users group.
In general, organizational licensing is preferred over licensing of individuals. Undergraduate
students are not licensed personally. If ATP usage is to be organizational rather than personal (i.e.,
if ATP materials are to be used by, in, for, or on behalf of, a company, university, etc.), the
licensee must certify that the organization has not participated in EMTP commerce -- nor has any
employee, contractor, or other agent who would be granted access to ATP materials. Once one is
licensed, he/she is authorized to download ATP materials from the secure Internet sites or obtain
them from a similarly licensed user, or order these materials from the regional user groups.
At present the Canadian/American, European and the Japanese user groups accepts ATP license
applications via the Internet. Interested parties are requested to visit the on-line licensing page at
www.emtp.org, fill-in and submit the appropriate web-form. Potential users of other continents
must follow the licensing procedure of their regional EMTP user group. Geographical location of
ATP-EMTP user groups and contact information details are shown below:
S
o
u
r
c
e
:
w
w
w
.
e
m
t
p
.
o
r
g
Fig. 2.1 - Location of ATP-EMTP user groups.
Name E-mail and WWW address
Canadian/American EMTP User Group [email protected]
European EMTP-ATP Users Group (EEUG) [email protected], www.eeug.org
Japanese ATP User Group (JAUG) [email protected], www.jaug.jp/~atp/index-e.htm
Latin American EMTP User Group (CLAUE) [email protected], www.furnas.gov.br/atp
Argentinian EMTP User Group (CAUE) [email protected]
http://iitree.ing.unlp.edu.ar/estudios/caue/caue.html
Australian EMTP User Group (AEUG) [email protected]
Korean EMTP User Group (KEUG) [email protected]
Republic of China EMTPUser Group [email protected]
Indian EMTP User Group (IEUG) [email protected]
South African ATP User Group (SAAUG) [email protected], www.ee.wits.ac.za/~atp
Chapter 2.7.3 of the Installation Manual gives further information about the ATP related Internet
resources.
Installation Manual
20 ATPDraw for Windows version 3.5
2.2 How to download ATPDraw?
ATP licensing is mandatory prior to receiving any materials. Following the license agreement
approval by an authorized user group, you are eligible to use the ATP program and all ATP related
tools, like ATPDraw and this manual. There are different sources of obtaining ATPDraw and
additional ATP related tools and program manuals:
Order ATP materials from the Canandian/American EMTP User Group
(http://www.emtp.org/canamfl.html#ger) in Oregon, USA, or from the
European EMTP-ATP Users Group Association (http://www.eeug.org).
Download from secure, password-protected web site of the European EMTP-ATP Users
Group Association (http://www.eeug.org/files/secret)
Download from secure, password-protected web sites of the Japanese ATP User Group
(http://alpha.kisarazu.ac.jp/~secure, or
http://pels.pwr.eng.osaka-u.ac.jp/~atp/restricted)
Download from the password-protected FTP file server at Michigan Technological
University in Houghton (USA) (http://www.ee.mtu.edu/atp/ftp.html).
Please contact the regional user group to acquire passwords to access these sites. Passwords are
changed regularly!
2.3 Hardware requirements for ATPDraw
ATPDraw requires moderate CPU power and memory. It runs even on a slow Pentium 100
MHz/32 MB PC with acceptable speed. A standard Pentium PC configuration with min. 128 MB
RAM (256 MB under Windows 2000 and XP), 100 MB free hard disk space and XVGA graphics
is sufficient to execute ATPDraw and other ATP programs.
2.4 Program installation
The /atpdraw subfolder under the above secure servers contains a zip-compressed archive
atpdraw3x.zip, a short installation guide and the latest patch file (if any). Following a
successful download of the distribution kit, perform the next operations:
1) Copy the atpdraw3x.zip file into a TEMP directory and unzip it.
2) Run the program setup.exe. The installation process will be assisted by a standard Install
Shield Wizard.
3) Specify a destination directory for ATPDraw when prompted. It is wise to avoid using
directory name including "space". E.g. C:\Program Files is not recommended. Install
the program into a root directory, e.g. D:\ATPDraw3. If you are not allowed to install
programs outside Program Files, let the Wizzard to install ATPDraw into this folder.
Note that in such a case special care is needed when setting environmental variables for
ATP.
4) The installation process will be completed after creating a new shortcut for ATPDraw under
Start | Programs | ATPDraw. When you start ATPDraw3.x first time it will create the
necessary system sub-folders /ATP, /BCT, /GRP, /LCC, /MOD, /Project under the main
program folder. If you install ATPDraw first time skip points 5) and 6).
Installation Manual
ATPDraw for Windows version 3.5 21
5) Copy the existing files in the /USP, /MOD and /Project folders of the earlier ATPDraw
version into the new folders. Even if you do not have your own USP objects it is strongly
advised to create an empty /USP sub-folder. Lack of it, projects with embedded USP
objects received from another user will not run properly. Standard objects are stored in a
single file called ATPDraw.scl, thus no separate /SUP and /TAC folders are needed in
version 3 and above.
6) Copy ATPDraw.ini of the previous version (2.x or 3.x) into the system folder of the new
ATPDraw installation. This way you can preserve the ATP | Edit Commands and many other
program settings if you modified default values earlier.
7) Download the latest patch file called patchxv3.zip (if exists on the server), then unzip it
and simply overwrite the existing files in the ATPDraw system folder with the newer ones
received in the patch file.
The program installation will create a directory structure as shown next. ATPdraw can be
uninstalled in the standard manner using Windows' uninstaller (Start menu | Settings | Control
Panel | Add/Remove programs).
PROJECT <DIR> 10-22-01 9:54p Project
LCC <DIR> 10-22-01 9:54p lcc
ATP <DIR> 10-22-01 9:58p Atp
USP <DIR> 04-29-02 8:11a Usp
GRP <DIR> 10-22-01 9:58p Grp
MOD <DIR> 10-22-01 9:58p Mod
BCT <DIR> 03-22-02 12:42p Bct
ATPDRAW CNT 3,091 04-11-02 3:23p ATPDraw.CNT
ATPDRAW EXE 1,182,208 04-29-02 10:58a Atpdraw.exe
ATPDRAW HLP 421,824 04-11-02 3:24p ATPDraw.hlp
ATPDRAW SCL 203,378 04-25-02 10:08p ATPDraw.scl
_ISREG32 DLL 24,576 02-07-96 8.07a _ISREG32.dll
DeIsL1 ISU 2,863 06-08-02 10.11a DeIsL1.isu
RUNAF BAT 71 10-22-01 10:22p runAF.bat
RUNATP_G BAT 90 10-22-01 10:56p runATP_G.bat
RUNATP_S BAT 108 10-22-01 10:55p runATP_S.bat
RUNATP_W BAT 90 10-22-01 10:54p runATP_W.bat
The files _ISREG32.dll and DeIsL1.isu are created by the install shield for uninstall purposes.
2.5 Files and sub-folders in the ATPDraw system folder
To use ATPDraw four files are required: ATPDraw.exe, ATPDraw.scl (standard component
library), ATPDraw.cnt (help content), and ATPDraw.hlp (help file). Besides, the user can
create his own components (user specified or models) and include files.
Project file: When the user saves a circuit the work is stored in the project file (*.adp = atpdraw
project). This file contains the circuit with all data and graphical representation and in addition, all
files describing user specified components (support, line/cable, trafo, model and library files). The
project file is compressed by a public domain Pkzip routine and can in fact be opened with any
version of WinZip. It may occur that a virus checker inaccurately recognizes the project files as
virus infected and quarantine them when you send or receive such a file in e-mail attachments. If it
happens, the local virus filtering database should be modified to allow the exchange of project
files. Contact IT staff!
Installation Manual
22 ATPDraw for Windows version 3.5
Support file: All components require a support file. This file describes the type of component, the
nodes (phases, position, identity) and data (default value, limits, parameter flag, number of digits,
identity), the default icon (41x41 pixels) and the help file. The version 3.x of the support file also
contains options for specifications of the data format in ATP but this is not used yet. The support
files for standard components are zipped together in the file ATPDraw.scl (standard component
library) and this file is required together with the project file to open and run a project. The
support files can be edited inside ATPDraw in the Objects menu. The default icon can also be
modified by using the built in icon editor. New objects can be created by specifying new support
files.
ATP file: This file is produced by ATPDraw and used as input to ATP simulation. The .atp files
are located in the \ATP sub- directory and can be edited with any text-processors, including
ATPDraws own Text Editor. It is advised, however only for experts to modify this file manually.
Line/cable file: A line or cable is described by an .alc file (atpdraw line/cable). This binary file
contains the line-, cable constants or cable parameter data. The alc data are used by ATPDraw to
run ATP and create an electrical model of a line or cable.
BCTRAN file: A BCTRAN (Transformer) component is described in a .bct file. This binary file
contains the input data required for the supporting routine BCTRAN of ATP-EMTP. The .bct
data are used by ATPDraw to run ATP and create an electrical transformer model.
Model file: A model is described in a model file (.mod). This text file starts with MODEL
<name> and ends with ENDMODEL. The <name> must be equal to the model file name. The
model file is included directly in the final ATP input data file. It is recommended to store the
models file in the \MOD sub-directory.
Include files: User Specified Components are described in a library file (.lib). This text file has
a pre-defined format (as specified in by the Data Base Module of ATP) and contains a header
describing the positions of the parameters, further the ATP cards and finally a trailer containing
the specification of the parameters. The library file is included in the ATP input file with $Include.
The line/cable components also have a library file, created by ATPDraw. Some nonlinear
components or saturable transformers might also have an include file for the nonlinear
characteristic.
2.5.1 Organizing the files
When ATPDraw opens a project the included files are stored on disk preferable where they were
located when the project was stored, or if this directory does not exists, in the default directories
specified under Tools | Options/Directories. In both cases existing files are not overwritten
without noticing the user. The time stamp of the disk file and the file in the project is compared
and a warning like File on disk is older/newer than the stored project file will appear. It is
important that the user replies to these messages carefully. To avoid conflicts the user is advised
not to use the same name for several different user created models.
When the project is stored the disk files are not deleted (except for group support-files). Thus, as
times goes by the number of files on disk grows. It is the user's responsibility to tidy up the
directories. Remember: All required files are stored in the project and only the files you modify
yourself outside a project need to be kept. All other files (sup, lib, mod, alc, bct) can be deleted.
Installation Manual
ATPDraw for Windows version 3.5 23
2.5.2 Configuring ATPDraw
The ATPDraw.ini file contains customizable program options. Generally, default settings meet
most of the users requirements. When required, the .ini file can either be modified via Tools |
Options menu of the program, or by using a text editor. Default values and supported options are
described in the Appendix part of this Manual.
2.6 Interfacing ATPDraw with other programs of the ATP-EMTP package
The ATP-EMTP simulation package consists of various separate programs which are
communicating with each other via disk files: i.e. the output of pre-processors are used as input
for the main program TPBIG.EXE, while the product of the simulation can be used as input for
plotting programs. The main program itself is often used as pre-processor (e.g. for LINE
CONSTANTS, CABLE CONSTANTS, BCTRAN or DATA BASE MODULE runs), and the punch-file
products in that cases can be re-used as input in a subsequent run via $Include. Taking that the
structure of the program components is rather difficult, a user shell to supervise the execution of
separate programs and input/output flows has a great advantage.
The new Edit Commandsfeature of ATPDraw supports to extend the command set under the
ATP menu by integrating optional user commands, such as Run ATP (file) / Run PlotXY / Run
TPPlot / Run PCPlot / / Run ATP_Analyzer / Run ACC / Run PL42mat, etc. This option makes
possible to use the ATPDraw program as a graphical operating environment and execute the other
ATP programs in a user friendly way as shown in Fig. 2.2.
Fig. 2.2 - Interaction between ATPDraw and the other ATP programs.
ATPDraw
ASCII text
editor
ATP
(TPBIG.EXE)
TPPLOT
PCPLOT
DisplayNT
DspATP32
PL42mat
ATP
Analyzer
.PL4
.PS
GTPPLOT
.ATP
input file
.ADP
project file
.ALC
line data
USP
library
.PCH
library
*.ATP
PlotXY
*.PL4
*.PS
Data
fl
Information
fl
LCC BCT
Installation Manual
24 ATPDraw for Windows version 3.5
Fig. 2.3 - The Edit Commands dialog box. Fig. 2.4 - User specified commands.
In the Edit Commands dialog box of Fig. 2.3 the user can specify the name of a .bat or an .exe
file and the name of a file, which then will be sent as parameter (e.g. ATP.bat <current
.atp file> or PlotXY.exe <current .pl4 file>) when ATPDraw executes these
external programs. The Name field specifies the name of the command, while the Command and
Parameter fields specify the name of the file to be executed and the optional parameter. Selecting
Current ATP radio button, the full name of the ATPDraw project in the current circuit window
with extension .atp will be sent as parameter. When selecting the File button, the ATPDraw
performs a file open dialog box before executing the command, where the user can select a file,
which is then will be passed as parameter. The commands are inserted in the ATP menu
dynamically, when the user activates the Update button as shown above.
Fig. 2.5 - Default settings to run ATP and Armafit.
The default batch command that is executed when the user selects run ATP or (F2) is specified
under the Tools | Options /Preferences tab as shown in Fig. 2.5. Checking the contents of this
batch file is very important following the program installation, because ATPDraw needs to be able
Installation Manual
ATPDraw for Windows version 3.5 25
to execute ATP for several reasons automatically, and this has always performed by activating this
command. It must be noted that ATPDraw has no connection with the main program of ATP
(TPBIG.EXE) at the code level or via DLLs. The run ATP menu item simply executes the
external commands specified by the user. So it is always the users responsibility to install ATP
properly and provide these external .bat files in correct format.
2.6.1 Calling Watcom ATP and GNU MingW32 ATP from ATPDraw
Proper execution of the Watcom and GNU version of ATP requires that environmental variables
WATDIR or GNUDIR be set correctly
1
, i.e. SET WATDIR=Drive:\Path\WatcomATPdir\
in the AUTOEXEC.BAT if you use Win9x, or set these parameters under My Computer |
Properties dialog if Windows NT/2000 or XP is used. The RunATP_W.BAT and RunATP_G.BAT
commands are created by the install program of ATPDraw. These batch files has a single line:
%watdir%tpbig.exe both %1 * -r
%gnudir%tpbig.exe both %1 s r
If an additional W or G is seen at the end of the ATP executable (TPBIG.EXE) in your
installation, you have to modify the RunATP_*.BAT accordingly. You may find inserting some
additional commands into these batch files, as well. E.g.:
echo off
%gnudir%tpbigg.exe both %1 s -r
pause -- waits for user interaction before the DOS box of ATP closed (optional)
del dum*.bin -- delete temporary files created by ATP (optional)
del *.tmp
del ..\*.tmp
2.6.2 Running Salford ATP from inside ATPDraw
Note that Salford ATP can be used under Win9x only! To ensure smooth interaction between
ATPDraw, DBOS and Salford ATP, it is recommended to add the DBOS directory to the search
PATH and specify an ATPDIR environmental variable in the AUTOEXEC.BAT file, i.e. SET
ATPDIR=Drive:\Path\SalfordATPdir\. The RunATP_S.BAT is created by the install
program of ATPDraw and this batch files has a single line:
run77.exe %atpdir%tpbig.exe /PARAMS both %1 * -r
If an additional S is seen at the end of the ATP executable (TPBIG.EXE) in your installation,
you have to modify the RunATP_S.BAT accordingly. You may find inserting some optional
commands into the batch file, as well. E.g.:
echo off
run77.exe %atpdir%tpbigs.exe /PARAMS both %1 * -r
pause -- waits for user interaction before the DOS box of ATP closed (optional)
del dum*.bin -- delete temporary files created by ATP (optional)
del *.tmp
del ..\*.tmp
1 The Install Shield wizard of the annual ATP program ditribution for EEUG members makes these settings
automatically.
Installation Manual
26 ATPDraw for Windows version 3.5
RunATP_S.BAT properties should be set as shown next:
Program:
Cmd line: Drive:\Path\RunATP_S.BAT
Batch file: DBOS_ON.BAT
Run: Normal Window
Close on exit:
Screen Usage: Window
Because Salford ATP is running under DBOS, a single line batch file DBOS_ON.BAT must be
executed before TPBIG.EXE is launched. The corresponding single line command of the
DBOS_ON.BAT file referenced in the Properties | Batch file should be as follows:
Drive:\dbos3_5\dbos /page 800000 {800000 limits DBOS to use 8MB extended memory}
2.6.3 Calling PlotXY , PCPlot or ATP_Analyzer
After creating the Run PlotXY and/or Run PCPLOT commands using the ATP | Edit Commands
submenu selet Current PL4 as Parameter and Browse to select the name of the executable disk
file of the corresponding application. Update button adds the new Runcommand to the ATP
menu.
2.6.4 Running TPPLOT from ATPDraw
TPPLOT is also a DBOS application and it does not run under Windows NT/2000/XP. Settings
are very similar to that of in section 2.6.2 for Salford ATP. When creating the Run TPPLOT
command using the ATP | Edit Commands submenu, select None as Parameter and
Drive:\Path\TPPLOT.BAT as Command. The TPPLOT.BAT has a single line run77
%atpdir%tpp.exe. Properties are almost identical as in section 2.6.2, with Screen as
exception that should be set full-screen. Moreover, it is suggested to modify the settings at the end
of the TPPLOT.BEG file as shown below:
C @LAB2 -- comment it out or copy the LAB2 file into your ATPDraw directory
FILE ATP\*.PL4 -- add these two commands at the end of the file
CHOICE
2.6.5 ATPDraw command line options
Command lines are rarely used under Windows operating systems, nevertheless ATPDraw
provides an option to load one or more project files at program start. In the example below, the
project file my1st.adp and my2nd.adp will be loaded automatically and displayed in separate
circuit windows.
C:\ATPDRAW>atpdraw c:\atpdraw\cir\my1st.adp c:\cir\my2nd.adp
In MS-Windows environment you can use this property to create a shortcuts on the desktop for the
ATPDraw project files. For instance, click with the right mouse button on an empty space of the
desktop and select New | Shortcut, then browse and select ATPDraw.exe. Click right on the
just created icon and select Properties. Specify the Target: properties of the new shortcut as the
full path of the program including the project file name (e.g. c:\atpdraw\atpdraw.exe
Installation Manual
ATPDraw for Windows version 3.5 27
mycir.adp), and the Start in: parameter as the project file directory (e.g.
c:\atpdraw\project).
2.7 How to get help?
ATPDraw offers a standard Windows help file system. This file provides help on all windows and
menus in ATPDraw and assists in building up a circuit. Several links between help pages and a
relatively large index register for searching text or phrases are also available. A Help button is
attached to all circuit objects, which shows a brief overview of the meaning of each parameter.
Modification and extension of these help files with users own remarks are also possible using the
built in Help Editor in the Tools menu.
2.7.1 Help from the author of ATPDraw
The author of the program is also available for questions from ATPDraw users, but is only
responsible to Bonneville Power Administration and Pacific Engineering Corporation.
Address: Dr. Hans Kr. Hidalen
SINTEF Energy Research
7465 Trondheim - NORWAY
http://www.energy.sintef.no
E-mail: [email protected]
Phone: + 47 73594225
Fax: + 47 73594279
The ATPDraw Web page is maintained at address:
http://www.ee.mtu.edu/atp/atpdraw/ATPDraw.html
2.7.2 Help via electronic mail
Electronic mail is the most known feature of the Internet. By this way, anyone who has an account
on a computer connected to the Internet can send messages to others. For ATP users this service
provides an easy, efficient and very fast way of communication with other users all over the world,
including program developers, regional user group representatives, or the author of ATPDraw.
2.7.3 Help via the ATP-EMTP-L mailing list
The listserver is an E-mail remailer program, which rebroadcasts incoming messages to all
subscribers to the list. The European EMTP-ATP Users Group Association in cooperation with
the German Research Network (DFN) and the University of Applied Sciences of Osnabrck,
Germany operates a free electronic mailing list using address [email protected]. This
LISTSERV mailing list is for ATP-related announcements, questions, answers, etc. The ATP-
EMTP-L list is moderated and only licensed ATP users are entitled to subscribe by means of the
authorized persons of the regional ATP-EMTP user groups, who checks first the license status of
the applicant, then send a subscription request to the list operator. To learn more about the
subscription procedure and the operation rules of this very active mailing list, please visit the
www.emtp.org web site.
Installation Manual
28 ATPDraw for Windows version 3.5
After your name has been added to the list, you can post messages. To do this, you simply send
e-mail to [email protected]. Your message then will be submitted to moderators, who
decide whether or not to accept it. The task of moderators is maintenance of the quality of
communication and discussion. The language of communication is English. Messages written in
any other language are not accepted. The author of each submission must be clearly identified.
This includes name, organizational affiliation, and location. Attachments, especially encoded files,
are not allowed. They can be forwarded later to interested persons by private e-mail. Any
subscriber who sends a message to this mailing list gives up his right to confidentiality. This is
regardless of the message's possible declaration in auto-attached legal disclaimers, which are
removed by moderators. Subscribers of the ATP-EMTP-L mailing list must fulfill the ATP license
requirements. Specifically, they are forbidden to disclose to non-licensed persons ATP
information that is received from this mail service.
2.8 Available circuit objects in ATPDraw
At the time of writing of this manual ATPDraw's standard component library contains 194 circuit
object support files. These 194 files support more than 100 of ATP's components, i.e. many
components have several versions in ATPDraw.
Standard components
Linear branches:
Resistor, Inductor, Capacitor, RLC
RLC 3-phase, symmetric and non symmetric
Inductor and capacitor with initial condition
Non-linear branches:
1-phase nonlinear R and L components
Current dependent resistor, type 99
Type-93, 96 and 98 nonlinear inductors including initial flux linkage conditions
Time dependent resistor, type 97
Single and 3-phase MOV type 92 exponential resistor
TACS controlled resistor
Line models:
Lumped, PI-equivalents (type 1, 2...) and RL coupled components (type 51, 52...)
RL symmetric, sequence input. 3 and 6-phase
Distributed lines of constant parameters, Transposed (Clarke), untransposed (KCLee)
LCC objects: Bergeron, nominal PI, JMarti, Semlyen and Noda models
Switches:
Time controlled. 1 and 3-phase
Voltage controlled
Diode, thyristor, triac (type 11 switches)
Simple TACS controlled switch of type 13
Measuring switches
Statistic and systematic switches, independent and master-slave
Sources:
DC, type 11
Ramp, type 12
Two-slope ramp, type 13
AC source. 1 and 3 phase, type 14
Double-exponential surge source, type 15
Installation Manual
ATPDraw for Windows version 3.5 29
Heidler-type source, type 15
Standler-type source, type 15
CIGR-type source, type 15
TACS source, type 60
Ungrounded DC source, type 11+18
Ungrounded AC source, type 14+18
Machines:
Synchronous machine type 59 with no control, or max. 8 TACS controls
Universal machines. Universal machines (type 1, 3, 4, 6, and 8)
Transformers:
Single-phase and 3-phase ideal transformer. Type 18 source
Single-phase saturable transformer
3-phase, 2- or 3 winding saturable transformer
3-phase 2-winding saturable transformer, 3-leg core type of high homopolar reluctance
BCTRAN. 1-3 phases, 2-3 windings. Auto-transformers, Y-, and D- connections
MODELS
Input/output and Data variables of MODELS code are recognized automatically
Corresponding support file for the model is automatically created
Type 94 (Thevenin, Norton, Iterative) objects are supported
TACS
Coupling to circuit object helps in hybrid simulations
Transfer functions: General Laplace transfer function with or without limits
Integral, Derivative, first order Low and High Pass transfer functions
Fortran statements: General Fortran statement (single line expression)
Simplified Math statements or Logical operators
Sources: DC, AC, PULSE, RAMP.
TACS devices. All devices except type-55
Initial condition for TACS objects (type-77)
User specified objects
Users can create new objects using Data Base Modularization and $Include
Frequency components
Harmonic sources for Harmonic Frequency Scan studies
Single and 3-phase frequency dependent loads in CIGR format
Single phase RLC element with frequency dependent parameters
31
3. Introductory Manual . . .
. . . . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Introductory Manual
ATPDraw for Windows version 3.5 33
This part of the users manual gives the basic information on how to get started with ATPDraw.
The Introductory Manual starts with the explanation of how to operate windows and mouse in
ATPDraw. The manual shows how to build a circuit step by step, starting from scratch. Then
special considerations concerning three phase circuits are outlined.
3.1 Operating windows
ATPDraw has a standard Windows user interface. This chapter explains some of the basic
functionalities of the Main menu and the Component selection menu of the Main window.
Fig. 3.1 - The Main window and the floating Component selection menu.
The ATPDraw for Windows program is functionally similar to the DOS version [1]. The
Component selection menu is hidden, however, but appears immediately when you click the right
mouse in the open area of the Circuit window.
Fig. 3.1 shows the main window of ATPDraw containing two open circuit windows. ATPDraw
supports multiple documents and offers the user to work on several circuits simultaneously along
with the facility to copy information between the circuits. The size of the circuit window is much
larger than the actual screen, as is indicated by the scroll bars of each circuit window. The Main
window consists of the following parts:
Main menu Tool bar icons Component
tool bar
Header,
project file
name
Circuit
windows
Circuit
comments
Windows
standard buttons
Circuit
map
Scroll
bars
Current action
mode
Component
selection menu
Status bar with
menu option hints
Introductory Manual
34 ATPDraw for Windows version 3.5
Header + Frame:
As a standard Windows element, it contains the system menu on the left side, a header text and
minimize, maximize, exit buttons on the right side. The main window is resizable.
System menu: Contains possible window actions: Close, Resize, Restore, Move, Minimize,
Maximize or Resize and Next. The last one exists only if multiple circuit
windows are open.
Header text: The header text is the program name in case of the main window and the
current circuit file name in case of the circuit window(s). To move a window,
click in the header text field, hold down and drag.
Minimize button: A click on this button will iconize the main window.
Maximize button: A click on this button will maximize the window. The maximize button will
then be replaced with a resize button. One more click on this button will bring
the window back to its previous size.
Corners: Click on the corner, hold down and drag to resize the window.
Main menu:
The main menu provides access to all the functions offered by ATPDraw. The menu items are
explained in detail in the Reference part of this Manual:
File: Load and save circuit files, start a new one, import/export circuit files, create
postscript and metafile/bitmap files, print the current circuit and exit.
Edit: Circuit editing: copy/paste/delete/duplicate/flip/rotate, select, move label, copy
graphics to clipboard and undo/redo etc.
View: Tool bar, status bar and comment line on/off, zoom, refresh and view options.
ATP: Run ATP, make and edit ATP-file, view the LIS-file, make node names, ATP-file
settings (miscellaneous, file format, file sorting etc.), assign data to variables for
$PARAMETER usage and specify RECORD for MODELS output requests.
Objects: Edit support files (default values, min/max limits, icon and help file), create new files
for MODELS and User Specified Objects.
Tools: Icon editor, help file editor, text editor, setting of various program options.
Window: Arrange the circuit windows and show/hide the Map window.
Help: About box and Windows help file system.
Circuit window:
The circuit is built up in this window. The circuit window is the container of circuit objects. From
the File menu you can load circuit objects from disk or simply create an empty window to start
building a new circuit. Circuit objects include standard ATP components, user specified elements,
MODELS and TACS components, connections and relations. To move around in the circuit, you
can use the window scrollbars, or drag the view rectangle of the Map window to another position.
Component selection menu:
This menu pops-up immediately when you click with the right mouse button in an empty space of
the Circuit window. In this menu you select the circuit objects. After selecting an object in one of
the sub-menus, the object is drawn in the circuit window in marked and moveable mode.
Circuit comments:
A comment line below the circuit window shows a user defined circuit comment text.
MAP window:
This window gives a bird's eye view of the entire circuit. The size of a circuit is 5000x5000 pixels
(screen points); much larger than your screen would normally support. Consequently, the Circuit
window displays only a small portion of the circuit. The actual circuit window is represented by a
Introductory Manual
ATPDraw for Windows version 3.5 35
rectangle in the Map window.
Press and hold down the left mouse button in the map rectangle to move around in the map. When
you release the mouse button, the circuit window displays the part of the circuit defined by the
new rectangle size and position. The map window is a stay-on-top window, meaning that it will
always be displayed on the top of other windows. You can show or hide the map selecting the
Map Window option in the Window menu, or pressing M character,
Status bar - Action mode field:
The current action mode of the active circuit window is displayed in the status bar at the bottom of
the main window, when the Status Bar option is activated in the View menu. ATPDraw can be in
various action modes. The normal mode of operation is MODE : EDIT , in which new objects are
selected and data are given to objects. Drawing connections brings ATPDraw into CONN.END
mode and so on. ATPDraws possible action modes are:
EDIT The normal mode.
CONN.END After a click on a node, the action mode turns into CONN.END indicating that
the program is waiting for a left mouse click to set the end-point of a new
connection. To cancel drawing a connection, click the right mouse button or
press the ESC key to return to MODE : EDIT.
MOVE LABEL Indicates a text label move. Clicking the left mouse button on a text label, then
holding it down and dragging it enables you to move the label to a new
position. If the text label is overlapped by a component icon, the text label can
be moved using Move Label in the Edit menu. Then the action mode turns into
MOVE LABEL. Releasing the mouse at the new text label location, the action
mode returns to MODE : EDIT.
GROUP Indicates region selection. Double clicking the left mouse button in an empty
space of the active circuit window enables you to draw a polygon shaped
region. To end the selection, click the right mouse button. Any objects within
the selected region are marked then for selection. To cancel region selection,
press the Esc key.
INFO.START Indicates the start of a relation when TACS | Draw relation is activated in the
selection menu. Clicking the left mouse button on a component node or on the
end-point of another relation will initiate the drawing of a new relation.
Relations are used to visualize information flow into FORTRAN statements
and are drawn as blue connections, but do not influence the connections of
components.
INFO.END Indicates the end of a relation. The program is waiting for a left mouse button
click to set the end-point of the new relation. To cancel drawing relation, click
the right mouse button or press the Esc key.
Status bar - Modified and Hints field:
The middle field of the status bar is used to display the Modified state of the active circuit. As
soon as you alter the circuit (moving a label, deleting a connection, inserting a new component,
etc.), the text Modified appears, indicating that the circuit should be saved before exit. The field
will be empty when you save the circuit or undo all modifications. The rightmost field of the
status bar displays the menu option hints.
Introductory Manual
36 ATPDraw for Windows version 3.5
3.2 Operating the mouse
This chapter contains a summary of the various actions taken dependent on mouse operations. The
left mouse button is generally used for selecting objects or connecting nodes; the right mouse
button is used for specification of object or node properties.
Left simple click:
On object: Selects object or connection.
If the Shift key is pressed, the object is added to the current selection group.
On object node: Begins to draw a connection.
Move the mouse to the end node, left click to place, right to cancel.
In open area of the circuit window: Unselects object.
Right simple click:
In open area of the circuit window:
Opens the Component selection menu, or
Cancels the connection made if connection draw mode has been activated earlier.
On object node:
Pops-up the Node data window.
On unselected object: Opens the Component dialog box.
If Shift key is pressed simultaneously: opens the circuit window Shortcut menu.
On selected object(s): Rotates object(s).
If Shift key is pressed simultaneously: opens the circuit window Shortcut menu.
Left click and hold:
On object: Moves the object or selected group of objects.
On node: Resizes connection (it is often necessary to select connection first).
In open area of the circuit window: Draws a rectangle for group selection.
Objects inside the rectangle are becoming member of the group when
the mouse button is released.
Left double click:
On object node:
Performs the Node data window.
On selected or unselected single object:
Performs the Component dialog box.
On selected group of objects:
Performs an Open Group dialog box.
In open area of the circuit window:
Starts the group selection facility. Click left to create an enclosing polygon, click right
to close. Objects inside the polygon become a group.
3.3 Edit operations
ATPDraw offers the most common edit operations like copy, paste, duplicate, rotate and delete.
The edit options operate on a single object or on a group of objects. Objects must be selected
before any edit operations can be performed. Selected objects can also be exported to a disk file
and any circuit files can be imported into another circuit.
Introductory Manual
ATPDraw for Windows version 3.5 37
Tool Shortcut key Equivalent in menus
UNDO Alt + BkSp Edit | Undo
REDO Shft+Alt+BkSp Edit | Redo
Cut/Copy Ctrl+X/Ctrl+C Edit | Cut/Copy
Paste Ctrl+V Edit | Paste
Duplicate Ctrl+D Edit | Duplicate
Select/All Ctrl+A Edit | Select All
Select/Polyg. Ctrl+P Edit | Select Group (or left double click in open space)
Select/Type Ctrl+T Edit | Select Type/Group number
Label Ctrl+L Edit | Move Label
Rotate Ctrl+R Edit | Rotate (or right click)
Rubber Band Ctrl+B Edit | Rubber Bands
Edit Group/Circuit Ctrl+G/Ctrl+H Edit | Edit Group/Circuit (one layer down or up)
Zoom In/Out + / - View | Zoom In / Out
Zoom window Z View | Zoom (pups-up zoom window)
Refresh R View | Refresh (redraw the circuit)
3.4 Overview of working with ATPDraw
After selecting a component in the Component selection menu the new circuit object appears in
the middle of the circuit window enclosed by a rectangle. Click on it with the left mouse button to
move, or the right button to rotate, finally click in the open space to unselect and place the object.
To select and move an object, simply press and hold down the left mouse button on the object
while moving the mouse. Release the button and click in an empty area to unselect and confirm its
new position. The object is then moved to the nearest grid point (known as gridsnapping). If two
or more components overlap as a consequence of a move operation, you are given a warning
message and can choose to proceed or cancel the operation.
Selecting a group of objects for moving can be done in three ways: Holding down the Shift key
while left clicking on an object. Pressing and holding down the left mouse button in an empty area
enables the user to drag a rectangular outline around the objects he wants to select. And finally,
double-clicking the left mouse button in an empty area enables the definition of a polygon-shaped
region by repeatedly clicking the left mouse button in the circuit window. To close the region,
click the right mouse button. Objects that are defined to fall within the indicated region or
rectangle are added to the selected objects group. For components this means that the centre point
of a component icon must lie within the defined region or rectangle. For connections and relations
the region or rectangle must surround both end-points. To move the selected group of objects,
press and hold down the left mouse button inside the group while moving the mouse. Unselect and
confirm the new position by clicking in an empty area. Any overlapping components will produce
a warning. To move objects outside of the visible part of the circuit, use the window scrollbars or
the view rectangle in the map window. Any selected objects or group will follow the window to
its new position. Objects or a group can be rotated by clicking the right mouse button inside the
selected object or group. Other object manipulation functions, such as undo/redo and clipboard
options can be found in the Edit menu. Additionally, the most frequently used object manipulation
functions can be accessed by holding down the Shift key while clicking with the right mouse
button on an object or on a selected group of objects. This will display and activate the circuit
window shortcut menu.
Introductory Manual
38 ATPDraw for Windows version 3.5
Components and component nodes can be opened for editing by a right-click (or left double-click)
on an unselected component or node. Either the Node data, Component or Open Probe dialog box
will appear, allowing the user to change component or node attributes and characteristics. The
Component dialog box has the same layout for most circuit objects. In this window the user must
specify the required component data. The number of DATA and NODES menu fields are the only
difference between input windows for standard objects. The nonlinear branch components have a
Characteristic page too, in addition to the normal Attributes page, where the nonlinear
characteristics and some include file options can be specified.
Selecting a single component and press the Crtl+F1 key combination, the component specific
help is displayed. When double-clicking on a selected group of objects, the Open Group dialog
box will appear, allowing the user to change attributes common to all components in that group,
such as group number, hide and lock state. Default component attributes are stored in support
files. Access to create and customize support files is provided by the Objects menu.
Components are connected if their nodes overlap or if a connection is drawn between the nodes.
To draw a connection between nodes, click on a node with the left mouse button. A line is drawn
between that node and the mouse cursor. Click the left mouse button again to place the connection
(clicking the right button cancels the operation). The gridsnap facility helps overlapping the nodes.
Connected nodes are given the same name by the Make Names and Make File options in the ATP
menu. Nodes can be attached along a connection as well as at connection end-points. A
connection should not unintentionally cross other nodes (what you see is what you get). A warning
for node naming appears during the ATP-file creation if a connection exists between nodes of
different names, or if the same name has been given to unconnected nodes. Connections can be
selected as any other objects. To resize a connection, click on its end-point with the left mouse
button, hold down and drag. If several connections share the same node, the desired connection to
resize must be selected first. Selected connection nodes are marked with squares at both ends of
the selection rectangle.
Relations are used to visualize information flow into Fortran statements and are drawn as blue
connections, but have no influence on components connectivity. Relations are drawn in the same
way as drawing a short circuit connection between nodes, except that you have to select the TACS
| Draw relation option in the component selection menu to start the relation drawing. You can
then draw multiple relations until you click the right mouse button or press Esc key.
3.5 Your first circuit (Exa_1.adp)
This chapter describes how to use ATPDraw step by step. As an example, composing the circuit
file of a single-phase rectifire bridge (see Fig. 3.2) is presented. Reading this tutorial carefully, you
will be proficient in the use of the most important ATPDraw functions, such as:
How to select and assemble components?
How to perform edit operations and give data to components?
How to give node names, draw connections and specify grounding?
How to create the ATP input file and perform the simulation?
Introductory Manual
ATPDraw for Windows version 3.5 39
Fig. 3.2 Single-phase rectifier bridge.
Fig. 3.3 Your first circuit (Exa_1.adp).
The circuit is a single-phase rectifier bridge, supplied by a 120 V
rms
, 60 Hz source. The source
inductance is 1 mH in parallel with a damping resistor of 300 W. The snubber circuits across the
rectifying diodes have a resistance of 33 W and a capacitance of 1 mF. The smoothing capacitor is
1000 mF and the load resistor is 20 W. The example has been taken from [2], exercise 1.
The units given in Fig. 3.2 are based on settings of Xopt and Copt equal to zero as will be
explained later.
The circuit in Fig. 3.3 has been chosen since its construction involves the most commonly used
edit operations.
3.5.1 Building the circuit
Most parts of the building process will be demonstrated in this chapter, along with the explanation
of correcting possible drawing errors. The normal mode of operation is MODE : EDIT. You must
always be in this mode to be able to select and specify data to objects. To return to EDIT from
other modes, press Esc.
3.5.1.1 Starting to create a new circuit
Selecting the New command in the File menu or pressing the new (empty) page symbol in the
Component Toolbar, a new circuit window will be created.
3.5.1.2 Source
First, an AC source is selected from the floating Component selection menu, which appears with a
right mouse click on open area of the circuit window. Fig. 3.4 shows how to select a 1-phase
sinusoidal voltage source (Sources | AC type 14) using the mouse.
Introductory Manual
40 ATPDraw for Windows version 3.5
Fig. 3.4 - Selecting an AC source.
After you have clicked in the AC type 14 field, the selected source appears in the circuit window
enclosed by a rectangle.
Click on it with the left mouse button, hold down and drag it to a desired position.
Then click with the left mouse button on open space to place it. The AC object is
redrawn in red color as an indication that no data have been given to the object.
Next select the source inductance as shown in Fig. 3.5:
Fig. 3.5 - Selecting an inductor.
After you have clicked in the Inductor field, the selected inductor appears in the circuit window
enclosed by a rectangle (from version 3.2 an optional, parallel damping resistance is included,
specify data Kp=0 to remove it). Click on it with the left mouse button, hold down and drag it to a
position shown in Fig. 3.6:
Click on the white space with the left mouse button to place the inductor (the
enclosing rectangle disappears). A grid snap facility helps you to place the
inductor in the correct position. The component position is rounded to the
nearest 10
th
pixel. (The included parallel resistor is shown in a dotted style.)
The inductor in Fig. 3.6 should be placed so that the node of the inductor touches the source.
Objects having overlapping node dots will automatically be connected.
The next figure shows a situation where the inductor has been misplaced. In this situation the
objects are disconnected. To correct this, a connection could be drawn between the objects as will
be explained later. In this example you are supposed to place the inductor so that its left node
Fig. 3.6
Introductory Manual
ATPDraw for Windows version 3.5 41
overlaps the AC source node. To move the inductor, follow the instructions given in Fig. 3.7.
Click on the object with the left mouse button, hold down and drag it to
the proper position, then click on white space.
Fig. 3.7 - Error!
When you have placed the inductor, you can add the damping resistance (really directly included
from version 3.2). After you have clicked in the Resistor field of the component selection menu, a
resistor icon appears enclosed by a rectangle. Click on it with the left mouse button, hold down
and drag it to a position shown in Fig. 3.8. Click in open space to place/unselect it.
This resistor is supposed to be parallel with the inductor and connections,
which ensure this will be drawn later. The resistor in Fig. 3.8 would also be
recognized as in parallel with the inductor, if it had been placed in a position
completely overlapping the inductor. This tricky way is not recommended
however, since the readability of the drawing is strongly reduced.
Fig. 3.8
We want to measure the source current flowing into the diode bridge. To be able to do so, you can
add a measuring switch. A special multi-phase current probe is available for such measurements in
ATPDraw. When using this object, you are requested to specify the number of phases and in
which phases the current should be measured. Select the probe as shown in Fig. 3.9.
Fig. 3.9 - Selecting a current measuring probe.
After you have clicked in the Probe Curr. field, the selected probe
appears in the circuit window enclosed by a rectangle. Click on it with
the left mouse button, hold down and drag it to a position shown in the
figure, then place it.
At this stage of the building process, it is time to draw some connections in the circuit diagram. To
draw a connection you just click the left mouse button on a node, release the button and move the
mouse. The cursor style now changes to a pointing hand and a line is drawn between the starting
position and the current mouse position (the action mode now is MODE : CONN.END indicating
that the program is waiting for the end point of the connection). Click with the left mouse button
again to place the connection or click with the right button to cancel the starting point.
Two connection drawings are required to parallel connecting the source inductance and the
damping resistor as shown below. The connections are always drawn with node dots if the Node
dots check box is selected in the View | Options menu.
Click left Click left Click left Click left
Release + move Release + move
Introductory Manual
42 ATPDraw for Windows version 3.5
The last object we want to introduce in the source part of the circuit is a voltage measuring probe,
which results in an output request for the node voltage in the ATP input file. The voltage sensor
can be selected via the Probe & 3-phase | Probe Volt in the component selection menu (see Fig.
3.9). The probe is drawn in the middle part of the circuit window in marked and moveable mode.
Use the left mouse button to drag and place the object as shown on the
figure to the left. When you place an object by clicking on open area of the
circuit window, you will sometimes receive a warning message as shown in
Fig. 3.10.
This message appears if a center of one of the permanent objects is
inside the enclosing polygon of a marked object (or more general; a
group of objects). This is to prevent unintentional object overlap if
the left mouse button were pressed while moving the object.
Fig. 3.10 - Prevent object overlap.
If you click on No, the object not placed but continues to be selected and you can move it further.
Normally it is OK to click on Yes. If you change your mind later, the Edit | UNDO option provides
an easy way to return to an earlier version of the circuit.
The circuit objects used in the circuit so far were drawn in red color. This tells you that no data
have been given to these objects. You can give data to objects at any time during the building
process. We will now give data to the objects in the source part of the rectifier. To do so: simple
click with the right mouse button (or double click with the left button) on an object. If you right
click on the AC source icon, a window as shown in Fig. 3.11 appears.
Fig. 3.11 - Component dialog box of the single-phase sinusoidal source.
Introductory Manual
ATPDraw for Windows version 3.5 43
Data values shown in Fig. 3.11 refer to the circuit parameters of Fig. 3.2. The name of the
numerical fields is identical with that of used by the ATP Rule Book [3] for an AC source. This
AC source has 7 input data and one node. Click on the HELP button to load the on-line help if you
are unsure about the meaning of parameters. Specify data as shown in Fig. 3.11. Here
U/I = 0 results in voltage source with default label U,
U/I = -1 results in a current source with label I.
The node names can not be specified in this window. Click OK to close the window and update
the object values. Click on Cancel to just quit the window.
After you have given data to the AC source and closed the window (note how the object layout
changes when you exit the window), proceed to the other objects. Repeat the procedure explained
above to give data to the resistor and to the inductor by calling the Component dialog box of the
objects. To do so: click with the right mouse button on the resistor and inductor icon, respectively.
The probe objects have different input window than other objects.
To open the voltage or current probe input window, click on its
icon with the right mouse button. In this window, you can select
the number of phases of the probe and which phases to monitor.
In this single-phase example, default values (no. of phases=1,
monitored phase=A) of both voltage and current probes should be
selected, as shown in Fig. 3.12
Fig. 3.12 - Open probe dialog box.
3.5.1.3 Diode bridge
In this process, you will learn how to use some editing options like rotate, group, duplicate and
paste. Since the diode bridge consists of four equal branches, you do not need to build all of them
from scratch. First, you select a diode from the selection menu as shown in Fig. 3.13. After you
have clicked on Diode (type 11) the diode appears in the circuit window enclosed by a rectangle.
The diode has to be rotated so click the right
mouse button or select Edit in the main menu and
click on Rotate. The diode is now rotated 90 deg.
counter clock-wise. Click on the diode with the
left mouse button, hold down and drag to the
position shown in Fig. 3.14.
Fig. 3.13 - Selecting a diode.
Fig. 3.14
Click with the left mouse button on empty area to place the diode.
Remember the grid snap facility and the overlap warning.
Next, you select the snubber circuit across the diode. In this example
the snubber circuit is a resistor and a capacitor in series. Select an RLC
object from the component selection menu (Fig. 3.5).
Introductory Manual
44 ATPDraw for Windows version 3.5
Click on the selected RLC branch with the right mouse button to rotate, then click with the left
button, hold down and drag the RLC branch to be in parallel with the diode. Click on the left
mouse button to place.
The idea is further to copy the diode and the RLC branch, but before doing so, it is wise to give
data to them (since the data are kept when copied). A simple click on the RLC or diode icon with
the right mouse button activates the component dialog box to give data to objects.
Again, an explanation of the input parameters is given in a help file. Press the HELP button to see
this help file. The numerical values of the diode are all zero, meaning that the diode is ideal and is
open during the steady state. The RLC branch in Fig. 3.14 has been given a resistance of 33 W and
a capacitance of 1 mF.
You have now given data to the diode and the RLC branch and instead of repeating the process
four times, you can use the copy facility. First, you have to select a group of components. This can
be done by selecting Edit | Select group field in the main menu or with a double click with the left
mouse button on an empty space of the Circuit window. Then cursor style changes to a pointing
hand and the action mode is EDIT : GROUP. The process is then to click with the left mouse
button to create a corner in a fence and to click the right button to enclose the fence (polygon). All
components having their center inside the fence are included in the group.
Alternative way of group selection is to draw a rectangle around the objects by a left mouse click
and hold at the upper-left corner of the desired rectangle, and moving thereafter to the lower-right
corner. Objects inside the rectangle become a group when the mouse button is released.
You can follow the procedure shown in Fig. 3.15.
Fig. 3.15 - Drawing a polygon: First double click on white space, click the left mouse button at
each corner of the polygon, then click the right button to enclose the polygon.
The group created in Fig. 3.15 can be copied/rotated etc. like a single object. Now we want to
duplicate this group. Click on the main menu Edit field and choose Duplicate or press the Ctrl+D
shortcut key. The selected group is copied to the clipboard and pasted in the same operation. The
old group is redrawn in normal mode and the copy is drawn in the top of the original.
The fencing polygon is now a rectangle. The pasted group is moveable, so you can click on it with
the left mouse button, hold down and drag to a desired position. Click the left mouse button on
open space to put the group in the position shown in Fig. 3.16.
Fig. 3.16 - Move a group.
Only the enclosing polygon is drawn during a move
operation. The objects are drawn when the mouse button is
released. If you misplaced the group you can mark it again
with Edit | Select group. Undo and Redo facilities are also
available on the main menu Edit.
Introductory Manual
ATPDraw for Windows version 3.5 45
You can now paste a second copy of the diode/RLC group into the circuit. Since the duplicate
facility has already copied the group to the clipboard, you can just select the Paste option from the
Edit menu by using the mouse or pressing Ctrl+V, or selecting the Paste icon from the Toolbar.
The pasted group is drawn on top of the original one enclosed by a rectangle. Click on this group
with the left mouse button, hold down and drag it to a position shown in Fig. 3.17.
Fig. 3.17 Fig. 3.18
As part of the connection between the rectifier bridge and the load a small resistor is included in
Fig. 3.2. The resistor is included to demonstrate the option of using a small resistor for current
measurement purposes.
Select a resistor in the component selection menu, then click on the resistor with the left mouse
button, hold down and drag it to a desired position as shown in Fig. 3.18. You must place the
resistor precisely, because the next step is to connect the top nodes of the diode bridge with the
resistor.
Before doing so first, give data to this resistor opening the component dialog box by a right-click
on the resistor. Specify data value RES= 0.01 W and set Output to 1-Current to get current output
in the subsequent ATP run. Having closed the component dialog box a small I
symbol appears on
the top-left side of the resistor indicating the current output request (if not check View | Options).
Now you can start to connect the diode bridge and the resistor together. The procedure is to first
click with the left mouse button on a starting node, as shown in Fig. 3.19. The cursor style now
changes to a pointing hand and the action mode is MODE : CONN.START. Then release the
mouse button and move the mouse (a rubber band is drawn from the starting point to the current
cursor position). To place a connection, click on the left mouse button again. Click on the right
button or press Esc to cancel the connection make operation.
The connection draw in Fig. 3.19 picks up intermediate nodes so all the five nodes will be
connected together. In this way, ATPDraw suits the requirement: What you see is what you get
and the amount of required connections are significantly reduced.
Fig. 3.19 - Click left button. Release + move, then click left button to place the connection.
If you made a mistake in the connection drawing process, you can correct the error easily, because
connections are editable (copy/move/rotate) as any other objects. If you would like to
correct/modify a misplaced connection, click on it with the left mouse button. After this selection,
Introductory Manual
46 ATPDraw for Windows version 3.5
the connection is enclosed by a rectangle and two squares replace node dots at the end of the line.
To move the connection, click on an internal point of it using the left mouse button, then hold
down and move, and release the mouse at the correct position. To reposition a connection, click
on the node squares with the left button and stretch the connection as illustrated in Fig. 3.20:
Fig. 3.20 - Edit connection. Click any point of the line then click node squares and stretch.
3.5.1.4 Load
The last part of this example circuit is the load consisting of a smoothing capacitor with initial
condition and a load resistor. First, you can select the capacitor as shown in Fig. 3.21:
Fig. 3.21 - Select capacitor with initial condition.
After this selection, the capacitor appears in the middle of the circuit window in
moveable mode enclosed by a rectangle. Click on the capacitor with the left mouse
button, hold down and drag to a desired position, then click the right mouse button 3
times (or press Ctrl+R) to orient the capacitor as shown in Fig. 3.22. Finally, click on open space
to place the capacitor.
Fig. 3.22 - Placing a capacitor with initial
conditions.
