Metrel 2014

Download as pdf or txt
Download as pdf or txt
You are on page 1of 117

CATALOGUE 2014

Electrical Installation Safety


High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
MEASURING INSTRUMENTS AND TESTERS
w
w
w
.
m
e
t
r
e
l
.
s
i
M
e
t
r
e
l


d
.
d
.
;

L
j
u
b
l
j
a
n
s
k
a

c
.

7
7
;

S
l

-
1
3
5
4

H
o
r
j
u
l
;

S
l
o
v
e
n
i
a
3 2
Measuring and Regulation Equipment
METREL d.d.
Ljubljanska c. 77
SI-1354 Horjul
Tel: +386 (0)1 7558 200
E-mail: metrelmetrel.si
www.metrel.si
Mess und Prftechnik
Metrel GmbH
Orchideenstrae 24
90542 Eckental
Tel.: +49 (0) 9126 28996-0
E-mail: metrelmetrel.de
www.metrel.de
Test and Measuring Equipment
Metrel UK
Unit 1, Hopton House, Ripley Drive,
Normanton, West Yorkshire, WF6 1QT
Tel.: +44 (0) 1924 245 000
E-mail: infometrel.co.uk
www.metrel.co.uk
Measuring and Regulation Equipment Manufacturer
GERMAN market
UK market
GLOBAL market
Metrel - Measuring and Regulation Equipment Manufacturer
Metrel is an international Group and an
expert in the research, development
and production of test and measure-
ment equipment. Metrel brand name is
worldwide recognized and associated
with high quality test and measurement
products.
Metrels instruments provide test and
measurement solutions in different
maintenance areas including the safety
testing of electrical installations and ap-
pliances, power quality analysis, local
area network analysis and the meas-
urement of indoor environmental con-
ditions. In short, our products help to
provide information about the safety and
functionality of different installations and
environments. Through innovative de-
sign, electronics and software solutions
we provide accurate, reliable and safe to
use products.
The company strives to be the leader
in advanced technological solutions and
therefore invests over 10 % of the yearly
turnover into the R&D department.
Our wide range of products is backed up
with a complete support package includ-
ing repair and calibration, technical sup-
port and customer training programs. A
detailed calibration certicate is supplied
as standard with all Metrel products.
SALES NETWORK
Metrels products are sold and serviced
in over 80 countries by local agents and
distributors. Our associated companies
are managed by local people who know
the special needs of their markets. Sales
engineers and specially trained techni-
cians staff give excellent service to our
customers.
The GERMAN market is supported by
Metrel GmbH based in Eckental (www.
metrel.de) and the UK market is support-
ed by Metrel UK based in Normanton
(www.metrel.co.uk). Inquiries for other
countries please direct to Metrel d.d.,
the headquarters based in SLOVENIA
(www.metrel.si).
COMMITMENT TO QUALITY
Metrels quality assurance system is
based on BS EN ISO 9001. Through
permanent training and education of our
employees we strive to increase the ef-
ciency and quality of all our processes.
Our commitment to quality is recognized
by our customers and is ensured by con-
tinuous and extensive research and de-
velopment of new, accurate, reliable and
safe to use products.
ECOLOGY
Metrel test and measurement equip-
ment complies to the RoHS and WEEE
directives. Metrel strives to meet its
goals with the most efcient use of re-
sources and the least possible impact on
the environment.
RESEARCH, DEVELOPMENT AND
PRODUCTION
The research, development and pro-
duction of Metrels products are based
in Europe (Slovenia) at Metrel d.d. The
company strives for total quality control.
A dedicated quality assurance depart-
ment ensures strict adherence to cus-
tomer specications. Highly competent
R&D engineers provide advanced solu-
tions for our customers.
TEST LABORATORY
The highly professional test laboratory
based in Metrel d.d. provides internal
services including the testing of compo-
nents, subassemblies and prototypes of
products. This enables Metrel to launch
safe and reliable new products into the
market. The laboratory provides testing
according to the Low Voltage Directive
(2006/95/EC) and the EMC Directive
(2004/108/EC). The main standards that
Metrel also complies to include IEC/EN
61010 and IEC/EN 61326.
PRODUCTS
Metrel is producing test and measure-
ment equipment that is covering the fol-
lowing elds:
Electrical Installations Safety Testing
(IEC/EN 61557, VDE 0413, VDE 0100,
BS 7671, HD 60364, CEI 64.8, AS/NZS
3017, AS/NZS3760).
Portable Appliances, Machines and
Switchgears Safety Testing (IEC/EN
60204-1, IEC/EN 61439-1, IEC/EN
60335-1, VDE 0701-0702).
Measurement and Testing of Cable
Networks (TIA/EIA-568-B, ISO 11801,
EN 50173, EN 50346, IEC/EN 61935).
Testing of Power Distribution Sys-
tems and Power Quality Analysis
(EN 50160).
Analysis of Indoor Environment
Quality (DIN 5032, IEC/EN 60584-1,
EN 12599, EN ISO 7726, ISO 11664).
Equipment for Laboratories and
Schools: Metrel produces a variety
of instruments for electrical testing
laboratories and educational purposes.
Typical application areas are: electri-
cal workshops, testing labs, research,
development and education. The main
products Metrel produces include
demo boards, power supply units, R-
L-C decades.
Transformers: Metrel produces two
kinds of toroidal transformers: variable
transformers (according to standard
EN60989) and power transformers
(according to standard EN 61558).
Besides the test and measurement
product portfolio offered by Metrel d.d.
Metrels daughter company Metrel Me-
hanika d.o.o. also provide a variety of
products focusing on metal process-
ing. Their core business is sheet metal
production, milled / turned production,
manufacturing of tools and surface pro-
tection. For more information please
visit www.metrel-mehanika.si.
5 4
Instruments Designed with Future in Mind Metrel - Measuring and Regulation Equipment Manufacturer
SERVICES
Metrel provides a variety of services re-
lating to training, repair and calibration of
test equipment to the highest standards
in the industry.
REPAIR
Metrel provides fast and efcient repair
services either directly at Metrels head
quarters service centre or through ap-
proved business partners.
CALIBRATION
The Calibration Laboratory at Metrel DUS
is able to calibrate electronic measuring
instruments and devices in compliance
with the requirements of the ISO/IEC
17025 standard. The laboratory is ac-
credited by Slovenian Accreditation (SA),
a member of European Accreditation
(EA), signatory of the Multilateral Agree-
ments for the European Co-operation
for Accreditation (EA) and International
Laboratory Accreditation Co-operation
(ILAC) for calibration and testing.
The products from the calibration can be
issued with an Inspection report and a
Calibration certicate (non accredited).
Accredited calibration certicate can
also be issued if it is required by the cus-
tomer.
TECHNICAL SUPPORT
Metrel provides the following support to
its customers and distributors:
On-line technical support: any in-
quires related to Metrel products can
be sent onto a designated e-mail ad-
dress:
- helpmetrel.si - GLOBAL market;
- infometrel.co.uk - UK market;
- metrelmetrel.de - GERMAN market.
Technical support line: the technical
support can be obtained also over the
phone:
+386 (0)1 7558 200 - GLOBAL market;
+44 (0) 1924 245 000 - UK market;
+49 (0) 9126 28996-0 - GERMAN market.
B2B web support: for Metrel partners
a B2B zone enables to obtain technical
and marketing information.
Download centre: enables to down-
load les with technical product infor-
mation. Visit www.metrel.si/support/
download-centre.html.
TRAINING CENTER
Metrel d.d. offers to its customers and
distributors:
Training on Metrels instruments:
the product training can be customized
on the customers needs. Metrel can
offer training on technical standards,
measuring and test methods, use and
application of Metrel instruments.
Complete distributor setup training:
when establishing a new distributor,
Metrel can offer a complete pack-
age on product training, repair and
calibration training and assign in es-
tablishing e local calibration and repair
department.
Training for calibration and repair of
Metrel products: this is help for Me-
trels existing and new distributors to
enable a high standard of local support
to customers who purchase a Metrel
product.
Bespoke training for larger end us-
ers: In case that a larger customer is
requesting training, Metrel can organ-
ize the training according to their spe-
cic needs. This can be carried out on
site or at Metrels premises.
Contact us
GLOBAL market
Measuring and Regulation Equipment
METREL d.d.
Ljubljanska c. 77
SI-1354 Horjul
Tel: +386 (0)1 75 58 200
E-mail: metrelmetrel.si
Web: www.metrel.si
Metrel WEB
GERMAN market
Mess und Prftechnik
Metrel GmbH
Orchideenstrae 24
90542 Eckental
Tel.: +49 (0) 9126 28996-0
E-mail: metrelmetrel.de
Web: www.metrel.de
UK market
Test and Measuring Equipment
Metrel UK
Unit 1, Hopton House, Ripley Drive,
Normanton, West Yorkshire, WF6 1QT
Tel.: +44 (0) 1924 245 000
E-mail: infometrel.co.uk
Web: www.metrel.co.uk
METREL is one of the world leading man-
ufacturers and distributor of high quality
electrical measurement and test instru-
ments, providing the market with innova-
tive solutions on the following segments:
Electrical Installation Safety
Metrel offers single and multifunctional
electrical installation testers. The instru-
ments are used for initial and periodic test-
ing of domestic and industrial installations,
testing of single and multiphase systems
and testing of TT, TN, IT and 115 V systems.
Metrel meters offer wide selection of func-
tionalities and measurements (depending
on the model), can be downloadable or non-
downloadable. All meters comply with the
European standard IEC/EN 61557.
High Voltage Diagnostics
Metrels high voltage diagnostic equip-
ment (5 ... 10 kV) is used for testing
insulation resistance of rotating machin-
ery and cables, production line periodic
testing and maintenance, troubleshoot-
ing and analysis of all kinds of insulation
problems. It gives effective readings in
high noise environments such as high
voltage substations and switchyards.
Some of key features of Metrels instru-
ments (depends on the model) are PI,
DD, DAR testing, R(t) graph plotting,
high 5 mA charging current, selectable
noise rejection lters, etc.
Portable Appliance / Machine / Switch-
board Safety
Metrels testers can be used in profes-
sional PAT testing, general PAT testing,
factory / warehouse PAT testing, multi-
location PAT testing and after repair
safety testing. Metrels instruments of-
fer a selection of key features for exam-
ple auto sequencing, automatic testing,
Pass / Fail evaluation of results, RCD
testing, project uploading, bar-coding
system and Pass / Fail barcode label
printing, ash test, test of both 230 V ap-
pliances and 115 V appliances and many
more.
Power Quality Analysis
The power quality analysers can be
widely used for general power quality
assessment in distribution and industrial
low and middle voltage electric systems
(according to EN 50160), capturing and
recording of power supply events, icker
measurement, power factor correction
measurements, harmonics measure-
ments, transients recording and over-
voltage protection devices performance
testing, assessment of UPS, consump-
tion prole recording, ect.
Lan Cabling Certication
Metrels LAN testers are designed to be
used for verication of copper cabling
networks up to CAT VI / Class E, trouble-
shooting and fault nding of connections
/ links, troubleshooting in IT networks.
Indoor Environment Quality
Metrels indoor environmental measur-
ing instruments are used for measure-
ment, recording and analysis of various
indoor ambient parameters. The testers
integrate a number of innovative solu-
tions and t the most demanding ap-
plications such as testing of indoor air
quality, factory climatic conditions, light-
ning conditions; heat, ventilation and air
conditioning systems testing, indoor or
dry outdoor sound level measurement,
industrial sound measurement, band-
pass and acoustic lter testing, calibra-
tion work, acoustic equipment testing
and much more.
Digital Multimeters / Clamp Meters /
Voltage And Continuity Testers
The digital multimeters, clamp meters
and voltage continuity testers are used
for general / basic testing up to high lev-
el industrial testing, electronic fault nd-
ing, eld servicing and heavy duty elec-
trical testing. Some of the key features
(depending on the model) are TRMS
testing, high accuracy, temperature
measurement, lead alert, conductance,
PC communication, autocheck function,
recording of data, etc.
Metrel WEB page offers you:
General information about our prod-
ucts with quick and practical SEARCH
function for product searching.
Detailed information about our products
in extended product specications.
Latest information about training and
seminars.
Service information.
Download centre.
Helpdesk, improved with ticketing
system.
Answers to common questions re-
lated to our products under Frequent
Asked Questions (FAQ) rubric.
News and information about exhibi-
tions, fairs,meetings and conferences.
Faster and more sufcient activities in
relations with our worldwide distribu-
tors (B2B).
Links to other interesting sites that of-
fers information about occupation safety,
metrology, technical heritage, standardi-
zation, regulations, technical experience.
6
Contents
Electrical Installation Safety
1.1 - 1.66
High Voltage Diagnostics
2.1 - 2.34
Appliance / Machine /
Switchboard Safety
3.1 - 3.40
Power Quality Analysis
4.1 - 4.26
LAN Cabling Certication
5.1 - 5.08
Indoor Environment Quality
6.1 - 6.16
Digital Multimeters / Clamp
Meters / Voltage and
Continuity Testers
7.1 - 7.30
Variable transformers /
Equipment for laboratories
and Schools
8.1 - 8.05
GOOD TO KNOW
Testing the Safety of Electrical Installation 1 - 02
PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER
Selection Guide for Photovoltaic and Electrical installations Testers 1 - 07
MI 3108 EurotestPV 1 - 08
MI 3109 EurotestPV Lite 1 - 10
MULTIFUNCTIONAL TESTERS
Selection Guide for Multifunctional Testers 1 - 12
MI 3105 EurotestXA 1 - 14
MI 3101 EurotestAT 1 - 16
MI 3102H BT EurotestXE 2,5 kV NEW 1 - 18
MI 3102 BT EurotestXE NEW 1 - 20
MI 3100 SE EurotestEASI NEW 1 - 22
MI 3100 s EurotestEASI NEW 1 - 24
MI 3125BT EurotestCOMBO 1 - 26
MI 3125 EurotestCOMBO 1 - 28
MI 2086 Eurotest 61557 1 - 30
MI 2088 Earth - Insulation Tester 1 - 32
SINGLE-FUNCTIONAL TESTERS
Selection Guide for Single-functional Testers 1 - 34
MI 3121 Insulation / Continuity 1 - 36
MI 3122 Z Line-Loop / RCD 1 - 38
MI 3123 Earth / Clamp 1 - 40
MI 3110 EurotestIM 1 - 42
MI 2126 Earth 2/3 1 - 44
MI 3103 GigaOhm 1 kV 1 - 45
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
A 1143 Euro Z 290 A 1 - 46
MI 2093 Line Tracer 1 - 47
A 1199 adapter 1 - 48
CS 2099 Eurocheck 1 - 49
DEMONSTRATION BOARDS
MI 3088 PV Demonstration Board 1 - 50
MA 2067 Demonstration Board 1 - 51
MI 3099 Demonstration Board 1 - 52
MI 2166 Demonstration Board 1 - 53
PC SOFTWARE
EuroLink PRO and EuroLink PRO Plus 1 - 54
A 1431 EuroLink Android 1 - 56
A 1428 EuroLinkPV Android 1 - 57
Selection Guide for EIS Accessories 1 - 58
E
l
e
c
t
r
i
c
a
l

I
n
s
t
a
l
l
a
t
i
o
n

S
a
f
e
t
y
C
o
m
p
l
i
a
n
t

w
i
t
h

I
E
C
/
E
N

6
1
5
5
7

E
l
e
c
t
r
i
c
a
l

I
n
s
t
a
l
l
a
t
i
o
n

S
a
f
e
t
y

S
t
a
n
d
a
r
d

MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
Electrical Installation Safety
Electrical Installation Safety Electrical Installation Safety
1. 2 1. 3 Accessories: page 1.58 Accessories: page 1.58
Find out more about testing safety of
electrical installations
According to European standards require-
ments electrical installation safety testing
includes a combination of following tests:
Insulation resistance,
Continuity of protective conductors
and equipotential bonding,
RCD testing,
Line and fault loop impedance,
Earth resistance testing (two-wire
method without probes, three / four-
wire method with two probes, method
with current clamp and two probes,
method with two current clamps)
Specic earth resistance,
Phase sequence, voltage and frequency.
These tests are performed in order to en-
sure that the requirements are met for the
protection of persons, livestock and prop-
erty against the risk of electric shock and
to ensure that the automatic disconnec-
tion of the supply is performed correctly.
Insulation resistance
The insulation is intended to prevent any
contact with live parts and withstanding
mechanical, chemical, electrical and ther-
mal stresses. Insulation test discloses in-
sulation faults caused by pollution, mois-
ture, deterioration of insulation materials
etc. Insulation resistance measurement is
covered by the IEC / EN 61557-2 standard.
The power must be switched off and the
installation must be disconnected before
performing this test to ensure that the
test voltage will not be applied to other
equipment electrically connected to the
circuit to be tested, particularly devices
sensitive to voltage surges.
Insulation resistance shall be measured
between:
Line conductors,
Line and PE conductors,
Line and Neutral conductors,
Neutral and PE conductors.
Test circuit for insulation resistance measurement
Test circuit for insulation resistance measurement
The insulation resistance test is per-
formed with a DC voltage on a dead sys-
tem and the resistance must be above
the minimum limit set out in the appro-
priate standards and regulations.
Limit values for electrical installations
acc. to IEC 60364-6:
Ratedt voltage of
circuit (V)
DC test
voltage (V)
Insulation
resistance (M)
LV secondary switch-
board or LV main
switshboard
250 0.5
Less than or equal to
500 V including LV main
switchboard
500 1.0
Greater 1.000 1.0
METRELs hint:
EurotestAT and EurotestXA have built-in the
Insulation ALL function which enables
performing of 3-port insulation test (L-N,
L-PE, N-PE or L1-L2, L1-L3, L2-L3) in one
step. This is a very time saving feature es-
pecially if measuring insulation on outlets.
Continuity of protective conductors
and equipotential bonding
The purpose of continuity measurement
is to check the continuity of the protec-
tive conductors, the main and supple-
mentary equipotential bonds.
The test is carried out using a measure-
ment instrument capable of generating
a no-load voltage of 4 to 24 V (DC or AC)
with a minimal current of 200 mA.
Continuity test is covered by the EN
61557-4 standard.
The measured resistance must be lower
than a threshold specied by the stand-
ard applicable to the installation tested,
which is usually 2 . As the resistance
value is low, the resistance of the meas-
urement leads must be compensated,
particularly if very long leads are used.
METRELs hint:
EurotestAT and EurotestXA can perform the
N PE loop test between instruments N
and PE test terminals. This makes testing
with the plug test cable on outlets possible.
Test circuit for continuity R200 mA measurement
Test circuit for continuous resistance measurement
RCD testing
RCD devices are used as protection
against dangerous fault voltages and fault
currents. Various test and measurements
are required for verication of RCDs in
RCD protected installations. Measure-
ments are based on the EN 61557-6
standard.
Scope of RCD test is:
to verify effectiveness and proper op-
eration of the RCDs;
to verify disconnection times and trip
out currents of RCDs;
to verify that there are no or limited pre-
sent fault currents in the installation.
The following measurements and tests
of RCDs can be performed:
Contact voltage,
Trip-out time,
Trip-out current,
RCD autotest.
Circuit for testing RCD
METRELs hint:
METREL installation testers have built-in
the RCD AUTO function which performs
RCD testing at x1/2, x1 and x5 current mul-
tipliers at both 0 and 180 automatically.
With this function all relevant RCD tests
can be carried out in one step which is very
simple and time saving feature.
RCD selection table according to their
sensitivity:
AC type

A type

B type

t
U
t
U
t
U

t
U
t
U
t
U
No
response

t
U
t
U
t
U
No
response
No
response

Line impedance
Line impedance is measured in loop
comprising of mains voltage source
and line wiring (between the line and
neutral conductors or between lines on
a 3-phase system). It is covered by re-
quirements of the EN 61557-3 standard.
Scope of line impedance test is:
to verify effectiveness of installed over
current devices;
to verify internal impedance for supply-
ing purpose.
The line-neutral short circuit loop consists of:
Power transformer secondary imped-
ance ZT,
ZL (phase wiring from source to fault),
ZN (neutral wiring from source to fault).
The line to neutral impedance is the
sum of impedances and resistances that
forms the line to neutral loop. In three
phase system there are three line-neu-
tral impedances (ZL1-N, ZL2-N, ZL3-N).
ZLN = ZL+ ZN+ZTLN
The prospective short circuit current IPSC
is dened as:
Circuit for measurement of line impedance
IPSC must be higher than current for rated
disconnection time of the over current
disconnection device. The line neutral
(or line - line) impedance should be low
enough e.g. prospective short circuit cur-
rent high enough that installed protection
device will disconnect the short circuit
loop within the prescribed time interval.
METRELs hint:
METREL installation testers have built-in
tables with fuses and RCDs parameters.
When line test is performed, the meas-
ured value is automatically compared
to the maximum values set out in the
standard (EN 61557) and either a PASS
or FAIL symbol will appear on the screen
to inform the user if the result is within
the required limits.
Fault loop impedance
Fault loop is a loop comprising mains
source, line wiring and PE return path to the
mains source. The measurement is cov-
ered by requirements of the EN 61557-3
standard.
Scope of loop impedance test is:
to verify effectiveness of installed over
current and / or residual current discon-
nection devices;
to verify fault loop impedances, prospec-
tive fault currents and fault voltage values.
In TN systems the fault loop ZL-PE consists of:
ZT (power transformer secondary impedance);
ZL (phase wiring from source to fault);
RPE (PE / PEN wiring from fault to source).
The fault loop impedance is the sum of
impedances and resistances that forms
the fault loop.
ZLPE = ZL+ RPE+ZT
The prospective fault current IPSC is dened as:
Circuit for measurement of fault loop impedance
>Ia
____ ULPE
ZLPE
IPSC=
____ ULN
ZLN
IPSC= >Ia
Electrical Installation Safety Testing Electrical Installation Safety Testing
METRELs hint:
METREL installation testers have built-in
tables with fuses and RCDs parameters.
When loop test is performed, the meas-
ured value is automatically compared
to the maximum values set out in the
standard (EN 61557) and either a PASS
or FAIL symbol will appear on the screen
to inform the user if the result is within
the required limits.
Earth resistance
Earth resistance testing is used on TN, TT
and IT systems to ensure that the resist-
ance of the earth electrode is sufciently
low so that, in the case of a fault, a dan-
gerous voltage does not appear on any
parts of the installation or on any appli-
ances which have a connection to earth.
The measurement conforms to the EN
61557-6 standard.
Scope of earth resistance test is:
Earthing of exposed conductive parts
assures that the voltage on them stays
below dangerous level in case of a fault.
In TN installations the earthing is realized
at the source and / or distribution points
thats why the earthing resistances are
usually very low (below 1).
TT installations have their own main
earthing. The resistances are usually
higher than in TN systems (from few
up to several hundred ). Because of
this dangerous fault voltages and body
currents can occur at relatively low fault
currents. Therefore TT systems usually
have additional RCD protection.
The following earth resistance measur-
ing methods are available:
Standard 3-wire (4-wire) method for
standard resistance to earth measure-
ments;
3-wire (4-wire) method with one
clamp, for measuring resistance to
earth of individual earthing rods;
Two clamps method for measuring re-
sistance to earth of individual earthing
rods (recommended in IEC 60364-6 for
urban areas);
Specic earth resistance (is carried out
in order to assure more accurate calcu-
lation of earthing systems e.g. for high-
voltage distribution columns, large in-
dustrial plants, lightning systems etc.).
GOOD TO KNOW GOOD TO KNOW
Electrical Installation Safety Electrical Installation Safety
1. 4 1. 5 Accessories: page 1.58 Accessories: page 1.58
Connection diagrams:
Circuits for three-wire mesurement
Circuits for three-wire mesurement
Circuit for two clamps measurement
Circuit for one clamp measurement
Circuit for measurement of spesic earth resistance
Recommended earth resistance meas-
uring methods:
TN system
L1
L2
L3
PE TN
N
Two clamps method (clamps around main N/PE cable).
TT system
L1
L2
L3
PE
N
TT
Two-wire method (test from the socket between N and PE)
IT system
L1
L2
L3
PE
N
TT
Three-wire method (test leads to auxiliary rods in triangle)
Lightning conductor
Two clamps method
Limits:
2 above ground,
10 complete system,
20 individual electrode or 8% of spe-
cic earth resistance.
Phase sequence, voltage and frequency
Phase sequence test is used for deter-
mining of line voltages order in 3-phase
systems. This order denes direction of
rotation of motors and generators.
Phase sequence measurement con-
forms to the EN 61557-7 standard.
Circuit for voltage measurements
Circuit for voltage measurement, frequency and phase se-
quence
METRELs hint:
METREL installation testers have on-
line voltage monitor which in all func-
tions displays on one screen voltages
between L to PE, L to N and N to PE
(single phase system) or L1 to L2, L2 to
L3 and L1 to L3 (3-phase system). This
feature allows quickly identify incorrect
connections, disconnected wires or in-
correct voltages.
PE test terminal
A very dangerous situation can occur in
case dangerous voltage is applied to the
PE wire or other accessible metal parts.
A common reason for this fault is incor-
rect wiring. Metrels instruments are
equipped with touchable PE electrode
(TEST key). When touching TEST key in
all functions that require mains supply
the user automatically performs test for
the presence of phase voltage at the PE
protection terminal.
Example for application of PE test terminal
Electrical Installation Safety Testing
Overvoltage category
The overvoltage category species
the highest mains voltage (or lightning
strike, short circuit due to incorrect use,
etc.) that the instrument can withstand
without danger for the tester or for the
object being measured. The standard
species four overvoltage categories.
The overvoltage category affects com-
ponent sizing via the air gap. The higher
the category, the bigger is the distance
to the power source.
CAT I - electronic devices, signal level.
CAT II - domestic appliances, portable
appliances, single-phase loads, sockets,
(>10 m from CAT III; >20 m from CAT IV).
CAT III - three-phase distribution sys-
tems, lighting systems in large buildings,
distribution panels.
CAT IV - three-phase systems on power
stations, electricity meters, outdoor instal-
lations and supply cable incoming feed.
CAT II CAT I CAT IV CAT III
AUTO SEQUENCE


is a unique patented by Metrel testing pro-
cedure which allows performing of series
of requested installation tests with a sin-
gle press of TEST button. The results of
each test are automatically compared to
pre-set limits and PASS / FAIL evaluated.
While ensuring efcient, fast and easy
way of installation safety testing AUTO
SEQUENCE

guarantees absolute safety


of operator due to automatic detection of
possible irregular installation conditions.
Denite number of test sequences is al-
ready stored in the instrument. Besides,
user can program and store custom test
sequences.
The user can choose appropriate pre-
programmed AUTO SEQUENCE

pro-
cedure according to following criterions:
which part of electrical installation will
be tested;
which earthing system is implemented
(TN, TT or IT);
Electrical Installation Safety Testing
is the installation single- or three-phase;
is the RCD present in the installation.
To simplify the selection of the appro-
priate test sequence the detailed ow
chart is supplied with the instrument.
After choosing the AUTO SEQUENCE


and setting the limits the user just has
to press TEST button and the sequence
will automatically perform all predened
tests. When the sequence is nished,
Guide through Verication on Low-voltage electrical installations : IEC 60364-6
GOOD TO KNOW GOOD TO KNOW
the instrument will display overall PASS /
FAIL decision. All the results can be saved
to the structured instruments memory at
once for further data verication and au-
tomatic generation of test report with the
help of the PC SW EuroLink PRO.
The revolutionary AUTO SEQUENCE


procedure allows performing testing up
to 5 times faster in comparison with con-
ventional methods.
Electrical Installation Safety Electrical Installation Safety
1. 6 1. 7 Accessories: page 1.58 Accessories: page 1.58
PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER
Electrical and Photovoltaic
Installations Tester:
MI 3108 EurotestPV
Part No.
MI 3108 MI 3109
EurotestPV EurotestPV Lite
Features Description
ELECTRICAL
INSTALLATION
SAFETY
Insulation resistance up to 1000 V
Continuity 200 mA
Line / Loop Impedance
RCD A, AC, B
Earth resistance
Rotary eld
PV GENERATOR
MEASUREMENTS
Isc, Uoc 1000 V / 15 A 1000 V / 15 A
Automatic test sequence
I-V curve
Umpp, Impp, Pmax
extrapolation to STC *
Rs (calculated in PC SW)
ENVIRONMENT
MEASUREMENTS
Irradiance *
Module temperature *
PV SYSTEM POWER
MEASURENMENTS
DC side measurements U, I, P
AC side measurements (single phase) U, I, P
PV and inverter energy conversion efciency
EXTENDED POWER
FUNCTIONALITY
P, Q, S, THDU, PF/cos
AC/DC current
Scope function
Energy
Harmonics (up to 11
th
)
GENERAL DATA
Memory size
I-V curve: ca. 500 meas.
Other: ca 1800 meas.
Supply 6 x AA
Built-in battery charger
Display 128 x 64 BW LCD
Overvoltage category
CAT II / 1000 V DC
CAT III / 600 V
CAT IV / 300 V
PC connectivity
PC Software EuroLink PRO EuroLink PRO
Weight (kg) 1.3 1.3
Dimensions (mm) 230 x 103 x 115 230 x 103 x 115
* Environment data can be entered manually or measured with optional accessory
Selection Guide for Photovoltaic and Electrical installations Testers
Electrical Installation Safety Electrical Installation Safety
1. 8 1. 9 Accessories: page 1.58 Accessories: page 1.58
APPLICATION:
Testing, evaluations and troubleshoot-
ing of photovoltaic installations.
Power and energy efciency measure-
ments (AC and DC).
Initial and periodic testing of domestic
and industrial single and three-phase
electrical installations.
STANDARDS:
Functionality:
IEC/EN 61557 series;
IEC 62446 (photovoltaics).
Other reference standards for testing:
BS 7671;
EN 61008;
EN 61009;
EN 60364-4-41;
AS/NZ 3760
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1;
EN 61010-2-030;
EN 61010-031;
EN 61010-2-032
Electrical installations
RCD Auto: Automated RCD testing pro-
cedure signicantly reduces test time.
Trip Lock function: Loop impedance
test are performed without tripping
the RCD.
B type RCD testing: is supported.
Earth resistance measurement: instru-
ment supports 3-wire earth resistance
testing.
Built-in fuse tables: for automatic
evaluation of the line / loop impedance
results.
Online voltage monitoring: monitors
all 3 voltages in real time.
Scope function: real-time U/I scope.
Harmonics analysis: 1-phase power
and energy measurements with up to
11th harmonics analysis is supported.
Memory: Up to 1800 test results or
up to 500 graphical results with times-
tamp can be stored in internal memory.
BT connectivity: it enables BT com-
munication with Android tablets and
smart phones via optional BT dongle.
Downloadable: PC SW EuroLink PRO
enables downloading, review, analy-
ses and printing of test results.
MEASURING FUNCTIONS:
Photovoltaic installations:
Measurements on DC side of PV in-
stallation:
Voltage, current, power;
Uoc (Open Circuit Voltage) and Isc
(Short Circuit Current);
I - U curve of PV modules and strings;
Irradiance;
Module temperature.
Measurements on AC side of PV in-
stallation (power quality):
Voltage, current, frequency, power,
PF, energy, harmonics;
Efciency of PV module, inverter, PV
system calculation.
Electrical installations:
Insulation resistance;
Continuity of PE conductors;
Line impedance;
Loop impedance (sub-functions with
high current and without RCD tripping);
RCD testing (type AC, A and B);
Earth resistance;
AC current (load and leakage);
TRMS voltage, frequency, phase se-
quence;
Power, energy, harmonics.
KEY FEATURES:
Photovoltaic installations:
Calculation of STC values: the meas-
ured current and voltage values are,
according to environment conditions,
recalculated to Standard Test Condi-
tion values which makes possible, to
compare the results even if they were
taken under different test conditions.
Graphical representation: the I-V
characteristic of PV module or string is
graphically represented on LCD display.
Power and efciency measurements:
2 voltage & 2 current channels for si-
multaneous AC & DC parameters
measurements.
PV Remote Unit: Optional unit for si-
multaneous measurements of solar irra-
diation and temperature of PV module.
MI 3108 EurotestPV
MI 3108 EurotestPV is a combined photovoltaic tester and electrical installations safety tester. It enables complete test-
ing of electrical installations according to EN 61557 standards and in addition performs all necessary tests required on
single-phase photovoltaic (PV) installations. This includes all of the tests as required by EN 62446, but also includes I - U
characteristic, Calculation of STC values and power measurements on Inverters DC and AC sides. The unit is designed for
the demanding working conditions (up to 1000 V, with 15 A DC). To greatly improve user safety the MI 3108 EurotestPV
comes with the PV Safety Probe which ensures safe disconnection every time.
PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER
MI 3108 ST
Instrument MI 3108 EurotestPV
Soft carrying bag, 2 pcs
Schuko-plug test cable
Test lead, 3 x 1.5 m
Test probe, 4 pcs (red, green, blue, black)
Crocodile clip, 3 pcs (red, green, blue, black)
PV Safety Probe
PV MC3/4 male/female adapters
AC/DC current clamp
PV Reference Cell
Temperature probe
USB and RS232 - PS/2 cable
Power supply adapter + 6 NiMH batteries,
type AA
PC SW EuroLink PRO
Set of carrying straps
Short instruction manual
Instruction manual and handbook on CD
Calibration certicate
MI 3108 PS
MI 3108 ST
EurotestPV Remote
Tip commander
PC SW EuroLink PRO Plus licence
STANDARD SET:
PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER
TECHNICAL DATA:
PHOTOVOLTAIC INSTALLATION MEASUREMENTS
Function Measuring range Basic accuracy
Voltage
0 VDC ... 999 VDC
0 VAC ... 999 VAC
I-V m.: 0 VDC ... 999 VDC
(1.5 % of reading + 5 digits)
(1.5 % of reading + 3 digits)
(2 % of reading + 2 digits)
Current
Panel m.: 0.0 mA ... 300 ADC
Invert. m.: 0.0 mA ... 300 AAC
I-V m.: 0.00 A ... 15 ADC
(1.5 % of reading + 5 digits)
(1.5 % of reading + 3 digits)
(2 % of reading + 3 digits)
Power
Panel m.: 0 ... 200 kW
I-V m.: 0 ... 15 kW
(2.5 % of reading + 6 digits)
(3 % of reading + 5 digits)
Energy 0.000 Wh - 1999 kWh
U / I curve 1000 V / 15 A / 15 kW
Harmonics up to 11
th
Irradiation 0 ... 2000 W/m
2
(5 % of reading + 5 digits)
Temperature -10 C ... + 85 C 5 digits
ELECTRICAL INSTALLATION MEASUREMENTS
Function Measuring range Basic accuracy
Insulation resistance (EN 61557-2)
U = 50, 100, 250 VDC:
R: up to 199.9 M
U = 500 VDC, 1 kVDC:
R: up to 999 M
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Continuity, 200 mA (EN 61557-4) 0.00 ... 1999 (3 % of reading + 3 digits)
Continuity, 7 mA 0.0 ... 1999 (5 % of reading + 3 digits)
Loop impedance (EN 61557-3) 0.00 ... 9.99 k (5 % of reading + 5 digits)
Line impedance (EN 61557-3) 0.00 ... 9.99 k (5 % of reading + 5 digits)
Voltage 0 VAC ... 550 VAC (2 % of reading + 2 digits)
Frequency 0.00 Hz ... 499.9 Hz (0.2 % of reading + 1 digits)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC 0.0 V ... 99.9 V (-0 % / +15 %) of reading
- Trip-out time 0 ms ... max. time 1 ms
- Trip-out current 0.2 x IN ... 2.2 x IN 0.1 x IN
Earth resistance (EN 61557-5) 0.00 ... 9999 (5 % of reading + 5 digits)
General Main unit Remote unit
Display 128 x 64 dots matrix display with backlight 128 x 64 dots matrix display with backlight
Power supply 6 x 1.2 V NiMH batteries, type AA 6 x 1.2 V NiMH batteries, type AA
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class double insulation
COM port RS232 and USB RS232
Dimensions 230 x 103 x 115 mm 140 x 230 x 80 mm
Weight 1.3 kg 1.0 kg
MI 3108 PS
READY
Electrical Installation Safety Electrical Installation Safety
1. 10 1. 11 Accessories: page 1.58 Accessories: page 1.58
STANDARDS:
Functionality:
IEC/EN 61557 series;
IEC 62446 (photovoltaics).
Other reference standards for testing:
BS 7671;
EN 61008;
EN 61009;
EN 60364-4-41;
AS/NZ 3760
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1;
EN 61010-2-030;
EN 61010-031;
EN 61010-2-032
Efciency calculations: 2 voltage & 2
current channels for simultaneous AC
& DC parameters measurements.
PV Remote Unit: Optional unit for si-
multaneous measurements of solar irra-
diation and temperature of PV module.
Graphical representation of mod-
ules I - U curve: the I-V characteristic
of PV module or string is graphically
represented on LCD display.
Memory: Up to 1800 test results or
up to 500 graphical results with times-
tamp can be stored in internal memory.
BT connectivity: it enables BT com-
munication with Android tablets and
smart phones via optional BT dongle.
Downloadable: PC SW EuroLink PRO
enables downloading, review, analy-
ses and printing of test results.
APPLICATION:
First inspection Testing.
Periodic maintenance tests.
Evaluation and troubleshooting of pho-
tovoltaic installations.
Power and efciency measurements
(AC and DC).
MEASURING FUNCTIONS:
Photovoltaic installations:
Measurements on DC side of PV in-
stallation:
Insulation resistance;
Continuity of PE conductors;
Uoc (Open Circuit Voltage) and Isc
(Short Circuit Current);
I - U curve of PV modules and strings;
Voltage, current and power of strings
and inverters;
Irradiance;
Module temperature.
Measurements on AC side of PV in-
stallation:
Voltage, current, power;
Efciency of PV module, inverter, PV
system calculation.
KEY FEATURES:
Insulation and I-U curve measure-
ments in one instrument: with MI
3109 only one instrument is needed
to perform insulation measurements
with up to 1000V for proong the PV
installation safety and I-U curve meas-
urements needed for evaluation and
troubleshooting of PV modules or
strings.
Autotest: This function is intended to
perform a complete set of tests ac-
cording to EN 62446 on PV modules or
strings with pressing only one button:
insulation resistance between positive
output and earth;
insulation resistance between nega-
tive output and earth;
open circuit voltage;
short circuit current.
Calculation to STC values: the meas-
ured current and voltage values are,
according to environment conditions,
recalculated to Standard Test Condi-
tion values which makes possible to
compare the results of different meas-
urements even if they were taken un-
der different test conditions.
MI 3109 EurotestPV Lite
MI 3109 EurotestPV Lite is a photovoltaic (PV) tester. It performs all necessary tests required on photovoltaic installations.
This includes all of the tests as required by EN 62446, but also includes I - U characteristic measurements, calculation of STC
values and power measurements on Inverters DC and AC sides (single-phase only). MI 3109 EurotestPV Lite is optimized
for PV tests therefore the Autotest operation mode is implemented which is intended to perform a complete set of test
needed for verification of PV installations according to EN 62446 with pressing off only one button. With this instrument
the tests for the first inspection of PV systems as well as periodic maintenance tests, evaluation tests or troubleshooting
tests are possible. With optional accessories the same PV test functionality as with MI 3108 EurotestPV is available.
MI 3109 ST
Instrument MI 3109 EurotestPV Lite
Soft carrying bag
Universal PV test lead, 3 x 1.5 m
PV Continuity test lead, 2 x 1,5 m
Test probe, 3 pcs (red, blue, green)
Crocodile clip, 3 pcs (red, blue, green)
PV MC3/4 male/female adapters
AC/DC current clamp
Power supply adapter + 6 NiMH batteries,
type AA
USB and RS232 - PS/2 cable
PC SW EuroLink PRO
Carrying strap
Short instruction manual
Instruction manual and handbook on CD
Calibration certica
MI 3109 PS
MI 3109 ST
EurotestPV Remote
PV Safety Probe
PV Reference Cell
Temperature probe
Soft carrying bag
PC SW EuroLink PRO Plus licence
STANDARD SET:
TECHNICAL DATA:
PHOTOVOLTAIC INSTALLATION MEASUREMENTS
Function Measuring range Basic accuracy
Voltage
0 VDC ... 999 VDC
0 VAC ... 999 VAC
I-V m.: 0 VDCC ... 999 VDC
(1.5 % of reading + 5 digits)
(1.5 % of reading + 3 digits)
(2 % of reading + 2 digits)
Current
Panel m.: 0.0 mA ... 300 ADC
Invert. m.: 0.0 mA ... 300 AAC
I-V m.: 0.00 A ... 15 ADC
(1.5 % of reading + 5 digits)
(1.5 % of reading + 3 digits)
(2 % of reading + 3 digits)
Power
Panel m.: 0 ... 200 kW
I-V m.: 0 ... 15 kW
(2.5 % of reading + 6 digits)
(3 % of reading + 5 digits)
U / I curve 1000 V / 15 A / 15 kW
Irradiation 0 ... 2000 W/m
2
(5 % of reading + 5 digits)
Temperature -10 C ... + 85 C 5 digits
ELECTRICAL INSTALLATION MEASUREMENTS
Function Measuring range Basic accuracy
Insulation resistance (EN 61557-2)
U = 50, 100, 250 VDC:
R: up to 199.9 M
U = 500 VDC, 1 kVDC:
R: up to 999 M
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Continuity, 200 mA (EN 61557-4) 0.00 ... 1999 (3 % of reading + 3 digits)
Continuity, 7 mA 0.0 ... 1999 (5 % of reading + 3 digits)
Display 128 x 64 dots matrix display with backlight
Power supply 6 x 1.2 V NiMH batteries, type AA
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class double insulation
COM port RS232 and USB
Dimensions 230 x 103 x 115 mm
Weight 1.3 kg
MI 3109 ST
PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER
READY
Electrical Installation Safety Electrical Installation Safety
1. 12 1. 13 Accessories: page 1.58 Accessories: page 1.58
Selection Guide for Multifunctional Testers
MULTIFUNCTIONAL INSTALLATION TESTERS
Part No.
MI 3105 (EU) MI 3101 NEW MI 3102H BT NEW MI 3102 BT NEW MI 3100 SE NEW MI 3100 s MI 3125 BT MI 3125 MI 2086 (EU) MI 2088
EurotestXA EurotestAT EurotestXE 2.5kV EurotestXE EurotestEASI EurotestEASI EurotestCOMBO EurotestCOMBO Eurotest 61557 Earth Insulation
Features Description
INSULATION
Insulation resistance
Test voltage (VDC) 50 1000 50 1000 50 2500 50 1000 50 1000 50 1000 50 1000 50 1000 50 1000 50 1000
Autotest insulation L-PE, N-PE, L-N
Diagnostic test (PI, DAR calculation)
CONTINUITY AND
LOW RESISTANCE
MEASUREMENT
Contunuity of PE conductors with automatic polarity
change, test current 200 mA

Low resistance measurement (continuous measurement),
test current 7 mA

LINE / LOOP
IMPEDANCE
Line impedance with Ipsc calculation
Loop impedance with Ipsc calculation
RCD Trip Lock loop impedance (R)
Built-in fuse tables for PASS / FAIL evaluation
RCD TESTING
Contact voltage measurement without RCD tripping
RCD trip-out time
RCD trip-out current with rising test current
Automatic testing of RCDs
RCD type (general and selective) A, AC, B A, AC, B A, AC A, AC, B A, AC A, AC A, AC, B A, AC A, AC
VOLTAGE,
FREQUENCY
AC voltage measurement
Online voltage monitor
Frequency measurement
PHASE SEQUENCE L1 - L2 - L3
EARTH
MEASUREMENTS
Earth resistance 3-(4-)wire method
Earth resistance 3-(4-)wire method with additional
current clamp
Option
Earth resistance measurement with 2 current clamps Option Option Option Option Option
Specic earth resistance Option Option (without adapter)
AUTO SEQUENCE
Automatic installation safety testing on Switchboards and Circuts
Predined mini Autosequences
OTHER
MEASUREMENTS
TRMS leakage / load current Option Option Option
Illuminance measurement Option Option Option Option
Varistor test
Fuse / fault locator Option Option Option
High resolution loop impedance (m) Option Option Option
Insulation Monitoring Devices (IMD) testing (IT systems)
First fault leakage current (ISFL) measurement (IT
systems)

