100% found this document useful (1 vote)
557 views3 pages

EC2 Beam Section Design

This document provides details of the design calculations for a reinforced concrete beam with a rectangular cross-section. Key details include: - The beam has a width of 300mm and depth of 500mm with C40/50 concrete. - Two 25mm diameter tension reinforcement bars are provided, which do not meet the minimum area requirement. - Shear reinforcement of 2 x 8mm bars at 300mm centres is provided, meeting code requirements. - Crack control and serviceability checks are also performed and pass requirements. - The beam design fails to meet flexural requirements due to insufficient tension reinforcement area.

Uploaded by

ikanyu79
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
557 views3 pages

EC2 Beam Section Design

This document provides details of the design calculations for a reinforced concrete beam with a rectangular cross-section. Key details include: - The beam has a width of 300mm and depth of 500mm with C40/50 concrete. - Two 25mm diameter tension reinforcement bars are provided, which do not meet the minimum area requirement. - Shear reinforcement of 2 x 8mm bars at 300mm centres is provided, meeting code requirements. - Crack control and serviceability checks are also performed and pass requirements. - The beam design fails to meet flexural requirements due to insufficient tension reinforcement area.

Uploaded by

ikanyu79
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Project

J ob Ref.

Section

Sheet no./rev.
1
Calc. by
P
Date
9/10/2014
Chk'd by

Date

App'd by

Date



RC BEAM DESIGN ONLY (EN1992)
RC BEAM DESIGN (EN1992-1)
In accordance with Singapore national annex
TEDDS calculation version 2.1.15
Rectangular section details
Section width; b =300 mm
Section depth; h =500 mm
Concrete details (Table 3.1 - Strength and deformation characteristics for concrete)
Concrete strength class; C40/50
Characteristic compressive cylinder strength; fck =40 N/mm
2

Characteristic compressive cube strength; fck,cube =50 N/mm
2

Mean value of compressive cylinder strength; fcm =fck +8 N/mm
2
=48 N/mm
2

Mean value of axial tensile strength; fctm =0.3 N/mm
2
(fck/ 1 N/mm
2
)
2/3
=3.5 N/mm
2

Secant modulus of elasticity of concrete; Ecm =22 kN/mm
2
[fcm/10 N/mm
2
]
0.3
=35220 N/mm
2

Partial factor for concrete (Table 2.1N); C =1.50
Compressive strength coefficient (cl.3.1.6(1)); cc =0.85
Design compressive concrete strength (exp.3.15); fcd =cc fck / C =22.7 N/mm
2

Maximum aggregate size; hagg =20 mm
Reinforcement details
Characteristic yield strength of reinforcement; fyk =500 N/mm
2

Partial factor for reinforcing steel (Table 2.1N); S =1.15
Design yield strength of reinforcement; fyd =fyk / S =435 N/mm
2

Nominal cover to reinforcement
Nominal cover to top reinforcement; cnom_t =35 mm
Nominal cover to bottom reinforcement; cnom_b =35 mm
Nominal cover to side reinforcement; cnom_s =35 mm

5
0
0


Rectangular section in flexure (Section 6.1) - Positive midspan moment
Design bending moment; M =300 kNm
Depth to tension reinforcement; d =h - cnom_b - v - bot / 2 =445 mm
Percentage redistribution; mr =0 %
Redistribution ratio; =min(1 - mr, 1) =1.000
K =M / (b d
2
fck) =0.127
K' =0.598 - 0.181
2
- 0.21 =0.207
Project

J ob Ref.

Section

Sheet no./rev.
2
Calc. by
P
Date
9/10/2014
Chk'd by

Date

App'd by

Date



K' > K - No compression reinforcement is required
Lever arm; z =min((d / 2) [1 +(1 - 3.53 K)
0.5
], 0.95 d) =388 mm
Depth of neutral axis; x =2.5 (d - z) =142 mm
Area of tension reinforcement required; As,req =M / (fyd z) =1780 mm
2

Tension reinforcement provided; 2 25 bars
Area of tension reinforcement provided; As,prov =982 mm
2

Minimum area of reinforcement (exp.9.1N); As,min =max(0.26 fctm / fyk, 0.0013) b d =243 mm
2