Next select the load resistor in the component selection menu Branch linear + Resistor. The
resistor is drawn in moveable mode in the circuit window. Select Edit + Rotate to rotate the
resistor. Click on it with the right mouse button to rotate, then click with the left mouse button,
hold down and drag it to a desired position and place as shown in Fig. 3.23.
Fig. 3.23 - Place load resistor.
The time has come to connect the load to
Introductory Manual
ATPDraw for Windows version 3.5 47
the rest of the diode bridge. The process has been explained before. Click on the component nodes
you wish to connect with the left mouse button, sequentially. A left mouse click on open area
while in MODE: CONN.END generates a new node dot, which can be used as the starting point of
any new connections. This way creating a circuit having only perpendicular connections
(recommended for complex circuits, to improve the circuit readability) is a relatively simple task,
as shown in Fig. 3.24.
Fig. 3.24 - Your first circuit is almost ready!
After you have finished connecting the source side and the load side of the circuit, you can specify
the load data. Click with the right mouse button on the capacitor and specify the parameters shown
in Fig. 3.25:
Fig. 3.25 - Capacitor data with initial condition.
The capacitance is 1000 mF (if Copt=0 in ATP | Setting | Simulation). The positive node has an
initial voltage of 75 V and the negative -75 V. Both branch current and voltage will be calculated,
so the Current&Voltage is selected in the Output combo box. Following the branch output
request, the appearance of the object's icon will change if the Show branch output is checked
under View | Option. If this option is enabled, a small
I
U
- +
symbol appears on the top-left side of
the capacitor, indicating the branch voltage and the current output requests (see Fig. 3.29).
Next click with the right mouse button on the load resistor to get the input window and specify the
load resistance of 20 W. Branch current and voltages will be calculated so the small
I
U
- +
symbol
appears again on the top-left side of the resistor after leaving the dialog box. Once all the entries in
Introductory Manual
48 ATPDraw for Windows version 3.5
the component dialog box are completed, select the OK button to close the window and update the
object values or click Help to obtain an on-line help.
3.5.1.5 Node names and grounding
The final step of building this circuit is to give data to nodes (node names and grounding). All
nodes will automatically receive names from ATPDraw, so the user should normally give names
to nodes of special interest only. It is advised in general to perform the node naming as the last
step in building up a circuit. This is to avoid undesirable multiple node names (which is corrected
by ATPDraw automatically, but results in irritating warning messages).
To give data to a node, you simply have to click on this node once with the right mouse button.
Fig. 3.26 - Fig. 3.29 shows how to give data to four different nodes
Fig. 3.26 - Click on a node with the right mouse button and specify a name in the dialog box.
When you exit the window in Fig. 3.26 by clicking OK, the circuit is updated as shown in Fig.
3.27. All node names are forced left adjusted, and as a general rule in the ATP simulation, capital
letters should be used. ATPDraw does accept lower case characters in the node data window,
however this feature should be avoided, in particular if the node is connected with electrical
sources.
Fig. 3.27 - Click on a node with the right mouse button and specify a name in the node data
window. The name NEG will be assigned to all nodes visually connected.
Fig. 3.28 - Click on a node with the right mouse button and check the Ground box indicating that
the node is connected with the ground reference plane of the circuit.
Introductory Manual
ATPDraw for Windows version 3.5 49
The ground symbol is drawn at the selected node when you exit the window as Fig. 3.29 shows.
The nodes not given a name by the user will automatically be given a name by ATPDraw, starting
with XX for single phase and X for 3-phase nodes followed by a four-digit number. Nodes got the
name this way (i.e. from the program) are distinguished by red color from the user specified node
names, which are drown black as shown in Fig. 3.29.
Fig. 3.29 - Click on the voltage source with the right mouse button and specify the node name.
3.5.2 Storing the project file on disk
You can store the project in a disk file whenever you like during the building process. This is done
in the main menu with File | Save (or Ctrl+S). If the current project is new, a Save As dialog box
appears where you can specify the project file name and location on the disk. Two different styles
of the Save As dialog boxes are available, depending on the Open/Save dialog setting in the Tools
| Options | General menu: a Windows 9x standard dialog box and a Windows 3.1 style. The
default extension is .adp in both cases and it is automatically added to the file name you enter.
When the circuit once was saved, the name of the disk file appears in the header field of the circuit
window. Then if you hit Ctrl+S or press the Save circuit icon in the Toolbar, the circuit file is
updated immediately on the disk and the Modified flag in the status bar disappears. The File +
Save As option or the Save As Toolbar icon allows you to save the circuit currently in use under a
name other than that already allocated to this project.
3.5.3 Creating the ATP input file
The ATP-file describes the circuit according to the ATP input file syntax. You can create this file
by selecting Make File As command in the ATP main menu. The ATP-file is regenerated
whenever you just execute the run ATP command (or press F2). In the latter case the process is
hidden for the user.
However, before you create the ATP input file or run the simulation, you must not forget to
specify the miscellaneous parameters (i.e. parameters, that are printed to the Misc. Data card(s) of
the ATP input file). The default values of these parameters are given in the ATPDraw.ini file.
Changing these default values can either be done in the ATP | Settings | Simulation sub-menu for
the current project, or under the Tools | Options | View/ATP | Edit settings | Simulation for all new
ATPDraw projects created henceforth.
Fig. 3.30 shows an example of the 1
st
miscellaneous data card settings of an ATP simulation
(specifying time step, time scale of the simulation etc.). This window appears if you select the
Simulation tab of the ATP | Settings menu.
Introductory Manual
50 ATPDraw for Windows version 3.5
Select:
Time step delta T in sec.
End time of simulation Tmax in
sec.
Xopt=0: Inductance in mH.
Copt=0: Capacitance in mF.
The main characteristic of the
simulation (time domain or frequency
scan) can also be set on this page.
Press Help to get more information or
OK to close the dialog box.
The simulation settings are stored in
the project file, so you should save the
file after changing these settings.
Fig. 3.30 Simulation settings.
Values on the first integer miscellaneous data card of ATP can be changed under the ATP |
Settings | Output page. The next ATP | Settings | Switch/UM tab is the home of control flags
required by statistical switching or universal machine simulations.
Under the Format page the user can
select precision mode and the ATP-file
sorting criteria. If you select the Format
page, the window shown in Fig. 3.31
appears:
Select:
Sorting by cards: First /BRANCH,
then /SWITCH and then /SOURCE.
Printed Number Width request is
enabled. Width is the total column
width of ATP printed output LIS-
file, Space is the number of blanks
between columns.
All other check boxes are unselected
Fig. 3.31 - The ATP-file format menu.
To create an ATP-file without starting the simulation you must select the Make File As in the ATP
menu. This selection will start a procedure, which examines your circuit and gives node names to
Introductory Manual
ATPDraw for Windows version 3.5 51
circuit nodes. Then a standard Windows Save As file window appears, where you can specify the
name and path of the ATP-file. The same name as the project file with extension .atp is
recommended. You can edit this file or just display it by selecting the ATP | Edit ATP-file menu.
The ATP-file (Exa_1.atp) you have just created will look like as follows:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW December, Saturday 1, 2001
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2001
C --------------------------------------------------------
PRINTED NUMBER WIDTH, 10, 2,
C Example 1
C Your first circuit
C Rectifier bridge
C dT >< Tmax >< Xopt >< Copt >
5.E-5 .05
500 1 1 1 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
XX0031 33. 1. 0
NEG 33. 1. 0
XX0031POS .01 1
POS NEG 1.E3 3
NEG POS 20. 3
VS XX0021 1. 0
VS XX0021 300. 0
NEG VA 33. 1. 0
VA XX0031 33. 1. 0
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
11VA XX0031 0
11 XX0031 0
11NEG VA 0
11NEG 0
XX0021VA MEASURING 1
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14VS 0 167.7 60. -90. -1. 1.
/INITIAL
2POS 75.
2NEG -75.
3POS NEG 150.
/OUTPUT
VS
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
3.5.4 Running the simulation
Starting the ATP simulation is supported in ATPDraw in a user friendly way. The user just has to
press F2 function key to create an ATP input file with the current project file as input and run the
simulation. The default command that is executed when the user selects run ATP under the ATP
menu or when the F2 is pressed can be specified under the Tools | Options /Preferences tab as it
has been described in section 2.6 of the Installation Manual.
Introductory Manual
52 ATPDraw for Windows version 3.5
3.6 Three phase circuits (Exa_2.adp)
Both single-phase circuits and three-phase circuits are available in ATPDraw. For 3-phase objects,
the number of phases is indicated in the selection menu. The icon border of the 3-phase objects is
generally thick or gray shaded and the icon consists of thick lines from the nodes into the object
symbol.
All three-phase nodes have only 5 characters available in the Node data windows. ATPDraw adds
the extension A, B and C at the end of the node name. By default, the phase sequence is ABC; the
first data card uses A, the second B and the last C. The only way to change the phase sequence is
to use the available transposition objects (Transp1 - Transp4) selectable under Probes & 3-
phase in the component selection menu.
The current phase sequence is displayed in the bottom of the node input window after an ATP |
Make Names or Make File As selection has been made. The following example illustrates the
usage of three-phase objects:
Fig. 3.32/a - Illustrative three-phase circuit.
Fig. 3.32/b - Equivalent ATPDraw circuit (Exa_2.adp).
The circuit shown in Fig. 3.32 was built up in the same way as your first circuit. You can note that
connections between the three phase nodes appear to be thick. The circuit contains 3 special
objects, the already mentioned transposition object (in this case from ABC to BCA), a splitter
object, which splits three phase nodes into three single-phase nodes and an ABC reference object.
Names 1 - 8 have been given to nodes in the circuit. By selecting Make Names under ATP in the
main menu, ATPDraw examines the circuit and creates unique node names.
If you click with the right mouse button on nodes after selecting ATP | Make Names you are able
to see the phase sequence in the bottom of the node input window as shown in Fig. 3.33/a and Fig.
3.34/b.
The single phase nodes do not have a phase sequence, but the single phase side of a splitter object
has one, as shown in Fig. 3.34/b.
Introductory Manual
ATPDraw for Windows version 3.5 53
Fig. 3.33/a - Click right button on node 1. Fig. 3.33/b - Click right button on node 4.
The node names in Fig. 3.33/a are 1A, 1B and 1C, all left adjusted. The node names in Fig. 3.33/b
are 1B, 1C and 1A, all left adjusted. ATPDraw gives the phase sequence ABC to the sub-network
left of the first transposition object, that can be overridden by connecting an ABC reference object
to any 3-phase nodes of the circuit.
Fig. 3.34/a - Click right button on node 7. Fig. 3.34/b - Click right on single-phase node 8.
Fig. 3.35 - Click the right mouse button on single-phase right node of the resistor.
A node name is not assigned to the right node of the resistor (Fig. 3.35). ATPDraw thus gives the
node a name starting with XX followed by a unique number. This node is a single-phase node with
no phase sequence. 3-phase nodes with no user specified names are given a name starting with X,
followed by a four digit number and ending with the phase sequence letters A, B and C.
Some special restrictions apply to the splitter objects (found under Probes & 3-phase in the
component selection menu):
Introductory Manual
54 ATPDraw for Windows version 3.5
Connecting splitter objects together on the 3-phase side or with connections on the 1-phase
side is permitted (earlier it was illegal), but transposition/disconnection is not allowed.
If the name NODEA is given to what you know is phase A on the single phase side, ATPDraw
does not accept this and adds its own A at the end, creating the node name NODEAA. The
general rule is that ATPDraw takes care of the phase sequence alone!
Best solution is to specify a node name on the 3-phase side only.
The ATP data file created by ATPDraw from the circuit in Fig. 3.32/b is shown below:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Tuesday 30, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
C dT >< Tmax >< Xopt >< Copt >
1.E-6 .001
500 1 1 1 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
1 1A 2A 10. .0001 1.
2 1B 2B .0001 1. 10. .0001 1.
3 1C 2C .0001 1. .0001 1. 10. .0001 1.
3B 4B 1. .001 0
3C 4C 1. .001 0
3A 4A 1. .001 0
514B 5B 2. 1.5
524C 5C 1. 1.
534A 5A
513B 7B 10. 1.
523C 7C 2. 10. 1.
533A 7A 2. 2. 10. 1.
515B 6B 10. 1.
525C 6C 2. 10. 10.
535A 6A 2. 2. 10. 1.
547C 8C 2. 2. 2.
10. 1.
557A 8A 2. 2. 2.
2. 10. 1.
567B 8B 2. 2. 2.
2. 2. 10. 1.
8C XX0021 1.E3 0
8A XX0023 1. 0
8B XX0025 10. 0
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
2A 3A .0001 .001 0
2B 3B -1. .001 0
2C 3C -1. .001 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
141A 0 1.5E5 60. -1. 1.
141B 0 1.5E5 60. -120. -1. 1.
141C 0 1.5E5 60. 120. -1. 1.
/INITIAL
/OUTPUT
3A 3B 3C
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
55
4. Reference Manual . . .
. . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Reference Manual
ATPDraw for Windows version 3.5 57
This part of the manual outlines all menu items and program options, and gives an overview about
the supported ATP objects, TACS, LCC components and MODELS features.
ATPDraw has a standard Windows user interface. The Main window of the program is shown in
Fig. 4.1. The Main menu, the Circuit window and the Component selection menu are the most
important items of that window. Elements of the Main menu and supported ATP components in
the Component selection menu will be referenced in this part of the manual.
4.1 Main window
Fig. 4.1 - Components of ATPDraw's main window.
If you are unfamiliar with the use of ATPDraw, read the Introductory Manual to learn how to
create a circuit or the Advanced Manual to learn how to create a new object in ATPDraw. The
Introductory Manual starts with the explanation of operating windows and the mouse in
ATPDraw, and shows how to build up a circuit and how to create an ATP-file to be used as input
for a subsequent transient simulation.
Main menu Tool bar icons Component
tool bar
Map
Window
Current
action mode
Component
selection menu
Status bar with
menu option hints
Circuit window
Reference Manual
58 ATPDraw for Windows version 3.5
4.2 Main menu
4.2.1 File
This field contains actions for input/output of ATPDraw projects.
Selecting the File item in the main menu will result in a popup menu
shown in Fig. 4.2.
Fig. 4.2 - File menu.
4.2.1.1 New
Selecting this menu item will open a new empty Circuit window. ATPDraw supports to work on
several circuits simultaneously and copy information between the circuits. The number of
simultaneous open windows is limited only by the available MS-Windows resources. The circuit
window is much larger than the actual screen, as it is indicated by the scroll bars of each circuit
windows.
4.2.1.2 Open
This menu performs a Windows standard Open dialog box shown in Fig. 4.3. In this window the
user can select a project file and load it into the ATPDraw. Short key: Ctrl+O.
Fig. 4.3 - Open file
window (Win9x style).
Reference Manual
ATPDraw for Windows version 3.5 59
ATPDraw can read both circuit (.cir) files created by an earlier version of the program and project
files (.adp). When opening a project file ATPDraw first unzips the files (e.g. .lib, .mod, .alc, .bct
or .sup files) belong to the project and store them in the specified folders. If a folder name
specified in the project file is unknown, the default folder will be used. If a file already exists on
the target location with a different creation date/time, ATPDraw lets the user to choose which file
to keep.
This Open/Save dialog box is used for several different selections in the main menu. An
alternative MS-Windows 3.1 style is also supported as shown in Fig. 4.4. There is a check box in
the Tools | Options | General tab to switch between the two supported alternatives.
Fig. 4.4 - Open file window
(Win 3.1 style).
The existing project files in the \Project subfolder of ATPDraw are shown below the File
name: field. A specific file can be selected either by typing the name directly, or by a left mouse
click in the file list. Clicking OK will perform the selection made and the file is loaded into a new
circuit window. Clicking on Cancel will simply close the window.
4.2.1.3 Reload
The name and location of the recently used project files are listed right to this menu item. The user
can select and load one of them into the circuit window by a simple mouse click.
4.2.1.4 Save
Activating this menu item will save the project in the active circuit window into a disk file. If the
name Noname.adp is shown in the circuit window a Save As dialog box will be performed,
where the user can specify a new name for the current project file name. Short key: Ctrl+S.
4.2.1.5 Save As
The project in the active circuit window is saved to disk under a new name. The name of the file
can be specified in the Save As dialog, which is similar to the Open Project dialog in Fig. 4.3 or in
Fig. 4.4. This command allows the user to save the project under a name other than that is already
used. ATPDraw can read circuit files (.cir) created by earlier program versions, but the Save As
command supports only the new file format. The default extension of the project files on disk is
Reference Manual
60 ATPDraw for Windows version 3.5
(.adp). The project file contains the circuit description along with all user specified support (.sup),
model (.mod), line/cable (.alc) or transformer (.bct) data and library (.lib) files in Zip-compressed
format.
4.2.1.6 Save All
Saves all modified projects to disk under their own project file names. If one or more open
projects still have not got a name (Noname.adp), it will be requested in a Save As dialog boxes
successively.
4.2.1.7 Close
Close the active circuit window. If any changes to the circuit have not been saved yet, the user will
be warned as shown in Fig. 4.5 to confirm before the circuit is closed. If the project has been
modified, the user is given a chance to save it first.
4.2.1.8 Close All
Close all circuit windows. If a project has been modified since the last save operation, a
confirmation dialog will be prompted giving a chance for the user to save it first.
Fig. 4.5 - Confirmation prevents the loss of
unsaved project data.
4.2.1.9 Import
This command inserts a circuit from disk file into the active circuit window contrary to the Open
command, which loads the circuit into a new circuit window. Selecting this menu will result in an
Import Project dialog box where the user can select the file to load. The imported circuit appears
in the circuit window as a group in marked moveable mode. Existing node names will be kept or
rejected upon the selection of the user.
4.2.1.10 Export
Save the selected objects of the active circuit to a disk file. Same as Save As, but only the selected
objects (marked by a rectangular or polygon area) of the circuit is written to the disk file.
4.2.1.11 Reload Icons
Reads and displays component icons from their respective support files. This function is useful
when the user has redesigned one or more support file icons and wants the changes to be reflected
in the circuit window.
Reference Manual
ATPDraw for Windows version 3.5 61
4.2.1.12 Save Metafile
Write the selected objects of the active circuit to a disk file in Windows metafile (.wmf) format. If
no objects are selected, the entire circuit window content is written to disk. This way even
graphics of large circuits can be exported to other applications without loss of resolution seen on
the screen when the Zoom option is used to fit the circuit to the screen size. Metafiles created by
this command can be imported as picture into other applications (like MS-Word or WordPerfect)
having filter available to this format.
Note! Direct printing is not supported in ATPDraw v3.0 due to a scaling problem that made this
feature useless anyway.
4.2.1.13 Exit
This command closes all open circuit windows of ATPDraw. User will be asked to save any
modified circuits before the application is terminated.
4.2.2 Edit
This menu contains the various edit facilities of circuit objects in ATPDraw. The Edit popup
menu is shown in Fig. 4.6.
An object or group of objects must be selected before any edit
operation can be performed on them. If the user clicks on an
object with the left mouse button in the circuit window the icon of
the object will be rounded by a rectangular frame indicating that it
is selected.
Fig. 4.6 - Edit menu.
4.2.2.1 Undo/Redo
The Undo command cancels the last edit operation. The Redo cancels the last undo command.
Short key for Undo/Redo: Alt+Backspace and Shift+Alt+Backspace. The number of undo/redo
operations depends on the Undo/redo buffers: setting on the Preferences tab of the Tools | Options
menu. Default value is 10. Almost all object manipulation functions (object create, delete, move,
rotate, etc.) can be undone (or redone). Changes made to the circuit data in the component dialog
Reference Manual
62 ATPDraw for Windows version 3.5
box are also supported by the Undo/redo functions. These functions also update the circuit's
Modified state in the status bar to indicate that the circuit has been modified. During an undo
operation, the modified state is reset its previous value.
4.2.2.2 Cut
Copies the selected objects to the Windows clipboard and deletes them from the circuit window.
The objects can later be pasted into the same or other circuit windows, or even other instances of
ATPDraw. Short key: Ctrl+X.
4.2.2.3 Copy
The selected objects are copied to the clipboard. Short key: Ctrl+C. A single marked object or a
group of objects can be copied to the clipboard. This command unselects the selected objects.
4.2.2.4 Paste
The contents of the clipboard are pasted into the current circuit when this menu item is selected.
Short key: Ctrl+V. The pasted object or objects appear in the current window in marked moveable
mode.
4.2.2.5 Duplicate
Copies the selected object or a group of objects to the clipboard and then duplicates them in the
current circuit window. Duplicated objects appear in the current window in marked moveable
mode. Short key: Ctrl+D.
4.2.2.6 Clear
Selected objects are removed the from the circuit window. Short key: Del.
4.2.2.7 Copy Graphics
The selected objects are copied to the clipboard in Windows Metafile format. This way graphics
of selected objects can be exported to other Windows applications. Short key: Ctrl +W.
4.2.2.8 Select
This menu has four sub-menus:
All: Select all objects in the current circuit window. Short key: Ctrl +A.
None: To cancels the object selection. Short key: Ctrl +N.
Polygon: Enables object selection by a polygon shaped region. Short key: Ctrl +P (or
double-click with the left button in an empty region of the circuit window).
Type/Group: Enables selection by objects' support file name or group number (see
below). Short key: Ctrl +T.
A selected object or group of objects can be subject of the most editing operations: Move (click
left button, hold down and drag), Rotate/Copy/Duplicate/Erase or Export (in the File menu). To
Reference Manual
ATPDraw for Windows version 3.5 63
unselect a group, select None, or just click with the left mouse button in an empty space of the
circuit window.
In Polygon mode, the mouse cursor icon changes its style to a pointing hand and moves to the
middle of the circuit window. The current action mode also changes to MODE:GROUP in the
status bar. To draw a polygon around a group of objects move the cursor to the starting location
and click the left mouse button. Then release the button and a rubber band line will be drawn
between the starting point and the current mouse cursor location. And so forth: left click to create
corners, right to complete the polygon. All objects with midpoint inside or connections with both
endpoints inside the polygon will be included in the selection.
In the Type/Group selection mode the group of components can be selected by their type and/or
group number. The type here is the name of the support file and the group number is the identifier
specified in the component dialog box.
The available component types and support names are listed in two
combo boxes as shown in Fig. 4.7. When you click on OK the
components with the selected group number and/or support file name
become selected. Then all kinds of edit operation can be performed on
the group (copy/paste, copy graphics, rotate, edit, grouping etc.).
Fig. 4.7 - Selecting objects by name or group no.
4.2.2.9 Move Label
This menu is used to select and move a component or node text label. Short key: Ctrl+L.
All circuit objects can have a label. These labels are displayed on the screen in blue (component
label) or in red color (node name). Selecting the Move Label menu item, the mouse cursor style
will change to a pointing hand and move to the middle of the circuit window. The action mode
indicator in the status bar will also change to MODE: MOVE LABEL. In this operating mode any
label can be dragged to a new position by clicking the label with the left mouse button, holding the
button down and move. This operation ends and the mouse is unlocked when you finish moving a
label and the mouse buttons is released. In most cases, when the component icons do not overlap
the labels, it can be moved by a simple left click then holding the left mouse button down and
move. Therefore, the Move Label command is most frequently used when labels are located close
to or behind the component icons and cannot be selected otherwise.
4.2.2.10 Rotate
This command rotates the selected object(s) 90 degrees counter-clockwise. This operation can also
be performed by clicking the right mouse button inside the selected group. Short key: Ctrl + R.
Reference Manual
64 ATPDraw for Windows version 3.5
4.2.2.11 Rubber Bands
If this option is checked, connections with one endpoint inside a selected region and one outside
are treated as a rubber band between the selected group and the rest of the circuit. Short key: Ctrl
+ B. This command does not work for short cut single component selections: e.g. left click on
several components while the Shift key is pressed, because this way no connections are selected.
4.2.2.12 Compress
This command will replace a group of selected objects with a single icon having user selectable
external data and nodes. ATPDraw supports real grouping or single icon replacement of sub-
groups in unlimited numbers of layers. The process requires a group selection first. The Compress
dialog box (see Fig. 4.8) appears where the user designs the new group object.
In the Compress dialog box the user can specify the external data and nodes of the compressed
circuit. The selected data and nodes appear as input to the group object that replaces the selected
circuit and their values are automatically transferred. A nonlinear characteristic common for up to
3 components can also be selected as external data.
Under Objects: all the components in the group are listed with their name (support file) followed
by their label. When the user clicks on one of the component's name, its data and nodes appear
under Available: starting with data/node name and followed by their names and values. Here the
user can select a parameter and click on the >> button to transfer it to the Added to group: list. All
data and nodes listed in the Added to group: will be an external attribute of the new group object.
The position of the external nodes on the icon border (1-12) can be specified in the lower right
corner of the dialog box. You can change the Added to group: names by double clicking on them.
Data with the same name are treated as a single data in the component dialog box (Fig. 4.8/b).
Selected data and nodes can also be removed from the Added to group: by clicking on the <<
button.
As all other components, the group object is limited to 36 data and 12 nodes. When later you open
the component dialog box of the group-object, the selected data values and node parameters will
appear as input possibilities. The values will automatically be transferred to the sub-group as
shown in Fig. 4.8/b.
4.2.2.13 Extract
This is the reverse operation of Compress. The group is extracted on the current circuit layer. To
perform the operation, a compressed group (and only one!) must be selected first.
4.2.2.14 Edit Group
This command shows the group content. Short key: Ctrl+G. The group is extracted in a separate
window. To perform the operation a compressed group (and only one!) must be selected first. It is
possible to edit the group in a normal way, except deletion of the reference components. I.e.
components having been referenced in one of the Added to group: lists cannot be deleted. If the
user tries a "Marked objects are referenced by compressed group..." warning message appears.
Reference Manual
ATPDraw for Windows version 3.5 65
Fig. 4.8/a - The Compress dialog box.
Fig. 4.8/b - Component dialog box for a sub-group object.
4.2.2.15 Edit Circuit
Displays the circuit where the current group belongs. Short key: Ctrl + H. Actually the grouping
structure can be taken as a multi-layer circuit, where the Edit Group brings the user one step down
in details, while Edit Circuit brings one step back. The group object (single icon replacement of
objects) acts as the connection between the layers and transfers data between them.
4.2.2.16 Comment...
Opens a comment dialog box (see Fig. 4.9), where three text lines can be entered. These
comments serve as a commentary section for the circuit in the header section of the .atp file.
Selecting the Comment Line option checked in the View menu will display these comments at the
Reference Manual
66 ATPDraw for Windows version 3.5
bottom of the circuit window, as well. This menu also enables the user to change the circuit
comment if it already exists.
Fig. 4.9 - Circuit comments dialog box.
4.2.3 View
This menu provides options for displaying and controlling the visibility of
user interface and circuit window objects. The menu items are shown in Fig.
4.10.
Fig. 4.10 - View menu.
4.2.3.1 Toolbar
Shows or hides the toolbar at the top of the main window. The toolbar contains speed buttons for
the most frequently used menu options. Available toolbar icon are as follows:
Opens an empty circuit window
Loads a circuit file into a new window
Saves the objects in the active circuit window to disk
Saves the objects in the active circuit window to a specified disk file
Inserts a circuit from file into the active circuit window
Saves the selected objects of the active circuit to a disk file
Cancels the last edit operation
Cancels the last undo command
Copies the selected objects to the Clipboard and deletes them from the circuit window.
The objects can later be pasted into the same or other circuit windows.
Copies the selected objects to the Clipboard
Inserts the objects in the Clipboard into the circuit window
Copies the selected objects to the Clipboard and then inserts them into the circuit.
Enables the user to select and move a component or node text label. The mouse cursor
type will change to a pointing hand.
Reference Manual
ATPDraw for Windows version 3.5 67
Redraws all objects in the active circuit window
Selects all objects in the active circuit window
Enables the user to select a group of objects by specifying a polygon shaped region in the
active circuit window. The mouse cursor style will turn to a pointing hand to indicate this
mode of operation. To close the region and unlock the mouse, press the right mouse button.
Enlarges the objects by increasing the current zoom factor by 20 percent
Diminishes the objects by reducing the current zoom factor by 20 percent
Rotates the selected objects 90 degrees counter-clockwise. This operation can also be
performed by clicking the right mouse button inside the selected region
Flips the selected objects by rotating 180 degrees
To the right of the speed buttons the nine most recently used component icons are displayed.
Selecting one of these shortcut icons inserts a new component into the active circuit window. The
leftmost icon represents always the last inserted component.
4.2.3.2 Status Bar
Status bar on/off at the bottom of the main window The status bar displays status information
about the active circuit window. The mode field on the left hand side shows which mode of
operation is active at present. Possible modes are:
EDIT Normal mode. Indicates no special type of operation.
CONN.END Indicates the end of a connection. The program is waiting for a left mouse
button click to set the end-point of a new connection. To cancel drawing a
connection, click the right mouse button or press the Esc key.
MOVE LABEL Indicates a text label move. Clicking the left mouse button on a text label,
then holding down and dragging enables you to move the label to a position
of your choice. To cancel moving a label, click the right mouse button or
press the Esc key.
GROUP Indicates region selection. Double clicking the left mouse button in an
empty space of the active circuit window enables you to draw a polygon
shaped region. To finish the selection click the right mouse button. Any
object within the selected region is then marked for selection. To cancel
region selection, press the Esc key.
INFO.START Indicates the start of relation drawing when the TACS | Draw relation was
selected in the component selection menu. Clicking the left mouse button
on a component node or on the end-point of another relation will initiate the
drawing of a new relation. Relations are used to visualize information flow
into Fortran statements and are drawn as blue connections, but do not
influence the connectivity of components.
INFO.END Indicates the end of a relation. The program is waiting for a left mouse
click to set the end-point of a new relation. To cancel drawing a relation,
click the right mouse button or press the Esc key.
Reference Manual
68 ATPDraw for Windows version 3.5
The field to the right of the mode field displays the modified status of the active circuit. As soon
as you alter the circuit (moving a label, deleting a connection, inserting a new component, etc.),
the text Modified will show up to indicate that the circuit needs saving. The field will be empty
when you save the circuit or undo all modifications. Note that the number of available undo
buffers is limited (default value is 10, but can be increased on the Preferences tab of the Tools |
Options menu). In the default case, if more than 10 modifications are done, the field will indicate
a modified status until you save the circuit.
The rightmost field of the status bar displays the menu option hints.
4.2.3.3 Comment Line
Shows or hides the comment line at the bottom of the active circuit window.
4.2.3.4 Zoom In
Enlarges the objects in the active circuit window by increasing the current zoom factor by 20
percent. Short key: + (plus sign on the numeric keypad or "=/+" alphanumeric key).
4.2.3.5 Zoom Out
Reduces the icon size in the active circuit window by 20 percent. Short key: - (minus sign on the
numeric keypad or the "-/_" alphanumeric key).
4.2.3.6 Zoom
Selecting this field brings up the Zoom dialog box shown in Fig. 4.11. Short key: Z. In the Zoom
dialog the zoom factor of the active circuit window can be specified. The actual zoom factor is
given in the input field at left in percent. The normal view has a zoom factor of 100 percent. To
zoom in increase the zoom factor, to zoom out and view a larger portion of the circuit, decrease
the factor. Upper and lower limits are 400 and 25 percent, respectively.
To accept the new zoom factor and return from the Zoom dialog,
select the OK button. To set a new zoom factor and view the
result without closing the dialog box, select the Apply button.
Fig. 4.11 - The Zoom dialog box.
4.2.3.7 Refresh
This command redraws all objects in the active circuit window. Short key: R. This command can
also be activated by clicking the Toolbar icon:
Reference Manual
ATPDraw for Windows version 3.5 69
4.2.3.8 Set Circuit Font
Enables you to select a font type and size for the node names and labels on the screen (and also for
the metafile export). The default font is MS Sans Serif, regular, 8 pt size.
4.2.3.9 Options
Selecting this menu item will bring up the View Options dialog box. The View Options dialog can
be used to control the visibility of the objects in the active circuit window.
Fig. 4.12 - View Options dialog box.
By default, all objects except node names are visible. The meaning of options assuming the option
is selected () are listed below:
Components All standard and user specified components are displayed.
Tacs All TACS components are displayed.
Models All MODELS components are displayed.
Connections All connections (short circuits between nodes) are displayed.
Relations All relations (to visualize connections between Fortran statements and other
objects) are displayed.
Labels Component labels are displayed on the screen.
Node dots Node and connection end-points are displayed as filled circles.
Node names Node names are visible on the screen (overrides the Display attribute of the
Node data window). This option is useful after a Make Names selection in
the ATP menu.
Drag icon The complete icon is seen when a selected object or group of object is
moved on the circuit window (in the unchecked state, only an inverted
rectangular or polygon outline is drawn).
No Data warning Components and node dots are drawn with a red color until the component
or node is opened and given meaningful data. No such checking is done
when this option is unselected.
Show branch output Small U/I symbols indicate the selected branch output requests. Branch
output requests can be specified in most of the component dialog boxes.
To accept the current view options and return from the dialog, select the OK button. To set and
view new options without returning, select the Apply button. If you want the current settings be
applied to all current and future circuit windows, select the Apply All button before you exit the
dialog box.
Reference Manual
70 ATPDraw for Windows version 3.5
4.2.4 ATP
The ATP menu provides options to create, display and modify the ATP input files and to set
circuit specific ATP options (e.g. DT, Tmax) before running the case by the Run ATP command or
the F2 function key. Other components of the ATP-EMTP package
(e.g. pre- and post-processors, supporting programs and utilities)
can also be launched from this menu. Besides the default
commands, the user can add additional commands (e.g. Run PlotXY
/ Run Analyzer / Run PCPlot / Run TPPlot, etc.) to the existing
program items, which are listed immediately below the Edit
commands...as shown in Fig. 4.13.
Fig. 4.13 - The ATP menu.
4.2.4.1 Settings
In the ATP Settings... dialog box several options for the active circuit window can be specified.
These settings are used when ATPDraw generates the ATP input file. Options are sorted in six
tabs, such as the Simulation and Output for the miscellaneous data card settings, Switch/UM for
statistical and Universal Machine studies, Format for specification of data-card sorting options
and miscellaneous request, Record for MODELS output specification and the new Variables.
Simulation settings
Simulation type: Select between the
simulation methods supported by
ATP:
o Time domain
o Frequency Scan
o Harmonic Frequency Scan (HFS)
Time domain
delta T: Time step of simulation in
seconds.
Tmax: End time of the simulation in
seconds.
Xopt: Inductances in [mH] if zero;
otherwise, inductances in [Ohm]
with Xopt as frequency
Copt: Capacitances in [mF] if zero;
otherwise, capacitances in [Ohm]
with Copt as frequency.
Freq: System frequency in Hz
Fig. 4.14 - Simulation settings.
Power Frequency: when checked the SYSTEM FREQUENCY request card is written in
the ATP-file.
Reference Manual
ATPDraw for Windows version 3.5 71
Frequency scan
If Frequency scan is selected the FREQUENCY SCAN option of ATP is enabled.
min: Starting frequency for the frequency scan
max: Ending frequency for the frequency scan
df: Frequency increment. Leave 0 for logarithmic frequency scale
NPD: Number of frequency points per decade in logarithmic scan
Harmonic Frequency Scan (HFS)
Selecting HFS will run the ATP data case so many times as specified in the
Harmonic source component dialog box (see chapter 4.9.12). The frequency of
the harmonic source will for each ATP run be incremented. The basic frequency
specification is mandatory for HFS simulations, which can be set as Freq.
parameter on Fig. 4.14.
If Frequency scan or HFS is selected the user must specify which component of
the solution to print out:
Magnitude only: Default request
Magnitude & Angle: Results are printed in POLAR
Magnitude & Angle & Real/Imag: Both POLAR and RECTANGULAR
Real/Imag: RECTANGULAR output request. Other combinations are illegal and are
prevented by button logic.
Output settings
Output control
Print freq.: Frequency of LUNIT6
output within the time-step loop.
For example, a value of 500 means
that every 500
th
simulation time
step will be printed to the LIS-
file. This option controls ATP's
1
st
misc. data parameter IOUT
Plot freq.: Saving frequency of
the simulation data to the .pl4
output file. A value of 5 means
for example, that every fifth
time step will be written to the
PL4-file. This option controls
ATP's 1
st
misc. data parameter
IPLOT
Fig. 4.15 - Output request tab.
Plotted output: If checked ATPDraw sets the 1
st
misc. data parameter ICAT=1 in
the ATP input file which results in a .pl4 output file.
MemSave: Controls the dumping of EMTP memory to disk at the end of simulation
if START AGAIN request is specified. If checked indicates memory saving.
Auto-detect simulation errors: If this option is selected, ATPDraw will
analyze the output LIS-file of ATP following the completion of the simulation.
If the specified trigger string is found, the corresponding section of the
file is displayed in a Notepad window. This feature helps the user to
recognize the simulation errors/warnings generated by ATP during the time step
loop or input data interpretation. The string or strings, which makes this
function work, are user selectable and activating at least "Error" and "Kill
code" are highly recommended.
Reference Manual
72 ATPDraw for Windows version 3.5
Printout
Network connectivity: If checked connectivity table (description of the
topology of the circuit) is written to the LUNIT6 output file. This option
controls ATP's 1
st
misc. data parameter IDOUBLE. If unchecked, no such table is
written.
Steady-state phasors: If checked complete steady state solution (branch flows,
switch flows and source injection) is written to the LUNIT6 output file This
option sets ATP's 1
st
misc. data parameter KSSOUT=1. If unchecked, no such
output is produced by ATP.
Extremal values: If checked, extrema of each output variables will be printed
at the end of the LIS-file. This option controls ATP's 1
st
misc. data parameter
MAXOUT. If unchecked, no such output is produced by ATP.
Extra printout control: Additional control for the frequency of LUNIT6 output
within the time-step loop. If checked, the 1
st
misc. data parameter IPUN is set
to -1 and a 2
nd
misc. data card will appear in the ATP input file. Parameters
KCHG and MULT control the breakpoints and the new Print freq. value. If
unchecked, IPUN is set to 0 and LUNIT6 printout frequency will be constant
throughout the simulation.
Switch/UM settings
Switch study
Statistic study: Study with statistic
switches
Systematic study: Study with systema-
tic switches
Num: Number of simulations. This value
influences ATP's 1
st
misc. data
parameter NENERG. ATPDraw sets the
correct sign of NENERG: i.e. >0 for
statistic or <0 for systematic switch
studies.
Switch controls
ISW: If 1, printout of all switch
closing/opening time appear in the
output LIS-file. No such printout if
the parameter is set to 0.
Fig. 4.16 - Switch/UM settings.
ITEST:Extra random delay using DEGMIN, DEGMAX and STATFR in STARTUP.
Possible values are:
0: Extra random delay for all switches.
1: No random delay.
2: Extra random time delay added to all closing switches.
3: Extra random time delay added to all opening switches.
IDIST: Select probability distribution function of subsequent switching
operations. Zero means Gaussian distribution and 1 means uniform distribution.
IMAX: If 1, printout of extrema is written to the ATP output LIS-file for
every energization. If 0 (zero), no such printout.
IDICE: Controls use of the random generator. A value of 0 implies computer-
dependent random generator and a value of 1 means standard random generator.
KSTOUT: If 0, extra printed (LUNIT6) output for each energization. Output of
the time-step loop and variable extrema (if Extremal values is selected on the
Output tab) will be printed. If -1, no such output.
Reference Manual
ATPDraw for Windows version 3.5 73
NSEED: Repeatable Monte-Carlo simulations. Possible values are:
0: Every simulation on the same data case will be different.
1: Same result each time the data case is run on the same computer.
Universal machines
Here the user specifies the global data for the Universal electrical machine
models in ATP. The selections here apply to all universal machines in the
circuit.
Initialization: Manual: Terminal quantities of all machines must be specified.
Automatic: Initial conditions will be calculated by ATP. See section 9D1.5 for
more details in the ATP Rule Book.
Units: Input variables are specified in SI units or Per unit (p.u.)quantities.
Interface:
Compensation: The machine does appear to be a nonlinear element to the
external network. Certain rules regarding connecting machines together must be
followed. Inclusion of stub lines is often required.
Prediction: The machine does not appear to be a nonlinear element to the
external network. This option is not available for single phase machines.
Format settings
The Format settings page contains four buttons for setting of ATP input file data format, a button
for controlling the auto path generation and several other buttons for miscellaneous request cards.
The Additional button supports the user to insert any request card or text strings in the ATP-file on
precise location.
Sorting
Sorting by cards: The sequence of ATP
input data follows the default sequence
of / data sorting cards (i.e. BRANCH
cards are written first, followed by
SWITCH cards and the SOURCE cards).
Sorting by group number: The group
number that can be specified in the
component dialog box for each object
determines the sequence of cards. The
lowest group number comes first.
Sorting by X-pos: The leftmost object
in the circuit window is written first.
Any combination of the three different
sorting mechanisms can be specified.
Force high resolution: Use $Vintage, 1
(if possible), for high precision data
input.
Fig. 4.17 - ATP-file format settings.
Miscellaneous request
Insert $Prefix and $Suffix cards: If this option is checked, ATP run time
calls for library or data file via $Include commands will suppose that these
external files are located in the /USP folder of ATPDraw and have the
extension .lib. Having this control enabled, only the pure file name need to
be specified in the $Include field of a component dialog box, because the
default extension .lib and the complete path will be appended by ATPDraw using
the $Prefix, $Suffix features of ATP-EMTP.
Each library file specification is verified to meet the above requirements. If
the path of a library file specifies a different folder or the extension is
Reference Manual
74 ATPDraw for Windows version 3.5
not .LIB, an error dialog appears during the ATP-file generation process. The
user has 3 options:
a) correct the erroneous specification by stripping off path and extension,
b) continue the operation using an unresolvable ATP $Include reference,
c) cancel the entire input file generating process.
If you prefer storing library files outside of the /USP folder or file
extensions other than .lib are often used, it is wise not to select this
option and specify a complete path in the $Include field.
Insert $PL4 Comments: If checked, ATPDraw writes the circuit comments in a
$BEGIN PL4 COMMENTS...$END PL4 COMMENTS block. This may result in an error for
some (older) ATP versions.
Insert Exact Phasor Equivalent card: If checked, ATPDraw writes an EXACT
PHASOR EQUIVALENT request in the ATP-file. This is recommended for Frequency
Scan simulations including constant and distributed parameter overhead lines.
Insert TACS HYBRID card: Checking this button forces TACS HYBRID .. BLANK TACS
to be written to the ATP-file. Useful when TACS objects are only present
inside a User Specified Object.
Printed Number width: Enables the PRINTED NUMBER WIDTH request card, which
controls the printout of the LUNIT6 device (output LIS-file). Width: is the
total column width of printed output including blanks separating the columns.
Space: is the number of blanks between columns of printed output.
Additional
The Additional button enables the user to insert text strings on precise locations in the ATP-file.
Text strings to be written can be specified in an editor-like dialog box as shown in Fig. 4.18.
First, the user must specify a
type (0-8; see the list at right),
then the text string to be written
in the ATP-file. The header of
columns 1-80 helps to locate the
string properly, according to the
ATP specification. The text
string will be written after a /
data sorting card at the end of
other cards belonging to that
group (/REQUEST, /TACS,
etc.).
Fig. 4.18 - Specification of additional miscellaneous request cards.
Record
ATPDraw supports the RECORD feature of ATP MODELS via the Record dialog box which is
shown in Fig. 4.19. All MODELS objects in the active circuit window are listed with their USE
AS name in the list box under Model. When selecting a model in this field, variables (declared
under VAR section of the .mod file) are listed under Variable. Each variable has a default alias
name that appears in the Alias field, but it can be modified according to the user need.
Reference Manual
ATPDraw for Windows version 3.5 75
To record a variable, one has to click on the Add
button. The alias name can be changed later by
selecting an item in the Record list box and type
in a new name.
This record list is stored in the circuit file, but it
does not follow the circuit when the circuit is
copied to the clipboard or the export group option
is used. The record requests can be removed by
selecting the item and click on the Remove.
Fig. 4.19 - Record of MODELS variables.
Variables
The Variables dialog box is new in ATPDraw 3.x to support the $PARAMETER feature of ATP-
EMTP. The user is allowed to specify a 6-character text string instead of a numerical value in the
component dialog boxes as shown in Fig. 4.20.
Fig. 4.20 - Using text
string instead of variables
in the RLC component
dialog box.
A numerical value then can be assigned later to these text strings under Variables. The text strings
(variables) specified by the user appear to the left and the user now has to assign data values for
variables. This is done in free format in the column to the right as shown by Fig. 4.22. Users do
not have to think about the number of characters in the final ATP-file since ATPDraw
automatically adds underscore characters to obtain the maximum resolution. A variable R used
both for high and low precision resistances will thus be declared twice with 5 and 15 underscore
characters added. This process is hidden, but the result is seen in the final ATP-file under the
$Parameter declaration.
IMPORTANT! Always use a period '.' after a number in the value field.
Reference Manual
76 ATPDraw for Windows version 3.5
Changing the names in the left side
column will affect the text strings
(variables) specified in the component
dialog boxes. An example is shown in
Fig. 4.22. If the variable R is changed to
RES, the variable R used in some
component dialog box will no longer be
assigned. Therefore, the user is requested
about what action to take.
a) reset the variable R to zero,
b) set default value (from the .sup file),
c) select a parameter and decide which
one of the variables should replace R.
Fig. 4.21 - Setting values to text strings.
Fig. 4.22 - Actions to take when non-defined parameters are found.
4.2.4.2 Run ATP
Executing the run ATP command at the top of the ATP menu or pressing the F2 function key first
will create an ATP input file with the same name as the circuit file (with extension .atp) in the
/ATP system folder. Then an ATP run will be performed via the default ATP command, which is
specified in the ATP field of the Preferences page under Tools | Options. The current ATP-file is
sent as parameter to the ATP-EMTP.
It is important to note that users do not need to select Make Names and Make File As before
running the simulation. These commands are internally executed before the ATP run. If the user
needs to do manual changes of the ATP-file and run the modified case, a new command must be
created (with the current ATP-file as parameter) using the ATP | Edit Commands... feature. After
Reference Manual
ATPDraw for Windows version 3.5 77
executing ATP, ATPDraw examines the LIS-file and displays any error or warning messages if
exist.
4.2.4.3 Edit ATP-file
This selection calls a text editor, which enables the user to contemplate or edit the ATP-file. When
the Edit File option is selected (or the F4 function key is pressed) a file having the same name as
the active circuit file with extension .atp is searched for, and will be opened in the built in Text
Editor as shown in Fig. 4.23.
Fig. 4.23 - The main window of the built in text editor.
The status bar at the bottom of the window displays the current line and column position of the
text cursor, and the buffer modified status. Basic text editing facilities (Open/Save, Print,
Copy/Paste, Find & Replace) are supported. The default text font can be changed by selecting the
Font option in the Character menu. A detailed description of all the available options can be
found in the menu options help topic. The text buffer of this editor is limited to maximum 32kB in
size, however the user can specify his own favorite text editor (wordpad.exe, write.exe,
notepad.exe) on the Preferences page of the Tools | Options dialog box.
Text Editor option in the Tools menu provides an alternative way of invoking this editor. In that
case the text buffer will initially be empty.
4.2.4.4 Edit LIS-file
This selection calls the built-in text editor, which enables the user to contemplate the LUNIT6
output of ATP (often called as LIS-file). This file has extension .lis and can be found in the
/ATP system folder following a successful simulation. In certain cases when the simulation is
halted by an operating system interrupt or a fatal error in the ATP input file (e.g. division by zero,
or I/O-xx bad character in input field) the LIS-file does not exist and can not be displayed either.
Reference Manual
78 ATPDraw for Windows version 3.5
4.2.4.5 Make File As
Generates an ATP input file for the active circuit window. User will be asked to confirm the name
of the file. Default filename is the same as that of the circuit file, but with extension .atp.
ATPDraw first calls the Make Names procedure then generates an ATP input file on the form
specified in the Settings menu.
4.2.4.6 Make Names
When this field is selected, ATPDraw examines the current circuit and gives unique names to all
nodes left blank in the active circuit window. Connected or overlapped nodes are given the same
name. Whenever a "same name on different nodes" or "duplicate names" for nodes connected by
short circuit were to be found, ATPDraw produces a warning and the user is asked to confirm this
operation. While ATPDraw establishes the node names a Generating node names message
is displayed in the middle of the current circuit window. Following Make Names, the node name
and phase sequence attributes in the Component dialog box and in the Node data window will be
updated.
IMPORTANT! All nodes will automatically receive names from ATPDraw, so the user should
normally only give names to nodes of special interest, e.g. a node which appears on the /OUTPUT
list is preferred to have a user specified name.
4.2.4.7 Edit Commands...
This feature enables to specify executable files (*.exe or *.bat) to run from the ATP menu. New
commands will appear as menu items below the Edit Commands... After clicking on the New
button of the dialog box as shown in Fig. 4.24, the user is requested to specify:
the Name of the command displayed under the ATP
menu
name and path of the executable file(*.exe or *.bat),
Parameter is the file to send as parameter when
calling the executable file.
None: No file sent as parameter
File: A file open dialog box is displayed
where the user can select a file
Current ATP: send the current ATP-file
Current PL4: send the current PL4-file
Parameter options can be selected by radio buttons. If
the File is selected, ATPDraw performs an open dialog
box, where the user can select a file name, to be sent as
parameter when executing the batch file.
Fig. 4.24 - Specifying your own executable commands.
When you completed editing the batch job settings, click on the Update button and the new
commands will be inserted into the ATP menu.
Reference Manual
ATPDraw for Windows version 3.5 79
As any other program options, the previous settings can be saved to the ATPDraw.ini file by
using the Tools | Save Options command or by selecting the Save options on exit program
options on the General page of the Tools | Options menu.
This feature can be used for many different purposes in ATP simulation: e.g. running different
ATP versions (Salford, Watcom, GNU-MingW32) within ATPDraw; running external post-
processors like TPPLOT, PCPlot or PlotXY; or launching any other data assembler.
4.2.5 Objects
This menu contains options for creating and customizing component support files. Support files
contain information on data and node values, icon and help text. Circuit objects in ATPDraw can
be either:
1. Standard components, 4. MODELS components,
2. Line/Cable (LCC) components, 5. GROUP objects,
3. BCTRAN transformer objects, 6. User specified (USP) components.
Each object has a unique support file, which includes all information about the input data and
nodes of the object, the default values of the input variables, the graphical representation of the
object and the associated help file. Each circuit object has different name internally in ATPDraw.
Support files of standard components are zipped together in a single file called ATPDraw.scl of
the main ATPDraw directory. Support files of MODELS, GROUP and USP objects have
extension .sup and are stored in system folders /MOD, /GRP and /USP, respectively. Support
files of the BCTRAN and LCC objects are stored in the Standard Component's Library
ATPDraw.scl, while other files created by ATPDraw or ATP when using these objects are
stored in the /BCT and /LCC folders. The full path of the support files are included in the data
structure of the project files, so the .sup files can be stored anywhere, but the usage of the
directory structure given below is recommended to ensure compatibility with other users:
Object type Support file(.sup) LIB file(.lib) Other (.mod,.alc,.pch)
Standard components ATPDraw.scl - -
Line/Cable components ATPDraw.scl \LCC \LCC
BCTRAN trafo objects ATPDraw.scl - \BCT
MODELS components \MOD - \MOD
GROUP objects \GRP - -
User specified components \USP \USP -
The objects support files can be edited in the Objects menu. The user can create new MODELS
and User Specified components as described in the Advanced Manual.