OTHER FEATURES
Nominal frequency range 14 500 Hz 14 500 Hz 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz
PASS / FAIL evaluation of test results
IT earthing mode systems support
Touch electrode
HELP menu
COMMUNICATION
PORTS
RS232 / USB /Option /Option
Bluetooth Option Option Option
MEMORY
SOFTWARE
Number of memory levels / memory locations 10 / 2000 10 / 2000 4 / 1800 4 / 1800 4 / 1800 4 / 1800 4 / 1700 3 / 3000 2 / 1000
Professional PC SW
Advanced PC SW Option Option Option Option Option
GENERAL DATA
Safety category
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 300 V
CAT II / 600 V
CAT III / 300 V
CAT II / 600 V
Batteries 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 4 x C 4 x C
Built-in battery charger
Wieght (kg) 1.37 1.32 1.31 1.31 1.31 1.31 1.0 1.0 2.1 1.7
Dimensions (mm) 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 140 x 80 x 230 140 x 80 x 230 265 x 110 x 185 265 x 110 x 185
MULTIFUNCTIONAL INSTALLATION TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 14 1. 15 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
munication with Android tablets and
smart phones via optional BT dongle.
PC SW EuroLink PRO included in the
the standard set enables downloading
of test results and parameters and crea-
tion of test reports.
APPLICATION:
Initial and periodic testing of domestic
and industrial installations;
Testing on high and low frequency in-
stallations e.g. testing in aviation, rail-
way networks etc.;
Testing of single and multiphase systems;
Testing of TT, TN, IT and 115 V systems;
High volume testing (industrial, aircraft, rail-
way, mining, chemistry, fery boat);
Medical installation testing.
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; IEC/EN 61008;
IEC/EN 61009; IEC/EN/TR 60755;
BS 7671; AS/NZ 3760; AS/NZ 3018; AS/
NZ 3017; CEI 64.8; HD 384; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety: IEC/EN 61010-1; IEC/EN 61010-031
USB cable directly to the PC with the help
of the software included in the standard set.
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Built-in fuse tables: this unique feature al-
lows automatic evaluation of the line / loop
impedance compared to the regulations.
Online voltage monitoring: monitors
all 3 voltages in real-time.
Upgradeable: if changes occur to the
regulations upgrades can be made to
the rmware to keep the instrument
up to date.
Polarity swap: automatic polarity re-
versal on continuity test.
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, reading up to 1000 M.
Trip Lock function: Zs (RCD) function
performs a loop impedance test with-
out tripping the RCD.
Multi-system testing: tests on TT, TN,
IT and reduced low voltage systems.
Wide frequency range: 14 ... 500 Hz.
Built-in charger & rechargeable batter-
ies: unit has a built-in charging circuit and
comes complete with a set of recharge-
able NiMH batteries.
RCD auto: automated RCD testing pro-
cedure signicantly reduces test time.
B type RCD testing is supported.
BT connectivity: it enables BT com-
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200 mA
test current with polarity change;
Continuity of PE conductors with 7 mA
test current (continuous measurement)
without RCD tripping;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A and B);
Earth resistance (3-wire method, one
clamp method, two clamps method);
Specic earth resistance (option);
TRMS leakage and load currents;
Overvoltage protection devices testing;
Illumination (option);
Tracing the installations (option);
Testing of Insulation Monitoring De-
vices (IMDs);
First fault leakage current in IT systems;
High resolution loop impedance (m).
KEY FEATURES:
Autosequences: Testing of electri-
cal installation safety with AUTO SE-
QUENCE

is up to 5 times faster com-


pared to traditional installation tester.
All-in-one insulation: insualation tests be-
tween L-N, L-PE and N-PE can be performed
simultaneously in less than 10 seconds.
Medical site testing: measurement of
First fault leakage current (ISFL) and insu-
lation monitoring device (IMD) checking.
Structure building: a structure of the
installation (up to 10 levels) can be built
either using the software (which can
then be sent to the instrument) or di-
rectly on the tester so that test results
are always saved on the correct circuit.
Barcode reading support: reading of
data from barcode labelled installation
structure elements for fast naming of
memory locations on the eld.
Fuse location: function enables the lo-
cating of fuses / wires / faults with the
help of the optional A 1191 Fuse locator.
Earth resistance measurement: Test-
er can perform 3-wire earth resistance
testing, one clamp and two clamps
earth resistance and specic earth re-
sistance measurement.
Downloadable: downloads via RS232 or
MI 3105 EurotestXA
The top model of Metrels installation testers is MI 3105 EurotestXA. Features including All-in-one installation safety
testing, AUTO SEQUENCE

testing, integrated characteristics of fuses and RCDs (including B type), PASS / FAIL evaluation
of test results, 10-level memory structure and built-in battery charger make the EurotestXA an exemplary instrument. Ad-
ditional features include TRMS current measurement, 3-wire / one clamp / two clamps earth resistance and 4-wire specific
earth resistance measurements, illumination measurement and fuse / fault locator function. All the results can be quickly
saved and then downloaded via the EuroLink PRO software to the computer for evaluation and professional report gen-
eration after testing. The MI 3105 EurotestXA performs continuity, insulation, RCD, loop, line, voltage, frequency, earth
resistance and phase sequence testing required by the EN 61557 standard.
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U=50, 100, 250 VDC:
R: 0.00 M 19.99 M
20.0 M 99.9 M
100.0 M 199.9 M
U= 500 VDC, 1 kVDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 299 M
300 M 1000 M
0.01 M
0.1 M
0.1 M
0.01 M
0.1 M
1 M
1 M
(5 % of reading + 5 digits)
10 % of reading
20 % of reading
(5 % of reading + 3 digits)
10 % of reading
10 % of reading
20 % of reading
Continuity 200mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
2000 9999
0.01
0.1
1
1
(3 % of reading + 3 digits)
5 % of reading
5 % of reading
Indicator only
Low resistance continuity
measurement, test current 7 mA
(Continuous measurement)
0.0 19.9
20 1999
2000 9999
0.1
1
1
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Indicator only
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
10.0 k 19.9 k
0.01
0.1
1
10
100
(5 % of reading + 5 digits)
Voltage drop 0.0 % 99.9 % 0.1 % Consider accuracy of line impedance
Loop impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 19999
0.01
0.1
1
(5 % of reading + 5 digits)
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency 0.00 Hz 999.99 Hz 0.01 Hz (0.2 % of reading + 1 digit)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0 % / +15 %) of reading 10 digits
(-0 % / +15 %) of reading
- Trip-out time
0.0 ms 40.0 ms
0.0 ms max. time
0.1 ms
0.1 ms
1 ms
3 ms
- Trip-out current
0.2 x IN 1.1 x IN (AC type)
0.2 x IN 1.5 x IN (A type, IN 30 mA)
0.2 x IN 2.2 x IN (A type, IN < 30 mA)
0.2 x IN 2.2 x IN (B type)
0.05 x IN
0.05 x IN
0.05 x IN
0.05 x IN
0.1 x IN
0.1 x IN
0.1 x IN
0.1 x IN
Earth resistance (EN 61557-5) (three-
wire method; one clamp method)
0.00 19.99
20.0 199.9
200 1999
2000 9999
0.01
0.1
1
1
(3 % of reading + 3 digits)
(3 % of reading + 3 digits)
5 % of reading
10 % of reading
Earth resistance
(two clamps method)
0.00 19.99
20.0 30.0
30.1 39.9
0.01
0.1
0.1
(10 % of reading + 10 digits)
20 % of reading
30 % of reading
Specic earth resistance
0.0 m 99.9 m
100 m 999 m
1.00 km 9.99 km
10.0 km 99.9 km
> 100 km
0.1 m
1 m
0.01 km
0.1 km
1 km
5 % of reading
5 % of reading
5 %of reading; 10 %of reading
10 %of reading; 20 %of reading
20 % of reading
TRMS Current
0.0 mA 99.9 mA
100 mA 999 mA
1.00 A 19.99 A
0.1 mA
1 mA
0.01 A
(3 % of reading + 3 digits)
Illuminance (Type B)
0.00 lux 19.99 lux
20.0 lux 199.9 lux
200 lux 1999 lux
2.00 klux 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(5 % of reading + 2 digits)
Varistor Test 0 625 VAC; 0 1000 VDC 1 V (3 % of reading + 3 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 230 x 103 x 115 mm
Weight 1.3 kg
TECHNICAL DATA:
MI 3105 ST
Instrument EurotestXA
Plug commander, 1.5 m
Test lead, 3 x 1.5 m
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
RS232 - PS/2 cable
USB cable
Soft carrying bag
Soft carrying neck belt
PC Software EuroLink PRO
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
MI 3105 EU
MI 3105 ST
Current clamp A 1018 (low range, leakage)
PC Software EuroLink PRO Plus
STANDARD SET:
MI 3105 EU
READY
Electrical Installation Safety Electrical Installation Safety
1. 16 1. 17 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
nication with Android tablets and smart
phones via optional BT dongle.
PC SW EuroLink PRO included in the
the standard set enables downloading
of test results and parameters and crea-
tion of test reports.
APPLICATION:
Initial and periodic testing of domestic
and industrial installations (testing in
aviation, railway networks, agriculture);
Testing of single and multiphase systems;
Testing of TT, TN, IT and 115 V systems;
High volume testing (industrial, aircraft,
railway, mining, chemistry, fery boat).
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; IEC/EN 61008;
IEC/EN 61009; IEC/EN/TR 60755;
BS 7671; AS/NZ 3760; AS/NZ 3018; AS/
NZ 3017; CEI 64.8; HD 384; 0VDE 413
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety:
IEC/EN 61010-1; IEC/EN 61010-031
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Built-in fuse tables: this unique feature
allows automatic evaluation of the line /
loop impedance compared to the regula-
tions.
Online voltage monitoring: monitors
all 3 voltages in real-time.
Upgradeable: if changes occur to the
regulations, upgrades can be made to
the rmware to keep the instrument
up to date.
Polarity swap: automatic polarity re-
versal on continuity test.
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, reading up to 1000 M.
Trip Lock function: Zs (RCD) function
performs a loop impedance test with-
out tripping the RCD.
Multi-system testing: tests on TT,
TN, IT and 115 V systems.
Wide frequency range: 14 ... 500 Hz.
Built-in charger & rechargeable bat-
teries: unit has a built-in charging cir-
cuit and comes complete with a set of
rechargeable NiMH batteries.
RCD auto: automated RCD testing pro-
cedure signicantly reduces test time.
B type RCD testing is supported.
BT connectivity: it enables BT commu-
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200 mA
test current with polarity change;
Continuity of PE conductors with 7 mA
test current (continuous measurement)
without RCD tripping;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A and B);
Earth resistance (3-wire method);
Specic earth resistance (option);
Overvoltage protection devices testing;
Tracing the installations (option);
High resolution loop impedance (m).
KEY FEATURES:
Autosequences: Testing of electri-
cal installation safety with AUTO SE-
QUENCE

is up to 5 times faster com-


pared to traditional installation tester.
All-in-one insulation: insualation
tests between L-N, L-PE and N-PE can
be performed simultaneously in less
than 10 seconds.
Structure building: a structure of the
installation (up to 10 levels) can be built
either using the software (which can
then be sent to the instrument) or di-
rectly on the tester so that test results
are always saved on the correct circuit.
Barcode reading support: reading of
data from barcode labelled installation
structure elements for fast naming of
memory locations on the eld.
Fuse location: function enables the
locating of fuses / wires / faults with
the help of the optional A 1191 Fuse
locator.
Earth resistance measurement: Unit
can perform 3-wire earth resistance
testing and specic earth resistance
measurement.
Downloadable: downloads via RS232
or USB cable directly to the PC with
the help the software included in the
standard set.
MI 3101 EurotestAT
The MI 3101 EurotestAT is the first installation safety tester with automated testing based on patented technology AUTO
SEQUENCE

. This remarkable instrument is equipped with a number of unique features including All-in-one installation
safety testing, integrated characteristics of fuses and RCDs (including B type), PASS / FAIL evaluation of test results and
10-level memory structure. Besides the EurotestAT has additional features like fuse / wire locating facility, specific earth
resistance measuring function and built-in battery charger. All the results can be quickly saved and referenced on the
instrument and then downloaded via the EuroLink PRO software, included in the standard set, to the computer for evalu-
ation and report generation after testing. The MI 3101 EurotestAT performs continuity, insulation, RCD, loop, line, voltage,
frequency, earth resistance testing and phase sequence tests required by the EN 61557 standard.
Instrument EurotestAT
Plug commander, 1.5 m
Test lead, 3 x 1.5 m
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
RS232 - PS/2 cable
USB cable
Soft carrying bag
Soft carrying neck belt
PC Software EuroLink PRO
Short Instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U=50, 100, 250 VDC:
R: 0.00 M 19.99 M
20.0 M 99.9 M
100.0 M 199.9 M
U= 500 VDC, 1 kVDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 299 M
300 M 1000 M
0.01 M
0.1 M
0.1 M
0.01 M
0.1 M
1 M
1 M
(5 % of reading + 5 digits)
10 % of reading
20 % of reading
(5 % of reading + 3 digits)
10 % of reading
10 % of reading
20 % of reading
Continuity of PE conductor with
polarity change, test current 200 mA
(EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
2000 9999
0.01
0.1
1
1
(3 % of reading + 3 digits)
5 % of reading
5 % of reading
Indicator only
Low resistance continuity
measurement, test current 7 mA
(Continuous measurement)
0.0 19.9
20 1999
2000 9999
0.1
1
1
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Indicator only
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
10.0 k 19.9 k
0.01
0.1
1
10
100
(5 % of reading + 5 digits)
Voltage drop 0.0 % 99.9 % 0.1 % Consider accuracy of line impedance
Loop impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 19999
0.01
0.1
1
(5 % of reading + 5 digits)
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency 0.00 Hz 999.99 Hz 0.01 Hz (0.2 % of reading + 1 digit)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0 % / +15 %) of reading 10 digits
(-0 % / +15 %) of reading
- Trip-out time
0.0 ms 40.0 ms
0.0 ms max. time
0.1 ms
0.1 ms
1 ms
3 ms
- Trip-out current
0.2 x IN 1.1 x IN (AC type)
0.2 x IN 1.5 x IN (A type, IN 30 mA)
0.2 x IN 2.2 x IN (A type, IN < 30 mA)
0.2 x IN 2.2 x IN (B type)
0.05 x IN
0.05 x IN
0.05 x IN
0.05 x IN
0.1 x IN
0.1 x IN
0.1 x IN
0.1 x IN
Earth resistance (EN 61557-5)
(three-wire method)
0.00 19.99
20.0 199.9
200 1999
2000 9999
0.01
0.1
1
1
(3 % of reading + 3 digits)
(3 % of reading + 3 digits)
5 % of reading
10 % of reading
Specic earth resistance
0.0 m 99.9 m
100 m 999 m
1.00 km 9.99 km
10.0 km 99.9 km
> 100 km
0.1 m
1 m
0.01 km
0.1 km
1 km
5 % of reading
5 % of reading
5 % of reading; 10 % of reading
10 % of reading; 20 % of reading
20 % of reading
Varistor Test 0 625 VAC; 0 1000 VDC 1 V (3 % of reading + 3 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 230 x 103 x 115 mm
Weight 1.3 kg
MULTIFUNCTIONAL INSTALLATION TESTERS
READY
Electrical Installation Safety Electrical Installation Safety
1. 18 1. 19 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS MULTIFUNCTIONAL INSTALLATION TESTERS
Testing of TT and TN supply systems.
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN 60364;
EN 61008;
EN 61009;
EN 60755;
BS 7671;
AS/NZ 3760;
CEI 64.8;
HD 384;
VDE 413
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1;
EN 61010-031
EN 31010-2-030
EN 31010-2-032
Trip Lock function: loop impedance
test without tripping the RCD.
Built-in charger and rechargeable bat-
teries as standard accessory.
RCD auto: automated RCD testing
procedure.
Bluetooth communication with PC,
Android tablets and smart phones via
built-in BT.
PC SW EuroLink PRO for downloading
of test results and report creation.
EuroLink Android APP, data manage-
ment tool (option).
APPLICATION:
Initial and periodic testing of domestic
and industrial installations.
Testing of Insulation resistance of
transformers, motors, cables, ma-
chines, etc.
Observation of insulation trends.
Testing of single and multiphase sys-
tems.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage
50 V to 2,5 kV and PI, DAR calculation;
Continuity of PE conductors with
200 mA DC test current with polarity
change;
Continuity of PE conductors with 7 mA
test current without RCD tripping;
Continuity RPE with 200 mA AC on
outlet;
Line/Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
Power and harmonics;
RCD testing (general and selective,
type AC, A, F);
Earth resistance (3-wire and 2-clamps
method);
Specic earth resistance with Ro-
adapter (option);
TRMS leakage and load currents (option);
Illumination (option).
KEY FEATURES:
Predened mini AUTO SEQUENCE

s:
Auto TT (U, Zln, Zs, Uc);
Auto TN/RCD (U, Zln, Zs, Rpe);
Auto TN (U, Zln, Zlpe, Rpe).
Insulation range: wide range of insu-
lation test voltages from 100 V to 2500
V, readings up to 20 G.
Insulation diagnostics: polarisation
Index (PI) and Dielectric Absorption
Ratio (DAR) calculation.
Power measurements and harmonics
analysis.
Built-in help screens for referencing
on site.
Built-in fuse tables for automatic evalu-
ation of the line / loop impedance result.
On-line voltage monitoring: monitors
all 3 voltages in real-time.
Polarity swap: automatic polarity re-
versal on continuity test.
MI 3102H BT EurotestXE 2,5 kV
MI 3102H BT EurotestXE 2,5 kV is a multifunctional measuring instrument which apart from all the necessary functions
for complete installation safety testing according to IEC/EN 61557 performs insulation resistance measurement with the
test voltage up to 2,5 kV (measuring range is up to 20 G) and enables diagnostic test by PI and DAR indexes calculation.
Besides, the MI 3102H BT EurotestXE 2,5 kV enables on-line voltage monitoring, phase sequence testing, earth resistance
measurement, illuminance measurement and TRMS current measurement. EurotestXE 2,5 kV is equipped with integrated
characteristics of fuses and RCDs for PASS / FAIL evaluation of test results. All the results can be quickly saved and refer-
enced on the instrument and then downloaded via the EuroLink PRO software (included in the standard set) to the com-
puter for evaluation and report generation after testing.
TECHNICAL DATA:
Instrument EurotestXE 2,5 kV
Plug commander, 1.5 m
2.5 kV test lead, 2 x 1.5 m
Test lead, 3 x 1.5 m
Earth test set, 3-wire, 20 m (test lead, 4 m;
2 x test lead, 20 m; 2 x test rod)
Power supply adapter + 6 NiMH recharge-
able batteries, size AA
PC Software EuroLink PRO
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
RS232 - PS/2 cable
USB cable
Soft carrying neck belt
Soft carrying bag
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
Function Measuring range Resolution Accuracy
CONTINUITY
Test Current 7 mA 2-wire
0.00 ... 19.99
20.0 ... 1999
0.1
1
(5 % of r. + 5 digits)
Test Current 200 mA 2-wire
0.00 ... 19.99
20.0 ... 99.9
100.0 ... 1999
0.01
0.1
1
(3 % of r. + 3 digits)
(5 % of r.)
(5 % of r.)
INSULATION
RESISTANCE
Test Voltage 50/100/250 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
100.0 M ... 199.9 M
0.01 M

0.1 M
(5 % of r. + 3 digits)
(10 % of r.)
(20 % of r.)
Test Voltage 500/1000 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
200 M ... 999 M
0.01 M
0.1 M
1 M
(5 % of r. + 3 digits)
(5 % of r.)
(10 % of r.)
Test Voltage 2500 V
0.00 M ... 19.99 M
20.0 M ... 199.9 M
200 M ... 999 M
1.00 G ... 19.99 G
0.01 M
0.1 M
0.1 M
0.01 G
(5 % of r. + 3 digits)
(5 % of r.)
(10 % of r.)
(10 % of r.)
INSULATION
ANALAYSING
Calculation of PI, DAR, DD Only
for test voltage 500/1000/2500 V
0.01 M ... 9.99 M
10.0 M ... 100 M
0.01 M
0.1 M
(5 % of r. + 2 digits)
(5 % of r.)
RCD
Contact voltage
0.00 V ... 19.99 V
20.0 V ... 99.9 V
0.1 V
(-0%/15 %) of r. 10 digits
(-0%/15 %) of r.
Trip out time
0.00 ms ... 40.0 ms
0.0 V ... max.time
0.1 ms
1 ms
3 ms
Trip out current
0.2xIN ... 1.1xIN (AC)
0.2xIN ... 1.5xIN (A) IN 30 mA)
0.2xIN ... 2.2xIN (A) IN <30 mA)
0.05xIN 0.1 IN
IMPEDANCE
Zline L-L, L-N Ipsc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
Zloop L-PE, Ipfc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
VOLTAGE
TRMS 0 550 V 1 V (2 % of r. + 2 digits)
Frequency
0.00 Hz .. 9.99 Hz
10.0 Hz ... 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of r. + 1 digits)
CURRENT
TRMS, AC with
A 1018
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
(5 % of r. + 5 digits)
(3 % of r. + 3 digits)
(3 % of r.)
TRMS, AC with
A 1019
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
idicative
(5 % of r.)
(3 % of r.)
TRMS, AC/DC with A 1391,
range=40A
0.00 A ... 1.99 A
2.00 A ... 19.99 A
20.0 A ... 39.9 A
0.01 A
0.01 A
0.1 A
(3 % of r. + 3 digits)
(3 % of r.)
(3 % of r.)
TRMS, AC/DC with A 1391,
range = 300A
0.00 A ... 19.99 A
20.0 A ... 39.9 A
40.0 A ... 299.9 A
0.01 A
0.1 A
0.1 A
idicative
(3 % of r. + 5 digits)
EARTH
RESISTANCE
3 wire
0.00 M ... 19.99
20.0 M ... 199.9
200.0 M ... 9999
0.01
0.1
1
(5 % of r. + 5 digits)
2 clamp
0.00 M ... 19.99
20.0 M ... 30.0
30.1 M ... 99.9
0.01
0.1
0.1
(10 % of r. + 10 digits)
(20 % of r.)
(30 % of r.)
Specic earth resistance
0.0 m 99.9 m
100 m ... 999 m
1.00 mk ... 9.99 km
10.0 mk ... 99.9 km
0.1 m
1 m
0.01 km
0.1 km
(5 % of r.) for Re 1 1999k
(10 % of r.) for Re 2 k 19.99k
(20 % of r.) for Re > 20 k
ILLUMI-
NANCE
Type B
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(5 % of r. + 2 digits)

(5 % of r.)
Type C
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(10 % of r. + 3 digits)

(10 % of r.)
GENERAL
Power supply 9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port BT, USB, RS232
Weight 1.3 kg
Size ( l x h x w ) 230 x 103 x 115 mm
Electrical Installation Safety Electrical Installation Safety
1. 20 1. 21 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
STANDARDS:
Functionality:
EN 61557
DIN 5032
Other reference standards for testing:
IEC/EN 60364-4-41;
EN 61008;
EN 61009;
BS 7671;
AS/NZ 3017;
CEI 64.8;
HD 384;
VDE 413
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1;
EN 61010-031
EN 31010-2-030
EN 31010-2-032
Built-in charger and rechargeable bat-
teries as standard accessory.
RCD auto: automated RCD testing
procedure.
Bluetooth communication with PC,
Android tablets and smart phones via
built-in BT.
PC SW EuroLink PRO for downloading
of test results and report creation.
EuroLink Android APP, data manage-
ment tool (option).
APPLICATION:
Initial and periodic testing of domestic
and industrial installations.
Testing of single and multiphase sys-
tems.
Testing of TT, TN and IT earthing sys-
tems.
Medical installation testing.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage
from 50 V to 1000 V;
Continuity of PE conductors with 200
mA DC test current with polarity change;
Continuity of PE conductors with 7 mA
test current without RCD tripping;
Line/Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
Power and harmonics;
RCD testing (general and selective, type
AC, A, F, B, B+);
Earth resistance (3-wire and 2-clamps
method);
Specic earth resistance with Ro-adapt-
er (option);
TRMS leakage and load currents (op-
tion);
First fault leakage current (ISFL);
Testing of Insulation Monitoring Devices
(IMDs);
Illumination (option).
KEY FEATURES:
Predened mini AUTO SEQUENCE

s:
Auto TT (U, Zln, Zs, Uc);
Auto TN/RCD (U, Zln, Zs, Rpe);
Auto TN (U, Zln, Zlpe, Rpe);
Auto IT (U, Zln, Isc, Is, IMD).
Power measurements and harmonics
analysis.
Built-in help screens for referencing
on site.
Built-in fuse tables for automatic
evaluation of the line / loop impedance
result.
On-line voltage monitoring: monitors
all 3 voltages in real-time.
Polarity swap: automatic polarity re-
versal on continuity test.
Trip Lock function: loop impedance
test without tripping the RCD.
MI 3102 BT EurotestXE
MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety
tests according to IEC/EN 61557. It supports AUTO SEQUENCE

testing of the TN, TT and IT earthing systems. ISFL measure-


ments and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase
sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE
is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results. All the results can
be quickly saved and referenced on the instrument and then downloaded via the EuroLink PRO software (included in the
standard set) to the computer for evaluation and report generation after testing.
TECHNICAL DATA:
Instrument EurotestXE
Plug commander, 1.5 m
Test lead, 3 x 1.5 m
Earth test set, 3-wire, 20 m (test lead, 4 m;
2 x test lead, 20 m; 2 x test rod)
Power supply adapter + 6 NiMH recharge-
able batteries, size AA
PC Software EuroLink PRO
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
RS232 - PS/2 cable
USB cable
Soft carrying neck belt
Soft carrying bag
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
CONTINUITY
Test Current 7 mA 2-wire
0.00 ... 19.99
20.0 ... 1999
0.1
1
(5 % of r. + 5 digits)
Test Current 200 mA 2-wire
0.00 ... 19.99
20.0 ... 99.9
100.0 ... 1999
0.01
0.1
1
(3 % of r. + 3 digits)
(5 % of r.)
(5 % of r.)
INSULATION
RESISTANCE
Test Voltage 50/100/250 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
100.0 M ... 199.9 M
0.01 M

0.1 M
(5 % of r. + 3 digits)
(10 % of r.)
(20 % of r.)
Test Voltage 500/1000 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
200 M ... 999 M
0.01 M
0.1 M
1 M
(5 % of r. + 3 digits)
(5 % of r.)
(10 % of r.)
RCD
Contact voltage
0.00 V ... 19.99 V
20.0 V ... 99.9 V
0.1 V
(-0%/15 %) of r. 10 digits
(-0%/15 %) of r.
Trip out time
0.00 ms ... 40.0 ms
0.0 V ... max.time
0.1 ms
1 ms
3 ms
Trip out current
0.2xIN ... 1.1xIN (AC)
0.2xIN ... 1.5xIN (A) IN 30 mA)
0.2xIN ... 2.2xIN (A) IN <30 mA)
0.05xIN 0.1 IN
IMPEDANCE
Zline L-L, L-N Ipsc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
Zloop L-PE, Ipfc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
VOLTAGE
TRMS 0 550 V 1 V (2 % of r. + 2 digits)
Frequency
0.00 Hz .. 9.99 Hz
10.0 Hz ... 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of r. + 1 digits)
CURRENT
TRMS, AC with
A 1018
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
(5 % of r. + 5 digits)
(3 % of r. + 3 digits)
(3 % of r.)
TRMS, AC with
A 1019
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
idicative
(5 % of r.)
(3 % of r.)
TRMS, AC/DC with A 1391,
range=40A
0.00 A ... 1.99 A
2.00 A ... 19.99 A
20.0 A ... 39.9 A
0.01 A
0.01 A
0.1 A
(3 % of r. + 3 digits)
(3 % of r.)
(3 % of r.)
TRMS, AC/DC with A 1391,
range = 300A
0.00 A ... 19.99 A
20.0 A ... 39.9 A
40.0 A ... 299.9 A
0.01 A
0.1 A
0.1 A
idicative
(3 % of r. + 5 digits)
EARTH
RESISTANCE
3 wire
0.00 M ... 19.99
20.0 M ... 199.9
200.0 M ... 9999
0.01
0.1
1
(5 % of r. + 5 digits)
2 clamp
0.00 M ... 19.99
20.0 M ... 30.0
30.1 M ... 99.9
0.01
0.1
0.1
(10 % of r. + 10 digits)
(20 % of r.)
(30 % of r.)
Specic earth resistance
0.0 m 99.9 m
100 m ... 999 m
1.00 mk ... 9.99 km
10.0 mk ... 99.9 km
0.1 m
1 m
0.01 km
0.1 km
(5 % of r.) for Re 1 1999k
(10 % of r.) for Re 2 k 19.99k
(20 % of r.) for Re > 20 k
ILLUMI-
NANCE
Type B
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(5 % of r. + 2 digits)

(5 % of r.)
Type C
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(10 % of r. + 3 digits)

(10 % of r.)
GENERAL
Power supply 9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port BT, USB, RS232
Weight 1.3 kg
Size ( l x h x w ) 230 x 103 x 115 mm
Electrical Installation Safety Electrical Installation Safety
1. 22 1. 23 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
EN 61008;
EN 61009;
BS 7671;
AS/NZ 3017;
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1;
EN 61010-031
EN 31010-2-030
EN 31010-2-032
EuroLink Android APP, data manage-
ment tool (option).
APPLICATION:
Initial and periodic testing of domestic
and industrial installations.
Testing of single and multiphase sys-
tems.
Testing of TT and TN supply systems.
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN 60364-4-41;
MEASURING FUNCTIONS:
Insulation resistance with DC voltage
from 50 V to 1000 V;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7 mA
test current without RCD tripping;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A, F);
Earth resistance (3-wire method).
KEY FEATURES:
Predened mini AUTO SEQUENCE

s:
Auto TT (U, Zln, Zs, Uc);
Auto TN/RCD (U, Zln, Zs, Rpe);
Auto TN (U, Zln, Zlpe, Rpe).
Built-in help screens for referencing
on site.
Built-in fuse tables for automatic
evaluation of the line / loop impedance
result.
On-line voltage monitoring: moni-
tors all 3 voltages in real-time.
Polarity swap: automatic polarity re-
versal on continuity test.
Trip Lock function: loop impedance
test without tripping the RCD.
Built-in charger and rechargeable bat-
teries as standard accessory.
RCD auto: automated RCD testing
procedure.
Bluetooth communication with PC,
Android tablets and smart phones via
built-in BT.
PC SW EuroLink PRO for downloading
of test results and report creation.
MI 3100 SE EurotestEASI
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a
complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line
voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated
characteristics of fuses and RCDs for PASS / FAIL evaluation of test results. All the results can be quickly saved and refer-
enced on the instrument and then downloaded via the EuroLink PRO software (included in the standard set) to the com-
puter for evaluation and report generation after testing.
TECHNICAL DATA:
Instrument EurotestEASI
Schuko-plug test cable, 1.5 m
Test lead, 3 x 1.5 m
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
Power supply adapter + 6 NiMH recharge-
able batteries, size AA
RS232 - PS/2 cable
USB cable
Soft carrying neck belt
Soft carrying bag
PC Software EuroLink PRO
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
CONTINUITY
Test Current 7 mA 2-wire
0.00 ... 19.99
20.0 ... 1999
0.1
1
(5 % of r. + 5 digits)
Test Current 200 mA 2-wire
0.00 ... 19.99
20.0 ... 99.9
100.0 ... 1999
0.01
0.1
1
(3 % of r. + 3 digits)
(5 % of r.)
(5 % of r.)
INSULATION
RESISTANCE
Test Voltage 50/100/250 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
100.0 M ... 199.9 M
0.01 M

0.1 M
(5 % of r. + 3 digits)
(10 % of r.)
(20 % of r.)
Test Voltage 500/1000 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
200 M ... 999 M
0.01 M
0.1 M
1 M
(5 % of r. + 3 digits)
(5 % of r.)
(10 % of r.)
RCD
Contact voltage
0.00 V ... 19.99 V
20.0 V ... 99.9 V
0.1 V
(-0%/15 %) of r. 10 digits
(-0%/15 %) of r.
Trip out time
0.00 ms ... 40.0 ms
0.0 V ... max.time
0.1 ms
1 ms
3 ms
Trip out current
0.2xIN ... 1.1xIN (AC)
0.2xIN ... 1.5xIN (A) IN 30 mA)
0.2xIN ... 2.2xIN (A) IN <30 mA)
0.05xIN 0.1 IN
IMPEDANCE
Zline L-L, L-N Ipsc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
Zloop L-PE, Ipfc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
VOLTAGE
TRMS 0 550 V 1 V (2 % of r. + 2 digits)
Frequency
0.00 Hz .. 9.99 Hz
10.0 Hz ... 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of r. + 1 digits)
EARTH
RESISTANCE
3 wire
0.00 M ... 19.99
20.0 M ... 199.9
200.0 M ... 9999
0.01
0.1
1
(5 % of r. + 5 digits)
2 clamp
0.00 M ... 19.99
20.0 M ... 30.0
30.1 M ... 99.9
0.01
0.1
0.1
(10 % of r. + 10 digits)
(20 % of r.)
(30 % of r.)
Specic earth resistance
0.0 m 99.9 m
100 m ... 999 m
1.00 mk ... 9.99 km
10.0 mk ... 99.9 km
0.1 m
1 m
0.01 km
0.1 km
(5 % of r.) for Re 1 1999k
(10 % of r.) for Re 2 k 19.99k
(20 % of r.) for Re > 20 k
GENERAL
Power supply 9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port BT, USB, RS232
Weight 1.3 kg
Size ( l x h x w ) 230 x 103 x 115 mm
READY
Electrical Installation Safety Electrical Installation Safety
1. 24 1. 25 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
MEASURING FUNCTIONS:
Insulation resistance with DC voltage
from 50 V to 1000 V;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current without RCD tripping;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A, F);
Earth resistance (3-wire metod).
KEY FEATURES:
Built-in help screens for referencing
on site.
Built-in fuse tables for automatic
evaluation of the line / loop impedance
result.
On-line voltage monitoring: moni-
tors all 3 voltages in real-time.
Polarity swap: automatic polarity re-
versal on continuity test.
Trip Lock function: loop impedance
test without tripping the RCD.
Built-in charger and rechargeable bat-
teries as standard accessory.
RCD auto: automated RCD testing
procedure.
APPLICATION:
Initial and periodic testing of domestic
and industrial installations.
Testing of single and multiphase sys-
tems.
Testing of TT and TN supply systems.
MI 3100 s EurotestEASI
MI 3100 s EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a basic
set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 s EurotestEASI enables on-line voltage
monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated charac-
teristics of fuses and RCDs for PASS / FAIL evaluation of test results.
TECHNICAL DATA:
Instrument EurotestEASI
Schuko-plug test cable, 1.5 m
Test lead, 3 x 1.5 m
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
Power supply adapter + 6 NiMH recharge-
able batteries, size AA
Soft carrying neck belt
Soft carrying bag
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
CONTINUITY
Test Current 7 mA 2-wire
0.00 ... 19.99
20.0 ... 1999
0.1
1
(5 % of r. + 5 digits)
Test Current 200 mA 2-wire
0.00 ... 19.99
20.0 ... 99.9
100.0 ... 1999
0.01
0.1
1
(3 % of r. + 3 digits)
(5 % of r.)
(5 % of r.)
INSULATION
RESISTANCE
Test Voltage 50/100/250 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
100.0 M ... 199.9 M
0.01 M

0.1 M
(5 % of r. + 3 digits)
(10 % of r.)
(20 % of r.)
Test Voltage 500/1000 V
0.00 M ... 19.99 M
20.0 M ... 99.9 M
200 M ... 999 M
0.01 M
0.1 M
1 M
(5 % of r. + 3 digits)
(5 % of r.)
(10 % of r.)
RCD
Contact voltage
0.00 V ... 19.99 V
20.0 V ... 99.9 V
0.1 V
(-0%/15 %) of r. 10 digits
(-0%/15 %) of r.
Trip out time
0.00 ms ... 40.0 ms
0.0 V ... max.time
0.1 ms
1 ms
3 ms
Trip out current
0.2xIN ... 1.1xIN (AC)
0.2xIN ... 1.5xIN (A) IN 30 mA)
0.2xIN ... 2.2xIN (A) IN <30 mA)
0.05xIN 0.1 IN
IMPEDANCE
Zline L-L, L-N Ipsc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
Zloop L-PE, Ipfc
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 k ... 9.99 k
0.01
0.1
1
10
(5 % of r. + 5 digits)

(10 % of r.)
VOLTAGE
TRMS 0 550 V 1 V (2 % of r. + 2 digits)
Frequency
0.00 Hz .. 9.99 Hz
10.0 Hz ... 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of r. + 1 digits)
EARTH
RESISTANCE
3 wire
0.00 M ... 19.99
20.0 M ... 199.9
200.0 M ... 9999
0.01
0.1
1
(5 % of r. + 5 digits)
2 clamp
0.00 M ... 19.99
20.0 M ... 30.0
30.1 M ... 99.9
0.01
0.1
0.1
(10 % of r. + 10 digits)
(20 % of r.)
(30 % of r.)
Specic earth resistance
0.0 m 99.9 m
100 m ... 999 m
1.00 mk ... 9.99 km
10.0 mk ... 99.9 km
0.1 m
1 m
0.01 km
0.1 km
(5 % of r.) for Re 1 1999k
(10 % of r.) for Re 2 k 19.99k
(20 % of r.) for Re > 20 k
GENERAL
Power supply 9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category CAT II / 1000 VDC; CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port BT, USB, RS232
Weight 1.3 kg
Size ( l x h x w ) 230 x 103 x 115 mm
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN 60364-4-41; EN 61008; EN 61009; BS 7671; AS/NZ 3017
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1; EN 61010-031; EN 31010-2-030; EN 31010-2-032
Electrical Installation Safety Electrical Installation Safety
1. 26 1. 27 Accessories: page 1.58 Accessories: page 1.58
MI 3125BT EurotestCOMBO
APPLICATION:
Initial and periodic testing of domestic
and industrial installations;
Testing of single and multiphase systems;
Testing of TT and TN systems.
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
VDE 0413; IEC/EN 61008; IEC/EN 61009;
IEC/EN/HD 60364; HD 384; BS 7671;
IEC/TR 60755; CEI 64.8; AS/NZ 3760;
AS/NZ 3018
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety:
IEC/EN 61010-1; IEC/EN 61010-031
Trip Lock function: Zs (RCD) function
performs a loop impedance test with-
out tripping the RCD.
Multi-system testing: tests on single
and multiphase TT and TN systems.
Built-in charger & rechargeable bat-
teries: unit has a built-in charging cir-
cuit and comes complete with a set of
rechargeable NiMH batteries.
RCD auto: automated RCD testing pro-
cedure signicantly reduces test time.
B type RCD testing is supported.
BT connectivity: it enables BT com-
munication with Android tablets and
smart phones via built-in BT.
PC SW Eurolink PRO included in the
the standard set enables download-
ing of test results and parameters and
creation of test reports.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A and B);
Earth resistance (3-wire method).
KEY FEATURES:
LED Pass/Fail indicators: two LED in-
dicators for PASS / FAIL evaluation of
test results are placed on both sides
of the LCD
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Earth resistance measurement: in-
strument performs 3-wire earth resist-
ance testing with two additional rods.
Built-in fuse tables: this unique fea-
ture allows automatic evaluation of the
line / loop impedance compared to the
regulations.
Online voltage monitoring: monitors
all 3 voltages in real-time.
Upgradeable: if changes occur to the
regulations, upgrades can be made to
the rmware to keep the instrument
up to date.
Polarity swap: automatic polarity re-
versal on continuity test.
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, reading up to 1000 M.
The MI 3125BT EurotestCOMBO performs all the necessary tests for installation safety testing on TT and TN systems. The
large graphic display with backlight offers easy reading of results, indications, measurement parameters and messages.
Two LED Pass/Fail indicators are placed on both sides of the LCD. MI 3125BT EurotestCOMBO contains integrated charac-
teristics of fuses and RCDs (including B type) for the evaluation of test results. Each test has its own individual help screen
describing how to connect the instrument into the installation and how to perform a measurement. All the results can
be quickly saved and referenced on the instrument and then downloaded via the EuroLink PRO software, included in the
standard set, to the computer for evaluation and report generation after testing. MI 3125BT EurotestCOMBO performs
continuity, insulation, RCD, loop, line, voltage, frequency, earth resistance testing and phase sequence tests required by
the EN 61557 standard.
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U = 50, 100, 250 VDC:
R: 0.00 M 19.99 M
20.0 M 99.9 M
100.0 M 199.9 M
U = 500 VDC, 1 kVDC:
R: 0.00 M 19.99 M
20.0 M 99.9 M
200 M 999 M
0.01 M
0.1 M
0.1 M
0.01 M
0.1 M
1 M
(5 % of reading + 3 digits)
10 % of reading
20 % of reading
(5 % of reading + 3 digits)
5 % of reading
10 % of reading
Continuity 200 mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(3 % of reading + 3 digits)
5 % of reading
5 % of reading
Low resistance continuity
measurement, test current 7 mA
(Continuous measurement)
0.0 19.9
20 1999
0.1
1
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Loop impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Voltage drop 0.0 % 99.9 % 0.1 % Consider accuracy of line impedance
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency
0.00 Hz 9.99 Hz
10.0 Hz 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of reading + 1 digits)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0 % / +15 %) of reading 10 digits
(-0 % / +15 %) of reading
- Trip-out time
0 ms 40.0 ms
0 ms max. time
0.1 ms
0.1 ms
1 ms
3 ms
- Trip-out current
0.2 x IN 1.1 x IN (AC type)
0.2 x IN 2.2 x IN (A type, IN < 30 mA)
0.2 x IN 1.5 x IN (A type, IN 30 mA)
0.2 x IN 2.2 x IN (B type)
0.05 x IN
0.05 x IN
0.05 x IN
0.05 x IN
0.1 x IN
0.1 x IN
0.1 x IN
0.1 x IN
Earth resistance (EN 61557-5)
0.00 19.99
20.0 199.9
200 9999
0.01
0.1
1
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 140 x 80 x 230 mm
Weight 1.0 kg
Instrument EurotestCOMBO
Set of carrying straps
Test lead, 3 x 1.5 m
Schuko-plug test cable, 1.5 m
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
USB cable
RS232 - PS/2 cable
PC SW EuroLink PRO
Short instruction manual
Instruction manual and handbook on CD
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
MULTIFUNCTIONAL INSTALLATION TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 28 1. 29 Accessories: page 1.58 Accessories: page 1.58
MI 3125 EurotestCOMBO
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
VDE 0413; IEC/EN 61008; IEC/EN
61009; IEC/EN/HD 60364; HD 384; BS
7671; IEC/TR 60755; CEI 64.8; AS/NZ
3760; AS/NZ 3018
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety:
IEC/EN 61010-1; IEC/EN 61010-031
teries: unit has a built-in charging cir-
cuit and comes complete with a set of
rechargeable NiMH batteries.
RCD auto: automated RCD testing pro-
cedure signicantly reduces test time.
APPLICATION:
Initial and periodic testing of domestic
and industrial installations;
Testing of single and multiphase sys-
tems;
Testing of TT and TN systems.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC, A).
KEY FEATURES:
LED Pass/Fail indicators: two LED in-
dicators for PASS / FAIL evaluation of
test results are placed on both sides
of the LCD.
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Built-in fuse tables: this unique fea-
ture allows automatic evaluation of the
line / loop impedance compared to the
regulations.
Online voltage monitoring: monitors
all 3 voltages in real-time.
Upgradeable: if changes occur to the
regulations, upgrades can be made to
the rmware to keep the unit up to
date.
Polarity swap: automatic polarity re-
versal on continuity test.
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, reading up to 1000 M.
Trip Lock function: Zs (RCD) function
performs a loop impedance test with-
out tripping the RCD.
Multi-system testing: tests on single
and multiphase TT and TN systems.
Built-in charger & rechargeable bat-
The MI 3125 EurotestCOMBO is the appropriate instrument for the installation safety testing on TT and TN systems. The
large graphic display with backlight offers easy reading of results, indications, measurement parameters and messages.
Two LED Pass / Fail indicators are placed on both sides of the LCD. EurotestCOMBO contains integrated characteristics of
fuses and RCDs for the evaluation of test results. The handling of the instrument is designed to be as simple and clear
as possible. Each test has its own individual help screen describing how to connect the instrument into the installation
and how to perform a measurement. MI 3125 EurotestCOMBO performs continuity, insulation, RCD, loop, line, voltage,
frequency and phase sequence tests required by the EN 61557 standard.
MULTIFUNCTIONAL INSTALLATION TESTERS
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U = 50, 100, 250 VDC:
R: 0.00 M 19.99 M
20.0 M 99.9 M
100.0 M 199.9 M
U = 500 VDC, 1 kVDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 999 M
0.01 M
0.1 M
0.1 M
0.01 M
0.1 M
1 M
(5 % of reading + 3 digits)
10 % of reading
20 % of reading
(5 % of reading + 3 digits)
5 % of reading
10 % of reading
Continuity 200 mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(3 % of reading + 3 digits)
5 % of reading
5 % of reading
Loop impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Voltage drop 0.0 % 99.9 % 0.1 % Consider accuracy of line impedance
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency
0.00 Hz 9.99 Hz
10.0 Hz 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of reading + 1 digits)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0 % / +15 %) of reading 10 digits
(-0 % / +15 %) of reading
- Trip-out time
0 ms 40.0 ms
0 ms max. time
0.1 ms
0.1 ms
1 ms
3 ms
- Trip-out current
0.2 x IN 1.1 x IN (AC type)
0.2 x IN 2.2 x IN (A type, IN < 30 mA)
0.2 x IN 1.5 x IN (A type, IN 30 mA)
0.05 x IN
0.05 x IN
0.05 x IN
0.1 x IN
0.1 x IN
0.1 x IN
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
Dimensions 140 x 80 x 230 mm
Weight 1.0 kg
Instrument EurotestCOMBO
Test lead, 3 x 1.5 m
Schuko-plug test cable
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
Set of carrying straps
Short Instruction manual
Instruction manual on CD
Handbook on CD
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
MULTIFUNCTIONAL INSTALLATION TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 30 1. 31 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
MI 2086 Eurotest 61557
APPLICATION:
Initial and periodic testing of domestic
and industrial installations;
Testing of single and multiphase systems;
Testing of TT and TN systems.
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; IEC/EN 61008;
IEC/EN 61009; IEC/EN/TR 60755; AS/
NZ 3018; CEI 64.8; HD 384; BS 7671;
VDE 0413
Electromagnetic compatibility:
EN 50081 - 1; EN 50082 - 1
Safety: IEC/EN 61010-1; IEC/EN 61010-
031; IEC/EN 61010-2-032
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Polarity swap: automatic polarity re-
versal on continuity test.
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, reading up to 1000 M.
Trip Lock function: RLOOP function
performs a loop resistance test with-
out tripping the RCD.
RCD auto: automated RCD testing
procedure signicantly reduces test
time.
PC SW EuroLink LITE included in the
the standard set enables download-
ing of test results and parameters and
creation of test reports.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
Line impedance;
Loop impedance;
Loop resistance with Trip Lock function;
Voltage and frequency;
Phase sequence;
RCD testing (general and
selective, type AC and A);
Earth resistance
(4-wire method,
one clamp method,
two clamps method);
Specic earth resistance;
TRMS leakage and load currents;
Overvoltage protection devices testing;
Illumination (option);
Tracing the installations (option);
High resolution loop impedance (m).
KEY FEATURES:
Fuse location: function enables the lo-
cating of fuses / wires / faults with the
help of the optional A 1005 Fuse locator.
Earth resistance measurement: in-
strument performs 4-wire earth re-
sistance measurement with two ad-
ditional rods; 4-wire earth resistance
measurement in combination with an
additional current clamp; earth resist-
ance measurement with 2 current
clamps without breaking the loop and
4-wire specic earth resistance meas-
urement.
Downloadable: downloads via RS232
cable directly to the PC with the help
of the software included in the stand-
ard set.
The MI 2086 Eurotest 61557 performs complete testing of electrical installations and enables a number of additional fea-
tures including TRMS current measurement, 4-wire / one clamp / two clamps earth resistance and 4-wire specific earth
resistance measurements, illumination measurement and fuse / fault locator function. The handling of the instrument is
simple and clear. Each test has its own individual help screen describing how to connect the instrument into the instal-
lation and how to perform a measurement. All the results can be saved on the instrument and then downloaded with
the help of the EuroLink LITE software to the computer for evaluation and report generation after testing. The MI 2086
Eurotest 61557 performs continuity, insulation, RCD, loop, line, voltage, frequency, earth resistance and phase sequence
testing required by the EN 61557 standard.
MI 2086 ST
Instrument Eurotest 61557
Plug commander, 1.5 m
Test lead, 3 x 1.5 m
Crocodile clip
Test probe, 2 pcs (blue, black)
RS232 cable
PC Software EuroLink LITE
Set of carrying belts
Soft carrying bag
Instruction manual
Handbook on CD
Calibration certicate
MI 2086 EU
MI 2086 ST
Current clamp A 1018 (low range, leakage)
Test lead, 4 m
PC Software EuroLink PRO
STANDARD SET:
Function Measuring range Resolution Accuracy
Insulation resistance
(EN 61557-2)
U = 50, 100 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
U= 250, 500, 1000 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
200 M 1000 M
0.001 M
0.01 M
0.1 M
0.001 M
0.01 M
0.1 M
1 M
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
10 % of reading
Continuity of PE conductor
with polarity change, test current 200
mA (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(2 % of reading + 2 digits)
3 % of reading
3 % of reading
Low resistance continuity measure-
ment, test current 7mA (continuous
measurement)
0.0 199.9
200 2000
0.1
1
(3 % of reading + 3 digits)
(3 % of reading + 3 digits)
Loop impedance (EN 61557-3)
0.00 19.99
20.0 199.9
200 2000
0.01
0.1
1
(2 % of reading + 3 digits)
Line impedance (EN 61557-3)
0.00 19.99
20.0 199.9
200 2000
0.01
0.1
1
(2 % of reading + 3 digits)
Voltage 0 V 440 V 1 V (2 % of reading + 2 digits)
Phase sequence (EN 61557-7) 1.2.3 or 2.1.3.
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Contact voltage UC
0.0 V 9.99 V
10.0 V 100.0 V
0.01 V
0.1 V
(-0 / +10 %) of reading 0.2 V
(-0 / +10 %) of reading
- Trip-out time 0 ms 500 ms 1 ms 3 ms
- Trip-out current
0.2 x IN 1.1 x IN

