Date: 16 August 2012 Prepared by: EMC Data Management Team Principle: Edd Smith
Abstract:
This document outlines the management infrastructure for SMAS/Unishpere and Management Servers
Software Configuration Guide: Unisphere and EMC Management Servers
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 2 of 17
EMC 2 , IBM and Disney Confidential
This Document is the Confidential Information of EMC Corporation
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 3 of 17
EMC 2 , IBM and Disney Confidential
Revision Control This is a controlled document so that any and all changes must be approved by EMC Data Management Manager prior to implementation. Changes to this document and any supporting files under the control of this document can only be modified by EMC Data Management Team. Changes to the document or the guidelines may be requested by any affected application owner or business unit. To enact a change, the appropriate documents must follow the same change management processes as defined for software and hardware in accordance with any IBM change procedures. The document must be updated and presented as a draft to the IBM Managed Storage Operations team, as well as peer service providers and business units as appropriate, for approval. The new guidelines must include a verification step to make sure that the change will have the desired impact and not create any negative repercussions.
Revision History
Revision Number Date Author(s) Changes 1.0 12/01/11 Jeff Barrett Initial write 1.1 01/04/12 Guy Butch Updated management server list/added templates 1.2 03/29/2012 Edd Smith Updated Doc new map servers, personnel changes, improvements in process. 1.3 05/16/2012 Edd smith Added dis1sem005 1.4 08/16/2012 Edd Smith Kings Mountain and Various Updates 1.6 1/04/2013 Edd Smith Add Unisphere and VMAXKMT02-0900 2.0 1/05/2014 Edd Smith Format, naming, updates
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 4 of 17
EMC 2 , IBM and Disney Confidential
Table of Contents
Table of Contents ................................................................................................................................... 4 DIRECTORY OF TABLES .......................................................................................................................4 Document Overview ............................................................................................................................... 5 Intended Audience and Background ...................................................................................................... 5 Scope ...................................................................................................................................................... 5 Document Updates and Contacts........................................................................................................... 5 Procedural Updates.......................................................................................................................... 5 VMAX Management ............................................................................................................................... 8 Management Servers ............................................................................................................................. 8 Management Servers Specifications ...................................................................................................... 8 Management Server ............................................................................................................................... 9 UNIVMAX Server .................................................................................................................................... 9 Management Servers Drive Layout ...................................................................................................... 10 Management Server Software Installation .......................................................................................... 11 Management Server ............................................................................................................................. 11 UNIVMAX Server .................................................................................................................................. 11 UNIVMAX Configuration ....................................................................................................................... 12
Directory of Tables
Table 1: Revision Notes and Requests ........................................................................................................ 17
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 5 of 17
EMC 2 , IBM and Disney Confidential
Introduction Document Overview This document describes the software configuration to manage Unisphere for VMAX (UniVmax) and EMC Management Servers. This document is not intended to be a static document and will be subject to review and modification from time to time.
Intended Audience and Background There are two potential audiences for this documentation: Engineers and administrators providing the services for the IBM Managed Storage Operations Team Team Management and/or customers who need to review this documentation as a matter of course or to provide transparency/validation for Change Management and planning purposes
Scope This document covers the management software configuration for UNIVMAX and EMC Management Servers. This document publishes the configuration of the management infrastructure and documents hardware upgraded and configuration changes made to the UNIVMAX and EMC Management Servers.
Document Updates and Contacts
Procedural Updates IMPORTANT: The information contained in this document is current as of the date listed on the title page and the revision history contained on page 2.
Approver
Mark Schweitzer is the ultimate approver of this document.
If you wish to submit new or updated procedures for this document, use the procedural template defined in this document and save the document to the following location:
Please use the following naming convention for your procedural documentation:
This captures the organization, document subject, submission date, and document versions respectively. After submission, send a memo to the document reviewer and approver to notify them that a procedure is available for review.
Logging Procedural Notes
For notes or other procedural requests without a completed document, create an entry in the Error! eference source not found. section of this document.
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 7 of 17
EMC 2 , IBM and Disney Confidential
Overview of the UNISPHERE VMAX and Management Servers
This Configuration Guide is for UniVmax and EMC Management Servers in the Disney EIT environment. Each ECC agent Server and UniVmax server can manage up to two VMAX arrays.
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 8 of 17
EMC 2 , IBM and Disney Confidential
VMAX Management The table below lists the VMAX arrays by datacenter, plus which UNIVMAX and Management Servers are used for them.
Current Management Servers
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 9 of 17
EMC 2 , IBM and Disney Confidential
Management Server Specifications Management Server The EMC Data Management Team uses the Symcli/ECC agent (Gatekeeper Server) for ECC to communicate to the VMAX arrays. This server is also used for SYMCLI/Solutions Enabler commands. Communication to the array is through the SAN One management server will manage up to two VMAX arrays Server Specifications are: Following are the machine requirements for running UNIVMAX: Memory: 32GB CPUs: two (2) processors, 1.8GHz minimum Disk space: 160GB, assuming that all log settings are left at factory defaults Windows 64-bit operating system (2008 R2 recommended) 2 physical HBA SAN connectivity to the Symmetrix arrays 8 Gatekeepers (requires RDMs if the machine is a VM) These requirements are the same whether the machine is a VMware virtual machine or a physical server.