4.2.5.1 Edit Standard
The standard component support files stored in the ATPDraw.scl file can be customized here.
Selecting the Edit Standard field will first perform a select file dialog box of Fig. 4.25, where the
support file to be edited can be selected, then a dialog box shown in Fig. 4.26 appears.
Reference Manual
80 ATPDraw for Windows version 3.5
Fig. 4.25 - Specify the support file of the standard component to be edited.
Fig. 4.26 - Control page of object data.
On the Data page of the Edit Object dialog box, control variables of the support file (one row for
each object data) can be specified.
Name The name of the parameter. Used to identify the parameter in
the Component dialog box. This name often reflects the
name used in the ATP Rule Book.
Default Initial value of the parameter.
Min/Max Minimum/Maximum value allowed.
Param If set equal to 1, a variable text string can be assigned to the
data value. These values are assigned under ATP|Settings/Variables.
Digits Maximum number of digits allowed in the ATP-file. When high
precision is checked, $Vintage, 1 is enabled and Digits is split in
two values for high and low precision. The Digits parameter is in
version 3.0 and below used only for user specified components in
$INCLUDE statement.
An error message will appear in the Component dialog box if a parameter value is out of range. To
cancel range checking, set Min=Max (e.g. set both equal to zero).
On the Node page of the Edit object dialog box, the node attributes of the support file (one row for
each component node) can be specified.
Speed button to
the Help Editor
Speed button to
the Icon Editor
Data
Node
Reference Manual
ATPDraw for Windows version 3.5 81
Fig. 4.27 - Node control page.
Name: The name of the node. Used to identify the node in the Open Node
and Component dialog boxes.
Kind: 3-phase circuit number of the object. The number is used to handle
transposition of 3-phase nodes correctly for objects having more
than 3 phases. Kind=1 for all nodes of single phase objects.
3-phase nodes with the same Kind get the same phase sequence.
1: 1st to 3rd phase
2: 4th to 6th phase
3: 7th to 9th phase
4: 10th to 12th phase
The Kind parameter has a different meaning for MODELS or TACS
component nodes. It is used to specify the type of input/output.
MODELS node values:
0: Output node.
1: Current input node.
2: Voltage input node.
3: Switch status input node.
4: Machine variable input node.
5: TACS variable (tacs)
6: Imaginary part of steady-state node voltage (imssv)
7: Imaginary part of steady-state switch current (imssi)
8: Output from other model. Note that the model, which produces
this output, must be USEd before the current model. This can
be done by specifying a lower group number for the model and
then select the Sorting by group number option under
ATP|Settings/Misc.
TACS node values:
0: Output node.
1: Positive sum input node.
2: Negative sum input node.
3: Disconnected input node.
Pos: Specifies the node position on the icon border. The icon template
on the right hand side of Fig. 4.27 shows the possible border
positions. The position should correspond with icon drawing
(positions indicated with dark red colored lines in the Icon
Editor).
Phases: Number of phases (1 or 3) for the component node. If Phase is set
to 3 the length of the node name is limited to 5. The last
character of nodes (in the proper phase sequence according to Kind)
will be appended by ATPDraw.
The Position page of the Edit object dialog box is not yet used in ATPDraw. This option is
reserved for future use to specify the card format of the object in the .atp file.
Each circuit object has an icon, which represents the object on the screen. A speed button on the
right hand side of the Edit Object dialog box invokes the built in pixel editor where icons can be
edited. Each icon has equal width and height of 41x41 pixels on the screen.
Clicking with the left mouse button will draw the current color selected from a 16 colors palette at
the bottom. Clicking the right button will draw with the background color. Dark red colored lines
indicate the possible node positions on the icon border. Menu field items of the Icon Editor are
described in the section 4.2.6.1 of this manual.
Reference Manual
82 ATPDraw for Windows version 3.5
Each standard component has a pre-defined help file,
which can be edited by a built in Help Editor
accessible via the speed button on the right hand side
of the Edit Object dialog. Using the help editor, users
can write optional help file for the objects or add
their notes to the existing help text.
Available functions and menu field items of the Help
Editor are described in the 4.2.6.2 section of this
manual.
When the user completed all modifications on the
component data and on the icon and help files, the
new support file can be saved to disk using Save
(existing support file will be overwritten) or Save As
(new file will be created in the /USP folder) buttons.
Fig. 4.28 - Icon Editor.
4.2.5.2 New User Specified sup-file
User specified objects are either customized standard objects or objects created for the use of
$INCLUDE and Data Base Modularization feature of ATP-EMTP. The Objects | User Specified |
New sup-file menu enables the user to create a new support file for a user specified object or
customize data and node values, the icon and the help text of an existing one.
Support files of USP objects are normally located in the /USP folder. The Edit Object dialog box
opens with empty Data and Nodes tabs in this menu. Number of nodes and data must be in line
with the ARG and NUM declarations in the header section of the Data Base Module (DBM) file.
The number of data can be in the range of 0 to 36, and the number of nodes in the range of 0 to 12.
Control parameters for the object data can be entered on the Nodes and Data pages of Fig. 4.29.
Fig. 4.29 - Control page of a new user specified object.
Data
Node
Reference Manual
ATPDraw for Windows version 3.5 83
Each user specified components must have an icon, which represents the object on the screen and
may have an optional help text assigned to it, which describes the meaning of parameters. These
properties can be edited using the built in Help and Icon Editor exactly the same way as described
in session 4.2.5.1.
Finally, Save or Save As buttons can be used to save the new support file to disk. User specified
support files are normally located in the \USP folder.
4.2.5.3 Edit User Specified sup-file
An existing user specified object can be edited in the same way as any standard components as
described in session 4.2.5.1.
4.2.5.4 New Model sup-file
Usage of MODELS [4] in ATPDraw is described in the Advanced Manual. To use this feature, the
user first must write a model file using the built in Model Editor as shown in section 4.2.5.5. This
file must have a legal MODELS structure (e.g. starting with MODEL name and ending with
ENDMODEL), have an extension .mod and stored in the /MOD system folder. ATPDraw is
capable of reading such a .mod file, examining its input/output and data variables and suggesting
a support file on the correct format (see in section 4.9.9 and 5.5.2.2). If the user wants a different
icon or other node positions on the icon border, he is free to modify the default sup-file, or create a
new one by selecting the Objects | Model | New sup-file menu. This menu item will perform the
Edit Object dialog as shown in Fig. 4.30.
Fig. 4.30 - Control page for a New Model sup-file.
Name: Identifies the node in the Node and Component dialog boxes.
Kind: Specifies the input/output type of the node.
Pos: Specifies the node position on the icon border.
Phases: Number of phases must be set to 1 for all Models node. i.e. only
single-phase nodes are supported.
Data
Node
Reference Manual
84 ATPDraw for Windows version 3.5
Supported Kind values for MODELS objects are shown next:
0: Output node.
1: Current input node.
2: Voltage input node.
3: Switch status input node.
4: Machine variable input node.
5: TACS variable (tacs)
6: Imaginary part of steady-state node voltage (imssv)
7: Imaginary part of steady-state switch current (imssi)
8: Output from other model. Note that the model which produces this
output must be USEd before the current model. This can be done by
specifying a lower Group number for the model and then select the
Sorting by group number option under ATP|Settings/Misc.
The number of Nodes is the sum of inputs and outputs to the Model. The number of Data must be
equal to the number of DATA declarations of the actual Model. The Kind parameter can be
changed later in the Model node input window (right click on the node dot). All model nodes are
assumed a single-phase one. The maximum number of nodes is 12 and the maximum number of
data that can be passed into a Model is 36.
The Save or Save As buttons can be used to save the new support file to disk. Default location of
Model support files is the \MOD folder.
4.2.5.5 New Model mod-file
In addition to a support file and icon definition, each Model component needs a text file which
contains the actual Model description. This file may be created outside ATPDraw or using the
built in Model Editor. Selecting the Objects | Model | New mod-file menu, the well-known internal
text editor of ATPDraw pops-up.
ATPDraw supports only a simplified usage of MODELS. It is the task of the user to write the
model-file and ATPDraw takes care of the INPUT/OUTPUT section of MODELS along with the
USE of each model. The following restrictions apply:
Only INPUT, OUTPUT and DATA supported in the USE statement.
Not possible to call other models under USE
Exchanging data between models is rather limited (see remarks at Kind=8)
Not possible to specify HISTORY of DELAY CELLS under USE
4.2.5.6 Edit Model sup-file
A model object can be edited like any other circuit object. If the user clicks on the Objects | Model
| Edit sup-file, the well-known Edit Object dialog box appears with the model object controls.
Here the user is allowed to customize data and node values, icon and help text of the object.
4.2.5.7 Edit Model mod-file
Selecting the Objects | Model | Edit mod-file menu, the well-known internal text editor of
ATPDraw pops-up. Each model object has a .mod file which contains the description of the
model. This file can be edited inside ATPDraw using the built in Model Editor.
Reference Manual
ATPDraw for Windows version 3.5 85
4.2.6 Tools
Items under the Tools menu enable you to edit component icons or help text,
view or edit text files, customize several program options and save them to the
ATPDraw.ini file. Fig. 4.31 shows the available commands of the Tools
menu.
Fig. 4.31 - Tools menu.
4.2.6.1 Icon Editor
Brings up an icon editor shown in Fig. 4.32 where the user can edit the icon of the component. It
can be invoked either from the Edit Component dialog box or by selecting the Icon Editor option
in the Tools menu
Depending on how the editor was invoked, the file
menu provides different options. When called from
the Objects menu (Edit Standard, User Specified or
Edit Model sup-file), the user is allowed to import
icons from other support files or cancel the edit
operation and close the editor window. In this case,
the Done option in the main menu is seen to accept
and store the modified icon in the .sup file as
shown on Fig. 4.28.
When the icon editor is called from the Tools menu,
additional options like the Open and Save appears in
the File menu.
Fig. 4.32 - Icon Editor menus.
At the bottom of the editor window there is a color palette with two boxes indicating the current
foreground and background color selections, and the real-size image of the icon at right. In the
color palette, the color marked with a capital letter T is the transparent color.
To select a color from the palette, click either the left or the right mouse button in one of the color
boxes. The selected color will be assigned to the mouse button you clicked until you use the same
mouse button to select another color. The leftmost box displays the color currently assigned to the
left mouse button. The one to the right displays the color assigned to the right mouse button.
The foreground color is normally used to draw with, and the background color to erase any
mistakes made during the drawing. It is therefore convenient to assign the transparent color
(indicated by T) to the right mouse button, and desired drawing color to the left button. Mistakes
can then easily be corrected by alternating left/right mouse button clicks.
Reference Manual
86 ATPDraw for Windows version 3.5
The vertical and horizontal lines of dark red color indicate the icon node positions. These are in
the same position as indicated on the Nodes pages of the Edit Component dialog boxes.
The icon editor has a File menu, an Edit menu and a Tools menu. In addition, a Done option
appears to the right of the Tools menu if the editor has been called from the Edit Component
dialog box. Selecting Done, changes made to the icon will be accepted. Available menu options
are described below:
File options
Open Loads the icon of a support file into the icon buffer.
Save Stores the contents of the icon buffer to disk.
Import Reads the icon of a support file and inserts it into the
icon buffer.
Exit/Cancel Closes the icon editor window. If the option Exit is
selected and the icon buffer have been modified, you are
given a chance to save the icon before closing. If the Done
option is visible in the main menu, the name of this menu
item is Cancel, and the icon editor window is closed without
any warning with respect to loss of modified data.
Edit options
Undo Cancels the last edit operation.
Redo Cancels the undo command.
Cut Copies a bitmap version of the icon to the Clipboard and
clears the icon buffer. This bitmap can be pasted into other
applications (e.g. pbrush.exe).
Copy Places a bitmap version of the icon in the Clipboard.
Paste Inserts the bitmap in the Clipboard into the icon buffer. If
colors are different from those used in the original bitmap,
it is because the icon editor calculates which color in its
own color palette provides the nearest match to any bitmap
color.
Delete Clears the icon buffer.
Tools options
Pen Selects the pen drawing tool, enabling you to draw single
icon pixels, or lines or shapes by pressing and holding down
the left or right mouse button while you move the mouse.
Fill Selects the flood fill tool. Fills any shape with the
current color.
Line Selects the line drawing tool, enabling you to draw a rubber
band line by pressing and holding down the left or the right
mouse button while you move the mouse.
Circle Selects the circle drawing tool, enabling you to draw a
dynamically sized circle by pressing and holding down the
left or the right mouse button while you move the mouse.
Rectangle Selects the box drawing tool, enabling you to draw a rubber
band box by pressing and holding down the left or the right
mouse button while you move the mouse.
4.2.6.2 Help Editor/Viewer
Displays the Help Editor where the current help text assigned to components can be modified. The
Help Editor and the Viewer has actually the same window as the built-in Text Editor, but with
different menu options and capabilities. To edit help file of standard objects, the user must select
the Help Editor speed button in any Edit Component dialog boxes. In this cases a Done option
appears in the main menu and the File menu provides printing options and a Cancel choice. By
selecting Done you accept any changes made to the help text. To edit help file of a User Specified
or Model object, the user has two choices: to select the Help Editor in the Tools menu or to click
on the Help Editor speed button in any User Specified or Model dialog boxes.
Reference Manual
ATPDraw for Windows version 3.5 87
When the editor is called from the Tools menu, the File menu contains an Open and a Save option,
as well. In that case the text buffer is initially empty, so the user must select the File | Open first to
load the help text of a support file. The default font can be changed by selecting the Font option in
the Character menu. This menu will bring up the Windows standard font dialog box where you
can specify a new font name and character style, size or color. Note that ATPDraw does not
remember the current font setting when you terminate the program, so if you don't want to use the
default font, you have to specify a new one each time you start ATPDraw. The Word Wrap option
toggles wrapping of text at the right margin so that it fits in the window.
When the built in editor is used as a viewer of component help text, editing operations are not
allowed and the File menu provides printing options only. Additionally, the Find & Replace
option is missing in the Edit menu.
The status bar at the bottom of the window displays the current line and character position of the
text buffer caret, and the buffer modified status. This status bar is not visible when viewing
component help. A more detailed description of menu options is given in the next sub-section.
4.2.6.3 Text Editor
To invoke the editor you may select the Text Editor option in the Tools menu or the Edit ATP-file
or Edit LIS-file in the ATP menu. In the latter case, the file having the same name as the active
circuit file with extension .atp or .lis are automatically loaded. When the program is called
from the Tools menu, the text buffer will initially be empty.
The status bar at the bottom of the window displays the current line and character position of the
text buffer caret, and the buffer modified status. The text buffer of the built in text editor is limited
to 32kB therefore not be suitable for editing large files. However, any other text processor (e.g.
notepad.exe or wordpad.exe) can be used, if Text editor: setting of the Preferences page in the
Tools | Options menu overrides the default one.
A detailed description of the menu options are given below:
File options
New Opens an empty text buffer. (Built-in text editor only!)
Open Loads the help text of a support file or the contents of a
text file into the text buffer.
Save Stores the contents of the text buffer to disk.
Save As Stores the contents of the text buffer to a specified disk
file. (Built-in text editor only!)
Print Sends the contents of the text buffer to the default
printer.
Print Setup Enables you to define default printer characteristics.
Exit/Cancel Closes the editor or viewer window.
If the option displays Exit and the text buffer has been
modified, you are given a chance to save the text before
closing. If a Done option is available from the main menu,
this option displays Cancel, and the window will close
without any warning with respect to loss of modified data.
Edit options
Undo Cancels the last edit operation.
Cut Copies selected text to the Clipboard and deletes the text
from the buffer.
Copy Puts a copy of the selected text in the Clipboard.
Reference Manual
88 ATPDraw for Windows version 3.5
Paste Inserts the text in the Clipboard into the text buffer at
the current caret position.
Delete Deletes any selected text from the text buffer.
Select All Selects all the text in the buffer.
Find Searches the text buffer for the first occurrence of a
specified text string and jumps to and selects any matching
text found. This option displays the Windows standard Find
dialog box.
Find Next Searches for the next occurrence of the text string
previously specified in the Find dialog.
Find&Replace Searches the text buffer for one or all occurrences of a
specified text string and replaces any instance found with a
specified replacement string. This option displays
theWindows standard Replace dialog box.
Character options
Word Wrap Toggles wrapping of text at the right margin so that it fits
in the window.
Font From the Windows standard Font dialog box you can change the
font and text attributes of the text buffer.
4.2.6.4 Options
In the Tools | Options menu several user customizable program options for a particular ATPDraw
session can be set and save to the ATPDraw.ini file read by all succeeding sessions. During the
program startup, each option is given a default value. Then, the program searches for an
ATPDraw.ini file in the current directory, the directory of the ATPDraw.exe program, the
Windows installation directory and each of the directories specified in the PATH environment
variable. When an initialization file is found, the search process stops and the file is loaded. Any
option values in this file override the default settings.
The ATPDraw Options dialog enables you to specify the contents of the ATPDraw.ini file
without having to load and edit the file in a text editor. As shown on Fig. 4.33 this dialog box has
four sub-pages: General, Preferences, Directories and View/ATP.
Fig. 4.33 - Customizing program options.
Reference Manual
ATPDraw for Windows version 3.5 89
General
The General tab specifies the project file and ATPDraw main window options. The following list
describes the available options:
Option Description
Autosave every Saves all modified circuits to a separate disk file every
? minutes specified interval of minutes. The file name is the same as
the project file but with extension '.$ad'. Modified state
of the circuit window does not change as a consequence of
autosave operation.
Create backup Changes the extension of the original project file to '.~ad'
files each time the circuit is saved. This option does not apply
to autosave operations.
Save window size Records the current size and position of the main window.
and position When ATPDraw is started next, it will be displayed with
the same size and in the same position as the previous
instance.
Save window's Records the current main window state (maximized or
current state normalized). The next time ATPDraw is started, it will be
displayed in the same state.
Save toolbar Records the current view state (visible or hidden) of the
state main window toolbar, so it can be redisplayed in the same
state next time when ATPDraw is started.
Save status bar Records the current view state (visible or hidden) of the
state main window's status bar, so it can be redisplayed in the
same state next time when ATPDraw is started.
Save comment Records the current view state (visible or hidden) of the
State circuit window comment line, so it can be redisplayed in the
same state next time when ATPDraw is started.
Windows 3.1 Causes the Open/Save dialogs to be drawn in the Windows 3.1
Style style.
Save options Causes program options to be automatically saved to the
on exit initialization file when the program is terminated.
Note that the save state options will have no effect unless program options are saved to the
initialization file (ATPDraw.ini) by the Save command at the bottom of the ATPDraw Options
dialog, or by selecting the Save options on exit check box, or by the Tools | Save Options menu.
At the bottom of the ATPDraw Options dialog box the five buttons provide the following
functionality:
Option Description
OK Stores current settings into program option variables, updates the
screen and closes the dialog box. Changes made will only affect
the current session.
Save Saves the current settings to the ATPDraw.ini file.
Load Loads settings from the ATPDraw.ini file.
Apply Same as OK, but does not close the dialog box.
Help Displays the help topic related to the options on the current
page.
Note that, if no initialization file exists, ATPDraw will create a new file in its installation directory
when the user selects the Save button or the Save Options in the Tools menu.
Reference Manual
90 ATPDraw for Windows version 3.5
Preferences
On the Preferences page the user can set the size of undo/redo buffers, specify the default text
editor and command files to execute ATP-EMTP (TPBIG*.EXE) and Armafit programs.
Fig. 4.34 - Customizable program
options on the Preferences page.
Option Description
Undo/redo Specifies the number of undo and redo buffers to allocate for each
buffers: circuit window. Changing this option does not affect the currently
open circuit windows; only new windows will make use the specified
value. Almost all object manipulation functions (object create,
delete, move, rotate, etc) can be undone (or redone). These
functions also update the circuit's modified state to indicate
that the circuit needs saving. During an undo operation, the
modified state is reset its previous value, so if you undo the
very first edit operation, the 'Modified' text in the status bar
will disappear. Any operation undone can be redone. Since only a
limited number of buffers are allocated, you are never guaranteed
to undo all modifications. For example, if the number of undo/redo
buffers is set to 10 (default) and eleven successive modifications
to the circuit are made, the first modification can no longer be
undone, and the modified state will not change until you save the
circuit.
Background Selects the background color of circuit windows. The color list
color: provides available system colors, but you may customize your own
from the Windows standard Color dialog displayed by the Custom
button. The current color selection is shown in the box to the
right of the Custom button.
Text editor Holds the name and path of the text editor program to use for
program: editing ATP-files (e.g. notepad.exe or wordpad.exe). If no program
is specified (the field is empty), the built-in text editor will
be used. Note that the program specified here must accept a
filename on the command-line; otherwise the ATP-file will not be
automatically loaded by the editor.
ATP: Holds the ATP program command, which is executed by the run ATP
command (or F2 key) at the top of the ATP menu. A batch file is
suggested as default (runATP_S.bat for the Salford, runATP_W.bat
for the Watcom and runATP_G.bat for the MingW32/GNU versions).
Watcom/GNU versions can also be executed directly as %WATDIR%
TPBIGW.EXE DISK $$ * -r or %GNUDIR%TPBIGG.EXE DISK $$ s -r where
$$ replaces the %1 sign normally used in a batch file.
Reference Manual
ATPDraw for Windows version 3.5 91
ARMAFIT Holds the name of the Armafit program used for NODA line/cable
models. A batch file runAF.bat is suggested.
Directories
The following table describes the available options on the Directories page:
Option Description
Project folder The directory where ATPDraw stores the project files (.adp).
ATP folder Specifies the directory in which .atp files are created.
Model folder Directory containing support (.sup) and model (.mod) files
for MODELS components.
Group folder The container of the group object support files (.sup). The
group support files are automatically deleted when the
ATPDraw is closed.
User spec. folder Directory containing support (.sup), library (.lib) and
punch (.pch) files for user specified components.
Line/Cable folder Default folder for the line and cable models. This folder
will contain .alc files (ATPDraw line/cable data),
intermediate .atp and .pch files, and .lib files (include).
If the .alc files are stored in that directory, the
resultant .lib files used in $Include statements in the
final ATP input file are also stored in this directory. The
$Prefix/$Suffix option should in this case be turned off.
The Noda format in ATP does not allow to specify the full
path for $include files. Therefore, Noda lines (.alc files)
must be stored in the same directory as the final ATP-file.
Bctran folder The default folder for BCTRAN multi-phase, multi-winding
linear transformer models. This folder will contain .bct
files (ATPDraw Bctran data), intermediate .atp, .pch and
.lis files.
View/ATP
Two groups of options can be specified in the View/ATP page. These are the Default view options
and the Default ATP settings.
The Edit options button opens the View Options dialog, which enables
you to specify view options to apply as default to all new circuit
windows. Available options are described in section 4.2.3.9.
Note that all circuit windows maintain their own set of view options,
and only the new circuit windows you open will use the options
specified here. To change the view options of an existing circuit
window, select the Options item in the View menu (section 4.2.3.9).
Fig. 4.35 - Setting default view and ATP options.
The Edit settings button calls the ATP settings dialog described in section 4.2.4.1 of this manual.
ATP settings specified here will be applied as default to all new project files.
Note that all circuits have their own settings; stored together with the objects in the project files.
The settings specified here will only be used by the new circuits you create. To customize ATP
settings of an existing project select the Settings... item in the ATP menu or press F3 function key.
Reference Manual
92 ATPDraw for Windows version 3.5
4.2.6.5 Save Options
Saves program options into the ATPDraw.ini. This file is normally located in the program
installation directory and can be used to store default options and settings. Description of variables
in the ATPDraw.ini file is given in Appendix.
4.2.7 Window
The Window menu contains options for activating or rearranging circuit windows and showing or
hiding the Map window.
Fig. 4.36 - Supported options on the Window menu.
Tile
The Tile command arranges the circuit windows horizontally in equal size on the screen. To
activate a circuit, click the title bar of the window. The active circuit window is marked by a
symbol in front of the circuit file name.
Cascade
The Cascade command rearranges the circuit windows so that they overlap such a way that the
title bar remains visible. To activate a circuit click the title bar of the window.
Arrange Icons
The Arrange Icons command arranges the icons of minimized circuit windows so that they are
evenly spaced and don't overlap.
4.2.7.1 Map Window
The Map Window command (Shortcut: M) displays or hides the map window. The map window is
a stay-on-top style window, meaning that it will always be displayed on top of all other windows.
You can show or hide the map by pressing the M character of the keyboard to enable it when you
need it, or hide it when it conceals vital circuit window information.
The map window displays the entire contents of the active circuit. The circuit
window itself is represented by a map rectangle and the circuit objects are
drawn as black dots.
Fig. 4.37 - Map window.
When you press and hold down the left mouse button in the map rectangle, you can move it
around in the map window. When the mouse button is released, the circuit window displays the
Reference Manual
ATPDraw for Windows version 3.5 93
part of the circuit defined by the new rectangle size and position, and the circuit window scrollbars
are repositioned to reflect the updated circuit view.
If any circuit objects are currently selected when you reposition the map rectangle, selected objects
will also be moved, and their relative position retained in the new window. This functionality can
be used to quickly move a collection of objects a relatively large distance.
4.2.8 Help
The Help menu contains options for displaying the on-line help of ATPDraw, and the copyright
and version information.
Fig. 4.38 - Help menu.
ATPDraws on-line help is a standard Windows dialog, which provides help on all Main menu
options and also gives a short introduction how to build up a circuit.
4.2.8.1 Help Topics
The Help Topics command invokes the MS-Windows standard help dialog box. Several links and
a relatively large index register support the users in searching. Selecting the Contents tab you get a
lists of available help functions as shown on Fig. 4.39.
Fig. 4.39 - On-line help of ATPDraw.
Reference Manual
94 ATPDraw for Windows version 3.5
This page allows you to move through the list and select an entry on which you need help. To
display an entry select one from the list by a simple mouse click and press Display, or double click
on the entry with the mouse.
Index and Find tabs can be used to get help by the name of a topic. E.g. if you ask for help on
topics Circuit Window type this phrase into the input field of the Index page and press the
Display button. Then a description of the Circuit Window topics will be displayed as shown below
including several links marked as green underlined text:
The circuit window is the container of circuit objects. From the file menu you can load circuit objects from
disk or simply create an empty window to start building a new circuit. Circuit objects include components
(standard, user specified, MODELS and TACS), connections and relations.
The resolution of a circuit is 5000x5000 pixels (screen points); much higher than your screen normally
would support. Consequently, the circuit window displays only a small portion of the circuit. To move
around in the circuit you use the window scrollbars, or you drag the view rectangle of the map window to
another position. You may also want to use the zoom options in the view menu in order to zoom in or out
on objects.
From the components menu you select components to insert into the circuit. This menu pops up when you
click the right mouse button in an empty space of the circuit window. To start drawing a new connection,
click the left mouse button on a component node or the end-point of an existing connection. An inverted
connection line will then follow the mouse cursor until you finish the drawing operation by clicking the left
mouse button again, or canceling it by clicking the right mouse button. Relations are drawn in much the
same way, except that you have to select the TACS | Draw relation option in the components menu to
start the relation drawing operation. You can then draw multiple relations until you click the right mouse
button. Relations are used to visualize information flow into Fortran statements and are drawn as blue
connections, but have no influence on component connectivity.
To select and move an object, simply press and hold down the left mouse button on the object while you
move the mouse. Release the button and click in an empty space to unselect and confirm its new position.
The object is then moved to the nearest grid point (known as gridsnapping). If two or more components
overlap as a consequence of a move operation, you are given a warning and can choose to cancel the un-
selection.
If you select a single component and press the Crtl+F1 key combination, component specific help is
displayed.
Selecting a group of objects for moving can be done in three ways: If you hold down the Shift key while
you left-click an object, you add it to the selected objects group. Pressing and holding down the left mouse
button in an empty space enables you to drag a rectangular outline around the objects you want selected.
And finally, if you double-click the left mouse button in an empty space, you can define a polygon shaped
region by repeatedly clicking the left mouse button in the circuit window. To close the region, click the right
mouse button on the last polygon point you want to set. Objects that are defined to fall within the indicated
region or rectangle are added to the selected objects group. For components this means that the center
point of a component icon must lie within the defined region or rectangle. For connections and relations
the region or rectangle must surround both end-points. To move the selected group of objects, press and
hold down the left mouse button inside the group while you move the mouse. You unselect and confirm
the new position by clicking in an empty space. Any overlapping components will produce a warning.
Reference Manual
ATPDraw for Windows version 3.5 95
To move objects outside the visible part of the circuit, use the window scrollbars or the view rectangle in
the map window. Any selected object or group will follow the window to its new position.
You rotate objects by clicking the right mouse button inside the selected object or group. Other object
manipulation functions, such as undo/redo and clipboard options, are found in the edit menu. However,
the most frequently used object manipulation functions can be accessed by holding down the Shift key
while clicking with the right mouse button on an object or a selected group of objects. This will display and
activate the circuit window shortcut menu.
Components and component nodes can be opened for editing. If you right-click or double-click an
unselected component or node, either the Component, Open Probe or Open Node dialog box will show,
allowing you to change component or node attributes and characteristics. If you double-click in a selected
group of objects, the Open Group dialog box will show, allowing you to change attributes common to all
components in that group, such as group number and hide and lock state. Default component attributes
are stored in support files. Access to create and customize support files is provided by the objects menu.
Components are connected if their nodes overlap or if a connection is drawn between the nodes. To draw
a connection between nodes, click on a node with the left mouse button. A line is drawn between that
node and the mouse cursor. Click the left mouse button again to place the connection (clicking the right
button cancels the operation). The gridsnap facility helps overlapping the nodes. Nodes connected
together are given the same name by the Make Names and Make File options in the ATP menu. Nodes
can be attached along a connection as well as at connection end-points. A connection should not
unintentionally cross other nodes (what you see is what you get). A node naming warning appears during
the ATP file creation if a connection exists between nodes of different names or if the same name has
been given to unconnected nodes. Connections are selectable as any other object. To resize a
connection, click on its end-point with the left mouse button, hold down and drag. If several connections
share the same node, the desired connection to resize must be selected. Selected connection nodes
appear as squares at both ends of the selection rectangle.
4.2.8.2 On Main Window
The menu item On Main Window displays help about the ATPDraw main window.
4.2.8.3 About ATPDraw
Selecting this menu item shows the ATPDraw copyright information and the program version
actually used.
Fig. 4.40 - About window of ATPDraw.
Reference Manual
96 ATPDraw for Windows version 3.5
4.3 Shortcut menu
The Shortcut menu provides access to the most frequently used object manipulation functions. To
show and activate the shortcut menu, hold down the Shift key while you click the right mouse
button on an object or a selected group of objects in the circuit window. Most of the items on this
menu are identical with that of the Edit menu (section 4.2.2). The Open menu item at the top of
the menu is an addition to these normal edit functions. If this command is performed on a single
object, the Component dialog box appears. If you select this command for a group of selected
objects, the Open Group dialog box appears.
Open: Enables the component customization by bringing up
the Component dialog box of the object.
Cut, Copy: Provides access to the standard clipboard functions
Delete, Duplicate
Flip, Rotate: Rotates and flips the objects icon
Select/Unselect: Select/unselect the object(s)
Compress: replace a group of selected objects with a single icon
Extract: The group is extracted on the current circuit layer.
Edit Group: The group is extracted in a separate window. Here it
can be edited with some limitation.
Edit Circuit: Displays the circuit to which the current group
belongs.
Actually, the grouping structure can be taken as a multi-layer
circuit, where the Edit Group brings the user one step down in
details, while Edit Circuit brings one step back.
Fig. 4.41 - Available options in the Shortcut menu.
4.4 Component selection menu
The Component selection menu provides options for inserting new components into the circuit
window. This menu is normally hidden. To open it you must click on the right mouse button in an
empty area of the circuit window. The component selection menu collects all the available circuit
objects of ATPDraw in a structured way as shown in Fig. 4.42. After selecting a component in one
of the floating menus, the selected object is drawn in the circuit window.
The upper section of the menu provide access to the
probe, splitter and transposition and reference objects,
the next four to many standard ATP components: linear
and nonlinear elements, lines and cables, switches,
sources, electrical machines and transformers. The next
section is dedicated for MODELS and TACS
components. User specified objects and Frequency
dependent components for Harmonic Frequency Scan
(HFS) studies are accessible in the next group. The
lowermost section lists all the supported components in a
scrollable menu where any object can be selected upon
its support file name.
Fig. 4.42 - Component selection menu.
Reference Manual
ATPDraw for Windows version 3.5 97
4.5 Component dialog box
After selecting a component in the Component selection menu the new circuit object appears in
the middle of the circuit window enclosed by a rectangle. Click on it with the left mouse button to
move, or the right button to rotate, finally click in the open space to unselect and place the object.
The Component dialog box appears when you click the right mouse button on a circuit object (or
double click with the left mouse). Assuming you have clicked on the icon of an RLC element, a
dialog box shown in Fig. 4.43 appears. These dialog boxes have the same layout for all circuit
objects except probes, which can be edited from the Probe dialog box.
Fig. 4.43 - The Component dialog box.
Component data can be entered in the Value field of the Attributes page. The Node, Phase and
Name fields are initially empty and you are not allowed to enter values here. After having node
attributes specified by either the user in the Node dialog box, or by the Make name or Make File
As... procedure of ATPDraw the component dialog will exhibit the real values of these fields, too.
Numerical values in the data input fields can be specified as real or integer, with an optional
exponential integer, identified by 'E' or 'e'. Many data parameters have a legal range specified. To
check this legal range, place the input caret in a data field and press the Ctrl+F1 keys. If you
specify an illegal value, an error message is issued when you move to another data field, or select
the OK button. The user is also free to assign a 6 (or less) character text string as input data for
most of the standard components. Numerical values can later be assigned to these variables under
ATP|Setting/Variables using the $PARAMETER feature of ATP-EMTP (see in 4.2.4.1).
Just below the data input column, there is a Group No input field, where an optional group
number can be specified to the object. It can be used later as optional sorting criteria (the lowest
group number will be written first in the ATP-file) on the ATP | Settings / Format page.
Node names
Data values
Label on
screen
Comment in
the ATP file
Group
number
Not written to
the ATP file
High, low
precision ATP
input data
Branch
output
reuest
Local icon of
the object
(editable)
Displays the
help text of the
object
Reference Manual
98 ATPDraw for Windows version 3.5
The content of the Label input text field is written on the screen and into the project file, too. The
visibility of the component label is controlled by the Labels option in the View | Options dialog
box. The label is movable on the screen. The component dialog box has a Comment input text
field. If you specify a text in this field, it will be written to the ATP-file as a comment (i.e. as a
comment line before the data of the object).
Many standard component such as branches, non-linear, switches and transformers contains an
Output section for setting the branch output request in a combo box. Possible values are Current,
Voltage, Current&Voltage, Power&Energy or none.
Like the Group No, Label and Comment fields, the Hide and Lock buttons are common to all
components. Hidden components are not included in the ATP-file and are displayed as light gray
icons in the circuit window. The Lock option is not implemented in this version. Locked
components are meant to have fixed positions and not subject for customization.
All components where the high precision format is available has a $Vintage, 1 check button in the
component dialog box. It is thus possible to control the precision format for each individual
component. Selecting Force high resolution under the ATP | Settings/Format page will overrule
the individual setting and force $Vintage, 1 for all components if possible.
The non-linear components (non-linear branches, saturable transformers, and TACS Device 56)
have a Characteristic page too, as shown in Fig. 4.44.
Fig. 4.44 - The Characteristic page of non-linear components.
On the Characteristic tab of the dialog box, you define the input characteristic for non-linear
components. Data pairs can be specified in a standard string grid. To add new points after the
cursor position, click on Add. Delete the marked point by clicking on Delete. You can manipulate
Reference Manual
ATPDraw for Windows version 3.5 99
the order of points by the Sort button (the characteristic for non-linear components is
automatically sorted after increasing x-values, starting with the lowest number) or the
and
arrows. The user can edit the data points directly any time.
It is possible the export the characteristic to an external file or to the Windows clipboard as text.
The whole characteristic is copied (no marking is supported or required). You can also paste a
characteristic from the clipboard. It is thus possible to bring an old .atp file up in a text editor,
mark the characteristic (the flag 9999 is optional) and copy it to the clipboard, then paste it into
the characteristic page. The number of points will automatically be adjusted (the pasted
characteristic could be truncated to ensure that the number of data is less or equal to 36).
Therefore, you do not have to click on Add or Delete buttons before pasting. ATPDraw uses fixed
format 16 character columns to separate the numbers. Note! Pasting in from a text file with 'C' in
the first column is not possible; Delete leading 'C' characters first.
The File section at the bottom of the page contains an $Include field where you can specify the
name of a standard text file containing nonlinear characteristic. If the 'Include characteristic'
button is checked, this file will be referenced in the $INCLUDE statement in the ATP-file rather
than including each of the value pairs from the points table. This file must have extension .lib
and be stored in the \USP system folder if the Insert $Prefix and $Suffix cards check box is
selected in the ATP | Settings / Format menu. If the file is located outside \USP, unselect the
$Prefix and $Suffix settings and use the Browse button to specify the complete path to the file.
The nonlinear characteristic specified by the user can be displayed by clicking on the View button.
In the View Nonlinearity window (Fig. 4.45) the min and max axis values are user selectable as
well as the use of logarithmic scale (if min>0). It is also possible to copy the graphic to the
Windows clipboard in a metafile format. The Add (0,0) check box will add the origo point
graphically only. Selecting Done will close the nonlinearity display.
Fig. 4.45 - The View nonlinearity window.
Reference Manual
100 ATPDraw for Windows version 3.5
The OK button will close the dialog box and the object data and all properties are updated in the
data structure. Then the red drawing color of the object icon will be turned off, indicating that the
object now has user specified data. When you click on the Cancel button, the window will be
closed without updating. The Help button calls the Help Viewer to show the help text of the
object. Further help about the Component dialog is also available through the Windows standard
on-line help system of ATPDraw if you press the F1 key.
The following components deviate somewhat from the above description and will be referenced in
the Advaced part of this Manual:
General 3-phase transformer (GENTRAFO)
Universal machine (UM_1, UM_3, UM_4, UM_6, UM_8)
Statistical switch (SW_STAT)
Systematic switch (SW_SYST)
Harmonic source (HFS_SOUR)
BCTRAN transformer (BCTRAN3)
Line/Cable LCC objects (LCC_x)
Depending on the type of component opened, the group box in lower-left corner of the Attributes
page may display additional options:
a) you can specify here the name of the .mod file name of the MODELS object and the Use As
string. If the file name does not include a path, the file is expected to exist in the /MOD folder.
b) for the Fortran TACS components ATPDraw provides an extra OUT field here to specify the
Fortran expression.
c) for user specified components you specify the name of the library file in the $Include field. If
Send parameters option is selected, the Internal phase seq. controls how the node names are
passed. i.e. unselect this option if your library file expects 5-character 3-phase node names. If
the library file name does not include a path, the file is expected to exist in the /USP folder.
4.6 Node dialog box
In the Node data dialog box you specify data for a single component node. Input text in this dialog
boxes should contain only ASCII characters, but characters like * - + / $ etc. should not be used.
Avoid using space in the node name and lower case letters, as well. The user does not need to give
names to all nodes, in general. The name of the nodes without special interest are recommended to
be left unspecified and allow ATPDraw to give a unique name to these nodes. The node dots
given a name by the program are drawn in red, while those whose names were specified by the
user are drawn with black color.
There are four different kinds of nodes, each treated slightly different in this dialog box:
1) Standard and user specified nodes
2) MODELS object nodes
3) TACS object nodes
4) TACS controlled machine nodes
Fig. 4.46 - Node dialog box for standard components.
Reference Manual
ATPDraw for Windows version 3.5 101
Parameters common to all nodes are:
Name A six or five (3-phase components) characters long node name. The
parameter caption is read from the support file. If you try to type
in a name on the reserved ATPDraw format (XX1234 for single phase or
X1234 for three-phase nodes) you will be warned. Ignoring this
warning can result in unintentional naming conflicts.
Display If checked, the node name is written on screen, regardless of the
current setting of the Node names option in the View | Options
dialog box.
UserNamed This checkbox shows whether this node name is specified by the user
or ATPDraw. If the user wants to change a user specified node name
he must do this where the UserNamed box is checked. If not,
duplicate node name warnings will appear during the compilation.
Node with UserNamed set are also drawn with a black node dot.
The following list explains the type specific node parameters:
Standard and USP components:
Ground If checked, the node is grounded.
MODELS node:
Type 0=Output.
1=Input current (i)
2=Input voltage (v)
3=Input switch status (switch)
4=Input machine variable (mach)
5=TACS variable (tacs)
6=Imaginary part of steady-state node voltage (imssv)
7=Imaginary part of steady-state switch current (imssi)
8=Output from other model. Note that the model that produces this
output must be USEd before the current model. This is done by
specifying a lower group number for the model and then select the
Sorting by group number option under ATP | Settings / Format.
TACS node:
Type 0=Output.
1=Input signal positive sum up.
2=Input signal negative sum up.
3=Input signal disconnected. (necessary only if the node
name is user specified)
TACS controlled machine node:
Type 0=No control.
1=D-axis armature current. Out.
2=Q-axis armature current. Out.
3=Zero-sequence armature current. Out.
4=Field winding current. Out.
5=D-axis damper current. Out.
6=Current in eddy-current winding. Out.
7=Q-axis damper current. Out.
8=Voltage applied to d-axis. Out.
9=Voltage applied to q-axis. Out.
10=Zero-sequence voltage. Out.
11=Voltage applied to field winding. Out.
12=Total mmf in the machines air-gap. Out.
13=Angle between q- and d-axis component of mmf. Out.
14=Electromagnetic torque of the machine. Out.
15=Not used.
16=d-axis flux linkage. Out.
17=q-axis flux linkage. Out.
18=Angle mass. Out.
19=Angular velocity mass. Out.
Reference Manual
102 ATPDraw for Windows version 3.5
20=Shaft torque mass. Out.
21=Field voltage. In.
22=Mechanical power. In.
4.7 Open Probe dialog box
Probes are components for output of node- or branch voltages, branch current or TACS values,
and are handled differently than other components you open. In the Open Probe dialog you can
specify the number of phases of a probe and which phases to produce output in the PL4-file. There
are four different probes exist in ATPDraw:
Probe_v: Node voltages output request.
Probe_b: Branch voltage output request.
Probe_i: Branch current output request.
Probe_t: TACS variable output request. Type 33.
Fig. 4.47 - Node dialog box for standard components.
4.8 Open Group dialog box
If you double-click in a selected group of objects, the Open Group dialog box will appear,
allowing you to change attributes common to all components in that group, such as data values,
group number and hide and lock state. The common data parameters are listed in a dialog as of
Fig. 4.48 where you can change the data for all the involved components, simultaneously. The
data labels from the support files are used to classify the data.
An alternative way to change the
data parameter for several
component simultaneously is to
use $PARAMETER feature (see
Fig. 4.20 in section 4.2.4.1).
Fig. 4.48 - Open Group dialog
box for simultaneous data setting
Every component has a group number. By specifying a value in the Group No field, all
components in the selected group of objects are assigned the same number. The group number
serves as an optional sorting criterion for the ATP-file (components with the lowest group number
are written to the .atp file first).
The Hide state of multiple components can also be specified. Hidden components are not included
in the ATP-file and are displayed as gray icons. The Lock option is not yet implemented. You can
also choose to reload the default values from the support files by clicking on the now button.
Selecting the Use default values check box will cause default values to be loaded automatically
next time the dialog box is opened.
Reference Manual
ATPDraw for Windows version 3.5 103
4.9 Circuit objects in ATPDraw
The Component selection menu provides options for creating and
inserting new components into the circuit window. This menu is
normally hidden. To show and activate the menu, click the right mouse
button in an empty circuit window space. Following a selection in one
of the floating sub-menus, the selected object will be drawn in the
center of the active circuit window enclosed by a rectangle. You can
move (left mouse click and drag), rotate (right mouse button) or place
the object (click on open space).
The Component selection menu has several sub-menus; each of them
include circuit object of similar characteristics as briefly described
below:
Fig. 4.49 - Component selection menu.
Probes & 3-phase
o Probes for node voltage-, branch voltage, current-, and TACS monitoring
o Various 3-phase transposition objects
o Splitter (coupling between 3-phase and single phase circuits)
o ABC/DEF Reference objects for specifying the master node for phase sequence
Branches
o Branch linear: 1-phase and 3-phase non-coupled components
o Branch nonlinear: 1-phase nonlinear R and L components. Single and 3-phase MOV. Type-
93, 96 and 98 nonlinear inductors including initial conditions for the fluxlinked reactors
o TACS controlled and time dependent resistor
Lines/Cables
o Lumped, PI-equivalents (type 1, 2...) and RL coupled components (type 51, 52...)
o Distributed lines of constant, frequency independent parameters. Transposed (Clarke) up to
9-phases, untransposed 2 or 3-phase (KCLee) line models.
o LCC, the user can select 1-9 phase models of lines/cables. In the input menu of these
components, the user can specify a LINE CONSTANT or CABLE PARAMETER data case.
The resulting include file contains the electrical model and the LIB-file is generated
automatically if the ATP setup is correct. Bergeron (KCLee/Clarke), nominal PI, JMarti,
Semlyen and Noda models are supported.
o Read PCH-file. This is a module in ATPDraw to read the punch-files from Line Constants,
Cable Constants or Cable Parameters and to create an ATPDraw object automatically (sup-
file and lib-file). ATPDraw recognizes: PI-equivalents, KCLee, Clarke, Semlyen, and JMarti
line formats.
Switches
o Time and voltage controlled. 3-phase time controlled switch
o Diode, thyristor, triac
o Simple TACS controlled switch
o Measuring switch
o Statistic and systematic switches
Reference Manual
104 ATPDraw for Windows version 3.5
Sources
o AC and DC sources, 3-phase AC source. Ungrounded AC and DC sources.
o Ramp sources
o Surge sources
o TACS controlled sources
Machines
o Type 59 synchronous machine
o Universal machines (type 1, 3, 4, 6, and 8)
Transformers
o Single phase and 3-phase ideal transformer
o Single phase saturable transformer
o 3-phase, two- or three-winding saturable transformer
o 3-phase, two winding saturable transformer, 3-leg core type of high homopolar reluctance
o BCTRAN. Automatic generation of .pch file. 1-3 phases, 2-3 windings. Auto-transformers,
Y-, and D- connections with all possible phase shifts. External nonlinear magnetizing
inductance(s) supported.
MODELS
o Under MODELS the user can select a model component either by specifying a sup-file or a
mod-file. If a .mod-file is selected the corresponding sup-file required by ATPDraw is
created automatically (if the model is recognized successfully). A mod-file is a text file in
the MODELS language. The mod-file must have a name equal to the name of the model.
The following restrictions apply when ATPDraw reads a mod-file:
- Not allowed with indexed input, output or data variables.
- Names of all input, output and data variables must be less than 6 characters.
Only input, output, data and variables declared in front of TIMESTEP, INTERPOLATION,
DELAY, HISTORY, INIT and EXEC are recognized by ATPDraw when reading the mod-
file.
o Type 94: When selecting this menu item the user is requested to specify a mod-file
describing the Type-94 models component. ATPDraw then examines this file and creates
the required sup-file for the component. The same rules as specified under MODELS apply.
ATPDraw does not check if the format of the mod-file corresponds to Type-94 declarations.
TACS
o Coupling to Circuit. Input to TACS from the circuit must be connected to this object.
o 4 types of TACS sources: DC, AC, Pulse, Ramp.
o Transfer functions: General Laplace transfer function. If the Limits are not specified or
connected, no limits apply. Simple Integral, Derivative, first order Low and High Pass
transfer functions.
o TACS devices. All devices except Type-55.
o Initial condition for TACS objects (Type-77)
o Fortran statements: General Fortran statement (single line expression). Simplified Math
statements or Logical operators.
o Draw relations. Relations are drawn in blue and are used just to visualize connections
between Fortran statements and other objects. Relations will not affect the ATP input file.
Reference Manual
ATPDraw for Windows version 3.5 105
User specified
o Library: $Include is used to include the lib-file into the ATP input file. The user must keep
track of internal node names in the include file.
o Files: $Include is used to include the user specified lib-file into the ATP input file and pass
node names and data variables as parameters. Each user specified objects must have a sup-
file containing an icon, specification of data and node parameters, and a lib-file describing
the component in the Data Base Module format of ATP.
o Single and 3-phase reference: These objects are not represented in the ATP input data file
and serve only as visualization of connectivity.
Frequency components
o Harmonic source for Harmonic Frequency Scan studies
o Single and 3-phase frequency dependent loads in CIGR format
o Single phase RLC element with frequency dependent parameters
Standard Component..
o Complete list of standard components in alphabetical order sorted by support file names.
4.9.1 Probes & 3-phase
The menu Probes & 3-phase appears when the mouse moves over this
item in the Component selection menu or when the user hits the P
character.
Probes are components for monitoring the node or branch voltage, branch
current or TACS values. In the Open Probe dialog you can specify the
number of phases to connect to and select phases to be monitored.
Fig. 4.50 - Drawing objects on the Probe & 3-phase menu.
Probe Volt
Selecting this field draws the voltage probe to specify a node voltage-to-ground output
request in the ATP-file.
Probe Branch volt.
Selecting this field draws the branch voltage probe to specify a branch voltage output
requests in the ATP-file. ATPDraw inserts a 1E+9 ohm resistance.
Probe Curr
Selecting this field inserts a current probe (measuring switch) into the circuit to specify
current output request in column 80 in the ATP-file. The number of monitored phases are
user selectable.
Probe Tacs
Selecting this field draws the Tacs probe to specify signal output and inserts TACS Type-
33 object into the ATP-file.
Reference Manual
106 ATPDraw for Windows version 3.5
Splitter
The Splitter object is a transformation between a 3-phase node and three 1-phase nodes.
The object has 0 data and 4 nodes. The object can be moved, rotated, selected, deleted,
copied and exported as any other standard components.
When a splitter is rotated the phase sequence of the single-phase side
changes as shown left.
If a name is given to the 3-phase node, the letters A B C are added
automatically on the single-phase side of splitters.
Note! Do not give names to nodes at the single-phase side of splitters and do not connect splitters
together on the single-phase side. I.e. next examples are illegal!
disconnection is illegal this way! transposition is illegal this way!
Transp 1 ABC-BCA ...Transp 4 ABC-ACB
Transposition objects can be used to change the phase sequence of a 3-phase node. The following
transpositions are supported:
Change the phase sequence from ABC to BCA.
Change the phase sequence from ABC to CAB.
Change the phase sequence from ABC to CBA.
Change the phase sequence from ABC to ACB.
Handling of transpositions for objects with several 3-phase nodes can be accomplished by
specifying a circuit number Kind under Objects | Edit Standard / Nodes (see in 4.2.5.1). 3-phase
nodes having the same Kind will receive the same phase sequence.