(AC type)
0.2 x IN 1.5 x IN (A type)
0.05 x IN
0.05 x IN
0.1 x IN
0.1 x IN
Earth resistance (EN 61557-5) (4-wire
method; 4-wire method with one
clamp)
0.00 19.99
20.0 199.9
200 1999
2.00 k 19.99 k
0.01
0.1
1
10
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
5 % of reading
Earth resistance, two clamps method
0.00 19.99
20.0 100.0
0.01
0.1
(10 % of reading + 2 digits)
20 % of reading
Current TRMS
0.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 99.9 A
100 A 200 A
0.1 mA
1 mA
0.01 A
0.1 A
1 A
(5 % of reading + 3 digits)
5 % of reading
5 % of reading
5 % of reading
5 % of reading
Varistor Test 0 V 1000 V 1 V (5 % of reading +10 V)
Illuminance (Type B)
0.00 lux 19.99 lux
20.0 lux 199.9 lux
200 lux 1999 lux
2.00 klux 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
(5 % of reading + 2 digits)
Power supply 4 x 1.2 V rechargeable batteries or 4 x 1.5 V alkaline batteries, type C
Over voltage category CAT III / 300 V; CAT II / 600 V
Protection class Double insulation
COM port RS232
Dimensions 265 x 110 x 185 mm
Weight 2.1 kg
TECHNICAL DATA:
MI 2086 EU
MULTIFUNCTIONAL INSTALLATION TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 32 1. 33 Accessories: page 1.58 Accessories: page 1.58
MULTIFUNCTIONAL INSTALLATION TESTERS
MI 2088 Earth - Insulation Tester
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364;
AS/NZ 3018;
CEI 64.8;
HD 384;
BS 7671;
VDE 0413
Electromagnetic compatibility:
EN 50081-1; EN 50082-1
Safety:
IEC/EN 61010-1; IEC/EN 61010-031;
IEC/EN 61010-2-032
Insulation range: wide range of insula-
tion test voltages from 50 V to 1000 V,
resistance measuring range up to 30 G.
PC SW EarthLink included in the the
standard set enables downloading of
test results and parameters and crea-
tion of test reports.
APPLICATION:
Initial and periodic testing of domestic
and industrial installations;
Testing of single and multiphase sys-
tems;
Testing of TT and TN systems.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
Voltage;
Earth resistance (4-wire method, one
clamp method, two clamps method).
Specic earth resistance;
TRMS leakage and load currents (op-
tion);
Overvoltage protection devices test-
ing.
KEY FEATURES:
Earth resistance measurement: in-
strument performs 4-wire earth re-
sistance measurement with two ad-
ditional rods; 4-wire earth resistance
measurement in combination with an
additional current clamp; earth resist-
ance measurement with 2 current
clamps without breaking the loop and
4-wire specic earth resistance meas-
urement.
Downloadable: downloads via RS232
cable directly to the PC with the help
of the software included in the stand-
ard set.
Polarity swap: automatic polarity re-
versal on continuity test.
The MI 2088 Earth - Insulation Tester is a high professional, multifunctional, portable test instrument intended for carrying
out earth resistance, insulation resistance and continuity of protection conductors measurements. The Earth - Insulation
Tester enables 4-wire earth resistance measuring method, 4-wire earth resistance method in combination with one clamp,
two clamps earth resistance measurement, 4-wire specific earth resistance measurement and TRMS current measurement.
Besides the breakdown voltage of overvoltage protection devices can be checked by the instrument. All the results can be
saved on the instrument and then downloaded with the help of the EarthLink software to the computer for evaluation
and report generation after testing. The MI 2088 Earth - Insulation Tester performs earth resistance, continuity, insulation
and voltage measurements required by the EN 61557 standard.
MI 2088 ST
Instrument Earth-Insulation Tester
Test lead, 2 x 1,5 m
Soft carrying bag
RS232 cable
Test probe, 2 pcs (red, black)
Crocodil clip
PC Software EarthLink
Instruction manual
Handbook on CD
Calibration certicate
MI 2088 - 20 m
MI 2088 ST
Earth test set, 20 m (test lead, 4 x 1 m; 2
x test lead, 20 m; 2 x test lead, 4.5 m; 4 x
earth test rod; small soft carrying bag)
MI 2088 - 50 m
MI 2088 ST
Earth test set, 50 m (test lead, 4 x 1 m; 2 x
test lead, 50 m; 2 x test lead, 1 m; 2 x test
lead, 4.5 m; 4 x earth test rod; soft carrying
bag)
STANDARD SET:
TECHNICAL DATA:
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U 250 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
200 M 1999 M
2.00 G 19.99 G
20.0 G 29.9 G
U < 250 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
0.001 M
0.01 M
0.1 M
1 M
10 M
100 M
0.001 M
0.01 M
0.1 M
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(1 % of r. / 1 G + 2% of r. + 2 digits)
(1 % of r. / 1 G + 2% of r. + 2 digits)
(1 % of r. / 1 G + 2% of r. + 2 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Continuity 200 mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(2 % of reading + 2 digits)
3 % of reading
3 % of reading
Low resistance continuity
measurement, test current 7 mA
(continuous measurement)
0.0 199.9
200 1999
0.1
1
(3 % of reading + 3 digits)
(3 % of reading + 3 digits)
Earth resistance 4-wire method
0.00 19.99
20.0 199.9
200 1999
2.00 k 19.99 k
0.01
0.1
1
10
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
5 % of reading
Earth resistance 4-wire method
with one current clamp
0.00 19.99
20.0 199.9
200 999
1.00 k 1.99 k
0.01
0.1
1
10
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
2-clamp earth resistance measure-
ment
0.00 19.99
20.0 100.0
0.01
0.1
(10 % of reading + 2 digits)
20 % of reading
Specic earth resistance (EN 61557-5)
0.00 19.99
20.0 199.9
200 1999
2.00 k 19.99 k
20.0 k 199.9 k
200 k 999 k (a < 8 m)
200 k 1999 k (a 8m)
0.01
0.1
1
10
0.1 k
1 k
1 k
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
(2 % of reading + 3 digits)
5 % of reading
5 % of reading
5 % of reading
5 % of reading
TRMS Current
0.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 99.9 A
100 A 200 A
0.1 mA
1 mA
0.01 A
0.1 A
1 A
(5 % of reading + 3 digits)
5 % of reading
5 % of reading
5 % of reading
5 % of reading
Varistor Test 0 V 1000 V 1 V (5 % of reading + 10 V)
Power supply 4 x 1.2 V rechargeable batteries or 4 x 1.5 V alkaline batteries, type C
Over voltage category CAT III / 300 V; CAT II / 600 V
Protection class Double insulation
COM port RS232
Dimensions 265 x 110 x 185 mm
Weight 1.7 kg
MI 2088 - 50 m
MULTIFUNCTIONAL INSTALLATION TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 34 1. 35 Accessories: page 1.58 Accessories: page 1.58
Selection Guide for Single-functional Testers
SINGLE-FUNCTIONAL TESTERS
Part No.
MI 3121 MI 3122 MI 3123 MI 3110 MI 2126 MI 3103
Insulation / Continuity Z Line-Loop / RCD Earth / Clamp EurotestIM Earth 2-3 GigaOhm 1 kV
Features Description
INSULATION
Insulation resistance
Test voltage (VDC) 50 1000 250 1000
Insulation resistance measuring range up to 30 G up to 2 G
CONTINUITY AND
LOW RESISTANCE
MEASUREMENT
Continuity of PE conductor with automatic polarity change,
test current 200mA

Low resistance measurement (continuous measurement),
test current 7 mA.

LINE / LOOP
IMPEDANCE
Line impedance with Ipsc calculation
Loop impedance with Ipsc calculation
RCD Trip Lock loop impedance
Built-in fuse tables for PASS / FAIL evaluation
RCD TESTING
Contact voltage without RCD tripping
RCD trip-out time
RCD trip-out current with rising test current
Automatic testing of RCDs
RCD type (general and selective) A , AC
VOLTAGE,
FREQUENCY
AC voltage measurement
Online voltage monitor
Frequency measurement
PHASE SEQUENCE L1 - L2 - L3
EARTH, CURRENT
MEASUREMENTS
Earth resistance 3-(4-)wire method
Earth resistance 3-(4-)wire method with additional current clamp Option
Earth resistance measurement with 2 current clamps Option
Soil resistance measurement
TRMS current Option
IT EARTHING
SYSTEM SPECIFIC
MEASUREMENTS
Insulation Monitoring Devices (IMD) testing (IT systems)
First fault leakage current (ISFL) measurement (IT systems)
Predined mini Autosequences
OTHER
FEATURES
PASS / FAIL evaluation of test results
Touch electrode
Help menu
COMMUNICATION
PORTS
RS232
USB
MEMORY,
SOFTWARE
Memory
Number of memory levels / memory locations 2 / 1500 3 / 1500 3 / 1500 3 / 500
Professional PC SW Option Option Option
Advanced PC SW Option Option Option
GENERAL DATA
Safety category
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT IV / 50 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 300 V
Batteries 6 x AA 6 x AA 6 x AA 6 x AA 4 x C 4 x C
Built-in battery charger
Weight 850 g 930 g 850 g 1.31 410 g 490 g
Dimentions (mm) 140 x 80 x 230 140 x 80 x 230 140 x 80 x 230 230 x 103 x 115 280 x 70 x 80 280 x 70 x 80
SINGLE-FUNCTIONAL TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 36 1. 37 Accessories: page 1.58 Accessories: page 1.58
SINGLE-FUNCTIONAL TESTERS
IEC/EN/HD 60364;
AS/NZ 3018;
CEI 64.8;
HD 384;
BS 7671;
VDE 0413
Electromagnetic compatibility:
IEC/EN 61326-1;
IEC/EN 61326-2-2
Safety:
IEC/EN 61010-1;
IEC/EN 61010-031
APPLICATION:
Domestic dead circuit testing;
Industrial dead circuit testing;
Telecommunication systems testing;
Resistance measurements.
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
TRMS voltage and frequency.
KEY FEATURES:
Insulation range: wide range of insu-
lation test voltages from 50 V to 1000
V, measuring range up to 30 G.
Analogue scale and digital LCD:
measuring results are displayed both in
numeric and analogue representation.
Downloadable: downloads via RS232
or USB cable directly to the PC with
the help of the optional software.
Upgradeable: if changes occur to the
regulations upgrades can be made to
the rmware to keep the instrument
up to date.
Polarity swap: automatic polarity re-
versal on continuity test.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
ing circuit and comes complete with a
set of rechargeable NiMH batteries.
Custom limits: if limits are set on
insulation or continuity function then
large green and red lights of the LEDs
will indicate a PASS or FAIL evaluation
of test result.
Easy to use: large bright LCD display
and large buttons enable easy handling
of the instrument (even while wearing
gloves).
Magnetic holder: magnet for xing
instrument on metal surfaces enables
hands-free operation.
MI 3121 SMARTECInsulation / Continuity
The MI 3121 SMARTEC Insulation / Continuity is a new generation tester for dead testing of electrical installations. With
both an analogue and digital representation of the results, the instrument ensures accurate measurements up to 2000
on continuity and up to 30 G on insulation function. Configurable limits enable a PASS / FAIL evaluation of test results,
which is accompanied with the bright red and green indicator lights for comfortable use even in the dark conditions. The
MI 3121 is equipped with a built-in charger and has a magnetic holder in order to free up hands for testing. All the results
can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink
PRO Plus software for evaluation and professional report generation after testing. The MI 3121 SMARTEC Insulation /
Continuity performs continuity, insulation AC voltage and frequency measurement tests.
Large LCD screen with backlight and PASS /
FAIL indicators.
KEY FEATURES
Simple and fast manipulation.
Instrument Smartec Insulation / Continuity
Soft hand strap
Test lead, 2 x 1.5 m
Test probe, 2 pcs (black, red)
Crocodile clip, 2 pcs (black, red)
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Instruction manual on CD
Short instruction manual
Handbook on CD
Calibration certicate
STANDARD SET:
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U = 500, 1000 VDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 999 M
1.00 G 4.99 G
5.00 G 19.99 G
20.0 G 29.9 G
U = 50, 100, 250 VDC:
R: 0.00 M 19,99 M
20.0 M 99.9 M
100.0 M 199.9 M
0.01M
0.1M
1 M
10 M
10 M
100 M
0.01 M
0.1 M
0.1 M
(5 % of reading + 3 digits)
5 % of reading
5 % of reading
10 % of reading
20 % of reading
Indicator only
(5 % of reading + 3 digits)
10 % of reading
20 % of reading
Continuity 200 mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(3 % of reading + 3 digits)
5 % of reading
10 % of reading
Low resistance measurement with 7
mA test current (continuous measure-
ment)
0.0 19.9
20 1999
0.1
1
(5 % of reading + 3 digits)
10 % of reading
Voltage
0.0 V 99.9 V
100 V 550 V
0.1 V
1 V
(3 % of reading + 3 digits)
Frequency
0.00 Hz 19.99 Hz
20.0 Hz 199.9 Hz
200 Hz 500 Hz
0.01 Hz
0.1 Hz
1 Hz
(0.2 % of reading + 1 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 140 x 230 x 80 mm
Weight 0.85 kg
TECHNICAL DATA:
USB and RS232 communication ports.
SINGLE-FUNCTIONAL TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 38 1. 39 Accessories: page 1.58 Accessories: page 1.58
SINGLE-FUNCTIONAL TESTERS SINGLE-FUNCTIONAL TESTERS
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; IEC/EN 61008;
IEC/EN 61009; IEC/EN/TR 60755; AS/
NZ 3760; AS/NZ 3018; CEI 64.8; HD
384; BS 7671; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326-1;
IEC/EN 61326-2-2
Safety:
IEC/EN 61010-1; IEC/EN 61010-031
and large buttons enable easy handling
of the instrument (even while wearing
gloves).
Magnetic holder: magnet for xing
instrument on metal surfaces enables
hands-free operation.
APPLICATION:
Domestic and Industrial live circuit
testing;
Testing of single phase and 3-phase,
TT and TN systems.
MEASURING FUNCTIONS:
Line impedance;
Loop impedance;
Loop impedance with Trip Lock RCD
function;
TRMS voltage and frequency;
Phase sequence;
RCD testing (general and selective,
type AC and A).
KEY FEATURES:
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
LED Pass/Fail indicators: two LED in-
dicators for PASS / FAIL evaluation of
test results are placed on both sides
of the LCD.
Built-in fuse tables: this unique fea-
ture allows automatic evaluation of the
line / loop impedance compared to the
regulations.
Online voltage monitoring: monitors
all 3 voltages in real-time.
Downloadable: downloads via RS232
or USB cable directly to the PC with
the help of the optional software.
Upgradeable: if changes occur to the
regulations upgrades can be made to
the rmware to keep the instrument
up to date.
Trip Lock function: Zs (RCD) function
performs a loop impedance test with-
out tripping the RCD.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
ing circuit and comes complete with a
set of rechargeable NiMH batteries.
RCD auto: automated RCD testing pro-
cedure signicantly reduces test time.
Easy to use: large bright LCD display
MI 3122 SMARTECZ Line-Loop / RCD
The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains inte-
grated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows
the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS /
FAIL lights and help screens for each measurement make the handling of the instrument easy and clear. All the results can
be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO
Plus software for evaluation and professional report generation after testing. The MI 3122 SMARTEC Z Line-Loop / RCD
performs RCD, loop, line, AC voltage, frequency and phase sequence tests required by the EN 61557 standard.
Large LCD screen with backlight and PASS /
FAIL indicators.
Simple and fast manipulation.
Function Measuring range Resolution Accuracy
RCD testing (EN 61557-6) IN: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
- Scaling factor for IN x 0.5; x 1; x 2; x 5
- Contact voltage UC
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0%/+15%) of reading 10 digits
(-0%/+15%) of reading
- Trip-out current
(0.2 1.1) x IN (AC type)
(0.2 1.5) x IN (A type, IN 30 mA)
(0.2 2.2) x IN (A type, IN < 30 mA)
0.05 x IN
0.05 x IN
0.05 x IN
0.1x IN
0.1x IN
0.1x IN
- Trip-out time
0.0 ms 40.0 ms
0.0 ms max. time
0.1 ms
0.1 ms
1 ms
3 ms
Loop impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
100 999
1.00 k 9.99 k
0.01
0.1
1
10
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
10 % of reading
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency 15.0 Hz 499.9 Hz 0.1 Hz (0.2 % of reading + 1 digit)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 140 x 230 x 80 mm
Weight 0.93 kg

TECHNICAL DATA:
KEY FEATURES
Instrument Smartec Z Line - Loop / RCD
Soft hand strap
Schuko-plug test cable
Test lead, 3 x 1.5 m
Test probe, 3 pcs (blue, black, green)
Crocodile clip, 3 pcs (blue, black, green)
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Instruction manual on CD
Short instruction manual
Handbook on CD
Calibration certicate
STANDARD SET:
USB and RS232 communication ports.
SINGLE-FUNCTIONAL TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 40 1. 41 Accessories: page 1.58 Accessories: page 1.58
SINGLE-FUNCTIONAL TESTERS
APPLICATION:
Testing on TT and IT systems;
Testing sub-station earthing;
Lightning system testing.
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; AS/NZ 3018; CEI
64.8; HD 384; BS 7671; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety: IEC/EN 61010-1; IEC/EN 61010-
031; IEC/EN 61010-2-032
ing circuit and comes complete with a
set of rechargeable NiMH batteries.
Custom limits: the limits can be set on
any function, in that case large green
and red lights of the LEDs will indicate
a PASS or FAIL evaluation of test re-
sult.
Easy to use: large bright LCD display
and large buttons enable easy handling
of the instrument (even while wearing
gloves).
Magnetic holder: magnet for xing
instrument on metal surfaces enables
hands-free operation.
MEASURING FUNCTIONS:
Earth resistance, 4-wire method;
Earth resistance, 4-wire method with
one current clamp (option);
Earth resistance, two clamps method
(option);
Specic earth resistance;
TRMS current (option).
KEY FEATURES:
Earth resistance measurement: in-
strument performs standard 4-wire
earth resistance tests with two earth-
ing rods and specic earth resistance
measurement.
Selective earth resistance test: op-
tional 4-wire earth resistance measure-
ment in combination with an additional
current clamp is used for measuring
earth resistance of individual earthing
rods.
Contactless earth resistance test:
earth resistance measurement with 2
current clamps without breaking the
loop is intended for measuring resist-
ance of individual earthing rods and is
reccomended rst of all for urban ar-
eas.
Downloadable: downloads via RS232
or USB cable directly to the PC with
the help of the optional software.
Upgradeable: if changes occur to the
regulations upgrades can be made to
the rmware to keep the instrument
up to date.
Help screens: instrument comes com-
plete with built-in help screens for ref-
erencing on site.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
MI 3123SMARTEC Earth / Clamp
The MI 3123 SMARTEC Earth / Clamp is a new generation earth resistance tester with the ability to perform 4-wire earth
resistance measurement and 4-wire specific earth resistance measurement. With the optional A 1018 and A 1019 current
clamps the instrument can perform 4-wire earth resistance measurement with one current clamp, contactless earth resist-
ance testing with two clamps and TRMS current measurement up to 20 A. Configurable limits enable a PASS / FAIL evalu-
ation of test results. All the results can be saved on the instrument and then downloaded via the optional software for
evaluation and professional report generation after testing. The lightweight design, large bright LCD screen, built-in help
screens, optional downloading via RS232 or USB ports and overvoltage category CAT IV make the MI 3123 an incredible
earth resistance measuring instrument.
Large LCD screen with backlight and PASS /
FAIL indicators.
USB and RS232 communication ports.
Function Measuring range Resolution Accuracy
Earth resistance (4-wire method (EN
61557-5); 4-wire method with one cur-
rent clamp)
0.00 19.99
20.0 199.9
200 1999
2000 9999
0.01
0.1
1
1
(3 % of reading + 3 digits)
(3 % of reading + 3 digits)
5 % of reading
10 % of reading
Earth resistance (2 clamps method)
0.00 19.99
20.0 30.0
30.1 99.9
0.01
0.1
0.1
(10 % of reading + 10 digits)
20 % of reading
30 % of reading
Specic earth resistance (EN 61557-5)
0.0 m 99.9 m
100 m 999 m
1.00 km 9.99 km
10.0 km 99.9 km
>100 km
0.1 m
1 m
0.01 km
0.1 km
1 km
Calculated value, consider earth resist-
ance 4-wire method
TRMS Current
0.0 mA 99.9 mA
100 mA 999 mA
1.00 A 19.99 A
0.1 mA
1 mA
0.01 A
(3 % of reading + 3 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT IV / 50 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 140 x 230 x 80 mm
Weight 0.85 kg
TECHNICAL DATA:
Simple and fast manipulation.
KEY FEATURES
Instrument Smartec Earth / Clamp
Soft hand strap
Test lead, 4.5 m (blue)
Test lead, 4.5 m (red)
Test lead, 20 m (green)
Test lead, 20 m (black)
Earth test rod, 4 pcs
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Instruction manual on CD
Short instruction manual
Handbook on CD
Calibration certicate
STANDARD SET:
SINGLE-FUNCTIONAL TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 42 1. 43 Accessories: page 1.58 Accessories: page 1.58
MI 3110 EurotestIM
locations with generators;
Marines and ships;
Mines, other special locations;
Adjustment and calibrations of IMD
devices.
STANDARDS:
Functionality:
IEC/EN 61557
Other reference standards for testing:
EN 60364-4-41;
BS 7671;
AS/NZS 3017
Electromagnetic compatibility:
IEC/EN 61326-1;
IEC/EN 61326-2-2
Safety:
IEC/EN 61010 -1;
EN 61010-2-030;
EN 61010-031
MEASURING FUNCTIONS:
Voltage, frequency and phase se-
quence.
Line impedance and prospective short
circuit current.
Voltage drop.
First fault leakage current (ISFL).
Testing of insulation monitoring de-
vices (IMD).
KEY FEATURES:
AUTO SEQUENCE

: One single AUTO


SEQUENCE

with programmable lim-


its and sub-tests ensuring Safety on all
PASS bar-rier parameters.
Voltage monitor: IT System recogniz-
ing, Voltage Range and Voltage Bal-
ance.
ISFL test: ISFL Single Fault Leakage
current from Phase 1 and Phase 2 to
PE. Fuse Trip-out Ability Evaluation,
Line Impedance and Ipsc Prospective
Short Circuit Current.
IMD control: IMD Insulation / ELM
Earth Leakage / RCM Residual Current
Monitor Devices Control.
IMD adjust: Alarm Trigger or Trip-Out
Check and Adjust.
APPLICATION:
Safety and functionality on IT installa-
tions in industry, in hospitals;
Connection of portable power genera-
tors;
Fire ghting mobile equipment, gen-
erators and pumps;
Military vehicles and generators;
Police vehicles and generators;
Construction sites and Road mainte-
nance;
SAT and radio / TV broadcasting mo-
bile equipment;
Safety and functionality on IT installa-
tions on the airports, concert halls, fair
The MI 3110 EurotestIM is a perfect tool for testing of permanent integrated or portable Low Voltage Electrical Installa-
tions supplied by Generator or Transformer and protected by an IT earthing system. Designed for simple but efficient safe-
ty testing of Integrated IT Earthing System powered with LV Generator or Transformer! With a single, pre-programmed
AUTO SEQUENCE

with sub-tests and adjustable limits it is possible to perform all the necessary verifications of safety
limits of a specific LV IT installation.
Instrument MI 3110 EurotestIM
Soft carrying bag
Mains measuring cable
Test lead, 3 x 1.5 m
Test probe, 3 pcs
Crocodile clip, 3 pcs
Set of carrying straps
RS232-PS/2 cable
USB cable
Set of NiMH battery cells
Power supply adapter
PC software EuroLink PRO
Short instruction manual
Instruction manual on CD
Handbook on CD
Calibration Certicate
STANDARD SET:
TECHNICAL DATA:
Function Measuring range Resolution Accuracy
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency
0.00 Hz 9.99 Hz
10.0 Hz 499.9 Hz
0.01 Hz
0.1 Hz
(0.2 % of reading + 1 digit)
Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
Line impedance (EN 61557-3)
0.00 9.99
10.0 99.9
0.01
0.1
(5 % of reading + 5 digits)
Prospective short-circuit current
0.00 A 0.99 A
1.0 A 99.9 A
100 A 999 A
1.00 kA 99.99 kA
100 kA 199 kA
0.01 A
0.1 A
1 A
10 A
1000 A
Consider accuracy of line resistance
measurement
First fault leakage current (ISFL) 0.0 mA 19.9 mA 0.1 mA (5 % of reading + 3 digits)
Threshold indicative insulation resis-
tance
5 k 640 5 k
Indicative values
Up to 128 steps
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
Dimensions 230 x 103 x 115 mm
Weight 1.1 kg
TECHNICAL DATA:
Construction and Maintenance / Medical / Fire / Military / Industry / Audio and Video / Racing / Ships And Marina Places
KEY FEATURES
SINGLE-FUNCTIONAL TESTERS SINGLE-FUNCTIONAL TESTERS
Electrical Installation Safety Electrical Installation Safety
1. 44 1. 45 Accessories: page 1.58 Accessories: page 1.58
SINGLE-FUNCTIONAL TESTERS
The MI 2126 Earth 2/3 is a high quality, professional grade test instrument for performing three-wire earth resistance
measurements in accordance with European standard EN 61557-5, on which the estimation of earthing quality is based.
The equipment was designed and produced according to many years of experience of producing and dealing with earth
resistance and electric installation test equipment.
TECHNICAL DATA:
MEASURING FUNCTIONS:
Earth resistance, 3-wire method.
KEY FEATURES:
Earth resistance measurement: in-
strument performs standard 3-wire
earth resistance tests with two earth-
ing rods.
Easy to use: only 3 buttons control all
the operations of the test instrument
and instruction manual explains various
earth resistance measuring methods.
Portable: the MI 2126 is light and bat-
tery operated instrument and can be
easily placed with other test instru-
ments for moving between tested
items.
Reliable: reliable results even in the
presence of stray currents.
Repeatability: outstanding repeatabil-
ity of test results especially in the case
of high test probe resistance of various
earthing structures (e.g. asphalt, sand,
and stone).
APPLICATION:
3-wire earth resistance testing;
Testing single rod and multiple spiked
earthing networks.
STANDARDS:
Functionality:
IEC/EN 61557-1; IEC/EN 61557-5
Instrument Earth 2/3
Carrying strap
Test lead, 4.5 m (black)
Test lead, 15 m (red)
Test lead, 20 m (blue)
Earth test rod, 2 pcs
Instruction manual
Calibration certicate
STANDARD SET:
Function Measuring range Resolution Accuracy
Earth resistance
0.00 19.99
20.0 199.9
200 999
1.000 k 1.999 k
2.00 k 19.99 k
0.01
0.1
1
1
10
(2% of reading + 10 digits)
(2% of reading + 10 digits)
(2% of reading + 10 digits)
(2% of reading + 10 digits)
5% of reading
Power supply 4 x 1.5 V alkaline batteries, type C
Protection class Double insulation
Dimensions 280 x 70 x 80 mm
Weight 410 g
Other reference standards for testing:
IEC/EN/HD 60364; AS/NZ 3018;
CEI 64.8; HD 384; BS 7671; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326
Safety: IEC/EN 61010-1;
IEC/EN 61010-031
MI 2126 Earth 2/3 MI 3103 GigaOhm 1 kV
SINGLE-FUNCTIONAL TESTERS
The MI 3103 GigaOhm 1 kV tester is an easy to use installation tester with the ability to perform accurate resistance meas-
urements quickly and efciently. Features including AC voltage testing, robust design, easy to read display and rotary
switch (which can be used even while wearing gloves) make the MI 3103 Gigaohm 1 kV an extremely good value and
versatile instrument to use.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage;
Continuity of PE conductors with 200
mA test current with polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
Voltage.
KEY FEATURES:
Easy to use: 3 buttons and rotary func-
tion selector control all the operations
of the test instrument.
Insulation range: three different test
voltages (250, 500 and 1000 V), wide
maesuring range up to 2 G.
Polarity swap: automatic polarity re-
versal on continuity test.
Compensation of test leads (up to 5
) eliminates lead resistance.
APPLICATION:
Domestic installation dead testing.
Periodic installation testing.
STANDARDS:
Functionality: IEC/EN 61557-1, IEC/EN
61557-2, IEC/EN 61557-4, IEC/EN 61557-10,
Other reference standards for testing:
Instrument GigaOhm 1 kV
Carrying strap
Test lead with test probe, 2 m, (black)
Test lead with test probe, 2 m, (red)
Crocodile clip (black)
Instruction manual
Calibration certicate
STANDARD SET: TECHNICAL DATA:
Function Measuring range Resolution Accuracy
Insulation resistance
(EN 61557-2)
U = 500, 1000 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
> 200 M
U = 250 VDC:
R: 0.000 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
200 M 1999 M
0.001 M
0.01 M
0.1 M
1 M
0.001 M
0.01 M
0.1 M
1 M
(3% of reading + 3 digits)
(3% of reading + 3 digits)
(3% of reading + 3 digits)
10% of reading
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
15% of reading
Continuity 200 mA of PE
conductor with polarity
change (EN 61557-4)
0.11 19.99
20.0 199.9
200 1999
0.01
0.1
1
(3% of reading + 3 digits)
(3 % of reading + 3 digits)
5% of reading
Low resistance meas-
urement 7 mA (continu-
ous measurement)
0.0 199.9
200 999
1000 1999
0.1
1
1
(5% of reading + 3 digits)
10% of reading
10% of reading
Voltage 0 V 600 V 1 V (3% of reading + 3 digits)
Power supply 4 x 1.5 V alkaline batteries, type C
Overvoltage category CAT III / 300 V
Dimensions 280 x 70 x 80 mm Weight 490 g
IEC/EN/HD 60364; AS/NZ 3018;
CEI 64.8; HD 384; BS 7671; VDE 0413
Electromagnetic compatibility: IEC/EN
61326
Safety: IEC/EN 61010-1;
IEC/EN 61010-031
Electrical Installation Safety Electrical Installation Safety
1. 46 1. 47 Accessories: page 1.58 Accessories: page 1.58
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
MEASURING FUNCTIONS:
High precision line impedance;
High precision fault loop impedance;
Contact voltage.
KEY FEATURES:
Independence: instrument is designed
to work independantly or in conjunc-
tion with: MI 2086 Eurotest 61557, MI
3101 EurotestAT, MI 3105 EurotestXA
and MI 3321 MultiServicerXA.
Range widening: adapts the instruments
to read from 0.1 m up to 19.99 .
Multi-system testing: works on both
single phase and 3-phase systems
(115 V to 440 V).
IPSC and IPFC calculation: IPSC and IPFC
readings calculated up to 400 kA.
4-wire measurement for elimination of
voltage drop on measuring leads.
Comfortable carrying: all the acces-
sories are put in the strong, rugged,
durable case of the instrument.
LCD: Built-in LCD for standalone meas-
urements.
APPLICATION:
High accuracy loop and line measure-
ments;
Power transformer and motor winding
measurement.
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
A 1143 Euro Z 290 A
The A 1143 Euro Z 290 A is a professional portable high current impedance tester. It performs high precision line and high
precision fault loop impedance measurements in environments up to CAT IV / 310 V.
Function Measuring range Resolution Accuracy
High resolution Line / Loop
impedance measurement
0.1 m 199.9 m
200 m 1999 m
2.00 19.99
0.1 m
1 m
10 m
(5% of reading + 1 m)
(5% of reading + 1 m)
(5% of reading + 10 m)
Measuring voltage range 90 V 530 V
Maximum test current (at 230 V) 154 A (10 ms)
Maximum test current (at 400 V) 267 A (10 ms)
Maximum test current (at 530 V) 350 A (10 ms)
Contact voltage 0 V 100 V 1 V (10% of reading + 3 digits)
Power supply 4 x 1.5 V alkaline batteries, type C
Overvoltage category 310 V / CAT IV
Protection class Double insulation
Pollution degree 2
Dimensions 345 x 160 x 335 mm
Weight 5.0 kg
TECHNICAL DATA:
Instrument Euro Z 290 A
Test lead, 2-wire, 2 pcs
Test lead, black, 2 m
Test probe, red, 2 pcs
Crocodile clip, black, 3 pcs
Crocodile clip, red, 2 pcs
RS232 cable
RS232-PS/2 cable
Instruction manual
Calibration certicate
STANDARD SET:
IEC/EN/HD 60364; AS/NZ 3018;
CEI 64.8; BS 7671; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326-1; IEC/EN 61326-2-2
Safety: IEC/EN 61010-1;
IEC/EN 61010-031
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
MI 2093 Line Tracer
FUNCTIONS:
Tracing cables in walls, ceilings, oor
and ground;
Tracing live or voltage free cables;
Locating cable interruptions and short-
circuits in cables;
Locating concealed sockets and distri-
bution boxes;
Locating fuses and assignment to cir-
cuits;
Determining an individual wire in a
bundle of wires;
Tracing pipe installations and other
conductive loops.
KEY FEATURES:
Detection depth up to 2 m can be
achieved.
Works on both, energized and non-
energized systems.
The highly sensitive Receiver R10K de-
tects injected signal around the meas-
ured line or object.
Three levels of sensitivity adjustment:
low, middle and high. Each level can be
additionally precisely adjusted.
Dual, bar-graph and buzzer indicator
ensures indication in dark and noisy
environment.
APPLICATION:
Electrical installations testing;
Cable networks testing;
Pipe installations testing;
Telecommunication sytems testing.
The MI 2093 Line Tracer is an universal instrument intended for tracing hidden conductive paths under plasters in walls,
floors and ground or for determining one wire in a tuft of wires. Fuses or outlets belonging to a certain loop can be locat-
ed as well. Line Tracer helps the operator to resolve hidden line problems easily (short circuits, interruptions, breakages).
Transmitter T10K
Power supply 4 x 1.5 V alkaline or 4 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 300 V
Dimensions 80 x 50 x 150 mm
Weight 280 g
Receiver R10K
Power supply 1 x 9 V battery
Dimensions 45 x 450 x 210 mm
Weight 140 g
TECHNICAL DATA:
Transmitter T10K
Receiver R10K
Test lead for R10K with built-in resistor and
test probe, 1.5 m
Test lead for T10K, 1.5 m, 2 pcs
Special selective probe
Test probe, black, 2 pcs
Crocodile clip, black, 2 pcs
Soft carrying bag
Instruction manual
Calibration certicate
STANDARD SET: STANDARDS:
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1; IEC/EN 61010-031
Electrical Installation Safety Electrical Installation Safety
1. 48 1. 49 Accessories: page 1.58 Accessories: page 1.58
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
KEY FEATURES:
Adapter is used for performing 4-wire
specic earth resistance measure-
ments;
Designed for use in conjunction with
the MI 3101 Eurotest AT and MI 3105
EurotestXA;
The instrument comes complete with
4-wire test lead, 15 m red extension
lead, 2 earthing rods and carrying bag;
Instruction manual contains step by
step guide on how to perform the
measurement;
It is recommended to use A 1199 in
combination with 3-wire 20 m earth
test lead set (S 2026).
APPLICATION:
4-wire earth resistance measurement;
Specic earth resistance measure-
ment.
STANDARDS:
Functionality: IEC/EN 61557
Other reference standards for testing:
IEC/EN/HD 60364; AS/NZ 3018;
CEI 64.8; BS 7671; VDE 0413
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1
A 1199 -Adapter
The -Adapter is a special accessory intended for using only with METREL installation testers MI 3101 Eurotest
AT and MI 3105 EurotestXA. It is designed for measurement of specific earth resistance.
TECHNICAL DATA:
-adapter
Small soft carrying bag
Earth test rod, 2 pcs
Test lead, red, 15 m
Test lead 4 x 1,5 m
Instruction manual
Calibration certicate
STANDARD SET:
Power supply 4 x 1.5 V alkaline or 4 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT IV / 50 V
Dimensions 100 x 200 x 50 mm
Weight 390 g
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
CS 2099 Eurocheck
FUNCTIONS:
Insulation calibration with test voltage
up to 1000 V;
Calibration of low resistance and conti-
nuity functions;
Fault loop and trip-lock RCD imped-
ance functions calibration (all test
currents supported on Metrel instru-
ments);
Calibration of RCD trip-out time func-
tion;
Calibration of line impedance measur-
ing function;
Calibration of voltage and frequency;
PE test terminal functional verication;
Automatic polarity verication
APPLICATION:
On-site testing of installation measur-
ing instruments;
Occasional routine control of the safe-
ty testers.
STANDARDS:
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1
The CS 2099 Eurocheck is a professional, multifunctional field calibrator intended for use with installation test instru-
ments. Accuracy and functionality of all Metrel and most other manufacturers installation testers can be verified with
the Eurocheck. The CS 2099 Eurocheck can provide a simple field calibration of the most frequently used functions when
testing installations.
Instrument Eurocheck
Small soft carrying bag
Instruction manual
STANDARD SET:
TECHNICAL DATA:
Power supply 230 V, 50 / 60 Hz
Overvoltage category CAT II / 300 V
Dimensions 103 x 61 x 205 mm
Weight 780 g
Electrical Installation Safety Electrical Installation Safety
1. 50 1. 51 Accessories: page 1.58 Accessories: page 1.58
DEMONSTRATION BOARDS
MI 3088 PV Demonstration Board
KEY FEATURES:
With this demo board all electrical
tests according to EN 625446 can be
demonstrated: continuity, isolation,
open circuit voltage Uoc, short circuit
current Isc and polarity.
It simulates an I/V characteristic of a
PV module/string.
Simulated output of the irradiance and
temperature sensor.
Simulation of a DC/AC inverter with
one DC input and single phase output.
APPLICATION:
Presentation of testing of a PV system;
Demonstration of PV test equipment
by sales personnel.
Demonstration board MI 3088 simulates typical photovoltaic (PV) system with one PV module and DC/AC inverter. It repre-
sents a typical installation that consist of PV string, DC switch box , DC/AC inverter and one phase connection to the power
grid. It is intended for use preferably by sales personnel for demonstration of the measuring methods and procedures on DC
and partially on AC side of a PV system.
Demonstration board
Mains cable
PS2 male / male adapter
Test lead 1.5 m, black
Test lead 1.5 m, red
User manual
STANDARD SET:
TECHNICAL DATA:
Power supply 115 V/ 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
Dimensions 450 330 110 mm
Weight 12.5 kg
STANDARDS:
Functionality: EN 62446
Electromagnetic compatibility: EN 61326
Safety: EN 61010-1
MA 2067 Demonstration Board
KEY FEATURES:
65 different measurements in accord-
ance to EN 61557 are possible (in-
sulation resistance, continuity of PE
conductors, earth resistance, specic
earth resistance, line and loop imped-
ance, phase rotation, leakage current,
RCD testing, voltage and frequency).
19 different errors can be selected on
a lockable distributor.
Different types of RCD are integrated
for measurement of trip-out time, trip-
out current and contact voltage
Simulation of TT, TN and IT earth sys-
tems.
Possibility of connection to single
phase or 3-phase supply system.
Booklet with theory and exercises for
schools and training centers is includ-
ed in a standard set.
APPLICATION:
Education of students of electrotechni-
cal specialities;
Education and practical training of elec-
trical contractors about measurements
on low voltage electroinstallations;
Demonstration on how to use different
measurement instruments by sales
personnel.
Demonstration Board MA 2067 is an excellent demonstration and educational tool that simulates real conditions in low
voltage electrical installations. The Demonstration board consists of all significant elements of electrical installations like
RCDs of different types, fuses, PE equalization bars, 1-phase and 3-phase sockets, various consumers of electrical energy and
various grounding systems (TT, TN, IT). The MA 2067 Demonstration Board provides simulation of different types of faults in
electroinstallation. Complete testing and troubleshooting of the installation is possible by using suitable instruments.
Demonstration board
Jumper, 4 pcs
Board support for vertical use
Three phase to one phase adapter
1-phase mains cable
Instruction manual
Booklet with exercises
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
Power supply 230 V / 400 V, 50 Hz
Dimensions 680 x 450 mm (w x h)
Weight 12.5 kg
STANDARDS:
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1
DEMONSTRATION BOARDS
Electrical Installation Safety Electrical Installation Safety
1. 52 1. 53 Accessories: page 1.58 Accessories: page 1.58
DEMONSTRATION BOARDS
MI 3099 Demonstration Board
KEY FEATURES:
The board contains real elements of
electrical installation like RCD, mains
switch, automatic fuses, switches,
lamps, 1-phase and 3-phase mains test
outlet, N and PE collector.
All standardised testing methods can
be presented.
TN or TT system with or without RCD
can be simulated.
Possibility of connection to single
phase or 3-phase supply system.
Various Autosequence test procedures
are supported for demonstration of
testing safety by new EurotestAT and
EurotestXA.
Demonstration board is put in the
strong rugged case with a handle for
comfortable carrying.
APPLICATION:
Presentation of complete testing of
any electrical installation;
Demonstration of electrical installation
test equipment operation by sales per-
sonnel.
STANDARDS:
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1
Demonstration board MI 3099 simulates typical electrical installation usually met in individual houses or apartments
with important elements on switchboard and on circut site. Demonstration board is intended for use preferably by sales
personnel when demonstrating operation of electrical installation test equipment, especially the new Metrels electrically
installations safety testers with built-in AUTOSEQUENCE procedure.
Demonstration board
Jumper
Special probe, 3 pcs
Mains cable
Three phase to one phase adapter
Instruction manual
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
Power supply 230 V / 400 V, 50 Hz
Overvoltage category CAT II / 300 V
Dimensions 480 387 136 mm
Weight 5 kg
DEMONSTRATION BOARDS
MI 2166 Demonstration Board
KEY FEATURES:
A number of different measurements
in accordance to EN 61557 are possi-
ble (insulation resistance, continuity of
PE conductors, earth resistance (four-
lead and two clamp methods), specic
earth resistance, line and loop imped-
ance, phase rotation, load current, RCD
testing, contact voltage, etc.).
Real elements of electrical installation
are placed on the front panel like RCD,
ON/OFF switch with lamp, mains test
outlet and connection terminals.
All standardised testing methods can
be presented.
5 different errors can be preset by
fault switches.
TN or TT system can be simulated.
Demonstration board is put in the
strong rugged case with a handle for
comfortable carrying.
APPLICATION:
Presentation of complete testing of
any electrical installation;
Demonstration of electrical installation
test equipment operation by sales per-
sonnel.
STANDARDS:
Electromagnetic compatibility:
IEC/EN 61326
Safety:
IEC/EN 61010-1
Demonstration board MI 2166 simulates common electrical installation usually met in individual house or apartment.
Demonstration board is to be used preferably by sales personnel when demonstrating operation of electrical installation
test equipment. Various test methods supported by different test instruments can be presented.
Demonstration board
Jumper, 2 pcs
Mains cable
Instruction manual
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
Power supply 230 V, 50 Hz
Overvoltage category CAT II / 300 V
Dimensions 450 330 110 mm
Weight 3.56 kg
Electrical Installation Safety Electrical Installation Safety
1. 54 1. 55 Accessories: page 1.58 Accessories: page 1.58
EuroLink PRO and EuroLink PRO Plus
The EuroLink PRO / PRO Plus software works in conjunction with Metrels downloadable installation testers. The software
automatically nds the instrument and allows the test engineer to download test results saved on the instrument, review
the results, relocate test results (if required), print test reports and print installation structures for storing in the distribu-
tion board. With the more advanced Metrel installation testers, structures can be built with the software and uploaded
to the instrument for easy installation navigation while performing on-site testing. Additionally the EuroLink PRO Plus
software offers the ability to automatically generate professional PRO Plus Reports.
KEY FEATURES:
Automatic recognition of the instru-
ment: when connecting your instru-
ment to the PC it is automatically rec-
ognized by the software.
Simple graphical visualisation of the
installation structure: enables graphi-
cal representation of the tested instal-
lation which makes it easy to navigate
in the installation.
10-level structures: in conjunction
with MI 3105 and MI 3101 PC soft-
ware enables creating the electrical
installation structures with up to 10
levels and 4 levels for other models.
Rearranging of structures: the ele-
ments of the structure can be relocat-
ed and renamed.
Installation structures printing: struc-
tures can be printed and stored in the
distribution board for easier later iden-
tication of the installation elements.
Structures upload: the installation
structure can be created in advance
on the PC and then simply uploaded
to your tester MI 3108, MI 3109, MI
3105, MI 3101, MI 3102H CL, MI
3102H BT, MI 3102 BT, MI 3100 SE,
MI 3125 BT and MI 3125B.
Export of test results: test results in
text format can be exported to other
programs (MS Excel, MS Word).
Automatic PRO Test Report genera-
tion: enables automatic generation of
PRO Test Report (low, medium and
high detailed).
Automatic PRO Plus Test Report
generation (PRO Plus version only):
enables automatic generation of PRO
Plus Test Report which include visual
inspection of tested object and test re-
sults in tabular form.
Suport of EuroLink Android: suports
extended le format from EuroLink An-
droid App.
PC SW EuroLink PRO / PRO Plus is com-
patible with:
MI 3108, MI 3109, MI 3105, MI 3101,
MI 3102, MI 3102H CL, MI 3102H BT,
MI 3102 BT, MI 3100 SE, MI 3002,
MI 3125 BT, MI 3125B, MI 3121, MI
3121H, MI 3122 and MI 3123.
Key features of PRO Plus Test Reports:
Downloaded test results are automat-
ically inserted onto PRO Plus forms.
Allows to ll out visual inspection
form for tested fuse cabinet or earth-
ing system.
Automatically selects worst case test
results for form completion.
Easy test report generation and re-
viewing facilities.
Eurolink PRO Plus enables creation of
the following test reports:
PRO Plus Test Report
NICEIC certicates (UK)
ZVEH certicates (Germany)
SiNa certicates (Switzerland)
VE certicates (Austria)
HD 384 certicates (Greek)
KEHE certicates (Greek)
GOST R 50571 (Russia)
UNE 202008 certicates (Spain)
PASSWORD PROTECTION:
PC SW EuroLink PRO is password pro-
tected for the following instruments:
MI 3121,
MI 3121H,
MI 3122,
MI 3123.
PC SW EuroLink PRO Plus is password
protected for all Metrel installation test-
ers.
ORDERING INFORMATION:
A 1291 PC SW EuroLink PRO with
USB and RS232-PS/2 cable
A 1290 PC SW EuroLink PRO Plus
with USB and RS232-PS/2 cable
A 1292 Upgrade code EuroLink PRO to
EuroLink PRO Plus
PC SOFTWARE
Tree view installation structure can be easily rearranged by customer. PRO Test Report.
PRO Plus Test Report.
PC SOFTWARE
Electrical Installation Safety Electrical Installation Safety
1. 56 1. 57 Accessories: page 1.58 Accessories: page 1.58
A 1431 EuroLink Android
PC SOFTWARE
The EuroLink Android is a data management tool for android tablets and smart phones. It is used in the eld together
with Metrels Electrical Installation Safety testers to serve as a measurement pre- and post-processing tool. It also enables
the wireless communication between instrument and Android device on one side and bunch of wireless communication
methods between Android device and PC.
KEY FEATURES:
Create the Reports already at the site
of Testing!
Attach notes, Photographs, Audio or
Video Files!
Share the Reports or Send them to
your clients!
Create Structure of Electrical Installa-
tion at the site.
Upload Structure of Electrical Installa-
tion to your test instrument
Download measurement results to Eu-
roLink Android Application.
Transfer Data, Share les or Send
them through your Tablet or Smart
Phone Tools to your Ofce for further
manipulation.
It is compatible with EuroLink PRO and
EuroLinkPRO Plus PC software.
It supports Bluetooth dongle or built-
in BT enabling communication channel
between the below listed measuring
instruments and a smart phone or a
tablet with Android OS and installed
application EuroLink Android.
EuroLink Android is compatible with:
MI 3105 EurotestXA
(supported by BT dongle)
MI 3101 EurotestAT
(supported by BT dongle)
MI 3102 BT EurotestXE
MI 3102H BT EurotestXE
MI 3100 SE EurotestEASI
(supported by BT dongle)
MI 3125BT EurotestCOMBO
MI 3108 EurotestPV
(supported by BT dongle)
Transfer Data, Share les or Send them
through your Tablet or Smart Phone Tools
to your Ofce for further manipulation.
Create Structure of Electrical Installation
at the site.
READY
Supported by
BT dongle
Built-in BT
solution
A 1428 EuroLinkPV Android
PC SOFTWARE
The EuroLinkPV Android is a data management tool for android tablets and smart phones. It is used at the site of testing
together with Metrels Photovoltaic testers as a measurement pre- and post-processing tool. It enables the wireless
communication between instrument and Android device. With this application testing of PV is more comfortable and
effective.
KEY FEATURES:
View the results of the I/V measure-
ment in graphical or numerical form.
Compare the results with the nominal
values and characteristic.
Edit the module data stored in instrument
memory using the Android Keyboard.
Edit the module list stored in instru-
ment memory.
The module data can be selected from the
huge module Data Base delivered within
the EuroLinkPV Android application.
It supports Bluetooth dongle enabling
a communication channel between the
below listed measuring instruments
and a smart phone or a tablet with An-
droid OS and installed application Eu-
roLinkPV Android.
EuroLink Android is compatible with:
MI 3108 EurotestPV
(supported by BT dongle)
MI 3109 EurotestPV Lite
(supported by BT dongle)
READY
Supported by
BT dongle
Built-in BT
solution
Electrical Installation Safety Electrical Installation Safety
1. 58 1. 59 Accessories: page 1.58 Accessories: page 1.58
Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1143 Euro Z 290 A
Euro Z 290 A is the impedance tester
which enables line / loop impedance
measurements with an accuracy down to
0.1 m.

