0% found this document useful (0 votes)
1K views9 pages

GPS Ter Clock Appendix E: Network Settings of GPS Using PC Windows As TELNET Client

This document provides instructions for configuring the network settings of a GPS master clock using a PC running Windows and Telnet. It details the default network settings, connecting the PC directly to the clock, and using Telnet commands to view and change the IP address, subnet mask, gateway, login name, and password. Commands include IP, MASK, GTY, U, P, H, ETH0, and QQ. The Telnet session times out after 5 minutes of inactivity.

Uploaded by

veeraboss
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views9 pages

GPS Ter Clock Appendix E: Network Settings of GPS Using PC Windows As TELNET Client

This document provides instructions for configuring the network settings of a GPS master clock using a PC running Windows and Telnet. It details the default network settings, connecting the PC directly to the clock, and using Telnet commands to view and change the IP address, subnet mask, gateway, login name, and password. Commands include IP, MASK, GTY, U, P, H, ETH0, and QQ. The Telnet session times out after 5 minutes of inactivity.

Uploaded by

veeraboss
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

GPS masTER CLOCK masibus

Model: MC-I Jan 25, 2011


Doc Ref No: m05/om/101-3 Issue No: 00


Page 1 of 9



GPS masTER CLOCK



Appendix E





Network Settings of GPS using PC Windows as
TELNET Client

















MASIBUS AUTOMATION & INSTRUMENTATION (P) LTD
B-30 GIDC, Electronics Estate, Gandhinagar 382044, Gujarat, India
Ph No: 91-79-23287275/76/77/78/79
Fax No: 91-79-23287281/82
Email: [email protected], [email protected]



GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 2 of 9
For the first time setup follow the below procedure:

1. Masibus GPS has following default network settings:
IP : 192.168.100.153
Subnet Mask : 255.255.255.000
Gateway : 192.168.100.001
First connect the GPS direct with local computer using a cross cable. (Not in
Network )

2. Make the computer IP 192.168.100.XXX (XXX is any value between 1 to 255)

3. Ping the GPS IP & response must come from GPS. Now follow the below
procedure.


Follow below procedure for GPS network settings using windows as
TELNET client.

1. Open command prompt.



2. Enter Telnet and press Enter.


GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 3 of 9
3. Enter open 192.168.100.153 and press Enter.



4. Following screen will be displayed.



5. Enter Loginname and press enter. Enter password and press enter. Loginname
and password both are case sensitive. Default Login name and password both
are masibus .

The Immortal Login name is masibus , which cannot be changed.

The Immortal Password is mc1, which cannot be changed.
GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 4 of 9











6. IP

This command is used to change IP address of GPS masTER CLOCK.
IP address should be entered in xxx.xxx.xxx.xxx form.
GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 5 of 9
Enter new IP address and press enter. To save the new IP address
Press Y else press N. If you press Y new IP address will be saved and if
you press N the previous IP address will be retained.
IP address of GPS masTER CLOCK is 192.168.100.153 by default.





7.. MASK

This command is used to change Subnet Mask of GPS masTER CLOCK.
Subnet Mask should be entered in xxx.xxx.xxx.xxx form.
Enter new Subnet Mask and press enter. To save the new Subnet Mask
Press Y else press N. If you press Y new Subnet Mask will be saved and if
you press N the previous Subnet Mask will be retained.
Subnet Mask of GPS masTER CLOCK is 255.255.255.0 by default.

GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 6 of 9



8.. GTY

This command is used to change Gateway of GPS masTER CLOCK.
Gateway should be entered in xxx.xxx.xxx.xxx form.
Enter new Gateway and press enter. To save the new Gateway
Press Y else press N. If you press Y new Gateway will be saved and if
you press N the previous Gateway will be retained.
Gateway of GPS masTER CLOCK is 192.168.100.1 by default.


GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 7 of 9

9. U

The user is allowed to change telnet Login name. The command for changing
the Login name is:
U.

Then enter new Login name and press enter. To save the new Login name
Press Y else press N. If you press Y new Login name will be saved and if
you press N the previous Login name will be retained.

The default Login name is masibus.

Remember that the Login name should not exceed 10 characters. If you try
to keep a Login name that has more than 10 characters, the system will
show an error Invalid Entry and the previous Login name will be retained.





10. P

The user is allowed to change telnet password. The command for changing
the password is:
P(password).

Then enter new password and press enter. To save the new password press
Y else press N. If you press Y new password will be saved and if you
press N the previous password will be retained.

The default password is masibus.

GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 8 of 9
Remember that the password should not exceed 10 characters. If you try
to keep a password that has more than 10 characters, the system will show
an error Invalid Entry and the previous password will be retained.



11.11 H

This HELP command is used to see different commands and their functions.







12. ETH0 ()[ETH0(zero)]

This command is used to see present Ethernet settings.

GPS masTER CLOCK masibus
Model: MC-I Jan 25, 2011
Doc Ref No: m05/om/101-3 Issue No: 00


Page 9 of 9


13. QQ

This command is used to close Telnet session.

14. Important Points:

GPS Telnet Server has timeout period of 5 minutes. If you do not press any
character till 5 minutes, the session will be automatically closed with a message of
Timeout, Session Closed.

NTP service will be stopped while Telnet session is opened. When you Logout
from the session or change IP address or after timeout the NTP service will be
automatically started.

Commands are case insensitive.

To set the network settings to default state,
i.e. IP Address : 192.168.100.153
Subnet Mask : 255.255.255.0
Gateway : 192.168.100.1
There is GPS master clock serial command ETH0. Enter this command through
serial com port2 of GPS master clock to set default Ethernet settings.