ABC reference
When attached to a 3-phase node in the circuit this node becomes the "master" node with
phase sequence ABC. The other nodes will adapt this setting.
DEF reference
When attached to a 3-phase node in the circuit this node becomes the "master" node with
phase sequence DEF. The other nodes will adapt this setting. A combination of ABC and
DEF references is possible for e.g. in 6-phase circuits.
4.9.2 Branch Linear
This sub-menu contains linear branch components. The name and the icon of linear branch
objects, as well as a brief description of the components are given next in tabulated form. Data
parameters and node names to all components can be specified in the Component dialog box (see
Fig. 4.43), which appears if you click on the icon of the component with the right mouse button in
the circuit window.
Reference Manual
ATPDraw for Windows version 3.5 107
The Help button on the Component dialog boxes calls the Help Viewer in which
a short description of parameters and a reference to the corresponding ATP Rule
Book chapter is given. As an example, Fig. 4.52 shows the help information
associated with the ordinary RLC branch.
Fig. 4.51 - Supported linear branch elements.
Selection Object name Icon ATP card Description
Resistor
RESISTOR
BRANCH
type 0
Pure resistance in W.
Capacitor
CAP_RS
BRANCH
type 0
Capacitor with damping resistor.
C in mF if Copt=0.
Inductor
IND_RP
BRANCH
type 0
Inductor with damping resistor.
Inductance in mH if Xopt=0.
RLC
RLC
BRANCH
type 0
R, L and C in series.
RLC 3-ph
RLC3
BRANCH
type 0
3-phase R, L and C in series.
Independent values in phases.
RLC-Y 3-ph
RLCY3
BRANCH
type 0
3-phase R, L and C, Y coupling.
Independent values in phases.
RLC-D 3-ph
RLCD3
BRANCH
type 0
3-phase R, L and C, D coupling.
Independent values in phases.
C : U(0)
CAP_U0
BRANCH +
initial condition
Capacitor with initial condition.
L : I(0)
IND_I0
BRANCH +
initial condition
Inductor with initial condition.
Fig. 4.52 - Help information associated with the series RLC object.
Reference Manual
108 ATPDraw for Windows version 3.5
4.9.3 Branch Nonlinear
This menu contains the supported nonlinear resistors and inductors. All the objects except the
TACS controlled resistor can also have a nonlinear characteristic. These attributes can be
specified by selecting the Characteristic tab of the Component dialog boxes as shown in Fig. 4.44.
The nonlinear characteristic of objects can be entered as piecewise linear interpolation. The
number of data points allowed to enter on the current/voltage, current/flux or time/resistance
characteristics are specified in the Help file of objects.
U/I characteristics of nonlinear resistances are assumed symmetrical, thus
(0, 0) point should not be entered. If the saturation curve of a nonlinear
inductor is symmetrical start with point (0, 0) and skip the negative points.
The hysteresis loop of Type-96 reactors is assumed symmetrical, so only the
lower loop of the hysteresis must be entered. The last point should be where
the upper and lower curves meet in the first quadrant. If you specify a metal
oxide arrester with MOV Type-92 component, ATPDraw accepts the
current/voltage characteristic and performs an exponential fitting in the log-
log domain to produce the required ATP data format.
Fig. 4.53 - Nonlinear branch elements.
Selection Object name Icon ATP card Description
R(i) Type 99
NLINRES
BRANCH
type 99
Current dependent resistance.
L(i) Type 98
NLININD
BRANCH
type 98
Current dependent inductor.
L(i) Type 93
NLIND93
BRANCH
type 93
True non-linear current
dependent inductor.
L(i) Type 96
NLIND96
BRANCH
type 96
Pseudo-nonlinear hysteretic
inductor.
R(t) Type 97
NLINR_T
BRANCH
type 97
Time dependent resistor.
MOV Type 92
MOV
BRANCH
type 92
Current dependent resistance on
exponential form.
MOV Type 3-ph
MOV_3
BRANCH
type 92
3-phase current dependent
resistance.
R(TACS) Type 91
TACSRES
BRANCH
type 91
TACS / MODELS controlled
time dependent resistor.
L(i) Type 98, init
NLIN98_I
BRANCH
type 98
Current-dependent inductor.
with initial flux.
L(i) Type 96, init
NLIN96_I
BRANCH
type 96
Pseudo-nonlinear hysteretic
inductor with initial flux.
L(i) Type 93, init
NLIN93_I
BRANCH
type 93
True non-linear inductor with
initial flux.
Reference Manual
ATPDraw for Windows version 3.5 109
4.9.4 Lines/Cables
The Lines/Cables menu has several sub-menus for different types of line models. Available line
models are: Lumped parameter models (RLC p, RL coupled), distributed parameter lines with
constant (i.e. frequency independent) parameters, lines and cables with constant or frequency
dependent parameters (Bergeron, PI, JMarti, Noda or Semlyen), calculated by means of the LINE
CONSTANTS, CABLE CONSTANTS or CABLE PARAMETERS supporting routine of ATP-EMTP.
Fig. 4.54 - Line models with lumped parameters.
4.9.4.1 Lumped parameter line models
RLC Pi-equiv. 1: These line models are simple, lumped, non-symmetric p-equivalents of ATP
Type 1, 2, 3 etc. branches of ATP.
RL Coupled 51: These line models are simple, lumped, non-symmetric mutually RL coupled
components of Type-51, 52, 53 etc. branches of ATP.
RLC Sym. 51: These line models are symmetric with sequence value input. The line models
are special applications of the RL coupled line models in ATP. The following
selections are available on the three pop-up menus:
Selection Object name Icon ATP card Description
RLC Pi-equiv. 1
+1 phase
LINEPI_1
BRANCH
type 1
Single phase RLC p-equivalent.
RLC Pi-equiv. 1
+ 2 phase
LINEPI_2
BRANCH
type 1-2
2-phase RLC p-equivalent
Non-symmetric.
RLC Pi-equiv. 1
+ 3 phase
LINEPI_3
BRANCH
type 1-3
3-phase RLC p-equivalent
Non-symmetric. 3-phase nodes.
RL Coupled 51
+ 2 phase
LINERL_2
BRANCH
type 51-52
2-phase RL coupled line model.
Non-symmetric.
RL Coupled 51..
+ 3 phase
LINERL_3
BRANCH
type 51-53
3-phase RL coupled line model.
Non-symmetric. 3-phase nodes.
RL Coupled 51..
+ 6 phase
LINERL_6
BRANCH
type 51-56
2x3 phase RL coupled line
model. Non-symmetric. Off-
diagonal R is set to zero.
RL Sym. 51
+ 3 ph
LINESY_3
BRANCH
type 51-53
3-phase RL coupled line model
with sequence impedance (0, +)
input. Symmetric.
RL Sym. 51
+ 6 ph
LINESY_6
BRANCH
type 51-56
2x3-phase RL coupled line
model with sequence impedance
(0, +) input. Symmetric.
Reference Manual
110 ATPDraw for Windows version 3.5
4.9.4.2 Distributed parameter line models
Selecting Distributed opens a popup menu where two different types of line models can be
selected: Transposed lines or Untransposed lines. Both of that are distributed parameters,
frequency independent lines.
Fig. 4.55 - Distributed transmission line models.
Transposed lines (Clarke): These components can be characterized as symmetrical, distributed
parameter and lumped resistance models (called as Clarke-type in the ATP Rule-Book). Six
different types are supported:
Selection Object name Icon ATP card Description
Transposed lines
+ 1 phase
LINEZT_1
BRANCH
type -1
Single phase, distributed parameter
line, Clarke model.
Transposed lines
+ 2 phase
LINEZT_2
BRANCH
type -1.. -2
2-phase, distributed parameter,
transposed line, Clarke model.
Transposed lines
+ 3 phase
LINEZT_3
BRANCH
type -1.. -3
3-phase, distributed parameter,
transposed line, Clarke model.
Transposed lines
+ 6 phase
LINEZT6N
BRANCH
type -1.. -6
6-phase, distributed parameter,
transposed line, Clarke model.
Transposed lines
+ 6 phase mutual
LINEZT_6
BRANCH
type -1.. -6
2x3 phase, distributed Clarke line.
with mutual coupling between the
circuits.
Transposed lines
+ 9 phase
LINEZT_9
BRANCH
type -1.. -9
9-phase, distributed parameter,
transposed line, Clarke model.
Untransposed lines (KCLee): Parameters of these nonsymmetrical lines are usually generated
outside ATPDraw. These components can be characterized as untransposed, distributed parameter
and lumped resistance models with real or complex modal transformation matrix (called as
KCLee-type in the ATP Rule-Book). Double-phase and 3-phase types are supported:
Selection Object name Icon ATP card Description
Untransposed lines
(KCLee)+ 2 phase
LINEZU_2
BRANCH
2-phase, distributed parameters,
untransposed (KCLee) line model
with complex transformation matrix.
Untransposed lines
(KCLee)+ 3 phase
LINEZU_3
BRANCH 3-phase, distributed parameters,
untransposed (KCLee) line model
with complex transformation matrix
Reference Manual
ATPDraw for Windows version 3.5 111
4.9.4.3 LCC objects
In this part of the program, you specify the geometrical and
material data for an overhead line or a cable and the
corresponding electrical data are calculated automatically by the
LINE CONSTANTS, CABLE CONSTANTS or CABLE PARAMETERS
supporting routine of ATP-EMTP.
Fig. 4.56 - LCC supports line modeling up to 9 phases.
To use the LCC module of ATPDraw the user must first select a line/cable component with the
desired number of phases (1..9). This will display an object in the circuit window that can be
connected to the circuit as any other component. Clicking on this component with the right mouse
button will bring up a special input dialog box called Line/Cable Data dialog box with two sub-
pages: Model and Data, where the user selects between the supported System type:
o Overhead Line: LINE CONSTANTS
o Single Core Cables: CABLE PARAMETERS or CABLE CONSTANTS
o Enclosing Pipe: CABLE PARAMETERS or CABLE CONSTANTS
and Model type of the line/cable :
o Bergeron: Constant parameter KCLee or Clark models
o PI: Nominal PI-equivalent (short lines)
o JMarti: Frequency dependent model with constant transformation matrix
o Noda: Frequency dependent model
o Semlyen: Frequency dependent simple fitted model.
The Line/Cable Data dialog box completely differs from the Component dialog box of other
components, therefore it is described in chapter 5.3 of the Advanced Manual.
Selection Object name Icon ATP card Description
LCC + 1 phase
Line/Cable
$Include Single phase LCC object.
LCC + 2 phase
Line/Cable
$Include 2-phase LCC object.
LCC + 3 phase
Line/Cable
$Include 3-phase LCC object.
... ... ... ... ...
LCC + 6 phase
Line/Cable
$Include 2x3-phase LCC object.
LCC + 7 phase
Line/Cable
$Include 7-phase LCC object.
LCC + 8 phase
Line/Cable
$Include 8-phase LCC object.
LCC + 9 phase
Line/Cable
$Include 3x3-phase LCC object.
Reference Manual
112 ATPDraw for Windows version 3.5
4.9.4.4 Read PCH file...
ATPDraw is able to read the .pch output files obtained by external run of ATP-EMTP's LINE
CONSTANTS or CABLE CONTSTANTS supporting routines. Selecting the Read PCH file... menu
item, the program performs an Open Punch File dialog in which the available .pch files are
listed. If you select a file and click Open, ATPDraw attempts to read the file and if succeed in
creates a .lib file in the \USP folder in the Data Base Module format of ATP. When the .lib
file is successfully created, the icon of the new LCC component appears in the middle of the
circuit window.
Fig. 4.57 - Results of pch-file reading are communicated in dialog boxes.
4.9.5 Switches
ATPDraw supports most of the switch type elements in ATP, such as
ordinary time- or voltage-controlled switches, options for modeling
diodes, valves and triacs, as well as measuring and statistical switches.
The Switches sub-menu contains the following switch objects:
Fig. 4.58 - Supported switch type ATP components.
Selection Object name Icon ATP card Description
Switch time
controlled
SWITCHTC
SWITCH
type 0
Single phase time controlled switch.
Switch time 3-ph
SWIT_3XT
SWITCH
type 0
Three-phase time controlled switch,
Independent operation of phases.
Switch voltage
contr.
SWITCHVC
SWITCH
type 0
Voltage controlled switch.
Diode (type 11)
DIODE
SWITCH
type 11
Diode. Switch type 11. Uncontrolled.
Reference Manual
ATPDraw for Windows version 3.5 113
Selection Object name Icon ATP card Description
Valve (type 11)
VALVE
SWITCH
type 11
Valve/Thyristor. Switch type 11.
TACS/MODELS- controlled.
Triac (type 12)
TRIAC
SWITCH
type 12
Double TACS/MODELS controlled
switch.
TACS switch
(type 13)
TACSSWIT
SWITCH
type 13
Simple TACS/MODELS controlled
switch.
Measuring
SWMEAS
SWITCH
type 0
Measuring switch.
Current measurements.
Statistic switch
SW_STAT
SWITCH Statistic switch.
See ATP | Settings / Switch/UM.
Systematic switch
SW_SYST
SWITCH Systematic switch.
See ATP | Settings / Switch/UM.
4.9.6 Sources
The popup menu under Sources contains the following items:
Fig. 4.59 - Electrical sources in ATPDraw.
Selection Object name Icon ATP card Description
DC type 11
DC1PH
SOURCE
type 11
DC step source. Current or voltage.
Ramp type 12
RAMP
SOURCE Ramp source. Current or voltage.
Slope-Ramp
type 13
SLOPE_RA
SOURCE
type 13
Two-slope ramp source.
Current or voltage.
AC type 14
AC1PH
SOURCE AC source. Current or voltage.
Surge type 15
SURGE
SOURCE Double exponential source Type-
15.
Heidler type 15
HEIDLER
SOURCE Heidler type source. Current or
Volt.
TACS source
TACSSOUR
SOURCE
type 60
TACS/MODELS controlled source.
Current or voltage.
AC 3-ph. type 14
AC3PH
SOURCE
type 14
AC source.
Current or voltage. 3-phase node.
AC Ungrounded
AC1PHUG
SOURCE
type 14+18
Ungrounded AC source.
Voltage only.
DC Ungrounded
DC1PHUG
SOURCE
type 11+18
Ungrounded DC source.
Voltage only.
Reference Manual
114 ATPDraw for Windows version 3.5
4.9.7 Machines
Two categories of electrical machines are available in
ATPDraw: Synchronous Machines and Universal Machines.
ATPDraw does not support machines in parallel or back-to -
back.
Fig. 4.60 - Supported electric machine alternatives.
The Synchronous Machine models in ATPDraw have the following features/limitations:
With and without TACS control.
Manufacturers data.
No saturation.
No eddy-current or damping coils.
Single mass.
The Universal Machine models in ATPDraw have the following features/limitations:
Manual and automatic initialization.
SM, IM and DC type supported.
Raw coil data (internal parameters).
Saturation is supported in d, q, or both axes.
One single excitation coil in each axis (d, q).
Network option for mechanical torque only.
Single torque source.
The Component dialog box of Universal Machines is significantly different than that of the other
objects. A complete description of parameters in this dialog box is given in chapter 5.7.2 of the
Advanced Manual.
The popup menu under Machines contains the following items:
Selection Object name Icon ATP card Description
SM 59
+ No control
SM59_NC
MACHINE
type 59
Synchronous machine. No TACS
control. 3-phase armature.
SM 59
+ 8 control
SM59_FC
MACHINE
type 59
Synchronous machine. Max. 8
TACS control. 3-phase armature.
UM1
Synchronous
UM_1
UM-MACHINE
type 1
Synchrounous. Set initialization
under ATP | Settings/Switch/UM.
UM3
Induction
UM_3
UM-MACHINE
type 3
Induction. Set initialization under
ATP | Settings/Switch/UM.
UM4
Induction
UM_4
UM-MACHINE
type 4
Induction. Set initialization under
ATP | Settings/Switch/UM.
UM6 Single
phase
UM_6
UM-MACHINE
type 6
Single phase. Set initialization
under ATP | Settings/Switch/UM.
UM8 DC
UM_8
UM-MACHINE
type 8
DC machine. Set initialization
under ATP | Settings/Switch/UM.
Reference Manual
ATPDraw for Windows version 3.5 115
4.9.8 Transformers
Fig. 4.61 - Transformer models in ATPDraw.
The popup menu under Transformers contains the following items:
Selection Object name Icon ATP card Description
Ideal 1 phase
TRAFO_I
SOURCE
type 18
Single-phase ideal transformer.
Ideal 3 phase
TRAFO_I3
SOURCE
type 18
3-phase ideal transformer.
Saturable
1 phase
TRAFO_S
BRANCH
TRANSFORMER
Single-phase saturable transformer.
Saturable
3 phase
GENTRAFO
BRANCH
TRANSFORMER
General saturable transformer.
3-phase. 2 or 3 windings.
# Sat. Y/Y 3-leg
TRAYYH_3
BRANCH
TRANSFORMER
THREE PHASE
3-phase saturable transformer. High
homopolar reluct. (3-leg). 3-ph node.
Preprocessing of manufacturer data.
BCTRAN
BCTRAN
BRANCH
Type 1...9
Direct support of BCTRAN transformer
matrix modeling.
The characteristic of the nonlinear magnetizing branch of the three saturable-type transformers can
be given in the Characteristic tab of the component dialog box. The saturable transformers have
an input window like the one in Fig. 4.44. In this window the magnetizing branch can be entered
in I
RMS
/U
RMS
or I
A
/FLUX
Vs
coordinates. The RMS flag on the Attributes page select between the
two input formats. If the Include characteristic check box is selected on the Attributes page, a disk
file referenced in the $Include field will be used in the ATP input file. If the nonlinear
characteristic is given in I
RMS
/U
RMS
, ATPDraw will calculate the flux/current values automatically
and use them in the final ATP input file.
The BCTRAN transformer component provides direct support of BCTRAN transformer matrix
modeling. The user is requested to specify input data (open circuit and short circuit factory test
data) in BCTRAN supporting routine format, then ATPDraw performs an ATP run to generate a
punch-file that is inserted into the final ATP-file describing the circuit. The user can specify where
the factory test was performed and where to connect the excitation branch. The excitation branch
can be linear or non-linear. In the latter case, the nonlinear inductors must be connected to the
winding closest to the iron core as external elements.
The BCTRAN dialog and the Component dialog box of the Saturable 3-phase GENTRAFO differ in
many ways from the input data window of other objects. A more comprehensive description of the
input parameters is given in chapters 5.6 and 5.7.1 of the Advanced Manual, respectively.
Reference Manual
116 ATPDraw for Windows version 3.5
4.9.9 MODELS
Besides the standard components, the user can create his/her own models using the MODELS
simulation language in ATP [4]. ATPDraw supports only a simplified usage of MODELS. The
user writes a model-file and ATPDraw takes care of the INPUT/OUTPUT section of MODELS
along with the USE of each model. The following restriction applies:
Only INPUT, OUTPUT and DATA supported in the USE statement.
Not possible to call other models under USE
Exchanging data between models is restricted (see remarks in 4.2.5.4)
Not possible to specify HISTORY of DELAY CELLS under USE
Using this feature requires knowledge about the syntax and general structure of MODELS
language. There are two options for creating a model object in ATPDraw:
to create a support file manually under Object | Model | New sup-file.
to select a .mod file directly under MODELS in the selection menu.
The Advanced part of this Manual gives detailed information about both procedures and a general
overview about the use of MODELS in ATPDraw. In this chapter only the automatic support file
generation is introduced. The process normally consists of two steps:
1. To create a model file (.mod) containing the actual model description.
2. To load this file via the Files (sup/mod)... or Type 94 sub-menus under MODELS
Fig. 4.62 - Options under the MODELS sub-menu.
Files (sup/mod)...
Selecting MODELS | Files (sup/mod)... in the component selection menu performs an Open Model
dialog box where the user can choose a model file name or a support file name. These files are
normally stored under the /MOD folder. If a .mod file was selected ATPDraw interprets the file as
shown in Fig. 4.63 and creates a support file (.sup) for it. If the support file already exists, i.e. it
has been created manually by the user under the Object | Model | New sup-file or by ATPDraw
earlier, the new model object appears immediately in the circuit window, i.e. the Information
dialog does not show up.
Fig. 4.63 - Interpretation of the model.
The Component dialog box of model objects has a new input section Models below the DATA and
NODES attributes as shown in Fig. 4.64. This new section has two input fields: Model file for
locating the model description file and a Use As field for specification of the model_name in the
USE model AS model_name statement of MODELS.
Reference Manual
ATPDraw for Windows version 3.5 117
The input/output to MODELS, the use of the model and interfacing it with the rest of the circuit
are handled by ATPDraw, automatically. Model descriptions are written directly in the ATP file
instead of using $Include. Blank lines are removed when inserting the model file in the ATP-file.
The general structure of the MODELS section in the .atp input file is shown below:
MODELS
/MODELS
INPUT
IX0001 {v(U1_ZNO)}
IX0002 {v(U2_ZNO)}
IX0003 {v(I_ZNO )}
OUTPUT
TRIP_A
MODEL FLASH_1
------------------------------------------
Description of the model. A .mod file e.g.
D:\ATPDraw3\Mod\Flash_1.mod is pasted here
------------------------------------------
ENDMODEL
USE FLASH_1 AS FLASH_1
INPUT
V1:= IX0001
V2:= IX0002
iczn:= IX0003
DATA
Pset:= 1.
Eset:= 10.
fdel:= 5.
fdur:= 20.
OUTPUT
TRIP_A:=trip
ENDUSE
ENDMODELS
Fig. 4.64 - The component dialog box of model object FLASH_1.
Reference Manual
118 ATPDraw for Windows version 3.5
Type 94 + 1 phase ... 3 phase
Selecting MODELS | Type 941+ 1...3 phase in the component selection menu performs an Open
Model dialog box where the user can choose a Type-94 compatible .mod file. These files are
normally stored under the /MOD folder. Depending on the selected phase, ATPDraw associates
the corresponding Type-94 .sup file with the model then interprets the number of input data as
shown in Fig. 4.65.
Fig. 4.65 - Interpretation of the Type-94 model file.
The Component dialog box of Type-94 model objects has a new input section Type 94 besides the
DATA and NODES attributes (see on Fig. 4.66). This new section has three input fields: THEV,
ITER and NORT to specify the solution method for ATP when interfacing the Type-94 object with
the rest of the electrical network, and a Use As field for specification of the name of the model
referenced in the Type-94 declaration of the ATP input file.
Fig. 4.66 - Component dialog box of Type-94 model objects.
Signal input and data values for a Type-94 object are loaded by ATP and the output of the object
are also used automatically by ATP. Interfacing it with other components of the circuit is handled
by ATPDraw. A Type-94 compatible .mod files must have a fixed structure and the use of such
an object also requires special declarations in the ATP input file as shown next:
Structure of a Type-94 compatible .mod file:
Reference Manual
ATPDraw for Windows version 3.5 119
MODEL ind1n
comment ----------------------------------------------------------------
| _______ |
| Internal circuit: 1-ground : L1 | | |
| 1 o | |
| |_______| |
| _|_ |
| - ground |
| |
| Built for use as a 1-phase non-transmission type-94 Norton component |
------------------------------------------------------------- endcomment
comment ----------------------------------------------------------------------
| First, declarations required for any type-94 iterated model |
| (the values of these data and input are loaded automatically by ATP) |
| (the values of these outputs are used automatically by ATP) |
| (DO NOT MODIFY THE SEQUENCING OF THE DATA, INPUT, AND VAR IN THIS GROUP) |
| (the names may be modified, except 'n') |
| (when built for n=1, the array notation is not required) |
------------------------------------------------------------------- endcomment
DATA n -- number of phases
ng {dflt: n*(n+1)/2} -- number of conductances
INPUT v -- voltage(t) at terminal 1
v0 -- voltage(t=0) at terminal 1
i0 -- current(t=0) into terminal 1
VAR i -- current(t) into terminal 1
is -- Norton source(t+timestep) at terminal 1
g -- conductance(t+timestep) at terminal 1
flag -- set to 1 whenever a conductance value is modified
OUTPUT i, is, g, flag
comment ----------------------------------------------------------------------
| Next, declarations of user-defined data for this particular model |
| (values which must be defined when using this model as a type-94 component) |
------------------------------------------------------------------- endcomment
DATA L1 -- [H] reference value of inductance L
comment ----------------------------------------------------------------------
| Next, declarations private to the operation of this model |
------------------------------------------------------------------- endcomment
VAR st -- used for converting Laplace s to time domain
L -- [H] variable value of inductance L
INIT
st := 2/timestep -- trapezoidal rule conversion from Laplace
L := L1 -- initialize variable inductance value
g:= 1/(st*L) -- conductance converted from Laplace 1/sL
ENDINIT
EXEC -- L is constant in this example
IF t=0 THEN
flag := 1 -- conductance values have been changed
i := i0 -- t=0 current through L
is := -i0 -g*v0 -- history term for next step
ELSE
flag := 0 -- reset flag
i := g*v -is -- applying trapezoidal rule, calculate from v(t)
is := -i -g*v -- history term from trapezoidal rule, for next step
ENDIF
ENDEXEC
ENDMODEL
The use of a Type-94 Norton model in the ATPDraw generated input file is shown next. The
Type-94 declaration refers to the Use As name of the MODEL in which the operation of the object
is described:
C Time varying inductor
94TOP BOT IND1N NORT 1
>DATA L1 0.1
>SSV SS_TOP
>SSV SS_BOT
>SSI SS_I
>END
Reference Manual
120 ATPDraw for Windows version 3.5
4.9.10 TACS
The TACS menu gives access to most type of TACS components of ATP. Exceptions are Device
55 and multi-line Fortran statements ($ continuation), which are not supported. The TACS sub-
menu on the component selection menu contains the following items:
Fig. 4.67 - Supported TACS objects.
4.9.10.1 Coupling to circuit
The Coupling to circuit object provides an interface for TACS HYBRID simulations. This
object must be connected with an electrical node to pass node voltages, or the branch currents /
switch status to TACS. The type of the variable sent to TACS is controlled by the Type settings in
the EMTP_OUT component dialog box. Users are warned that only single-phase electrical
variables can be interfaced with TACS input nodes, this way. In case of 3-phase modeling, a
splitter object is also required, and the coupling to circuit object must be connected at the single-
phase side of the splitter as shown in Fig. 4.68.
Selection Object name Icon ATP card Description
Coupling
to Circuit
EMTP_OUT
TACS
type 90-93
Value from the electrical circuit into TACS.
90 - Node voltage
91 - Switch current
92 - internal variable special EMTP comp.
93 - Switch status.
Fig. 4.68 - Coupling a 3-phase electrical node to TACS.
Reference Manual
ATPDraw for Windows version 3.5 121
4.9.10.2 TACS sources
The Sources of TACS menu contains the following items:
Selection Object name
Icon
ATP card Description
DC - 11
DC_01
TACS
type 11
TACS step signal source.
AC - 14
AC_02
TACS
type 14
TACS AC cosine signal source.
Pulse - 23
PULSE_03
TACS
type 23
TACS pulse train signal.
Ramp - 24
RAMP_04
TACS
type 24
TACS saw-tooth train signal.
4.9.10.3 TACS transfer functions
All the older TACS transfer functions of previous ATPDraw versions are supported in version 3,
but some of them has been removed from the component selection menu and replaced by a more
general component: the General transfer function. This object defines a transfer function in the s
domain and it can be specified with or without limits. Four more simple transfer functions are also
supported: Integral, Derivative, first order High and Low pass filters.
Selection Object name Icon ATP card Description
General
TRANSF
TACS
General transfer function in s domain.
Order 0-7. Named dynamic limits.
Integral
INTEGRAL
TACS Integral of the input multiplied by K.
Derivative
DERIV
TACS Simple derivative transfer function.
Low pass
LO_PASS
TACS First order low pass filter.
High pass
HI_PASS
TACS First order high pass filter.
4.9.10.4 TACS devices
The following TACS Devices are supported in ATPDraw:
Reference Manual
122 ATPDraw for Windows version 3.5
Selection Object name Icon ATP card Description
Freq sensor - 50
DEVICE50
TACS type
88,98 or 99
Frequency sensor.
Relay switch - 51
DEVICE51
TACS type
88,98 or 99
Relay-operated switch.
Level switch - 52
DEVICE52
TACS type
88,98 or 99
Level-triggered switch.
Trans delay - 53
DEVICE53
TACS type
88,98 or 99
Transport delay.
Pulse delay - 54
DEVICE54
TACS type
88,98 or 99
Pulse delay.
User def nonlin - 56
DEVICE56
TACS type
88,98 or 99
Point-by-point non-linearity.
Multi switch - 57
DEVICE57
TACS Multiple open/close switch.
Cont integ - 58
DEVICE58
TACS type
88,98 or 99
Controlled integrator.
Simple deriv - 59
DEVICE59
TACS type
88,98 or 99
Simple derivative.
Input IF - 60
DEVICE60
TACS type
88,98 or 99
Input-IF component.
Signal select - 61
DEVICE61
TACS type
88,98 or 99
Signal selector.
Sample_track - 62
DEVICE62
TACS type
88,98 or 99
Sample and track.
Inst min/max - 63
DEVICE63
TACS type
88,98 or 99
Instantaneous
minimum/maximum.
Min/max track - 64
DEVICE64
TACS type
88,98 or 99
Minimum/maximum tracking.
Acc count - 65
DEVICE65
TACS type
88,98 or 99
Accumulator and counter.
Rms meter - 66
DEVICE66
TACS type
88,98 or 99
RMS value of the sum of input
signals.
4.9.10.5 Initial conditions
The initial condition of a TACS variable can be specified by selecting TACS object (type 77)
under the TACS | Initial cond. menu. The name of this component is INIT_T and its icon is .
4.9.10.6 Fortran statements
The component dialog box of the Fortran statements | General object provides a Type field where
the user is allowed to specify the type of the object (input, output, inside) and an OUT field for the
single line Fortran-like expression. These statements are written into the /TACS subsection of the
ATP input file starting at column 12.
Reference Manual
ATPDraw for Windows version 3.5 123
The Fortran statements | Math and Logic sub-menus include additional simple objects for the
basic mathematical and logical operations.
General
Selection Object name Icon ATP card Description
General
FORTRAN1
TACS type
88,98 or 99
User specified FORTRAN
expression.
Fortran statements / Math
Selection Object name Icon ATP card Description
x - y
DIFF2
TACS
type 98
Subtraction of two input signals.
x + y
SUM2
TACS
type 98
Addition of two input signals.
x * K
MULTK
TACS
type 98
Multiplication by a factor of K.
x * y
MULT2
TACS
type 98
Multiplication of x by y.
x / y
DIV2
TACS
type 98
Ratio between two input signals.
sqrt (x)
SQRT
TACS
type 98
Square root of the input signal.
| x |
ABS
TACS
type 98
Absolute value of the input signal.
- x
NEG
TACS
type 98
Change the sign of the input
signal.
Fortran statements / Logic
Selection Object name Icon ATP card Description
NOT
NOT
TACS
type 98
Logical operator.
OUT = NOT IN.
AND
AND
TACS
type 98
Logical operator.
OUT = IN_1 AND IN_2.
OR
OR
TACS
type 98
Logical operator.
OUT = IN_1 OR IN_2.
NAND
NAND
TACS
type 98
Logical operator.
OUT = IN_1 NAND IN_2.
NOR
NOR
TACS
type 98
Logical operator.
OUT = IN_1 NOR IN_2.
>
GT
TACS
type 98
Logical operator.
Output = 1 if x > y, 0 otherwise.
>=
GE
TACS
type 98
Logical operator.
Output = 1 if x >= y, 0 otherwise.
Reference Manual
124 ATPDraw for Windows version 3.5
4.9.10.7 Draw relation
When you select TACS | Draw relation, the mouse cursor will change to a pointing hand and the
program is waiting for a left mouse click on a circuit node to set the starting point of a new
relation. You can then draw multiple relations until you click the right mouse button or press the
Esc key. Relations are used to visualize information flow into Fortran statements. These objects
are drawn as blue connections, but have no influence on the component connectivity. You can
work with relations exactly the same way as with connections: relations can be selected, rotated,
deleted, or moved to another position.
4.9.11 User Specified
Selecting the Library item will draw the predefined user specified object LIB.
This object has no input data and cannot be connected with other objects because
it has no input or output nodes.
Fig. 4.69 - Supported user specified objects.
Library
Using this object will result in a $Include statement in the ATP-file. The User specified
field at the bottom of the component dialog box specifies the name of the file (and path if
$Prefix misc. request is unselected under ATP | Settings / Format) that is included by ATP
at run time. The user must keep track of internal node names in this file, and if an internal node is
connected with other nodes of the circuit, the two node must be given the same name.
Ref. 1-ph
Selecting Ref. 1-ph will draw the object LIBREF_1. This object has zero parameters and
two nodes. Reference objects are not represented in the ATP input data file, but serve only
as visualization of connectivity.
Ref. 3-ph
Selecting Ref. 3-ph will draw the object LIBREF_3. This object has zero parameters and
two nodes. Reference objects are not represented in the ATP input data file, but serve only
as visualization of connectivity.
Files...
Besides the standard components, the user is allowed to create User Specified components. The
usage of this feature requires knowledge about ATP's DATA BASE MODULARIZATION technique.
The procedure that is described in the Advanced part of this Manual consists of two steps:
1. Creating a new support file (.sup) using the Objects | User Specified / New sup-file menu.
2. Creating a Data Base Module file (.LIB), which describes the object.
Selecting Files... in the component selection menu executes the Open Component dialog and the
existing support files in the \USP directory are listed. If you select a .sup file from the list and
click on the Open button, the icon of the object will appear in the middle of the active circuit
window. Henceforth the user specified objects operate similarly than standard objects.
Reference Manual
ATPDraw for Windows version 3.5 125
4.9.12 Frequency comp.
Fig. 4.70 - Supported HFS components.
The Harmonic Frequency Scan (HFS) is one of the options under ATP | Settings / Simulation. The
Frequency comp. menu supports four HFS objects for such a simulation:
Selection Object name Icon ATP card Description
HFS Source
HFS_SOUR
SOURCE
type 14
Harmonic frequency source
Cigre load 1 ph
CIGRE_1
BRANCH
type 0
Single-phase CIGRE load
Cigre load 3 ph
CIGRE_3
BRANCH
type 0
3-phase CIGRE load
Linear RLC
RLC_F
BRANCH
type 0
Linear RLC for HFS studies
Selecting HFS under ATP | Settings / Simulation will run the
ATP data case so many times as specified in the Harmonic
source component dialog box. The frequency of the harmonic
source will for each ATP run be incremented. In the example
shown at left, 5 harmonic components are specified in the F/n
column, and the ATP data case will run 5 times.
Fig. 4.71 - Specification of harmonic source frequencies.
In the first run the source frequency will be 1x50 Hz, the second run 5x50 Hz etc. up to the fifth
run f = 11x50 Hz = 550 Hz. The Freq. value specified by the user under ATP | Settings /
Simulation is used here as base frequency. The source frequency can also be specified directly in
Hz and in such case the first F/n must be greater or equal to the Power Frequency. Specifying the
frequencies F/n like 50, 250, 350, 450, and 550 would be equivalent to what is shown in Fig. 4.71.
4.9.13 Standard Component...
In ATPDraw 3.x the standard component support files are stored in a single file called
ATPDraw.scl. The Standard library dialog is the container of supported circuit objects in
alphabetical order. Any component can be selected from this list, then the object's icon appears in
the circuit window exactly the same way as after other selections in the component selection sub-
menus.
Reference Manual
126 ATPDraw for Windows version 3.5
Support files of the present and even all retired objects
(which once were supported in earlier program
versions, but have been removed from the component
selection menu) are included in the standard library.
An old circuit file may of course contain such an older
object, which are also supported internally in
ATPDraw and the program will produce correct
output.
Fig. 4.72 - Standard component library.
127
5. Advanced Manual . . .
. . . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Advanced Manual
ATPDraw for Windows version 3.5 129
This chapter gives an overview of several new features in ATPDraw: Grouping and $Parameter,
usage of the integrated LINE/CABLE CONSTANTS, BCTRAN and the UNIVERSAL MACHINE support,
and describes how to use MODELS in ATPDraw and how to create new user specified object by
means of ATP's $Include and DATA BASE MODULARIZATION features. You will not be shown how
to create the example circuits, but these project files (Exa_*.adp) are part of the ATPDraw
distribution. To load these example circuits into ATPDraw, use the File | Open command (or
Ctrl + O) and select the file name in the Open Project dialog box.
5.1 Grouping: a new ATPDraw feature for multilevel modeling
The new grouping facility in ATPDraw allows multilevel modeling by replacing a group of
objects with a single icon in unlimited numbers of layers. The grouping structure can be taken as a
multi-layer circuit, where the Edit | Edit Group brings the user one step down in details, while the
Edit | Edit Circuit menu brings one step back. This feature increases the readability of the circuit a
great deal and the feature is especially useful for TACS blocks. The grouping feature is
demonstrated by re-designing the circuit Exa_4.adp in the ATPDraw distribution. This circuit
is an induction machine supplied by a pulse width modulated (PWM) voltage source. The
induction machine is represented by a Universal Machine type 3 with a typical mechanical load.
Fig. 5.1 - An induction machine supplied by a pulse width modulated voltage source.
The process of creating a group is as follows:
Select a group of components (inside the polygon in Fig. 5.1).
Select Edit| Compress in the main menu (or Shift+right mouse click + Compress).
After selecting a group the Edit |Compress command will replace it with a single icon. As shown
in Fig. 5.2 in the Compress dialog box the user can specify the data parameters and the nodes for
the new group-object. The selected data and nodes appear as input to the group and their original
values are automatically transferred.
Advanced Manual
130 ATPDraw for Windows version 3.5
Fig. 5.2 - The new Compress dialog window.
Fig. 5.3 - Name and position of the external nodes of the group.
To the left under Objects all components in the group are listed with their name (support file)
followed by ' / ' and the label specified by the user in the component dialog box, or by an
(alpha)numeric identifier if the label was not specified by the user. When the user clicks on one of
the component's name under Objects, its data and nodes appears under Available: starting with
data/node name and followed by their names and values. The user can select a data parameter here
and click on the >> arrow symbol. The selected data parameter will appear in the field to the right
Added to group:. The name of the selected data parameter is editable by double-clicking on it. The
default data values of the new group object will be equal to the original components' data values.
Under Nodes the available nodes for the selected component are similarly listed. The user can
select the desired nodes and specify the position of the group-object node on the icon border 1-12
as shown in Fig. 5.3. All data and nodes listed in the Added to group: will be an external attribute
of the new group-object.
Selected data and nodes can also be removed from the Added to group: by clicking on the <<
Advanced Manual
ATPDraw for Windows version 3.5 131
arrow button. As all other components, the group object is limited to 36 data and 12 nodes. It is
not possible to edit the node and data attributes after the group has been created. If you need to
change the group attributes, the only way is to extract the group in the main menu Edit | Extract
(or Shift+right click to call the shortcut menu and select Extract) and reselect a new group.
After selecting all the required data and nodes click on OK,
then a new support file will automatically be created as a
temporary file in the /GRP folder. The old components
disappear and the new group object is drawn in the circuit
window as shown in Fig. 5.4. The user is then allowed to
connect this group object to the rest of the circuit.
Fig. 5.4 - On return from the Compress the circuit is redrawn.
Group objects operate like any other objects. You can drag and place the new group in the desired
location. The component dialog of the group can be opened by a right or double mouse click and it
appears as shown in Fig. 5.5. The data and node values are specified as in Fig. 5.2 and Fig. 5.3.
Fig. 5.5 - Opening the new group dialog box.
When changing the data parameter in this window the value will be transferred to the member
components. A change in the node name will be transferred in the same way. In this specific case
the Fortran TACS objects are connected to the single-phase side of a splitter. The name of the 3-
phase node V will be transferred as the names VC, VB and VA (from left to right) to the Fortran
objects' output node. The user must follow this phase sequence in the PWM group object, too.
The Compress process for the mechanical load of the induction machine and the component
dialog of the new group can be seen in Fig. 5.6 and Fig. 5.7, respectively.
Advanced Manual
132 ATPDraw for Windows version 3.5
Fig. 5.6 - Selection of data values and external nodes for the mechanical load group.
Fig. 5.7- Component dialog box of the mechanical load group-object.
To view/edit a group the user must first select it and then click Edit | Edit Group in the main menu
(or Ctrl+G). The group is then extracted on the current circuit window. Actually, the grouping
structure can be taken as a multi-layer circuit, where the Edit Group brings the user one step down
in details, while the Edit Circuit brings him one step back. The group is editable in normal way,
but the user can't delete components with reference nodes or data in the mother group). I.e.
components having been referenced in one of the Added to group: lists cannot be deleted. If the
user attempts to do so, a "Marked objects are referenced by compressed group..." warning
message reminds him that the operation is not allowed. Selecting the main menu Edit | Edit
Circuit (or short key Ctrl+H) will close the group edit window. It is possible with several levels of
groups in the circuit. The maximum number of group levels is 1000.
Advanced Manual
ATPDraw for Windows version 3.5 133
Each group has a name GRPxxxxx as shown in the component dialog box header in Fig. 5.5 and
Fig. 5.7. The number following GRP is incremented for every new group. The files
GRPxxxxx.sup are found in the /GRP sub-directory and are editable as any other component. The
group support files are stored in the project file and are taken as temporary files in ATPDraw. It is
safe thus to delete the group sup-files when the project is stored on disk, but not necessary to
perform this operation manually, because the program will delete all of them when you finish the
ATPDraw session.
To customize the icon, click the Icon Editor speed button
in the lower left corner of the Component dialog box as
shown in Fig. 5.5. The icon editor will appear where the
user is free to modify the icon. Fig. 5.8 shows the
Exa_4.adp circuit after grouping the PWM-source and
the mechanical load and modifying their icons. Such
process is convenient for documentation purposes,
because increases the readability of the circuit.
Fig. 5.8 - The icon of the PWM source and the load group
has been customized.
Fig. 5.9 - Customizing the icon of the PWM source.
5.1.1 Grouping nonlinear objects
Non-linearity now can be external data in a group object. Up to three objects can share the same
external nonlinearity. As an example, this section shows how to create a 3-phase, Type-96
hysteretic inductor. You can draw a circuit as shown to the left of Fig. 5.10. To create a group
mark the 3 single-phase inductor and the splitter then select Edit | Compress. The data CURR,
FLUX and RESID are set as external parameters for all the three inductors. The non-linearity
button under Added to group is checked and the Add nonlinear button is checked, too for all three
inductors.
When you press OK the group object is created. The group dialog box shown in Fig. 5.11 contains
only one entry for CURR, FLUX and RESID, which are used for all phases, although 3 copies of
them are present in the data structure. This results in 13 free data cells available for the nonlinear
characteristic (36-3*3)/2 = 13.5). Only one characteristic is entered in the group's dialog box and it
is later copied back to all the three inductors. If that 13 data points were insufficient to describe
the characteristic as you wish, select the Include characteristic option and specify the
characteristic in a disk file. The name of that file must be entered in the $Include field.
The new 3-phase Type-96 group object can be stored as a project file in a special library location
and later copied into any circuit using the File | Import command.
Advanced Manual
134 ATPDraw for Windows version 3.5
Fig. 5.10 - Creating a 3-phase hysteretic inductor.
Fig. 5.11 - Nonlinear characteristic of the 3-phase Type-96 group
(notice that only one characteristic is specified, that is used for all phases).
You can customize the group icon as shown in Fig. 5.11. The hysteresis loop originates from the
original inductor icon. This is done by executing the next sequence of operations: select the group
object and select Edit | Edit Group, then open the component dialog of one of the inductors and
click on the icon editor speed button in it's lower left corner. Select Edit | Copy in the icon editor,
exit the icon editor and the component dialog. Go back to the group object by pressing Edit | Edit
Circuit. In the same way, open the group objects dialog (Fig. 5.11) and click again on the lower
left Icon editor speed button and select Edit | Paste in the editor.
Advanced Manual
ATPDraw for Windows version 3.5 135
5.2 Support of new ATP features $Parameters and Pocket Calculator
$Parameters is a new feature in ATP that allows the user to assign text variables to data and
declare these variables for the whole data case later. This feature is particularly useful when a data
value is used several times in the circuit. Earlier the user had to open all dialog boxes of the
involved components in such cases. This was time consuming and might lead to errors if the user
forgets to change values of some components. Since version 3.1 of ATPDraw, the user is also free
to assign a 6 (or less) characters text string or variable to most data for standard components
instead of a data value in the component dialog box. This is permitted as long as the parameter
option is set in the support file. When specifying the data variable the user does not have to think
about the number of allowed characters in the ATP-file. ATPDraw will add underscore characters
to fill the maximum number of characters. Values can later be assigned to these variables and this
is written to the ATP input file within a $PARAMETER - BLANK block.
A typical example is shown in Fig. 5.12. This is a single phase rectifying bridge distributed with
ATPDraw as Exa_1.adp. It consists of 4 diodes with snubber circuits. The RC values of these
snubbers are identical for all diodes in the practice and can be specified with text variables RES
and CAP respectively. When the user specifies a variable name for the first time, a message box
appears and the user is requested to confirm the operation before the new entry were added to the
global list of variables. If you try to enter special characters in this field, an error message prevents
this.
Fig. 5.12 - Specifying text variables RES and CAP in the component dialog box for an RLC object
Numerical values can be assigned to variables on the Variables page under main menu
ATP | Setting as shown in Fig. 5.13. Variable names are declared in the left column and you can
specify data values or a text string in free format in the right column on this page. Sorting the
declarations is possible with the arrow buttons. Deleting declarations is also supported.
If variables RES and CAP are declared twice with different precision settings, i.e. $Vintage,1 is
checked in a component dialog box and unchecked in another, it will be declared twice with 3 and
13 underscore characters added in the $Parameter declaration. This process is hidden, however,
but the result is seen in the final ATP-file.
If you change the names in the left side column this will affect the text strings (variables) specified
in the components and you will be requested about what action to take (see Fig. 5.14). Available
actions are: reset the variable to zero or the default value (from the support file), or select
parameter and then decide which variables should replace the no longer defined one.
Advanced Manual
136 ATPDraw for Windows version 3.5
The Number of simulations field is for
POCKET CALCULATOR feature of ATP. When
this is higher than unity the variable KNT can
be used in the right column for the current
simulation number. This allows multiple ATP
simulations where specific data variables can
be a function of the simulation number. The
specified variables RES, CAP and LOAD are
written in the ATP-file followed by
underscore characters to enable maximum
precision. The $PARAMETER cards are
written at the bottom of the ATP-file with
after a /REQUEST card, as shown below.
Fig. 5.13 - Assigning values to the variables.
/REQUEST
$PARAMETER
RES_____________= 33.
RES___= 33.
LOAD__= 20.
CAP_____________= 1.
CAP___= 1.
BLANK $PARAMETER
IMPORTANT! Always use a
period '.' after a number in the
value field.
Fig. 5.14 - Action to take when a parameter no longer defined.
5.3 Using the integrated LCC object for line/cable modeling
The integrated LCC objects in ATPDraw are based on the LINE CONSTANTS, CABLE CONSTANTS
or CABLE PARAMETERS supporting routines of ATP-EMTP. The user must first describe the
geometry of the system and the material constants. ATPDraw then performs an ATP run to
process this data case and converts the output punch-file containing the electrical model of the line
or cable into standard lib-file format. This lib-file will then be included in the final ATP-file via a
$Include call. The idea in ATPDraw is to hide as much as possible of the intermediate ATP
execution and files and let the user work directly with geometrical and material data in the circuit.
Only cases producing an electrical model of the line or cable are supported in ATPDraw.
To use the built-in line/cable module of ATPDraw the user must first select a line/cable
component with the desired number of phases (1..9) under Lines/Cables | LCC item in the
selection menu, as shown in Fig. 5.15. This will display a component in the circuit window that is
Advanced Manual
ATPDraw for Windows version 3.5 137
connected to the circuit as any other component. Clicking on the LCC component with the right
mouse button will bring up a special input dialog box called the Line/cable dialog. This window
contains two sheets; one for the various model specifications and one for the data (geometry and
materials) as shown in Fig. 5.16.
Fig. 5.15 - Selecting a line or cable and connecting the LCC object to the rest of the circuit.
Fig. 5.16 - Line/Cable dialog box: Model specification.
When the required data are specified the user can close the dialog by clicking on OK. This will
store the specified data to disk in a user selectable .alc file (atpdraw line/cable) preferably in the
/LCC directory. The user is also asked if ATP should be executed to produce the required punch-
Advanced Manual
138 ATPDraw for Windows version 3.5
files. If the user answers No on the this question, ATP is not executed, and the user is prompted
again later when creating the final ATP-file under ATP | run ATP or (ATP | Make File As...).
It is very important to ensure a correct ATP installation and setup of the run ATP (F2) command
in ATPDraw. This is done under Tools | Options / Preferences. It is recommended to use batch
files. Three such files are distributed with ATPDraw (runATP_S.bat for the Salford version
(DBOS required), runATP_W.bat and runATP_G.bat for the recommended Watcom or
GNU versions of ATP). If the setup of the ATP command is incorrect, the line and cable models
will not be produced.
The punch-file output is transferred to a DATA BASE MODULE file by ATPDraw after the
successful line parameter calculation, so that the node names are handled correctly. The lib-file
required to build the final ATP-file is given the same name as the .alc file (with extension
.lib) and stored in the same folder. The user can also run ATP at any time by clicking on the
Run ATP button, store the .alc data on a different file (Save As) or import old .alc file data
(Import). Clicking on the View button, displays the cross section of the line/cable as shown in Fig.
5.16. For overhead lines the phase number is displayed (with zero as ground). For cables, the
grounded conductors are drawn with a gray color, while the ungrounded conductors are black. The
phase number is according to the rule of sequence: first comes the cable with the highest number
of conductors and the lowest cable number. The thick horizontal line is the ground surface.
Zooming and copying to the Windows clipboard is supported in metafile formats. The Verify
button of the LCC dialog box helps the user to get an overview of the performance of the model in
the frequency domain. This feature is described separately in sub-section 5.4.
When creating a Noda line/cable model the Armafit program is executed automatically to create
the required lib-file. The Armafit command is specified under Tools | Options / Preferences. The
batch file runAF.bat is distributed with ATPDraw. The Noda line/cable data format does not
allow the full path of the lib-file to be written in the ATP-file. As a result, the .alc file should be
stored in the same directory as the .atp file or the .lib file should be moved to this directory
manually. For all other line/cable models the $Prefix/$Suffix option must be turned off or the lib-
files moved to the /USP folder.
ATPDraw supports all the various electrical models: Bergeron (KCLee and Clarke), PI-
equivalents, JMarti, Noda, and Semlyen. It is straightforward to switch between different models.
Under System type the user can select between Overhead Line and Single Core Cable or Enclosing
Pipe.