A 1199 Ro-adapter
Ro-adapter is intended for performing
earth resistance measurement in combi-
nation with installation safety tester.

A 1378
EurotestPV
Remote
PV remote unit for measurement and log-
ging of irradiance and temperature values

A 1384 PV Safety Probe
The PV safety probe can safely disconnect
the PV installation from the installation in
case of a permanent short circuit.

CS 2099 Eurocheck
Eurocheck is a professional multifunctional
eld calibrator intended for use with instal-
lation safety testers.

A 1160
Fast charger for 8
AA batteries with
a set of 6 NiMH
bat., type AA
Fast battery charger for up to 8 pieces of
AA rechargeable batteries, and a set of 6
pcs NiMH rechargeable batteries, type AA.

A 1169
Fast charger for
AA, C, D and 9 V
block batteries
Fast battery charger for up to 12 pcs AA, 6
pcs C or D rechargeable batteries, 4 pcs 9
V block batteries.

A 1083
Power supply
adapter with 6 pcs
NiMH batteries,
type AA
Battery charger and a set of 6 pieces of
rechargeable batteries, type AA.

A 1399 PV Reference Cell Irradiance sensor for PV measurements.
A 1400
PV Temperature
probe
Temperature probe for measurement of
PV module temperature.

A 1102
Luxmeter sensor,
type B
Luxmeter sensor, type B, for high-accura-
cy illuminance measurement.

A 1119
Luxmeter sensor,
type C
Luxmeter sensor, type C, for illuminance
measurement e.g. for general light condi-
tions testing.

Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1172
Luxmeter sensor,
type B (PS/2)
Luxmeter sensor, type B, for high-accu-
racy illuminance measurement e.g. for
emergency lightning inspection.

A 1173
Luxmeter sensor,
type C (PS/2)
Illuminance probe for light conditions
measurements with 0,1Lux resolution.

A 1005
Fuse / fault / cable
locator
Fuse / fault / cable locator is used for wire
tracing, fuse identication and fault nding
in low voltage electrical installations.

A 1191 Receiver R10K
Receiver R10K is used for wire tracing,
fuse identication and fault nding in low
voltage electrical installations.

A 1192
Selective probe for
R10K
Very sensitive inductive sensor serves for
contactless fuse and cable nding. To be
used with A 1191.

A 1067
Test lead for R10K,
1.5 m, with built-in
resistor
Test lead with probe enables fast and ac-
curate fuse nding and current circuit al-
location. To be used with A 1191.

A 1168
Plug commander
(for MI 3100)
Single phase schuko plug commander
with TEST and BACKLIGHT function keys
for fast and simple measurements on one
phase sockets.

A 1256
Plug commander
(straight cable)
Single phase schuko plug commander
with TEST and MEM function keys for fast
and simple measurements on one phase
sockets.

A 1170 Plug commander
Single phase schuko plug commander
with TEST and MEM function keys for fast
and simple measurements on one phase
sockets.

A 1272
Plug commander
(for Smartec)
Single phase schuko plug commander
with TEST and MEM function keys for fast
and simple measurements on one phase
sockets.

A 1314 Plug commander
Single phase, 3-wire, commander with
TEST and MEM function and RGB LED
indicator for easy insulation safety meas-
urements for use with MI 3108 and its
successors.

A 1401 Tip commander
Single phase, 3-wire, commander with
TEST and MEM function and RGB LED
indicator for easy insulation safety meas-
urements for use with MI 3108 and its
successors.

Electrical Installation Safety Electrical Installation Safety
1. 60 1. 61 Accessories: page 1.58 Accessories: page 1.58
Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1002 Tip commander
Single phase 2-wire commander with test
tip and START and SAVE function keys for
installation safety measurements.

A 1175
Tip commander
(for MI 3100)
Single phase 2-wire commander with test
tip and TEST and BACKLIGHT function
keys for installation safety measurements.

A 1176 Tip commander
Single phase 2-wire commander with test
tip and TEST and MEM function keys for
installation safety measurements.

A 1194
Tip commander,
3-wire (for MI
3100)
Single phase 3-wire commander with test
tip, TEST and BACKLIGHT function keys
for installation safety measurements.

A 1197
Tip commander,
3-wire
Single phase 3-wire commander with test
tip, TEST and MEM function keys for in-
stallation safety measurements.

A 1244
Tip commander,
2-wire (straight
cable)
Single phase 2-wire commander with test
tip, TEST and SAVE function keys for in-
stallation safety measurements.

A 1270
Tip commander
(for Smartec)
Single phase 2-wire commander with test
tip, TEST and MEM function keys for in-
stallation safety measurements.

A 1300
Tip commander,
3-wire (for
Smartec)
Single phase 3-wire commander with test
tip, TEST and MEM function keys for in-
stallation safety measurements.
-
A 1018
Current clamp (low
range, leakage)
High accuracy current clamp 1000 A / 1 A
with jaw opening 52 mm and xed 1.5 m
cable for both load and low range / leakage
current measurement and for earth resist-
ance measurement as well.

A 1019 Current clamp
Current clamp 1000 A / 1 A with jaw opening
52 mm for general current measurements
and in combination with A 1018 for earth
resistance measurement without breaking
the loop.

A 1068
Connection cable
for clamp, 1.5 m
Connection cable for connecting current
clamp on the instrument MI 2093.

A 1074
Mini current clamp
200 A / 0.2 A
Mini current clamp 200 A / 0.2 A with jaw
opening 15 mm for current measurement
in conned spaces.

Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1391
AC/DC Current
clamp
AC/DC Current Clamp with 40 and 300 A
range.

A 1011
Test lead, 3 x
1.5 m
3-wire test lead for measurements on sin-
gle or three phase electrical installations.

A 1021 Test lead, 4 x 1 m
4-wire test lead for measurements on
electrical installations.

A 1055
Test lead, 2 x
1.5 m
2-wire test lead for continuity and insula-
tion resistance measurements on electri-
cal installations.

A 1385 PV fused test lead
Test cable for simultaneous AC/DC power
and efciency measurements of PV invert-
ers.

S 2001
Earth test set,
4-wire, 20 m
Earth test set for earth resistance meas-
urement on distance up to 20 m; set in-
cludes: test lead, 4 x 1 m; test lead, 20 m,
2 pcs; test lead, 4 m, 2 pcs; earth spikes, 4
pcs; soft carrying bag.

S 2002
Earth test set,
4-wire, 50 m
Earth test set for earth resistance measure-
ment on distance up to 50 m; set includes:
test lead, 4 x 1 m; test lead, 50 m, 2 pcs;
test lead, 4 m, 2 pcs; test lead, 1 m, 2 pcs;
earth spikes, 4 pcs; carrying bag.

S 2041
Earth test set,
4-wire, 50 m (for
Smartec)
Earth test set for earth resistance meas-
urement on distance up to 50 m; set in-
cludes: test lead, 50 m, 2 pcs; test lead,
4 m, 2 pcs; test lead, 1 m, 2 pcs; earth
spikes, 4 pcs; soft carrying bag.

S 2026
Earth test set,
3-wire, 20 m
Earth test set for earth resistance meas-
urement on distance up to 20 m; set in-
cludes: test lead, 20 m, 2 pcs; test lead,
4.5 m; earth spikes, 2 pcs; soft carrying
bag.

S 2027
Earth test set,
3-wire, 50 m
Earth test set for earth resistance meas-
urement on distance up to 50 m; set in-
cludes: test lead, 50 m, 2 pcs; test lead,
4.5 m; test lead, 1 m, 2 pcs; earth spikes,
2 pcs; soft carrying bag.

S 2058
Insulation test
plates
Two in one: Test plates for measurement
of oor and wall insulation, 625 cm
2
(acc.
to EN 60364-6) and measurement of semi
conductivity, 2,5 kg, 65 mm (acc. to EN
61340-5-1).

A 1052
PC SW EuroLink
PRO (for MI 2086)
EuroLink PRO is a professional PC Soft-
ware which enables downloading, data
management and complete test report
preparation.

Electrical Installation Safety Electrical Installation Safety
1. 62 1. 63 Accessories: page 1.58 Accessories: page 1.58
Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1290
PC SW EuroLink
PRO Plus with
USB and RS232-
PS/2 cable
Professional PC Software EuroLink PRO
Plus enables downloading, data manage-
ment and complete test report prepara-
tion. Delivered with RS232-PS/2 and USB
communication cables.

A 1291
PC SW EuroLink
PRO with USB and
RS232-PS/2 cable
PC Software EuroLink PRO enables down-
loading and test results management and
printing of test reports. Delivered with
RS232-PS/2 and USB communication cables.

A 1292
Upgrade code
EuroLink PRO to
EuroLink PRO Plus
Password for upgrading standard PC soft-
ware EuroLink PRO to advanced PC SW
EuroLink PRO Plus with professional re-
port creation facility.

A 1431
EuroLink Android
APP
EuroLink Android APP
A 1012
Test lead, green,
4 m
Extension test lead for continuity meas-
urements.

A 1154
Test lead, black,
4 m
Extension test lead for earth and continuity
measurements.

A 1026
Test lead, red,
20 m
Extension test lead for continuity meas-
urements.

A 1153
Test lead, black,
20 m
Extension test lead for earth and continuity
measurements.

A 1164
Test lead, black,
50 m
Extension test lead for earth and continuity
measurements.

S 2009
Test lead set, 2 m,
4 pcs
Set of 4 test leads is intended for two
clamp earth resistance measurement to
connect current clamps on the instrument.

S 2012
Continuity test
lead, 10 m, 2 pcs
(red, black)
2 pieces of extension test lead for continu-
ity measurements.

S 2025
Test lead, 1.5 m,
2 pcs (black, red)
Connection leads for different measure-
ments.

Selection Guide for EIS Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1013
Crocodile clip,
black
Crocodile clip assures secure and perma-
nent contact during the measurement on
bus bars, xing screws, etc.

A 1064 Crocodile clip, red
Crocodile clip assures secure and perma-
nent contact during the measurement on
bus bars, xing screws, etc.

A 1309
Crocodile clip,
green
Crocodile clip assures secure and perma-
nent contact during the measurement on
bus bars, xing screws, etc.

A 1310 Crocodile clip, blue
Crocodile clip assures secure and perma-
nent contact during the measurement on
bus bars, xing screws, etc.

A 1014 Test probe, black
Test probe with 4 mm connection is suit-
able for performing measurements both in
mains outlets and in situations when no
schuko outlet is present.

A 1015 Test probe, blue
Test probe with 4 mm connection is suit-
able for performing measurements both in
mains outlets and in situations when no
schuko outlet is present.

A 1016 Test probe, red
Test probe with 4 mm connection is suit-
able for performing measurements both in
mains outlets and in situations when no
schuko outlet is present.

A 1062 Test probe, green
Test probe with 4 mm connection is suit-
able for performing measurements both in
mains outlets and in situations when no
schuko outlet is present.

A 1198
Magnetic contact
probe
Test probe with magnetic contact provides
reliable contact with metal surface during
the measurement.

A 1201
Insulated rod for
CONTINUITY
measurement
Insulated rod enables insulation resistance
and continuity measurement on hard-to-
reach objects, e.g. luminaries.

A 1202
Additional exten-
sion part for A
1201
Additional extension part for Insulated rod
for CONTINUITY measurement A 1201.

A 1006 Soft carrying bag
Large soft carrying bag for transport and
storage of test instrument and belonging
accessories.

Electrical Installation Safety Electrical Installation Safety
1. 64 1. 65 Accessories: page 1.58 Accessories: page 1.58
Option Not available
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
A 1289 Soft carrying bag
Large soft carrying bag for transport and
storage of test instrument and belonging
accessories.

A 1020
Small soft carrying
bag
Small soft carrying bag for transport and
storage of test instrument or accessories.

A 1271
Small soft carrying
bag
Small soft carrying bag for transport and
storage of test instrument or accessories.

A 1302
Set of carrying
straps
Set of carrying straps for carrying the
measuring instrument around the neck al-
lowing free hand use of the tester.

A 1303 Soft hand strap Soft hand strap for holding the instrument.
A 1245
Holder for com-
mander
Holder enables free hand operation with
the tester by xing the test commander
and other test cables when not in use.

A 1110
Three phase
adapter
3-phase test adapter for installation safe-
ty testing on 3-phase sockets type 16 A
3CEE.

A 1111
A 1215
(for
MI 2150)
Three phase
adapter with
switch
3-phase adapter with selection switch for
installation safety testing on 3-phase sock-
ets type 16 A 3CEE. The adapter allows
seamless switching between measure-
ments.

A 1171
RS232 / USB
adapter with 1 m
cable
RS232 / USB adapter for instruments with-
out USB comunication port.

A 1436 Bluetooth dongle
External Bluetooth adapter for wireless
connection between Metrels instruments
and Smart phones, tablets and PCs.

A 1017
Communication
cable RS232
RS232 interface cable for connecting the
instrument with the PC.

A 1105 Barcode scanner
Barcode scanner for identication of bar-
code labelled installation structure ele-
ments like sockets, switches, fuses,
switchboards, etc.

Selection Guide for EIS Accessories Selection Guide for EIS Accessories
Photo
Part
number
Description Target application
M
I

3
1
0
8
M
I

3
1
0
9
M
I

3
1
0
5
M
I

3
1
0
1
M
I

3
1
0
2
H

B
T
M
I

3
1
0
2

B
T
M
I

3
1
0
0

S
E
M
I

3
1
0
0

s
M
I

3
1
2
5

B
T
M
I

3
1
2
5
M
I

2
0
8
6
M
I

2
0
8
8
M
I

3
1
2
1
M
I

3
1
2
2
M
I

3
1
2
3
M
I

3
1
1
0
M
I

2
1
2
6
M
I

3
1
0
3
M
I

2
0
9
3
A

1
1
4
3
AM 1337 RFID Reader RFID reader
S 2055
Set of 2 at con-
tact clamps
Flat contact clamp with integrated fuse for
a fast and safe contact on at conductor
bars, eg. in low voltage installations. With
red-colored ring.

S 2056 RFID HGL
Flat contact clamp for a fast and safe con-
tact on at conductor bars, eg. in low volt-
age installations.

S 2057
Set 5 of crocodile
clips
Set of 3 black and 2 red crocodile clips,
which assures secure and permanent con-
tact during the measurement on bus bars,
xing screws, etc.

Option Not available
Accessories: page 2.31
Electrical Installation Safety
1. 66 Accessories: page 1.58
M
e
t
r
e
l

w
o
r
k
i
n
g

t
e
a
m

f
o
r

t
h
e

a
b
s
o
l
u
t
e

p
o
l
e

p
o
s
i
t
i
o
n
.
GOOD TO KNOW
High Voltage Insulation / Continuity / Earth 2 - 02
Selection Guide for CONTINUITY Insulation Testers 2 - 06
Selection Guide for HV Insulation Testers 2 - 07
EARTH TESTER
MI 3295 Step Contact Voltage Measuring System 2 - 08
CONTINUITY TESTERS
MI 3252 MicroOhm 100A 2 - 10
MI 3250 MicroOhm 10A 2 - 12
MI 3242 MicroOhm 2A 2 - 14
HIGH VOLTAGE INSULATION TESTERS
MI 3210 TeraOhmXA 10 kV NEW 2 - 16
MI 3200 TeraOhm 10 kV 2 - 18
MI 3201 TeraOhm 5 kV Plus 2 - 20
MI 2077 TeraOhm 5 kV 2 - 22
MI 3202 GigaOhm 5 kV 1 - 24
MI 3121H 2,5 kV Insulation / Continuity 2 - 26
PC SOFTWARE
HVLink PRO 2 - 28
DEMONSTRATION BOARD
MI 3299 HV demo BOX 2 - 30
Selection Guide for HV Accessories 2 - 31
H
i
g
h

V
o
l
t
a
g
e

I
n
s
u
l
a
t
i
o
n

/

C
o
n
t
i
n
u
i
t
y

/

E
a
r
t
h

H
i
g
h

V
o
l
t
a
g
e

I
n
s
u
l
a
t
i
o
n

R
e
s
i
s
t
a
n
c
e

D
i
a
g
n
o
s
t
i
c
s

/

A
c
c
u
r
a
t
e

L
o
w

R
e
s
i
s
t
a
n
c
e

M
e
a
s
u
r
e
m
e
n
t
s
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
High Voltage Insulation / Continuity / Earth
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 2 2. 3 Accessories: page 2.31 Accessories: page 2.31
GOOD TO KNOW GOOD TO KNOW
Find out more about Insulation meas-
urement techniques
Insulation is a material property and is
measured as insulation resistance. Char-
acteristics of insulation tend to change
through time, normally getting worse
by ageing. Various physical phenomena
have inuence on insulation character-
istics, like temperature, dirt, humidity,
mechanical and electrical stresses, high-
energy radiation, etc. Harsh installation
environments, especially those with
temperature extremes and / or chemical
contamination, cause further deteriora-
tion.
Safety, operability and reliability are the
most important parameters of electri-
cal device containing insulation and this
is the reason why insulation has to be
measured. Insulation is measured in the
initiating phase of electrical device and
also later during maintenance works or
repairing, and measurements are of sim-
ple and diagnostic type.
Basics of insulation measurements
According to Ohms law,
__ U
R
I=
the current does not depend on time.
But a simple measurement of insula-
tion resistance shows that the current
depends on time. The reasons for such
behavior of the current are different
phenomena in insulation material after
a voltage is applied. A typical insulation
model is presented in gure below.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Insulation resistance and capacitance model, partial and total currents
U Applied test voltage
Riss1 & Riss2 Surface leakage resistances
Riso Insulation resistance
Ciso Insulation capacitance
Rpi Polarization resistance
Cpi Polarization capacitance
HV, Step / Contact Voltage and Earth Resistance HV, Step / Contact Voltage and Earth Resistance
The total current Itot comprises of four
partial currents.
Itot Total current
IRiss Surface leakage current
IRiso Insulation leakage current
IRCpi Polarization absorption current
ICiso Capacitance charging current
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Typical current / time diagram for a real voltage source
In practice the insulation resistance
measurement instrument does not in-
clude an ideal voltage source. At the
start all available instrument power is
used to charge the capacitor Ciso for
short period. The voltage on connection
points drops because of this.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Current diagram for an ideal voltage source
When DC voltage is suddenly applied to
the insulation, the test current will start
at a high value, gradually decrease with
time, and nally level off to a stable val-
ue. The leakage current does not change
with time, and this current is the primary
factor on which the insulation quality
may be judged.
Types of insulation testing
Various types of insulation testing are used
to determine insulation characteristics.
DC voltage testing and AC voltage
testing AC testing
AC testing is more suitable for per-
forming withstanding or dielectric tests.
While DC test gives more qualitative pic-
ture about the tested insulation.
Spot reading test
This is the simplest and fastest way of
insulation resistance testing. Unfortu-
nately only one test, with no prior tests,
can be only a rough guide as to how
good or bad the insulation is. In this test
the instrument is connected across the
insulation of the tested item. A test volt-
age is applied for a xed period of time;
usually a reading is taken after 1 minute
as can be seen in gure.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Typical insulation resistance/time diagramfor a spot reading test
The spot reading test should only be
carried out when the insulation tempera-
ture is above the dew point.
METRELs hint:
The lower limit of insulation resistance
may often be established according to
the one mega-ohm rule:
Insulation resistance should be at least
1 M for each kilovolt of operating volt-
age, but not less than 1 M (e.g. a mo-
tor rated at 5 kV working voltage should
have a minimum resistance of 5 M).
Time rise method / polarization index
/ dielectric absorption ratio
When test voltage is applied a bad in-
sulation causes drop of the value R
iso

and the increasing in the insulation leak-
age current I
Riso
. The absorption current
is masked by a high insulation leakage
current. The insulation leakage current
stays at a fairly constant value and the
resistance reading stays low. A good
insulation shows continuous increasing
of the resistance over a period. This is
caused by the absorption that can be
clearly seen. The absorption effect lasts
far longer than the time required for
charging the capacitance of the insula-
tion.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Time diagrams of good and bad insulation tested with the
time-rise method
The result of this measurement is polari-
zation index (PI), which is dened as the
ratio of measured resistance in two time
slots (typically the ratio is 10 min value
to 1 min value at a continuous measure-
ment).
PI value Tested material status
1 - 1.5 Not acceptable (older types)
2 - 4
(typically 3)
Considered as good
insulation (older types)
4 (very good
insulation)
Modern type of good insulation systems
Typical values of polarization index
________ Rtot (10 min)
PI=
Rtot (1 min)
The results of this method dont depend
on temperature and the method can give
a conclusive information without com-
paring records of past tests.
Dielectric absorption ratio (DAR) is simi-
lar to the polarization index method. The
only difference are periods for capturing
the results which are usually 30 s (or 15
s) and 1 minute.
DAR value Tested material status
< 1 Bad insulation
1 DAR 1.25 Acceptable insulation
> 1.4 Very good insulation
Typical values for dielectric discharge
________ Rtot (1 min)
DAR=
Rtot (30 s)
Dielectric discharge
It is difcult to determine the polariza-
tion index if polarization absorption cur-
rent I
RCpi
is small compared to the others.
Rather than measuring the polarization
current during an insulation test, the di-
electric discharge (DD) test can be per-
formed. DD test is carried out after the
completion of the insulation resistance
measurement. Typically the insulation
material is left connected to the test volt-
age for 10 ... 30 min and then discharged
before the DD test is carried out. After
1 min a discharge current is measured
to detect the charge re-absorption of the
insulation material. A high re-absorption
current indicates contaminated insula-
tion (mainly based on moisture).
DD value Tested material status
> 4 Bad
2 - 4 Critical
< 2 Good
Values of dielectric discharge
Idis (1 min)
U Ciso
DD=
Idis (1 min)
discharging current measured 1 min after
the voltage was switched off
U test voltage
Ciso capacitance of tested object
Typical values of dielectric discharge
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
The current/time diagram of a good and bad insulation tested
with dielectric discharge method
The dielectric discharge test is very use-
ful for testing a multi-layer insulation.
Step voltage insulation resistance test
Testing with a voltage far below the one
expected in service often reveals mois-
ture and dirt in insulation, whereas ef-
fects of ageing or mechanical damage of
a fairly clean and dry insulation may not
be revealed at such low stress. The step
voltage method is very useful when test-
ing with an instrument that has a lower
test voltage than the rated test voltage
of the tested item. In other words, step
voltage test gives us useful results even
in case we are not able to stress insula-
tion with nominal electrical voltages.
The device under test is exposed to dif-
ferent test voltages that are applied in
steps. The voltage starts at the lowest
value and increases with dened steps
up to the highest level.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Typical measuring procedure for step voltage measurement
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Typical step voltage measurement results
The shape of the curve represents the
quality of insulation:
The resistance of a damaged insulation
will rapidly decrease.
A good insulation has approximately
constant resistance at all voltages.
Withstanding voltage test
The withstanding voltage test is one of
the basic insulation tests. Its principle
is very simple - the voltage is stressing
the device under test until the required
test time or breakdown of insulation is
reached.
The time gradient of increasing voltage,
maximum voltage and the time of maxi-
mum test voltage are very important
and depend on the type of device under
test. These parameters are dened in
adequate standards. The indication of a
breakdown is a sudden increase in the
current through insulation, beyond the
predened limit.
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Measuring procedure for withstanding voltage measure-
ment.
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 4 2. 5 Accessories: page 2.31 Accessories: page 2.31
GOOD TO KNOW GOOD TO KNOW
HV, Step / Contact Voltage and Earth Resistance HV, Step / Contact Voltage and Earth Resistance
0 t
Rins
Good
insulation
Bad
insulation
+
U
IRiss
IRiso IRCpi
Itot
ICiso
Cpi
Rpi
Riso
Riss1
Riss2
Ciso Guard
0 200 400 600 800 t (s)
0
10
20
30
40
A
Isf
ICiso
IRiso
IRiss
IRCpi
0 60 t (s)
Rins
spot
test
result
0 t (s)
0
Discharge of
Ciss
10 20 30 40 50 60 70
Discharging of
Cpi
Bad
insulation
Good
insulation
0 10 t (min)
Rtot Good insulation
Insulation contaminated with
dirt and moisture
0 t
0
U1
U2
U3
U4
T1 T2 T3 T4 T5
U5
0 200 400 600 800 t (s)
0
10
20
30
40
A
Itot
IRiso
IRiss
IRCpi
1
I tot
0 t
0
U
Ustart
Tslope Ttest
Ustop
0 t
0
U
Ustart
Varistor
breakedown
Defective
insulation
Ub
Measuring procedure for withstanding voltage measure-
ment.
Typical connections for:
Power cables
Measurement of insulation resistance of cable between one
conductor against other conductors including lead sheath
Measurement of insulation resistance of cable between one
conductor against other conductors and lead sheath using
the guard terminal to avoid leakage effects at the end of
cable
Measurement of insulation resistance of a cable between a
conductor and lead sheath
Control and communication cable
Measurement of insulation resistance between one lead of
communication cable against other leads and sheath
Measurement of insulation resistance of communication
cable using the guard terminal. Resistance is measured be-
tween a lead and sheath
Measurement of insulation resistance of communication
cable using the guard terminal. Resistance is measured be-
tween one lead and other leads
Home appliances and similar electrical
devices

Measurement of household device, protection class I and
class II
Induction motor

Measurement of insulation resistance of induction motor
between all three phases against metal enclosure
Power transformer
The simplest measurement of insulation resistance of trans-
former
Measurement of insulation resistance on one HV winding
against metal enclosure
Earthing
Correct earthing of exposed conductive
parts of the object assures that the volt-
age on them stays below dangerous
level in case of a fault. If fault happens a
fault current will ow through the earth-
ing electrode.
A typical voltage distribution occurs
around the electrode (the voltage fun-
nel). Fault currents close to power dis-
tribution objects (substations, distribu-
tion towers, plants) can be very high, up
to 200 kA. This can result in dangerous
step and contact voltages. If there are
underground metal connections (intend-
ed or unknown) the voltage funnel can
get atypical forms and high voltages can
occur far from the point of failure. There-
fore the voltage distribution in case of a
fault around this objects must be care-
fully analyzed.
Dangerous voltages on a faulty earthing system
Standard IEC 61140 denes following
maximum allowed time / contact volt-
age relations:
Maximumtime of exposure Voltage
> 5 s to UC 50 VAC or 120 VDC
< 0.4 s UC 115 VAC or 180 VDC
< 0.2 s UC 200 VAC
< 0.04 s UC 250 VAC
Maximum time durations vs fault voltage
For a longer exposure the touch volt-
ages must stay below 50 V.
During the measurement a test cur-
rent is injected into the earth through
an auxiliary probe. A higher injected
current improves the immunity against
spurious earth currents.
Step voltage measurement
The measurement of step voltage is
performed between two ground points
at a distance of 1 m. The 25 kg measur-
ing probes simulates the feet. The volt-
age between the probes is measured
by a voltmeter with an internal resist-
ance of 1 k that simulates the body
resistance.
Step voltage measurement
Contact voltage measurement
The measurement of contact voltage is
performed between an earthed acces-
sible metal part and ground. The volt-
age between the probes is measured
by a voltmeter with an internal resist-
ance of 1 k that simulates the body
resistance.
Contact voltage measurement
Earth resistance measurement
For the earthing resistance test a voltage
and current probe (serves as auxiliary
earth) are used. Because of the voltage
funnel it is important that the test elec-
trodes are placed correctly.
Earth resistance measurement
Specic earth resistance
For the specic earth resistance the
test current is injected through two cur-
rent probes (C1/H and C2/E).
The voltage probes S and ES must be
placed between the current probes
(equidistance a between probes must
be considered). Using different dis-
tances between the test probes means
that the material at different depths is
measured. By increasing the distances
a a deeper layer of ground material is
measured.
Specic earth resistance measurement
Low Resistance Measurement
Four-wire Kelvin method
When measuring resistance <20 it is
advisable to use a four-wire Kelvin meas-
urement technique for achieving high
accuracy. By using this type of meas-
urement conguration the test lead re-
sistance is not included in the measure-
ment, and the need for lead calibrating
and balancing is eliminated.
Typical connections for:
Circuit breaker connection
Bus bar connection
Connecting instrument to the measured device
The measuring current is passed through
the unknown resistance Rx using the C1
and C2 leads. The placing of these leads
is not critical but should always be out-
side the P1 and P2 leads. The Volt drop
across the Rx is measured across P1
and P2 and these should be placed ex-
actly at the points to be measured.
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 6 2. 7 Accessories: page 2.31 Accessories: page 2.31
Selection Guide for HV Insulation Testers Selection Guide for CONTINUITY Insulation Testers
Part No.
NEW MI 3210 MI 3200 MI 3201 MI 2077 MI 3202 MI 3121H
TeraOhmXA
10 kV
TeraOhm 10 kV
TeraOhm 5 kV
Plus
TeraOhm 5 kV GigaOhm 5 kV
Insulation/
Continuity
MEASUREMENTS
Test voltage range
50 VDC 10
kVDC
500 VDC 10
kVDC
250 VDC 5
kVDC
250 VDC 5
kVDC
250 VDC 5
kVDC
100 VDC 2.5
kVDC
Voltage steps 50 V 25 V 25 V 50 V
250 V; 500 V;
1 kV;
2.5 kV; 5 kV
100 V; 250 V;
500 V; 1 kV;
2.5 kV
Insulation resistance measuring
range
20 T 10 T 10 T 5 T 1 T 100 G
Calculation of DD, DAR, PI
Withstanding voltage test
Voltage ramp test
Leakage current measurement
Capacitance measurement
Short circuit / charge current 5 mA 5 mA 5 mA 1.4 mA 5 mA 3 mA
Voltage measurement AC / DC up to 600 V up to 600 V up to 600 V up to 600 V up to 600 V up to 550 V
OTHER FEATURES
Programmable timer
Automatic discharge after test
Graph R(t)
Bar graph
Auto adjustment function
Auto ranging
Audible warnings
Guard terminal
Shielded test leads Option
COMMUNICATION PORTS
USB/ RS232 / / / Option / / /
BLOETOOTH
MEMORY, SOFTWARE
Memory
Number of memory locations 1000 1000 1000 1000 1500
Software HVLink PRO
Option (HVLink
PRO)
Option (HVLink
PRO)
Option (Ter-
aLink)