UNIVMAX Server The EMC Data Management Team uses the UNIVMAX server (SPA Server) for basic storage allocations, troubleshooting, and overall array management. Communication to the array is through the SAN One UNIVMAX server will manage up to two VMAX arrays Server Specifications are: Following are the machine requirements for running UNIVMAX: Memory: 32GB CPUs: two (2) processors, 1.8GHz minimum Disk space: 160GB, assuming that all log settings are left at factory defaults Windows 64-bit operating system (2008 R2 recommended) 2 physical HBA SAN connectivity to the Symmetrix arrays 8 Gatekeepers (requires RDMs if the machine is a VM) These requirements are the same whether the machine is a VMware virtual machine or a physical server.
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 10 of 17
EMC 2 , IBM and Disney Confidential
Management Servers Drive Layout
Drive layout # of SAN LUNs Volume Size (GB) Disk Type Intel Volume Label
Additional Info C:\ N/A 40G Internal Default Default Installation for Windows D:\ N/A ~105 (remainder of the drive) Internal Default Data E:\ 5 x 32GB (Legacy) or 5 x 34GB (FAST VP) 160 SAN Tier 1.5 Silver Policy for FAST VP VMAX Data Data
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 11 of 17
EMC 2 , IBM and Disney Confidential
Management Server Software Installation Management Server Solutions Enabler 32bit will be installed on the D: drive o Version 7.3.2 o Add D:\Program Files\EMC\SYMCLI\bin or the similar path for the binary file location and type of Solutions Enabler that was installed to the Windows system PATH variable The latest version of Cygwin will be installed on the D: drive. Working and script directories will be on the E: drive o The E: drive should be used for all downloads and outputs o Create a ~EMC Data Management Team directory for this ECC Agents will be installed on the D: drve o Master agent o Host agent o Symmetrix agent o SDM agent All DMT staff need Administrator rights to the server o WDW accounts
UNIVMAX Server Solutions Enabler 64bit will be installed on the D: drive o Version 7.3.2 UNIVMAX 64bit will be installed on the E: drive o Version 7.3.3 Working and script directories will be on the E: drive o The E: drive should be used for all downloads and outputs o Create a ~EMC Data Management Team directory for this ECC Agents will be installed using the defaults o Master agent o Host agent All EDMT VMAX staff need Administrator rights to the server o WDW accounts will be used
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 12 of 17
EMC 2 , IBM and Disney Confidential
UNIVMAX Configuration SMC Software configuration: FAST VP Arrays Default allocation templates will be built Template 1- {34GB_Device} o All FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 37138 Cyl (34GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 2- {68GB_Meta_Device} o All FAST VP Arrays available to the UNIVMAX Server o Devices Find Existing o Device configuration TDEV o Emulation FBA o Capacity for each device 37138 Cyl (34GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % o Meta Yes o Meta member count (including head) 2 o Meta configuration Striped Template 3- {100GB_Device} o All FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 13 of 17
EMC 2 , IBM and Disney Confidential
o Emulation FBA o Capacity for each device 109227 Cyl (100GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 4- {VMware_1TB_Meta_Device} o All FAST VP Arrays available to the UNIVMAX Server o Devices Find Existing o Device configuration TDEV o Emulation FBA o Capacity for each device 109227 Cyl (100GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % o Meta Yes o Meta member count (including head) 10 o Meta configuration Striped DREAMS FAST VP Arrays Default allocation templates will be built Template 1- {DREAMS_32GB_Device} o All FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 34953 Cyl (32GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 %
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 14 of 17
EMC 2 , IBM and Disney Confidential
Legacy Standard/VP Arrays (Non-FAST VP) Template 1- {2GB_Quorum_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 2185 Cyl (2GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 2- {32GB_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 34953 Cyl (32GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 3- {64GB_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 69906 Cyl (64GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 4-{100GB_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices create
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 15 of 17
EMC 2 , IBM and Disney Confidential
o Device configuration TDEV o Emulation FBA o Capacity for each device 109227 Cyl (100GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 5- { SAP_256GB_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices create o Device configuration TDEV o Emulation FBA o Capacity for each device 34953 Cyl (32GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % Template 6- {VMware_1TB_Meta_Device} o All non-FAST VP Arrays available to the UNIVMAX Server o Devices Find Existing o Device configuration TDEV o Emulation FBA o Capacity for each device 109227 Cyl (100GB) o RDF None o Persistent preallocation Persist preallocated capacity through reclaim or copy Not selected o Preallocate per device 100 % o Meta Yes o Meta member count (including head) 10 o Meta configuration Striped
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers
Copyright 2010 EMC Corporation Page 16 of 17
EMC 2 , IBM and Disney Confidential
Default alerts will be Alert 1-{Name Here} : This alert will notify DMT team when .. o Config Variables o Config Variables o Config Variables Alert 2-{Name Here} : This alert will notify DMT team when .. o Config Variables o Config Variables o Config Variables
Security/Authentication: o Authentication will be done ONLY through the WDW domain o Sean Rouse, Edd Smith, Praveen Attelli, and Jeff Barrett will have Admin rights o All other EDMT members will have Storage Admin rights o SMC Password will be changed to a secure SMC password o Site Architect and Tool Administrator have the Password and will change on first login
Request/Update Description Requestor Date
EMC Program Delivery for Disney Software Configuration Guide: Unisphere and EMC Management Servers