In the Line/Cable dialog the user can select between:
System type: Model / Type:
Overhead Line: LINE CONSTANTS
Single Core Cables:
CABLE PARAMETERS or
CABLE CONSTANTS
Enclosing Pipe:
CABLE PARAMETERS or
CABLE CONSTANTS
Bergeron: Constant parameter KCLee or Clark
PI: Nominal PI-equivalent (short lines)
JMarti: Frequency dependent model with constant
transformation matrix
Noda: Frequency dependent model (not supported
in CABLE CONSTANTS)
Semlyen: Frequency dependent simple fitted model
(not supported in CABLE PARAMETERS)
Advanced Manual
ATPDraw for Windows version 3.5 139
The Line/Cable Data dialog of Fig. 5.16 really consists of three pages: Model page, Line Data
page or Cable Data page (although only two of them are visible at a time). The parameter names
used in the LCC dialog boxes are identical with that of in Chapter XXI - LINE CONSTANTS and
Chapter XXIII - CABLE CONSTANTS parts of the ATP Rule Book [3]. The Standard data of the
Model page is common for all line and cable types and has the following parameters:
Rho:The ground resistivity in ohmm of the homogeneous earth
(Carson's theory).
Freq. init: Frequency at which the line parameters will be
calculated (Bergeron and PI) or the lower frequency point
(JMarti, Noda and Semlyen) of parameter fitting.
Length:Length of overhead line in [m]/[km] or [miles].
Fig. 5.17 - Standard data for all line/cable models.
5.3.1 Model and Data page settings for Overhead Lines
For overhead transmission lines the System type settings are as follows. High accuracy
(FCAR=blank) is used in all cases:
Transposed: The overhead line is assumed to be
transposed if the button is checked. Disabled
for PI model type.
Auto bundling: When checked this enables the
automatic bundling feature of LINE CONSTANTS.
Skin effect: If the button is checked skin
effect is assumed (IX=4), if unchecked no skin
effect correction. REACT option is set IX=0.
Metric/English: Switching between the Metric and
English unit systems.
Fig. 5.18 - System type options for overhead lines.
Segmented ground: Segmented ground wires. If button is unchecked then the
ground wires are assumed to be continuously grounded.
Real trans. matrix: If checked the transformation matrix is assumed to be
real. The eigenvectors of the transformation matrix are rotated closer to the
real axis so that their imaginary part is assumed to become negligible.
Recommended for transient simulations. Otherwise a full complex transformation
matrix will be used. Recommended for steady state calculations.
5.3.1.1 Model Type settings
Bergeron: No additional settings are required.
PI: For nominal PI-equivalent (short) lines the following optional settings exist under Data:
Fig. 5.19 - Optional settings for PI line models.
Advanced Manual
140 ATPDraw for Windows version 3.5
Printed output: If selected the shunt capacitance, series impedance/admittance
matrix of the unreduced system, and/or of the equivalent phase conductor
system (after elimination of ground wires and the bundling of conductors),
and/or of the symmetrical components will be calculated.
w[C] print out: Selection between the capacitance matrix and the susceptance
matrix (wC).
JMarti: The JMarti line model is fitted in a frequency range beginning from the standard data
parameter Freq. init up to an upper frequency limit specified by the mandatory parameters number
of Decades and the number of sample points per decade (Points/Dec). The model also requires a
frequency (Freq. matrix) where the transformation matrix is calculated and a steady state
frequency (Freq. SS) for calculation of the steady state condition. Freq. matrix parameter should
be selected according to the dominant frequency component of the transient study. The JMarti
model needs in some cases modification of the default fitting data under the optional Model fitting
data field, that can be made visible by unselecting the Use default fitting check box. For further
details please read in the ATP Rule Book [3].
Fig. 5.20 - Parameter settings for the JMarti line model.
Noda: The Noda line model is fitted in a frequency range beginning from the standard data
parameter Freq. init up to an upper frequency limit specified by the number of Decades with the
resolution of Points/Dec. The model needs a frequency (Freq. veloc.), where the wave velocities
of the natural modes of propagation are calculated. A value higher than the highest frequency of
the frequency scan is usually appropriate. The Noda model needs in some cases modification of
the default fitting data under the optional Model fitting data field, that can be made visible by
unselecting the Use default fitting check box. For further details please read in the ATP Rule Book
[3].
Fig. 5.21 - Parameter settings for the Noda line model.
Semlyen: The Semlyen line model is frequency dependent simple fitted model. Fitting range
begins at the standard data parameter Freq. init and runs up to an upper frequency limit specified
by the parameter number of Decades. The model also requires a frequency (Freq. matrix) where
the transformation matrix is calculated and a steady state frequency (Freq. SS) for calculation of
Advanced Manual
ATPDraw for Windows version 3.5 141
the steady state condition. Freq. matrix parameter should be selected according to the dominant
frequency component of the transient study. The Semlyen model needs in some cases modification
of the default fitting data under the optional Model fitting data field, that can be made visible by
unselecting the Use default fitting check box. For more details please read in the ATP Rule Book.
Fig. 5.22 - Parameter settings for the Semlyen line model.
5.3.1.2 Line Data page settings
The data page contains input fields where the user can specify the geometrical or material data.
For overhead lines, the user can specify the phase number, conductor diameters, bundling,
conductor positions, as shown in Fig. 5.23. The number of conductors is user selectable.
ATPDraw set the grounding automatically or gives warnings if the grounding conditions do not
match the fixed number of phases. You can Delete last row of the table using the gray buttons
below or add a new one by clicking on the Add row command. Rows inside the table can also be
deleted, but it must first be dragged down as last row. To drag a row click on its # identifier in the
first column, hold the button down and drag the selected row to a new location or use the
and
arrows at right.
Fig. 5.23 - Line Data dialog box of a 3-phase line. 4 conductors/phase + 2 ground wires.
Ph.no.:phase number. 0=ground wire (eliminated by matrix reduction).
Rin: Inner radius of the conductor. Only available if Skin effect check box
is selected on the Model page (see in Fig. 5.18). If unselected, the
Rin column is removed and a React column appears, where the user
specifies the AC reactance of the line in ohm/unit length.
Rout: Outer radius (cm or inch) of the conductor.
RESIS: Conductor resistance (ohm/unit length) at DC (with Skin effect checked)
or AC resistance at Freq. init (if no Skin effect selected).
Advanced Manual
142 ATPDraw for Windows version 3.5
Horiz: Horizontal distance (m or foot) from the centre of bundle to a user
selectable reference line.
Vtower:vertical bundle height at tower (m or foot).
Vmid: vertical bundle height at mid-span (m or foot). The average conductor
height calculated from the eq. h= 2/3*Vmid + 1/3*Vtower is used in the
calculations.
If System type / Auto bundling is checked on the Model page (Fig. 5.18):
Separ: Distance between conductors in a bundle (cm or inch)
Alpha: Angular position of one of the conductors in a bundle, measured
counter-clockwise from the horizontal line.
NB: Number of conductors in a bundle.
5.3.2 Model and Data page settings for Single Core Cable systems
Support of CABLE CONSTANTS and CABLE PARAMETERS has been added to the LCC module of
ATPDraw recently and the user can select between the two supporting programs by a single button
switch. This enables a more flexible grounding scheme, support of Semlyen cable model instead
of Noda and the cascade PI section. On the other hand in CABLE CONSTANTS enabled state
ATPDraw does not support additional shunt capacitance and conductance input and Noda model
selection. The CABLE CONSTANTS and CABLE PARAMETERS support in ATPDraw does not extend
to the special overhead line part and the multi-layer ground model. For Class-A type cable systems
which consists of single-core (SC) coaxial cables without enclosing conducting pipe the System
type settings are as follows:
Cables in: Select if the cables are in the air,
on the earth surface or in ground.
Number of cables: Specify the number of cables
in the system.
Cable constants: Selects between Cable Constants
and Cable Parameters option. If checked, the
additional conductance and capacitance option
will be switched off and the Ground options on
the Cable Data page will be activated. The
Semlyen model is supported only with Cable
Constants and the Noda model only with Cable
Parameters.
Fig. 5.24 - System type options for SC cables.
Matrix output: Check this button to enable printout of impedance and
admittance matrix data (R, wL and wC).
Snaking: If checked the cables are assumed to be transposed.
Add G: Check this button to allow conductance between conductors.
Not supported for Cable Constants.
Add C: Check this button to allow additional capacitance between conductors.
Not supported for Cable Constants.
5.3.2.1 Model Type settings for SC cables
Bergeron, JMarti, Noda and Semlyen: The Model/Type and Data settings for these SC cable
models are identical with that of the overhead transmission lines as described in section 5.3.1.1.
Users are warned however, that the frequency dependent models may produce unrealistic results,
due to neglecting the frequency dependency of the transformation matrix, which is acceptable in
overhead line modeling but not for cables.
Advanced Manual
ATPDraw for Windows version 3.5 143
Cascade PI model:
If the Cable Constants option is selected under the
System type field, the PI model supports additional
input parameters to produce cascade PI-equivalents.
The cascade PI model is described in the ATP Rule
Book [3]. The Homogenous type can be used with all
grounding schemes.
Fig. 5.25 - SC cable data for cascade PI output.
5.3.2.2 Cable Data page settings for SC cables
The data page contains input fields where the user can specify the geometrical or material data for
cables. The user can turn on sheath/armour by a single button and allowed to copy information
between the cables. The cable number is selected in the top combo box with a maximum number
specified in Number of cables in the Model page.
For CABLE PARAMETERS (Cable Constants unselected) the Ground options are inactive and
number of grounded conductors is calculated internally in ATPDraw based on the total number of
conductors in the system and the number of initially selected phases. For CABLE CONSTANTS
(Cable Constants check box is On) the user must specify which conductor is grounded by
checking the appropriate Ground buttons. A warning will appear if a mismatch between the
number of phases and the number of ungrounded conductors is found. Grounded conductors are
drawn by gray color under View.
Fig. 5.26 - Cable Data dialog box for a 3-phase SC type cable system.
Advanced Manual
144 ATPDraw for Windows version 3.5
For each of the conductors Core, Sheath and Armor the user can specify the following data:
Rin: Inner radius of conductor [m].
Rout: Outer radius of conductor [m].
Rho: Resistivity of the conductor material.
mu: Relative permeability of the conductor material.
mu(ins): Relative permeability of the insulating material outside the
conductor.
eps(ins):Relative permittivity of the insulating material outside the
conductor.
Total radius: Total radius of the cable (outer insulator) [m].
Sheath/Armour On: Turn on optional Sheath and Armour conductors.
Position: Vertical and horizontal positions relative to ground surface and to
a user selectable reference line for single core cables.
5.3.3 Model and Data page settings for Enclosing Pipe type cables
This selection specifies a cable system consisting of single-core (SC) coaxial cables, enclosed by a
conducting pipe (referred as Class-B type in the ATP Rule Book [3]). The cable system might be
located underground or in the air. The System type settings are identical with that of the Class-A
type cables (see in sub-section 5.3.2). When the button Cable Constants is checked the shunt
conductance and capacitance options are disabled and a new check box Ground controls the
grounding condition of the pipe. Transposition of the cables within the pipe is available via the
Snaking button. Cascade PI options can be specified similarly to SC cables (see Fig. 5.25). For
cables with enclosing pipe, the following Pipe data are required:
Fig. 5.27 - System type and Pipe data settings for an Enclosing Pipe cable.
Depth: Positive distance in meter between pipe center and ground surface.
Rin: Inner radius of the pipe in meter.
Rout: Outer radius of the pipe in meter.
Rins: Outer radius of outer insulation (total radius) in meter.
Rho: Resistivity of the pipe conductor.
Mu: Relative permeability of the pipe conductor.
Eps(in): Rel. permittivity of the inner insulation (between cables and pipe).
Eps(out): Rel. permittivity of the outer insulation (around pipe).
G and C: Additional shunt conductance and shunt capacitance between the pipe
and the cables.
Infinite thickness: Infinit thick pipe. ISYST=0 and (uniform grounding).
The cable Data page input fields for Enclosing Pipe type cable systems are identical with that of
the SC cables (see sub-section 5.3.2.2). The only difference is the meaning of Position:
Position: Relative position to pipe center in polar coordinates
(distance and angle).
Advanced Manual
ATPDraw for Windows version 3.5 145
5.4 Verification of the Line/Cable model performance
The Verify button of the LCC dialog box helps the user to get an overview of the performance of
the model in the frequency domain. This feature of ATPDraw enables the user to compare the
line/cable model with an exact PI-equivalent as a function of frequency, or verify the power
frequency benchmark data for zero/positive short circuit impedances, reactive open circuit line
charging, and mutual zero sequence coupling. The Verify module supports two types of frequency
tests:
1) LINE MODEL FREQUENCY SCAN (LMFS) as documented in the ATP benchmark files
DC51/52.dat. The LMFS feature of ATP compares the punched electrical model with the
exact frequency dependent PI-equivalent as a function of a specified frequency range.
2) POWER FREQUENCY CALCULATION (PFC) of zero and positive short circuit impedances and
open circuit reactive line charging, and mutual zero sequence impedance for multi circuit lines.
In the Verify dialog box as shown in Fig. 5.28 the user can choose between a LINE MODEL
FREQUENCY SCAN (LMFS) or a POWER FREQUENCY CALCULATION (PFC) case. Under Circuit
specification, each phase conductor is listed for which the user should assign a circuit number.
The phase order for overhead lines is from the lowest phase number and up to the one assigned
under Data in the Line/Cable dialog box. For cables, the cable with the highest number of
conductors and the lowest cable number comes first (rule of sequence, ATP Rule Book - Chapter
XXIII). A circuit number zero means that the conductor is grounded during the frequency test. For
the LMFS test the user must specify the frequency range (Min freq and Max Freq) along with the
number of points per decade for the logarithmic space frequencies. For the PFC test, the input
parameters are the power frequency and the voltage level (used to calculate the reactive line
charging). Note! The LMFS feature of ATP does not work for Noda models.
Fig. 5.28 - Frequency range specification for the LMFS run (left) and selecting
the line voltage and system frequency for the PFC run (right).
a) Select LMFS: Clicking on OK will result in the generation of a LMFS data case called
xVerify.dat and execution of ATP based on the settings of the default ATP command
(Tools|Options/Preferences). The sources are specified in include files called xVerifyZ.dat,
xVerifyP.dat, and xVerifyM.dat for the zero, positive and mutual sequence respectively.
The individual circuits are tested simultaneously. The receiving ends are all grounded (over 0.1
mW) and all sending ends (if Circuit number > 0) attached to AC current sources of 1 Amps. The
phase angle of the applied current source for the i
th
conductor is -360(i-1)/n where n is the total
number of conductors belonging to that circuit. Phase angle for the zero sequence tests are zero.
Advanced Manual
146 ATPDraw for Windows version 3.5
The mutual coupling works only for 6-phase lines. For circuit one all phases are supplied with
zero phase angle sources, while the phase conductors of the other circuit at the sending end are
open. The View old case button will skip creation of the LMFS data case and trace the program
directly to the procedure that reads the xVerify.lis file, which contains the input impedances
of the electrical model compared to the exact PI-equivalent as function of frequency under various
conditions. ATPDraw can read this file and interpretation of the results is displayed in the LMFS
results window as shown in Fig. 5.30 for the 4-phase JMarti line-model specified in Fig. 5.29.
Fig. 5.29 - Specification of a 4-phase JMarti line model.
Fig. 5.30 - Verifying a JMarti line model 1 Hz to 1MHz. Model is OK for f > 25 Hz.
Advanced Manual
ATPDraw for Windows version 3.5 147
In Fig. 5.30, the user can select the Mode and the Phase number of which the absolute value of the
input impedance is displayed to the left in a log-log plot. It is also possible to copy the curves to
the windows clipboard in metafile format (Copy wmf). The absolute value of the input impedance
of the model and the exact pi-equivalent can be compared for the following cases:
Zero-sequence: AC currents of 1 A with zero phase angle is applied to all phases simultaneously
while the other end of the line/cable is grounded. The zero-sequence impedance is thus equal to
the voltage on the sending end of each phase.
Positive sequence: AC currents of 1 A with a phase angle of -360*(i-1)/n is applied to all phases,
where i is the current phase number in the specific circuit and n is the total number of phases in
the circuit. (A 6-phase line/circuit will result in phase angles 0, -120, -240, 0, -120, -240 while a 4
phase circuit will result in 0, -90, -180, -270). The user specifies a circuit number for each phase
under Circuit specification of Verify Data dialog. The receiving end is grounded.
Mutual sequence: AC currents of 1 A with zero phase angle is applied to all phases of the first
circuit, while the other circuit is open. The receiving ends of all phases are grounded. Apparently
this works only for 6-phase lines.
b) Select PFC: For the PFC test the user must specify the power frequency and the base voltage
level for scaling of the reactive charging. Clicking on OK will result in the generation of a PFC
data case called xVerifyF.dat and execution of ATP based on the settings of the ATP-
Command (Tools | Options / Preferences). In this case, each circuit is tested individually (all other
phases are left open while a specific circuit is tested). The library file describing the electrical
model of the line/cable is included in a new ATP case an supplied by unity voltage or current
sources in order to calculate the steady state short circuit impedances and open circuit reactive line
charging. The file xVerifyF.lis is read by ATPDraw and the short circuit impedances
together with the open circuit line charging is calculated in the zero-sequence and positive-
sequence mode. The results of the calculations are displayed in Fig. 5.31.
Fig. 5.31 - Results of the PFC run.
If the user clicks on Report the content in the string grids of Fig. 5.31 will be dumped to a user
selectable text file. Further details about the operation of the Verify feature and PFC option can be
found in the Appendix part of the Manual.
Advanced Manual
148 ATPDraw for Windows version 3.5
5.5 Using MODELS simulation language
MODELS is a general-purpose description language supported by a set of simulation tools for the
representation and study of time-variant systems. This chapter of the Manual is to a large extent an
extract of the MODELS IN ATP -Language Manual, February 1996 [4] reference. Please consult
this manual for more detailed information on the MODELS language.
MODELS language focuses on the description of the structure of a model and on the function of
its elements. There is a clear distinction in MODELS between the description of a model, and the
use of a model. Individual models can be developed separately, grouped in one or more libraries
of models, and used in other models as independent building blocks in the construction of a
system. The description of a model is intended to be self-documenting. A system can be described
in MODELS as an arrangement of inter-related sub models, independent from one another in their
internal description and in their simulation (e.g. individual models can have different simulation
time step). Description of each model uses a free-format, keyword-driven syntax of local context,
and does not require fixed formatting in its representation.
The main description features of the MODELS language are the following:
The syntax of MODELS allows the representation of a system according to the system's
functional structure, supporting the explicit description of composition, sequence,
concurrence, selection, repetition, and replication;
The description of a model can also be used as the model's documentation;
The interface of a model with the outside world is clearly specified;
The components of a model can be given meaningful names representative of their function
A system can be partitioned into individual sub models, each with a local name space;
The models and functions used for describing the operation of a system can be constructed
in programming languages other than the MODELS language.
The main simulation features supported by the MODELS language are the following:
Distinction between the description of a model and its use, allowing multiple independent
replications of a model with individual simulation management (time step, dimensions,
initial conditions, etc.);
Hierarchical combination of three initialization methods (default, use-dependent, and built-
in), each contributing to the description of the pre-simulation history of a model by a direct
representation of the pre-simulation value of its inputs and variables as functions of time;
Dynamically-controlled modification of the values of the inputs and variables of a model
during the course of a simulation;
Dynamically-controlled modification of the structure of a model (both topological
composition and algorithmic flow) during the course of a simulation.
The new MODELS object created in this chapter is part of the ATPDraw's example file
Exa_8.adp. This example is taken from ATP's benchmark file DC68.DAT, subcase 7. The data
case is a series compensated 500 kV interconnection. ZnO arresters protect the series capacitors
and the energy dissipation of arresters is continuously monitored by a MODELS object. If certain
power or energy limits are exceeded the series capacitor is bypassed through TACS/MODELS
controlled switches to avoid arrester overheating. The complete model is described in the
Application part of this Manual.
Advanced Manual
ATPDraw for Windows version 3.5 149
ATPDraw supports only a simplified usage of MODELS. In general, ATPDraw takes care of the
interface between MODELS and the electrical circuit (INPUT and OUTPUT of the MODELS
section) and the execution of each model (USE). Creating a new Model in ATPDraw normally
consists of two steps:
3. To create a model file (.mod) containing the actual model description.
4. To load this file into the circuit via the MODELS | Files (sup/mod)... sub-menu of the
component selection menu.
5.5.1 Creating the model file
The actual model file describing the operation of the model must be written outside of ATPDraw
using an ASCII text editor or the built in Model Editor under Objects | Model | New mod-file.
Below the model in DC68.DAT has been modified a bit since it is not allowed to use expressions
in the USE of a model. Instead of calculating the voltage across the arrester in the USE statement,
the two node voltages at each side are sent as input parameters and the difference is calculated
inside the model vcap:=V1-V2.
MODEL FLASH_1
comment ****************************************************************
* *
* Function: set or cancel the gap firing control signal *
* Inputs : voltage and current across ZnO resistor *
* Output : the firing signal to the electrical ZnO component *
* *
************************************************************* endcomment
INPUT V1 -- Voltage on positive side of ZNO [V]
V2 -- Voltage of negative side of ZNO [V]
iczn -- ZNO current [Amps]
DATA Pset -- power setting [Megajoules/msec]
Eset -- energy setting [Megajoules]
fdel -- firing delay [msec]
fdur -- firing duration [msec]
VAR power -- power into ZnO resistor [Watts]
trip -- gap firing control signal [0 or 1]
energy -- energy into ZnO resistor [Joules]
tfire -- time at which the gap was last fired [sec]
vcap -- voltage difference across series caps [Volts]
OUTPUT trip
HISTORY INTEGRAL(power) {DFLT:0}
INIT trip:=0
tfire:=0
ENDINIT
EXEC
------------------------------------------------------------------
vcap:=V1-V2
power:=vcap*iczn
energy:=INTEGRAL(power)
------------------------------------------------------------------
IF trip>0 -- is already firing
AND t-tfire>fdur*1.e-3 -- has exceeded firing duration
THEN
trip:=0 -- cancel the firing signal
tfire:=0 -- null the firing time
ENDIF
------------------------------------------------------------------
IF trip=0 -- is not signaling to fire
AND tfire=0 -- firing condition not yet detected
AND ( power >= Pset * 1.e9 -- power setting exceeded
OR energy >= Eset * 1.e6 ) -- energy setting exceeded
THEN
tfire:=t -- set the firing detection time
ENDIF
------------------------------------------------------------------
IF trip=0 -- is not signaling to fire
Advanced Manual
150 ATPDraw for Windows version 3.5
AND tfire>0 -- firing condition has been detected
AND t-tfire>=fdel*1.e-3 -- firing delay exceeded
THEN
trip:=1 -- set the firing signal
ENDIF
ENDEXEC
ENDMODEL
The model file must be given a name with extension .mod and be stored in the \MOD folder. In this
example the name FLASH_1.MOD has been chosen. The name of the disk file must be equal to
the name of the model given in the first line of the model description.
5.5.2 Creating a new MODELS object
An ATPDraw object consists of a file on disk, which is called support file, with extension .sup.
Each model must have a support file in order to be used in ATPDraw. A support file is standard
for all components in ATPDraw and contains the icon, information on node types and position and
on data parameters. There are two options for creating a model object in ATPDraw:
1. Manual operation: creating a support file manually under Object | Model | New sup-file.
2. Automatic operation: selecting a .mod file directly under MODELS of the component
selection menu and let ATPDraw to create the support file.
5.5.2.1 Manual operation
To create a new a support file manually, enter the Objects menu and select the New sup-file under
Model. This menu item will perform the Edit Object dialog. In the Standard
data field, you specify the size of the model: number of nodes and number
of data as shown in Fig. 5.32.
The FLASH_1.MOD file has four nodes (3 input + 1 output) and four data,
(Pset, Eset, fdel, fdur), so you must enter 4 in both Num. fields. Note! All
MODELS nodes must be single phase one.
Fig. 5.32 - Specify the size of the model.
After you have specified the node and data values go to the tabbed notebook style part of the
dialog box. Select the Data page where you specify the values shown in Fig. 5.33. The Name of
the data must be the same as those used in the DATA declaration part of the .mod file. The
Default value appears initially in the models dialog. The default values are taken from the Use
Model statements in DC68.DAT (you can of
course change these values individually for each
use of the model). Min and Max restrict the
legal input range. No restriction is applied here
to data values, so Min=Max.
Fig. 5.33 - Specify Data parameters.
Param is set to 0, which means that no variable text string can be assigned to the data value. Digit
is the maximum number of digits allowed in the ATP input file. When high precision is checked,
$Vintage, 1 is enabled and Digits is split in two values for high and low precision.
Advanced Manual
ATPDraw for Windows version 3.5 151
After you have specified the data values click on the Nodes tab to enter to the node window as
shown in Fig. 5.34. The Name identifies the node in the Node and Component dialog boxes. The
name you enter here must be the same as those used in the INPUT and OUTPUT declaration
sections of the .mod file. The Position field is
the node position on the icon border as shown at
the right. The Kind value is the input/output type
of the node. Number of Phases (1/3) must be set
to 1 for all Models node because only single-
phase nodes are supported.
Fig. 5.34 - Specifying Node attributes.
Supported Kind values for MODELS objects are:
0: Output node. 3: Switch status input node.
1: Current input node. 4: Machine variable input node.
2: Voltage input node. 5: TACS variable (tacs)
6: Imaginary part of steady-state node voltage (imssv)
7: Imaginary part of steady-state switch current (imssi)
8: Output from other model.
The Kind parameter of model object nodes can be changed
later in the Node dialog box (input field Type), as shown in
Fig. 5.35. This window appears when the user clicks on a
Model node with the right mouse button.
Fig. 5.35 - Model node dialog box.
Note! If a model output is used as input for another model, the model, which produces the output
must be USEd before the use of the model that is supplied with this output. This can be done by
specifying a lower group number for the model with output signals and selecting the Sorting by
group number option under ATP | Settings / Format.
Model objects also have an icon, which represents the
object on the screen and an optional help, which
describes the meaning of parameters. If no user
supplied help text was given, the Help Viewer
displays the model definition file (.mod)
automatically. If you need a help text, this feature can
be overridden by opening the Help Editor with the
button at the right hand side of the dialog box.
The Icon Editor appears similarly, by clicking on the
button. Here you can be creative and draw a
suitable icon for the new model object as shown in
Fig. 5.36. When you finished select the Done menu
item.
Fig. 5.36 - The icon of the new model objects.
Advanced Manual
152 ATPDraw for Windows version 3.5
The Save or Save As buttons can be used to save the new support file to disk. Default location of
Model support files is the \MOD folder. The .sup file does not need to have the same name as
the model file, but it is recommended.
The new model object has now been created is ready for use. You can reload and modify the
support file of the model objects whenever you like. Selecting the Edit sup-file item of the Objects
| Model menu pops-up the well known Edit Object dialog box with the model object controls and
the user is allowed to customize data and node values, icon and help text of the object.
Selecting MODELS | Files (sup/mod)... in the component selection menu performs an Open Model
dialog box where you can choose a model support file. If you select the file FLASH_1.SUP the
icon of the new model appears immediately in the circuit window and it can be connected with
other object in normal way.
The MODEL:FLASH_1 dialog box of the new model object has an additional input section
Models besides the standard DATA and NODES attributes as shown in Fig. 5.37. This new section
has two input fields: Model file for locating the model description file and a Use As field for
specification of the model_name in the USE model AS model_name statement of MODELS.
The input and output interface for MODELS objects, the use of the model and interfacing it with
the rest of the circuit are handled automatically by ATPDraw. The model description is written
directly in the ATP input file. Blank lines are removed when inserting the .mod file. The general
structure of the MODELS section in an .atp input file is shown below:
MODELS
/MODELS
INPUT
IX0001 {v(CR30A )}
IX0002 {v(CR20A )}
IX0003 {i(CRZ2A )}
OUTPUT
GAPA
------------------------------------------
MODEL FLASH_1
...
Description of the model.
Complete copy of the
FLASH_1.MOD is pasted here.
...
ENDMODEL
------------------------------------------
USE FLASH_1 AS FLASH_1
INPUT
V1:= IX0001
V2:= IX0002
iczn:= IX0003
DATA
Pset:= 1.
Eset:= .9.
fdel:= 4.
fdur:= 20.
OUTPUT
GAPA:=trip
ENDUSE
ENDMODELS
Advanced Manual
ATPDraw for Windows version 3.5 153
Fig. 5.37 - Component dialog box of the FLASH_1 model object.
5.5.2.2 Automatic operation
Version 3 of ATPDraw for Windows is capable of reading the .mod file directly, examine its
INPUT, OUTPUT and DATA variables, and suggest a support file on the correct format. Either a
comma or CR+LF is accepted as separator characters between variables by ATPDraw. Comment
flags 'C' in column 1 and '--' are also handled. Maximum 12 input+output variables are allowed
along with 36 data variables. Only single variables are allowed (not indexed).
The automatic sup-file creation procedure can be
activated by selecting the MODELS | Files (sup/mod)...
item of the component selection menu. When reading the
mod-file ATPDraw performs a message box shown in
Fig. 5.38.
Fig. 5.38 - Interpretation of the model file.
You are free to modify the default support file or accept the default icon and node positions, or
Cancel the interpretation procedure. If you click on Yes, the Edit Object dialog box will appear
where you can edit the icon, change node positions, set new default values and Kind (= I/O Type
for current/voltage etc. input). If you select No, the default ATPDraw object is drawn in the circuit
window immediately (Fig. 5.39). Input nodes are positioned on the left side of the icon and the
outputs on the right. In both cases, a support file is automatically created. This file can later be
modified under Objects | Model | Edit sup-file.
Fig. 5.39 - Default model object (FLASH_1.SUP)
Advanced Manual
154 ATPDraw for Windows version 3.5
5.5.3 Recording internal MODELS variables
ATPDraw supports the RECORD feature of MODELS to record any internal variable of a model
object in the .pl4 output. This option is found under the ATP | Settings / Record menu. All
MODELS objects in the active circuit window are listed with their USE AS name in the list box
under Model as shown in Fig. 4.19. When you select a model in this field, variables (declared
under VAR section of the .mod file) are listed under Variable. Each variable has a default alias
name that appears in the Alias field, but it can be modified according to the user need.
To record a variable, click on the Add button.
The alias name can be changed later by selecting
an item in the Record list box and type in a new
name. The record request can be removed by
selecting the item and click on Remove.
This record list is stored in the circuit file, but it
does not follow the circuit when the circuit is
copied to the clipboard or the export group
option is used.
Fig. 5.40 - Record of model variables.
5.6 BCTRAN support in ATPDraw
ATPDraw provides a user-friendly interface for the BCTRAN transformer matrix modeling, to
represent single and three-phase, two and three winding transformers. After the user has entered
the open circuit and short circuit factory test data, the ATPDraw calls ATP and executes a
BCTRAN supporting routine run. Finally, ATPDraw includes the punch-file into the ATP-file. The
windings can be Y, D or Auto coupled with support of all possible phase shifts. The nonlinear
magnetization branch can optionally be added externally.
Fig. 5.41 shows the BCTRAN dialog box, which appears when the user selects BCTRAN under
Transformers of the component selection menu. Under Structure, the user specifies the number of
phases, the number of windings, the type of core (not supported yet, except for single phase cores,
triplex and three-phase shell type), and the test frequency. The dialog box format adapts the
number of windings and phases. The user can also request the inverse L matrix as output by
checking AR output. An Auto-add nonlinearities button appears when an external magnetizing
branch is requested.
Under Ratings the line-voltage, rated power, and type of coupling must be specified. Supported
winding Connections are: A (auto-transformer), Y (wye) and D (delta). The Phase shift menu
adapts these settings with all types of phase shifts supported. If the connection is A or Y, the rated
voltage is automatically divided by 3 to get the winding voltage VRAT.
Under Factory test, the user can choose either the Open circuit test or the Short circuit test.
Advanced Manual
ATPDraw for Windows version 3.5 155
Fig. 5.41 - The BCTRAN dialog box.
Under the Open circuit tab the user can specify where the factory test has been performed and
where to connect the excitation branch. In case of a three winding transformer one can choose
between the HV, LV, and the TV winding. Normally the lowest voltage is preferred, but stability
problems for delta-connected nonlinear inductances could require the lowest Y-connected winding
to be used. Up to 6 points on the magnetizing curve can be specified. The excitation voltage and
current must be specified in % and the losses in kW. With reference to the ATP Rule Book, the
values at 100 % voltage is used directly as IEXPOS=Curr [%] and LEXPOS=Loss [kW]. One
exception is if External Lm is chosen under Positive core magnetization. In this case only the
resistive current is specified resulting in IEXPOS=Loss/(10 SPOS), where SPOS is the Power
[MVA] value specified under Ratings of the winding where the test has been performed. If zero-
sequence open circuit test data are also available, the user can similarly specify them to the right.
The values for other voltages than 100 % can be used to define a nonlinear magnetizing
inductance/resistance. This is set under Positive core magnetization:
a) Specifying Linear internal will result in a linear core representation based on the 100 %
voltage values.
b) Specifying External Lm//Rm the magnetizing branch will be omitted in the BCTRAN
calculation and the program assumes that the user will add these components as external
objects to the model.
Advanced Manual
156 ATPDraw for Windows version 3.5
c) Specifying External Lm will result in calculation of a nonlinear magnetizing inductance first as
an I
rms
-U
rms
characteristic, then automatically transformed to a current-fluxlinked characteristic
(by means of an internal SATURA-like routine). The current in the magnetizing inductance is
calculated as
] [ / ) 3 / ] [ ( ) 3 / ] [ [%] 10 ( ] [
2 2
kV V kW Loss MVA SPOS Curr A I
ref rms
- =
where V
ref
is actual rated voltage specified under Ratings, divided by 3 for Y- and Auto-
connected transformers.
The user can choose to Auto-add nonlinearities under Structure and in this case the magnetizing
inductance is automatically added to the final ATP-file as a Type-98 inductance. ATPDraw
connects the inductances in Y or D dependent on the selected connection for actual winding for a
3-phase transformer. In this case, the user has no control on the initial state of the inductor(s). If
more control is needed (for instance to calculate the fluxlinked or set initial conditions) Auto-add
nonlinearities should not be checked. The user is free to create separate nonlinear inductances,
however. The Copy+ button at the bottom of the dialog box allows the user to copy the calculated
nonlinear characteristic to an external nonlinearity. What to copy is selected under View/Copy. To
copy the fluxlinked-current characteristic used in Type-93 and Type-98 inductances Lm-flux
should be selected.
The Short circuit data can be specified as shown in Fig.
5.42. With reference to the ATP Rule Book; Imp [%] is
equal to ZPOS, Pow. [MVA] is equal to SPOS, and Loss
[kW] is equal to P. These three values are specified for
all the windings. If zero-sequence short circuit factory
test data are also available, the user can similarly specify
them to the right of the positive sequence values after
selecting the Zero sequence data available check box.
Fig. 5.42 - Short circuit factory test data.
If Auto-transformer is selected for the primary and secondary winding (HV-LV) the impedances
must be re-calculated according to Eq. 6.45, 6.46, 6.50 of the EMTP Theory Book [5]. This task is
performed by ATPDraw and the values
*
L H
Z
-
,
*
T L
Z
-
, and
*
T H
Z
-
are written to the BCTRAN-file
automatically.
( )
L H
L
T L
L H
H
T H
L H
L H
L H T H T L T L
L H
H
L H L H
V V
V
z
V V
V
z
V V
V V
z z z z
V V
V
z z
-
-
-
+
-
= =
-
=
- - - - - - - - 2
* *
2
*
, ,
where Z
L-H
, Z
L-T
, and Z
H-T
are the short-circuit impedances Imp. [%] referenced to a common
Pow.[MVA] base.
When the user clicks on OK the data structure is stored in a binary disk file with extension .bct
and stored in the /BCT folder. This BCT-file is stored in the ATPDraw project file just like LCC-
files for lines/cables. Then the user is offered to generate a BCTRAN-file and run ATP. This is
really optional, since often a new BCTRAN-file will be required anyway during the final ATP-file
generation. Trying to run ATP is a good practice however, since this will quickly warn the user
about possible problems. The button Run ATP requests an ATP execution without leaving the
dialog box. If the BCTRAN-file is correct, a punch-file will be created. This file is directly
included in the final ATP-file and there is no conversion to a library file as for lines/cables. This
Advanced Manual
ATPDraw for Windows version 3.5 157
means in practice that a new BCTRAN-file will be created and ATP executed automatically (when
creating the final ATP-file) each times the transformers node names change.
There is also an Import button available to import existing BCT-files. The user can also store the
BCT-file with a different name (Save As), which is useful when copying BCTRAN-objects. The
View+ and Copy+ buttons are for the nonlinear characteristic. Copy+ transfers the selected
characteristic to the Windows clipboard in text format with 16 characters fixed columns (the first
column is the current). View+ displays the nonlinear characteristic in a standard View Nonlin
window. The Help button at the lower right corner of the dialog box displays the help file
associated with the BCTRAN object. This help text briefly describes the meaning of input data
values.
1. Excitation test data
Specified under Factory test/Open circuit.
The data required by BCTRAN are:
FREQ = Test frequency under Structure
IEXPOS = Curr for the 100% voltage value in Open circuit, Positive sequence.
= Loss for the 100% voltage value divided by 10*SPOS when External Lm
requested.
SPOS = Power under Ratings for winding specified under Performed at.
LEXPOS = Loss for the 100% voltage value in Open circuit, Positive sequence.
IEXZERO= Curr for the 100% voltage value in Open circuit, Zero sequence.
SZERO = Power under Ratings for winding specified under Performed at.
LEXZERO= Loss for the 100% voltage value in Open circuit, Zero sequence.
The above input values can be derived from the factory test data as shown next:
IEXPOS= Iex*V*100/SPOS for single phase,
IEXPOS= Iex*3*V*100/SPOS for 3-phase
where Iex [kA] = excitation current,
V [kV] = excitation voltage.
SPOS[MVA]= power base
IEXZERO= 0 for single phase
IEXZERO= 1/3*Iexh*3*V*100/SZERO for 3-phase
where Iexh [kA]= zero-sequence excitation current,
SPOS[MVA]= power base (normally equal to SPOS)
Y-connected windings (typical values):
3-leg core type: IEXZERO= IEXPOS
5-leg core type: IEXZERO= 4*IEXPOS
2. Winding cards
Specified under Ratings. The data required by BCTRAN are:
VRAT = L-L voltage [kV] for D-connection or single phase transformers
L-L voltage [kV] divided by 3 for A (Auto) and Y connections.
3-phase only.
BUS1- = The present node names of the transformer component in ATPDraw
BUS6 taking the connection and Phase shift [deg] into account.
Renaming the nodes will require a new BCTRAN execution performed
automatically upon ATP|Run ATP or Make File.
3. Short circuit test data
Specified under Factory test / Short circuit. The data required by BCTRAN are:
Pij = Loss (kW) under Short circuit, Positive sequence
ZPOSij = Imp (%) under Short circuit, Positive sequence
SPOS = Pow (MVA) under Short circuit, Positive sequence
ZZEROij= Imp (%) under Short circuit, Zero sequence
SZERO = Pow (MVA) under Short circuit, Zero sequence
Advanced Manual
158 ATPDraw for Windows version 3.5
The short circuit input data can be derived from the factory test reports, as shown next:
ZPOSij= Usi/Isi*SPOS/Vri^2*100 for single phase,
ZPOSij= Ush/3*Ish)*SPOS/(Vri
2
)*100 for 3-phase
where
Usi [kV] = short-circuit voltage at winding i
Isi [kA] = nominal current at winding i
SPOS[MVA]= power base
Vri [kV] = rated line voltage at winding i
ZZEROij= 0 for single phase
ZZEROij= Ush/Ish*SZERO/(Vri
2
)*300 for 3-phase
where
SZERO[MVA]= power base
Zero-sequence tests must be performed with open Delta-windings.
The BCTRAN component is found under Transformers | BCTRAN in the component selection
menu and it can be edited and connected to the main circuit as any other component.
The default icon is shown left. The nodes appear automatically dependent on the selected
connection and number of windings.
The data specified in Fig. 5.41 will result in an icon at left with 3 three-phase
terminals and one single-phase neutral point common to the primary and secondary
autotransformer windings. The label shows the transformer connection.
5.7 Non-standard component dialog boxes
The component dialog box in which the user is allowed to change the object's attributes shows a
considerable similarity nearly for all components: on the Attributes page the components data can
be specified, on the optional Characteristic page you specify the input characteristic of non-linear
components, while the node names in the top-right table is just for your information.
The following components deviate somewhat from the above description:
General 3-phase transformer (GENTRAFO)
Universal machine (UM_1, UM_3, UM_4, UM_6, UM_8)
Statistical / Systematic switch (SW_STAT, SW_SYST)
Harmonic source (HFS_SOUR)
5.7.1 Saturable 3-phase transformer
The component dialog box of this transformer model is shown in Fig. 5.43. This dialog box also
has an Attributes and a Characteristic page, but the former is largely differs from the standard
layout. The function of the Group No, Label, Comment and Output fields are the same as on any
other component dialog boxes, the meaning of the other fields are given next. The pair I
o
, F
o
defines the magnetizing branch inductance at steady state. R
m
is the resistance of the magnetizing
branch representing the hysteresis and eddy current losses of the iron core. I
o
, F
o
, R
m
may be left
blank if the magnetizing branch is neglected in the simulation. Checking the 3-leg core turns the
transformer into a TRANSFORMER THREE PHASE type with high homopolar reluctance that
can be specified in the appearing R
0
-field. With the button 3-leg core unchecked, the model is a
saturable transformer with low homopolar reluctance (e.g. a 3-phase transformer with at least one
delta winding).
Advanced Manual
ATPDraw for Windows version 3.5 159
Checking the RMS button enables specification of the saturation characteristic in rms values for
current and voltage on the Characteristic page. A conversion to flux-current values is performed
internally in ATPDraw. If the button is unchecked, normal flux-current values should be entered.
The tertiary winding can be turned on or off by checking the 3-wind. button. The nominal voltage
of the transformer windings (!) must be given in [kV]. The short circuit inductances may be
specified in [mH] if Xopt. parameter is 0 (default) on the ATP | Settings / Simulation page.
Otherwise, the impedance is given in [W] at frequency Xopt.
Fig. 5.43 - General saturable transformer dialog.
Four types of winding couplings are supported by this general transformer object: Wye, Delta lead,
Delta lag, and Y180. Icons to the right of the short circuit impedances visualize the selected
coupling. The letters A, B, and C are the phase terminals, while the Roman numbers I, II, and III
denotes the leg number. The table below shows how to represent typical 2-winding transformers:
Yd1: Y (primary) + Dlag (secondary)
Yd5: Y180 (primary) + Dlead (secondary)
Yd7: Y180 (primary) + Dlag (secondary)
Yd11: Y (primary) + Dlead (secondary)
Yy0: Y (primary) + Y (secondary)
Dy1: Dlead (primary) + Y (secondary)
Dy5: Dlag (primary) + Y180 (secondary)
Dy7: Dlead (primary) + Y180 (secondary)
Dy11: Dlag (primary) + Y (secondary)
Yy6: Y (primary) + Y180 (secondary)
* Y/zig-zag, D/zig-zag trafos are out of scope at present.
The data specified in Fig. 5.43 will result in an icon at left with 3 three-phase
terminals and 2 single phase nodes: one for the primary neutral and one for
connection of the magnetization circuit with external saturation (optional).
The Saturable 3-phase object is found under Transformers in the component selection menu and
it can be edited and connected to the main circuit as any other components.
Advanced Manual
160 ATPDraw for Windows version 3.5
The Help button at the lower right corner of the dialog box displays the help file associated with
the GENTRAFO object. This help text briefly describes the meaning of input data values:
Data: Io= Current [A] through magnetizing branch (MB) at steady state.
Fo= Flux [Wb-turn] in MB at steady state.
The pair Io, Fo defines the inductance in MB at steady state.
Rm= Resistance in magnetizing branch in [ohm]. 5-leg core or 3-leg
shell.
R0= Reluctance of zero-sequence air-return path for flux. 3-leg
core-type
Rp= Resistance in primary winding in [ohm].
Lp= Inductance in primary winding in [mH] if Xopt.=0
Inductance in primary winding in [ohm] if Xopt.=power freq.
Vrp= Rated voltage in [kV] primary winding.
Rs= Resistance in secondary winding in [ohm].
Ls= Inductance in secondary winding in [mH] if Xopt.=0
Inductance in secondary winding in [ohm] if Xopt.=power freq.
Vrs= Rated voltage in [kV] secodary winding.
Rt= Resistance in tertiary winding in [ohm].
Lt= Inductance in tertiary winding in [mH] if Xopt.=0
Inductance in tertiary winding in [ohm] if Xopt.=power freq.
Vrt= Rated voltage in [kV] tertiary winding.
RMS= unchecked: Current/Flux characteristic must be entered.
checked: Irms/Urms characteristic must be entered.
ATPDRAW performs a SATURATION calculation.
3-leg core = checked: 3-leg core type transformer assumed.
TRANSFORMER THREE PHASE
unchecked: 5-leg or 3-leg shell type assumed. TRANSFORMER.
3-wind.= turn on tertiary winding.
Points: It's possible to enter 9 points on the current/flux characteristic.
The required menu is performed immedeately after the input menu.
The points should be entered as increasingly larger values.
The point (0,0) is not permitted (added internally in ATP).
5.7.2 Universal machines
Handling of electrical machines in version 3 of ATPDraw has been updated substantially to
provide a user-friendly interface for most of the electrical machine modeling options in ATP.
Supported Universal Machine (UM) types are:
Synchronous machine (UM type 1)
Induction machines (UM type 3 & 4)
DC machine (UM type 8)
Single-phase machine (UM type 6)
The component dialog box of the Universal Machine object is substantially differs to the standard
dialog box layout, as shown in Fig. 5.44. In the UM component dialog box the user enters the
machine data in five pages: General, Magnet, Stator, Rotor, Init. Several UM models are allowed
with global specification of initialization method and interface. These Global options can be
specified under ATP | Setting / Switch/UM.
On the General page data like stator coupling and the number of d and q axis coils are specified.
On the Magnet. page the flux/inductance data with saturation are specified, while on the Stator
and Rotor pages the coil data are given. Init page is for the initial condition settings.
Advanced Manual
ATPDraw for Windows version 3.5 161
Fig. 5.44 - Universal machine input dialog.
The dialog boxes for all the universal machines are similar. The type 4 induction machine does not
have the Rotor coils group, since this is locked to 3. None of the type 3 and 4 induction machine
have the field node of course.
The single-phase machine (type 6) and the DC machine (type 8) do not have the Stator coupling
group. For the type 6 machine the number of d-axis is locked to 1. Even if the number of rotor
coils or excitation coils can be set to maximum 3, only the first d-axis coils will have external
terminals for a type 1, 6, and 8 machine. The other coils will be short circuited. Rotor coils are
short circuited in case of type 3 machine, while the type 4 machine has an external terminal for all
its 3 coils.
Fig. 5.45 shows the various pages for universal machine data input. The buttons under the
Saturation on the Magnet. page turns on/off the various saturation parameters for the d- and q-
axis. This is equivalent to the parameter JSATD and JSATQ in the ATP data format. Selecting
symm is equal to having JSATD=5 and JSATQ=0 (total saturation option for uniform air gap).
On the Stator page, you specify the Park transformed quantities for resistance and inductance for
the armature winding. The number of coils on the Rotor page and on the Init page for manual
initialization adapts the specification of the number of rotor coils. First the d-axis coils are listed
then comes the q-axis coils.
The function of the Group No, Label, Comment fields are the same as on any other component
dialog boxes. The Help button at the lower right corner of the dialog box displays the help file
associated with the UM objects.
Advanced Manual
162 ATPDraw for Windows version 3.5
Fig. 5.45 - Data pages of the universal machines dialog box.
The Help text briefly describes the meaning of input data values and node names as the example
shows next for UM type 1 (Synchronous machine):
Data:
General page:
Pole pairs - Number of pole pairs
Tolerance - Rotor-speed iteration-convergence margin.
Frequency - Override steady state frequency.
Stator coupling
Select between Y, Dlead (AC, BA, CB) and Dlag (AB, BC, CA)
Selecting Y turns neutral node Neut on.
Rotor coils
Specify the number of d- and q- axis rotor coils. Maximum total
number is 3. Only terminals for 1st d-axis coil. The other coils
are assumed short circuited.
Global
Visualization of mode of initialization and interface.
Set under the main menu ATP|Settings/Switch/UM for each circuit.
Stator page:
Specify resistance and inductance in Park transformed
quantities (d- q- and 0- system). All inductances in H or pu.
Rotor page:
The total number of coils are listed and given data on the Rotor
page. First the d-axis coils then the q-axis coils are listed.
Specify resistance and inductance for each coil. All the coils
except the first is short circuited. All inductances in H or pu.
Advanced Manual
ATPDraw for Windows version 3.5 163
Magnet. page:
LMUD - d-axis magnetization inductance.
LMUQ - q-axis magnetization inductance.
Turn on/off the saturation.
Symm. is equal saturation in both axis, specified only in d.
LMSD - d-axis saturated inductance.
FLXSD - d-axis flux-linkage at the saturation knee point.
FLXRD - d-axis residual flux-linkage (at zero current).
LMSQ - d-axis saturated inductance.
FLXSQ - q-axis flux-linkage at the saturation knee point.
FLXRQ - q-axis residual flux-linkage (at zero current).
NB! All inductances in H or pu.
Initial page:
Initial conditions dependent on manual or automatic
initialization is chosen under ATP|Settings/Switch/UM
Automatic:
AMPLUM - initial stator coil (phase) voltage [V].
ANGLUM - angle of phase A stator voltage [deg].
Manual:
Specify stator current in the d- q- and 0-system
Specify rotor current inn all coils
OMEGM - initial mechanical speed [mech rad/sec or unit]
THETAM - initial pos of the rotor [elec rad]
Output:
TQOUT=1: air gap torque
=2: 1 + d-axis common flux
=3: 2 + d-axis magnetization current
OMOUT=1: rotor shaft speed in [rad/sec]
=2: 1 + q-axis common flux
=3: 2 + q-axis magnetization current
THOUT=checked: rotor position in [mech rad]
CURR =checked: all physical coil currents
Node:
Stator - 3-phase armature output terminal.
M_NODE - air-gap tourque node.
FieldA - Pos. terminal of exitation rotor coil.
(the other coils are grounded)
FieldB - Neg. terminal of exitation rotor coil.
BUSM - torque-source node for automatic initialization.
BUSF - field-source node for automatic initialization.
Neut - Neutral point of Y-coupled stator coils.