Option (Eu-
roLink PRO)
GENERAL DATA
Display type Graphical LCD Graphical LCD Graphical LCD Graphical LCD Custom LCD Custom LCD
Backlight
Safety category CAT IV / 600 V CAT IV / 600 V CAT IV / 600 V CAT III / 600 V CAT IV / 600 V
CAT III / 600 V;
CAT IV / 300 V
Rechargeable batteries Option
Built-in battery charger
Low battery indication
Battery life (no load connected) 4 h at 10 kV 4 h at 10 kV 4 h at 5 kV 4 h at 5 kV 4 h at 5 kV 13 h
Weight 5.5 kg 5.5 kg 3 kg 2.1 kg 3 kg 850 g
Dimensions (mm) 345 x 160 x 335 345 x 160 x 335 310 x 130 x 250 265 x 110 x 185 310 x 130 x 250 140 x 80 x 230
Part No.
MI 3252 MI 3250 MI 3242
MicroOhm 100A MicroOhm 10A MicroOhm 2A
MEASUREMENTS
Measuring range 1 n ... 20 100 n ... 2 k 1 ... 200
No. of ranges 6 7 6
Current into load 2 m at 100 A 200 m at 10 A 1 at 2 A
Highest resolution 1 n 0.1 1
Basic accuracy 0.25 % 0.25 % 0.25 %
Test current 100 A, 50 A, 10 A, 1 A, 100 mA 10 A, 1 A, 100 mA, 10 mA, 1 mA 2 A, 100 mA, 10 mA
OTHER FEATURES
Measurement modes Single, Continuous
Single, Automatic, Inductive,
Continuous
Single, Automatic, Inductive,
Continuous
Test method 4-wire, unidirectional 4-wire, Bidirectional 4-wire, Bidirectional
Autoranging
PASS / FAIL indication
Temperature compensation
COMMUNICATION PORTS
RS232
USB
MEMORY, SOFTWARE
Memory
Number of memory locations 1000 / 2 levels 1000 1500
Software HVLink PRO HVLink PRO HVLink PRO
GENERAL DATA
Display type Graphical LCD Graphical LCD Graphical LCD
Backlight
Safety category
CAT IV / 50 V
CAT II / 300 V
CAT IV / 300 V
CAT II / 300 V
CAT IV / 300 V
CAT III / 600 V
Rechargeable batteries
Battery 12 V / 12 Ah 6 x NiMH, type HR14 6 x NiMH, type AA
Built-in battery charger
Low battery indication
Mains voltage
115 / 230 V AC, 50 / 60 Hz, 200
VA
90-260 V AC, 45-65 Hz, 50 W
Weight 11.8 kg 2.8 kg 0.8 kg
Dimensions (mm) 410 x 175 x 370 310 x 130 x 250 140 x 80 x 230
CONTINUITY TESTERS HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 8 2. 9 Accessories: page 2.31 Accessories: page 2.31
EARTH TESTER
MEASURING FUNCTIONS:
Step voltage;
Contact voltage;
Specic earth resistance;
Earth resistance.
KEY FEATURES:
Accurate: high accuracy of the meas-
urements due to a high current of up
to 50 A and effective suppression of
noise.
Noise immunity: excellent immunity
even against changing earth currents.
Autonomous Step Voltage meter:
no need for long potential leads; a few
meters can be used simultaneously.
Safe: high safety due to low output
voltage (55 V).
Low weight: the weight of the Station
is 29.5 kg only.
Memory: up to 1000 test results can
be saved into the 3-level internal mem-
ory of the system.
PC SW HVLink PRO included in the
standard set enables downloading and
analysis of results and printing of test
reports.
APPLICATION:
Measurement of protective earthing of:
Power stations;
Substations;
Distribution towers;
Other power systems.
STANDARDS:
Functionality:
RAT 2008;
HD 673 N4;
ANSI/IEEE Std 81;
EN 61557-5
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1; EN 61010-031
The MI 3295 Step Contact Voltage Measuring System is a voltage measuring system intended for testing and verication
of protective earthing of power stations, substation and other power systems. The system consists of Station for current
generation and autonomous voltage Meter. Due to high test current (up to 55 A) and effective noise cancellation the MI
3295 ensures very accurate and stable measurements of Step and Contact Voltages with the resolution down to 10 V. A
few voltmeters can be used simultaneously for faster analysis of voltage distribution around the tested object. All test
results and parameters can be saved into the instruments memory for further downloading, analysis and test report
printing with the help of the PC SW HVLink PRO.
Instrument MI 3295M
Instrument MI 3295S
Mains cable
Step voltage probe (25 kg), 2 pcs
Current earth spike
Potential earth spike
Current test lead, 50 m, black, 10 mm2,
with crocodile clip, on wheel
Current test lead, 10 m, black, 10 mm2,
with crocodile clip
Test lead, black, 2 x 3 m
Test lead, green, 10 m
Test lead, black, 1.5 m
Test lead, red, 50 m
Connection lead with crocodile clip, red, 1 m
Crocodile clip, 4 pcs
RS232 cable
USB cable
Soft carrying bag, 2 pcs
STANDARD SET:
Soft carrying neck belt
NiMH battery cells, type AA, 6 pcs
Power supply adapter
CD with instruction manual and PC SW
HVLink PRO
Instruction manual
Calibration certicate
MI 3295 Step Contact Voltage Measuring System
EARTH TESTER
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Step voltage, Contact voltage (meas-
uring range Um)
0.01 19.99 mV
20.0 199.9 mV
200 1999 mV
2.00 19.99 V
20.0 V 59.9 V
0.01 mV
0.1 mV
1 mV
0.01 V
0.1 V
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
(2 % of reading + 2 digits)
Step voltage, Contact voltage (calcu-
lated measuring range U)
0.0 199.9 V
200 999 V
0.1 V
1 V
calculated value*
Test current 55 A max
Test voltage < 55 V
Test frequency 55 Hz
Current
0.00 9.99 A
10.0 99.9 A
0.01 A
0.1 A
(3 % of reading + 5 digits)
(3 % of reading + 3 digits)
Resistance to earth
0.001 1.999
2.00 19.99
20.0 99.9
100.0 199.9
0.001
0.01
0.1
0.1
(2 % of reading + 5 digits)
(2 % of reading + 5 digits)
(2 % of reading + 5 digits)
5 % of reading)
Specic earth resistance
0.00 9.99 m
10.0 99.9 m
100 999 m
1.00 k 9.99 km
10.0 k 99.9 km
0.01 m
0.1 m
1 m
10 m
100 m
Calculated value, consider accuracy of
Resistance to earth function.
Open circuit voltage < 50 VAC
Test current < 7.5 A
Test frequency 55 Hz
STATION
Power supply 230 V / 50 or 60 Hz
Communication port RS232
Memory 1000 memory locations
Overvoltage category CAT II / 300 V
Measuring category CAT IV / 50 V
Protection degree IP 30
Display LCD with backlight (128 x 64 dots)
Dimensions 563 x 275 x 257 mm
Weight 29.5 kg
METER
Power supply 6 x 1.2 V rechargeable batteries, type AA
Communication ports USB, RS232
Memory 1500 memory locations
Measuring category CAT IV / 50 V
Protection degree IP 40
Display LCD with backlight (128 x 64 dots)
Dimensions 230 x 103 x 115 mm
Weight 1.3 kg
*Displayed Step / Contact voltage is obtained on base of calculation:
US = UmeasIfault / Igen; UC = UmeasIfault / Igen;
Ifault (selectable): 1 A ... 200 kA
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 10 2. 11 Accessories: page 2.31 Accessories: page 2.31
CONTINUITY TESTERS
MEASURING FUNCTIONS:
Resistance measurement with adjust-
able test current (100 mA 100 A);
Voltage drop measurement.
KEY FEATURES:
Accurate: 1 n best resolution with
0.25% accuracy.
Bar graph: on screen resistance bar
graph.
Battery powered: the instrument ena-
bles measurements with 100 A for up
to 10 minutes when powered from in-
ternal battery only.
Safe: sustain external voltages in case
of wrong connection, protection level
(CAT IV / 50 V); automatically detects
continuity in current circuit.
Single and continuous measuring
modes.
Custom limits: the limits can be set for
PASS or FAIL evaluation of test result.
Portable: rugged carrying case with
a handle and lightweight design (less
than 12 kg) enable easy moving the in-
strument between sites.
High protection degree: IP 64.
Memory: built-in memory enables
storage of up to 1000 test results.
Downloadable: downloads test re-
sults via RS232 or USB cable directly
to the PC with the help of the HVLink
PRO software.
APPLICATION:
Measurement the resistance of:
High, middle and low voltage circuit
breakers;
High, middle and low voltage discon-
necting switches;
High current busbar joints;
Cable splices;
Welding joints.
The MI 3252 MicroOhm 100A is portable low resistance ohmmeter used to measure low contact resistances of circuit
breakers, switches and busbars joints using test current from 100 mA to 100 A. Used 4-lead Kelvin testing method ensures
very high accuracy of results (0.25%) due to elimination of test leads resistance. The instrument can be powered from
both mains supply and internal battery. PC SW HVLink PRO supplied as a standard accessory enables downloading, analy-
sis and export of test results and printing of test reports.
STANDARDS:
Functionality:
IEC 62271-100;
IEC 62271-1;
ANSI C37.09;
ASTM B 539;
NMEA AB 4-1996;
El Real Decreto 223/2008
Electromagnetic compatibility:
IEC 61326-1 Class B
Safety:
EN 61010-1
MI 3252 MicroOhm 100A
CONTINUITY TESTERS
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy Current
Resistance
10.000 199.999
0.20000 1.99999 m
2.0000 ... 19.9999 m
20.000 199.999 m
0.20000 1.99999
2.0000 19.9999
1 n
10 n
100 n
1
10
100
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
100 A
100 A / 50 A
50 A / 10 A
1 / 10 A
1 A / 100 mA
100 mA
Function Resistance range Voltage range Resolution Accuracy Current
Voltage
200
2 m
20 m
200 m
2
20
1.000 mV 20.000 mV
20.00 mV 200.00 mV
10.00 mV 100.00 mV
100.0 mV 1.0000 V
20.0 mV 200.0 mV
200.0 mV 2.0000 V
20.0 mV 200.0 mV
200.0 mV 2.0000 V
20.0 mV 200.0 mV
200.0 mV 2.0000 V
1 V
10 V
10 V
0.1 mV
0.1 mV
0.1 mV
0.1 mV
0.1 mV
0.1 mV
0.1 mV
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
0.25 % of reading
100 A
100 A
50 A
50 A
10 A
1 A
10 A
1 A
100 mA
100 mA
Power supply 230 / 115 VAC
Battery 12 VDC / 12 Ah
Overvoltage category CAT IV / 50 V
Display 320 x 240 LCD with backlight
Communications RS 232 and USB
Memory 512 kB (1000 test results)
Dimensions 410 x 175 x 370 mm
Weight 11.8 kg
Instrument MicroOhm 100A
Current test lead with crocodile clip, 5 m,
25 mm
2
, 2 pcs
Potential test lead, 5 m, 2 pcs (red, black)
Test probe, 2 pcs (red, black)
Crocodile clip, 2 pcs (red, black)
Mains cable
RS232 cable
USB cable
STANDARD SET:
Bag for accessories
PC SW HVLink PRO
Instruction manual
Calibration certicate
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 12 2. 13 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Bidirectional resistance measurement
from 0,1 up to 2000 with test
current up to 10 A;
Temperature compensation (with op-
tional temperature probe).
KEY FEATURES:
Accurate: 0.1 n best resolution with
0.25% accuracy.
Bar graph: on screen resistance bar
graph.
Battery powered: more than 1000
measurements with 10 A test current
can be performed when powered by
internal battery only.
Safe: High overvoltage category CAT
IV / 300 V.
Four measuring modes: Automatic,
single, continuous and inductive
Automatic thermal EMF elimination:
with automatic bidirectional measure-
ment .
Temperature compensation: meas-
ured resistance can be adjusted ac-
cording to ambient temperature, which
can be entered manually or measured
by external probe
Custom limits: limits can be set for
PASS/FAIL evaluation of test results.
Portable: lightweight 3 kg design with
carry handle and shoulder strap.
Memory: built-in memory enables
storage of up to 1000 test results.
Downloadable: stored test results
can be via RS232 or USB interface
transferred to the PC with installed
HVLink PRO software, which enables
downloading, review, analyses and
printing of the test results.
The MI 3250 MicroOhm 2A is portable low resistance ohmmeter for measuring low resistances of breakers and switches,
busbars, cable joints, small to medium sized transformer and motor windings for industrial application, etc., with test
current up to 10 A. The used 4-lead Kelvin testing method together with automatic bidirectional procedure ensure very
high accuracy of test results (0,25%). The instrument can be powered by mains or internal rechargeable batteries. Test
results can be stored on the instrument and with PC software HVLink PRO that is supplied as a part of standard set enables
transfer of measured results to PC where they can be analyzed or printed.
MI 3250 MicroOhm 10A
APPLICATION:
Measurement the resistance of:
Bus bar joints
Motor and transformer windings
Cables
Fuses
Aircraft frame bonds
Rail and pipe bonds
Lightning conductor bonding
CONTINUITY TESTERS
STANDARDS:
Electromagnetic compatibility:
IEC 61326-1
Safety:
EN 61010-1;
EN 61010-031
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy Current
Resistance
1.9999 m
19.999 m
199.99 m
1.9999
19.999
19.999
199.99
199.99
1.9999 k
0.1
1
10
100
1 m
10 m
10 m
100 m
1
(0.25 % of reading + 0.01 % FS)
(0.25 % of reading + 0.01 % FS)
(0.25 % of reading + 0.01 % FS)
(0.25 % of reading + 0.01 % FS)
(0.25 % of reading + 0.01 % FS)
(1 % of reading + 0.1 % FS)
(0.25 % of reading + 0.01 % FS)
(1 % of reading + 0.25 % FS)
(1 % of reading + 0.25 % FS)
10 A
10 A/1 A
10 A/1 A/100 mA
1 A/100 mA/10 mA
100 mA/10 mA
1 mA
10 mA
1 mA
1 mA
Power supply (mains voltage) 90 ... 260 VAC / 60 VA
Power supply (batteries) 6 x 1.2 V NiMH 3500 mAh batteries, type C
Operation > 1000 single measurements
Overvoltage category CAT IV / 300 V
Protection class Double insulation
Display 320 x 240 LCD with backlight
Communication RS232 and USB
Memory 1000 memory locations
Dimensions 310 x 130 x 250 mm
Weight 2.8 kg
CONTINUITY TESTERS
KEY FEATURES
Test lead connection terminal with four
banana safety sockets.
Fast and simple adjustment of the test
parameters
Large analogue / digital LCD with backlight
Instrument MI 3250
Test cable, 2 m, with Kelvin Clip, 2 pcs
Test cable, 2 m, 4 pcs (2 x black, 2 x red)
Crocodile clip, 4 pcs (2 x black, 2 x red)
Test probe, 2 pcs (red, black)
Mains cable
USB cable and RS232 cable
NiMH rechargeable batteries, type C, 6 pcs
STANDARD SET:
PC SW HVLink PRO
Bag for accessories
Instruction manual
Calibration certicate
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 14 2. 15 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Bidirectional resistance measurement
from 1 up to 199,9 with test cur-
rent up to 2 A.
KEY FEATURES:
Four measuring modes: Automatic,
single, continuous and inductive
Automatic thermal EMF elimina-
tion: with automatic bidirectional
measurement.
Accurate: 1 best resolution with
0.25% accuracy.
Noise rejection: 50 Hz / 60 Hz ripple
detection and rejection.
Battery powered: more than 800
measurements of 500 m load 2
A test current & 15 s measurement
duration.
Safe: High overvoltage protection
(CAT III / 600 V) allows measurement
in substations and other points with
low line resistance. Internal protec-
tion circuit protects user and instru-
ment from inadvertent connection to
lines.
Custom limits: Pre-programmed
limits with PASS/FAIL evaluation of
measurement result and bright REEN/
RED indicators providing visual evalu-
ation of the results.
Portable: Lightweight portable de-
sign.
Memory: Up to 1500 test results with
timestamp can be stored in internal
memory.
Downloadable: PC SW HVLink PRO
enables downloading, review, analy-
ses and printing of test results.
MI 3242 MicroOhm 2A is a portable low resistance ohmmeter used to measure low resistances of switches, relays, con-
nectors, bus bars, power distribution cable joints, motor & generator winding, power transformers, power inductors, rail
track joints, wire and cable resistance, welding joints for industrial application, etc., with test current up to 2A
MI 3242 MicroOhm 2A
APPLICATION:
Measurement the resistance of:
In inductive mode:
Motor & generator winding
Power transformer
Power inductors
Wire & cable resistance
In resistance mode:
Ralays
Switches
Connectors
TECHNICAL SPECIFICATION:
KEY FEATURES
Test lead connection terminal and USB and
RS232 communication ports.
Large analogue / digital LCD with backlight Fast and simple adjustment of the test
parameters
Instrument MI 3242 MicroOhm 2A
Test cable 4 wire, 2.5 m
Crocodile clip, 4 pcs (2x black, 2x red)
Test probe, 2 pcs (black)
Power supply adapter
1.2 V NiMH rechargeable battery, 6pcs
RS232 serial cable
USB cable
STANDARD SET:
Soft carrying bag
PC SW HVLink PRO
Instruction manual
Calibration certicate
Function Measuring range Resolution Accuracy Current
Resistance
9.999 m 1
(0.25 % of reading + 2 digits)
2 A 99.99 m 10
999.9 m 100
99.99 m 10
100 mA
999.9 m 100
9.999 1 m
19.99 10 m
999.9 m 100
10 mA
9.999 1 m
99.99 10 m
199.9 100 m
Voltage
0 49.9 0.1 V
(2 % of reading + 2 digits)
50 550 1 V
Frequency
10.0 99.9 0.1 Hz
(0.2 % of reading + 1 digit)
100 500 1 Hz
Power supply (batteries) 9 VDC (6 x 1.5 V battery or accu, size AA)
Operation > 800 single measurements
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
Display 128 x 64 dots matrix display with backlight
Communication RS232 and USB
Memory 1500 memory locations
Dimensions 140 x 80 x 230 mm
Weight 0.8 kg
Busbars
Power distributor
STANDARDS:
Electromagnetic compatibility:
EN 61326 Class A
Safety:
EN 61010-1
EN 61010-031
EN 61010-2-30
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 16 2. 17 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Insulation Measurement;
Diagnostic Test (PI, DAR, DD) ;
Step Voltage Test;
Withstanding Voltage Test (DC) up to
10 kV;
Voltage and frequency measurement
up to 550 V TRMS.
KEY FEATURES:
Insulation resistance up to 20 T;
Adjustable test voltage (50 V...10 kV)
50 V and 100 V step;
Programmable timer;
Capacitance measurement;
Charging rate for capacitive load < 3 s
/ F at 10 kV;
Automatic discharge of test object af-
ter completion of measurement;
Guard terminal
High voltage breakdown detection;
Custom dened tests
Auto adjustment function
Measurement results in numerical
and graphical form;
PC software HVLink PRO for down-
loading and analyzing of the test re-
sults and test report printing;
Isolated RS232 and USB communica-
tion ports, BT interface;
High quality accessories including
shielded test leads in standard set;
High EM interferences protection:
Input AC current noise rejection (1
mA600 V) and additional averaging
of the result (5, 10, 30, 60);
CAT IV / 600 V;
Mains and rechargeable battery power
supply.
MI 3210 TeraOhm XA 10 kV is a portable, battery or mains powered test instrument with excellent IP protection (IP65),
intended for diagnosing of Insulation Resistance by using high DC test voltages of up to 10 kV. Because of its robustness
(CAT IV protection) and high immunity to radiated RF elds it is best suited for industrial environment.
APPLICATION:
Power transformers;
Measuring transducers in distribution
networks;
Testing insulation resistance of rotat-
ing machinery and cables;
Production line periodic testing and
maintenance;
Troubleshooting and analysis of all
kinds of insulation problems;
High voltage generators;
Surge arrestors.
STANDARDS:
Electromagnetic compatibility:
EN 61326 class A
Safety:
EN 61010-1 (instrument)
EN 61010-2-030
EN 61010-2-033
EN 61010-031(accessories)
MI 3210 TeraOhmXA 10 kV
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Insulation resistance
0.01 M 9.99 M
10.0 M 99.9 M
100 M 999 M
1.00 G 9.99 G
10.0 G 99.9 G
100 G 999 G
1.0 T 9.9 T
10 T 20 T
10 k
100 k
1 M
10 M
100 M
1 G
100 G
1 T
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(5% of reading + 3 digits)
(15% of reading + 3 digits)
Test voltage
0 V 999 V
1.00 kV 9.99 kV
10.0 kV 14.0 kV
1 V
10 V
100 kV
(5% of reading + 3 digits)
Insulation leakage current
1.00 mA 5.00 mA
100 A 999 A
10.0 A 99.9 A
1.00 A 9.99 A
100 nA ... 999 nA
10.0 nA .. 99.9 nA
0.00 nA 9.99 nA
10 A
1 A
100 nA
10 nA
1 nA
100 pA
10 pA
(5% of reading + 3 digits)
(10% of reading + 0.15 nA)
Dielectric absorption ratio (DAR)
0.01 9.99
10.0 100.0
0.01
0.1
(5% of reading + 2 digits)
Polarization index (PI)
0.01 9.99
10.0 100.0
0.01
0.1
(5% of reading + 2 digits)
Dielectric discharge (DD)
0.01 9.99
10.0 100.0
0.01
0.1
(5% of reading + 2 digits)
Voltage AC/DC
5.0 V 99.9 V
100 V 550 V
0.1 V
1 V
(2% of reading + 2 digits)
Frequency 10 Hz 500 Hz 0.1 Hz (0.2% of reading + 1 digits)
Capacitance
20.0 nF 999 nF
1.00 F 9.99 F
10.0 F 50.0 F
1 nF
10 nF
100 nF
(5% of reading + 2 digits)
Power supply 12 V DC (3.4 Ah Lead Acid)
Display 320 x 240 dots matrix display with backlight
Overvoltage category CAT IV / 600 V
Protection class Double insulation
COM port RS232, USB and Bluetooth
Dimensions 345 x 160 x 335 mm
Weight 6.5 kg
Instrument MI 3210 TeraOhmXA 10 kV
10 kV shielded test lead with probe, 2 m
10 kV shielded test lead, 2 m, 2 pcs (black, red)
10 kV crocodile clip, 2 pcs (black, red)
Guard test lead, green, 2 m
Crocodile clip, green
Mains cable
PC SW HVLink PRO with USB and RS 232
cable
STANDARD SET:
Handbook Guide to modern insulation
testing on CD
Instruction manual on CD
Calibration certicate
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 18 2. 19 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Insulation resistance measurement;
Step voltage insulation resistance test-
ing;
Withstanding voltage testing;
Diagnostic test (PI, DD, DAR);
R(t) graph plotting;
Capacitance measurement;
Voltage measurement;
Frequency measurement.
KEY FEATURES:
Measuring range up to 10 T.
Wide range of DC test voltages: from
500 V up to 10000 V in steps of 25 V.
Withstanding voltage: testing of in-
sulation with programmable ramp test
voltage from 500 V up to 10 kV and
programmable threshold current.
Step voltage: insulation resistance
measurement with ve discrete pro-
portionately set test voltages and pro-
grammable timer per step.
Automated testing: PI, DD, DAR cal-
culations with automated resistance
ranging. All data is displayed during
one single measurement.
Guard test terminal: for elimination of
potential surface leakage currents.
Fault finding: fully programmable step
voltage and withstanding voltage test
functions assist in diagnosing faults in
insulation.
Graph R(t): real time resistance against
time graph plotting facility to graphical-
ly illustrate the response of a material
to an applied test voltage.
Built-in timer: programmable timer
from 1 s up to 100 min.
Automatic discharge of tested object
after test.
Fast testing: 5 mA current source for
quick charging of capacitive load.
Accurate: selectable noise rejection l-
ters and shielded test leads included in
a standard set ensure accurate meas-
urement.
The new insulation tester MI 3202 TeraOhm 10 kV is a portable instrument intended to measure insulation resistance by
using high DC test voltages up to 10 kV. TeraOhm 10 kV enables insulation resistance measurements up to 10 T, step
voltage test, withstanding voltage test, PI, DD and DAR calculation and capacitance measurement. The large LCD screen
enables real-time graph R(t) to be displayed. Results can be stored and downloaded to a computer via USB or RS232 con-
nection with the help of the optional HVLink PRO software. The high quality instrument, shielded test leads and quality
accessories included in the standard set enable to perform insulation testing quickly and effectively.
Safe: high CAT IV / 600 V voltage pro-
tection.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
er and comes complete with a set of
rechargeable NiMH batteries.
Portable: lightweight 5.5 kg design
with carry handle.
APPLICATION:
Testing insulation resistance of rotat-
ing machinery, cables, transformers,
HV generators, surge arresters;
Production line periodic testing and
maintenance;
Troubleshooting and analysis of all
kinds of insulation problems;
Effective measurements in high noise
environments such as high voltage
substations and switchyards;
Diagnostic testing.
STANDARDS:
Functionality:
IEC/EN 61557-2
Electromagnetic compatibility:
EN 61326 class B
Safety:
EN 61010-1;
EN 61010-031
HIGH VOLTAGE INSULATION TESTERS
MI 3200 TeraOhm 10 kV
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Insulation resistance
5 k 999 k
1.00 M 9.99 M
10.0 M 99.9 M
100 M 999 M
1.00 G 9.99 G
10.0 G 99.9 G
100 G 999 G
1.00 T 10.00 T
1 k
10 k
100 k
1 M
10 M
100 M
1 G
10 G
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(15 % of reading + 3 digits)
Test voltage
0 V 9999 V
10 kV
1 V
0.1 kV
(3 % of reading + 3 V)
3 % of reading
Insulation leakage current
0.00 nA 9.99 nA
10.0 nA 99.9 nA
100 nA 999 nA
1.00 A 9.99 A
10.0 A 99.9 A
100 A 999 A
1.00 mA 5.50 mA
0.01 nA
0.1 nA
1 nA
10 nA
100 nA
1 A
10 A
(5% of reading + 0.05 nA)
Dielectric absorption ratio (DAR)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Polarization index (PI)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Dielectric discharge (DD)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Voltage AC/DC 0 V 600 V 1 V (3 % of reading + 4 V)
Frequency 45.0 Hz 65.0 Hz 0.1 Hz 0.2 Hz
Capacitance
0.0 nF 99.9 nF
100 nF 999 nF
1.00 F 50.00 F
0.1 nF
1 nF
10 nF
(5 % of reading + 2 digits)
Power supply 6 1.2 V NiMH rechargeable batteries, type D
Display Matrix LCD with backlight, 160 x 116 dots
Overvoltage category CAT IV / 600 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 345 x 160 x 335 mm
Weight 5.5 kg
Instrument TeraOhm 10 kV
Mains cable
10 kV shielded test lead with tip, 2 m
10 kV shielded test lead black, 2 m
10 kV shielded test lead red, 2 m
10 kV crocodile clip, 2 pcs (black, red)
Guard lead, green, 2 m
Crocodile clip, green
6 x 1.2 V NiMH rechargeable batteries, type D
STANDARD SET:
Instruction manual
Handbook on CD
Calibration certicate
HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 20 2. 21 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Insulation resistance measurement;
Step voltage insulation resistance test-
ing;
Withstanding voltage testing;
Diagnostic test (PI, DD, DAR);
R(t) graph plotting;
Capacitance measurement;
Voltage measurement;
Frequency measurement.
KEY FEATURES:
Measuring range up to 10 T.
Wide range of DC test voltages: from
250 V up to 5000 V in steps of 25 V.
Withstanding voltage: testing of in-
sulation with programmable ramp test
voltage from 250 V up to 5 kV and pro-
grammable threshold current.
Step voltage: insulation resistance
measurement with ve discrete pro-
portionately set test voltages and pro-
grammable timer per step.
Automated testing: PI, DD, DAR cal-
culations with automated resistance
ranging. All data is displayed during
one single measurement.
Guard test terminal: for elimination of
potential surface leakage currents.
Fault finding: fully programmable step
voltage and withstanding voltage test
functions assist in diagnosing faults in
insulation.
Graph R(t): real time resistance against
time graph plotting facility to graphical-
ly illustrate the response of a material
to an applied test voltage.
Built-in timer: programmable timer
from 1 s up to 10+0 min.
Automatic discharge of tested object
after test.
Fast testing: 5 mA current source for
quick charging of capacitive load.
Accurate: selectable noise rejection l-
ters and shielded test leads included in
a standard set ensure accurate meas-
urement.
The new insulation tester MI 3201 TeraOhm 5 kV Plus is a portable instrument intended to measure insulation resistance
by using high DC test voltages up to 5 kV. TeraOhm 5 kV Plus enables insulation resistance measurements up to 10 T, step
voltage test, withstanding voltage test, PI, DD and DAR calculation and capacitance measurement. The large LCD screen
enables real-time graph R(t) to be displayed. Results can be stored and downloaded to a computer via USB or RS232 con-
nection with the help of the optional HVLink PRO software. The high quality instrument, shielded test leads and quality
accessories included in the standard set enable to perform insulation testing quickly and effectively.
Safe: high CAT IV / 600 V voltage pro-
tection.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
er and comes complete with a set of
rechargeable NiMH batteries.
Portable: lightweight 3 kg design with
carry handle and shoulder strap.
APPLICATION:
Testing insulation resistance of
rotating machinery, cables, transform-
ers, HV generators, surge arresters;
Production line periodic testing and
maintenance;
Troubleshooting and analysis of all
kinds of insulation problems;
Diagnostic testing.
STANDARDS:
Functionality:
IEC/EN 61557-2
Electromagnetic compatibility:
EN 61326 class B
Safety:
EN 61010-1; EN 61010-031
MI 3201 TeraOhm 5 kV Plus
HIGH VOLTAGE INSULATION TESTERS
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Insulation resistance
5 k 999 k
1.00 M 9.99 M
10.0 M 99.9 M
100 M 999 M
1.00 G 9.99 G
10.0 G 99.9 G
100 G 999 G
1.00 T 10.00 T
1 k
10 k
100 k
1 M
10 M
100 M
1 G
10 G
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(15 % of reading + 3 digits)
Test voltage 0 V 5500 V 1 V (3 % of reading + 3 V)
Insulation leakage current
0.00 nA 9.99 nA
10.0 nA 99.9 nA
100 nA 999 nA
1.00 A 9.99 A
10.0 A 99.9 A
100 A 999 A
1.00 mA 5.50 mA
0.01 nA
0.1 nA
1 nA
10 nA
100 nA
1 A
10 A
(5 % of reading + 0.05 nA)
Dielectric absorption ratio (DAR)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Polarization index (PI)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Dielectric discharge (DD)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Voltage AC / DC 0 V 600 V 1 V (3 % of reading + 4 V)
Frequency 45.0 Hz 65.0 Hz 0.1 Hz 0.2 Hz
Capacitance
0.0 nF 99.9 nF
100 nF 999 nF
1.00 F 50.00 F
0.1 nF
1 nF
10 nF
(5 % of reading + 4 nF)
Power supply 6 1.2 V NiMH rechargeable batteries, type C
Display Matrix LCD with backlight, 160 x 116 dots
Overvoltage category CAT IV / 600 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 310 x 130 x 250 mm
Weight 3 kg
Instrument TeraOhm 5 kV Plus
Small soft carrying bag
Mains cable
10 kV shielded test lead with probe, black,
2 m
10 kV shielded test lead with probe, red,
2 m
10 kV crocodile clip, 2 pcs (black, red)
Guard lead, green, 2 m
STANDARD SET:
Crocodile clip, green
6 x 1.2 V NiMH rechargeable batteries, type C
Handbook on CD
Instruction manual
Calibration certicate
HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 22 2. 23 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Insulation resistance measurement;
Step voltage insulation resistance test-
ing;
Withstanding voltage testing;
Diagnostic test (PI, DD, DAR);
Capacitance measurement;
Voltage measurement;
Frequency measurement.
KEY FEATURES:
Measuring range up to 5 T.
Wide range of DC test voltages: from
250 V up to 5000 V in steps of 50 V.
Withstanding voltage: testing of in-
sulation with programmable ramp test
voltage from 250 V up to 5 kV and pro-
grammable threshold current.
Step voltage: insulation resistance
measurement with ve discrete pro-
portionately set test voltages and pro-
grammable timer per step.
Automated testing: PI, DD, DAR cal-
culations with automated resistance
ranging. All data is displayed during
one single measurement.
Fault finding: fully programmable step
voltage and withstanding voltage test
functions assist in diagnosing faults in
insulation.
Guard test terminal: for elimination of
potential surface leakage currents.
Automatic discharge of tested object
after test.
Accurate: selectable noise rejection l-
ters ensure accurate measurement.
Built-in timer: programmable timer
from 1 s up to 30 min.
Memory: stores up to 1000 results
with date and time stamp.
Easy to read: large custom LCD dot
matrix display with bar graph and with
backlight.
Built-in charger: instrument has a
built-in charger which enables meas-
urement during the charging.
Portable: lightweight 2.1 kg design
with carrying bag and neck strap.
The MI 2077 TeraOhm 5 kV is an advanced, eld proven high voltage diagnostic insulation tester. Its small lightweight
design make it easily portable and its bright LCD display ensures that readings can be made in almost any lighting condi-
tions. TeraOhm 5 kV enables insulation resistance measurements up to 5 T, step voltage test, withstanding voltage test,
PI, DD and DAR calculation and capacitance measurement. Built-in memory and optional PC SW TeraLink enables data
storing, downloading to PC, analysis of test results and printout of test reports.
Instrument TeraOhm 5 kV
Soft carrying bag
Mains cable
Test lead, black, 2 m
Test lead, red, 2 m
Guard lead, green, with crocodile clip, 2 m
Test probe, black
Test probe, red
Crocodile clip, black, 2 pcs
Handbook on CD
Instruction manual
Calibration certicate
STANDARD SET:
APPLICATION:
Testing insulation resistance of rotat-
ing machinery, cables, transformers,
HV generators, surge arresters;
Production line periodic testing and
maintenance;
Troubleshooting and analysis of all
kinds of insulation problems;
Diagnostic testing.
STANDARDS:
Functionality:
IEC/EN 61557-2
Electromagnetic compatibility:
EN 61326 Class B
Safety:
EN 61010-1;
EN 61010-031
MI 2077 TeraOhm 5 kV
HIGH VOLTAGE INSULATION TESTERS
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Insulation resistance
0 k 999 k
1.00 M 9.99 M
10.0 M 99.9 M
100 M 999 M
1.00 G 9.99 G
10.0 G 99.9 G
100 G 999 G
1.00 T 5.00 T
1 k
10 k
100 k
1 M
10 M
100 M
1 G
10 G
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Test voltage 0 V 5500 V 1 V (3 % of reading + 3 V)
Insulation leakage current
0.00 nA 9.99 nA
10.0 nA 99.9 nA
100 nA 999 nA
1.00 A 9.99 A
10.0 A 99.9 A
100 A 999 A
1.00 mA 1.54 mA
0.01 nA
0.1 nA
1 nA
10 nA
100 nA
1 A
10 A
(5 % of reading + 0.05 nA)
Dielectric absorption ratio (DAR)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Polarization index (PI)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Dielectric discharge (DD)
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Voltage AC / DC 0 V 600 V 1 V (3 % of reading + 3 V)
Frequency 45.0 Hz 65.0 Hz 0.1 Hz 0.2 Hz
Capacitance
0.0 nF 99.9 nF
100 nF 999 nF
1.00 F 50.00 F
0.1 nF
1 nF
10 nF
(5 % of reading + 2 digits)
Battery power supply 6 x 1.2 V NiMH rechargeable batteries, type C
Display Matrix LCD with backlight, 160 x 116 dots
Overvoltage category CAT III / 600 V
Protection class Double insulation
COM port RS232 (optional USB with serial converter)
Dimensions 265 110 185 mm
Weight 2.1 kg
KEY FEATURES
Guard connection terminal to eliminate the
inuence of surface insulation currents.
Large custom LCD dot matrix display with bar
graph and backlight.
User friendly keyboard enables simple and
fast adjustment.
HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 24 2. 25 Accessories: page 2.31 Accessories: page 2.31
MEASURING FUNCTIONS:
Insulation resistance measurement;
Voltage measurement;
Frequency measurement.
KEY FEATURES:
Measuring range up to 1 T.
Analogue scale and digital LCD:
measuring results are displayed both
in numeric and analogue form.
Quick set-up: quick and easy selection
of test voltage (250 V; 500 V; 1 kV; 2,5
kV; 5 kV).
Fast testing: 5 mA current source for
quick charging of capacitive load.
Guard test terminal: for elimination of
potintial surface leakage currents.
Automatic discharge of tested object
after test.
Safe: high CAT IV / 600 V voltage
protection.
Easy to read: large bright LCD
with backlight.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charger
and comes complete with a set of re-
chargeable NiMH batteries.
High quality accessories: shielded test
leads are included in a standard set.
Portable: lightweight 3 kg design with
carry handle and shoulder strap.
APPLICATION:
Testing insulation resistance of rotat-
ing machinery and cables;
Production line periodic testing and
maintenance;
Troubleshooting and analysis of all
kinds of insulation problems.
STANDARDS:
Functionality:
IEC/EN 61557-2
Electromagnetic compatibility:
EN 61326 class B
Safety: EN 61010-1; EN 61010-031
The MI 3202 GigaOhm 5 kV provides quick and accurate testing of insulation resistance. Five test voltages up to 5 kV and
1 T resistance measuring range cover most of the industrial and power distribution applications. The large analogue /
digital LCD screen with backlight offers easy reading of test results. The instrument is placed in a rugged carrying case
which allows to use it in harsh environments.
Instrument GigaOhm 5 kV
Mains cable
10 kV shielded test lead with probe, black, 2 m
10 kV shielded test lead with probe, red, 2 m
10 kV crocodile clip, 2 pcs (black, red)
Guard lead, green, 2 m
Crocodile clip, green
6 x 1.2 V NiMH rechargeable batteries, type C
Handbook on CD
Instruction manual
Calibration certicate
STANDARD SET:
MI 3202 GigaOhm 5 kV
HIGH VOLTAGE INSULATION TESTERS
KEY FEATURES
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Insulation resistance
5 k 999 k
1.00 M 9.99 M
10.0 M 99.9 M
100 M 999 M
1.00 G 9.99 G
10.0 G 99.9 G
100 G 999 G
1 k
10 k
100 k
1 M
10 M
100 M
1 G
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(10 % of reading + 3 digits)
Test voltage 0 V 5500 V 1 V (3 % of reading + 3 V)
Voltage AC / DC 0 V 600 V 1 V (3 % of reading + 4 V)
Frequency 45.0 Hz 65.0 Hz 0.1 Hz 0.2 Hz
Battery power supply 6 1.2 V NiMH rechargeable batteries, type C
Display Analogue / digital LCD with backlight
Overvoltage category CAT IV / 600 V
Protection class Double insulation
Dimensions 310 x 130 x 250 mm
Weight 3 kg
Guard terminal for connecting shielded test
leads
Fast and simple adjustment of the test
parameters
Large analogue / digital LCD with backlight
HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 26 2. 27 Accessories: page 2.31 Accessories: page 2.31
STANDARDS:
Functionality:
IEC/EN 61557 Parts 1,2, 4, 10
IEC/EN 60364
VDE 100
BS 7671 17th edition
CEI 64.8
Electromagnetic compatibility:
IEC/EN 61326-1;
Safety:
IEC/EN 61010-1;
EN 61010 - 031
instrument on metal surfaces enables
hands-free operation.
APPLICATION:
Measurement of insulation resistance
of transformers, motors, cables, ma-
chines, etc;
Testing on CAT IV installations (distri-
bution side of installations, industrial
plants, etc);
Observation of insulation trends;
Testing of PE conductors continuity and
main and supplementary PE connections.
MEASURING FUNCTIONS:
Insulation resistance with DC voltage
up to 2.5 kV;
Diagnostic test (PI, DAR calculation)
Continuity of PE conductors with 200
mA test current and polarity change;
Continuity of PE conductors with 7
mA test current (continuous measure-
ment) without RCD tripping;
TRMS voltage and frequency.
KEY FEATURES:
High measuring range: up to 100 G
with test voltage from 100 to 2500 V.
Insulation diagnostics: PI and DAR
calculation for determining if the insu-
lation damaged or contaminated.
Guard test terminal: for elimination of
potential surface leakage currents.
Polarity swap: automatic polarity re-
versal on continuity test.
Analogue scale: measuring results are
displayed in numeric and analogue rep-
resentation.
Custom limits: if limits are set on insu-
lation or continuity function then large
green and red lights of the LEDs will
indicate a PASS or FAIL evaluation of
test result.
Safe: suited for testing on CAT IV in-
stallations.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
ing circuit and comes complete with
a set of rechargeable NiMH batteries.
Memory: two level memory structure
for saving of test results and param-
eters.
Downloadable: downloads via RS232
or USB cable directly to the PC with
the help of the PC software EuroLink
PRO.
Easy to use: large bright LCD display
and large buttons enable easy handling
of the instrument (even while wearing
gloves).
Magnetic holder: magnet for xing
MI 3121H 2,5 kV Insulation / Continuity
The MI 3121H Smartec 2,5 kV Insulation / Continuity is the portable measuring instrument for complete diagnostic testing
of insulation and continuity measurements. Due to insulation resistance measurement with the test voltages up to 2.5 kV
(measuring range is up to 100 G) and calculation of PI and DAR indexes the instrument is suited for testing insulation of
cable lines, current and voltage transformers, electric motors, etc. Due to configurable limits the instrument enables PASS
/ FAIL evaluation of test results which is accompanied with bright green or red light of LEDs. Additional features include
magnetic holder for fixing the tester on the metal surface and built-in charger. The Mi 3121H is compatible with EuroLink
PRO software which enables downloading and analysis of test results and creation of professional test reports.
HIGH VOLTAGE INSULATION TESTERS
Large LCD screen with backlight and PASS /
FAIL indicators.
KEY FEATURES
Simple and fast manipulation.
Instrument Smartec 2,5 kV Insulation /
Continuity
Soft hand strap
Test lead, 2 x 1.5 m
Test probe, 2 pcs (black, red)
Crocodile clip, 2 pcs (black, red)
Power supply adapter + 6 NiMH recharge-
able batteries, type AA
Instruction manual on CD
Short instruction manual
Handbook on CD
Calibration certicate
STANDARD SET:
Function Measuring range Resolution Accuracy
Insulation resistance (EN 61557-2)
U = 500, 1000, 2500 VDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 999 M
1.00 G 4.99 G
5.00 G 19.99 G
20.0 G 99.9 G
U = 100, 250 VDC:
R: 0.00 M 19.99 M
20.0 M 199.9 M
200 M 999 M
0.01M
0.1M
1 M
10 M
10 M
100 M
0.01 M
0.1 M
1 M
(5 % of reading + 3 digits)
5 % of reading
5 % of reading
10 % of reading
20 % of reading
20 % of reading
(5 % of reading + 3 digits)
10 % of reading
20 % of reading
PI, DAR
0.01 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 2 digits)
5 % of reading
Continuity 200 mA of PE conductor
with polarity change (EN 61557-4)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(3 % of reading + 3 digits)
5 % of reading
10 % of reading
Low resistance measurement with 7
mA test current (continuous measure-
ment)
0.0 19.9
20 1999
0.1
1
(5 % of reading + 3 digits)
10 % of reading
Voltage
0.0 V 99.9 V
100 V 550 V
0.1 V
1 V
(3 % of reading + 3 digits)
Frequency
0.00 Hz 19.99 Hz
20.0 Hz 199.9 Hz
200 Hz 500 Hz
0.01 Hz
0.1 Hz
1 Hz
(0.2 % of reading + 1 digits)
Power supply 6 x 1.2 V rechargeable batteries, type AA
Overvoltage category CAT III / 600 V; CAT IV / 300 V
Protection class Double insulation
COM port RS232 and USB
Dimensions 140 x 230 x 80 mm
Weight 0.85 kg
TECHNICAL SPECIFICATION:
USB and RS232 communication ports.
HIGH VOLTAGE INSULATION TESTERS
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 28 2. 29 Accessories: page 2.31 Accessories: page 2.31
HVLink PRO
The HVLink PRO software works in conjunction with Metrel newest HV insulation testers, Step Contact Voltage Measuring
System and MicroOhms. The software automatically recognizes connected instrument and allows the customer to down-
load test results saved on the instrument, review the results, rename and relocate data if needed and print test reports.
KEY FEATURES:
Automatic recognition of the instru-
ment: when connecting your instru-
ment to the PC it is automatically rec-
ognized by the software.
Tree view: all the results are repre-
sented in tree view for easy data man-
agement.
Rearranging of structures: the ele-
ments of the tree structure can be re-
located and renamed.
R(t) graphs: if graph R(t) was enabled
when testing with the instrument MI
3200 or MI 3201 then it can be plotted
and printed with the software.
Measurement tables: if graph R(t)
was enabled when testing with the
instrument MI 3200 or MI 3201 then
a table with xed R(t) values can be
viewed and printed.
Export of test results: test results in
text format can be exported to other
programs (MS Excel, MS Word).
Automatic Test Report generation:
enables automatic generation of Test
Report (low, medium and high de-
tailed).
PC SW HVLink PRO is compatible with:
MI 3210 TeraOhmXA 10 kV
MI 3200 TeraOhm 10 kV
MI 3201 TeraOhm 5 kV Plus
MI 3295 Step Contact Voltage Meas-
uring System
MI 3252 MicroOhm 100A
PASSWORD PROTECTION:
PC SW HVLink PRO is password pro-
tected for the following instruments:
MI 3200
MI 3201
ORDERING INFORMATION:
A 1275 PC SW HVLink PRO with USB
and RS232-PS/2 cable
Test report
PC SOFTWARE
R(t) graph can be drawn for HV Insula-
tion Resistance measuring functions.
Table with xed R(t) values can be drawn
for HV Insulation Resistance measuring
functions.
User friendly interface with tree view
data structure and full, medium or low
representation of test results.
PC SOFTWARE
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 30 2. 31 Accessories: page 2.31 Accessories: page 2.31
The MI 3299 High voltage Demonstration Box 10 kV has been developed for demonstration purposes at high voltage
insulation diagnostics. It simulates typical electrical insulation usually met in the industrial environment. It is equipped
with high quality resistors in different ranges, high voltage capacitors and a discharge facility to simulate a breakdown
phenomenon in gases. Additionally measurements of polarization index (PI), dielectric discharge (DD) and dielectric ab-
sorption ratio (DAR) can be demonstrated. Packed with all these features the demonstration box is also well suited for
basic calibration of DC high voltage insulation resistance measuring instruments.
KEY FEATURES:
10 kV rated resistors with very low
voltage coefcient.
Resistive decade with 200 k, 500
M, 200 G and 2 T resistors.
HV capacitors in 2.5 F and 5 nF range.
Built-in spark gap and gas discharge
tube.
Demonstration of insulation break-
down in gases is possible.
Two models of insulation material (good
and bad cables) enable the demonstra-
tion of real insulation behavior under
high DC voltage.
Demonstration box is put in the strong
rugged case with handle for comfortable
carrying.
APPLICATION:
Demonstration of insulation diagnos-
tics measurement with DC test volt-
age;
Demonstration of functionality of HV
insulation measuring instruments;
Training centres, schools, laboratories;
Basic calibration of DC high voltage in-
sulation testers.
STANDARDS:
Safety:
EN 61010-1
HV demo BOX 10 kV
HV test leads, 2 pcs
Instruction manual
Handbook on CD
Calibration certicate
STANDARD SET:
TECHNICAL DATA:
Dimensions 440 320 110 mm
Weight 4 kg
MI 3299 HV demo BOX
DEMONSTRATION BOARD
Photo
Part
number
Description Target application
M
I

3
2
9
5
M
I

3
2
5
2
M
I

3
2
5
0
M
I

3
2
4
2
M
I

3
2
1
0
M
I

3
2
0
0
M
I

3
2
0
1
M
I

2
0
7
7
M
I

3
2
0
2
M
I

3
1
2
1
H
MI
3295M
Set
Step Contact Meter
Measuring Set
Additional MI 3295M Set for simultaneous measure-
ments of step voltage and contact voltage on different
test points. Set includes instrument MI 3295M, test
lead, 2 x 3 m, soft carrying bag, soft carrying neck belt,
NiMH battery, type AA, 6 pcs, Power supply adapter.

A 1014 Test probe, black
Test probe with 4 mm connection is suitable for per-
forming measurements both in mains outlets and in situ-
ations when no schuko outlet is present.

A 1013 Crocodile clip, black
Crocodile clip assures secure and permanent contact dur-
ing the measurement on bus bars, xing screws, etc.

A 1064 Crocodile clip, red
Crocodile clip assures secure and permanent contact dur-
ing the measurement on bus bars, xing screws, etc.

A 1309 Crocodile clip, green
Crocodile clip assures secure and permanent contact dur-
ing the measurement on bus bars, xing screws, etc.

S 2036
HV crocodil clip, 2 pcs
(red, black)
10 kV crocodile clips for HV insulation resistance meas-
urement assure secure and permanent contact during
the measurement on bus bars, xing screws, etc.

A 1046
1.2 V NiMH battery,
type C, 6 pcs
A set of 6 pieces of rechargeable batteries, type C.
S 2054
1.2 V NiMH battery,
type D, 6 pcs
A set of 6 pieces of rechargeable batteries, type C.
A 1169
Fast charger for AA,
C, D and 9 V block
batteries
Fast battery charger for up to 12 pcs AA, 6 pcs C or D
rechargeable batteries, 4 pcs 9 V block batteries.

A 1017
Communication cable
RS232
RS232 interface cable for connecting the instrument with
the PC.

A 1171
RS232 / USB adapter
with 1 m cable
RS232 / USB adapter for instruments without USB co-
munication port.

A 1056
PC SW TeraLink with
RS232 cable
PC Software TeraLink supplied with RS232 interface
cable supports test results downloading and creation of
test reports.

Selection Guide for HV Accessories
Option Not available
High Voltage Insulation / Continuity / Earth High Voltage Insulation / Continuity / Earth
2. 32 2. 33 Accessories: page 2.31 Accessories: page 2.31
Photo
Part
number
Description Target application
M
I

3
2
9
5
M
I

3
2
5
2
M
I

3
2
5
0
M
I

3
2
4
2
M
I

3
2
1
0
M
I

3
2
0
0
M
I

3
2
0
1
M
I

2
0
7
7
M
I

3
2
0
2
M
I

3
1
2
1
H
A 1275 PC SW HVLink PRO
HVLink PRO is a downloading and data management PC
software with R=f(t) graph printing functionality (for HV
insulation testers). It comes delivered with RS232 and
USB communication cables.

A 1291
PC SW EuroLink PRO
with USB and RS232-
PS/2 cable
PC Software EuroLink PRO enables downloading and
test results management and printing of test reports.
Delivered with RS232-PS/2 and USB communication cables.

A 1333
Resistor SHUNT,
750
Resistor SHUNT is used for testing correctness of mirco
ohmmeters.

A 1323
Current and potential
earth spike (with 3m
lead)
Auxiliary current earth spikes for decreasing the earth
resistance and potential earth spike for specic earth
measurements.

A 1353
Step voltage probe
(25 kg), 2 pcs
Additional voltage probes for step voltage measure-
ments.

S 2053 Step voltage plates Light replacement for 25kg Step voltage probes A 1353.
S 2058 Insulation test plates
Two in one: Test plates for measurement of oor and wall
insulation, 625 cm
2
(acc. to EN 60364-6) and measure-
ment of semi conductivity, 2,5 kg, 65 mm (acc. to EN
61340-5-1).

A 1012 Test lead, green, 4 m Extension test lead.
A 1154 Test lead, black, 4 m
Extension test lead for earth and continuity measure-
ments.

A 1319
2.5 kV test lead,
3 x 1.5 m
3-wire test lead with GUARD connection for insulation
resistance measurements with test voltage up to 2,5 kV.
Recommended to be used when measuring high insula-
tion resistances (>10 G).

A 1153 Test lead, black, 20 m
Extension test lead for earth and continuity measure-
ments.

A 1383
Temperature probe
with 2 m cable
Temperature probe with measuring range from -55 C to
+125 C for measurement of ambient temperature.

