Module 4: Worked Out Problems
Module 4: Worked Out Problems
Problem 1:
Find: temperature at the midpoint using the exact solution considering the first five
nonzero terms: Assess the error from using only the first three terms.
Schematic:
∞
T − T1 2 ( −1) n +1 + 1 nπ x sinh( nπ y / L )
θ ( x, y ) = =
T2 − T1 π ∑
n =1
n
sin .
L sinh( nπ W / L )
Considering now the point (x, y) = (1.0, 0.5) and recognizing x/L =1/2, y/L=1/4 and
W/L=1/2, the distribution has the form
∞
T − T1 2 (−1) n +1 + 1 nπ sinh( nπ / L)
θ (1,0.5) = =
T2 − T1 π ∑n =1
n
sin .
L sinh( nπ / L)
When n is even (2,4,6…..), the corresponding term is zero; hence we need only
consider n=1,3,5,7 and 9 as the first five non-zero terms.
⎧ π 3π 5π ⎫
sinh sinh sinh
⎪ π
⎛ ⎞ π
4 + sin ⎛⎜ ⎞⎟
2 3 4 + sin⎛⎜ ⎞⎟
2 5π 4 +⎪
⎪2 sin⎜ ⎟ ⎪
⎪ ⎝ 2 ⎠ sinh π 3 ⎝ 2 ⎠ sinh 3π 5 ⎝ 2 ⎠ sinh 5π ⎪
2⎪
θ (1,0.5) = ⎨ 2 2 2 ⎪
⎬
π⎪ 7π 9π ⎪
sinh sinh
⎪ 2 ⎛ 7π ⎞ 4 + 2 sin⎛⎜ 9π ⎞⎟ 4 ⎪
sin⎜ ⎟
⎪ 7 ⎝ 2 ⎠ sinh 7π 9 ⎝ 2 ⎠ sinh π ⎪ 9
⎪ ⎪
⎩ 2 2 ⎭
2
θ (1,0.5) = [0.755 + 0.063 + 0.008 − 0.001 + 0.000] = 0.445
π
If only the first term of the series, Eq (2) is considered, the result will be θ(1, 0.5)
=0.446 that is, there is less than a 0.2% effect.
Problem 2:
A long power transmission cable is buried at a depth (ground to cable centerline distance)
of 2m. The cable is encased in a thin walled pipe of 0.1 m diameter, and to render the
cable superconducting (essentially zero power dissipation), the space between the cable
and pipe is filled with liquid nitrogen at 77 K. If the pipe is covered a super
insulator(ki=0.005W/m.K) of 0.05-m thickness and the surface of the earth
(kg=1.2W/m.K) is at 300K, what is the cooling load in W/m which must be maintained
by a cryogenic refrigerator per unit pipe length.
Schematic:
Tg=300K
Kg=1.2W/m.K
Insulation, ki=0.005W/m.K,
Z=2m Do=0.2m,Di=0.1m
Liquid nitrogen.Tn=77K
Cable
T g − Tn
q' =
R g' + R I'
T g − Tn
q' =
[k g (2π / ln(4 z / Do ))] −1 + ln( Do / Di ) / 2π k i
where table 4.1 have been used to evaluate the ground resistance. Hence,
(300 − 77) K
q' =
[(1.2W / m.K ) (2π / ln(8 / 0.2))] −1 + ln(2) / 2π × 0.005 W / m.K
223K
q' =
(0.489 + 22.064)m.K / W
q ' = 9.9W / m
Comments: the heat gain is small and the dominant contribution to the thermal resistance
is made by the insulation.
Problem 3:
Two parallel pipelines spaced 0.5 m apart are buried in soil having a thermal conductivity
of 0.5W/m.K. the pipes have outer-diameters of 100 and 75 mm with surface
temperatures of 175°C and 5°C, respectively. Estimate the heat transfer rate per unit
length between the two pipe lines.
Find: heat transfer per unit length between the pipe lines.
Schematic:
Assumptions: (1) steady state conditions, (2) two-dimensional conduction, (3) constant
properties, (4) pipe lines are buried very deeply approximating burial in an infinite
medium, (5) pipe length>> D1 or D2 and w>D1 or D2
Analysis: the heat transfer rate per length from the hot pipe to the cool pipe is
q S
q' = = k (T1 − T2 )
L L
2πL
S=
⎛ 4 w 2 − D12 − D 22 ⎞
cosh −1 ⎜ ⎟
⎜ 2 D1 D 2 ⎟
⎝ ⎠
Known: Cubical furnace, 350mm external dimensions, with 50mm thick walls.
Schematic:
−
Properties: From table of properties, fireclay brick ( T = (T1 + T2 ) / 2 = 610 K ) : k ≈ 1.1W / m.K
Analysis: using relations for the shape factor from table 4.1,
A 0.25 × 0.25m 2
Plane walls (6) SW = = = 1.25m
L 0.05m
W
q = 1.1 (6 × 1.25m + 12 × 0.14m + 0.15 × 0.008m)(600 − 75)°C
m.K
q = 5.30kW
Comments: Be sure to note that the restriction for SE and SC has been met.
Problem 5:
Consider nodal configuration 4 of table 4.2. Derive the finite-difference equation under
steady-state conditions for the following situations.
(a) The upper boundary of the external corner is perfectly insulated and the side boundary
is subjected to the convection process (T∞, h)
(b) Both boundaries of external corner are perfectly insulated.
Find: finite-difference equations for these situations: (a) upper boundary is perfectly
insulated and side boundary is subjected to a convection process, (b) both boundaries are
perfectly insulated.
Schematic:
Analysis: Consider the nodal point configuration shown in schematic and also as case
4, table 4.2. the control volume about the nodes shaded area above of unit thickness
normal to the page has dimensions, (Δx/2)( Δy/2).1. The heat transfer processes at the
surface of the CV are identified as q1, q2….perform an energy balance wherein the
processes are expressed using the appropriate rate equations.
With the upper boundary insulated and the side boundary and the side boundary subjected
to a convection process, the energy balance has the form
.
E in − E out = 0 q1 + q 2 + q 3 + q 4 = 0
⎛ Δy ⎞ Tm −1, n − Tm, n ⎛ Δx ⎞ Tm, n −1 − Tm, n ⎛ Δy ⎞
k⎜ .1⎟ + k⎜ . 1⎟ + h⎜ .1⎟ (T∞ − Tm, n ) + 0 = 0
⎝ 2 ⎠ Δx ⎝ 2 ⎠ Δy ⎝ 2 ⎠
Letting Δx=Δy, and regrouping, find
hΔx ⎛ 1 hΔx ⎞
Tm, n −1 + Tm −1, n + T∞ − 2⎜ + 1⎟Tm, n = 0
k ⎝2 k ⎠
with both boundaries insulated, the energy balance of Eq(2) would have q3=q4=0. the
same result would be obtained by letting h=0 in the finite difference equation, Eq(3). The
result is
Comments: Note the convenience resulting formulating the energy balance by assuming
that all the heat flow is into the node.