The final section of the Help file describes the equivalent electrical network of the mechanical
network for torque representation:
Shaft mass (moment of inertia) Capacitance (1kg/m2 1 Farad)
Shaft section (spring constant) Inverse inductance. (1 Nm/rad 1/Henry)
Shaft friction (viscous damping) Conductance. (1 Nm/rad/s 1/ohm)
Angular speed Voltage (1 rad/s 1 Volt)
Torque Current (1 Nm 1 Amp)
Angle Charge (1 rad 1 Coulomb)
L1
__ __ ____ ___oooo_______________
| | | | | | | | |
|J1| K1 |J2| --> T _|_ < _|_ < |
==| |=====| |==== ====> ___C1 >R1 ___C2 >R2 O I
| | | | | < | < |
|__| |__| | | | | |
D1 D2
C1=J1, C2=J2, R1=1/D1, R2=1/D2, L1=1/K1, I=T
Advanced Manual
164 ATPDraw for Windows version 3.5
5.7.3 Statistic/systematic switch
Handling of statistic/systematic switches in version 3 of ATPDraw has been made more general
by introducing the independent/master/slave concept. The component dialog boxes of the
statistical switches slightly differs however from the standard switch dialog box layout as shown
in Fig. 5.46.
The user can select the Switch type in a combo box out of the supported options: Independent,
Master or Slave. This will also enable the possible input fields and change the number of nodes
(note that slave switch has 4 nodes). The Distribution for the statistical switch takes into account
the specification of the IDIST parameter on the miscellaneous switch card (ATP | Settings /
Switch/UM). Selecting IDIST=1 will disable the Distribution group and force Uniform
distribution. The Open/Close radio buttons select if the switch closes or opens with Ie as current
margin for opening switches. The number of ATP simulations is set by the miscellaneous switch
parameter Num. on the ATP | Settings / Switch/UM page. This value influences the 1
st
misc. data
parameter NENERG of ATP. ATPDraw sets the correct sign of NENERG: i.e. > 0 for statistic or
< 0 for systematic switch studies. The function of the Group No, Label, Comment and Output
fields are the same as for any other standard components.
Fig. 5.46 - Dialog box of the statistic switch (top) and data windows of the systematic switch.
Advanced Manual
ATPDraw for Windows version 3.5 165
The Help button at the lower right corner of the dialog box displays the help file associated with
the object. This text briefly describes the meaning of input data values and node names as shown
below:
SW_STAT - Statistic switch.
Distribution: Select uniform or gaussian distribution.
If IDIST=1 under ATP|Settings/Switch/UM only uniform is possible.
Open/Close: Select if the switch closes or opens.
Current margin available for opening switch.
T = Average switch opening or closing time in [sec.]
For Slave switches this is the average delay.
Dev.= Standard deviation in [sec.].
For Slave switches this is the deviation of the delay.
Ie = Switch opens at a time T>Tmean and the current through
the switch is less than Ie.
Switch type:
INDEPENDENT: Two nodes
MASTER : Two nodes. 'TARGET' punched. Only one is allowed.
SLAVE : Four nodes. Specify node names of MASTER switch.
The icon and nodes of the objects adapt the switch type setting.
Node: SW_F= Start node of switch.
SW_T= End node of switch.
REF_F= Start node of the MASTER switch
REF_T= End node of the MASTER switch
SW_SYST - Systematic switch.
Tbeg = When ITEST=1 (ATP|Settings/Switch/UM)
Tmid = When ITEST=0 (ATP|Settings/Switch/UM)
Tdelay= For SLAVE switches. If ITEST=0 : T=Tmid.
INCT = Size of time increment in [sec.].
NSTEP = Number of time increments.
Switch type:
INDEPENDENT: Two nodes
MASTER : Two nodes. 'TARGET' punched.
SLAVE : Four nodes. Specify node names of MASTER switch.
The icon and nodes of the objects adapt the switch type setting.
Node : SW_F = Start node of switch.
SW_T = End node of switch.
REF_F = Start node of the MASTER switch
REF_T = End node of the MASTER switch
5.7.4 Harmonic source
The component dialog box of the Harmonic source that is used in HFS studies deviates somewhat
from the standard source dialog box layout as shown in Fig. 4.71.
Selecting HFS under ATP | Settings / Simulation the ATP will
run the case so many times as specified in the Harmonic source
component dialog box. The frequency of the harmonic source
will for each ATP run be incremented. The user selects the
source type by the Voltage or Current radio button. In the
example shown here, the data case will run 5 times because the
F/n column has 5 harmonics entered.
Fig. 5.47 - Harmonic source dialog box.
The base frequency here is the Freq. value specified under ATP | Settings / Simulation. The
amplitude and angle of the F/n' th harmonic source is given in columns Ampl. and Angl.
Advanced Manual
166 ATPDraw for Windows version 3.5
5.8 Creating new circuit objects in ATPDraw
The user specified objects (USP) are either customized standard objects or objects created for the
use of $INCLUDE and DATA BASE MODULARIZATION feature of ATP-EMTP. The Objects | User
Specified | New sup-file menu enables the user to create a new support file for such a user
specified object or customize data/node properties and the icon or the help text of an existing one.
The number of nodes and data specified in the Edit Object dialog box for USP objects must be in
line with the ARG and NUM declarations in the header section of the Data Base Module (DBM)
file. The number of data must be in the range of 0 to 36, and the number of nodes in the range of 0
to 12. The USP support files are normally located in the /USP folder.
Two new circuit objects will be created in this section: a 6-pulse controlled thyristor-rectifier
bridge that is used as building block for simulating a 12-pulse HVDC station (Exa_6.adp) in
section 6.4 of the Application Manual, and a generator step-up transformer model with winding
capacitances and hysteretic core magnetism included. The latter object is used in a transformer
inrush current study (Exa_11.adp) in section 6.8.2 of the Application Manual.
5.8.1 Creating a 6-phase rectifier bridge
The Data Base Module (DBM) file shown next describes a 6-pulse thyristor rectifier bridge (based
on exercise 54 in [2]). The process of creating a DBM-file is certainly the most difficult part of
adding new circuit objects to ATPDraw. The input file to the DBM supporting routine of ATP
begins with a header declaration followed by the circuit description. The ATP Rule Book [3]
chapter XIX-F explains in detail how to create such a file. The output punch-file of the DBM
supporting routine can actually be considered as an external library file which is included to the
ATP simulation at run time via a $INCLUDE call.
BEGIN NEW DATA CASE --NOSORT--
DATA BASE MODULE
$ERASE
ARG,U____,POS___,NEG___,REFPOS,REFNEG,ANGLE_,Rsnub_,Csnub_
NUM,ANGLE_,Rsnub_,Csnub_
DUM,PULS1_,PULS2_,PULS3_,PULS4_,PULS5_,PULS6_,MID1__,MID2__,MID3__
DUM,GATE1_,GATE2_,GATE3_,GATE4_,GATE5_,GATE6_,VAC___,RAMP1_,COMP1_
DUM,DCMP1_,DLY60D
/TACS
11DLY60D .002777778
90REFPOS
90REFNEG
98VAC___ =REFPOS-REFNEG
98RAMP1_58+UNITY 120.00 0.0 1.0VAC___
98COMP1_ =(RAMP1_-ANGLE_/180) .AND. UNITY
98DCMP1_54+COMP1_ 5.0E-3
98PULS1_ = .NOT. DCMP1_ .AND. COMP1_
98PULS2_54+PULS1_ DLY60D
98PULS3_54+PULS2_ DLY60D
98PULS4_54+PULS3_ DLY60D
98PULS5_54+PULS4_ DLY60D
98PULS6_54+PULS5_ DLY60D
98GATE1_ = PULS1_ .OR. PULS2_
98GATE2_ = PULS2_ .OR. PULS3_
98GATE3_ = PULS3_ .OR. PULS4_
98GATE4_ = PULS4_ .OR. PULS5_
98GATE5_ = PULS5_ .OR. PULS6_
98GATE6_ = PULS6_ .OR. PULS1_
/BRANCH
$VINTAGE,0
POS___U____A Rsnub_ Csnub_
POS___U____BPOS___U____A
Advanced Manual
ATPDraw for Windows version 3.5 167
POS___U____CPOS___U____A
U____ANEG___POS___U____A
U____BNEG___POS___U____A
U____CNEG___POS___U____A
/SWITCH
11U____APOS___ GATE1_
11U____BPOS___ GATE3_
11U____CPOS___ GATE5_
11NEG___U____A GATE4_
11NEG___U____B GATE6_
11NEG___U____C GATE2_
BEGIN NEW DATA CASE
C <= "C" in the 1
st
column is mandatory here!
$PUNCH
BEGIN NEW DATA CASE
BLANK
The header section of the DBM-file starts with an ARG declaration after the special ATP request
card DATA BASE MODULE. It's function is to specify the external variables (numerical + node
names) and the sequence of arguments for the $INCLUDE procedure. The NUM card tells what
arguments are numerical. DUM card lists the dummy or local variables, which are typically internal
node names. ATP gives dummy nodes a unique name and thus let you use the same DBM-file
several times in a data case avoiding node name conflicts. The rest of the DBM-file describes the
rectifier bridge in a normal ATP data structure, except that sorting cards /TACS, /BRANCH,
/SWITCH etc., are used in a special way. Sorting cards are required, but no BLANK TACS,
BLANK BRANCH, etc. indicators are needed.
The 3-phase thyristor bridge has a 3-phase AC input node and two single phase DC output nodes.
The firing angle is taken as input data and the snubber parameters are also practical to consider as
numerical input to the model. The model created here accepts external reference signals for the
zero crossing detector (alternatively the DBM module file could have detected its own AC input),
thus the new USP object will have 5 nodes and 3 data:
U____ : The AC 3-phase node
POS___: The positive DC node
NEG___: The negative DC node
REFPOS: Positive reference node.
REFNEG: Negative reference node.
ANGLE_: The firing angle of the thyristors.
Rsnub_: The resistance in the snubber circuits.
Csnub_: The capacitance in the snubber circuits.
Note the importance of the number of characters used for each parameter. The U____ parameter
has only 5 characters, because it is a 3-phase node and the extensions A, B and C are added inside
the DBM-file. Underscore characters _ has been used to force the variables to occupy the 6
characters space for node names and 6 columns ($VINTAGE, 0) for the snubber data. Running
the DBM-file through ATP will produce a .pch punch file shown below:
KARD 3 4 5 6 6 6 7 7 8 8 8 9 9 10 10 10 11 11 11 12 12 12 13 13 13
14 14 14 15 15 15 16 16 16 17 17 17 18 18 18 19 19 19 20 20 20 21 21 21 24
24 24 24 25 25 25 25 26 26 26 26 27 27 27 27 28 28 28 28 29 29 29 29 31 31
31 32 32 32 33 33 33 34 34 34 35 35 35 36 36 36
KARG-20 4 5 4 5-16-16-17 6-17-18-18-19 -1-18-19 -1 -2-20 -2 -3-20 -3 -4-20
-4 -5-20 -5 -6-20 -1 -2-10 -2 -3-11 -3 -4-12 -4 -5-13 -5 -6-14 -1 -6-15 1
2 7 8 1 1 2 2 1 1 2 2 1 1 2 3 1 1 2 3 1 1 2 3 1 2
-10 1 2-12 1 2-14 1 3-13 1 3-15 1 3-11
KBEG 3 3 3 12 19 3 69 3 20 13 3 12 3 3 32 19 12 3 69 12 3 69 12 3 69
Advanced Manual
168 ATPDraw for Windows version 3.5
12 3 69 12 3 69 13 25 3 13 25 3 13 25 3 13 25 3 13 25 3 25 13 3 9
3 27 39 9 21 3 15 9 21 3 15 3 21 15 9 3 21 15 9 3 21 15 9 3 9
65 3 9 65 3 9 65 9 3 65 9 3 65 9 3 65
KEND 8 8 8 17 24 8 74 8 25 18 8 17 8 8 37 24 17 8 74 17 8 74 17 8 74
17 8 74 17 8 74 18 30 8 18 30 8 18 30 8 18 30 8 18 30 8 30 18 8 13
8 32 44 13 25 8 20 13 25 8 20 7 25 20 14 7 25 20 14 7 25 20 14 7 14
70 7 14 70 7 14 70 13 8 70 13 8 70 13 8 70
KTEX 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
$ERASE
/TACS
11DLY60D .002777778
90REFPOS
90REFNEG
98VAC___ =REFPOS-REFNEG
98RAMP1_58+UNITY 120.00 0.0 1.0VAC___
98COMP1_ =(RAMP1_-ANGLE_/180) .AND. UNITY
98DCMP1_54+COMP1_ 5.0E-3
98PULS1_ = .NOT. DCMP1_ .AND. COMP1_
98PULS2_54+PULS1_ DLY60D
98PULS3_54+PULS2_ DLY60D
98PULS4_54+PULS3_ DLY60D
98PULS5_54+PULS4_ DLY60D
98PULS6_54+PULS5_ DLY60D
98GATE1_ = PULS1_ .OR. PULS2_
98GATE2_ = PULS2_ .OR. PULS3_
98GATE3_ = PULS3_ .OR. PULS4_
98GATE4_ = PULS4_ .OR. PULS5_
98GATE5_ = PULS5_ .OR. PULS6_
98GATE6_ = PULS6_ .OR. PULS1_
/BRANCH
$VINTAGE,0
POS___U____A Rsnub_ Csnub_
POS___U____BPOS___U____A
POS___U____CPOS___U____A
U____ANEG___POS___U____A
U____BNEG___POS___U____A
U____CNEG___POS___U____A
/SWITCH
11U____APOS___ GATE1_
11U____BPOS___ GATE3_
11U____CPOS___ GATE5_
11NEG___U____A GATE4_
11NEG___U____B GATE6_
11NEG___U____C GATE2_
$EOF User-supplied header cards follow. 31-May-02 15.46.06
ARG,U____,POS___,NEG___,REFPOS,REFNEG,ANGLE_,Rsnub_,Csnub_
NUM,ANGLE_,Rsnub_,Csnub_
DUM,PULS1_,PULS2_,PULS3_,PULS4_,PULS5_,PULS6_,MID1__,MID2__,MID3__
DUM,GATE1_,GATE2_,GATE3_,GATE4_,GATE5_,GATE6_,VAC___,RAMP1_,COMP1_
DUM,DCMP1_,DLY60D
This file is very similar to the DBM input file, but with a different header and with the original
DBM-file header given at the bottom instead. This file is ready to $INCLUDE into an ATP input
file by ATPDraw. The file must be given a name and extension .LIB and stored in the default
\USP directory. The name HVDC_6.LIB is used here as an example.
When the punch-file from the DBM-file has been created, the next step is to create a support file
for the new HVDC_6 object in the the Objects | User Specified menu. The process of creating a
new object consists of two steps: create parameter support and create the icon.
Advanced Manual
ATPDraw for Windows version 3.5 169
First select the New sup-file in the popup menu. A notebook-style dialog box shown in Fig. 5.48
appears where you specify the number of data and nodes. The number of arguments on the NUM
card(s) of the DBM-file tells you the Number of data, which is 3 in this example. The number of
arguments on the ARG card(s) minus number of arguments on the NUM card(s) specifies the total
Number of nodes, which is 5 in this example.
On the Data tab, you specify the names of the data parameters, number of digits (it must be less or
equal the space used in the DBM-file, which is 6 in this case) a default value, and the Min/Max
values. The name of data need not be equal to the names used in the DBM punch-file, but the
sequence of data must be the same as on the ARG and NUM card(s). After specifying data
properties, click on the Node tab and set the node control parameters as shown in Fig. 5.48. The
Name of nodes, the number of Phases (1/3) and the node position on the icon border (1-12) are to
be given here. Codes for the available node positions are shown in the icon at right. Kind is not
used here. It must be left unity (default) for all nodes. The name of the nodes need not be identical
with the names used in the DBM-file, but the node sequence must be the same as on the ARG card.
Fig. 5.48 - Properties of the new HVDC_6 object.
ATPDraw writes all three names of a 3-phase node in the $INCLUDE statement. In this example
only the core name of the 3-phase node is expected on the argument list, because the phase
identifiers A-B-C are added internally in the DBM-file. This option requires the Internal phase
seq. checked box be selected in the component dialog box of the HVDC_6 object, as shown in
Fig. 5.51. If it is selected, ATPDraw writes only the 5-character long core names in the
$INCLUDE statement and let the extensions A, B and C be added inside the DBM library file.
Note that ATPDraw does not perform any diagnosis of the include file before sending the node
names. Moreover, the Internal phase seq. option may result in conflict with transposition objects.
As a result, this option should in general not be used in transposed circuits. To avoid the conflict
use three input names for 3-phase nodes in DATA BASE MODULE files.
Each user specified objects might have a unique icon, which represents the object on the screen
and an optional on-line help, which describes the meaning of parameters. These properties can be
edited using the built in Help and Icon Editors. Fig. 5.49 shows an example file that is associated
with the user specified 6-phase rectifier bridge.
Data
Node
Advanced Manual
170 ATPDraw for Windows version 3.5
Fig. 5.49 - Help file of the HVDC_6 object.
Fig. 5.50 shows the icon editor window. The red lines in the background indicate the possible
node positions on the icon border. Connecting lines to the external nodes of the object should be
drawn from the symbol in the middle and out to the node positions specified in Fig. 5.48. The
completed icon of the 6-pulse rectifier bridge is shown in Fig. 5.50.
Fig. 5.50 - The icon associated with the new HVDC_6 object.
Finally, the just created support file must be saved to disk using the Save or Save As buttons. User
specified sup-files are normally located in the \USP folder and their default extension is .sup.
You can reload the support file of any user specified objects whenever you like, using the User
Specified | Edit sup-file option of the Objects menu.
The User Specified | Files in the component selection menu provides access to the user specified
objects. The component dialog box of the HVDC_6 object is very similar to that of the standard
objects, as shown in Fig. 5.51. The name of the DBM-file which is referenced in the final ATP
input file must be specified in the $Include field under User specified. The Send parameters check
box is normally selected, if the USP object has at least one input node or data.
Advanced Manual
ATPDraw for Windows version 3.5 171
Fig. 5.51 - Component dialog box of the new user specified HVDC_6 object.
5.8.2 Creating a user specified, nonlinear transformer model
Supporting routine BCTRAN can be used to derive a linear representation of a single or 3-phase
multi-winding transformer, using excitation and short circuit test data. If the frequency range of
interest does not exceed some kHz, the inter-winding capacitances and earth capacitance of the
HV and LV windings can be simulated by adding lumped capacitances connected to the terminals
of the transformer. Although BCTRAN produces only a linear representation of the transformer,
connecting nonlinear inductances to the winding closest to the iron core as external elements,
provides an easy way to take the saturation and/or hysteresis into account. It is noted that the
BCTRAN object is now supported by ATPDraw in a user friendly way (see in section 5.6), but the
procedure described here gives more flexibility in handling of the iron core nonlinearities and
allows incorporation of winding capacitances in the USP object, if needed. Further advantage of
the USP based modeling is that users do not need to run the BCTRAN supporting routine as many
times as such kind of transformers present in the circuit before the execution of the time domain
simulation. Creating such a user specified component however requires some experience in two
ATP supporting routines: DATA BASE MODULE and BCTRAN.
The BCTRAN model requires easily available input data only, like the name-plate data of a
generator step-up transformer shown below:
Voltage rating V
high
/V
low
132/15 kV
Winding connection: Ynd11
Power rating: 155 MVA
Excitation losses: 74 kW
Excitation current: 0.3% / 2.67 A
Short circuit losses: 461 kW
Short circuit reactance: 14 %
Advanced Manual
172 ATPDraw for Windows version 3.5
The zero sequence excitation current and losses are approximately equal to the positive sequence
measurements because the presence of delta connected secondary winding. Taking that the
nonlinear magnetizing inductance is going to be added to the model as an external element, only
the resistive component of the excitation current (0.05%) must entered in the BCTRAN input file
shown next:
BEGIN NEW DATA CASE
ACCESS MODULE BCTRAN
$ERASE
2 50. 0.05 155. 74. 0.05 155. 74. 0 2 2
1 76.21 HVBUSASTRPNTHVBUSBSTRPNTHVBUSCSTRPNT
2 15.0 LVBUSALVBUSCLVBUSBLVBUSALVBUSCLVBUSB
1 2 461. 14.0 155. 14.0 155. 0 1
BLANK
$PUNCH
BLANK
BEGIN NEW DATA CASE
BLANK
BLANK
Running this file through ATP will produce an output punch-file that can be used as input for the
Data Base Module (DBM) run. The process of creating a DBM-file is certainly the most difficult
part of adding new circuit objects to ATPDraw. The input file to the DBM supporting routine of
ATP begins with a header declaration followed by the circuit description. The ATP Rule Book [3]
chapter XIX-F explains in detail how to create such a file. The output of the DBM supporting
routine is a .lib file, that can actually be considered as an external procedure which is included to
the ATP simulation at run time via a $INCLUDE call.
5.8.2.1 Creating a Data Base Module file for the BCTRAN object
The DBM-file begins with a header declaration followed by the ATP request card DATA BASE
MODULE and ends with a $PUNCH request. The ARG declaration together with the NUM card (if
needed) specifies the external variables (numerical + node names) and the sequence of arguments
for the $INCLUDE procedure. The rest of the file describes the BCTRAN model. Note that data
sorting card /BRANCH is part of the file, but no BLANK BRANCH indicator is required.
The ARG declaration of the DBM-file includes 7 node names in this example:
HVBUSA, HVBUSB, HVBUSC: The 3-phase node of the high voltage terminal
LVBUSA, LVBUSB, LVBUSC: The 3-phase node of the low voltage terminal
STRPNT: The 1-phase node of the HV neutral
The rest of the DBM-file is the transformer model description as produced by the BCTRAN
supporting routine of ATP. The structure of the DBM input file is shown below:
BEGIN NEW DATA CASE --NOSORT--
DATA BASE MODULE
$ERASE
ARG,HVBUSA,HVBUSB,HVBUSC,LVBUSA,LVBUSB,LVBUSC,STRPNT
<<<< The .PCH file generated by the >>>>
<<<< BCTRAN supporting routine must >>>>
<<<< be inserted here >>>>
BEGIN NEW DATA CASE
C !!! This comment line here is mandatory !!!
$PUNCH, MYTRAFO.LIB
BEGIN NEW DATA CASE
BLANK
BLANK
Advanced Manual
ATPDraw for Windows version 3.5 173
Running the DBM-file through ATP will produce a file mytrafo.lib that must be stored in the
\USP folder of ATPDraw.
KARD 3 3 4 4 6 6 10 10 11 11 13 13 16 16 20 20 25 25
KARG 4 6 4 5 5 6 1 7 4 6 2 7 4 5 3 7 5 6
KBEG 3 9 9 3 9 3 3 9 3 9 3 9 9 3 3 9 9 3
KEND 8 14 14 8 14 8 8 14 8 14 8 14 14 8 8 14 14 8
KTEX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
$ERASE
C <++++++> Cards punched by support routine on 28-Jan-02 14.10.13 <++++++>
C ACCESS MODULE BCTRAN
C $ERASE
C 2 50. 0.05 155. 74. 0.05 155. 74. 0 2 2
C 1 76.21 HVBUSASTRPNTHVBUSBSTRPNTHVBUSCSTRPNT
C 2 15.0 LVBUSALVBUSCLVBUSBLVBUSALVBUSCLVBUSB
C 1 2 461. 14.0 155. 14.0 155. 0 1
C BLANK
$VINTAGE, 1,
1LVBUSALVBUSC 9121.6157726436
2LVBUSBLVBUSA 0.0
9121.6157726436
3LVBUSCLVBUSB 0.0
0.0
9121.6157726436
USE AR
1HVBUSASTRPNT 19.966704093183 .16716783247242
2LVBUSALVBUSC -101.4441679294 0.0
515.41471986794 .00647606659729
3HVBUSBSTRPNT 0.0 0.0
0.0 0.0
19.966704093183 .16716783247242
4LVBUSBLVBUSA 0.0 0.0
0.0 0.0
-101.4441679294 0.0
515.41471986794 .00647606659729
5HVBUSCSTRPNT 0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
19.966704093183 .16716783247242
6LVBUSCLVBUSB 0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
-101.4441679294 0.0
515.41471986794 .00647606659729
$VINTAGE, 0,
$UNITS, -1.,-1.
USE RL
C ----------------- << case separator >>> -----------
$EOF User-supplied header cards follow. 28-Jan-02 14.28.28
ARG,HVBUSA,HVBUSB,HVBUSC,LVBUSA,LVBUSB,LVBUSC,STRPNT
5.8.2.2 Creating new support file and icon
Next step is to create a new user specified object via the Object | User Specified | New sup file
menu of ATPDraw. The process of creating a new object consists of two steps: creating parameter
support and creating an icon. Since no NUM card exists in the DBM header the number of data is 0,
the number of nodes is 3 in this example as shown in Fig. 5.52.
On the Nodes tab, a Name can be assigned to each nodes. The number of phases and the node
position on the icon border must also be specified here. The name of the nodes may differ from
the name used in the .lib file, but the node sequence must be the same as specified on the ARG list.
Each user specified component might have an icon and an optional on-line help, which describes
the meaning of input parameters. The appearance of this icon is up to the users' creativity, but it is
Advanced Manual
174 ATPDraw for Windows version 3.5
recommended to indicate three phase nodes with thick lines and to locate them according to the
Pos (1..12) setting on the Nodes tab. Finally, the support file of the object must be saved to disk
using the Save button (the default location is the /USP folder), to make the new USP object
accessible via the User Specified | Files option of the component selection menu.
Fig. 5.52 Creating support file for the new BCTRAN object.
The user specified components can be used in combination with the new grouping feature of
ATPDraw as shown in Fig. 5.53. In this example, the linear part of the transformer model has
been completed with winding capacitances as external components and three nonlinear Type-96
hysteretic inductors in delta connection at the 15 kV terminals, which represent the nonlinear
magnetic core.
The Compress feature of ATPDraw supports single icon replacement of these 7 objects. The inter-
winding and winding-to-earth capacitances are input parameters to the group object. As shown
below, the group object's icon can be customized, as well. An artistic icon may improve the
readability of the circuit and help in understanding of the circuit file for others.
Fig. 5.53- Compressing the transformer model into a single object.
Data
Node
175
6. Application Manual . . .
. . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Application Manual
ATPDraw for Windows version 3.5 177
This chapter begins with some simple examples. You will not be shown how to create these
circuits, but the circuits files Exa_*.adp are part of the ATPDraw distribution. To load these
example circuits into the circuit window of ATPDraw, use the File | Open command (or Ctrl + O)
and select the file name in the Open Project dialog. The resulting ATP-files will be given at the
end of each description. Simulation results and/or comparison with measurements are also
presented in some cases. These figures have been obtained by processing the .pl4 output file or
field test records with prost-processors PlotXY or ATP_Analyzer.
6.1 Switching in 500 kV system (Exa_3.adp)
This example shows how to perform a switching analysis in a simplified network. The line model
used in this example is a P-equivalent line calculated for 5000 Hz, by LINE CONSTANTS outside of
ATPDraw. How to create a more accurate JMarti line model and how to use LCC objects, the
interactive graphical preprocessor of ATPDraw for LINE/CABLE CONSTANTS/PARAMETERS
support, are shown in section 5.3 of the Advanced Manual and section 6.5 of this manual.
The example circuit is shown on Fig. 6.1/a, the equivalent ATPDraw circuit in Fig. 6.1/b.
Fig. 6.1/a - Switching example circuit.
Fig. 6.1/b - Example circuit 3, Line switching(Exa_3.adp).
Source:
The source is a 500 kV 3-phase AC source. The amplitude of the voltage source (U/I = 0) is
kV
3
2
500 = Amp . The input menu for the source is shown in Fig. 6.2:
Line switch:
The P-equivalent line is connected to the source with a three-phase switch, having independent
closing and opening times in all phases. The switches are initially open and close at:
Phase A: 33.33 ms, Phase B: 36.10 ms, Phase C: 38.80 ms
Application Manual
178 ATPDraw for Windows version 3.5
Fig. 6.2 - Three phase source input window.
Capacitor bank:
The capacitor bank is 2.51 mF in all phases. The switches connecting the bank to the network is
initially open and close at
Phase A: 133.33 ms, Phase B: 136.10 ms, Phase C: 138.80 ms
Pi-equivalent line:
The P-equivalent line R-L-C data were calculated by the LINE CONSTANTS supporting routine of
ATP outside ATPDraw. The line is a 500 kV overhead line with 2x3 phase conductors and 2
ground wires. Line parameters were taken from ATP benchmark file DCN3.DAT. The calculation
resulted in the following line matrices for that 138 miles line (only lower-triangle part is given).
Read the inductances in [mH], the resistances in [W] and the capacitances in [mF]:
R L C
474.76 288.8 2.3224
353.81 315.13 71.35 266.15 -0.3637 2.3684
442.02 353.81 474.76 73.45 71.35 288.8 -0.2725 -0.3637 2.3224
If you click the right mouse button on the line P icon of Fig. 6.1/b, the object dialog box shown in
Fig. 6.3 appears, where you can enter the above R-L-C matrix data. The imaginary part of the line
impedance may be specified in [W], as well. In that case the Xopt. parameter under ATP | Settings
/ Simulation must be set equal to the frequency, at which the impedances were calculated (e.g.
Xopt. should be set 5 kHz in this example).
Application Manual
ATPDraw for Windows version 3.5 179
Fig. 6.3 - Three phase pi-equivalent input window
The ATP input file created by ATPDraw and the simulated voltages at the 500 kV bus, at the
sending and at the receiving end of the line are shown below:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW June, Sunday 30, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
C dT >< Tmax >< Xopt >< Copt >
1.E-5 .2
500 5 1 1 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
1 BEGA ENDA 474.76 288.82.3224
2 BEGB ENDB 353.81 71.35-0.364315.13266.152.3684
3 BEGC ENDC 442.02 73.45-0.273353.81 71.35-0.364474.76 288.82.3224
51X0003ABUSA .55 8.98
52X0003BBUSB .711 11.857
53X0003CBUSC
X0003ABUSA 200. 0
X0003BBUSB 200. 0
X0003CBUSC 200. 0
X0010A 2.51 0
X0010B 2.51 0
X0010C 2.51 0
BEGA 1.E7 0
BEGB 1.E7 0
BEGC 1.E7 0
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
BUSA BEGA .03333 10. 0
BUSB BEGB .0361 10. 0
BUSC BEGC .0388 10. 0
X0010ABUSA .13333 10. 0
X0010BBUSB .1361 10. 0
X0010CBUSC .1388 10. 0
/SOURCE
Application Manual
180 ATPDraw for Windows version 3.5
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14X0003A 0 408248. 60. -1. 1.
14X0003B 0 408248. 60. -120. -1. 1.
14X0003C 0 408248. 60. 120. -1. 1.
/INITIAL
/OUTPUT
BEGA BEGB BEGC ENDA ENDB ENDC BUSA BUSB BUSC
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
6.2 TACS controlled induction machine (Exa_4.adp)
This example shows the usage of the Universal Machine type 3, manual initialization along with
usage of TACS. The use of info arrows, whose purpose is to visualize information flow between
the TACS FORTRAN objects are also shown here. The info arrows can be selected under TACS |
Draw relation in the component selection menu and they are handled graphically as normal
connections. They do not affect the ATP-file, however. The example is taken from exercise 46 in
[2]. The ATPDraw constructed circuit is shown in Fig. 6.4/b:
Fig. 6.4/a - Induction machine + TACS
Application Manual
ATPDraw for Windows version 3.5 181
Fig. 6.4/b - ATPDraw scheme of the induction machine example (Exa_4.adp)
The TACS part of the circuit controls three sources producing a pulse width modulated armature
voltage. The TACS objects FORTRAN1 is referenced in the Reference part of this Manual.
The input window of the TACS object at the end of the TACS chain is shown in Fig. 6.5. This
TACS object creates the armature voltage in phase A of the 3-phase node V.
Fig. 6.5 - TACS Fortran input window
In the TACS statement the user must type in the expression(s). Only single phase TACS Fortran
objects are supported. The two (blue) info arrows into this TACS object serve as visualization of
the SIGA (from node SIGA) and VD signals.
Application Manual
182 ATPDraw for Windows version 3.5
The induction machine was given the data shown in Fig. 6.6:
Fig. 6.6 - Induction machine input window
The numerical values in Fig. 6.6 must be specified by the user as in the case for all object input
windows. The identity text in front of each attribute strictly follows the input variable in the ATP
Rule Book [3]. The ATP-file created by ATPDraw is shown below:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Tuesday 30, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
C Induction motor supplied by a
C pulse width modulated source.
C Test example 1.
C dT >< Tmax >< Xopt >< Copt >
1.E-5 .1
500 3 0 0 1 0 0 1 0
TACS HYBRID
/TACS
98FS =1000
23PULS 2. .001 .0005 .000252
98AMPL =4.0*FS
98SQPUL =AMPL*(UNITY-PULS)
98VDELTA =SQPUL*DELTAT
98VTRI 65 +VDELTA
14VCONTC .95 60. -90.
14VCONTB .95 60. -210.
14VCONTA .95 60. 30.
98VB =(2.0*SIGB-1.0)*VD/2.0
98VC =(2.0*SIGC-1.0)*VD/2.0
98SIGC =VCONTC .GT. VTRI
98VA =(2.0*SIGA-1.0)*VD/2.0
98SIGB =VCONTB .GT. VTRI
98SIGA =VCONTA .GT. VTRI
98VD =791.2
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
Application Manual
ATPDraw for Windows version 3.5 183
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
NEUT 1.E6 2
BUSMG 13.33 1
BUSMG 5.E6 3
BUSMG BUSMS 1.E-6 1
BUSA VA .001 1
BUSB VB .001 1
BUSC VC .001 1
BUSA NEUT 1.E4 0
BUSB NEUT 1.E4 0
BUSC NEUT 1.E4 0
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14BUSMS -1-374.03889 1.E-5
60VC 0
60VB 0
60VA 0
C Next comes Universal Machines
19 UM
00 0
BLANK general UM specification
3 1 1331BUSMG 2 .1885 60.
C Magnetization inductances
182.840692 .0160
.785398163 .0160
C Stator coils
BUSA NEUT 1 73.5587
.095 .0005BUSB NEUT 1 80.545
.095 .0005BUSC NEUT 1 -154.1034
C Rotor coils
.075 .0004 1 169.6725
.075 .0004 1 19.285
BLANK UM
/INITIAL
2BUSMG 182.840692
3BUSMG 182.840692
/OUTPUT
VA VB VC
BLANK TACS
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
The new Grouping feature of ATPDraw can be used in a creative way in this example, too. The
pulse width modulated source and the mechanical load might be compressed into a single icon.
The compressed version of this example circuit is also part of the ATPDraw distribution with the
name of Exa_4g.adp.
As shown left an artistic icon may improve the readability of the circuit
and help in understanding the circuit for non-author users.
Fig. 6.7 - PWM source and mechanical load compressed
into a single icon.
Application Manual
184 ATPDraw for Windows version 3.5
6.3 Usage of the Library and Reference objects (Exa_5.adp)
This example shows how can ATPDraw be used efficiently by a professional ATP user. The ATP
expert simply creates the required ATP-file for a power system (which is often already available)
outside of ATPDraw, and then builds a simple ATPDraw case, where the power system is
included with $Include and a limited number of additional components e.g. switches are added.
Node names internally in the include file must be the same as those used in the ATPDraw data
case (F1 - F4, left adjusted in this example!).
The data case can then be sent to a person whose knowledge about ATP is rather limited. This
person can run the case, manipulate the switches and establish the ground fault current along a
transmission line, e.g. for relay setting purposes.
Any user specified objects might be used as a simple $Include library (Send parameters button
off), but a predefined object is available under the User Specified field in the selection menu. Two
other special objects are also available: the Ref.1-ph and Ref.3-ph. These objects are not
written in the ATP-file at all, and their purpose is only to visualize a connectivity in the $Include
file.
An example, where these objects (Library (LIB1.A-B) and 3-phase reference (LIBREF_3))
have been used, is shown in Fig. 6.8.
Fig. 6.8 - Usage of a library reference objects (Exa_5.adp)
If you click with the right mouse button on the Library object, (identified by the LIB1.A-B label)
you get the input window to set the element attributes, as shown in Fig. 6.9.
Fig. 6.9 - Library input window.
The most important menu field in this window is the $Include which gives the name and path of
the file to be included. The Browse button allows you to select a file in the Select Libray dialog
box. The Send parameters check box must be off. Label and Comment are optional fields.
If you click with the right mouse button on one of the 3-phase reference objects, a similar dialog
appears with the difference that it has node name fields, too.
Application Manual
ATPDraw for Windows version 3.5 185
The reference objects are not represented in the .atp data file. Their role is just the visualization
of the connectivity. The ATPDraw generated ATP-file is shown below:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW June, Sunday 30, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
1.E-6 .001
500 1 1 1 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
X0011A 10. 0
X0011B 10. 0
X0011C 10. 0
X0013A 10. 0
X0013B 10. 0
X0013C 10. 0
X0015A 10. 0
X0015B 10. 0
X0015C 10. 0
X0017A 10. 0
X0017B 10. 0
X0017C 10. 0
C Study of ground fault in line A - B
$INCLUDE, D:\ATPDRAW3\USP\LIB.LIB
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
X0011AF1A .033 2. 0
X0011BF1B 2. 2. 0
X0011CF1C 2. 2. 0
X0013AF2A 2. 2. 0
X0013BF2B 2. 2. 0
X0013CF2C 2. 2. 0
X0015AF3A 2. 2. 0
X0015BF3B 2. 2. 0
X0015CF3C 2. 2. 0
X0017AF4A 2. 2. 0
X0017BF4B 2. 2. 0
X0017CF4C 2. 2. 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
/INITIAL
/OUTPUT
F2A F2B F2C
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
When creating the ATP-file above the Insert $Prefix and $Suffix cards was unselected on the ATP
| Settings | Format page, so the full path of the library file was written to the ATP-file in this
example. Otherwise, if this option would have been selected, the library files were supposed to be
located in the \USP folder and have the extension .LIB. Each library file specification is verified
to meet these requirements. If the path of a library file specifies a different folder or the extension
is not .LIB, an error dialog is displayed during the ATP-file generation process, enabling the user
to correct the erroneous specification by stripping off the path and extension, continue the
Application Manual
186 ATPDraw for Windows version 3.5
operation using an un-resolvable ATP include reference, or cancel the entire ATP-file generating
process. Fig. 6.10 shows this error dialog, as an example.
Fig. 6.10 - Error dialog when un-resolvable LIB-file specification was detected.
6.4 Modeling an HVDC station (Exa_6.adp and Exa_6g.adp)
In section 5.8.1 of the Advanced Manual, it is shown how to create a 6-pulse controlled thyristor-
rectifier bridge and make it available in ATPDraw as a user specified single object. In this part of
the manual, a practical example with the use of this user specified library object to build up a 12-
pulse HVDC station will be shown. The example is based on exercise 54 in [2]. Two different
project file format exists in the ATPDraw distribution:
a) Exa_6.adp: The thyristor bridge and its control is specified as user specified object by
means of the DATA BASE MODULARIZATION feature of ATP and interfaced with the rest of the
circuit via a $Include call.
b) Exa_6g.adp: The thyristor firing is simulated directly in ATPDraw by means of the TACS
support and connected with the thyristors via coupling to TACS objects. Finally, it is shown
how to compress the control circuit and valves into a single icon to get a similar circuit layout
than in case a).
The first alternative (Exa_6.adp) is shown in Fig. 6.11, the second one (Exa_6g.adp) in Fig.
6.13. The HVDC station in both circuits is supplied by a 3-phase AC source in front of two
transformers. Fig. 6.12 shows the data input dialog box of the new object. As it can be seen, the
source frequency is not one of the input parameters of the USP object. The frequency is "hard-
wired" in the DATA BASE MODULE code, which means that this circuit works only for 60 Hz
systems. For systems of 50 Hz the library file HVDC_65.LIB should be used. This object is also
given in the lower left corner of the circuit as hidden object.
Fig. 6.11 - 12-pulse HVDC station (Exa_6.adp)
Application Manual
ATPDraw for Windows version 3.5 187
Fig. 6.12 - Input dialog box of the users specified 6-pulse rectifier bridge.
Fig. 6.13 - 12-pulse HVDC station (Exa_6g.adp).
Compressing the valves and their control into a single HVDC group object.
Application Manual
188 ATPDraw for Windows version 3.5
Fig. 6.14 - Input dialog box of the HVDC group object.
The ATP-file created by ATPDraw is shown next:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Monday 1, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
2.E-5 .035
500 1 1 1 1 0 0 1 0
TACS HYBRID
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
TRANSFORMER TX0001 1.E12 1
9999
1VA .1 98.57 1.
2VS1MA XX0017 .022 21.59 .468
TRANSFORMER TX0001 TX0002
1VB
2VS1MB XX0017
TRANSFORMER TX0001 TX0003
1VC
2VS1MC XX0017
VS1MA VS1XXA .0001 1
VS1MB VS1XXB .0001 1
VS1MC VS1XXC .0001 1
XX0017 1.E7 0
VSA VA .0001 1
VSB VB .0001 1
VSC VC .0001 1
TRANSFORMER TX0004 1.E12 1
9999
1VA VC .3 295.7 1.
2VS2MA XX0032 .022 21.59 .2702
TRANSFORMER TX0004 TX0005
Application Manual
ATPDraw for Windows version 3.5 189
1VB VA
2VS2MB XX0032
TRANSFORMER TX0004 TX0006
1VC VB
2VS2MC XX0032
VS2MA VS2XXA .0001 1
VS2MB VS2XXB .0001 1
VS2MC VS2XXC .0001 1
XX0032 1.E7 0
POS1 XX0038 100. 0
POS1 XX0038 8.E3 0
XX0038IMP 15.35 1
POS1 POS2 1.E+9 2
$INCLUDE, D:\ATPDRAW3\USP\HVDC_6.LIB, VS1XX, POS1##, XX0078, VS1XXA, VS1XXC $$
, 18.2, 2500., 0.01
$INCLUDE, D:\ATPDRAW3\USP\HVDC_6.LIB, VS2XX, POS2##, ######, VS2XXA, VS2XXC $$
, 18.2, 2500., 0.01
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
POS2 XX0078 MEASURING 1
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14VSA 0 187794. 60. -60. -1. 1.
14VSB 0 187794. 60. -180. -1. 1.
14VSC 0 187794. 60. 60. -1. 1.
12IMP 0 229660. .01
/INITIAL
/OUTPUT
VA VB VC IMP POS1 POS2
BLANK TACS
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
Note the TACS HYBRID request marked as bold in the ATP-file. This is the result of the Insert
TACS HYBRID card check box selected under the Miscellaneous field of the ATP | Settings /
Format page. Leaving this request un-selected, ATPDraw would not know that TACS is present
in the USP library object HVDC_6. I.e. ATPDraw does not analyze the LIB-files before
connecting them via $Include to the circuit. It is similarly important to note that a full 5-character
node name (e.g. VS1XX) has to be used for the 3-phase node of the HVDC_6 object. It is because
the structure of the LIB-file requires A, B and C phase identifier letters are to be added as the 6th
character. Furthermore, the Internal phase seq indicator must be selected (see Fig. 6.12) to pass
the first parameter as a 3-phase node rather than 3 single-phase nodes, which is the default
procedure in ATPDraw.
Only case 1) below includes the HVDC_6.LIB into the ATP-file properly, where the node has a
5-character name and the Internal phase seq is active. The other two are equally bad and produce
a run time error or give incorrect results at the simulation because only 3-character name has been
specified in case 2) or the Internal phase seq was unselected in case 3):
1) $INCLUDE, HVDC_6, VS1XX, POS1##, XX0011, VS1XXA, VS1XXC . . .
2) $INCLUDE, HVDC_6, VS1##, POS1##, XX0011, VS1A##, VS1C## . . .
3) $INCLUDE, HVDC_6, VS1XXA, VS1XXB, VS1XXC, POS1##, XX0011, VS1XXA, VS1XXC
Using ATPDraw's TACS support for modeling the firing control and then compressing the circuit
into a single HVDC group, as shown in Fig. 6.13 seems a better alternative today, because the
restrictions and possible conflicts concerning the use of USP LIB-files do not exist.
Application Manual
190 ATPDraw for Windows version 3.5
In Fig. 6.15 four curves from the simulation is shown which are equal to the results in [2].
(file Exa_6.pl4; x-var t) v:POS1 c:VSA -VA v:POS2 c:POS2 -XX0078
0 5 10 15 20 25 30 35
[ms]
-200
-100
0
100
200
300
[kV]
-2000
-1000
0
1000
2000
3000
[A]
Fig. 6.15 - ATP simulation results.
6.5 Switching studies using JMarti LCC objects
The LCC modeling features of ATPDraw are described in detail in section 5.3 of the Advanced
Manual. Line modeling by LCC objects means that user specifies the geometrical arrangement and
material constants, then ATPDraw executes ATP's Line/Cable Constants routine and converts the
output punch-file to DBM library format. The resulting LIB-file will then be included in the final
ATP-file via a $Include call. The JMarti option is one out of the five alternatives supported by
ATPDraw's LCC object. Here two switching transient simulation examples are presented.
6.5.1 JMarti model of a 500 kV line (Exa_7.adp)
The 3-phase switching example (Exa_3.adp) created in section 6.1 of this manual is repeated
here. This time the 500 kV overhead line is represented by a frequency dependent 3-phase JMarti
model. The example circuit is shown in Fig. 6.16.
Fig. 6.16 - JMarti line in switching study (Exa_7.adp)
The overhead in this example is a 138 miles long single circuit 500 kV line (from John Day to
Lower Monumental in Oregon, USA) with two sky wires taken from ATP benchmark
DCN3.DAT. The line configuration is given in Fig. 6.17.
Application Manual
ATPDraw for Windows version 3.5 191
The line parameters are given in English units, the phase wires are represented by a tubular
conductor with parameters:
DC resistance = 0.05215 W/mile
Outside diameter of the conductor = 1.602 inch
Inner radius of the tube = 0.2178 inch
ATPDraw calculates the thickness/diameter value internally (T/D = 0.364).
The sky wires are solid, so inner radius is zero and T/D = 0.5. Other parameters are:
DC resistance = 2.61 W/mile
Outside diameter of the conductor = 0.386 inch.
The resistivity of the soil equals to 100 Wm. The conductor separation in the bundle is 18 inch.
Fig. 6.17 - Line configuration
The geometrical and material data of the system can be specified in a notebook style Line/Cable
Data window. This window appears when you click on the LCC object with the right mouse
button. The case Exa_7.adp requires a 3-phase un-transposed, frequency dependent line model
with segmented sky wires.
The JMarti line model is fitted in a frequency domain beginning from the standard data parameter
Freq. init up to an upper frequency limit specified by the mandatory parameter Decades. The
number of sample points per decade (Points/Dec) is given on the Model page of the Line/Cable
Data dialog box in Fig. 6.18. The model also requires a frequency (Freq. matrix) where the
transformation matrix is calculated and a steady state frequency (Freq. SS). The JMarti model
needs in some cases modification of the default fitting data under the optional Model fitting data
fields, which is not seen here because the default fitting option was selected by checking the Use
default fitting check box.
For further details please read in Chapter XVII of the ATP Rule Book [3].
50 feet
77.5 feet
98.5 feet
18 inch
12.9 feet
20 feet
Application Manual
192 ATPDraw for Windows version 3.5
Fig. 6.18 - Model and Data tab of the LCC object with parameters of the 500 kV line.
Click on OK or Run ATP will produce an ATP-file in the /LCC folder for the Line Constants run:
BEGIN NEW DATA CASE
JMARTI SETUP
$ERASE
BRANCH IN___AOUT__AIN___BOUT__BIN___COUT__C
LINE CONSTANTS
ENGLISH
10.364 0.05215 4 1.602 -20. 50. 50. 18. 0.0 2
20.364 0.05215 4 1.602 0.0 77.5 77.5 18. 0.0 2
30.364 0.05215 4 1.602 20. 50. 50. 18. 0.0 2
0 0.5 2.61 4 0.386 -12.9 98.5 98.5 0.0 0.0 0
0 0.5 2.61 4 0.386 12.9 98.5 98.5 0.0 0.0 0
BLANK CARD ENDING CONDUCTOR CARDS
100. 5.E3 138. 1 1
100. 60. 138. 1 1
100. 0.006 138. 1 8 5 1
BLANK CARD ENDING FREQUENCY CARDS
BLANK CARD ENDING LINE CONSTANT
DEFAULT
$PUNCH
BLANK CARD ENDING JMARTI SETUP
BEGIN NEW DATA CASE
BLANK CARD
Application Manual
ATPDraw for Windows version 3.5 193
Running this file through ATP will produce a punch-file (Exa_7.pch) which is not really
suitable for human reading, but ATPDraw is able to interpret this file and create a corresponding
Data Base Module file from it (Exa_7.lib), as shown next.