Selection Guide for HV Accessories
Option Not available
Selection Guide for HV Accessories
Photo
Part
number
Description Target application
M
I

3
2
9
5
M
I

3
2
5
2
M
I

3
2
5
0
M
I

3
2
4
2
M
I

3
2
1
0
M
I

3
2
0
0
M
I

3
2
0
1
M
I

2
0
7
7
M
I

3
2
0
2
M
I

3
1
2
1
H
A 1437
Test lead with Kelvin
probe
Test lead with Kelvin probe for fast resistance measure-
ments.

A 1407
Test cable Kelvin
500 A, 2,5 m
Test cable with 500 A Kelvin clamps for easy and accu-
rate resistance measurements with MI 3242.

A 1408
Test cable Kelvin,
2,5 m
Test cable with Kelvin clamps for easy resistance meas-
urements with MI 3242.

S 1072
Continuity test lead,
with crocodile clip,
2 x 2.5 m, 2 pcs
Kelvin test probes with crocodile clips and protection
shield as lightweight alternative to clips within the stand-
ard set.
-
S 2046
Current test lead with
insulated crocodile
clip, 5 m, 25 mm
2
,
2 pcs
100 A current test lead with insulated crocodile clip for per-
forming accurate resistance measurements with MI 3252.

S 2052
Current test lead with
crocodile clip, 10 m,
50 mm2, 2 pcs
Extended 100 A current test leads for accurate measure-
ments with MI 3295.

S 2003
5 kV test lead set,
2 m, 2 pcs
5 kV test lead set, including 2 test leads and 2 crocodil
clips, for safe insulation testing.

S 2029
10 kV shielded test
lead, 8 m, 2 pcs
10 kV shielded test leads improve accuracy of HV insula-
tion resistance measurement in environments with high
content of external electromagnetic interferences.

S 2030
10 kV shielded test
lead, 15 m, 2 pcs
10 kV shielded test leads improve accuracy of HV insula-
tion resistance measurement in environments with high
content of external electromagnetic interferences.

S 2039
5 kV shielded test
lead, 15 m, 2 pcs
5 kV shielded test leads for MI 2077 improve accuracy of HV
insulation resistance measurement in environments with
high content of external electromagnetic interferences.

S 2042
5 kV shielded test
lead with test probe,
10 m, 2 pcs
Set of 5 kV shielded test leads with test probe and Guard
test lead with crocodile clip for MI 2077 improves accuracy
of HV insulation resistance measurement in environments
with high content of external electromagnetic interferences.

S 2044
5 kV shielded test
lead with test probe,
15 m, 2 pcs
5 kV shielded test leads with test probe improve accuracy
of HV insulation resistance measurement in environments
with high content of external electromagnetic interferences.

Option Not available
Accessories: page 3.34
High Voltage Insulation / Continuity / Earth
2. 34 Accessories: page 2.31
GOOD TO KNOW
Testing the safety of electrical appliances 3 - 02
PAT TESTERS
Selection Guide for PAT testers 3 - 05
MI 3305 OmegaGT Plus and MI 3304 BetaGT Plus 3 - 06
MI 3310 25A SigmaGT and MI 3310 SigmaGT 3 - 08
MI 3309 BT DeltaGT 3 - 10
MI 3311 GammaGT 3 - 12
MI 2142 AlphaPAT 3 - 14
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
A 1322 and A 1422 Active 3-phase Adapter 3 - 16
DEMONSTRATION BOARD
MI 3300 Portable Appliance Simulation Board 3 - 18
GOOD TO KNOW
Testing the safety of electrical appliances, machines and switchboards 3 - 20
MACHINE AND SWITCHBOARD TESTERS
Selection Guide for Machine and Switchboard testers 3 - 23
MI 2094 CE MultiTester 3 - 24
MI 3321 MultiServicerXA 3 - 26
MI 2170 MultiServicer 3 - 28
PC SOFTWARE
PATLink PRO and PATLink PRO Plus 3 - 30
A 1433 PATLink Android NEW 3 - 32
A 1434 aPATLink Android NEW 3 - 33
Selection Guide for PAT Accessories 3 - 34
A
p
p
l
i
a
n
c
e

/

M
a
c
h
i
n
e

/

S
w
i
t
c
h
b
o
a
r
d

S
a
f
e
t
y
I
n
-
s
e
r
v
i
c
e

I
n
s
p
e
c
t
i
o
n

a
n
d

T
e
s
t
i
n
g

o
f

E
l
e
c
t
r
i
c
a
l

E
q
u
i
p
m
e
n
t
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
Appliance / Machine / Switchboard Safety
Photo
Part
number
Description Target application
M
I

3
2
9
5
M
I

3
2
5
2
M
I

3
2
5
0
M
I

3
2
4
2
M
I

3
2
1
0
M
I

3
2
0
0
M
I

3
2
0
1
M
I

2
0
7
7
M
I

3
2
0
2
M
I

3
1
2
1
H
A 1271
Small soft carrying
bag
Small soft carrying bag for transport and storage of test
instrument or accessories.

A 1006 Soft carrying bag
Large soft carrying bag for transport and storage of test
instrument and belonging accessories.

Selection Guide for HV Accessories
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 2 3. 3 Accessories: page 3.34 Accessories: page 3.34
Find out more about testing safety of
electrical equipment.
Primary goal of testing safety of elec-
trical equipment is to use all electrical
equipment without danger. Common ac-
cidents caused by electrical equipment
are:
Injuries through electric shock caused
by malfunctioned equipment;
Injuries through overheated equip-
ment;
Fire and explosions.
To prevent risk and possible danger
caused by using electrical appliances
and other equipment appropriate safety
testing procedure should be performed.
Testing of electrical equipment is not
regulated the same way in all countries.
For instance in Germany, UK, Australia
testing of all electrical equipment is
strictly regulated by law. Through their
positive experience it can be assumed
that other countries will follow in the fu-
ture.
Safety of electrical equipment depends
on different factors which can improve
or worsen the safety level.
Remaining risk
Periodic retests
Correct service and maintenance
Correct use
Independent certication
Type test
Adequate design
Consideration of safety standards
Age
Wear
Harsh
conditions
Damage
Types of safety tests of electrical equip-
ment are:
Type testing;
End of line testing;
Maintenance testing;
Periodic testing.
According to the standards electrical
equipment is divided in:
Electrical appliances;
Electrical equipment in medical use;
Electrical machines;
Electrical switchgears.
Classication of appliances by eld of
use:
Laboratory equipment;
Measuring and regulating equipment;
Testing PAT Testing PAT
GOOD TO KNOW GOOD TO KNOW
Power supplies;
Heating appliances;
Handheld tools;
Luminaries;
Consumer electronic;
Information and communication tech-
nology (computers, fax machines,
scanners, etc.);
Prolongation cords, IEC supply cords;
Appliances for medical use.
Classication of appliances by protec-
tion classes:
According to the design electrical equip-
ment can be divided in three classes. In
the table below the differences between
classes are described.
Class I II III
Marking no

III

Connection to
protection (PE)
conductor of
the installation.
yes
all accessible
metal parts
(case etc.) are
connected to
the PE connec-
tion.
no
no connection
to mains
Basic insulation performed performed
performed /
looser limits
Supplementary
or reinforced
insulation
not needed
in general,
needed if there
are acces-
sible unearthed
metal parts 1)
performed not needed
Supply cord
three pole (L,N,
PE)
can be two
pole
two pole
Notes
installation
must have ad-
equate earthing
resistance
must be
supplied from
a SELV (safety
lowvoltage)
source, typically
12 V or 24 V
Portable appliances - measurements:
Visual check
Visual test of the equipment is intended
to conrm that there are no visible signs
of damage or defects. Result of visual
test can be stored on most of Metrel
PAT testers for future reference.
Earth bond (continuity of protective
conductor) test
With the earth bond test following is de-
termined:
That the contacts between accessible
metal parts and PE conductor are rm.
That PE wire in the appliance supply
cord is undamaged.
That there are no signs of poor con-
tacts, corrosion etc.
Earth bond test
Test signal is applied between PE pin
of supply cord and accessible earthed
metal parts.
Insulation resistance
Insulation resistance between live con-
ductors and all accessible metal parts
(earthed and isolated) is checked. This
test discloses faults caused by pollution,
moisture, deterioration of insulation ma-
terial etc.
Insulation resistance test for Class I device
High DC voltage test signal is applied be-
tween connected live pins and PE con-
tact of supply cord. Unearthed accessi-
ble metal parts are NOT included in this
test and are measured as Class II items.
Insulation resistance test for Class II device
High DC voltage test signal is applied
between connected live pins and acces-
sible isolated metal part.
Substitute leakage test
In this test the live and neutral conduc-
tors of the appliance are shorted togeth-
er and voltage of 30 - 50 V AC is applied
between this point and either the earth
conductor (class I) or the probe con-
nected to any exposed conductive part
(class I and class II). The test measures
how much current passes from the live
conductors into the test point.
Substitute leakage test for Class I device
AC test signal is applied between con-
nected live pins and PE contact of supply
cord. Isolated accessible metal parts are
NOT included in this test and are meas-
ured as Class II items.
Substitute leakage test for Class II device
AC test signal is applied between con-
nected live pins and accessible isolated
metal part.
Leakage current tests
In this test the sum of leakage currents
caused by appliance insulation resist-
ances (resistive currents through the in-
sulation material, fault currents through
decreased insulation) and capacitances
(capacitive leakage current) is checked.
Excessive leakage currents are most
often caused by deterioration of the
appliance insulation (pollution, ageing,
moisture) or faults in mains circuits of
appliances.
In general three leakage currents are
measured: the differential leakage cur-
rent, the PE conductor (direct) leakage
current and the touch leakage current.
PE conductor lekage test
PE conductor leakage current test for Class I device
Appliance must be powered on. The
current owing through appliance PE
conductor is measured. Appliance must
be placed isolated against ground. Un-
earthed accessible metal parts are not
included in this test. They are consid-
ered as class II parts and are checked in
the Touch Leakage test.
Differential leakage current test
Differential leakage measures the dif-
ference in current between the live and
neutral cable which provides a true value
of how much current the appliance leaks
to ground.
Differential leakage current test for Class I device
Appliance must be powered on. The
leakage current is measured as the dif-
ference of currents through L and N
conductors. Unearthed accessible metal
parts are not included in this test. They
are considered as class II parts and are
checked in the Touch Leakage test.
Touch leakage test
Leakage leakage current is a current that
would ow via the isolated accessible
metal part (if touched) through body to
ground are measured in this test.
Touch leakage current test for Class II device
Appliance must be powered on. The
current through the isolated accessible
metal parts is measured (each part sepa-
rately).
Polarity test
Polarity test checks the correctness of
polarity of IEC leads, prolongation cords
etc is checked. With this test shorts,
crossed and opened wires in cords can
be found.
Polarity test
Measurement of load and leakage
currents with current clamps
Advantages of clamp measurements are:
Measured electrical equipment does
not need to be disconnected from the
mains.
Selective current tests can be per-
formed by embracing individual con-
ductors.
Individual currents can be measured
without disconnections.
Current clamps are best suited for:
functional testing of xed installed ap-
pliances;
functional testing of appliances with
nominal currents >16 A;
troubleshooting of current paths in ap-
pliances.
Current measurement with current clamps
Appliance must be powered on. By
embracing separate conductors load or
leakage currents can be measured.
Functional test
Functional check explores if the appli-
ance is working properly. The use of
more sophisticated measuring instru-
ments permits load testing, which is an
effective way of determination if there
are faults in the appliance.
Functional test
PRCD test
This test checks how long it takes for a
portable RCD to trip out in the case that
a fault occurs.
PRCD testing
0 %
100 %
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 4 3. 5 Accessories: page 3.34 Accessories: page 3.34
Testing PAT
GOOD TO KNOW
Part No.
MI 3305 MI 3304 MI 3310 25A MI 3310 MI 3309 MI 3311 MI 2142
OmegaGT Plus BetaGT Plus SigmaGT SigmaGT BT DeltaGT GammaGT AlphaPAT
MEASUREMENTS
Continuity 200 mA
Continuity 10 A
Continuity 25 A
Insulation resistance 250 VDC
Insulation resistance 500 VDC
Differential leakage current
Touch leakage current
Substitute leakage current
Leakage current measurements with
optional clamp

Flash test
PRCD testing
Polarity test (IEC lead test)
Functional (load) test
Voltage TRMS
ADDITIONAL FEATURES
PASS / FAIL evaluation
Mains supply check
Built-in Checkbox Option Option
Graphical LCD
Graphical on-line help
Backlight
Real time clock
QWERTY keyboard
Auto testing (organizer, custom autotests)
Barcode shortcut auto testing
Communication ports USB / RS232 / BLUETOOTH / / / / / / / / / / / / Option Option / /
Test and tag (barcode scanner + label printer)
Data download to PC
Project upload from PC
Trend (compare) on instruments LCD
Trend with PC SW PATLink PRO Plus
Number of memory locations 6500 6500 6000 6000 1500 1500 1100
STANDARD / OPTIONAL ACCESSORIES
Barcode scanner Option Option Option Option Option Option Option
Barcode label printer Option Option Option Option
QR label printer Option Option Option Option Option Option
Receipt printer Option Option Option Option Option Option
Basic PC SW Option Option
Advanced PC SW Option Option Option Option Option Option
Android APP Option Option Option
GENERAL DATA
Weight 8.4 kg 5 kg 0.86 kg 0.86 kg 3.5 kg
Dimensions 345 x 160 x 335 310 x 130 x 250 140 x 80 x 230 140 x 80 x 230 265 x 110 x 185
Selection Guide for PAT testers
PAT TESTERS
PRCD testing
Active polarity test
This test provides testing of PRCD pro-
tected cords while voltage is applied to
tested object.
Active polarity test
Autosequences
All Metrel PAT testers contain built-in
predened test sequences which are
specied sets of measurements, lim-
its and test parameters. To select the
correct test sequence rst the type
and class of appliance must be deter-
mined. Then all safety relevant acces-
sible conductive parts must be found.
After that the test sequence, test lim-
Guide through Verication on Low-voltage electrical installations : VDE 701/702
its and parameters must be selected.
It is of a great advantage if this can be
made automatically by the measuring
instrument.
Custom test sequences
In case of testing unusual appliances
or appliances that require a special
method of testing that is not included
in the standard autosequences cus-
tom dened test sequences can be
used.
Project uploading
When retesting a site or location, pro-
ject uploading allows previously saved
information to be reloaded onto the
PAT tester to speed up testing and en-
able trend comparison.
Trend comparison
Trend comparison allows test informa-
tion from different dates to be com-
pared in order to discover if deterio-
ration is occurring in an appliance. In
case the deterioration was found, the
test engineer can make an informed
decision as to if the frequency of test-
ing and inspection is sufcient for the
appliance.
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 6 3. 7 Accessories: page 3.34 Accessories: page 3.34
MI 3305 OmegaGT Plus and MI 3304 BetaGT Plus
MEASURING FUNCTIONS:
Continuity tests (200 mA,10 A, 25 A);
Insulation resistance;
Substitute leakage current;
Differential leakage current;
Touch leakage current;
IEC cord polarity test;
Leakage and load TRMS current
measurement with current clamp.
Portable RCD testing;
HV Flash test (MI 3305 only);
Functional test.
KEY FEATURES:
Autosequencing: 24 pre-set autose-
quences and custom prepared autose-
quences speed up testing and ensure
that no tests are missed.
Automated: automatic testing and
PASS / FAIL evaluation of test results
according to appropriate standard.
Project uploading: previous test data
can be uploaded for fast retesting of
the appliance.
Scan and test: optional barcoding sys-
tem and PASS / FAIL barcode label print-
ing make retesting quick and simple.
RFID: support for advanced RFID iden-
tification system.
User friendly: large LCD screen, full
QWERTY keyboard, help screens and
warnings make the instrument an ex-
tremely easy to use.
Multi-tasking: instrument performs con-
tinuity tests with different test currents,
250 V and 500 V insulation tests, differ-
ential /substitute / touch leakage mesure-
ments, functioanal and polarity tests.
Flash test: dielectic strength test after
repair safety testing (MI 3305 only).
PRCD testing: instrument enables
measurement of trip-out time of port-
able RCDs.
Clamp leakage current measure-
ment: quick measurement of leakage
current with current clamps directly
on power supply cable without discon-
nection of appliance from mains.
Trend functionality: test results can
be uploaded from PC to the instrument
for comparison between old and new
test results on-site.
Downloadable: up to 6500 test re-
sults with measuring parameters can
be stored in two level memory and
downloaded to the PC with the help of
PC SW PATLink PRO.
PC SW PATLink PRO included in the
standard set enables downloading, view-
ing, printing of test results and exporting
of data to spreadsheet applications.
PC SW PATLink PRO Plus enables ad-
vanced analysis of test results, upload
of structures and data upload to the
instrument for on site comparison of
old and new results, upload of pre-pro-
grammed custom autosequences and
creation of professional test reports.
APPLICATION:
Professional PAT testing;
General PAT testing;
Factory / warehouse PAT testing;
After repair PAT safety testing.
STANDARDS:
Functionality:
IEC 60335-1; IEC 60598-1; IEC 60745;
IEC 60745; VDE404-1; VDE404-2;
VDE 0701; VDE 0702
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1; EN 61010-031
The innovative MI 3305 OmegaGT Plus and MI 3304 BetaGT Plus are a high-class instruments intended for electrical
safety testing of a wide range of portable electrical appliances, IT equipment, IEC cords and portable RCDs according
to IEC/EN and VDE standards. This portable, self-contained and durable instruments can be moved between sites with
minimum time and effort. The large, bright LCD screen enables work with the instrument in almost all lighting condi-
tions. New features including portable RCD testing, clamp leakage current measurement, flash test (MI 3305 only),
project uploading, recall and retest functions, fixed appliance test ports, optional PASS/FAIL label printing and on-site
test result comparison make this instruments perfect for PAT testing in almost any situation.
PAT TESTERS
TECHNICAL SPECIFICATION:
STANDARD SET:
MI 3305 or MI 3304
Instrument OmegaGT Plus or BetaGT Plus
Continuity / Leakage cable
PRCD cable
Flash cable (MI 3305 only)
PC SW PATLink PRO
RS232 cable
USB cable
Crocodile clip, green
Crocodile clip, black
Test probe, green
Test probe, black
Test lead, green 1.5 m
Test lead, black 1.5 m
Instruction manual
Calibration certicate
Function Measuring range Resolution Accuracy
PE continuity (10 A, 25 A)
0.00 1.99
2.00 19.99
0.01
0.01
(5 % of reading + 3 digits)
(10 % of reading)
PE continuity (200 mA)
0.00 1.99
2.00 9.99
10.0 19.9
0.01
0.01
0.1
(5 % of reading + 3 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Insulation resistance (250 VDC, 500 VDC)
0.000 M 0.500 M
0.501 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
0.001 M
0.001 M
0.01 M
0.1 M
(10 % of reading + 5 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Substitute leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Touch leakage current 0.00 mA 1.99 mA 0.01 mA (10 % of reading + 5 digits)
Differential leakage current 0.00 mA 9.99 mA 0.01 mA (5 % of reading + 5 digits)
Functional test: apparent power 0.00 kVA 4.00 kVA 0.01 kVA (5 % of reading + 3 digits)
Current with clamp-on adapter
0.00 mA 9.99 mA
10.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 24.9 A
0.01 mA
0.1 mA
1 mA
0.01 A
0.1 A
(5 % of reading + 5 digits)
Flash insulation test (MI 3305 only) 0.00 mA 2.50 mA 0.01 mA (5 % of reading + 5 digits)
Portable RCD: trip-out time
(IN= 10 mA, 15 mA, 30 mA)
0 ms 1999 ms (xIN)
0 ms 300 ms (IN)
0 ms 40 ms (5xIN)
1 ms
1 ms
1 ms
3 ms
Polarity test Test voltage < 50 VAC
Power supply 115 V / 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
Protection class I
COM port RS232 and USB
Dimensions 345 x 160 x 335 mm
Weight 8.4 kg
Fast and easy access to test procedure:
select the auto test and press START.
Input / output ports:
Barcode reader
Printer
PC
KEY FEATURES
PAT TESTERS
MI 3305
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 8 3. 9 Accessories: page 3.34 Accessories: page 3.34
MI 3310 25A SigmaGT and MI 3310 SigmaGT
PAT TESTERS
MEASURING FUNCTIONS:
Earth bond resistance with 10 A, 25 A
(MI 3310 25A);
Continuity test with 200 mA;
Insulation resistance;
Insulation resistance of isolated ac-
cessible conductive parts;
Substitute leakage current;
Substitute leakage current of isolated
accessible conductive parts;
Differential leakage current;
Touch leakage current;
IEC cord polarity test;
Leakage and load currents with cur-
rent clamp;
RCD and portable RCD testing;
Functional test.
KEY FEATURES:
Autosequencing: pre-programmable
VDE compatible autosequences, up to
50 custom prepared autosequences
and barcode autotests speed up testing
and ensure that no tests are missed.
Active polarity: innovative solution for
testing of RCD protected cords while
voltage is applied to the tested item.
Dual powered: instrument can be
powered from both internal battery
and mains supply (115 V and 230 V).
Fixed appliance testing: additional in-
puts and optional accessories enable
testing of xed installed appliances.
Scan and test: optional barcoding sys-
tem and PASS / FAIL barcode label print-
ing make retesting quick and simple.
RFID: support for advanced RFID iden-
tication system.
Project uploading: previous test data can
be uploaded for fast retesting of the object.
Trend functionality: test results can
be uploaded from PC to the instrument
for comparison between old and new
test results on site.
Memory: up to 6000 test results with
parameters can be stored into memory
and downloaded to the PC with the
help of PC SW PATLink PRO.
User friendly: large LCD screen, full
QWERTY keyboard, help screens and
warnings make handling the instru-
ment very simple and clear.
Clamp leakage current measurement:
quick measurement of leakage current
with current clamps directly on power
supply cable without disconnection of
appliance from mains.
RCD testing: instrument enables test-
ing of parameters of RCDs and port-
able RCDs.
Bluetooth: enables communication
with PC, printers, and Android devices.
Android application: enables ad-
vanced data management, use of
smart phones camera for scanning QR
and bar-code.
PC SW PATLink PRO included in the
standard set enables downloading,
viewing, printing of test results and
exporting of data to spreadsheet ap-
plications.
PC SW PATLink PRO Plus enables ad-
vanced analysis of test results, upload
of structures and data upload to the
instrument for on site comparison of
old and new results, upload of pre-pro-
grammed custom autosequences and
creation of professional test reports.
APPLICATION:
Professional PAT safety testing;
General PAT safety testing;
Multi-location PAT safety testing.
STANDARDS:
Functionality:
VDE 0404-1; VDE 0404-2; VDE 0701-
0702; AS / NZS 3760; NEN 3140
Electromagnetic compatibility:
EN 61326-1
Safety:
EN 61010-1; EN 61010-031; EN 61010-2-032
The MI 3310 / MI 3310 25A SigmaGT is a multifunctional portable test instrument intended to perform all measure-
ments for complete testing the electrical safety of portable electrical equipment. Along with numerous features like
dual power supply support, built-in battery charger, lightweight design, large bright LCD, soft Qwerty keypad, internal
memory for up to 6000 results and Bluetooth technology, the instrument offers innovative solution for RCD protected
cords testing and enables testing of fixed appliances. Powerful data management PC software PATLink PRO enables
upload and download of test results and parameters for further data handling, trend analysis and test report creation.
PAT TESTERS
TECHNICAL SPECIFICATION:
STANDARD SET:
MI 3310
Instrument MI 3310 SigmaGT
Small soft carrying bag
Test lead, black, 1.5 m
Crocodile clip, black
Test probe, black
IEC test cable, 2 m
Mains cable 16 A
NiMH rechargeable batteries, type C, 6 pcs
PC software PATLink PRO
RS232 cable
USB cable
Instruction manual on CD
Short instruction manual
Calibration certicate
Function Measuring range Resolution Accuracy
Earth bond resistance, 10 A, 25 A
(MI 3310 25A only)
0.00 1.99
2.00 19.99
0.01
0.01
(5 % of reading + 3 digits)
10 % of reading
PE continuity, 200 mA
0.00 1.99
2.00 9.99
10.0 19.9
0.01
0.01
0.1
(5 % of reading + 3 digits)
10 % of reading
10 % of reading
Insulation resistance (250 VDC, 500 VDC)
0.000 M 0.500 M
0.501 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
0.001 M
0.001 M
0.01 M
0.1 M
(10 % of reading + 5 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Substitute leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Touch leakage current 0.00 mA 3.99 mA 0.01 mA (10 % of reading + 5 digits)
Differential leakage current 0.00 mA 9.99 mA 0.01 mA (5 % of reading + 5 digits)
Functional test: apparent power 0.00 kVA 4.00 kVA 0.01 kVA (5 % of reading + 3 digits)
Current with current clamp
0.00 mA 9.99 mA
10.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 24.9 A
0.01 mA
0.1 mA
1 mA
0.01 A
0.1 A
(5 % of reading + 10 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Portable RCD: trip-out time
(IN= 10 mA, 15 mA, 30 mA)
0 ms 300 ms (xIN)
0 ms 300 ms (IN)
0 ms 40 ms (5xIN)
1 ms
1 ms
1 ms
3 ms
RCD: trip-out time
(IN= 10 mA, 15 mA, 30 mA)
0 ms 300 ms (xIN)
0 ms 300 ms (IN)
0 ms 40 ms (5xIN)
0.1 ms
0.1 ms
0.1 ms
3 ms
3 ms
1 ms
Polarity test Test voltage < 50 VAC
Power supply 6 x 1.2 V NiMH rechargeable batteries, type C; 115 V / 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
COM port RS232, USB and Bluetooth (MI 3310A only)
Dimensions 310 x 130 x 250 mm
Weight 5 kg
STANDARD SET:
MI 3310 25A
Instrument MI 3310 25A SigmaGT
Small soft carrying bag
Test lead, 1.5 m, 3 pcs (brown, green,
black)
Crocodile clip, 3 pcs (brown, green, black)
Test probe, 3 pcs (brown, green, black)
IEC test cable, 2 m
Mains cable 16 A
NiMH rechargeable batteries, type C, 6 pcs
PC software PATLink PRO
RS232 cable
USB cable
Instruction manual on CD
Short instruction manual
Calibration certicate
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 10 3. 11 Accessories: page 3.34 Accessories: page 3.34
MI 3309 BT DeltaGT
MEASURING FUNCTIONS:
Functional and visual inspection;
Earth bond resistance;
Insulation resistance;
Insulation resistance of isolated ac-
cessible conductive parts;
Substitute leakage current;
Substitute leakage current of isolated
accessible conductive parts;
Differential leakage current test;
Touch leakage test;
RCD and portable RCD testing;
Power test;
IEC cord polarity test;
Leakage and load currents with cur-
rent clamp;
TRMS voltage meter.
KEY FEATURES:
Autosequencing: pre-programmable
VDE compatible autosequences, up to
50 custom prepared autosequences
and barcode autotests speed up testing
and ensure that no tests are missed.
Dual powered: the instrument can op-
erate from mains power or batteries.
PASS / FAIL: large green and red lights
for additional PASS / FAIL indication
placed at the sides of the LCD.
Fixed appliance testing: additional in-
puts and optional accessories enable
testing of xed installed appliances.
Scan and test: optional barcoding sys-
tem and PASS / FAIL barcode label print-
ing make retesting quick and simple.
RFID: support for advanced RFID iden-
tication system.
RCD testing: instrument enables test-
ing of parameters of RCDs and port-
able RCDs.
Memory: large data ash memory al-
lows to store up to 1500 test results
and parameters for further download-
ing to PC.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
ing circuit and comes complete with a
set of rechargeable NiMH batteries.
Bluetooth: enables communication
with PC, printers, and Android devices.
Android application: enables ad-
vanced data management, use of
smart phones camera for scanning QR
and bar-code.
PC SW PATLink PRO included in the
standard set enables downloading, view-
ing, printing of test results and exporting
of data to spreadsheet applications.
PC SW PATLink PRO Plus enables ad-
vanced analysis of test results, upload of
pre-programmed custom autosequences
and creation of professional test reports.
APPLICATION:
Professional PAT safety testing;
General PAT safety testing;
After repair PAT safety testing.
STANDARDS:
Functionality:
EN 61557; VDE 0404-1; VDE 0404-2;
VDE 0701-0702; NEN 3140
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1; EN 61010-031
The new MI 3309 BT DeltaGT is both battery and mains powered multifunctional instrument intended to perform meas-
urements for testing the electrical safety of portable electrical equipment. Integrated unique PRCD testing technology
prevents tripping out of mains RCD during measurement. Due to dual power capability of MI 3309 it enables perform-
ing of differential leakage current test in spite of its lightweight portable design. Large graphical LCD with backlight,
two PASS / FAIL LED indicators and HELP screens for each measurement make the handling of the instrument clear
and simple. Up to 1500 test results with parameters can be stored in the internal memory of the instrument and then
downloaded to the PC for further data handling and creation of test report. Lightweight design, pre-programmed and
custom test sequences, optional barcoding, android keyboard application and RFID systems make the MI 3309 an ideal
instrument for high volume professional safety testing of portable appliances.
PAT TESTERS
TECHNICAL SPECIFICATION:
STANDARD SET:
MI 3309
Instrument MI 3309 BT DeltaGT
Small soft carrying bag
IEC cable, 2 m, 2 pcs
Test lead, black, green, brown, 1.5 m
Crocodile clip, black, green, brown
Test probe,black, green, brown
PC software PATLink PRO
RS232 cable
USB cable
NiMH rechargeable batteries, type AA,
6 pcs
Instruction manual on CD
Short instruction manual
Calibration certicate
Inputs for testing xed appliances. Large LCD screen with backlight and PASS /
FAIL indicators.
KEY FEATURES
Function Measuring range Resolution Accuracy
PE continuity (200 mA)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(5 % of reading + 3 digits)
Indication only
Indication only
Insulation resistance (250 VDC, 500 VDC)
0.00 M 19.99 M
20.0 M 49.9 M
50.0 M 199.9 M
0.01 M
0.1 M
0.1 M
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Indication only
Substitute leakage current (30 VAC)
0.00 mA 9.99 mA
10.0 mA 20.0 mA
0.01 mA
0.1 mA
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Touch leakage current 0.00 mA 7.00 mA 0.01 mA (10 % of reading + 5 digits)
Differential leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Functional test: apparent power 0.00 kVA 4.00 kVA 0.01 kVA (5 % of reading + 3 digits)
RCD and portable RCD: trip-out time
(IN= 10 mA, 15 mA, 30 mA)
0 ms 300 ms (xIN)
0 ms 300 ms (IN)
0 ms 40 ms (5xIN)
0.1 ms
0.1 ms
0.1 ms
3 ms
3 ms
1 ms
Clamp current
0.00 mA 9.99 mA
10.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 16.0 A
0.01 mA
0.1 mA
1 mA
0.01 A
0.1 A
(5 % of reading + 10 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Voltage TRMS 80 V ... 300 V 1 V (2 % of reading + 2 digits)
Polarity test Test voltage < 50 VAC
Power supply 6 x 1.2 V NiMH rechargeable batteries, type AA; 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
COM port RS232, USB and Bluetooth
Dimensions 140 x 80 x 230 mm
Weight 1.2 kg
PAT TESTERS
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 12 3. 13 Accessories: page 3.34 Accessories: page 3.34
MEASURING FUNCTIONS:
Continuity test with 200 mA;
Insulation resistance;
Insulation resistance of isolated ac-
cessible conductive parts;
Substitute leakage current;
Substitute leakage current of isolated
accessible conductive parts;
IEC cord polarity test;
TRMS voltage;
Functional and visual inspection.
KEY FEATURES:
Autosequencing: pre-programmable
VDE compatible autosequences, up
to 50 custom prepared autosequenc-
es and barcode autotests speed up
testing and ensure that no tests are
missed.
Checkbox: built-in calibration unit per-
forms calibration of the instrument and
the calibration results are automatically
stored into instruments memory.
PASS / FAIL: large green and red lights
of the LEDs indicate a PASS or FAIL
evaluation of test result.
Scan and test: optional barcoding sys-
tem and PASS / FAIL barcode label print-
ing make retesting quick and simple.
RFID: support for advanced RFID iden-
tication system.
User friendly: large LCD screen, two
Pass / Fail LED indicators, help screens
and warnings make the instrument an
extremely easy to use.
Multi-tasking: instrument performs
continuity test, 250 V and 500 V insula-
tion tests, substitute leakage measure-
ment, functioanal and polarity tests.
Memory: up to 1500 test results with
measuring parameters can be stored
in two level memory and download-
ed to the PC with the help of PC SW
PATLink PRO.
Built-in charger & rechargeable bat-
teries: instrument has a built-in charg-
ing circuit and comes complete with a
set of rechargeable NiMH batteries.
Android application: enables ad-
vanced data management, use of
smart phones camera for scanning QR
and bar-code.
PC SW PATLink PRO enables down-
loading, viewing, printing of test re-
sults and exporting of data to spread-
sheet applications.
PC SW PATLink PRO Plus enables ad-
vanced analysis of test results, upload of
pre-programmed custom autosequenc-
es, creation of professional test reports.
APPLICATION:
Professional PAT testing;
General PAT testing;
After repair PAT safety testing.
STANDARDS:
Functionality:
EN 61557; VDE 0404-1; VDE 0404-2;
VDE 0701; VDE 0702; NEN 3140
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1; EN 61010-031
The new MI 3311 GammaGT is a battery powered multifunctional instrument intended to perform measurements for
testing the electrical safety of portable electrical equipment. Due to large graphical LCD with backlight, two PASS / FAIL
LED indicators and HELP screens for each measurement the handling of the instrument is clear and simple. Up to 1500
test results with parameters can be stored in the internal memory of the instrument and then downloaded to the PC
for further data handling and creation of test report. Lightweight design, pre-programmed and custom test sequences,
optional barcoding, android keyboard application and RFID systems and built-in calibration unit make the MI 3311 an
ideal instrument for high volume professional safety testing of portable appliances.
MI 3311 GammaGT
PAT TESTERS
TECHNICAL SPECIFICATION:
STANDARD SET:
MI 3311
Instrument GammaGT
Small soft carrying bag
IEC cable, 2 m
Test probe, black
Test lead, black, 1.5 m
Crocodile clip, black
Power supply adapter
NiMH rechargeable batteries, type AA,
6 pcs
Instruction manual
Calibration certicate
PAT TESTERS
KEY FEATURES
Function Measuring range Resolution Accuracy
PE continuity (200 mA)
0.00 19.99
20.0 199.9
200 1999
0.01
0.1
1
(5 % of reading + 3 digits)
Indication only
Indication only
Insulation resistance (250 VDC, 500 VDC)
0.00 M 19.99 M
20.0 M ... 49.9 M
50.0 M ... 199.9 M
0.01 M
0.1 M
0.1 M
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Indication only
Substitute leakage current
0.00 mA 9.99 mA
10.0 mA 20.0 mA
0.01 mA
0.1 mA
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Voltage 0 V 300 V 1 V (2 % of reading + 2 digits)
Polarity test Test voltage < 50 VAC
Power supply 6 x 1.2 V NiMH rechargeable batteries, type AA
Overvoltage category CAT II / 300 V
COM port RS232, USB and Bluetooth (optional A 1436 BT dongle)
Dimensions 140 x 80 x 230 mm
Weight 0.86 kg
Large LCD screen with backlight and PASS /
FAIL indicators.
Simple and fast manipulation. USB and PS/2 connectors for communication
with PC and barcode scanner.
READY
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 14 3. 15 Accessories: page 3.34 Accessories: page 3.34
MI 2142 AlphaPAT
MEASURING FUNCTIONS:
Continuity tests (200 mA, 10 A, 25 A);
Insulation resistance;
Substitute leakage current;
Differential leakage current;
Touch leakage current;
IEC cord polarity test;
Leakage and load TRMS current
measurement with current clamp;
Functional test.
KEY FEATURES:
Autosequencing: built in Autose-
quences speed up testing and ensure
no tests are missed.
Automated: automatic testing and
Pass/Fail evaluation of results accord-
ing to the code of practice.
Adaptable: tests both 230 V appli-
ances and 115 V appliances (via socket
adapter included in standard set).
Multi-tasking: can perform Hard and
Soft Earth Bond test, 250 V / 500 V in-
sulation tests, differential /substitute
/ touch leakage test, Load tests, fuse
tests and polarity tests.
Intelligent: hard or soft tests are cho-
sen automatically to reduce the risk of
damage occurring on the selected ap-
pliance.
Downloadable: with memory capac-
ity of 1100 locations, the unit can be
downloaded to a computer via the
PATLink software (included in the
standard set).
APPLICATION:
Domestic PAT testing;
Hotel PAT testing;
General PAT testing;
Factory / warehouse PAT testing.
STANDARDS:
Functionality:
VDE 0701;
VDE 0702;
BS 89;
IEC 60335-1;
IEC 60598-1;
IEC 60745;
IEC 60950
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1
AlphaPAT is a handheld instrument intended for safety testing of electrical portable appliances, information technology
equipment and IEC cords. Autosequence mode offers 110 pre-programmed autotests based on appliance type and class,
length of supply cord, maximum current capacity etc. and allows to program up to 50 custom test sequences for speed-up
appliances safety testing. Internal memory of the instrument allows to store up to 1100 results and then download them
to the PC for storage and report creation with the help of the PC SW PATLink PRO included in the standard set. The simple
menu system, bright LCD screen, optional barcoding system, automated PASS / FAIL evaluation of test results and built-in
help screens make this instrument an extremely easy to use.
STANDARD SET:
MI 2142
Instrument AlphaPAT
Carrying bag
Continuity / Leakage cable
PC software PATLink PRO
Instruction manual
Calibration certicate
PAT TESTERS
Mobile phone type keypad for fast entering
of appliance data and date.
Input / output ports: barcode reader,
RFID reader / writer, printer, PC.
KEY FEATURES
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
PE continuity (25 A, 10 A, 200 mA) 0.00 19.99 0.01 (5 % of reading + 3 digits)
Insulation resistance (250 VDC, 500
VDC)
0.000 M 0.500 M
0.501 M 1.999 M
2.00 M 19.99 M
0.001 M
0.001 M
0.01 M
(10 % of reading + 5 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Substitute leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Differential leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Touch leakage current 0.00 mA 1.99 mA 0.01 mA (5 % of reading + 5 digits)
Functional test 0.00 kVA 3.70 kVA 0.01 kVA (10 % of reading + 3 digits)
Current with clamp-on adapter
0.00 mA 9.99 mA
10.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 24.9 A
0.01 mA
0.1 mA
1 mA
0.01 A
0.1 A
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Power supply 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
Protection class I
COM port RS232
Dimensions 265 x 110 x 185 mm
Weight 3.5 kg
Small and lightweight design makes AlphaPAT
ideal for PAT testing on variety of environments.
PAT TESTERS
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 16 3. 17 Accessories: page 3.34 Accessories: page 3.34
A 1322 and A 1422 Active 3-phase Adapter
KEY FEATURES:
Testing of Open-Circuit Voltage at ARC
Welding Units in accordance to EN
60974-4 (1422 only).
All tests on 3-phase electrical equip-
ment can be carried out, including live
leakage test, power, polarity, RCD and
Active polarity.
Simple connection to the PAT/MA-
CHINE tester with automatic detection.
Simple test procedures, identical to
single phase equipment.
Test sequence for 3-phase tests are
automatically set, based on entered
test codes and input voltages.
Built-in CEE 3-PH/32A 5 pin, CEE
3-PH/16A 5 pin and CEE 1-PH/16A 3
pin test sockets.
Instrument comes complete with all
accessories necessary for comfortable
measurements and kept in a robust
waterproof case.
APPLICATION:
Testing of single and 3-phase ARC
Welding equipment (1422 only);
Professional 3-PH portable appliance
testing;
Professional 3-PH machine testing.
STANDARDS:
Functionality:
EN 60974-4; VDE 0544-4; VDE 0404-1;
VDE 0404-2; VDE 0701-0702; EN 60204-
1 Ed.5; EN 60439; EN 61439-1; AS / NZS
3760; NEN 3140
Electromagnetic compatibility:
EN 61326-1
Safety:
EN 61010-1; EN 61010-031
Metrels all new A 1322 Multifunctional test adapter is designed for troubleshooting, as well as for periodic testing on
3-phase appliances and machinery. Unique functions such as, active polarity testing, differential leakage testing and test-
ing of 3-phase RCDs make the A 1322 Active 3-phase Adapter an ideal instrument for advanced applications. The A 1322
adapter is designed for use alongside the MI 3321 MultiservicerXA and the MI 3310/MI 3310 25A SigmaGT enabling func-
tional tests to be carried out on machines up to 40 A. Several test socket outlets make this instrument an ideal tester for
testing industrial extension leads that may also be RCD protected.
The A 1422 Multifunctional test adapter has complete support for testing of Arc Welding Equipment in accordance to EN
60974-4 and VDE 0544-4.
Due to the powerful test data management included with both supporting test instruments, all test data can easily be
equipped with needed parameters. This data can be stored into the large memory included, and with the support of the
powerful data management system PC SW Patlink Pro, exported as professional test reports.
STANDARD SET:
A 1322
Active 3-Phase Adapter
Bag for accessories
Connection cable betwen Adapter and
Instrument
3-phase mains cable 16 A male / 32 A
female, 5 pin, 2 m
RS232 cable
Instruction manual, short instruction
manual
Calibration certicat
A 1422
Test lead, 1.5 m, (blue, red)
Test probe, (blue, red)
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
Function Measuring range Resolution Accuracy
Differential leakage current
(230/400 VAC or 120/208 VAC)
0.00 mA 9.99 mA 0.01 mA (5 % of reading + 5 digits)
Power / Functional test
(230/400 VAC or 120/208 VAC)
0.00 kVA 24.29 kVA 0.01 kVA (5 % of reading + 5 digits)
Active power readout 0.00 kW 24.29 kW 0.01 kW (5 % of reading + 5 digits)
Reactive power readout 0.00 kVAr 24.29 kVAr 0.01 kVAr (5 % of reading + 5 digits)
Power factor readout 0.00 1.00 0.01 (5 % of reading + 5 digits)
3-phase RCD / Test current
(10 mA, 15 mA, 30 mA, 100 mA,
300 mA)
0 ms 300 ms ( x IN, IN )
0 ms 150 ms (2 x IN)
0 ms 40 ms (5 x IN)
1 ms
1 ms
1 ms
3 ms
3 ms
3 ms
Portable RCD trip-out current
readout (B type PRCD)
0.2 x IN 2.2 x IN 0.05 x IN 0.1 x IN
Power supply 230 V 10 %
Overvoltage category CAT II / 300 V
Protection class I
COM port RS232
Dimensions 335 x 160 x 335 mm
Weight 7.2 kg
A 1422 (only)
Welding circuit leakage current;
Primary leakage current readout
0.00 mA 14.99 mA 0.01 mA (5 % of reading + 5 digits)
No load voltage readout;
(AC peak or DC peak)
(AC RMS)
0.0 A 199.9 mA
0.0 A 139.9 mA
0.1 A
0.1 A
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
TECHNICAL SPECIFICATION:
KEY FEATURES
A 1422
A 1322 and A 1422 MI 3310 MI 3310 25A MI 3321
Earth bond / continuity resistance 200 mA
Earth bond / continuity resistance 10A / 25 A / / /
Continuity (single / auto)
Insulation resistance
Insulation resistance s
High voltage test
Loop impedance and prospective fault current
Discharging time
Voltage, frequency, three-phase rotary eld
Substitute leakage current
Substitute leakage s
Differential leakage current
3-phase differential leakage current
Touch leakage current
Polarity test
Active polarity test
3-phase polarity test / 3-phase active polarity test
Clamp current test
P/RCD test
3-phase P/RCD test
Power / functional test
3-phase power / functional test
A 1422 (only)
Continuity test (according to IEC/ EN 60974-4)
Insulation resistance (according to IEC/ EN 60974-4)
Leakage current (according to IEC/ EN 60974-4)
No load voltage (according to IEC/ EN 60974-4)
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 18 3. 19 Accessories: page 3.34 Accessories: page 3.34
MI 3300 Portable Appliance Simulation Board
KEY FEATURES:
Practically unlimited number of differ-
ent equipment (portable appliances,
machines and switchgears) can be
simulated by using different tables
(eight are included in a standard set).
On demand the demonstration board
can be simply upgraded with new ta-
bles.
Normal and fault situations can be
switched on and off, offering fault con-
ditions for the assessment of learning.
Demoboard simulates the following
faults: PE continuity faults, insulation
resistance faults, leakage and touch
leakage faults, polarity and functional
faults.
The demonstration board is built into a
strong rugged case with a handle and
detachable lid for storing leads, adapt-
ers and manuals.
APPLICATION:
Presentation of complete safety test-
ing of any portable appliance, machine
or switchgear;
Demonstration of PAT test equipment
operation by sales personnel.
STANDARDS:
Safety:
EN 61010-1
The MI 3300 PAT Demoboard is an excellent instrument for teaching or demonstrating PAT testing. The MI 3300 simulates
a wide variety of portable equipment in normal operation or in fault conditions with the simple flick of a switch. The
strong rugged portable case with detachable lid allows the unit to be easily moved between sites. The ability of the unit
to simulate unlimited number of different equipment and the possibility to set fault conditions make the PAT Demoboard
the ideal unit for teaching or assessing learning in classrooms, training sessions, demonstration sessions, seminars and
on PAT training courses.
DEMONSTRATION BOARD
KEY FEATURES TECHNICAL SPECIFICATION:
STANDARD SET:
Protection class I
Nominal input voltage 230 V
Optional on request 115 V
Power consumption 15 VA max.
Overvoltage category CAT II / 300 V
Frequency range 45 Hz 66 Hz
Pollution degree 2
Dimensions 345 x 160 x 335 mm
Weight 2.76 kg
8 demonstration tables (iron, receiver, IEC
cord, extension drum, coffee machine,
washing machine, switchgear)
Normal and fault conditions can be switched
on and off.
MI 3300
Instrument PAT Demoboard
8 demonstration tables (iron, receiver, IEC
cord ,extension drum, coffee machine,
washing machine, switchgear)
Jumper
IEC cord
Mains cable
Class I mains cable
Class II mains cable
Test cable for discharge time testing
Carrying bag for demonstration tables
Handbook Electrical Equipment Testing
on CD
Instruction manual
Calibration certicate
DEMONSTRATION BOARD
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 20 3. 21 Accessories: page 3.34 Accessories: page 3.34
Testing the safety of machines and switchboards
GOOD TO KNOW
Find out more about testing safety of
machines.
Typical hazardous situations related to
electrical equipment are:
failures or faults in the electrical equip-
ment resulting in the possibility of
electric shock or electrical re;
failures or faults in control circuits re-
sulting in the malfunctioning of the
machine;
disturbances or disruptions in power
sources as well as failures or faults in
the power circuits resulting in the mal-
functioning of the machine;
loss of continuity of circuits that de-
pends on sliding or rolling contacts,
resulting in failure of a safety function;
electrical disturbances either from out-
side the electrical equipment or inter-
nally generated, resulting in the mal-
functioning of the machine;
release of stored energy (either electri-
cal or mechanical) resulting in electric
shock or unexpected movement that
can cause injury;
audible noise at levels that cause
health problems to persons;
surface temperatures that can cause
injury.
To verify the electrical safety of ma-
chines the appropriate measurements
should be performed:
after erection of machine;
after installation of machine;
after upgrading or changing of ma-
chine;
and during periodic retests of machine.
Verication of safety of machines
According to IEC/EN 60204, Ed.5 veri-
cation of electrical safety of machines is
performed by inspection and measure-
ments:
Inspection that the electrical equip-
ment complies with its technical docu-
mentation;
Verication of protection against indi-
rect contact by automatic disconnec-
tion;
Insulation resistance test;
High voltage test;
Protection against residual voltages;
Functional tests.
Safety - measurements:
Visual test
A visual check must be carried out be-
fore each electrical safety test.
The visual inspection discloses most of
faults!
A thorough visual check must be carried
out before each electrical safety test.
Check of:
Wiring connection points. Especially
PE connections are important !
Protection covers, housings
Inscriptions and markings related to
safety must be clearly readable.
Cable layout, radiuses, isolation
Switches, regulators,lamps, keys
Parts subjected to wear out
Electrical and mechanical protection
devices (barriers, switches, fuses,
alarms)
Openings, lters
Technical documentation, instructions
for use available
Installation of the appliance must be
performed according to the user man-
uals.
During visual inspection the measuring
points for the electrical testing have to
be determined too.
Check that there are no signs of:
Damage
Pollution, moisture, dirt that can jeop-
ardize safety
Corrosion
Overheating
Verication of protection against indirect
contact by automatic disconnection
This verication step is quite complex
and must always be carryed out in some
form. The standard EC/EN 60204, Ed.5
allows simplied testing procedures re-
garding to the status of machine.
The status of the machine can be select-
ed on base of:
Condition of supplied machine (dis-
mantled, fully assembled);
Technical documentation (availability
of existing verication report of electri-
cal wiring of machine);
Length of conductors after installation;
Incoming supply characteristics - loop
impedance.
How to select the appropriate machine
status and test extent is described in
EN/IEC 60204, Table 9.
Once the machine status and test extent
are dened the limits for the Continuity
and/or ZLOOP test should be dened.
Continuity test
This test determines that the PE and
equipotential connections inside the ma-
chine have proper resistance that corre-
sponds to their length and cross-section.
Size of test current should be between
at least 0.2 A and approximately 10 A
Higher currents are preferred ,especial-
ly for low resistance values, i.e. larger
cross sectional areas and/or lower con-
ductor length.
Before continuity measurement test
leads compensation is required to elimi-
nate the inuence of test leads resist-
ance and instruments internal resist-
ance.
Continuity test
Testing the safety of machines and switchboards
GOOD TO KNOW
Insulation resistance test
This test discloses faults caused by pol-
lution, moisture, deterioration of insula-
tion metal, etc.
Insulation resistance between live con-
ductors and accessible (earthed or iso-
lated) metal parts is checked.
Insulation resistance test
Components and devices that are not
rated to withstand the test voltage shall
be disconnected during the testing.
Lower test voltages should be used
for sensitive electronic equipment and
surge protective devices.
High voltage withstanding test
The HV withstanding test is used to con-
rm integrity of the insulation materials.
During the test the insulation materi-
als in the machine are stressed with a
higher voltage than during normal opera-
tion. A powerful AC high voltage source
is applied between the live/ neutral input
terminals and the metal housing of the
machine. The instrument trips out if the
leakage current exceeds the predened
limit.
HV withstanding test
Components and devices that are not
rated to withstand the test voltage shall
be disconnected during the testing.
Components and devices that have
been voltage tested in accordance with
their product standards may be discon-
nected during testing.
Loop impedance and prospective fault
current
The instrument measures the imped-
ance of the fault loop and calculates the
prospective fault current. The results
can be compared to limit values set on
base of selected protective circuit break-
ers or RCDs. The measurement com-
plies with requirements of the standard
EN 61557-3.
Loop impedance test
RCD testing
Various test and measurements are re-
quired for verication of RCDs in RCD
protected machines. Measurements are
complies to the EN 61557-6 standard.
The following measurements and tests
can be performed:
Contact voltage,
Trip-out time,
Trip-out current,
RCD autotest.
Testing of RCD in RCD protected machine
Testing of RCD in electrical installation
Discharge Time
If large capacitors in machines are dis-
connected from supply there is often a
remaining (residual) charge on internal
machine components.
Live parts having a residual voltage
greater than 60 V after the supply has
been disconnected, shall be discharged
to 60 V or less within a time period of 5 s
after disconnection of the supply.
For plugs or similar devices with ex-
posed conductors (for example pins) if
plugged out it shall be discharged to 60
V or less within a time period of 1 s after
disconnection of the supply.
Discharge time test
Functional test
Functional check explores if the ma-
chine is working properly.
Following items should be checked
while the machine is operating:
Temperature regulators, monitors;
RCDs and other disconnection devic-
es;
Operation of functional disconnecting
devices;
Operation of switches, lamps, keys;
Rotating parts, motors, pumps;
Power consumption, etc.
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 22 3. 23 Accessories: page 3.34 Accessories: page 3.34
CE MultiTester integrated into the automated production line.
Testing the safety of machines and switchboards Selection Guide for appliances, machines and switchboards testers
Part No.:
MI 2094 MI 3321 MI 2170
CE MultiTester MultiServicerXA MultiServicer
MEASUREMENTS
Withstanding test 1000 VAC
Withstanding test 1890 VAC
Withstanding test 2500 VAC
Withstanding test 100 ... 5000 VAC (500 VA)
Continuity 100 mA
Continuity 200 mA
Continuity 10 A
Continuity 25 A
Voltage drop test 10 A
Insulation resistance 250 VDC
Insulation resistance 500 VDC
Insulation resistance 1000 VDC
Differential leakage current
Touch leakage current
Substitute leakage current
Discharge time
Leakage current measurement with optional clamp
RCD, PRCD testing
Line impedance
Loop impedance
Voltage measurement
Frequency measurement
Phase rotation indication
Polarity test (IEC lead test)
Functional (load) test
ADITIONAL FEATURES
PASS / FAIL evaluation
Mains supply autocheck
Graphical LCD
Graphical on-line help
Backlight
Real time clock
QWERTY keyboard
Auto testing (organizer, custom autotests)
Barcode shortcut auto testing
Communication ports RS232 / USB / / / Option
Test and tag (barcode scanner + label printer)
Data download to PC
Project upload from PC to instrument
Trend (compare) on instruments LCD
Trend with PC SW PATLink PRO Plus
Number of memory locations 1638 6000 62
STANDARD / OPTIONAL ACCESSORIES
Barcode scanner Option Option
Label printer Option
Receipt printer Option
PC SW PATLink PRO (download, report, data export)
PC SWPATLink PRO Plus (download, PRO Plus report, data export, trend) Option Option
PC SW CE Link (download, report, autosequence editor) Option
GENERAL DATA
Power supply 115 V / 230 V 115 V / 230 V 230 V
Weight 13.5 kg 8.4 kg 9.5 kg
Dimensions (mm) 410 x 175 x 370 345 x 160 x 335 345 x 160 x 335
MACHINE AND SWITCHBOARD TESTERS
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 24 3. 25 Accessories: page 3.34 Accessories: page 3.34
MI 2094 CE MultiTester
MEASURING FUNCTIONS:
Withstanding programmed voltage;
Withstanding voltage test;
High voltage burn-out test;
Continuity tests;
Insulation resistance measurement;
Substitute leakage current;
Differential leakage current;
Touch leakage current;
Discharge time;
Functional test (power, voltage, cur-
rent, cos , frequency).
KEY FEATURES:
Auto testing: up to 10 autosequences
each composed of up to 50 steps, in-
cluding pauses and comments, can be
created via the optional CE Link soft-
ware and saved in the memory of the
instrument.
Withstanding voltage test: testing
of insulation with programmable test
voltage up to 5 kV.
Burn test: instrument performs in-
sulation breakdown test with limited
breakdown current.
Continuity testing: wide selection of test
currents (100 mA, 200 mA, 10 A, 25 A).
Easy to use: rotary switch makes the
selection of a single test simple and
easy while the programmable autose-
quence testing prevent the risk of
missing a test.
Portable: due to lightweight design
and rugged carrying case with handle
CE MultiTester can be moved between
locations.
Safe: high quality accessories and op-
tional safety devices like remote con-
trol pedal and warning lamp ensure the
most safe performance of the meas-
urements.
Rack mount: due to the autotest facil-
ity and EXT / DOOR remote control of
the instrument CE MultiTester can be
integrated into the automated produc-
tion line for output check of manufac-
tured products.
Multi-system testing: the instrument
can be used on TT, TN, IT and 115 V
supply systems.
Downloadable: the optional PC SW CE
Link enables the upload of test sequenc-
es, downloading of test results directly
to the PC, automatic data storage into a
le and printing of test reports.
APPLICATION:
Portable appliances, switchgears, ma-
chines safety testing;
Testing and verifying of manufactured
products according to European Safety
legislation;
The MI 2094 CE MultiTester is intended for electrical safety testing and CE certication of electrical appliances, machines
and switchboards during the production. It is suitable for testing the appliances after repairs and maintenance work as
well. With the ability to test a multitude of different appliances the MI 2094 still remains portable, safe and easy to use.
The optional PC software CE Link enables the upload of automated test sequences, downloading of test results directly
to the PC, automatic data storage into a le and printing of test reports. Due to selected test functions, durable construc-
tion and accompanying PC SW package CE MultiTester is the perfect instrument for electrical safety testing in the most
demanding environments like laboratories, automated production lines or specialized workshops.
Testing of electrical appliances after re-
pairs and maintenance work.
STANDARDS:
Functionality:
EN 61557; EN 60204-1; EN 60335-1;
EN 60439-1; EN 60598-1; IEC 60745;
IEC 60755; EN 61010-1; IEC 60950;
IEC 61029; IEC 61558-1; EN 60065;
VDE 701 T1; VDE 702 T1
Safety: IEC 61010-1
Electromagnetic compatibility:
EN 61326
MACHINE AND SWITCHBOARD TESTERS
TECHNICAL SPECIFICATION:
STANDARD SET:
Function Measuring range Resolution Accuracy
Withstanding test (PROG.HV and HV)
- Test voltage (AC)
0.100 kV 0.999 kV
1.000 kV 5.000 kV
0.001 kV
0.001 kV
(2 % of reading + 5 digits)
(3 % of reading + 5 digits)
- Test current 0.0 mA 500.0 mA 0.1 mA (5 % of reading + 5 digits)
PE continuity
- Test current 10 A and 25 A
0.000 0.999
1.000 2.000
2.001 9.999
0.001
0.001
0.001
(3 % of reading + 3 digits)
(3 % of reading + 10 digits)
Indicator only
- Test current 100 mA
0.00 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 12 digits)
(5 % of reading + 6 digits)
- Test current 200 mA
0.00 9.99
10.0 100.0
0.01
0.1
(5 % of reading + 6 digits)
(5 % of reading + 6 digits)
Insulation resistance
0.000 M 1.999 M
2.000 M 199.9 M
200 M 999 M
0.001 M
0.001 M, 0.01 M, 0.1 M
1 M
(5 % of reading + 10 digits)
(3 % of reading + 3 digits)
(10 % of reading + 10 digits)
Differential leakage current
0.00 mA 3.99 mA
4.0 mA 20.0 mA
0.01 mA
0.1 mA
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Substitute leakage current 0.00 mA 20.00 mA 0.01 mA (5 % of reading + 3 digits)
Touch leakage current 0.00 mA 2.00 mA 0.01 mA (5 % of reading + 3 digits)
Functional test
- Active and apparent power (W or VA)
0.0 199.9
200 3500
0.1
1
(5 % of reading + 10 digits)
(5 % of reading + 3 digits)
- Voltage 0 V 400 V 1 V (2 % of reading + 2 digits)
- Test current
0.000 A 0.999 A
1.00 A 15.99 A
0.001 A
0.01 A
(3 % of reading + 5 digits)
(5 % of reading + 5 digits)
- cos 0.00 1.00 0.01 (3 % of reading + 3 digits)
- Frequency 45.00 Hz 65.00 Hz 0.01 Hz (0.1 % of reading + 3 digits)
Discharge time 0 s 10 s 0.1 s (2 % of reading + 0.2 s)
Power supply 115 V / 230 V, 50 Hz / 60 Hz
Overvoltage category CAT III / 300 V; CAT II / 600 V
Protection class I
COM port RS232 and USB
Dimensions 410 x 175 370 mm
Weight 13.5 kg