Maximum area of reinforcement (cl.9.2.1.1(3)); As,max =0.04 b h =6000 mm
2

FAIL - Area of reinforcement provided is less than area of reinforcement required
Rectangular section in shear (Section 6.2)
Design shear force at span s1; VEd,max =abs(max(Vs1_max, Vs1_red)) =100 kN
Angle of comp. shear strut for maximum shear; max =45 deg
Maximum design shear force (exp.6.9); VRd,max =b z v1 fcd / (cot(max) +tan(max)) =664 kN
PASS - Design shear force at support is less than maximum design shear force
Design shear force ; VEd =100 kN
Design shear stress; vEd =VEd / (b z) =0.860 N/mm
2

Strength reduction factor (cl.6.2.3(3)); v1 =0.6 [1 - fck / 250 N/mm
2
] =0.504
Compression chord coefficient (cl.6.2.3(3)); cw =1.00
Angle of concrete compression strut (cl.6.2.3);
=min(max(0.5 Asin[min(2 vEd / (cw fcd v1),1)], 21.8 deg), 45deg) =21.8 deg
Area of shear reinforcement required (exp.6.13); Asv,req =vEd b / (fyd cot()) =237 mm
2
/m
Shear reinforcement provided; 2 8 legs at 300 c/c
Area of shear reinforcement provided; Asv,prov =335 mm
2
/m
Minimum area of shear reinforcement (exp.9.5N); Asv,min =0.08 N/mm
2
b (fck / 1 N/mm
2
)
0.5
/ fyk =304 mm
2
/m
PASS - Area of shear reinforcement provided exceeds minimum required
Maximum longitudinal spacing (exp.9.6N); svl,max =0.75 d =333 mm
PASS - Longitudinal spacing of shear reinforcement provided is less than maximum
Crack control (Section 7.3)
Maximum crack width; wk =0.3 mm
Design value modulus of elasticity reinf (3.2.7(4)); Es =200000 N/mm
2

Mean value of concrete tensile strength; fct,eff =fctm =3.5 N/mm
2

Stress distribution coefficient; kc =0.4
Non-uniform self-equilibrating stress coefficient; k =min(max(1 +(300 mm - min(h, b)) 0.35 / 500 mm, 0.65), 1) =1.00
Actual tension bar spacing; sbar =(b - 2 (cnom_s +v) - bot) / (Nbot - 1) =189 mm
Maximum stress permitted (Table 7.3N); s =249 N/mm
2

Concrete to steel modulus of elast. ratio; cr =Es / Ecm =5.68
Distance of the Elastic NA from bottom of beam; y =(b h
2
/ 2 +As,prov (cr - 1) (h - d)) / (b h +As,prov (cr - 1)) =
244 mm
Area of concrete in the tensile zone; Act =b y =73266 mm
2

Minimum area of reinforcement required (exp.7.1); Asc,min =kc k fct,eff Act / s =413 mm
2

PASS - Area of tension reinforcement provided exceeds minimum required for crack control
Quasi-permanent limit state moment; MQP =80 kNm
Permanent load ratio; RPL =MQP / M =0.27
Service stress in reinforcement; sr =fyd As,req / As,prov RPL =210 N/mm
2

Maximum bar spacing (Tables 7.3N); sbar,max =200 mm
PASS - Maximum bar spacing exceeds actual bar spacing for crack control
Project

J ob Ref.

Section

Sheet no./rev.
3
Calc. by
P
Date
9/10/2014
Chk'd by

Date

App'd by

Date



Minimum bar spacing
Minimum bottom bar spacing; sbot,min =(b - 2 cnom_s - 2 v - bot) / (Nbot - 1) =189 mm
Minimum allowable bottom bar spacing; sbar_bot,min =max(bot, hagg +5 mm, 20 mm) +bot =50 mm
Minimum top bar spacing; stop,min =(b - 2 cnom_s - 2 v - top) / (Ntop - 1) =202 mm
Minimum allowable top bar spacing; sbar_top,min =max(top, hagg +5 mm, 20 mm) +top =37 mm
PASS - Actual bar spacing exceeds minimum allowable

You might also like