KARD 2 2 31 31 58 58
KARG 1 4 2 5 3 6
KBEG 3 9 3 9 3 9
KEND 8 14 8 14 8 14
KTEX 1 1 1 1 1 1
/BRANCH
-1IN___AOUT__A 2. 0.00 -2 3
15 4.8596368020077023000E+02
1.28826912392029580E+02 4.21314039036147750E+01 3.27778952656251990E+02
3.42120556154755430E+02 2.31706395896508240E+02 2.08786260934691540E+02
8.62925886209880100E+02 3.96364781680139640E+03 1.37750525571230360E+04
5.04922264466359770E+04 1.54260863950892210E+05 4.82293304155450430E+05
1.42128255471492070E+06 4.37886894143507820E+06 2.35545488812076410E+07
2.49826250993488740E-01 5.35615713798631380E-01 4.07281229680374720E-01
8.03651036437042830E-01 1.81278564570460170E+00 3.50385621765616320E+00
1.14057540636422540E+01 9.81963579148389560E+01 3.60242931544000040E+02
1.38337571722428290E+03 4.49207603871362970E+03 1.48303664468753290E+04
4.65501471695837030E+04 1.53448889755509940E+05 8.71318396896261490E+05
23 8.7989087598041335000E-04
1.44784195972755330E-03 1.72618900820032880E-02 6.08052951755686240E-02
8.18514563068449690E-02 9.80369133132474730E-02 1.19670680825931090E-01
1.31231913445598450E-01 2.01028497663409940E-01 4.26165440305758920E-01
6.72008875479658820E-01 1.63690540421784950E+00 1.35063945866398520E+01
4.94113434544494440E+01 4.72118615837808990E+02 1.09994157407951480E+02
3.98084617649364590E+02 1.97252185314118200E+03 -3.25277996569356590E+05
3.36699856999927960E+05 1.52216037007330470E+07 -1.48459577571328900E+07
6.82231163343569920E+06 -7.21239852086272930E+06
1.19519467829038910E+00 1.41873171368204220E+01 4.91197555820708370E+01
6.58453080123190380E+01 7.99351376189437840E+01 9.71814313439619750E+01
1.13224202499278870E+02 1.45016378017362630E+02 1.77978176494747060E+02
2.44963168811938940E+02 3.12085467108023010E+02 5.97017941683412120E+02
1.05402377130205200E+03 2.72111711154280650E+03 3.72369435171703710E+03
3.32780306542585230E+03 7.04198686695776360E+03 1.45520303377120560E+04
1.43985976617333420E+04 2.96607834650089170E+04 2.96904442484739270E+04
2.75651828836274870E+04 2.75927480665111000E+04
-2IN___BOUT__B 2. 0.00 -2 3
23 2.8643042611746085000E+02
3.08998260914488980E+02 1.42288050326312670E+00 6.90596379505970650E+01
1.79136618092116290E+02 3.24525036241582880E+02 2.96133850790243510E+02
3.41824951890173740E+02 4.11853983802918890E+02 1.42382589032593390E+02
1.28887340041081960E+02 1.36125501947475700E+02 6.35776945398324640E+01
6.41505060157885230E+01 4.97822097706220390E+01 6.78756601360499300E+01
8.83467501365563950E+01 1.44482788061671540E+03 1.30474379933331170E+03
1.33021422419579310E+03 6.91771032829592880E+03 4.24789323939575120E+04
2.56741633042442760E+05 9.11805594273185940E+05
2.21599645765206740E-01 2.55872380578820450E-01 3.21606113584952890E-01
6.00799388763468610E-01 1.19819873824012580E+00 2.03501892406855940E+00
3.49724209700450480E+00 6.11487873129203500E+00 9.36699962418260060E+00
1.36556697104026020E+01 2.12462616418538130E+01 3.45573854956540600E+01
6.20063668659757850E+01 9.06200519524050210E+01 1.23522352037827200E+02
1.55276035913140870E+02 2.46243597095036780E+03 2.19703777291054260E+03
2.08275779443450440E+03 1.14419917751103840E+04 7.03080060337777540E+04
4.25479974102484990E+05 1.51613003232333200E+06
12 7.5238143341787320000E-04
1.26187752330893370E-02 9.57417306869571230E+00 8.06553855901717750E+00
3.22916780804550920E+01 1.82284773566186430E+02 3.28717273491070230E+03
1.05469736021516550E+04 6.25519674328229450E+04 1.95037585481186280E+05
6.93793327828267360E+05 5.17768136297867890E+08 -5.18733585553731800E+08
2.79948727634371730E+00 2.14522724860313020E+03 1.73771414326436840E+03
6.76147405191892080E+03 9.92099341206001550E+03 6.41477741108265690E+04
1.02817538023626460E+05 2.13641697053375390E+05 3.61212659209385810E+05
1.30334940965001150E+06 8.03064526061047220E+05 8.03867590587109330E+05
-3IN___COUT__C 2. 0.00 -2 3
16 2.7264948016650357000E+02
2.67817005491046190E+02 7.71204920995468940E+01 1.05392796774480220E+01
2.06582282356138050E+02 2.92476838046614600E+02 2.53109974925397350E+02
3.88726504325862150E+02 4.86953611631485960E+02 4.88166400497281780E+01
Application Manual
194 ATPDraw for Windows version 3.5
1.66169955375051840E+02 1.29239096414975530E+02 1.21965197092375600E+02
5.96392678473994590E+01 2.70618243235187040E+03 6.07857003394846650E+03
2.37257840791754220E+05
2.10625410983532740E-01 2.55828054354881100E-01 2.99125254942318730E-01
6.08748241252635050E-01 1.15829187052544840E+00 1.95077180759634070E+00
3.59037789940054400E+00 6.45398556690523950E+00 9.01612071865698720E+00
1.49697084932160820E+01 2.16271239076000870E+01 3.55733792508496410E+01
6.13057163861530870E+01 2.30400350959367960E+03 5.24672997983652660E+03
2.04681439259560140E+05
22 7.5825845423326465000E-04
2.20731340332155700E-03 8.80044308390158510E-03 1.67547403381400310E-01
3.38210124111855760E+00 4.84129319769218820E+00 5.09033384432569220E+00
5.10224088106603180E+00 6.73212550175557480E+00 6.62153387662519320E+00
9.41335010019846590E+00 4.71274435719055300E+01 3.14107222102525500E+02
1.15548032274707750E+03 5.54708706438469110E+03 5.75228052962539590E+04
5.44880732380170960E+05 -3.90321051349684770E+05 1.37373189871937010E+05
1.65367860810841260E+05 1.18542118698838820E+06 9.64975663973962550E+08
-9.66683013861545090E+08
1.05671037383603570E+00 4.22725304647530290E+00 8.05485324487847550E+01
1.58978414422771360E+03 2.24770604565210580E+03 2.38901260864032970E+03
2.52338910685068050E+03 3.16422187793352670E+03 3.41412051476461280E+03
4.72306721626081530E+03 1.07327518402612950E+04 3.92086218410649090E+04
3.11707656822105780E+04 7.75866280161038010E+04 2.71296348716925770E+05
4.94008668415039310E+05 5.07878665220420980E+05 7.56313129864476970E+05
1.19007030519145770E+06 4.62903423922179640E+06 2.78672081158244750E+06
2.78950753239403340E+06
0.57153211 0.70710678 -0.41762016
0.00000000 0.00000000 0.00000000
0.58881414 0.00000000 0.80696147
0.00000000 0.00000000 0.00000000
0.57153211 -0.70710678 -0.41762016
0.00000000 0.00000000 0.00000000
$EOF
ARG, IN___A, IN___B, IN___C, OUT__A, OUT__B, OUT__C
The ATPDraw generated ATP-file for this 500 kV example circuit is show next. The new JMarti
LCC object is interfaced with the rest of the circuit by a $Include call:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Monday 1, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
1.E-5 .2
500 3 0 0 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
51X0001ABUSA .55 8.98
52X0001BBUSB .711 11.857
53X0001CBUSC
X0001ABUSA 200. 0
X0001BBUSB 200. 0
X0001CBUSC 200. 0
X0008A 2.51 0
X0008B 2.51 0
X0008C 2.51 0
SENA 1.E7 0
SENB 1.E7 0
SENC 1.E7 0
$INCLUDE, D:\ATPDRAW3\LCC\EXA_7.LIB, SENA##, SENB##, SENC##, RECA##, RECB## $$
, RECC##
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
BUSA SENA .03333 10. 0
BUSB SENB .0361 10. 0
Application Manual
ATPDraw for Windows version 3.5 195
BUSC SENC .0388 10. 0
X0008ABUSA .13333 10. 0
X0008BBUSB .1361 10. 0
X0008CBUSC .1388 10. 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14X0001A 0 408248. 60. -1. 1.
14X0001B 0 408248. 60. -120. -1. 1.
14X0001C 0 408248. 60. 120. -1. 1.
/INITIAL
/OUTPUT
SENA SENB SENC RECA RECB RECC BUSA BUSB BUSC
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
The name of the LIB-file is specified by complete path in this example. If the Auto path (Insert
$Prefix and $Suffix) option would be selected on the ATP | Settings / Format page, ATPDraw
would specify the default prefix (D:\ATPDraw3\USP\) and suffix (.LIB) in the ATP-file. In
that case the LCC files had to be stored in the /USP folder (i.e. not in the default /LCC folder),
otherwise an un-resolvable path conflict would appear, as shown in Fig. 6.19. It is rather preferred
not to use Auto path option if LCC objects are used together with other user specified library
objects. If the Auto path option is disabled, ATPDraw always enters the full path in the
$Include call making possible to keep the library files in different directories.
Fig. 6.19- Un-resolvable library file conflict.
Running the ATP data case will produce simulation results as shown in Fig. 6.20.
(file Exa_7.pl4; x-var t) v:SENA v:RECA
0.00 0.04 0.08 0.12 0.16 0.20
[s]
-800
-600
-400
-200
0
200
400
600
800
[kV]
Fig. 6.20 - Calculated voltages at sending and receiving end of the 500 kV line.
Application Manual
196 ATPDraw for Windows version 3.5
6.5.2 JMarti model of a 750 kV line
The JMarti line models introduced in this section will be used in the subsequent single-line-to-
ground fault study on a 750 kV shunt compensated transmission line with total length of 487 km.
Transpositions separate this line into four sections. Each section of the line is represented by 3-
phase un-transposed LCC object with JMarti option enabled. The ATPDraw project of the SLG
study includes four such objects with name LIN750_x.ALC, where x runs from 1 to 4. The line
configuration is shown in Fig. 6.21.
Fig. 6.21 - Tower configuration of the 750 kV line.
The line parameters are given in Metric units. The Auto bundling option is enabled to simplify the
data entry for this 4 conductor/phase in rectangular arrangement system. Tubular assumption has
been applied as in the previous example with the following parameters:
DC resistance = 0.0585 W/km
Outside diameter of the conductors = 3.105 cm.
Inner radius of the tube = 0.55 cm
ATPDraw calculates the thickness/diameter value internally (T/D = 0.32).
Sky wires are made from steel reinforced conductors, thus tubular assumption applies here, too:
DC resistance = 0.304 W/km
Outside diameter of the sky wire = 1.6 cm
Inner radius of the tube = 0.3 cm
ATPDraw calculates the thickness/diameter value internally (T/D = 0.187).
The resistivity of the soil equals to 20 Wm. The conductor separation in the bundle is 60 cm.
Entering the geometrical, material data and model options of the line, then executing Run ATP
will produce a LIB-file in the /LCC folder. Since the length of each section is different, four LCC
objects with different name are needed. The Save As button of the LCC dialog box can be used to
save the .ALC file with the new length, thus the line parameters need not be entered from scratch.
At tower = 41.05 m
Midspan = 26.15 m
Separ=60 cm
Alpha=45
NB=4
13.2 m
17.5 m
At tower = 27.9 m
Midspan = 13.0 m
Application Manual
ATPDraw for Windows version 3.5 197
Fig. 6.22- LCC Model and Data tab of the 1
st
section of the 750 kV line.
BEGIN NEW DATA CASE
JMARTI SETUP
$ERASE
BRANCH IN___AOUT__AIN___BOUT__BIN___COUT__C
LINE CONSTANTS
METRIC
10.323 0.0585 4 3.1 -17.5 27.9 13. 60. 45. 4
20.323 0.0585 4 3.1 0.0 27.9 13. 60. 45. 4
30.323 0.0585 4 3.1 17.5 27.9 13. 60. 45. 4
00.313 0.304 4 1.6 -13.2 41.05 26.15 0.0 0.0 0
00.313 0.304 4 1.6 13.2 41.05 26.15 0.0 0.0 0
BLANK CARD ENDING CONDUCTOR CARDS
20. 1.E3 84.6 1
20. 50. 84.6 1
20. 0.005 84.6 7 10 1
BLANK CARD ENDING FREQUENCY CARDS
BLANK CARD ENDING LINE CONSTANT
DEFAULT
$PUNCH
BLANK CARD ENDING JMARTI SETUP
BEGIN NEW DATA CASE
BLANK CARD
Application Manual
198 ATPDraw for Windows version 3.5
6.5.3 Line to ground fault and fault tripping transients (Exa_7a.adp)
Single-phase to ground fault transients on a 750 kV interconnection are investigated in this study.
The one-line diagram of the simulated network is shown in Fig. 6.23. At the sending end of the
line shunt reactors are connected with neutral reactors to reduce the secondary arc current during
the dead time of the single phase reclosing. The staged fault has been initiated at the receiving end
of the line.
750 kV tr. line
6000 MVA
6000 MVA
Single phase
to ground fault
478 km
750
3
D
D
750 kV
400 kV
1100 MVA
1100 MVA
400 kV
10000 MVA
Fig. 6.23 - One line diagram of the faulted line.
The layout of the completed ATPDraw circuit is shown in Fig. 6.24. Along the route three
transposition exist, so each LCC object represents a line section between two transpositions with
length 84.6 km, 162.7 km, 155.9 km, 75.7 km, respectively.
Fig. 6.24 - Line-to-ground fault study (Exa_7a.adp)
The supply network model is rather simple: a Thevenin equivalent 50 Hz source and a parallel
resistor representing the surge impedance of the lines erected from the 400 kV bus. An uncoupled
series reactance simulates the short circuit inductance of the 400/750 kV transformer bank. The
single-phase shunt reactors are represented by linear RLC components. Nononlinearities need not
been considered here, because the predicted amplitude of the reactor voltage is far below the
saturation level of the air gapped core. The impedance of the fault arc is considered as 2 ohm
constant resistance.
The ATPDraw generated ATP-file for this 750 kV example circuit is shown next:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Monday 1, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
2.E-5 .5
500 3 0 0 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
Application Manual
ATPDraw for Windows version 3.5 199
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
SLG_A 2. 0
XX0008 1. 300. 0
X0012CX0014C 5. 180. 0
X0012AX0014A 5. 180. 0
X0012BX0014B 5. 180. 0
X0012CX0014C 150. 0
X0012AX0014A 150. 0
X0012BX0014B 150. 0
X0022CX0021C 5. 300. 0
X0022AX0021A 5. 300. 0
X0022BX0021B 5. 300. 0
X0022CX0021C 150. 0
X0022AX0021A 150. 0
X0022BX0021B 150. 0
RECVC 20. 6.E3 0
RECVA 20. 6.E3 0
RECVB 20. 6.E3 0
X0014CX0017C 2. 200. 0
X0014AX0017A 2. 200. 0
X0014BX0017B 2. 200. 0
SENDC XX0008 10. 3.E3 0
SENDA XX0008 10. 3.E3 0
SENDB XX0008 10. 3.E3 0
$INCLUDE, D:\ATPDRAW3\LCC\LIN750_2.LIB, TRAN1B, TRAN1C, TRAN1A, TRAN2B $$
, TRAN2C, TRAN2A
$INCLUDE, D:\ATPDRAW3\LCC\LIN750_1.LIB, LN1C##, LN1A##, LN1B##, TRAN1C $$
, TRAN1A, TRAN1B
$INCLUDE, D:\ATPDRAW3\LCC\LIN750_3.LIB, TRAN2A, TRAN2B, TRAN2C, TRAN3A $$
, TRAN3B, TRAN3C
$INCLUDE, D:\ATPDRAW3\LCC\LIN750_4.LIB, TRAN3C, TRAN3A, TRAN3B, RECVC# $$
, RECVA#, RECVB#
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
RECVC SLG_A .0285 .225 10. 0
X0017CSENDC -1. .075 0
X0017ASENDA -1. 1. 0
X0017BSENDB -1. 1. 0
SENDC LN1C MEASURING 1
SENDA LN1A MEASURING 1
SENDB LN1B MEASURING 1
RECVC X0022C -1. .075 0
RECVA X0022A -1. 1. 0
RECVB X0022B -1. 1. 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14X0012C 0 612300. 50. -1. 1.
14X0012A 0 612300. 50. -120. -1. 1.
14X0012B 0 612300. 50. 120. -1. 1.
14X0021C 0 612300. 50. 10. -1. 1.
14X0021A 0 612300. 50. -110. -1. 1.
14X0021B 0 612300. 50. 130. -1. 1.
/INITIAL
/OUTPUT
SENDC SENDA SENDB RECVC RECVA RECVB
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
Fig. 6.25 shows the results of the simulation. The upper curve is the phase-to-ground voltage at
the receiving end of the line. Following the secondary arc extinction an oscillating trapped charge
appears on the faulty phase, which is the characteristics of the shunt compensated lines. The blue
(lower) curve shows the line current at the faulty phase during the fault and henceforth.
Application Manual
200 ATPDraw for Windows version 3.5
Fig. 6.26 shows the recorded phase voltages and line currents obtained by a high-speed transient
recorder at a staged fault tests of the same 750 kV line.
0.0 0.1 0.2 0.3 0.4 0.5
[s]
-700
-350
0
350
700
[kV]
0.0 0.1 0.2 0.3 0.4 0.5
[s ]
-3000
-2000
-1000
0
1000
2000
[A]
Fig. 6.25 - SLG fault and fault clearing transients (simulation).
upper curve: phase to ground voltage, lower curve: line current
Fig. 6.26 - SLG fault and fault clearing transients. Phase currents and voltages recorded at a staged
fault test by a variable sampling frequency disturbance recorder.
Application Manual
ATPDraw for Windows version 3.5 201
6.6 Using MODELS controlled switches (DC68.DAT) (Exa_8.adp)
This example is taken from the sub-case 9 of ATP benchmark file DC68.DAT, in which a series
compensated 500 kV interconnection is outlined. As a rule, metal-oxide arresters protect the series
capacitors against overheating in such circuits. In practice the arresters' energy dissipation is
continuously monitored and if certain power or energy limits are exceeded the series capacitor is
bypassed by a switch. In the simulation, the monitoring function is provided by a MODELS object
and the bypass function is by a TACS/MODELS controlled switch. Chapter 5.5.2 of the Advanced
Manual introduce you how to create the MODELS object applied in this example. The actual
circuit is shown in Fig. 6.27.
Fig. 6.27 - Usage of MODELS objects in ATPDraw (Exa_8.adp)
As Fig. 6.27 shows, no connections are drawn between the three MODELS object and the nodes
in the electrical network. This connection is made by the ATP logic by specifying identical name
for the MODELS output node and for the control node of the TACS switch. This will result in a
warning such as shown in Fig. 6.28 when creating the ATP-file, which can be ignored in this case
by clicking on OK. If you chose the next button Abort then re-draw the circuit the nodes with
identical name will be printed in cyan color.
Fig. 6.28 - Warning message that can be ignored here.
If you wish, you can use the Draw relation feature (TACS | Draw relation of the component
selection menu) to visualize the connection between the MODELS objects and the electrical
network.
Application Manual
202 ATPDraw for Windows version 3.5
If you click the right mouse button on the object controlling GAPA, an input dialog box appears
where you can specify the attributes. The Model file: field is the name and path of the file, in
which depicts the operation of the object according to the syntax of the MODELS simulation
language [4]. The Use As field may contain any name, but the name must be different for the three
MODELS object in Fig. 6.27.
Fig. 6.29 - Attributes of the MODELS object FLASH_1.
If you right click on one of the arresters an input window appears where you can specify the
parameters. In section 4.5 of the Reference Manual, the use of the Attributes and Characteristic
page of ZnO arresters are explained in detail.
The characteristics of ZnO arresters cannot be specified directly by exponential functions in
ATPDraw, since ATPDraw uses the current/voltage characteristic and performs an exponential
fitting internally. An external nonlinear characteristic can be taken into account using $Include,
however. This requires a text file named e.g. ZNO_1.LIB and stored in the \USP directory on
the form:
1.0 40. .80
9999.
The name of this LIB-file can be specified in $Include field of the Characteristic page and the
Include characteristic button should be selected. The user must be careful with $Prefix and
$Suffix use when the include files are located in different sub-directories. E.g. in this example the
nonlinear characteristic of the ZnO blocks are located in the \USP folder and the MODELS
object description file is in the \MOD folder. To avoid conflicts users are advised to specify the
full path of all include files, or copy all include files into the same subdirectory \LIB.
Application Manual
ATPDraw for Windows version 3.5 203
The new Grouping feature of ATPDraw (see in section 5.1 of this manual) provides an alternative
way for the TACS switch and MODELS object representation. This circuit is shown in Fig. 6.30,
and the name of the project file is Exa_8g.adp.
Fig. 6.30 - TACS switch and MODELS object compressed into a group.
The ATP-file of the example circuit is shown on the next 3 pages. The Record requests, which
result in MODELS variable output in the PL4-file, are marked bold in the data file. These requests
can be specified under ATP | Settings / Record as shown in Fig. 6.31. PRINTER PLOT requests
cards, which are also part of the original DC68.DAT are not much used today, so were omitted.
Similarly the original data case includes a clock-wise rotating 3-phase voltage source (negative
sequence), which is not reproduced here. It could be reproduced easily by replacing the 3-phase
sources with three single-phase sources of independent delay angle, or make these changes
manually by means of the ATP | Edit ATP-file feature and run the data case by the Run ATP (file)
command.
Fig. 6.31 - Selecting MODELS variables for output.
Application Manual
204 ATPDraw for Windows version 3.5
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Wednesday 3, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
C dT >< Tmax >< Xopt >< Copt >
5.E-5 .05 60.
1 9 0 0 1 -1 0 1 0
5 5 20 20 100 100 0 0
MODELS
/MODELS
INPUT
IX0001 {v(CR30A )}
IX0002 {v(CR20A )}
IX0003 {i(CRZ2A )}
IX0004 {v(CR30B )}
IX0005 {v(CR20B )}
IX0006 {i(CRZ2B )}
IX0007 {v(CR30C )}
IX0008 {v(CR20C )}
IX0009 {i(CRZ2C )}
OUTPUT
GAPA
GAPB
GAPC
MODEL FLASH_1
comment ****************************************************************
* *
* Function: set or cancel the gap firing control signal *
* Inputs : voltage and current across ZnO resistor *
* Output : the firing signal to the electrical ZnO component *
* *
************************************************************* endcomment
INPUT V1 -- Voltage on positive side of ZNO [V]
V2 -- Voltage of negative side of ZNO [V]
iczn -- ZNO current [Amps]
DATA Pset -- power setting [Megajoules/msec]
Eset -- energy setting [Megajoules]
fdel -- firing delay [msec]
fdur -- firing duration [msec]
VAR power -- power into ZnO resistor [Watts]
trip -- gap firing control signal [0 or 1]
energy -- energy into ZnO resistor [Joules]
tfire -- time at which the gap was last fired [sec]
vcap -- voltage difference across series caps [Volts]
OUTPUT trip
HISTORY INTEGRAL(power) {DFLT:0}
INIT trip:=0
tfire:=0
ENDINIT
EXEC
-----------------------------------------------------------------
vcap:=V1-V2
power:=vcap*iczn
energy:=INTEGRAL(power)
-----------------------------------------------------------------
IF trip>0 -- is already firing
AND t-tfire>fdur*1.e-3 -- has exceeded firing duration
THEN
trip:=0 -- cancel the firing signal
tfire:=0 -- null the firing time
ENDIF
-----------------------------------------------------------------
IF trip=0 -- is not signaling to fire
AND tfire=0 -- firing condition not yet detected
AND ( power >= Pset * 1.e9 -- power setting exceeded
OR energy >= Eset * 1.e6 ) -- energy setting exceeded
THEN
tfire:=t -- set the firing detection time
ENDIF
IF trip=0 -- is not signaling to fire
Application Manual
ATPDraw for Windows version 3.5 205
AND tfire>0 -- firing condition has been detected
AND t-tfire>=fdel*1.e-3 -- firing delay exceeded
THEN
trip:=1 -- set the firing signal
ENDIF
ENDEXEC
ENDMODEL
USE FLASH_1 AS FLASH_1A
INPUT
V1:= IX0001
V2:= IX0002
iczn:= IX0003
DATA
Pset:= 1.
Eset:= 9.
fdel:= 4.
fdur:= 20.
OUTPUT
GAPA :=trip
ENDUSE
USE FLASH_1 AS FLASH_1B
INPUT
V1:= IX0004
V2:= IX0005
iczn:= IX0006
DATA
Pset:= 1.
Eset:= 9.
fdel:= 4.
fdur:= 20.
OUTPUT
GAPB :=trip
ENDUSE
USE FLASH_1 AS FLASH_1C
INPUT
V1:= IX0007
V2:= IX0008
iczn:= IX0009
DATA
Pset:= 1.
Eset:= 9.
fdel:= 4.
fdur:= 20.
OUTPUT
GAPC :=trip
ENDUSE
RECORD
FLASH_1A.vcap AS VCAPA
FLASH_1A.power AS PZNA
FLASH_1A.energy AS EZNA
FLASH_1A.trip AS GAPA
ENDMODELS
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
51SRC1A RAVBA .1 20.
52SRC1B RAVBB .1 18.5
53SRC1C RAVBC
51SRC1A RAVBA 300.
52SRC1B RAVBB 150.
53SRC1C RAVBC
51CR50A CR30A .5 14.
52CR50B CR30B 8. 52.
53CR50C CR30C
CR30A CR20A 93.4 0
CR30B CR20B 93.4 0
CR30C CR20C 93.4 0
CRZ2A CRZ1A .01 1
CRZ2B CRZ1B .01 1
CRZ2C CRZ1C .01 1
Application Manual
206 ATPDraw for Windows version 3.5
92X0102AX0104A 5555. 0
147500. -1. 1
$INCLUDE, D:\ATPDRAW3\USP\ZNO_1.LIB
92X0102BX0104BX0102AX0104A 5555. 0
92X0102CX0104CX0102AX0104A 5555. 0
$VINTAGE,1
CR25A CR20A 5. 5. 5. 0
CR25B CR20B 5. .23 0
CR25C CR20C 5. .23 0
CR25A CR20A 200. 200. 200. 0
CR25B CR20B 200. 0
CR25C CR20C 200. 0
$VINTAGE,0
51CR20A CR01A .4 9.
52CR20B CR01B 5. 36.
53CR20C CR01C
51X0048AX0050A .5 14.
52X0048BX0050B 8. 52.
53X0048CX0050C
X0050AX0104A 93.4 0
X0050BX0104B 93.4 0
X0050CX0104C 93.4 0
X0100AX0102A .01 0
X0100BX0102B .01 0
X0100CX0102C .01 0
$VINTAGE,1
X0132AX0104A 5. 5. 5. 0
X0132BX0104B 5. .23 0
X0132CX0104C 5. .23 0
X0132AX0104A 200. 200. 200. 0
X0132BX0104B 200. 0
X0132CX0104C 200. 0
$VINTAGE,0
51GRCBA SRC2A .1 7.
52GRCBB SRC2B .1 10.7
53GRCBC SRC2C
51GRCBA SRC2A 350.
52GRCBB SRC2B 150.
53GRCBC SRC2C
51X0104AX0073A .4 9.
52X0104BX0073B 5. 36.
53X0104CX0073C
92CRZ1A CR20A 5555. 0
147500. -1. 1
$INCLUDE, D:\ATPDRAW3\USP\ZNO_1.LIB
92CRZ1B CR20B CRZ1A CR20A 5555. 0
92CRZ1C CR20C CRZ1A CR20A 5555. 0
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
RAVBA CR50A -1. 10. 0
RAVBB CR50B -1. 10. 0
RAVBC CR50C -1. 10. 0
CR30A CRZ2A -1. 1. 0
CR30B CRZ2B -1. 1. 0
CR30C CRZ2C -1. 1. 0
13CR30A CR25A CLOSED GAPA 0
13CR30B CR25B GAPB 0
13CR30C CR25C GAPC 0
CR01A GRCBA -0.006 10. 0
CR01B GRCBB -0.006 10. 0
CR01C GRCBC -0.006 10. 0
RAVBA X0048A -1. 10. 0
RAVBB X0048B -1. 10. 0
RAVBC X0048C -1. 10. 0
X0050AX0100A -1. 1. 0
X0050BX0100B -1. 1. 0
X0050CX0100C -1. 1. 0
X0050AX0132A -1. 10. 0
X0050BX0132B -1. 10. 0
X0050CX0132C -1. 10. 0
X0073AGRCBA -1. 10. 0
X0073BGRCBB -1. 10. 0
Application Manual
ATPDraw for Windows version 3.5 207
X0073CGRCBC -1. 10. 0
CR20A .01998 10. 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14SRC1A 0 4.4E5 60. -20. -1. 10.
14SRC1B 0 4.4E5 60. -140. -1. 10.
14SRC1C 0 4.4E5 60. 100. -1. 10.
14SRC2A 0 4.4E5 60. -1. 10.
14SRC2B 0 4.4E5 60. -120. -1. 10.
14SRC2C 0 4.4E5 60. 120. -1. 10.
/INITIAL
/OUTPUT
BLANK MODELS
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
6.7 Lightning overvoltage study in a 400 kV substation (Exa_9.adp)
This example demonstrates the use of ATPDraw in a lightning protection study. The one-line
diagram of the investigated 400 kV substation is drawn in Fig. 6.32. The numbers written on the
top of the bus sections specify the length in meters. The simulated incident is a single-phase back-
flashover caused by a lightning strike to the tower structure 900 m away from the substation.
Severe lightning parameters were chosen with 120 kA amplitude and 4/50 ms front/tail times. In
the investigated cases, only Line1 and Line2 are connected with the transformer bus. The
transformer is protected by conventional SiC arresters.
22
LINE3
TR
LINE2 LINE1
LINE5 LINE4
22 22 15 15
15 15 22 22 22
15
12
57
10
15
12
15
12
15
12
57
10
15
12
57
8 8
5
10
12
25
68
12 12
68
15 15
24
57 57
13
24
13
15
13
24
5
10
5
10
5
10
5
5
10
5
13
24
15
13
24
15
7
17 51
PT1 PT2 PT3
Conventional
gapped arrester
PT4 PT5
Fig. 6.32 - One-line diagram of the substation
Application Manual
208 ATPDraw for Windows version 3.5
Fig. 6.33 - Example circuit (Exa_9.adp)
The ATPDraw circuit of the complete network (substation+incoming line) is shown in Fig. 6.33.
The Copy&Paste or Grouping (Compress) feature of ATPDraw could be used effectively when
creating such a model because the circuit has many identical blocks. I.e. the user needs to define
the object parameters only once and copy them as many times as needed.
Close to the lightning strike, the line spans are represented by 4-phase JMarti LCC objects (phase
conductors + sky wire). The surge propagation along the tower structure has been taken into
account in this model by representing the vertical pylon sections as single-phase constant
parameter transmission lines. The R-L branches below the tower model simulate the tower
grounding impedance. The front of wave flashover characteristic of the line insulators plays a
significant role in such a back-flashover study. It can be simulated quite easily using a MODELS
object - like the Flash of this example-, which controls a TACS/MODELS controlled switch.
The influence of the power frequency voltage on the back-flashover probability can't be neglected
either at this voltage level. In this study case, it was considered by a Thevenin equivalent 3-phase
source connected to the remote end of Line2.
The ATP-file created by ATPDraw is shown below. Note! This case exceeds the storage cell limit
of ATP if the program runs with DEFAULT=3.0 table size (default LISTSIZE.DAT setting). To
run the simulation successfully the user must increase this limit from 3.0 to 6.0.
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Thursday 4, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
5.E-9 2.5E-5
500 3 0 0 1 0 0 1 0
MODELS
/MODELS
INPUT
IX0001 {v(TWR4A )}
IX0002 {v(XX0016)}
OUTPUT
XX0048
Application Manual
ATPDraw for Windows version 3.5 209
MODEL Flash
comment--------------------------------------
| Front of wave flashover characteristic |
| of the HV insulator. |
| Input: Voltage accross the insulator. |
| Output: Close command for the TACS switch |
-----------------------------------endcomment
INPUT UP, UN
OUTPUT CLOSE
DATA UINF {DFLT:650e3}, UO {DFLT: 1650e3}, TAU {DFLT:8.e-7}, UINIT {DFLT:1E5}
VAR CLOSE, TT, U, FLASH
INIT
CLOSE:=0
TT:=0
FLASH:=INF
ENDINIT
EXEC
U:= ABS(UP-UN)
IF (U>UINIT) THEN
TT:=TT+timestep
FLASH:=(UINF + (UO-UINF)*(EXP(-TT/TAU)))
IF (U>FLASH) THEN CLOSE:=1 ENDIF
ENDIF
ENDEXEC
ENDMODEL
USE FLASH AS FLASH
INPUT
UP:= IX0001
UN:= IX0002
DATA
UINF:= 1.4E6
UO:= 3.E6
TAU:= 8.E-7
UINIT:= 3.5E5
OUTPUT
XX0048:=CLOSE
ENDUSE
RECORD
FLASH.U AS U
FLASH.CLOSE AS CLOSE
ENDMODELS
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
-1XX0010XX0167 10. 200. 2.5E5 .008 1 0 0
-1XX0012XX0010 10. 200. 2.5E5 .007 1 0 0
-1XX0014XX0012 10. 200. 2.5E5 .018 1 0 0
-1XX0016TOP 10. 200. 2.5E5 .008 1 0 0
-1 XX0019 20. 600. 2.9E5 .3 1 0 0
-1XX0020XX0016 10. 200. 2.5E5 .007 1 0 0
XX0014 40. 0
XX0014 13. .005 0
-1XX0026XX0171 10. 200. 2.5E5 .008 1 0 0
-1XX0028XX0020 10. 200. 2.5E5 .018 1 0 0
-1X0032AX0033A 20. 650. 2.4E5 3. 1 0 0
-2X0032BX0033B 2. 400. 2.9E5 3. 1 0 0
-3X0032CX0033C 0
XX0028 40. 0
-1XX0036 20. 600. 2.9E5 .3 1 0 0
XX0028 13. .005 0
-1XX0040XX0179 10. 200. 2.5E5 .008 1 0 0
-1XX0042XX0040 10. 200. 2.5E5 .007 1 0 0
-1XX0044XX0042 10. 200. 2.5E5 .018 1 0 0
XX0044 40. 0
XX0044 13. .005 0
-1XX0054XX0183 10. 200. 2.5E5 .008 1 0 0
-1XX0056XX0026 10. 200. 2.5E5 .007 1 0 0
LIGHT 400. 0
-1XX0060XX0054 10. 200. 2.5E5 .007 1 0 0
-1XX0062XX0056 10. 200. 2.5E5 .018 1 0 0
Application Manual
210 ATPDraw for Windows version 3.5
-1XX0064XX0060 10. 200. 2.5E5 .018 1 0 0
XX0064 40. 0
-1XX0069XX0019 10. 200. 2.5E5 .008 1 0 0
XX0064 13. .005 0
-1X0073AX0074A 20. 400. 2.4E5 .008 1 0 0
-2X0073BX0074B 2. 260. 2.9E5 .008 1 0 0
-3X0073CX0074C 0
-1XX0075XX0036 10. 200. 2.5E5 .008 1 0 0
-1X0078AX0211A 20. 400. 2.4E5 .012 1 0 0
-2X0078BX0211B 2. 260. 2.9E5 .012 1 0 0
-3X0078CX0211C 0
-1X0257AX0081A 50. 650. 2.4E5 .015 1 0 0
-2X0257BX0081B 10. 360. 2.9E5 .015 1 0 0
-3X0257CX0081C 0
-1X0082AX0083A 20. 400. 2.4E5 .068 1 0 0
-2X0082BX0083B 2. 260. 2.9E5 .068 1 0 0
-3X0082CX0083C 0
-1X0271ALINE2A 20. 650. 2.4E5 .024 1 0 0
-2X0271BLINE2B 2. 360. 2.9E5 .024 1 0 0
-3X0271CLINE2C 0
-1X0086AX0269A 20. 400. 2.4E5 .012 1 0 0
-2X0086BX0269B 2. 260. 2.9E5 .012 1 0 0
-3X0086CX0269C 0
-1X0088AX0293A 20. 650. 2.4E5 .015 1 0 0
-2X0088BX0293B 2. 360. 2.9E5 .015 1 0 0
-3X0088CX0293C 0
-1X0074AX0090A 20. 400. 2.4E5 .015 1 0 0
-2X0074BX0090B 2. 260. 2.9E5 .015 1 0 0
-3X0074CX0090C 0
-1X0074AX0271A 20. 400. 2.4E5 .085 1 0 0
-2X0074BX0271B 2. 260. 2.9E5 .085 1 0 0
-3X0074CX0271C 0
X0271A .0005 0
X0271B .0005 0
X0271C .0005 0
-1X0269AX0211A 20. 650. 2.4E5 .022 1 0 0
-2X0269BX0211B 2. 360. 2.9E5 .022 1 0 0
-3X0269CX0211C 0
-1X0211AX0257A 20. 650. 2.4E5 .022 1 0 0
-2X0211BX0257B 2. 360. 2.9E5 .022 1 0 0
-3X0211CX0257C 0
99SICC 1.1E6 1. 1
100. 6.5E5
1.E3 7.6E5
2.E3 8.E5
4.E3 8.34E5
5.E3 8.5E5
1.E4 9.35E5
2.E4 1.082E6
3.E4 1.2E6
9999
-1X0104AX0105A 20. 400. 2.4E5 .068 1 0 0
-2X0104BX0105B 2. 260. 2.9E5 .068 1 0 0
-3X0104CX0105C 0
-1X0106AX0257A 20. 400. 2.4E5 .012 1 0 0
-2X0106BX0257B 2. 260. 2.9E5 .012 1 0 0
-3X0106CX0257C 0
-1X0108ATR400A 20. 650. 2.4E5 .017 1 0 0
-2X0108BTR400B 2. 360. 2.9E5 .017 1 0 0
-3X0108CTR400C 0
-1X0105AX0110A 20. 400. 2.4E5 .025 1 0 0
-2X0105BX0110B 2. 260. 2.9E5 .025 1 0 0
-3X0105CX0110C 0
99SICB 1.1E6 1. 1
100. 6.5E5
1.E3 7.6E5
2.E3 8.E5
4.E3 8.34E5
5.E3 8.5E5
1.E4 9.35E5
2.E4 1.082E6
3.E4 1.2E6
Application Manual
ATPDraw for Windows version 3.5 211
9999
-1PT1A LINE1A 20. 650. 2.4E5 .024 1 0 0
-2PT1B LINE1B 2. 360. 2.9E5 .024 1 0 0
-3PT1C LINE1C 0
-1X0118AX0293A 20. 400. 2.4E5 .012 1 0 0
-2X0118BX0293B 2. 260. 2.9E5 .012 1 0 0
-3X0118CX0293C 0
-1X0083AX0120A 20. 400. 2.4E5 .015 1 0 0
-2X0083BX0120B 2. 260. 2.9E5 .015 1 0 0
-3X0083CX0120C 0
TR400A .003 0
TR400B .003 0
TR400C .003 0
-1X0105AX0108A 20. 650. 2.4E5 .051 1 0 0
-2X0105BX0108B 2. 360. 2.9E5 .051 1 0 0
-3X0105CX0108C 0
-1SICA X0108A 20. 400. 2.4E5 .007 1 0 0
-2SICB X0108B 2. 260. 2.9E5 .007 1 0 0
-3SICC X0108C 0
99SICA 1.1E6 1. 1
100. 6.5E5
1.E3 7.6E5
2.E3 8.E5
4.E3 8.34E5
5.E3 8.5E5
1.E4 9.35E5
2.E4 1.082E6
3.E4 1.2E6
9999
X0132AX0133A 1. 50. 0
X0132BX0133B 1. 50. 0
X0132CX0133C 1. 50. 0
-1XX0135XX0075 10. 200. 2.5E5 .007 1 0 0
-1X0083APT1A 20. 400. 2.4E5 .085 1 0 0
-2X0083BPT1B 2. 260. 2.9E5 .085 1 0 0
-3X0083CPT1C 0
PT1A .0005 0
PT1B .0005 0
PT1C .0005 0
-1X0293AX0269A 20. 650. 2.4E5 .022 1 0 0
-2X0293BX0269B 2. 360. 2.9E5 .022 1 0 0
-3X0293CX0269C 0
-1XX0143XX0135 10. 200. 2.5E5 .018 1 0 0
XX0062 40. 0
XX0062 13. .005 0
-1XX0149XX0069 10. 200. 2.5E5 .007 1 0 0
-1XX0151XX0149 10. 200. 2.5E5 .018 1 0 0
XX0151 40. 0
XX0151 13. .005 0
XX0143 40. 0
XX0143 13. .005 0
-1LINE2AX0132A 20. 650. 2.4E5 3. 1 0 0
-2LINE2BX0132B 2. 360. 2.9E5 3. 1 0 0
-3LINE2CX0132C 0
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, X0033A, X0033B, X0033C, XX0019, X0166A $$
, X0166B, X0166C, XX0167
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, X0166A, X0166B, X0166C, XX0167, X0170A $$
, X0170B, X0170C, XX0171
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, X0170A, X0170B, X0170C, XX0171, TWR4A# $$
, TWR4B#, TWR4C#, TOP###
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, TWR4A#, TWR4B#, TWR4C#, TOP###, X0178A $$
, X0178B, X0178C, XX0179
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, X0178A, X0178B, X0178C, XX0179, X0182A $$
, X0182B, X0182C, XX0183
$INCLUDE, D:\ATPDRAW\LCC\EXA_9.LIB, X0182A, X0182B, X0182C, XX0183, LINE1A $$
, LINE1B, LINE1C, XX0036
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
LIGHT TOP MEASURING 1
X0090AX0086A -1. 1.001 0
X0090BX0086B -1. 1.001 0
X0090CX0086C -1. 1.001 0
Application Manual
212 ATPDraw for Windows version 3.5
X0110AX0106A -1. 1.001 0
X0110BX0106B -1. 1.001 0
X0110CX0106C -1. 1.001 0
X0120AX0118A -1. 1.001 0
X0120BX0118B -1. 1.001 0
X0120CX0118C -1. 1.001 0
13XX0016TWR4A XX0048 0
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
15LIGHT -1 1.2E5 4.E-6 5.E-5 5. 1.
14X0133A 0 -3.3E5 50. -1. 1.
14X0133B 0 -3.3E5 50. -120. -1. 1.
14X0133C 0 -3.3E5 50. 120. -1. 1.
/INITIAL
/OUTPUT
LINE1ALINE1BLINE1CTWR4A TWR4B TWR4C TR400ATR400BTR400CPT1A PT1B PT1C
BLANK MODELS
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
Some results of the simulation are drawn in Fig. 6.34. The blue line is the voltage stress appearing
at the transformer terminal, the red line shows the incoming surge measured at the voltage
transformer of Line1 (node PT1 of the circuit). The discharge current of the gapped arrester is
drawn at the bottom if the figure. As it can be seen, the instantaneous value of the power
frequency voltage was set opposite to the polarity of the lightning surge in the simulation.
(file Exa_9.pl4; x-var t) v:PT1A v:TR400A c:SICA -
0 5 10 15 20 25
[us]
-0.50
-0.25
0.00
0.25
0.50
0.75
1.00
1.25
1.50
[MV]
0
2
4
6
8
10
12
14
16
[kA]
Fig. 6.34 - ATP simulation results. Red: incoming surge at the substation entrance.
Blue: voltage stress at the transformer terminal. Green: arrester discharge current.
Application Manual
ATPDraw for Windows version 3.5 213
6.8 Simulating transformer inrush current transients
The magnetic coupling between the windings and the nonlinear characteristic of the magnetizing
reactance are the most important factors in transformer energizing transient studies. The BCTRAN
supporting routine of ATP can be used to derive the R L or (L
-1
R) matrix representation of a
single or 3-phase multi-winding transformer. ATPDraw now provides a similar interface to the
BCTRAN supporting routine like the one provided for the LCC objects. The BCTRAN input data
are the excitation and short circuit factory test data, which can easily be obtained from the
transformer manufacturers. Additionally, the user can select between several options for modeling
the nonlinear magnetizing branch.
The first example circuit of this section demonstrates the use of BCTRAN objects for transformer
energization studies. In the second example, readers are familiarized with the application of user
specified objects and the Grouping feature for transformer modeling.
6.8.1 Energization of a 400/132/18 kV auto-transformer (Exa_10.adp)
The study case is the energization of a 3-phase, three-winding Yyd coupled transformer. The wye
connected 132 kV windings and the delta coupled 18 kV windings are unloaded in this study. The
schematic diagram of the simulated case is shown in Fig. 6.35, the corresponding ATPDraw
circuit is depicted in Fig. 6.36.
63.7 mH
420
3
S
SC
= 8000 MVA
6nF 4nF
B
A
C
400/132/18 kV
250 MVA , Yyn0d11
200 ohm
Fig. 6.35 - One-line scheme of the transformer and the 400 kV source.
Fig. 6.36 - ATPDraw circuit (Exa_10.adp).
The nameplate data of the transformer are as follows:
Voltage rating V
high
/V
low
/V
tertiary
: 400/132/18 kV, Yyn0d11
Power rating: 250 MVA (75 MVA tertiary)
Positive seq. excitation loss/current: 140 kW / 0.2 %
Positive seq. reactance: High to Low: 15 % (S
base
=250MVA) 15 % (S
base
=250MVA)
High to Tertiary: 12.5 % (S
base
=75MVA) 41.6667 % (S
base
=250MVA)
Low to Tertiary: 7.2 % (S
base
=75MVA) 24 % (S
base
=250MVA)
Short circuit loss: High to Low: 710 kW
High to Tertiary: 188 kW
Low to Tertiary: 159 kW
Application Manual
214 ATPDraw for Windows version 3.5
In the BCTRAN dialog box, you specify first the number of phases and the number of windings per
phase under Structure (see Fig. 6.37). Under Ratings, the nominal line-to-line voltage, power
ratings, the type of coupling of windings and the phase shift must be entered. For auto-
transformers, the nominal voltage of the windings (which is the required input for BCTRAN) is
calculated automatically by ATPDraw and the short-circuit impedances are also re-defined
according to the Eq. 6.45, 6.46, 6.50 of the EMTP Theory Book [5]. The zero sequence excitation
and short circuit parameters are approximately equal to the positive sequence values for an auto-
transformer having tertiary delta winding, so the Zero sequence data available check boxes are
unselected in this example. The External Lm option is chosen under Positive core magnetization
because external Type-96 hysteretic inductors are used to represent the magnetizing inductance.
Accordingly, only the resistive component of the magnetizing current will be entered as IEXPOS
in the BCTRAN input file.
Fig. 6.37 - BCTRAN dialog box of the 400/132/18 kV transformer.
Following data specification the program offers to generate a BCTRAN input file and run ATP. It
can either be performed by a Run ATP requests, (without leaving the dialog box), or selecting OK.
If the BCTRAN-file is correct, a punch-file will be created. This file is directly included in the
final ATP-file and there is no conversion to a library file as for lines/cables. The BCTRAN input
file generated by ATPDraw is shown next. This file is given extension .atp and stored in the
/BCT folder.
Application Manual
ATPDraw for Windows version 3.5 215
BEGIN NEW DATA CASE
ACCESS MODULE BCTRAN
$ERASE
C Excitation test data card
C < FREQ >< IEXPOS >< SPOS >< LEXPOS ><IEXZERO >< SZERO ><LEXZERO ><><><><>
3 50. .05600056 250. 140. 0 2 3 0
C Winding data cards
C >< VRAT >< R >>< PHASE1 >< PHASE2 >< PHASE3 >
1 154.729872 H_BUSAL_BUSAH_BUSBL_BUSBH_BUSCL_BUSC
2 76.2102355 L_BUSA L_BUSB L_BUSC
3 18. T_BUSAT_BUSCT_BUSBT_BUSAT_BUSCT_BUSB
C Short-circuit test data cards
C <>< PIJ >< ZPOSIJ >< SPOS ><ZZEROIJ >< SZERO ><><>
1 2 710.33.4150145 250.33.4150145 250. 0 1
1 3 188.61.3951637 250.61.3951637 250. 0 1
2 3 159. 24. 250. 24. 250. 0 1
BLANK card ending short-circuit test data
$PUNCH
BLANK card ending BCTRAN data
BEGIN NEW DATA CASE
BLANK CARD
The nonlinear magnetizing branch of the 400/132/18 kV auto-transformer is represented by delta
coupled Type-96 hysteretic inductors in this study. The flux-current characteristic of these
inductors can be obtained by means of the HYSDAT supporting routine of ATP. Fig. 6.38 shows
the hysteresis loop of the Itype-1 material of ATP and of the magnetic core of the transformer.
-1.5
-1
-0.5
0
0.5
1
1.5
-2 -1.5 -1 -0.5 0 0.5 1 1.5 2
I [%]
PSI [p.u.]
Hyst+
Hyst-
Armco
Fig. 6.38 - The shape of the hysteresis loop of the transformer magnetic core
compared with the material type 1 of ATP's HYSDAT supporting routine.
The output file generated by the HYSDAT supporting routine is listed below. In this example the
file is given a name HYSTR400.LIB and stored in the /USP folder.
C <++++++> Cards punched by support routine on 21-Jul-02 14.08.23 <++++++>
C HYSTERESIS
C $ERASE
C C ITYPE LEVEL { Request Armco M4 oriented silicon steel -- only 1 availab
C 1 4 { That was ITYPE=1. As for LEVEL=2, moderate accuracy outp
C 98.2 97.2 { Current and flux coordinates of positive saturat
-3.68250000E+01 -9.49129412E+01
-2.45500000E+01 -9.43411765E+01
-1.10475000E+01 -9.23400000E+01
-4.91000000E+00 -9.03388235E+01
-1.84125000E+00 -8.86235294E+01
6.13750000E-01 -8.51929412E+01
2.14812500E+00 -8.11905882E+01
3.55975000E+00 -7.43294118E+01
Application Manual
216 ATPDraw for Windows version 3.5
4.29625000E+00 -6.28941176E+01
4.91000000E+00 -4.57411765E+01
6.13750000E+00 3.05894118E+01
6.75125000E+00 4.23105882E+01
8.59250000E+00 5.71764706E+01
1.10475000E+01 6.86117647E+01
1.33797500E+01 7.43294118E+01
1.74918750E+01 8.00470588E+01
2.39362500E+01 8.51929412E+01
3.28356250E+01 8.91952941E+01
4.29625000E+01 9.20541176E+01
6.13750000E+01 9.49129412E+01
9.82000000E+01 9.72000000E+01
1.35025000E+02 9.77717647E+01
9999.
Such a nonlinear characteristic can be connected to the Type-96 inductor in two ways: include as
an external file, or enter flux-current data pairs directly in the Characteristic page as shown in Fig.
6.39. The Copy and Paste buttons of the dialog box provide a powerful way to import the whole
characteristic from an external text file via the Windows clipboard or export it to another Type96
objects. It is thus possible to bring a HYSDAT punch-file up in a text editor, mark the
characteristic, copy it to the clipboard and paste it into the Characteristic page. The number of
data however must be less or equal to 36. In practice it means that you cannot select HYSDAT
input parameter Level = 4. No such limit exists for the included nonlinear characteristics.
Fig. 6.39 - Importing the nonlinear characteristic from a HYSDAT punch-file.