MI 2094
Instrument CE MultiTester
HV test pistol with 2 m cable, 2 pcs
Continuity test lead, 2.5 m, 2 pcs
Insulation test lead, red, 2.5 m
Insulation test lead, black, 2.5 m
Crocodile clip, black, 3 pcs
Crocodile clip, red, 2 pcs
Discharge time cable
Mains cable
Bag for accesories
Instruction manual
Calibration certicate
MACHINE AND SWITCHBOARD TESTERS
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 26 3. 27 Accessories: page 3.34 Accessories: page 3.34
MI 3321 MultiServicerXA
MEASURING FUNCTIONS:
Continuity tests (200 mA, 10 A);
Insulation resistance;
Withstanding voltage tests (1000 V,
1890 V, 2500 V);
Substitute leakage current;
Differential leakage current;
Touch leakage current;
IEC cord polarity test;
Leakage and load TRMS current meas-
urement with current clamp;
Portable RCD testing;
RCD testing;
Line and loop impedance;
High resolution line / loop impedance (m).
Discharge time;
Three phase voltage / rotary eld;
Functional test.
KEY FEATURES:
3 in 1: instrument performs testing of
portable appliances (acc. to VDE 0701
0702), machines (acc. to IEC/EN 60204
Ed.5) and switchgears (acc. to IEC/ EN
60439 and the new IEC 61439) including
functional and leakage tests for DUTs
with nominal power up to 3.5 kW.
Multi-tasking: up to 18 different meas-
urements can be performed either as
a single test or pre-programmed test
sequences (PAT mode).
Automated: automatic testing and
PASS / FAIL evaluation of test results
according to appropriate standard.
Project uploading: previous test data
can be uploaded for fast retesting of
the object.
Scan and test: optional barcoding sys-
tem and PASS / FAIL barcode label print-
ing make retesting quick and simple.
RFID: support for advanced RFID iden-
tification system.
User friendly: large LCD screen, full
QWERTY keyboard, help screens and
warnings make the instrument an ex-
tremely easy to use.
Fixed appliance tests: ports, leads and
optional accessories fully support the
testing of fixed machines and applianc-
es while normal socket supports plug-
in machines and appliances testing.
RCD testing: instrument enables test-
ing of parameters of RCDs and port-
able RCDs.
Clamp leakage current measurement:
quick measurement of leakage current
with current clamps directly on power
supply cable without disconnection of
appliance from mains.
Discharge time test: testing of how
long it takes for the machine discharge
after power is removed.
Withstanding voltage test: instru-
ment performs 2500 VAC, 1890 VAC and
1000 VAC withstanding voltage tests
with settable current limit.
Trend functionality: test results can
be uploaded from PC to the instrument
for comparison between old and new
test results on site.
Downloadable: up to 6000 test re-
sults with measuring parameters can
be stored in two level memory and
downloaded to the PC with the help of
PC SW PATLink PRO.
PC SW PATLink PRO included in the
standard set enables downloading, view-
ing, printing of test results and exporting
of data to spreadsheet applications.
PC SW PATLink PRO Plus enables ad-
Multifunctional portable test instrument MI 3321 MultiServicerXA is intended to perform all necessary measurements for
testing the electrical safety of portable electrical equipment, machines and switchgears. It is the rst machine tester cover-
ing all necessary tests according to new IEC/EN 60204 ed.5 including Loop impedance, RCD and HV tests. MultiServicerXA
enables measurement of discharge time, power and current consumption and resistance to excessive voltages which are
the main parameters in the safety testing of hard wired appliances and large machinery. With an easy to use user interface,
large graphic LCD, QWERTY keyboard, help menus with connection diagrams and extra ports for testing xed installations
the MI 3321 is the best solution for safety testing.
vanced analysis of test results, upload
of structures and data upload to the
instrument for on site comparison of
old and new results, upload of pre-pro-
grammed custom autosequences and
creation of professional test reports.
APPLICATION:
Factory machinery safety testing;
Industrial safety testing;
Portable appliances safety testing;
Switchgear safety testing.
STANDARDS:
Functionality: IEC/EN 61557; IEC 60439-1;
EN 60204; IEC/EN 60204-1 Ed.5;
IEC/EN 60439; IEC 60755; IEC 60598-1;
VDE 0404; VDE 0701-0702
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1; EN 61010-031
MACHINE AND SWITCHBOARD TESTERS
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Withstanding test with 1890 VAC and 2500 VAC:
- Test voltage 0 V 3000 V 1 V (5 % of reading + 5 digits)
- Current 0.0 mA 99.9 mA 0.1 mA (10 % of reading + 8 digits)
Withstanding test with 1000 VAC:
- Test voltage 0 V 1500 V 1 V (5 % of reading + 5 digits)
- Current
0.0 mA 199.9 mA
200 mA 500 mA
0.1 mA
1 mA
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Insulation resistance with 250 VDC; 500 VDC
0.000 M 0.500 M
0.501 M 1.999 M
2.00 M 19.99 M
20.0 M 199.9 M
0.001 M
0.001 M
0.01 M
0.1 M
(10 % of reading + 5 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
Insulation - S resistance with 250 VDC; 500 VDC
0.000 M 0.500 M
0.501 M 1.999 M
2.00 M 19.99 M
0.001 M
0.001 M
0.01 M
(10 % of reading + 5 digits)
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
PE continuity with 10 A (PAT) 0.00 1.99 0.01 (5 % of reading + 3 digits)
PE continuity with 10 A (other)
0.000 0.999
1.00 1.99
0.001
0.01
(5 % of reading + 6 digits)
(5 % of reading + 3 digits)
PE continuity with 200 mA 0.00 1.99 0.01 (5 % of reading + 3 digits)
Discharge time 0.0 s 9.9 s 0.1 s (5 % of reading + 3 digits)
Differential leakage current 0.00 mA 9.99 mA 0.01 mA (5 % of reading + 5 digits)
Substitute leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Touch leakage current 0.00 mA 2.50 mA 0.01 mA (10 % of reading + 5 digits)
Functional test 0.00 kVA 4.00 kVA 0.01 kVA (5 % of reading + 3 digits)
TRMS current with clamp
0.00 mA 9.99 mA
10.0 mA 99.9 mA
100 mA 999 mA
1.00 A 9.99 A
10.0 A 24.9 A
0.01 mA
0.1 mA
1 mA
0.01 A
0.1 A
(5 % of reading + 10 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
PRCD testing IN: 10, 15, 30 mA
- Trip-out time
0 ms 300 ms (1/2xIN)
0 ms 300 ms (IN)
0 ms 40 ms (5xIN)
1 ms
1 ms
1 ms
3 ms
3 ms
3 ms
RCD testing IN: 10, 30, 100, 300, 500, 1000 mA
- Contact voltage
0.0 V 19.9 V
20.0 V 99.9 V
0.1 V
0.1 V
(-0 %/+15 %) of reading 10 dig.
(-0 %/+15 %) of reading
- Trip-out time
0.0 ms 40.0 ms
0.0 ms 300.0 ms
0.1 ms
0.1 ms
1 ms
3 ms
- Trip-out current
0.2IN 1.1IN (AC type)
0.2IN 1.5IN (A type, IN 30 mA)
0.2IN 2.2IN (A type, IN <30 mA)
0.05IN
0.05IN
0.05IN
0.1IN
0.1IN
0.1IN
Fault loop impedance / Line impedance
0.00 9.99
10.0 99.9
100 1999
0.01
0.1
1
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
10 % of reading
Voltage 0 V 550 V 1 V (2 % of reading + 2 digits)
Frequency 14.0 Hz 499.9 Hz 0.1 Hz (0.2 % of reading + 1 digit)
Power supply 115 V / 230 V, 50 Hz / 60 Hz
Overvoltage category CAT II / 300 V
Protection class I
COM port RS232 and USB
Dimensions 345 x 160 x 335 mm
Weight 8.4 kg
STANDARD SET:
MI 3321
Instrument MultiServicerXA
HV test lead
Plug test cable
3-wire test lead
Test lead, black, 1.5 m
Test lead, red, 1.5 m
Test lead, red, 4 m
Test lead, green, 1.5 m
Test probe, 4 pcs (black, red. green, blue)
Crocodile clip, black, 3 pcs
Protective bag for accessories
PC SW PATLink PRO with RS232 and USB
cable
Instruction manual
Calibration certicate
MACHINE AND SWITCHBOARD TESTERS
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 28 3. 29 Accessories: page 3.34 Accessories: page 3.34
MEASURING FUNCTIONS:
Insulation resistance;
Withstanding voltage tests (1000 V,
2500 V);
Continuity tests (200 mA, 10 A);
Voltage drop;
Substitute leakage current;
Differential leakage current;
Touch leakage current;
Discharge time;
Functional test.
KEY FEATURES:
3 in 1: instrument performs testing
of portable appliances, machines and
switchgears including functional and
leakage tests for DUTs with nominal
power up to 3.5 kW.
Easy to use: instrument connection
guide on lid and rotating function se-
lector make the MI 2170 an extremely
easy to use.
PASS / FAIL: configurable limits enable
evaluation of test results according to
appropriate standard.
Fixed appliance tests: ports, leads
and optional accessories fully support
the testing of fixed machines and ap-
pliances while normal socket supports
plug-in machines and appliances test-
ing.
Discharge time test: testing of how
long it takes for the machine discharge
after power is removed.
Withstanding voltage test: instru-
ment performs 2500 VAC and 1000 VAC
withstanding voltage tests with setta-
ble current limit.
Downloadable: test results can be
stored in two level memory structure.
PC SW PATLink PRO included in the
standard set enables downloading,
viewing, printing of test results and
exporting of data to spreadsheet ap-
plications.
PC SW PATLink PRO Plus enables
advanced analysis of test results and
creation of professional test reports.
APPLICATION:
Factory machinery safety testing;
Industrial safety testing;
Portable appliances safety testing;
Switchgear safety testing.
The MI 2170 MultiServicer is a multifunctional portable test instrument intended for performing all necessary measure-
ments for testing the electrical safety of machines, switchgears and portable electrical appliances. Apart from insulation
resistance, leakage currents and continuity measurements, MultiServicer enables measurement of discharge time, current
consumption and resistance to excessive voltages which are the main parameters in the safety testing of hard wired ap-
pliances and large machinery. MultiServicer is placed into robust waterproof case for use in harsh industrial environments.
Quick reference guide for testing, large LCD screen, user friendly interface and rotary function selector make the safety
testing with MultiServicer quick and simple.
STANDARDS:
Functionality:
IEC 60204; IEC 60439-1; VDE 701;
VDE 702; IEC 60598-1; IEC 60755;
IEC 50144-1
Electromagnetic compatibility:
EN 50081-1;
EN 61000-6-1
Safety:
EN 61010-1
MI 2170 MultiServicer
MACHINE AND SWITCHBOARD TESTERS
STANDARD SET:
MI 2170
Instrument MultiServicer
HV test lead
Test lead, black, 2 m
Test lead, red, 2 m
Test probe, black
Test probe, red
Crocodile clip, black
Crocodile clip, red
PC SW PATLink PRO with RS232 cable
Protective bag for accessories
Instruction manual
Calibration certicate
Function Measuring range Resolution Accuracy
Withstanding test with 2500 VAC:
- Test voltage 0.00 kV 3.00 kV 0.01 kV (5 % of reading + 5 digits)
- Current 0.0 mA 99.9 mA 0.1 mA (5 % of reading + 5 digits)
Withstanding test with 1000 VAC:
- Test voltage 0.00 kV 1.50 kV 0.01 kV (5 % of reading + 5 digits)
- Current
0.0 mA 109.9 mA
110 mA 500 mA
0.1 mA
1 mA
(5 % of reading + 5 digits)
(5 % of reading + 5 digits)
Insulation resistance measurement with 500 VDC 0.00 M 19.99 M 0.01 M (5 % of reading + 5 digits)
Voltage drop 0.00 V 11.99 V 0.01 V (5 % of reading + 5 digits)
PE continuity with 200 mA 0.00 19.99 0.01 (5 % of reading + 5 digits)
PE continuity with 10 A 0.000 1.999 0.001 (5 % of reading + 5 digits)
PE continuity with 200 mA 0.00 19.99 0.01 (5 % of reading + 5 digits)
Discharge time 0.0 s 9.9 s 0.1 s (5 % of reading + 3 digits)
Differential leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Substitute leakage current 0.00 mA 19.99 mA 0.01 mA (5 % of reading + 5 digits)
Touch leakage current 0.00 mA 1.99 mA 0.01 mA (5 % of reading + 5 digits)
Functional test; current 0.00 A 15.99 A 0.01 A (5 % of reading + 3 digits)
Power supply 230 V, 50 Hz
Overvoltage category CAT III / 300 V
Protection class I
COM port RS232
Dimensions 345 x 160 x 335 mm
Weight 9.5 kg
MACHINE AND SWITCHBOARD TESTERS
TECHNICAL SPECIFICATION:
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 30 3. 31 Accessories: page 3.34 Accessories: page 3.34
PATLink PRO and PATLink PRO Plus
PC software PATLink PRO is an advanced, user friendly software package designed with the portable appliance testing
engineer in mind. The graphical interface with drag and drop data relocation, data ltering, data archiving functions and
automatic report generation allows a variety of users with a range of different skills and abilities to create professional
reports which include company logos. The PATLink PRO Plus software introduces extra features including the ability to
reload data onto Metrel uploadable / downloadable testers, perform trend analysis on equipment and introduces PRO
Plus certicates and individual appliance reports.
KEY FEATURES:
Full data ltering: All data can be l-
tered by different parameters: Retest
Date, Test Date, Project, User, etc.
Tree style or table style: Data can be
represented in tree or table view.
Drag and drop: The elements of the
structure can be relocated and renamed.
Customer database: It allows test engi-
neer to create his own database of cus-
tomers fully equipped with all appropri-
ate data.
Company logo loading: Load company
logos into the software so that they can
be printed on test reports.
Data backup: All downloaded data can
be backed up to prevent the loss of valu-
able data for example in case of hard
disk failure.
Appliance information editing: Allows
you to edit data, e.g. to set up Retest
Date, Repair Code, add Comments, etc.
Export of test results: Data of selected
appliances together with test results can
be exported to other programs (MS Excel,
MS Word).
PDF report: Test Report can be trans-
formed into PDF format.
Full built-in help les: Integrated help
menu contains detailed explanation of
PC SW handling.
Automatic self-test record keeping: Re-
sults of the CHECKBOX function (MI 3311
only) can be automatically transferred to
the PC and printed onto the test reports.
Plug & Play: When meter is connect-
ed to the PC it is automatically recog-
nized by the software.
Upload data back to PAT tester: User
can upload test results from the previ-
ous measurement session (e.g. from last
year) so the same tests can be simply
repeated and results of both measure-
ments can be compared (MI 3321, MI
3305, MI 3304, MI 3310 25A, MI 3310).
Autosequences upload: Test autose-
quences can be prepared via PATLink
PRO and then sent to the tester (MI
3321, MI 3305, MI 3304, MI 3310 25A,
MI 3310, MI 3309, MI 3311) for testing
speedup.
Structures upload: The structure of test
site can be created in advance on the PC
and then simply uploaded to the tester
(MI 3321, MI 3305, MI 3304, MI 3310
25A, MI 3310); if needed any deviations
can be adjusted on the tester on site.
Trend analysis: Enables to compare test
results of the last and previous tests.
Automatic PRO report generation:
Enables automatic generation of Test
Report (standard or full detailed).
PATLink PRO Plus professional reports:
The PRO Plus report displays results as
the PRO version but enables editing the
information before printing the report.
PC SW PATLink PRO / PRO Plus is com-
patible with:
MI 3321 MultiservicerXA
MI 2170 Multiservicer
MI 3305 OmegaPAT Plus
MI 3304 BetaPAT Plus
MI 3310 / MI 3310 25A SigmaGT
MI 3309 BT Delta GT
MI 3311 GammaGT
The following Certicates for PRO
version are available:
Full detailed PRO Electrical equip-
ment test report;
METREL PAT PRO Electrical equip-
ment test report.
The following Certicates for PRO
Plus version are available:
METREL PRO Plus (Single) Electrical
equipment test report;
METREL Full detailed PRO Electrical
equipment test report;
METREL PAT PRO Plus Electrical
equipment test report.
PASSWORD PROTECTION:
PC SW PATLink PRO is password pro-
tected for the following instrument:
MI 3311
PC SW PATLink PRO Plus is password
protected for all Metrel PAT testers.
ORDERING INFORMATION:
A 1305 PC SW PATLink PRO with USB
and RS232-PS/2 cable
A 1306 PC SW PATLink PRO Plus with
USB and RS232-PS/2 cable
A 1203 Upgrade code PATLink PRO to
PATLink PRO Plus
PC SOFTWARE
Custom autotest sequence can be cre-
ated on PC and then uploaded to the
instrument
Trend analysis (comparison of results
from tests performed in different time
period)
Full detailed PRO Plus Report Full detailed PRO Report
PC SOFTWARE
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 32 3. 33 Accessories: page 3.34 Accessories: page 3.34
A 1433 PATLink Android
The PATLink Android is a powerful tool. It enables fast and simple data management of tested appliances, as well as a
quick overview of already performed tests by simply scanning a QR code. The Application enables the user to enter and
save data to the test instrument by using a Smart phones keyboard. Also it enables a creation of the custom made data-
base for portable appliances IDs, the appliancess names and the appliances locations. All these features enable the user
a faster and easier data handling.
PATLink Android enables the user to
scan the QR codes which contain in-
formation of the previous results, the
test status, and the previously used
test sequence. Based on this informa-
tion the user can start the retest of the
appliance with a single press on the
Android Application.
KEY FEATURES:
On - site comparrison of the test re-
sults;
Creation of the custom database;
Use of Smart phones camera for the
QR and Barcode scanning;
Use of Smart Phones virtual keyboard.
ADDITIONAL FEATURES:
In Built Risk Assessment tool to pro-
vide correct Re-Test periods in accord-
ance with COP version 4;
Protect your business by applying QR
codes instead of Bar Codes.
PATLink Android is compatible with:
MI 3309 BT DeltaPAT
MI 3310 25A SigmaPAT (HW3)
MI 3311 GammaPAT
(supported by BT dongle) READY
Supported by
BT dongle
Built-in BT
solution
PC SOFTWARE
A 1434 aPATLink Android
The aPATLink Android is Advanced Portable Appliance Testing tool. It enables fast and simple data management of tested
appliances, as well as a quick overview of already performed tests by simply scanning a QR code. The Application enables
the user to send results to the main ofce before leaving test site, enter and save data to the test instrument by using a
Smart phones keyboard. Also it enables a creation of the custom made database for portable appliances IDs, the appli-
ancess names and the appliances locations. All these features enable the user a faster and easier data handling.
KEY FEATURES:
Complete database of tested applianc-
es on one location;
Upcoming retest warning on your
smart phone or tablet;
Simple, custom auto-test creation (MI
3309 DeltaPAT);
Use of smart phones barcode or QR
code scanner for quicker data entry;
Remote control of PAT tester;
Easy data entering;
Projects can be stored to your drop
box account;
Sending data to main ofce, before
leaving test site;
Built in risk assessment calculator;
None skilled user can perform test
simply by scanning the QR code con-
taining all needed information for spe-
cic appliance;
Overview of testing parameters by
simple scanning QR code.
ADDITIONAL FEATURES:
In Built Risk Assessment tool to pro-
vide correct Re-Test periods in accord-
ance with COP version 4;
Protect your business by applying QR
codes instead of Bar Codes.
aPATLink Android is compatible with:
MI 3309 BT DeltaPAT
MI 3310 25A SigmaPAT (HW3)
MI 3311 GammaPAT
(supported by BT dongle)
READY
Supported by
BT dongle
Built-in BT
solution
PC SOFTWARE
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 34 3. 35 Accessories: page 3.34 Accessories: page 3.34
Selection Guide for PAT Accessories
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1143 Euro Z 290 A
Euro Z 290 A is the impedance tester which
enables line / loop impedance measurements
with an accuracy down to 0.1 m.

A 1322 Active 3-phas Adapter
A 1322 Multifunctional test adapter is designed
for troubleshooting, as well as for periodic test-
ing on 3-phase appliances and machinery.

A 1422
Active 3-phas Adapter
Plus
A 1422 Multifunctional test adapter is designed
for troubleshooting, as well as for periodic test-
ing on 3-phase appliances, machinery, and ARC
welding equipment.

A 1207 Three phase adapter
The 3-phase adapter for substitute leakage cur-
rent, insulation resistance and continuity meas-
urements on electric loads equipped with 16A
and 32A CEE 3P sockets.

A 1316
3-phase adapter
(16 A CEE-Schuko)
3-phase adapter for testing 3-phase appliancess.
A 1317
3-phase adapter
(32 A CEE-Schuko)
3-phase adapter for testing 3-phase appliancess.
A 1110 Three phase adapter
3-phase test adapter for installation safety test-
ing on 3-phase sockets type 16 A 3CEE.

A 1111
A 1215
(for
MI 2150)
Three phase adapter
with switch
3-phase adapter with selection switch for instal-
lation safety testing on 3-phase sockets type 16
A 3CEE. The adapter allows seamless switching
between measurements.

A 1373
3-phase mains cable
/ adapter 32 A male
/ 32 A female, 5 pin,
2 m
3-phase test adapter, for testing of 3 phase ex-
tension leads in combination with A 1322 / Active
3-phase Adapter.
3-phase power supply cable for A 1322 / Active
3-phase adapter.

A 1375
1-phase mains cable
/ adapter 32 A / 16 A
Schuko, 3 pin, 2 m
1-phase Power supply cable for A 1322 / Active
3-phase adapter.

A 1376
3-phase adapter 16 A
male / 16 A female, 5
pin, 2 m
3-phase test adapter, for testing of 3 phase ex-
tension leads in combination with A 1322 / Active
3-phase Adapter.

A 1394
1-phase adapter 16 A
male / 16 A female, 3
pin, 2 m
1-phase test adapter for, testing of 1 phase exten-
sion leads in combination with A 1322 / Active
3-phase Adapter.

Option Not available
Selection Guide for PAT Accessories
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1418
1-phase adapter 16 A,
3 pin female / 16 A
Schuko male, 2 m
1-phase test adapter for, testing of 1 phase exten-
sion leads in combination with A 1322 / Active
3-phase Adapter.

A 1419
1-phase adapter 16 A,
3 pin male / 16 A
Schuko female, 2 m
1-phase test adapter for, testing of 1 phase exten-
sion leads in combination with A 1322 / Active
3-phase Adapter.

A 1423
Adapter for welding
equipment, 14/CX20
Test adapter for measuring leakage current,
insulation, earth bond and no load voltage on ARC
welding equipment.

A 1424
Adapter for welding
equipment, 21/CX22
Test adapter for measuring leakage current,
insulation, earth bond and no load voltage on ARC
welding equipment.

A 1425
Adapter for welding
equipment, 21/CX25
Test adapter for measuring leakage current,
insulation, earth bond and no load voltage on ARC
welding equipment.

A 1283
Shielded leakage cur-
rent clamp
Current clamp with high resolution for accurate
leakage current measurements.

A 1472
Leakage current
clamp
Current clamp with high resolution for accurate
leakage current measurements.

A 1018
Current clamp (low
range, leakage)
High accuracy current clamp 1000 A / 1 A with jaw
opening 52 mm and xed 1.5 m cable for both load
and low range / leakage current measurement and
for earth resistance measurement as well.

A 1388
Adapter Schuko /
Schuko
Measuring adapter for leakage current measure-
ments: for measuring differential leakage current,
protective conductor current, neutral current and
load current, through leakage current clamp. All
wires are separated.

A 1389
Adapter CEE 5-P 16A
/ CEE 5-P 16A
Measuring adapter for leakage current measure-
ments: for measuring differential leakage current,
protective conductor current, neutral current and
load current, through leakage current clamp. All
wires are separated.

A 1390
Adapter CEE 5-P 32A
/ CEE 5-P 32A
Measuring adapter for leakage current measure-
ments: for measuring differential leakage current,
protective conductor current, neutral current and
load current, through leakage current clamp. All
wires are separated.

A 0941 Remote control pedal
Remote control pedal is used for safe remote
start of high voltage insulation test and addition-
ally allows free hand operation of the worker.

Option Not available
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 36 3. 37 Accessories: page 3.34 Accessories: page 3.34
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 0942 Warning lamp
Warning lamps visually signalizes ongoing HV
insulation test and warns the user about danger-
ous voltage conditions.

A 1421 External buzzer
Acoustics signal for auto-continuity measure-
ment.

A 1059
Insulation and Conti-
nuity adapter
1-phase 16 A CEE plug adapter for insulation re-
sistance and continuity measurements.

A 1060
Power splitter for
discharge time meas-
urement
T-type power splitter for measurements of dis-
charge time on machinery and switchgear.

S 1057
HV test lead, 5 m,
2 pcs
High voltage extension test leads for measure-
ments on larger electrical equipment.

S 1058
Continuity test lead, 2
x 10 m, 2 pcs
Extension test leads for continuity measure-
ments.

S 1072
Continuity test lead
with crocodile clip, 2 x
2.5 m, 2 pcs
Extension test leads with protection shield and
with crocodile clips for continuity testing with high
test currents (10 A, 25 A).

S 2012
Continuity test lead,
10 m, 2 pcs (red,
black)
2 pieces of extension test lead for continuity
measurements.

S 2025
Test lead, 1.5 m, 2
pcs (black, red)
Connection leads for different measurements.
A 1095
Insulation / Subleak-
age adapter
The adapter equipped with CEE 16 A schuko plug
supports insulation resistance and touch leakage
current measurements on Class 1 portable appli-
ances with conductive metal parts.

A 1096
Adapter for perma-
nently wired loads
The adapter allows continuity and insulation re-
sistance measurement on permanently wired
loads (without plug).

A 1447
PRCD Extension
adapter
Adapter for testing of PRCD-S/K, supported from
HW4.

Selection Guide for PAT Accessories
Option Not available
Selection Guide for PAT Accessories
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1153 Test lead, black, 20 m
Extension test lead for earth and continuity
measurements.

A 1154 Test lead, black, 4 m
Extension test lead for earth and continuity
measurements.

A 1331
Test lead with
crocodile clip,
black, 1,5 m
Test lead with crocodile clip for PAT testing.
A 1404
Test lead with test tip,
black, 1,5 m
Earth bond test lead with test tip for PAT testing.
A 1334 IEC cable, 2 m
Additional IEC cable for performing PRCD test
with MI 3309.

A 1341 Test lead, green 1.5 m Test lead for PAT safety testing.
A 1342
Test lead, brown
1.5 m
Test lead for PAT safety testing.
A 1309 Crocodile clip, green
Crocodile clip assures secure and permanent
contact during the measurement on bus bars,
xing screws, etc.

A 1310 Crocodile clip, blue
Crocodile clip assures secure and permanent
contact during the measurement on bus bars,
xing screws, etc.

A 1297 Crocodile clip, brown
Crocodile clip assures secure and permanent
contact during the measurement on bus bars,
xing screws, etc.

A 1013 Crocodile clip, black
Crocodile clip assures secure and permanent
contact during the measurement on bus bars,
xing screws, etc.

A 1064 Crocodile clip, red
Crocodile clip assures secure and permanent
contact during the measurement on bus bars,
xing screws, etc.

Option Not available
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
3. 38 3. 39 Accessories: page 3.34 Accessories: page 3.34
Selection Guide for PAT Accessories
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1062 Test probe, green
Test probe with 4 mm connection is suitable
for performing measurements both in mains out-
lets and in situations when no schuko outlet is
present.

A 1015 Test probe, blue
Test probe with 4 mm connection is suitable
for performing measurements both in mains out-
lets and in situations when no schuko outlet is
present.

A 1298 Test probe, brown
Test probe with 4 mm connection is suitable
for performing measurements both in mains out-
lets and in situations when no schuko outlet is
present.

A 1014 Test probe, black
Test probe with 4 mm connection is suitable
for performing measurements both in mains out-
lets and in situations when no schuko outlet is
present.

A 1016 Test probe, red
Test probe with 4 mm connection is suitable
for performing measurements both in mains out-
lets and in situations when no schuko outlet is
present.

A 1268
Test probe, brush
type, 4 mm
Test probe, brush type, assures good galvanic
contact when measuring on revolving parts,
at surfaces, screw connections and similar.
Equipped with standard 4 mm connector.

A 1276
Label printer with
power and data
cables
Printer supports printing of identication labels
containing a complete appliance information and
PASS or FAIL evaluation of test results.

A 1318
Label printer
(Bluetooth)
Printer supports printing of identication labels
containing a complete appliance information and
PASS or FAIL evaluation of test results.

S 2062 BT lable printer set
Printer supports printing of QR codes which con-
tain information of the previous results, the test
status, and the previously used test sequence.

A 1295 Spare label roll Spare label rolls for printer A 1276 and A 1318.
A 1328 Hi-Q DT labels
High quality spare label rolls for printer A 1276
and A 1318.

A 1379
Paper for A 1276,
A 1318 printers
Spare thermal receipt paper for printer A 1276
and A 1318.

Option Not available
Selection Guide for PAT Accessories
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1450
Spare label role for
S 2062
Spare thermal receipt paper for printer S 2062.
A 1359
Thermal printer clean-
ing kit
Cleaning Kit for printers A 1276 and A 1318
which includes 25 Cleaning Cards and 25 Adhe-
sive Removers.

A 1061 Barcode scanner
Barcode scanner for identication of barcodela-
belled appliances (for MI 2094 HW1 and HW2).

A 1105 Barcode scanner
Barcode scanner for identication of barcodela-
belled appliances.

A 1321
Barcode scanner
(Bluetooth)
Barcode scanner for identication of barcodela-
belled appliances.

A 1106
Barcode labels, 1000
pcs
Appliances can be marked with barcode labels
for easier identication.

A 1107 RFID reader / writer
RFID reader / writer allows to read and upload
test results and informaton about tested electri-
cal equipment to the RFID tags.

A 1108
RFID tags, self stick,
25 pcs
RFID tags, key tag,
25 pcs
RFID tags sufcient memory space to store test
results and tested appliance information.

A 1337
RFID tags, self-stich
50 pcs
RFID tags have sufcient memory space to store
test results and tested appliance information.

A 1160
Fast charger for 8 AA
batteries with a set of
6 NiMH bat., type AA
Fast battery charger for up to 8 pieces of AA re-
chargeable batteries, and a set of 6 pcs NiMH
rechargeable batteries, type AA.

A 1169
Fast charger for AA,
C, D and 9 V block
batteries
Fast battery charger for up to 12 pcs AA, 6 pcs
C or D rechargeable batteries, 4 pcs 9 V block
batteries.

A 1017
Communication cable
RS232
RS232 interface cable for connecting the instru-
ment with the PC.

Option Not available
Accessories: page 4.24
Appliance / Machine / Switchboard Safety
3. 40 Accessories: page 3.34
Photo
Part
number
Description Target application
M
I

3
3
0
5
M
I

3
3
0
4
M
I

3
3
1
0

2
5
A
M
I

3
3
1
0
M
I

3
3
0
9

B
T
M
I

3
3
1
1
M
I

2
1
4
2
A

1
3
2
2
A

1
4
2
2
M
I

2
0
9
4
M
I

3
3
2
1
M
I

2
1
7
0
A 1171
RS232 / USB adapter
with 1 m cable
RS232 / USB adapter for instruments without
USB comunication port.

A 1073
PC SW CE Link with
RS232 cable
PC SW CE Link is a multi-purpose software for pro-
gramming of the MI 2094, test data downloading
and evaluation and creation of test reports.