The complete ATP input file generated by ATPDraw for this study case is listed next:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Sunday 21, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
5.E-6 .15
500 5 0 0 1 0 0 1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
Application Manual
ATPDraw for Windows version 3.5 217
L_BUSA .004 0
L_BUSB .004 0
L_BUSC .004 0
SOURCASUPLA 2. 63.7 0
SOURCBSUPLB 2. 63.7 0
SOURCCSUPLC 2. 63.7 0
SOURCASUPLA 200. 0
SOURCBSUPLB 200. 0
SOURCCSUPLC 200. 0
T_BUSA .01 0
T_BUSB .01 0
T_BUSC .01 0
96T_BUSBT_BUSC 8888. 0.0 1
-36.825 -94.9129412
-18.4125 -93.7694118
-6.1375 -90.9105882
-1.2275 -88.0517647
2.148125 -81.1905882
4.05075 -68.6117647
7.365 49.1717647
11.66125 70.3270588
16.57125 78.9035294
24.55 85.7647059
36.21125 90.3388235
56.465 93.7694118
98.2 97.2
135.025 97.7717647
9999
96T_BUSAT_BUSB 8888. 0.0 1
-36.825 -94.9129412
-18.4125 -93.7694118
-6.1375 -90.9105882
-1.2275 -88.0517647
2.148125 -81.1905882
4.05075 -68.6117647
7.365 49.1717647
11.66125 70.3270588
16.57125 78.9035294
24.55 85.7647059
36.21125 90.3388235
56.465 93.7694118
98.2 97.2
135.025 97.7717647
9999
96T_BUSCT_BUSA 8888. 0.0 1
-36.825 -94.9129412
-18.4125 -93.7694118
-6.1375 -90.9105882
-1.2275 -88.0517647
2.148125 -81.1905882
4.05075 -68.6117647
7.365 49.1717647
11.66125 70.3270588
16.57125 78.9035294
24.55 85.7647059
36.21125 90.3388235
56.465 93.7694118
98.2 97.2
135.025 97.7717647
9999
H_BUSA .006 0
H_BUSB .006 0
H_BUSC .006 0
$VINTAGE, 1,
1T_BUSAT_BUSC 6942.8436268432
2T_BUSBT_BUSA 0.0
6942.8436268432
3T_BUSCT_BUSB 0.0
0.0
6942.8436268432
USE AR
1H_BUSAL_BUSA 3.2888630659697 .42462348721612
Application Manual
218 ATPDraw for Windows version 3.5
2L_BUSA -7.231251366149 0.0
34.681001957452 .09492595191772
3T_BUSAT_BUSC 2.3450004639366 0.0
-84.67537379274 0.0
338.34949508527 0.0
4H_BUSBL_BUSB .1936225317E-15 0.0
-.677127449E-15 0.0
.1202491824E-14 0.0
3.2888630659697 .42462348721612
5L_BUSB -.677127449E-15 0.0
.2041578689E-14 0.0
-.282318606E-14 0.0
-7.231251366149 0.0
34.681001957452 .09492595191772
6T_BUSBT_BUSA .1202491824E-14 0.0
-.282318606E-14 0.0
-.6542678427E-4 0.0
2.3450004639366 0.0
-84.67537379274 0.0
338.34949508527 0.0
7H_BUSCL_BUSC .1936225317E-15 0.0
-.677127449E-15 0.0
.1202491824E-14 0.0
.1936225317E-15 0.0
-.677127449E-15 0.0
.1202491824E-14 0.0
3.2888630659697 .42462348721612
8L_BUSC -.677127449E-15 0.0
.2041578689E-14 0.0
-.282318606E-14 0.0
-.677127449E-15 0.0
.2041578689E-14 0.0
-.282318606E-14 0.0
-7.231251366149 0.0
34.681001957452 .09492595191772
9T_BUSCT_BUSB .1202491824E-14 0.0
-.282318606E-14 0.0
-.6542678427E-4 0.0
.1202491824E-14 0.0
-.282318606E-14 0.0
-.6542678427E-4 0.0
2.3450004639366 0.0
-84.67537379274 0.0
338.34949508527 0.0
$VINTAGE, 0,
$UNITS, -1.,-1.
USE RL
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
SUPLA H_BUSA -1. .045 1. 1
SUPLB H_BUSB -1. .045 1. 1
SUPLC H_BUSC -1. .045 1. 1
SUPLA H_BUSA .0735 1. 1
SUPLB H_BUSB .0785 1. 1
SUPLC H_BUSC .0785 1. 1
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14SOURCA 0 326600. 50. -1. 1.
14SOURCB 0 326600. 50. -120. -1. 1.
14SOURCC 0 326600. 50. 120. -1. 1.
/INITIAL
/OUTPUT
SUPLA SUPLB SUPLC H_BUSAH_BUSBH_BUSC
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BEGIN NEW DATA CASE
BLANK
Application Manual
ATPDraw for Windows version 3.5 219
Some results of the simulation are shown in Fig. 6.40. In the reported case, the steady state
magnetizing current of the unloaded transformer is interrupted at 45 ms producing high residual
flux in two phases. As a result, a high amplitude inrush current may occur at a subsequent
transformer energization.
(file exa_10.pl4; x-var t) c:SUPLA -H_BUSA c:SUPLB -H_BUSB c:SUPLC -H_BUSC
0 10 20 30 40 50
[ms]
-1.0
-0.5
0.0
0.5
1.0
[A]
(file exa_10.pl4; x-var t) c:SUPLA -H_BUSA c:SUPLB -H_BUSB c:SUPLC -H_BUSC
0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15
[s ]
-500
-250
0
250
500
[A]
Fig. 6.40 - Steady-state magnetizing current (upper curves) and the
inrush current (lower curves) at a subsequent energization.
6.8.2 Energization of a 132/15 kV generator step-up transformer (Exa_11.adp)
The use of the icon customization and the advantages of the grouping feature of ATPDraw are
demonstrated in this example. The simulated case is again a transformer switching study, in which
a 155 MVA 132/15 kV Y/d coupled step-up and a 4 MVA 15/6.9 kV D/d coupled auxiliary
transformer are energized together. The fast start gas turbine plant is located near to a 400/220/120
kV substation and the transformers are connected with the substation by a 120 kV single core
XLPE cable. During the step-up transformer energization the generator is still disconnected, so
need not be considered in this study. The ATPDraw circuit of the simulation is shown in Fig. 6.41.
Fig. 6.41 - ATPDraw circuit (Exa_11g.adp)
Application Manual
220 ATPDraw for Windows version 3.5
Fig. 6.41 shows several customized ATPDraw objects created by the Edit | Compress command.
If you are not familiar with this grouping feature please read in section 5.1 of this Advanced
Manual. This feature provides a powerful tool in advanced modeling. On Fig. 6.41 the nonlinear,
hysteretic transformer objects, the parallel connected 3-phase breakers and the TACS objects for
flux measurement were compressed into single objects, and the icon of each group has been
customized, as well. The icon of some non-group objects were also customized, e.g. the LCC
object of the XLPE cable. The uncompressed version of this case is also part of the ATPDraw's
example collection and is shown in Fig. 6.42. Therefore, you can see how the grouping feature
makes the circuit more readable.
Fig. 6.42 - ATPDraw circuit without using compress (Exa_11.adp).
The model of the Ynd11 and the Dd0 transformers consists of a linear part (user specified library
object or BCTRAN object) and a nonlinear hysteretic inductor. The capacitances between the
transformer windings and ground have been considered, as well. These capacitances do not
influence the inrush current significantly, but they need to be taken into account especially at delta
coupled transformer terminals to avoid "floating subnetwork found" simulation errors. For more
details about the model parameters please read in section 5.8.2 of the Advanced Manual.
The compress option of ATPDraw can be used effectively to create new probe-type objects, as
well. The 3-phase Flux probe of this example is constructed by integrators (TACS | Transfer
functions | General) objects, time controlled switches (to set zero initial conditions) and coupling
to TACS objects. The output of the Flux probe (the instantaneous flux linkage of the transformer
windings) can be used to analyze the operation of the model during steady state no-load
conditions, and during the transformer de-energization/re-energization, as shown in Fig. 6.43.
The circuit breaker of the transformer has a common drive with mechanical phase shift of 60
electrical degrees. The making sequence is A-C-B with 3.33 ms delay between the poles and the
breaking sequence is B-C-A. Some results of the simulation obtained by the elaborated model are
shown next. Fig. 6.44 shows the flux linkage and the phase-to-ground voltages of the step-up
transformer during the no-load breaking process. The residual flux is quite low in all phases, thus
a subsequent energization will not produce high amplitude inrush current even if the making is
done at the voltage zero crossing. When synchronizing the first pole to close with the bus voltage
and energize the transformer close to the voltage peak, the inrush current amplitude will not
exceed the peak value of the nominal load current of the transformer (see in Fig. 6.45).
Application Manual
ATPDraw for Windows version 3.5 221
(file Exa_11.pl4; x-var c:TR15B -TR15C) t: FLX15C
-10 -5 0 5 10
-80
-60
-40
-20
0
20
40
60
80
Fig. 6.43 - Roaming of the operating point on the hysteresis loop in steady-state
and during the subsequent non-sinusoidal oscillations at transformer de-energization.
(file Exa_11.pl4; x-var t) v:TR132A v:TR132B v:TR132C
0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
[s]
-320
-240
-160
-80
0
80
160
240
320
[kV]
(file Exa_11.pl4; x-var t) t: FLX15A t: FLX15B t: FLX15C
0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
[s]
-80
-60
-40
-20
0
20
40
60
80
Fig. 6.44 - Non-sinusoidal voltage oscillations appear after de-energizing the step-up transformer
(upper curves). The residual flux is less then 30% in each phases (lower curves).
[Vs]
Amps
[Vs]
Application Manual
222 ATPDraw for Windows version 3.5
(fil e Exa_11.pl4; x-var t) c:BREKA -CABLA c:BREKB -CABLB c:BREKC -CABLC
10 15 20 25 30 35 40 45 50
[ms]
-10.0
-7.5
-5.0
-2.5
0.0
2.5
5.0
[A]
(fil e Exa_11.pl 4; x-var t) v:TR132A v:TR132B
0.16 0.17 0.18 0.19 0.20
[s ]
-150
-100
-50
0
50
100
150
[kV]
(fil e Exa_11.pl 4; x-var t) v:TR132A v:TR132B
0.17 0.18 0.19 0.20
[s ]
-160
-120
-80
-40
0
40
80
120
160
[kV]
(file Exa_11.pl4; x-var t) c:BREKA -CABLA c:BREKB -CABLB c:BREKC -CABLC
0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 0.24
[s ]
-2400
-1600
-800
0
800
1600
2400
3200
[A]
(file Exa_11.pl4; x-var t) c:BREKA -CABLA c:BREKB -CABLB c:BREKC -CABLC
0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 0.24
[s]
-500
-250
0
250
500
[A]
Fig. 6.45 - Interrupting the steady state no-load current of the step-up transformer (upper curves)
and the inrush current amplitude (below) when energizing the first pole of the breaker:
a) at the voltage zero crossing, b) close to the voltage peak.
Application Manual
ATPDraw for Windows version 3.5 223
6.9 Switching overvoltage studies with statistical approach (Exa_12.adp)
The switching impulse withstand level of EHV line insulators are generally lower than the
lightning impulse withstand level. Therefore, some measures are needed to protect the line against
switching overvoltages, especially when the insulation level is rather low, like in case of line
uprating. One or more of the following measures could be applied to reduce these overvoltages:
- mounting surge arresters at the line terminals and along the line
- application of circuit breaker with closing resistors
- synchronizing the breaker operations at line energization and reclosing
- limiting or eliminating the trapped charge at dead time of the 3-phase reclosing
The influence of the latter two measures to the switching overvoltage distribution is analyzed in
this example. The use of the master/slave feature of ATP's statistical switches is also introduced.
The EMTP model shown in Fig. 6.46 has been elaborated for a line upgrading feasibility study to
analyze the switching performance of a 400 kV compact line. The clearances, the location of the
phase- and ground wires, and the length of the composite insulator strings are assumed known in
this example.
Fig. 6.46 - ATPDraw circuit for the statistical switching study (Exa_12.adp).
The investigated line has been divided into four sections, each of them represented by an LCC
JMarti object. To set up the initial conditions of the line easily, a 3-phase voltage source is
connected to the line at right having voltage amplitude equal to the desired trapped charge. This
source is disconnected before the operation of the statistical switches to make the line unloaded. It
is worth to mention that some care is needed when constructing the EMTP model for such a
statistical simulations, because the unnecessary over-complication of the model may increase the
overall simulation time of that many statistical runs significantly.
6.9.1 Setting program options for the statistical simulation
The simulated switching incidence is a 3-phase reclosing in this study. Statistical switches of
Gaussian-type represent the reclosing breaker. The master/slave dependency is now supported by
ATPDraw, thus phase A is specified as master and the remaining two as slave. ATP requires the
master switch be specified earlier in the ATP-file then a slave. To ensure this ordering, the Group
No: of a master switch must be set lower than that of a slave, as shown in Fig. 6.47. Additionally,
the Sorting by group number option must also be activated on the ATP | Settings/Format page.
The above selections will result in data cards sorted in the ATP-file by class, then sorted by group
numbers in each classes.
Application Manual
224 ATPDraw for Windows version 3.5
Fig. 6.47 - Input parameters of master and slave statistical switches.
The rest of program options and circuit parameter settings for a statistical study is very similar to
that of any other time domain simulations. There is one addition however. You need to specify the
Switch study and Switch controls under ATP | Settings / Switch before generating the ATP-file.
Unless you need special settings, the Switch controls parameters need
not be modified. At the time of writing of this manual ATPDraw does
not write the BLANK STATISTICS request card at the end of the
ATP-file. In consequence of the missing request card, the statistical
evaluation results do not appear at the end of the LIS-file. To get this
valuable part of a statistical simulation, enter this request manually by
means of the Edit ATP-file feature as shown below, and run the
simulation with the corrected file by using the Run ATP (file) option.
I.e. do not use F2 command key to run the simulation.
.....
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BLANK STATISTICS
BEGIN NEW DATA CASE
BLANK
Fig. 6.48 - Setting the parameters of the statistical study.
6.9.2 Results of the statistical study
As worst-case assumption the fault, which precedes the 3-phase reclosing in one or more phases
has not been considered here. Taking that the inductive voltage transformers play a significant role
in eliminating the trapped charge in the healthy phases during the dead time of reclosing, but
CVTs or CCVT has no such effect, two different cases have been considered:
a1) the trapped charge is equal to the phase to ground voltage peak
a2) the trapped charge is 30% of the phase to ground voltage peak.
The reclosing operations are synchronized to the bus voltage in this simulation. It means that the
master switch is closed when the instantaneous value of the phase-to-ground bus voltage is equal
to zero. The average delay for the slave switches in phase B and C is set 120 and 60 electrical
Application Manual
ATPDraw for Windows version 3.5 225
degrees, respectively. The standard deviation of the operating time of the synchronous controller
and the breaker has been considered as an additional parameter in the study:
b1) accumulated deviation of the breaker and the controller operating time is 1 ms
b2) accumulated deviation of the breaker and the controller operating time is 2 ms.
The ATPDraw generated input file for the case a1) - b1) is shown below:
BEGIN NEW DATA CASE
C --------------------------------------------------------
C Generated by ATPDRAW July, Thursday 25, 2002
C A Bonneville Power Administration program
C Programmed by H. K. Hidalen at SEfAS - NORWAY 1994-2002
C --------------------------------------------------------
$DUMMY, XYZ000
C dT >< Tmax >< Xopt >< Copt >
1.E-5 .06
500 1 0 0 1 0 0 1 100
1 1 0 0 1 -1 0
C 1 2 3 4 5 6 7 8
C 345678901234567890123456789012345678901234567890123456789012345678901234567890
/BRANCH
C < n 1>< n 2><ref1><ref2>< R >< L >< C >
C < n 1>< n 2><ref1><ref2>< R >< A >< B ><Leng><><>0
X0078AX0076A 400. 0
X0078BX0076B 400. 0
X0078CX0076C 400. 0
X0074AX0072A 400. 0
X0074BX0072B 400. 0
X0074CX0072C 400. 0
-1X0068AX0001A 1. 700. 2.4E5 170. 1 0 0
-2X0068BX0001B .1 400. 2.8E5 170. 1 0 0
-3X0068CX0001C 0
-1X0072AX0001A 1. 700. 2.4E5 45. 1 0 0
-2X0072BX0001B .1 400. 2.8E5 45. 1 0 0
-3X0072CX0001C 0
X0070AX0068A 400. 0
X0070BX0068B 400. 0
X0070CX0068C 400. 0
X0074AX0072A 2. 50. 0
X0074BX0072B 2. 50. 0
X0074CX0072C 2. 50. 0
X0078AX0076A 5. 125. 0
X0078BX0076B 5. 125. 0
X0078CX0076C 5. 125. 0
X0070AX0068A 2. 65. 0
X0070BX0068B 2. 65. 0
X0070CX0068C 2. 65. 0
X0076AX0001A 5. 225. 0
X0076BX0001B 5. 225. 0
X0076CX0001C 5. 225. 0
92 ENDA 5555. 0
6.E5 -1. 1
531.55881849 20.203433531 0.52072093164
340.85559425 18.920649837 0.70833333333
217.84036322 16.914334208 0.8
266.23677718 19.220050355 0.91666666667
282.39443055 17.423190053 1.0333333333
662.1475865 10.787756369 1.1333333333
9999
92 ENDB ENDA 5555. 0
92 ENDC ENDA 5555. 0
X0032AX0033A 2. 100. 0
X0032BX0033B 2. 100. 0
X0032CX0033C 2. 100. 0
92 BEGA 5555. 0
6.E5 -1. 1
531.55881849 20.203433531 0.52072093164
340.85559425 18.920649837 0.70833333333
217.84036322 16.914334208 0.8
Application Manual
226 ATPDraw for Windows version 3.5
266.23677718 19.220050355 0.91666666667
282.39443055 17.423190053 1.0333333333
662.1475865 10.787756369 1.1333333333
9999
92 BEGB BEGA 5555. 0
92 BEGC BEGA 5555. 0
$INCLUDE, D:\ATPDRAW3\LCC\C_400.LIB, BEGA##, BEGB##, BEGC##, X0044A, X0044B $$
, X0044C
$INCLUDE, D:\ATPDRAW3\LCC\C_400.LIB, X0044A, X0044B, X0044C, MIDA##, MIDB## $$
, MIDC##
$INCLUDE, D:\ATPDRAW3\LCC\C_400.LIB, MIDA##, MIDB##, MIDC##, X0048A, X0048B $$
, X0048C
$INCLUDE, D:\ATPDRAW3\LCC\C_400.LIB, X0048A, X0048B, X0048C, ENDA##, ENDB## $$
, ENDC##
/SWITCH
C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP >< type >
ENDA X0032A -1. .001 0
ENDB X0032B -1. .01 0
ENDC X0032C -1. .01 0
X0001ABEGA .035 .001 STATISTICSTARGET 0
X0001BBEGB .00666 .001 STATISTICSX0001ABEGA 0
X0001CBEGC .00333 .001 STATISTICSX0001ABEGA 0
/STATISTICS
0 MIDA MIDB MIDC
/SOURCE
C < n 1><>< Ampl. >< Freq. ><Phase/T0>< A1 >< T1 >< TSTART >< TSTOP >
14X0078A 0 3.43E5 50. -1. 1.
14X0078B 0 3.43E5 50. -120. -1. 1.
14X0078C 0 3.43E5 50. 120. -1. 1.
14X0074A 0 3.43E5 50. -1. 1.
14X0074B 0 3.43E5 50. -120. -1. 1.
14X0074C 0 3.43E5 50. 120. -1. 1.
14X0070A 0 3.43E5 50. -1. 1.
14X0070B 0 3.43E5 50. -120. -1. 1.
14X0070C 0 3.43E5 50. 120. -1. 1.
14X0033A 0 3.43E5 50. -1. 1.
14X0033B 0 3.43E5 50. -120. -1. 1.
14X0033C 0 3.43E5 50. 120. -1. 1.
/INITIAL
/OUTPUT
MIDA MIDB MIDC
BLANK BRANCH
BLANK SWITCH
BLANK SOURCE
BLANK INITIAL
BLANK OUTPUT
BLANK PLOT
BLANK STATISTICS
BEGIN NEW DATA CASE
BLANK
Following the manual addition of the BLANK STATISTICS request card, the statistical
tabulation of the overvoltage distribution will be part of the LIS-file, as shown next:
1 ) --------------------------------------------------------------------------------------------------
Statistical output of node voltage 0.3430E+06 |0 MIDA MIDB MIDC
Statistical distribution of peak voltage at node "MIDA ".
The base voltage for per unit printout is V-base = 3.43000000E+05
Interval voltage voltage in Frequency Cumulative Per cent
number in per unit physical units (density) frequency .GE. current value
51 1.2750000 4.37325000E+05 0 0 100.000000
52 1.3000000 4.45900000E+05 2 2 98.000000
..........
87 2.1750000 7.46025000E+05 1 99 1.000000
88 2.2000000 7.54600000E+05 1 100 .000000
Summary of preceding table follows: Grouped data Ungrouped data
Mean = 1.66850000E+00 1.66882696E+00
Variance = 3.85116162E-02 3.81739314E-02
Standard deviation = 1.96243767E-01 1.95381502E-01
..........
4 ) --------------------------------------------------------------------------------------------------
SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY SUMMARY
4 ) --------------------------------------------------------------------------------------------------
The following is a distribution of peak overvoltages among all output nodes of the last data card that have
the same base voltage.
Application Manual
ATPDraw for Windows version 3.5 227
This distribution is for the maximum of the peaks at all output nodes with V-base = 3.43000000E+05
Interval voltage voltage in Frequency Cumulative Per cent
number in per unit physical units (density) frequency .GE. current value
51 1.2750000 4.37325000E+05 0 0 100.000000
52 1.3000000 4.45900000E+05 1 1 99.000000
............
91 2.2750000 7.80325000E+05 1 99 1.000000
92 2.3000000 7.88900000E+05 1 100 .000000
Summary of preceding table follows: Grouped data Ungrouped data
Mean = 1.77125000E+00 1.77305706E+00
Variance = 5.25173611E-02 5.27332819E-02
Standard deviation = 2.29166667E-01 2.29637283E-01
Finally, a brief summary of the simulation results is given next. Considering the metal-oxide
arresters with 2 p.u. protection level at both ends of the line, the highest overvoltages appear in the
inner points of the line. As an example, Fig. 6.49 shows the probability distribution functions of
the switching overvoltages arising in the middle of the line. The four curves correspond to the
following cases:
a) Three phase reclosing with 30% trapped charge. Standard deviation of the accumulated
operating time of the synchronous controller and the breaker is 1 ms.
b) Three phase reclosing with 100% trapped charge. Standard deviation of the accumulated
operating time of the synchronous controller and the breaker is 1 ms.
c) Three phase reclosing with 30% trapped charge. Standard deviation of the accumulated
operating time of the synchronous controller and the breaker is 2 ms.
d) Three phase reclosing with 100% trapped charge. Standard deviation of the accumulated
operating time of the synchronous controller and the breaker is 2 ms.
As it can be seen, the reclosing overvoltages are quite low even if the trapped charge is close to
the voltage peak, if the reclosing operations are synchronized to the bus-side voltage zero by a
point on wave controller.
0
10
20
30
40
50
60
70
80
90
100
1 1.2 1.4 1.6 1.8 2 2.2 2.4
P.U.
%
d1_t30%
d1_t100%
d2_t30%
d2_t100%
Fig. 6.49- Probability distribution function of the 3-phase reclosing overvoltages.
229
7. Appendix . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
ATPDraw
for Windows
3.5
Appendix
230 ATPDraw for Windows version 3.5
7.1 ATPDraw.ini file settings
The ATPDraw.ini file is optional and it is specified/edited under Tools | Options in ATPDraw.
At program startup, all optional program variables are given a default value. Then ATPDraw
searches the disk for an initialization file and if found, the new parameters are read from the file
into the optional variables, overriding the default values. If no such file is found, the default values
apply. ATPDraw will create/update the file on a Save or Load request under the Tools | Options
menu. The ATPDraw.ini file has 8 sections:
[ATPDraw] [Preferences] [Directories] [View Options]
[ATP Settings] [1024x768] [Reload] [Objects]
The ATPDraw.ini file is a standard Windows initialization file. Each section contains one or
more parameter = value lines. Empty lines or lines beginning with a semicolon (;) are ignored. The
following sections list and describe the name and legal value range of available parameters, as
well as the default settings (bold). One line is required for each parameter and at least one space is
needed between the parameter and any in-line comment string.
7.1.1 [ATPDraw]
The [ATPDraw] section contains information on the state and general behavior of ATPDraw.
These settings can be modified on the Tools | Options / General page as shown in Fig. 7.1.
Parameter Range Description
AutoSave On|Off Enables/disables circuit file auto saving.
AutoSaveInterval 1-60 [5] Specifies the autosave interval in number of minutes.
CreateBackupFile On|Off Enables/disables the creation of circuit backup files.
SaveWindowSizePos On|Off Enables/disables the storing of window size and position.
SaveWindowState On|Off Enables/disables the recording of main window current state
SaveToolbarState On|Off Enables/disables the recording of toolbar visibility state.
SaveStatusBarState On|Off Enables/disables the recording of status bar visibility state.
SaveCommentLineSt On|Off Enables/disables the circuit window comment line visibility.
Win31DialogStyle On|Off Enables/disables Windows 3.1 style open and save dialogs.
SaveOnExit On|Off Enables/disables the auto saving of program options on exit.
PolyDots On|Off Enables/disables the removal of extra points left on screen
by the polygon drawing function used to select groups of
objects in the circuit window.
PolyBug On|Off Enables/disables the use of an internal PolyLine function.
This is a workaround function that corrects a problem which
may appear with some display adapters when a polygon is
moved.
DeleteTempFiles On|Off Controls whether the user specified components are treated
as temporary files and deleted from the default directories at
program exit or not. Disabled from 3.5p7!
Note that the PolyDots and PolyBug options cannot be set from the Tools | Options dialog box. If
you experience problems during polygon drawing operations, try to set one or both parameters to
On using a text editor.
Appendix
ATPDraw for Windows version 3.5 231
Fig. 7.1 - General program options.
7.1.2 [Preferences]
The [Preferences] section contains information on undo, background color and the standard ATP
and ARMAFIT commands. The default settings can be modified on the Tools | Options /
Preferences page (Fig. 7.2).
Parameter Range Description
UndoBuffers 1-100 The number of undo/redo buffers to allocate for each circuit
[10] window.
BackgroundColor Circuit windows background color. You can specify one of
the system color identifiers or a numeric value to set the red,
green and blue color intensity.
TextEditor Full path of text editor program to use for ATP-file editing.
If this parameter is an empty string (default), the built-in text
editor is used.
ATPCommand The default command which executes the ATP
simulation.
ArmafitCommand The default command which executes the ARMAFIT
program.
7.1.3 [Directories]
This section contains information on the default directories for projects, ATP-files, and user-
generated components. These are the directories suggested by the Open and Save file dialogs in
ATPDraw initially. When a project is opened, ATPDraw will unzip the files on these directories if
the stored path does not exist. The user is free to store his components in any directory, however.
Parameter Range Description
Projects The folder name where you store the project files (.adp).
ATP Specifies the folder in which the ATP-files created (.atp).
Models Default folder for the MODELS definition (.mod) and
Appendix
232 ATPDraw for Windows version 3.5
support files (.sup).
Parameter Range Description
Group Container of the compressed GRP object support files (.sup).
UserSpecified The default folder of the DBM library (.lib) and support files
(.sup) for user specified components.
LineCables Container of the Line/Cable objects related files (.alc, .atp,
.lib, .lis, .pch).
Bctran The default folder for the BCTRAN transformer object
related files (.bct, .atp, .lis, .pch).
The default settings can be modified on the Tools | Options / Directories page (Fig. 7.3).
Fig. 7.2 - Specification of commands to execute external programs.
Appendix
ATPDraw for Windows version 3.5 233
Fig. 7.3- Default location of program folders.
7.1.4 [View Options]
These options control the default appearance of the circuit. The individual settings for the current
circuit can be specified under the View | Options menu. It is possible to select what to draw on the
screen by changing the check box status. The default view options for new projects can be
specified under the Tools | Options / View/ATP dialog as shown in Fig. 7.4.
Parameter Range Description
NodeNames On/Off Enables/disables the visibility of node names.
Labels On/Off Enables/disables the visibility of component labels.
Components On/Off Enables/disables the visibility of components.
Models On/Off Enables/disables the visibility of MODELS components.
Tacs On/Off Enables/disables the visibility of TACS components.
Connections On/Off Enables/disables the visibility of connection lines.
Relations On/Off Enables/disables the visibility of relation lines.
NodeDots On/Off Enables/disables the visibility of node dots (filled circles).
DragIcon On/Off Enables/disables complete icon drawing during single
component or selected group move operations.
NoDataWarning On/Off Enables/disables the visible warning of components and
nodes not opened and given meaningful data.
BranchOutOn=Off On/Off Enables/disables to show branch output (draw small symbols
to show branch output requests.
Fig. 7.4 - Setting view options for all new circuits.
7.1.5 [ATP Settings]
Specify the default value of ATP specific variables (initial miscellaneous data cards). The setting
for each individual circuit is found under the ATP | Settings menu. Of special importance is the
default time step, simulation length and power frequency. On the Output page printout control is
Appendix
234 ATPDraw for Windows version 3.5
set and Auto-detection of simulation errors can also be specified. The default values for new
projects can be modified on the View/ATP page of the Tools | Options menu as shown in Fig. 7.5.
Parameter Type Description
DeltaT Real Time step of simulation in seconds.
Tmax Real End time of simulation in seconds.
Xopt Real Inductances in [mH] if zero; otherwise, inductances in
[Ohm] with Xopt as frequency.
Copt Real Capacitances in [mF] if zero; otherwise, capacitances in
[Ohm] with Copt as frequency.
SysFreq Real System frequency in Hz.
IOut Integer Frequency of LUNIT6 output within the time-step loop. For
example, 3 means that every third time step will be printed.
IPlot Integer Frequency of saving solution points to the PL4 output file.
For example, a value of 2 means that every second time step
will be written to the PL4-file.
IDouble Integer If 1, table of connectivity written in the LUNIT6 output file.
If 0 (zero), no such table written.
KssOut Integer Controls steady state printout to the LUNIT6 output file.
MaxOut Integer If 1, extrema printed at the end of the LUNIT6 output file.
IPun Integer Flag that request additional card for the IOUT frequency.
MemSave Integer Controls the dumping of EMTP tables to disk at the end of
simulation if START AGAIN request is specified.
ICat Integer Controls saving of raw plot data points that is written to the
I/O channel LUNIT4. Possible values are:
Nenerg Integer Number of simulations. A value of 0 (zero) means single,
deterministic simulation; otherwise, statistic switch study.
ISW Integer If 1, printout of all variable switch closing/opening time to
LUNIT6.
ITEST Integer Extra random delay is added to all switch operations in
statistical studies.
IDIST Integer Select probability distribution of switch. 0 (zero) means
Gaussian and 1 means uniform distribution.
IMAX Integer If 1, printout of extrema to LUNIT6 for every energization.
IDICE Integer Use of standard random generator. A value of 0 (zero)
implies computer-dependent random generator and a value
of 1 standard random generator.
KSTOUT Integer Extra printed (LUNIT6) output for each energization.
NSEED Integer Repeatable MonteCarlo simulations.
HighResolution On/Off Usage of $Vintage 1 (if possible).
SortByCard On/Off Data file written with BRANCH cards first, followed by
SWITCH cards and the SOURCE cards.
SortByGroup On/Off The group number given to each object determines the
sequence of cards. The lowest group number comes first.
SortByXpos On/Off The leftmost object is written first.
AutoPath On/Off Library files are supposed to be located in the USP folder
and have the extension. When this option is enabled the
$Prefix, $Suffix option is written to the ATP-file.
AutoError On/Off Auto-detect LIS-file error messages.
Appendix
ATPDraw for Windows version 3.5 235
AutoErrorCode =0 Default errors to detect. Binary format: 1-2-4-8-16.
31 means, that all trigger string is active (1+2+4+8+16=31).
Fig. 7.5 - Setting ATP specific variables.
This section also includes a section for Commands (max 10) found under the ATP | Edit
Commands. Each command takes three lines. The first one specifies the command name that
appears in the menu, the second is the program/file to launch and the third is a code for what kind
of file to send as parameter.
Parameter Type Description
BatchJobx.name Text Name of the user specified commands. Number x specifies
the location of the commands in the ATP menu.
BatchJobx.filename Text Name of the batch (or .EXE) file executed by ATPDraw
when the command is selected in the ATP menu.
BatchJobx.parameter Integer Specifies which file is sent as parameter, before executing
the batch job: =0: No file name is sent, =1: File dialog opens
=2: ATP-file name is sent, =3: PL4-file name is sent.
Default settings for the Pocket Calculator features of ATP are also specified in the [ATP settings]
section:
Parameter Type Description
Var.Simulations =1 Number of Pocket Calculator simulations.
Var.Count =0 Number of $Parameter variables.
7.1.6 [1024x768]
This controls the default window position on the screen (Left, Top, Width, Height).
7.1.7 [Reload]
Contains the 5 last loaded project files. These files appear under the File | Reload menu.
7.1.8 [Objects]
This controls the visibility status of the Toolbar and the Status bar. Default setting makes them
visible at program startup, which can be modified in the View menu.
Appendix
236 ATPDraw for Windows version 3.5
7.2 PFC simulations in ATPDraw
The Verify feature of ATPDraw enables the user to compare the line/cable model with an exact PI-
equivalent as a function of frequency, or verify the power frequency benchmark data for
zero/positive short circuit impedances, reactive open circuit line charging, and mutual zero
sequence coupling. The Verify module supports the POWER FREQUENCY CALCULATION (PFC) of
zero and positive short circuit impedances and open circuit reactive line charging, along with
mutual zero sequence impedance for multi circuit lines.
The supporting programs LINE CONSTANTS and CABLE CONSTANTS calculate the series impedance
and the shunt admittance from geometrical data and material properties. These electrical
parameters are part of the printout file (.lis). The power frequency calculations give in principle
the short circuit impedances and the open circuit reactive power. The line/cable may be a single
circuit component with an arbitrary number of phases or a multi-circuit component where all
circuits normally are three-phase. The following parameters are calculated for a single circuit in a
line/cable with n conductors:
a) Short circuit impedances
All terminals at one end of the line/cable are connected to ground. A positive sequence
symmetrical voltage is applied to the terminals at the other end and the positive sequence
impedance is calculated:
+ + +
= I E Z /
The voltage applied to the terminal i is:
) / ) 1 ( 2 exp( n i j E E
i
- p - =
+
, where n is the number of phases in the circuit.
The positive sequence current is obtained from the terminal currents by the formula:
[ ] ) / 2 exp( ) / ) 1 ( 2 exp( ) / 2 exp(
1
2 1
n j I n i j I n j I I
n
I
n i
p - + + - p + + p + =
+
L L
The zero sequence impedance is calculated in a similar way:
0 0 0
/ I E Z =
The voltage E
0
here is applied to all terminals and I
0
is the average current supplied by the source.
b) Open-circuit reactive power
All terminals at one end of the component are open (except the conductors which are specified to
be grounded). A positive sequence symmetrical voltage is applied to the terminals at the other end
and the positive sequence current component is calculated by the same formula as for the positive
sequence impedance. The positive sequence open-circuit reactive power is then calculated by the
formula:
( )
*
Im
+ + +
= I E n Q , where E
+
is the line to line voltage.
Using the voltage between two adjacent phases for an n-phase circuit gives [ ] ) / sin( 2 / n V E p =
+
.
The calculation I
+
is based on an ATP calculation with E
+
=1.0. Using this value for I
+
implies
that
( )
+ +
p
-
= I
n
n V
Q Im
) / ( sin 4
2
2
ATP also automatically calculates the reactive power supplied by the source (Q
1
..Q
n
). The open-
circuit reactive power can thus also be calculated by taking the average of these quantities for all
phases and multiply by a factor 2 (since a peak value 1.0 is used in the calculation and the line-to-
line voltage is specified as rms):
Appendix
ATPDraw for Windows version 3.5 237
( )
n
Q Q Q
n
V
Q + + +
-
=
+
L
2 1
2
2
The zero sequence open-circuit reactive power is calculated as well. The same voltage is then
applied to all terminals at one end of the line. The zero sequence current is the average value of
the current injected into the terminals. This current I
0
is calculated by ATP with E
0
= 1.0. Using
this value for I
0
implies that
( )
0
2
2
0
Im
) / ( sin 4
I
n
n V
Q
p
-
=
In this case ATP automatically calculates the reactive power Q , injected into the circuit from the
source. Similarly to the positive sequence values, the zero sequence open-circuit reactive power is
also equal to
( ) Q
n
V
Q
2
2
0
-
=
For a line/cable with several circuits, each circuit is tested separately. For short-circuit calculation
the other circuit(s) is/are is also grounded at one end, while for open-circuit calculations all
terminals are open. The mutual coupling between the circuits is calculated as well and called zero
sequence transfer impedance. This is done by connecting all phases of each individual circuit to a
common node. A current 3I
0
is then applied to one of these common nodes circuit and the voltage
on the other node is measured. All terminals at the other end of the component is grounded. The
procedure is repeated for all circuits except the last one. Below is listed the xVerifyF.dat file
for a 6-phase line.
BEGIN NEW DATA CASE
1.667E-9 -1.0
1 1 1
$PREFIX, D:\ATPDraw3\lcc\
$INCLUDE, LCC_6.lib, INZO1_, INZO1_, INZO1_, INZO1D, INZO1E, INZO1F $$
, OUTO1A, OUTO1B, OUTO1C, OUTO1D, OUTO1E, OUTO1F
$INCLUDE, LCC_6.lib, INZO2A, INZO2B, INZO2C, INZO2_, INZO2_, INZO2_ $$
, OUTO2A, OUTO2B, OUTO2C, OUTO2D, OUTO2E, OUTO2F
$INCLUDE, LCC_6.lib, INZS1_, INZS1_, INZS1_, INZS1D, INZS1E, INZS1F $$
, ######, ######, ######, ######, ######, ######
$INCLUDE, LCC_6.lib, INZS2A, INZS2B, INZS2C, INZS2_, INZS2_, INZS2_ $$
, ######, ######, ######, ######, ######, ######
$INCLUDE, LCC_6.lib, INPO1A, INPO1B, INPO1C, INPO1D, INPO1E, INPO1F $$
, OUPO1A, OUPO1B, OUPO1C, OUPO1D, OUPO1E, OUPO1F
$INCLUDE, LCC_6.lib, INPO2A, INPO2B, INPO2C, INPO2D, INPO2E, INPO2F $$
, OUPO2A, OUPO2B, OUPO2C, OUPO2D, OUPO2E, OUPO2F
$INCLUDE, LCC_6.lib, INPS1A, INPS1B, INPS1C, INPS1D, INPS1E, INPS1F $$
, ######, ######, ######, ######, ######, ######
$INCLUDE, LCC_6.lib, INPS2A, INPS2B, INPS2C, INPS2D, INPS2E, INPS2F $$
, ######, ######, ######, ######, ######, ######
$INCLUDE, LCC_6.lib, INMS11, INMS11, INMS11, INMS12, INMS12, INMS12 $$
, ######, ######, ######, ######, ######, ######
BLANK BRANCH
BLANK SWITCH
14INZO1_+1 1.0 50. 0.0 -1.0
14INZO2_+1 1.0 50. 0.0 -1.0
14INPO1A+1 1.0 50. 0.0 -1.0
14INPO1B+1 1.0 50. -120. -1.0
14INPO1C+1 1.0 50. -240. -1.0
14INPO2D+1 1.0 50. 0.0 -1.0
14INPO2E+1 1.0 50. -120. -1.0
14INPO2F+1 1.0 50. -240. -1.0
14INZS1_+1 1.0 50. 0.0 -1.0
14INZS2_+1 1.0 50. 0.0 -1.0
14INPS1A+1 1.0 50. 0.0 -1.0
14INPS1B+1 1.0 50. -120. -1.0
14INPS1C+1 1.0 50. -240. -1.0
14INPS2D+1 1.0 50. 0.0 -1.0
Appendix
238 ATPDraw for Windows version 3.5
14INPS2E+1 1.0 50. -120. -1.0
14INPS2F+1 1.0 50. -240. -1.0
14INMS11-1 3. 50. 0.0 -1.0
BLANK SOURCE
INMS12
BLANK OUTPUT
BLANK CARD PLOT
BEGIN NEW DATA CASE
BLANK
The xVerifyF.dat file describes the following 9 cases:
Q1
1 V
coswt
1 V
coswt
Q2
1 V
coswt
I1
1 V
coswt
I2
+
+
3 I0
V12
I1A
I1B
I1C
I2D
I2E
I2F
+
+
Q1A
Q1B
Q1C
Q2D
Q2E
Q2F
Cir. 1:
1 Q
3
2
0
2
-
=
V
Q
Cir. 2:
2 Q
3
2
0
2
-
=
V
Q
Cir. 1:
1 I 3
1
0
= Z
Cir. 2:
2 I 3
1
0
= Z
Cir. 1:
120 120
C 1 I B 1 I A 1 I
3 0 . 1
j j
e e
Z
- +
+ +
= +
Cir. 2:
120 120
F 1 E 1 D 1
3 0 1
j j
e I e I I
.
Z
- +
+ +
= +
Cir. 1:
Q1C) Q1B (Q1A
3
2
2
+ +
-
= +
V
Q
Cir. 2:
Q2F) Q2E (Q2D
3
2
2
+ +
-
= +
V
Q
Cir. 1- Cir. 2:
V12/I0 00 = Z
E
+
=1.0 V
E
+
=1.0 V
E
+
=1.0 V
E
+
=1.0 V
Appendix
ATPDraw for Windows version 3.5 239
Zero sequence short circuit impedance: (real and imaginary part). Z
0
= R
0
+ jX
0
.
Each phase of a circuit is connected to a 1 V amplitude voltage source with zero phase angle. The
other end of the line is grounded. Z
0
is calculated as the inverse of the injected current divided by
the number of phases in the circuit. All phase conductors of other phases are open.
Positive sequence short circuit impedance: (real and imaginary part). Z
+
= R
+
+ jX
+
.
The phases of a circuit are connected to a 1 V amplitude voltage source with phase angle
-360*(i-1)/n where i is the phase number (1,2,3..) and n is the number of phases of the tested
circuit. The other end of the line is grounded. Z
+
is calculated as the inverse of the positive
sequence current. All phase conductors of other phases are open.
Zero sequence line charging: Q
0
Each phase of a circuit is connected to a 1 V amplitude voltage source with zero phase angle. The
other end of the line is open. Q
0
is the injected reactive power multiplied by the square of the user
specified base voltage (multiplied with 2/n). All phase conductors of other phases are open.
Positive sequence line charging: Q
+
The phases of a circuit are connected to a 1 V amplitude voltage source with phase angle
-360*(i-1)/n where i is the phase number and n is the number of phases of the tested circuit. The
other end of the line is open. Q
+
is calculated as the average injected reactive power multiplied by
the square of the user specified base voltage (multiplied with 2/n). All phase conductors of other
phases are open.
Mutual zero sequence impedance: (real and imaginary part). Z
00
= R
00
+ jX
00
.
Each phase of the i
th
circuit is connected to a 1 A amplitude current source with zero phase angle.
The receiving end of the circuits i and j is grounded. The j
th
circuit is short-circuited and open in
the sending end. Z
00
is calculated as the voltage at the sending end of the j
th
circuit. The process is
repeated for all circuits. All phase conductors of phases not belonging to the i
th
and j
th
circuit are
open.
Appendix
ATPDraw for Windows version 3.5 241
7.3 References
[1] ATPDRAW version 3, User Manual, TR A4389, EFI, Norway, 1996
[2] Ned Mohan, Computer Exercises for Power Electronic Education, 1990, Department of
Electrical Engineering, University of Minnesota.
[3] ATP-EMTP Rule Book, Canadian-American EMTP Users Group, 1997
[4] Lauren Dube, MODELS in ATP, Language manual, February 1996
[5] H.W. Dommel, Electromagnetic Transients Program. Reference Manual (EMTP Theory
Book), Bonneville Power Administration, Portland, 1986.
[6] L. Prikler, Main Characteristics of Plotting Programs for ATP, EEUG News Vol. 6,
No. 3-4, August-November 2000, pp. 28-33
Appendix
ATPDraw for Windows version 3.5 243
7.4 Index
$
$Include ......................................................99
$PARAMETER..................................75; 135
$Vintage .....................................................98
A
action mode ................................................44
ADF files ....................................................14
Alternative Transients Program..................10
licencing .................................................19
on-line licensing .....................................19
Armafit command.....................................138
ATP
ATP file ..................................................22
benchmark file......................................148
DBM-file ..............................................166
GNU version...........................................25
input file .................................................49
lib-file ...................................................136
punch-file..............................................136
Rule Book...............................................43
run ATP............................................24; 51
simulation...............................................49
Watcom version......................................25
ATP menu.............................................24; 70
ATP settings ...............................................70
ATPDraw......................................................9
ATPDraw.ini..............................23; 230
ATPDraw.scl......................................79
configuration ..........................................23
download ................................................20
examples...............................................177
hardware requirements ...........................20
include files ............................................22
installation ..............................................20
interface............................................23; 33
on-line help.............................................27
options ....................................................88
project file...............................................21
support file..............................................22
ATP-EMTP-L mailing list..........................27
attributes .....................................................38
Auto-detect errors.......................................71
auto-transformer .......................................214
B
BCTRAN...................................... 23; 115; 171
BCTRAN dialog...............................154; 214
BCTRAN file......................................22; 156
Bonneville Power Administration................9
C
CABLE CONSTANTS .............................23; 111
cable data page..........................................143
CABLE PARAMETERS .................................111
Canadian/American EMTP User Group
Tsu-huei Liu ...........................................10
W. Scott Meyer.......................................10
Characteristic tab........................................98
circuit comments ........................................34
circuit files..................................................59
circuit font ..................................................69
circuit window............................................34
Circuit window.....................................33; 34
C-like..........................................................13
command line options ................................26
comment dialog ..........................................65
comment line ..............................................68
Component selection menu ..... 33; 34; 37; 96
compress.............................. 64; 96; 129; 174
COMTRADE..............................................13
connections.................................................38
copy ............................................................62
copy graphics..............................................62
creating ATP-file........................................49
customizing objects ..................................166
cut ...............................................................62
D
Dahl Data Design .........................................9
DATA BASE MODULE ..................................23
DBM-file ..................................................167
DC machine..............................................160
default table size.........................................12
Default view options...................................91
delta T.........................................................50
Directories page..........................................91
distributed line..........................................110
download ....................................................20
Appendix
244 ATPDraw for Windows version 3.5
draw relation ................................ 35; 38; 123
duplicate............................................... 44; 62
E
edit ATP-file ................................ 51; 77; 224
Edit circuit............................ 65; 96; 132; 134
Edit commands .......................................... 78
edit component........................................... 79
Edit group ............................ 64; 96; 132; 134
Edit LIS-file ............................................... 77
Edit menu................................................... 37
edit operations............................................ 36
edit options................................................. 91
edit settings ................................................ 91
Electromagnetic Transients Program........... 9
EMTP......................................................... 10
applications ............................................ 15
Rule Book ............................................ 241
TPBIG.EXE........................................... 23
user group............................................... 19
enclosing pipe .......................................... 138
environmental variables
ATPDIR, WATDIR, GNUDIR.............. 25
export circuit .............................................. 60
external programs....................................... 24
extract........................................... 64; 96; 131
F
flux probe................................................. 220
Format page ............................................... 50
Fortran...................................................... 122
frequency components ............................. 124
G
generate ATP-file....................................... 78
gridsnap...................................................... 37
ground symbol ........................................... 49
group customization................................. 134
Group dialog ............................................ 102
group folder.............................................. 131
Group no. field........................................... 97
group selection........................................... 44
grouping................................... 129; 174; 183
GTPPLOT.................................................. 13
H
HARMONIC FREQUENCY SCAN.................... 29
Harmonic source ...................................... 165
Help editor ........................................... 82; 86
Help menu.................................................. 93
Help topics ................................................. 93
Hide button................................................. 98
hierarchical modeling................................... 9
Hridalen................................................. 9; 27
I
Icon editor ............................................ 81; 85
Import button ........................................... 157
import circuit.............................................. 60
Include characteristic ............................... 115
induction machine.................................... 160
initial conditions ................................ 10; 122
J
JMarti line................................................ 140
L
LCC object ....................................... 136; 190
library object .................................... 124; 184
LINE CONSTANTS ................................ 23; 111
line data settings....................................... 141
LINE MODEL FREQUENCY SCAN ............... 145
line/cable dialog............................... 111; 137
line/cable file.............................................. 22
linear branch............................................. 106
lines/cables....................................... 103; 109
Linux.......................................................... 13
LIS-file....................................................... 50
M
machines .................................................. 104
Main menu ........................................... 34; 58
Main window....................................... 33; 57
Make file .................................................... 38
Make File As.............................................. 49
Make names ......................................... 38; 78
Map window........................................ 34; 92
master/slave.............................................. 223
metafile .............................................. 61; 147
miscellaneous parameters .......................... 49
model file ................................................... 22
MODELS.....................10; 11; 104; 116; 148
input file structure................................ 117
model file ............................................. 149
mod-file.................................................. 84
new object ............................................ 150
record ..................................... 75; 154; 203
sup-file ................................................... 84
Type-94 mod-file ................................. 118
Use As field.......................................... 118
Appendix
ATPDraw for Windows version 3.5 245
MODELS language ..................................148
Modified flag..............................................49
mouse operations........................................36
move label ............................................35; 63
multi-layer circuit .....................................129
multilevel modeling..................................129
multiple simulations .................................136
N
new circuit ............................................39; 58
Noda line ..................................................140
Node attribute...........................................151
Node data window......................................36
Node dialog ..............................................100
nonlinear branch.......................................108
nonlinear characteristic...............................99
nonlinear transformer ...............................171
O
Objects menu..............................................38
Open group dialog......................................36
Open probe dialog ......................................38
open project ................................................58
Output combo box......................................47
Output request ............................................98
Output settings............................................71
P
Pacific Engineering Corporation..................9
paste............................................................62
PCPLOT.....................................................14
phase sequence ...........................................52
plotting programs .......................................13
PlotXY........................................................14
Pocket Calculator .....................................135
polygon selection........................................63
postprocessor ..............................................13
POWER FREQUENCY CALCULATION...145; 236
Power Quality Indexes................................13
Preferences page.........................................90
Probe Curr ..................................................41
Probe dialog..............................................102
Probe Volt...................................................42
probes & 3-phase......................................105
project file.............................................49; 59
public domain.............................................10
R
Record dialog .............................................74
redo.......................................................44; 61
reference object.................. 52; 106; 124; 184
refresh.........................................................68
relations ......................................................38
reload icon ..................................................60
request card.................................................74
rubber band...........................................63; 64
run ATP................................................49; 76
Run ATP button........................................138
running simulation......................................51
S
saturable transformer ................................159
save circuit..................................................49
save project .................................................59
selec group..................................................37
select group.................................................44
select object ................................................62
Semlyen line .............................................140
Shortcut menu.............................................96
simulation settings................................50; 70
Simulation sub-menu..................................49
single core cable .......................................138
SINTEF.........................................................9
sorting cards..........................................50; 73
sources ......................................................104
splitter.......................................................106
splitter object ..............................................53
standard components ............................28; 79
standard library.........................................125
statistical switch ...............................164; 223
Status bar ..............................................35; 67
support file..................................................79
supporting routine...............................11; 154
switches ....................................................103
synchronous machine ...............................160
SYSTRAN Engineering ...............................9
T
TACS........................................... 10; 11; 104
coupling to circuit.................................120
devices ..................................................121
transfer functions ..................................121
TACS menu..............................................120
Text editor ............................................77; 87
three-phase circuits.....................................52
toolbar...................................................45; 66
Tools menu.................................................85
TPPLOT .....................................................13
transformer inrush ....................................213
Appendix
246 ATPDraw for Windows version 3.5
transformers ..................................... 104; 115
transposition..................................... 106; 110
transposition object .................................... 52
trapezoidal rule .......................................... 10
U
undo ..................................................... 44; 61
universal machine .................... 114; 160; 180
untransposed ............................................ 110
user specified component............. 29; 79; 105
V
variables ............................................. 75; 135
Verify button............................................ 138
View options .............................................. 69
W
widenn PL4 ................................................ 13
WWW
www.eeug.org........................................ 20
www.emtp.org........................................ 19
Z
zoom........................................................... 68
Appendix
ATPDraw for Windows version 3.5 247