A 1203
Upgrade code
PATLink PRO to
PATLink PRO Plus
Password for upgrading standard PC software
PATLink PRO to advanced PC SW PATLink PRO
Plus with professional report creation facility.

A 1305
PC SW PATLink PRO
with USB and RS232-
PS/2 cable
PC Software PATLink PRO enables downloading,
data management and printing of test reports.
Comes delivered with RS232-PS/2 and USB com-
munication cables.

A 1306
PC SW PATLink PRO
Plus with USB and
RS232-PS/2 cable
PATLink PRO Plus is an advanced PC SW which
enables downloading, test results analysis, data
upload to the instrument and professional test re-
port creation. Delivered with RS232 and USB COM
cables.

A 1433 PATLink Android
PATLink Android enables fast and simple data man-
agement of tested appliances, as well as a quick
overview of already performed tests by simply
scanning a QR code.

A 1434 aPATLink Android
PATLink Android enables fast and simple data man-
agement of tested appliances, as well as a quick
overview of already performed tests by simply
scanning a QR code.

A 1436 Bluetooth dongle
External Bluetooth adapter for wireless connec-
tion between Metrels instruments and Smart
phones, tablets and PCs.

A 1271
Small soft carrying
bag
Small soft carrying bag for transport and storage
of test instrument or accessories.

A 1289 Soft carrying bag
Large soft carrying bag for transport and storage
of test instrument and belonging accessories.

A 1302 Set of carrying straps
Set of carrying straps for carrying the measuring
instrument around the neck allowing free hand
use of the tester.

A 1303 Soft hand strap Soft hand strap for holding the instrument.
Selection Guide for PAT Accessories
Option Not available
GOOD TO KNOW
Power Quality Analysis 4 - 02
Selection Guide for Power Quality Analysers 4 - 04
Selection Guide for Clamps 4 - 06
MI 2892 PowerMaster NEW 4 - 08
MI 2792A PowerQ4 Plus 4 - 10
MI 2792 PowerQ4 Plus 4 - 12
MI 2592 PowerQ4 4 - 14
MI 2392 PowerQ
Plus
4 - 16
MI 2492 PowerQ 4 - 18
MI 2130 VoltScanner 4 - 20
PC SOFTWARE
PowerView3 4 - 22
Selection Guide for Accessories 4 - 24
P
o
w
e
r

Q
u
a
l
i
t
y

A
n
a
l
y
s
i
s

P
o
w
e
r
,

E
n
e
r
g
y
,

V
o
l
t
a
g
e
,

P
o
w
e
r

F
a
c
t
o
r

a
n
d

E
N

5
0
1
6
0

A
n
a
l
y
s
i
s
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
Power Quality Analysis
Power Quality Analysis Power Quality Analysis
4. 2 4. 3 Accessories: page 4.24 Accessories: page 4.24
Power Quality Testing Power Quality Testing
GOOD TO KNOW GOOD TO KNOW
Find out more about modern power
quality measurement techniques
There are quite a few reasons for meas-
uring and analysing power quality nowa-
days. Potential interactions between
end use equipment and electric distribu-
tion system, external electromagnetic
interferences, resonant states between
electrical circuits and some other factors
call for a need to be analysed in order
that harmful consequences can be omit-
ted or prevented.
Power quality analysing includes meas-
urements of:
Phase to ground voltages;
Phase to neutral voltages;
Neutral to ground voltages;
Phase to phase voltages in three-
phase systems;
Phase currents;
Current in a neutral conductor;
Frequency;
Power Factor, cos ;
Harmonic components of current and
voltage and their direction;
Waveform of current and voltage at
specic circumstances (peak magni-
tude, primary frequency, time of oc-
currence, rising rate);
Transients.
Active Power (P)
Active power is the power generated if a
voltage is placed over a purely resistive
load and current is allowed to ow. Ac-
tive power is usually measured in watts
(W) or kilowatts (kW).
Reactive Power (Q)
Reactive power is the power that is
generated by reactive components (e.g.
inductors, capacitors) to create a mag-
netic eld. This is usually measured in
Volt-Ampers reactive (VAr).
Apparent Power (S)
Apparent power is the perceived power
from a load that has both resistive and
reactive components. Apparent power
is the vector sum of both active and re-
active power and is usually measured in
Volt-Amperes (VA).
Power Factor
Power factor is a measure of a power
systems efciency and is the ratio of
real power to apparent power.
Energy
Energy is the generation or use of elec-
tric power over a period of time. This
is usually expressed in kilowatt-hours
(kWh).
Fundamental frequency
The fundamental frequency is the low-
est and most predominant frequency in
a power system (e.g. the fundamental
frequency of the mains voltage in the EU
is 50 Hz). The fundamental frequency is
also called the 1
st
harmonic of the sys-
tem.
Voltage events
Dips
Supply voltage dip represents tem-
porary drops of the voltage under the
nominal level.
Swells
Supply voltage swells are instantaneous
voltage increases (opposite to dips).
Interruptions
Voltage interruption is classied as a
networks isolation from any source of
supply.
Unbalance
Supply voltage unbalance arises when
rms values or phase angles between
consecutive phases are not equal.
Harmonics
Harmonics are integer frequency multi-
plication of the fundamental frequency
(e.g. with a fundamental of 50 Hz, the 2
nd

harmonic is 50 x 2 = 100 Hz, 3
rd
harmon-
ic is 50 x 3 = 150 Hz). Harmonics can be
caused by a variety of modern day equip-
ment including resonating transformers,
switch-mode power supplies, IT equip-
ment, etc.
Interharmonics
Interharmonics are harmonics that are
not an integer multiplication of the fun-
damental frequency. The main sources
of interharmonic waveform distortion
are static frequency converters, induc-
tion motors and arcing devices.
Total Harmonic Distortion (THD)
THD is the ratio of a waves harmonic
content (for voltage or current) to its fun-
damental component.
Transients
Transient is a term for short, highly
damped momentary voltage or current
disturbance. They usually appear as a
consequence of external electromag-
netic interferences (atmospheric electric
discharges, switching manoeuvres).
Flickers
Flicker appears as changing illumination
intensity which is a reection of a chang-
ing voltage level.
Inrush current
As a motor begins the current needed to
start the motor can be 10 to 15 times the
normal operating current. This initial surge
of current can cause dips in voltage and
can be hard to analyse with normal test
instruments, for this reason an analyser
with a fast logging function is required.
Instrument connection to the LV and
MV Power Systems
When connecting the instrument it is
essential that both current and voltage
connections are correct. In particular the
following rules have to be observed:
Current clamp-on current transformers
The arrow marked on the clamp-on
current transformer has to point in the
direction of current ow, from supply
to load;
If the clamp-on current transformer is
connected in reverse the measured
power in that phase would normally
appear negative.
Phase relationships
The clamp-on current transformer
connected to current input connector
I1 has to measure the current in the
phase line to which the voltage probe
from L1 is connected.
In case of events capturing, it is recom-
mended to connect unused voltage in-
puts to N voltage input.
Connection to 1-phase 3-wire system
Connection to 3-phase 3-wire system
Connection to 3-phase 4-wire system
Connecting instrument to the existing current transformers
in medium voltage system
Recommended Recording Practice
Power quality measurements are spe-
cic type of measurements, which can
last several days or even up to several
weeks. Usually recording campaign is
performed to:
Statistically analyze some point in the
network.
Troubleshoot malfunctioning device or
machine.
Mostly long-term measurements are
performed only once, so why it is very
important to properly set measuring
equipment. Measuring with wrong set-
ting can lead to false or useless meas-
urement results. In the following ow
chart recommended recorder procedure
is shown (with MI 2792 PowerQ4 Plus
instrument).
Power quality improvement
Captured with Power Analyser data can
be used for improvement of supplied
power quality. There are different ways
to increase efciency of power supply.
Cutting power peaks
One of the simplest and the most ef-
cient way to decrease the electricity
power bill is by lowering peaks of con-
sumed power (peak demand). This can
be achieved by:
reorganization of production processes;
embedded generation.
The rst solution can be implemented
in systems where some tasks can be
stopped or rescheduled.
The second solution can be implemented
in systems with generators that are often
used as a back-up power supply.
Both solutions require additional moni-
toring and control systems that are de-
signed upon previously conducted meas-
urement and analysis of the situation in
the eld. Another possibility to increase
efciency is by increasing the power fac-
tor using corrective techniques.
Capacitor Banks
Capacitor banks are the devices most sus-
ceptible to the presence of harmonics.
Since consumers loads usually have in-
ductive characteristics, capacitor banks
are used for compensation of inductive
currents. This feature allows:
better overall system performance;
increasing availability of active power;
decreasing transmission loses;
increasing voltage;
decreasing nancial penalty because
of poor power factor.
EN 50160 Standard Overview
EN 50160 is one of the most important
standards in eld of power quality which
denes, describes and species the
main characteristics of the voltage at a
network users supply terminals in public
low voltage and medium voltage distri-
bution networks under normal operating
conditions. This standard describes the
limits or values within which the volt-
age characteristics can be expected to
remain over the whole of the public dis-
tribution network and does not describe
the average situation usually experi-
enced by an individual network user.
In
O
f

c
e
O
n
M
e
a
s
u
r
in
g
s
it
e
In
O
f

c
e
Prepare instrument
for new measurement
before going to meas-
uring site. Check:
Are time and date
correct?
Are batteries in good
condition?
Is the Memory
List empty? If it is
not, download all
data from previous
measurements and
release storage for
new measurement.
Step 1:
Instrument Setup
Set Time & Date
Recharge batteries
Clear memory
Step 7:
Report generation (PowerView3)
Download data
Analyse data
Export to Excel or Word
Step 6:
Measurement conclusion
Stop recorder
Power off instrument
Remove wiring
Analyze recorder data with instrument
(Memory list, Event and Alarm tables)
Step 2:
Measurement Setup
START
Step 2.1:
Sync. & wiring
Conn.Type
(4W,3W,1W)
Sync channel
U1I1IU12
Step 2.3:
Clamps setup
Clamp type
Clamp ratio
Step 2.2:
Voltage range & ratio
Voltage range
Voltage ratio
Step 2.4: (Optional)
Event Setup
Nominal voltage
Thresholds
Step 2.5: (Optional)
Alarm Setup
Dene alarm and
its parameters
Setup instrument ac-
cording to the meas-
urement point nominal
voltage, currents, load
type. Optionally en-
able events or alarms
and dene parameter
thresholds.
Double check Meas-
urement setup using
Phase diagram, and
various scope and me-
tering screens.
Using power meter
check if power is
owing in right direc-
tion (power should be
positive for load and
negative for generator
measurements).
Step 3:
Inspection
Phase diagram
U,I,f meter screen
Power meter screen
Step 4:
On Line Measurement
Perform measure-
ment
Save waveform
snapshots
Step 5: (Optional)
Recorder setup
Select signals for
recording
Dene recording
start time, duration
and interval
Start
recording
Power Quality Analysis Power Quality Analysis
4. 4 4. 5 Accessories: page 4.24 Accessories: page 4.24
Selection Guide for Power Quality Analysers Selection Guide for Power Quality Analysers
Part No.
NEW MI 2892 MI 2792A MI 2792 MI 2592 MI 2392 MI 2492 MI 2130
PowerMaster PowerQ4 Plus PowerQ4 Plus PowerQ4 PowerQ
Plus
PowerQ VoltScanner
INPUTS
Number of current measuring inputs 4 4 4 4 3 3
Number of voltage measuring inputs 4 4 4 4 3 3 1
Automatic Smart Clamp detection (Smart range selection)
MEASUREMENTS
TRMS Current measurement (Min., Max., Avg.)
TRMS Voltage measurement (Min., Max., Avg.) (rms only)
Scope function
On-line harmonics measurement
Frequency measurement
Power measurement (W, VA, VAr)
THD and harmonics analysis
Interharmonics analysis
Power Factor and cos
Registration of voltage events (sags, swells, interruptions)
Statistical evaluation
Current in neutral conductor calculated value calculated value
Phase diagram
Unbalance
EN 50160 Analysis
(without icker
measurement)
(without icker
measurement)
1-phase, without icker
measurement
Flicker measurement
Transients measurement (without triger, Level) (without triger, Level) 1-phase, voltage transients
Waveform recording (snapshot) (snapshot) (snapshot)
Inrush currents
Energy measurement
Signalling
Temperature measurement
Integration period 1 ... 3600 s 1 ... 3600 s 1 ... 3600 s 1 ... 3600 s 1 ... 3600 s 1 ... 3600 s 1 ... 1260 s
Power measurements in compliance with IEEE 1459
Simultaneous General/waveform/inrush
Colour coding
COMMUNICATION PORTS
USB Option
RS232
GPS time sinhronisation Option
Remote instruments control (GPRS) Option Option
Remote instruments control (Ethernet)
GENERAL
Graphical LCD with backlight 480 x 272 4.3 inch color TFT 320 x 200 dots 320 x 200 dots 320 x 200 dots 320 x 200 dots 320 x 200 dots
On-site analysis of recorded data
Built-in power supply for exible clamps
Maximal recording time Over a year 4 ... 8 weeks 4 ... 8 weeks 4 ... 8 weeks 4 ... 8 weeks 4 ... 8 weeks 2 ... 4 weeks
Memory module size 8 GB supplayed, up to 32 GB 8 MB 8 MB 8 MB 8 MB 8 MB 32 kB
PC Sofware
Maximal test voltage interphase value 1730 V rms 1730 V rms 1730 V rms 1730 V rms 952 V rms 952 V rms 265 V rms
Maximal test voltage between phase and PE conductors 1000 V rms 1000 V rms 1000 V rms 1000 V rms 550 V rms 550 V rms 265 V rms
Frequency range 10 ... 70 Hz 10 ... 70 Hz 10 ... 70 Hz 10 ... 70 Hz 45 ... 66 Hz 45 ... 66 Hz 47 ... 62 Hz
Over voltage category
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V CAT IV / 600 V CAT III / 300 V
AC power supply
Built-in battery charger
Rechargeable batteries (NiMH) 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 4 x AA
Battery life (tipically) 6 h 15 h 15 h 15 h 15 h 15 h 180 h
Weight 0.96 kg 0.65 kg 0.65 kg 0.65 kg 0.65 kg 0.65 kg 0.51 kg
Dimensions (mm) 230 x 140 x 80 220 x 115 x 90 220 x 115 x 90 220 x 115 x 90 220 x 115 x 90 220 x 115 x 90 103 x 51 x 199
Power Quality Analysis Power Quality Analysis
4. 6 4. 7 Accessories: page 4.24 Accessories: page 4.24
Highly recommended Compatible
Selection Guide for Clamps
Part No.
Smart
Clamps
Description Target application MI 2892 MI 2792A MI 2792 MI 2592 MI 2392 MI 2492
A

1
2
8
1

Current clamp
0.5/5/100/1000 A
/ 1 V
High accuracy current clamp 0.5/
5/100/1000 A / 1 V for precise current
and power measurements including
leakage current measurement.
* *
A

1
0
3
3

Current clamp
1000 A / 1 V
High accuracy current clamp 1000 A
/ 1 V with jaw opening 52 mm and
xed 1.5 m cable for power meas-
urements with Metrel power quality
analysers.

A

1
1
2
2

Mini current
clamp
5 A / 1 V
Mini current clamp 5 A / 1 V with jaw
opening 15 mm for power measure-
ments. Requires A 1039 connection
cable.

A

1
0
6
9

Mini current
clamp
100 A / 1 V
Mini current clamp 100 A / 1 V with
jaw opening 15 mm for power meas-
urements. Requires A 1039 connec-
tion cable.

A

1
2
2
7

1-phase exible
current clamp
3000/300/30 A
/ 1 V
Single phase exible current clamp
with three selectable measuring rang-
es. Does not require external power
supply as it is powered by the measur-
ing instrument.
* *
A

1
4
4
6

1-phase exible
current clamp
6000/600/60 A
/ 1 V
Single phase exible current clamp
with three selectable measuring
ranges. Does not require external
power supply as it is powered by the
measuring instrument.
* *
A

1
2
5
7

3-phase exible
current clamp
3000/300/30 A
/ 1 V
3-phase exible current clamp with
three selectable measuring ranges.
Powered by alkaline or rechargeable
batteries.

A

1
2
8
7

1-phase exible
current clamp
3000/300/30 A
/ 1 V
Single phase exible current clamp
with three selectable measuring
ranges. Powered by alkaline or re-
chargeable batteries.

A

1
1
7
9

3-phase exible
current clamp
2000/200/20 A
/ 1 V
3-phase exible current clamp with
three selectable measuring ranges.
Powered by alkaline or rechargeable
batteries.

A

1
0
3
7

Current
transformer
5 A / 1 V
3-phase transformer for power
measurements on distribution pan-
els with 5 A nominal output current.

*MI 2492, MI 2392 supported from HW4 / FW9.2
SMART CLAMPS KEY FEATURES:
Cover wide current range;
Are automatically recognized by the instrument;
Are switchless (range selection on the instrument);
Do not require external power supply.
Selection Guide for Clamps
Part No. Type
Jaw
opening
Ranges
Measurement
Ranges
RMS
accuracy
50 Hz
Phase
accuracy
50 Hz
RMS
accuracy
1500 Hz
Phase
accuracy
1500 Hz
Overvoltage
category; IP
A

1
2
8
1
Iron 52 mm
0.5 A
5 A
100 A
1000 A
10 mA ... 1 A
0.5 A ... 10 A
10 A ... 175 A
100 A ... 1200 A
0,5 %
0,5 %
0,5 %
1,2 %
< 0.5 1.5 % < 1.5
CAT III / 600 V;
IP 20
A

1
0
3
3
Iron 52 mm
1000 A
100 A
50 A ... 1200 A
5 A ... 200 A*
2 %
3 %
< 2 3.5 % < 3
CAT III / 600 V;
IP 20
A

1
1
2
2
Iron 15 mm
5 A
0.5 A
250 mA ... 10 A
25 mA ... 1 A*
2 %
2 %
< 6 3 % < 6
CAT III / 600 V;
IP 20
A

1
0
6
9
Iron 15 mm
100 A
10 A
5 A ... 200 A
500 mA ... 20 A*
2 %
2 %
< 3 3 % < 2
CAT III / 600 V;
IP 20
A

1
2
2
7
Flex 14 cm
30 A
300A
3000 A
3 A ... 60 A
10 A ... 600 A
60 A ... 6000 A
1 %
1 %
1 %
< 1 3 % < 10
CAT III / 600 V;
IP 64
A

1
4
4
6
Flex 27 cm
60 A
600A
6000 A
6 A ... 120 A
20 A ... 1200 A
120 A ... 12000 A
1 %
1 %
1 %
< 1 3 % < 10
CAT III / 600 V;
IP 64
A

1
2
5
7
Flex 14 cm
30 A
300 A
3000 A
3 A ... 60 A
10 A ... 600 A
60 A ... 6000 A
1 %
1 %
1 %
< 1 3 % < 10
CAT III / 600 V;
IP 64
A

1
2
8
7
Flex 14 cm
30 A
300 A
3000 A
3 A ... 60 A
10 A ... 600 A
60 A ... 6000 A
1 %
1 %
1 %
< 1 3 % < 10
CAT III / 600 V;
IP 64
A

1
1
7
9
Flex 14 cm
20 A
200 A
2000 A
2 A ... 40 A
7 A ... 400 A
40 A ... 4000 A
1 %
1 %
1 %
< 1 3 % < 10
CAT III / 600 V;
IP 64
A

1
0
3
7
Iron N/A
0.5 A
5 A
10 mA ... 1 A
0.5 A ... 10 A*
0,3 %
0,3 %
< 0.5 1 % < 1.0
CAT III / 600 V;
IP 40
*Range is available only on PowerQ series instruments: MI 2492, MI 2392, MI 2592, MI 2792, MI 2792A and MI 2892.
Power Quality Analysis Power Quality Analysis
4. 8 4. 9 Accessories: page 4.24 Accessories: page 4.24
MI 2892 PowerMaster
MEASURING FUNCTIONS:
Voltage: TRMS, peak, crest factor
(4-channel);
Current: TRMS, peak, crest factor
(4-channel);
Power (active, reactive, apparent);
Power measurements fully compli-
ant with IEEE 1459 (active, nonactive,
fundamen tal, harmonic, load unbalance);
Unbalance, icker measurement;
Harmonic and interharmonic analysis up
to 50th harmonics, THD measurement;
Energy (active, reactive, generated,
consumed);
Capturing and recording of power sup-
ply events (shutdowns, interruptions,
swells, dips);
Inrush currents monitoring and recording;
Waveform/inrush displaying, snapshot
and recording;
Transients recording;
Power quality analysis according to EN
50160;
Recording up to 7 adjustable alarms;
Temperature measurement;
Power factor cos .
KEY FEATURES:
4-voltage channels with wide meas-
urement range: 0 ... 1000 Vrms (CAT
III / 1000 V);
4-current channels with support for
automatic clamp recognition and on
instrument range selection;
Automatic Smart Clamp detection and
Smart Clamp range selection;
Sampling frequency on transients re-
cording > 50 kHz;
Compliance with power quality stand-
ard IEC 61000-4-30 Class A;
Complete power quality analysis ac-
cording to EN 50160 including signal-
ling and interharmonics;
Support for microSD memory card (8-
GB supplied with the instrument) up to
32GB;
Color-coded input terminals and termi-
nal labels to suit your application region;
Intuitive main menu and large icons
The MI 2892 PowerMaster is a hand-held three phase power quality ana lyser with a large easy-to-read graphical colour
display enabling the user to detect harmonics, phasors and waveforms anomalies in the installation simply by con necting
the device. The instrument is designed for a long term recording as well as for troubleshooting power quality problems in
three-phase and single-phase power distribution systems. The handy Quick Set buttons makes the instrument more user
friendly and are allowing faster data overview for troubleshooting. Advanced PC SW package PowerView3 enables detailed
analysis of recorded data, direct reading from the microSD memory card, analysis of long term records and automatic crea-
tion of professional test report.
that makes the equipment very easy
to navigate and configure;
Powerful PC SW PowerView3 ena-
bles downloading, view, analysis of
recorded data and professional report
creation;
Flexible clamps (without additional
power supply) are included in the
stand ard set;
Remote communication via Ethernet
(GPS clock synchronization - optional).
APPLICATION:
Power quality assessment and trou-
bleshooting in low and middle voltage
electrical systems;
Checking power correction equipment
STANDARD SET:
MI 2892
Instrument PowerMaster
1-phase exible current clamps 3000 / 300
/ 30 A
(A 1227), 4 pcs
Test probe, (brown, black, grey, green,
blue), 5 pcs
Crocodile clip, (brown, black, grey, green,
blue), 5 pcs
Voltage measurement lead, (brown, black,
grey, green, blue), 5 pcs
Temperature probe
microSD memory card 8.0GB
PC SW PowerView3
RS232, USB and Ethernet patch cable
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
TECHNICAL SPECIFICATION:
performance;
Long-term analysis;
Predictive maintenance;
Verication of electrical system capac-
ity before adding loads.
STANDARDS:
Functionality: IEC/EN 61000-4-30,
Class A; IEC/EN 61557-12; IEC/EN
61000-4-7, Class I; IEC/EN 61000-4-15;
EN 50160; IEEE 1448; IEEE 1459
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1
Function
Voltage inputs
Number of inputs
Nominal voltage range (L N)
Measuring range
Accuracy
Sampling rate
Mains frequency range
AC/DC
4
Phase (L-N): 50 1000 Vrms / Line (L-L): 50 1730 Vrms
10% 150% of nominal voltage
IEC 61000-4-30 Class A, 0.1% of nominal voltage,
5.120 kSamples per sec 50/60 Hz, sync with mains freq.
40 70 Hz 10 mHz
Current inputs
Number of inputs
Measuring range
(with A1227 ex clamps)
Measuring range
(with A1281 iron clamps)
AC/DC
4
3 6000 Arms 1.5% of m.v.
50 m 1200 Arms 0.5% of m.v.
Functions Measuring range Accuracy
Power (P, Q, S, cos , PF) Depends on voltage and selected clamps IEC 61557-12 Class 1
Energy Depends on voltage and selected clamps
Active: IEC 62053-21 Class 1
Reactive: IEC 62053-23 Class 2
Harmonics (DC 50th) 0 20% of nom. voltage IEC 61000-4-7 Class 1
Interharmonics (1 50th) 0 20% of nom. voltage IEC 61000-4-7 Class 1
Flicker 0.2 10 IEC 61000-4-15 Class F3
Mains signalling 0 15% of nom. voltage IEC 61000-4-30 Class A
Unbalance
Voltage: 0 5%
Current: 0 17%
Temperature -10 85 C 0.5 C
Dips, Swell 10 150% of nom. voltage
0.2 % of nominal voltage
1 cycle
Interrupts 0 10% of nom. voltage 1 cycle
Recorders
Memory 8GB microSD, up to 32GB supported
General recorder
Integration period
Recorded signals
Duration
1s 1h
> 1000 (voltages, currents, harmonics, power)
Minimal, maximal and average value per interval
- Voltage events
- Custom alarms
> 1 year (depends on size of SD card)
Waveform recorder
Duration
Trigger
Up to 20 seconds of voltage and current waveform
Manual, Voltage Events, Custom Alarms, voltage or current level (inrush)
Transient revorder
Sampling rate
Duration
Trigger
> 50ksamples/sec
Up to 50 cycles of voltage and current waveform
Manual, voltage envelope or level
General
Display
Communication
Time synchronisation
Power supply
Overvoltage category
Weight
Dimensions
4.3 inch color TFT (480 x 272)
USB, Ethernet, RS-232
GPS receiver (A 1355)
110 240 Vac or 6 x NiMh rechargable batteries, size AA
CAT IV / 600 V or CAT III / 1000 V
1 kg
230 x 140 x 80 mm
Power Quality Analysis Power Quality Analysis
4. 10 4. 11 Accessories: page 4.24 Accessories: page 4.24
MI 2792A PowerQ4 Plus
MEASURING FUNCTIONS:
Voltage: TRMS, peak, crest factor
(4-channel);
Current: TRMS, peak, crest factor
(4-channel);
Power (active, reactive, apparent);
Power factor, cos ;
Unbalance, icker measurement;
Harmonic and interharmonic analysis up
to 50
th
harmonics, THD measurement;
Energy (active, reactive, generated,
consumed);
Capturing and recording of power sup-
ply events (shutdowns, interruptions,
swells, dips);
Inrush currents monitoring and recording;
Waveform displaying, snapshot and
recording;
Transients recording;
Power quality analysis according to EN
50160;
Recording up to 10 adjustable alarms;
Temperature measurement.
KEY FEATURES:
4 voltage channels with wide meas-
urement range: 0 ... 1000 Vrms (CAT
III / 1000 V).
4 current channels with support for
automatic clamp recognition and on
instrument range selection.
Compliance with power quality stand-
ard IEC 61000-4-30 Class A.
Power measurements compliance with
IEC 61557-12 and IEEE 1448 standards.
Complete power quality analysis ac-
cording to EN 50160 including signal-
ling and interharmonics.
Capture of voltage events and user de-
ned alarms.
4-quadrant measurements (generator
and load with capacitive or inductive
character).
Up to 524 parameters can be moni-
tored or recorded simultaneously.
8 MB of internal memory space allows
recording over 4 weeks.
Powerful troubleshooting tools: transient,
inrush / fast and waveform recording.
On-screen displaying of trends and
captured events and simultaneous re-
cording in the background.
The MI 2792A PowerQ4 Plus is top of the range power quality analyser. With its 4 current and 4 voltage channels it is suitable
for locating, predicting and troubleshooting of problems in three and in single phase power distribution systems. All 4 cur-
rent channels have the ability to automatically recognize clamps whose range can be set on the instrument. Rugged design
makes it appropriate for field use. It can operate up to 15 hours on a single battery charge. Parameters of the instrument can
be set directly on the instrument, via the PowerView3 software or remotely true the optional GPRS modem connection. It is
compliant with power quality standard IEC 61000-4-30 Class A, and it has a predefined recorder profile for EN 50160 survey.
Temperature probe for measurement
of the temperature of the tested trans-
former, capacitor bank, etc.
Possibility of remote control of the instru-
ment or group of them via GPRS modem.
Flexible clamps (without additional power
supply) are included in the standard set.
15 hours of autonomous (battery) supply.
Powerful PC SW PowerView3 enables
downloading, view, analysis of recorded
data and professional report creation.
STANDARDS:
Functionality: IEC/EN 61000-4-30,
Class A; IEC/EN 61557-12; IEC/EN
61000-4-7, Class I; IEC/EN 61000-4-15;
EN 50160; IEEE 1448
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1
IEC 61000-4-30 CLASS A :
IEC 6100-4-30 Class
Measurement aggregation over time
intervals
Aggregation algorithm
A
S
Magnitude of the Supply L-N Voltage
magnitude
L-L Voltage magnitude
A
S
Dips and Swells L-N Voltage
magnitude
L-L Voltage magnitude
A
S
Real time clock uncertainty A
Frequency A
Flicker* A
Interruptions A
Unbalance A
Voltage Harmonics A
Voltage Interharmonics A
Mains signalling voltage A
* Class A in range 4951 Hz, see Instruction Manuals for details.
STANDARD SET:
MI 2792A
Instrument PowerQ4 Plus
1-phase exible current clamps 3000 / 300
/ 30 A (A 1227), 4 pcs
GPS receiver
Test probe, red, 3 pcs
Test probe, black
Crocodile clip, black
Crocodile clip, green
Crocodile clip, red, 3 pcs
Voltage measurement lead, red, 3 pcs
Voltage measurement lead, black
Voltage measurement lead, green
Temperature probe
PC SW PowerView3
RS232 and USB cables
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
TECHNICAL SPECIFICATION:
Function
AC Voltage inputs
Number of inputs
Input voltage range
Basic accuracy
Resolution
Sampling rate
Frequency range
4
20 1500 Vrms L - N (20 2600 Vrms L - L)
0.1% of nominal voltage (Unom: 50 ... 1000 Vrms)
10 mV, 100 mV
1024 samples per 10 periods
10 70 Hz
AC Current inputs
Number of inputs
Input voltage range
Current measuring range
Resolution
Basic accuracy
Sampling rate
4
20.0 mVrms 2 Vrms
100 6000 A (depending on clamps)
100 mV
0.25 % of reading
1024 samples per 10 periods
Function Measuring range Resolution Accuracy
Frequency 10.00 70.00 Hz 2 mHz 10 mHz
Power (W, VA, VAR) 0.000 k 9.999 M 4 digits 0.5 % of reading
Power factor -1.00 1.00 0.01 0.02
cos 0.00 1.00 0.01 0.02
Harmonics analysis up 50
th
component
UhN < 1 %Unom
1 %Unom < UhN < 20 %Unom
IhN < 10 %IN
10 %IN < IhN < 100 %IN
10 mV
10 mV
10 mV
10 mV
0.15 %Unom
5 %UhN
0.15 %IN
5 %IhN
THD
0 %Unom < THDU < 20 %Unom
0 %IN < THDI < 100 %IN
100% IN < THDI < 200 %IN
0.1%
0.1%
0.1%
0.3
0.6
1.5
Signalling
1 %UN < USig < 3 %UN
3 %UN < USig < 20 %UN
10 mV
10 mV
0.15 %UN
5 %USig
Voltage dips and swells
Magnitude
Duration
20 1500 V
30 ms 7 days
10 mV, 100 mV
1 ms
0.2 % Unom
1 cycle
Temperature
-20 C ... -10 C
-10 C ... +85 C
+85 C ... +125 C
0.1 C
0.1 C
0.1 C
2.0 C
0.5 C
2.0 C
Recording
General recorder
Records up to 524 parameters (min, max, avg)
Duration: 1 sec ... 99 days
Integration interval: 1 sec ... 60 min
Trigger: Manual, Time
Waveform recorder
Records up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: 1 cycle period up to 3770 cycle periods
Sampling: 5120 samples / sec (for 50 Hz signals)
Trigger: Manual, Event or Alarm Table
Inrush / Fast recorder
Records up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: 1 sec ... 3 min
Sampling: 1 reading per half-cycle up to 1 reading per 10-cycle
Trigger: Manual, Current or Voltage Threshold
Transient recorder
Record up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: up to 47 periods
Sampling: 51200 samples / sec (for 50 Hz signals)
Trigger: Manual, Voltage Envelope (dV)
COM port RS232 and USB
Display Graphic LCD with backlight, 320 x 200 dots
Memory module 8 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
Over voltage category CAT III / 1000 V; CAT IV / 600 V
Protection class Double insulation
Dimensions 220 x 115 x 90 mm
Weight 0.65 kg
Power Quality Analysis Power Quality Analysis
4. 12 4. 13 Accessories: page 4.24 Accessories: page 4.24
MI 2792 PowerQ4 Plus
MEASURING FUNCTIONS:
Voltage: TRMS, peak, crest factor
(4-channel);
Current: TRMS, peak, crest factor
(4-channel);
Power (active, reactive, apparent);
Power factor, cos ;
Unbalance, icker measurement;
Harmonic and interharmonic analysis up
to 50
th
harmonics, THD measurement;
Energy (active, reactive, generated,
consumed);
Capturing and recording of power sup-
ply events (shutdowns, interruptions,
swells, dips);
Inrush currents monitoring and recording;
Waveform displaying, snapshot and
recording;
Transients recording;
Power quality analysis according to EN
50160;
Recording up to 10 adjustable alarms;
Temperature measurement.
KEY FEATURES:
4 voltage channels with wide meas-
urement range: 0 ... 1000 Vrms (CAT
III / 1000 V).
4 current channels with support for
automatic clamp recognition and on
instrument range selection.
Compliance with power quality stand-
ard IEC 61000-4-30 Class S/A.
Power measurements compliance with
IEC 61557-12 and IEEE 1448 standards.
Complete power quality analysis ac-
cording to EN 50160 including signal-
ling and interharmonics.
Capture of voltage events and user de-
ned alarms.
4-quadrant measurements (generator
and load with capacitive or inductive
character).
Up to 524 parameters can be moni-
tored or recorded simultaneously.
8 MB of internal memory space allows
recording over 4 weeks.
Powerful troubleshooting tools: transient,
inrush / fast and waveform recording.
On-screen displaying of trends and
captured events and simultaneous re-
cording in the background.
The MI 2792 PowerQ4 Plus is a power quality analyser specially designed for troubleshooting of power systems and de-
vices. Rugged design, long battery autonomy (up to 15 hours), powerful recorders, events and alarms capture, flex current
clamps as standard accessory, remote instrument control via optional GPRS modem, ability to synchronize instruments via
GPS make this instrument unique troubleshooting tool. Advanced PC SW package PowerView3 enables detailed analysis
of recorded data and automatic creation of professional test report. Excellent price / performance ratio, small size, ad-
vanced measurement methods and loggers are undoubted highlights of the MI 2792.
Temperature probe for measurement
of the temperature of the tested trans-
former, capacitor bank, etc.
Possibility of remote control of the in-
strument or group of them via GPRS
modem.
Flexible clamps (without additional power
supply) are included in the standard set.
15 hours of autonomous (battery) supply.
Powerful PC SW PowerView3 enables
downloading, view, analysis of recorded
data and professional report creation.
APPLICATION:
Power quality assessment and trou-
bleshooting in low and middle voltage
electrical systems;
Checking power correction equipment
performance;
Harmonics spectrum analysis for se-
lection of harmonic lters;
UPS, voltage generators and regula-
tors checking and troubleshooting;
Voltage, current, power monitoring
and recording;
Consumption prole recording.
STANDARDS:
Functionality:
IEC/EN 61000-4-30, Class S;
IEC/EN 61557-12;
IEC/EN 61000-4-7, Class II;
IEC/EN 61000-4-15;
EN 50160; IEEE 1448
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1
STANDARD SET:
MI 2792
Instrument PowerQ4 Plus
1-phase exible current clamps 3000 / 300
/ 30 A (A 1227), 4 pcs
Test probe, red, 3 pcs
Test probe, black
Crocodile clip, black
Crocodile clip, green
Crocodile clip, red, 3 pcs
Voltage measurement lead, red, 3 pcs
Voltage measurement lead, black
Voltage measurement lead, green
Temperature probe
PC SW PowerView3
RS232 and USB cables
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
TECHNICAL SPECIFICATION:
Function
AC Voltage inputs
Number of inputs
Input voltage range
Basic accuracy
Resolution
Sampling rate
Frequency range
4
20 1500 Vrms L - N (20 2600 Vrms L - L)
0.2% of reading
10 mV, 100 mV
1024 samples per 10 periods
10 70 Hz
AC Current inputs
Number of inputs
Input voltage range
Current measuring range
Resolution
Basic accuracy
Sampling rate
4
20.0 mVrms 2 Vrms
3 6000 A (for current clamp A 1227)
0.1 mV (0.1 A for current clamp A 1227)
0.25 % of reading
1024 samples per 10 periods
Function Measuring range Resolution Accuracy
Frequency 10.00 70.00 Hz 2 mHz 10 mHz
Power (W, VA, VAR) 0.000 k 9.999 M 4 digits 0.5 % of reading
Power factor -1.00 1.00 0.01 0.02
cos 0.00 1.00 0.01 0.02
Harmonics analysis up 50
th
component
UhN < 3 %Unom
3 %Unom < UhN < 20 %Unom
IhN < 10 %IN
10 %IN < IhN < 100 %IN
10 mV
10 mV
10 mV
10 mV
0.15 %Unom
5 %UhN
0.15 %IN
5 %IhN
THD
0 %Unom < THDU < 20 %Unom
0 %IN < THDI < 100 %IN
100% IN < THDI < 200 %IN
0.1%
0.1%
0.1%
0.3
0.6
1.5
Signalling
1 %UN < USig < 3 %UN
3 %UN < USig < 20 %UN
10 mV
10 mV
0.15 %UN
5 %USig
Voltage dips and swells
Magnitude
Duration
20 1500 V
30 ms 7 days
10 mV, 100 mV
1 ms
0.5 % of reading
20 ms
Temperature
-20 C ... -10 C
-10 C ... +85 C
+85 C ... +125 C
0.1 C
0.1 C
0.1 C
2.0 C
0.5 C
2.0 C
Recording
General recorder
Records up to 524 parameters (min, max, avg)
Duration: 1 sec ... 99 days
Integration interval: 1 sec ... 60 min
Trigger: Manual, Time
Waveform recorder
Records up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: 1 cycle period up to 3770 cycle periods
Sampling: 5120 samples / sec (for 50 Hz signals)
Trigger: Manual, Event or Alarm Table
Inrush / Fast recorder
Records up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: 1 sec ... 3 min
Sampling: 1 reading per half-cycle up to 1 reading per 10-cycle
Trigger: Manual, Current or Voltage Threshold
Transient recorder
Record up to 8 parameters (U1 ... UN, I1 ... IN)
Duration: up to 47 periods
Sampling: 51200 samples / sec (for 50 Hz signals)
Trigger: Manual, Voltage Envelope (dV)
COM port RS232 and USB
Display Graphic LCD with backlight, 320 x 200 dots
Memory module 8 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
Over voltage category CAT III / 1000 V; CAT IV / 600 V
Protection class Double insulation
Dimensions 220 x 115 x 90 mm
Weight 0.65 kg
Power Quality Analysis Power Quality Analysis
4. 14 4. 15 Accessories: page 4.24 Accessories: page 4.24
MEASURING FUNCTIONS:
Voltage: TRMS, peak, crest factor
(4-channel);
Current: TRMS, peak, crest factor
(4-channel);
Power (active, reactive, apparent);
Power factor, cos ;
Unbalance, icker measurement;
Harmonic analysis up to 50
th
harmon-
ics, THD measurement;
Energy (active, reactive, generated,
consumed);
Capturing and recording of power sup-
ply events (shutdowns, interruptions,
swells, dips);
Inrush currents monitoring and recording;
Waveform displaying and snapshot;
Power quality analysis according to EN
50160;
Recording up to 10 adjustable alarms.
KEY FEATURES:
4 voltage channels with wide meas-
urement range: 0 ... 1000 Vrms (CAT
III / 1000 V).
4 current channels with support for au-
tomatic clamp recognition.
Compliance with power quality stand-
ard IEC 61000-4-30 Class S.
Power measurements compliance with
IEC 61557-12 and IEEE 1448 standards.
Simultaneous measurement and re-
cording of basic power quality param-
eters (U, I, P, Q, S, PF, cos , THD).
Power quality analysis according to EN
50160 including icker measurement
and standardized report printout in
graphic and table form.
4-quadrant measurements (generator
and load with capacitive or inductive
character).
Up to 509 parameters can be moni-
tored or recorded simultaneously.
8 MB of internal memory space allows
recording over 4 weeks.
On-line Scope, Trend and Metering
modes.
MI 2592 PowerQ4
The MI 2592 PowerQ4 is a handheld, simple to use, portable power quality analyser with four current and four voltage
measuring channels. Integrated in rugged housing and packed with powerful functions it can be effectively used for
monitoring, troubleshooting and analysing of power quality conditions in power distribution networks either in industry
or utilities. The PowerQ4 is the first handheld power quality analyser which is compliant with power quality standard
IEC 61000-4-30 Class S and standard IEC 61557-12. Powerful PC Software package PowerView3 comes delivered as part
of a standard set and enables downloading, analysing of recorded data and creation of test reports. Trough a simple but
powerful interface PowerView3 helps to find recorded data quickly and allows to make complex analysis and data com-
parison.
On-screen displaying of trends and
captured events and simultaneous re-
cording in the background.
Flexible clamps (without additional sup-
ply) are included in the standard set.
Simultaneous 8 channels - 16 bit AD
conversion for accurate power meas-
urements (minimal phase shift error)
15 hours of autonomous (battery) supply.
Powerful PC SW PowerView3 ena-
bles downloading, view, analysis of
recorded data and professional report
creation.
APPLICATION:
Power quality assessment and trou-
bleshooting in low and middle voltage
electrical systems;
Checking power correction equipment
performance;
Harmonics spectrum analysis for se-
lection of harmonic lters;
UPS, voltage generators and regula-
tors checking and troubleshooting;
Voltage, current, power monitoring
and recording;
Consumption prole recording.
STANDARDS:
Functionality: IEC/EN 61000-4-30,
Class S; IEC/EN 61557-12; IEC/EN
61000-4-7, Class II; IEC/EN 61000-4-15;
EN 50160; IEEE 1448
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1
STANDARD SET:
MI 2592
Instrument PowerQ4
1-phase exible current clamps 3000 / 300
/ 30 A (A 1227), 4 pcs
Test probe, red, 3 pcs
Test probe, black, green
Crocodile clip, black, green
Crocodile clip, red, 3 pcs
Voltage measurement lead, red, 3 pcs
Voltage measurement lead, black, green
PC SW PowerView3
RS232 and USB cables
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
TECHNICAL SPECIFICATION:
Function
AC Voltage inputs
Number of inputs
Input voltage range
Basic accuracy
Resolution
Sampling rate
Frequency range
4
20 1500 Vrms L - N (20 2600 Vrms L - L)
0.2 % of reading
10 mV, 100 mV
1024 samples per 10 periods
10 70 Hz
AC Current inputs
Number of inputs
Input voltage range
Current measuring range
Resolution
Basic accuracy
Sampling rate
4
20.0 mVrms 2 Vrms
3 6000 A (for current clamp A 1227)
0.1 mV (0.1 A for current clamp A 1227)
0.25 % of reading
1024 samples per 10 periods
Function Measuring range Resolution Accuracy
Frequency 10.00 70.00 Hz 2 mHz 10 mHz
Power (W, VA, VAR) 0.000 k 9.999 M 4 digits 0.5 % of reading
Power factor -1.00 1.00 0.01 0.02
cos 0.00 1.00 0.01 0.02
Harmonics analysis up 50
th
component
UhN < 3 % Unom
3 % Unom < UhN < 20 % Unom
IhN < 10 % IN
10 % IN < IhN < 100 % IN
10 mV
10 mV
10 mV
10 mV
0.15 %Unom
5 %UhN
0.15 %IN
5 %IhN
THD
0 % Unom < THDU < 20 % Unom
0 % IN < THDI < 100 % IN
100 % IN < THDI < 200 % IN
0.1%
0.1%
0.1%
0.3
0.6
1.5
Voltage dips and swells
Magnitude
Duration
20 1500 V
30 ms 7 days
10 mV, 100 mV
1 ms
0.5 % of reading
20 ms
Recording
Integration interval
Maximum number of signals
1 3600 s
509
COM port RS232 and USB
Display Graphic LCD with backlight, 320 x 200 dots
Memory module 8 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
Over voltage category CAT III / 1000 V; CAT IV / 600 V
Protection class Double insulation
Dimensions 220 x 115 x 90 mm
Weight 0.65 kg
Power Quality Analysis Power Quality Analysis
4. 16 4. 17 Accessories: page 4.24 Accessories: page 4.24
MEASURING FUNCTIONS:
TRMS voltage;
TRMS current;
Power (active, reactive, apparent);
Power factor, cos ;
Energy (active, reactive, generated,
consumed);
Power quality analysis according to EN
50160;
Harmonic analysis up to 50
th
harmon-
ics, THD measurement;
Capturing and recording of power sup-
ply events (shut-downs, interruptions,
swells, dips);
Phase diagram and unbalance;
Inrush currents monitoring and record-
ing.
KEY FEATURES:
Three current and three voltage in-
puts.
Measurement and recording of basic
power quality parameters (U, I, P, Q, S,
PF, cos , THD).
Power quality analysis according to EN
50160 including standardized report
printout.
4-quadrant measurements (generator
and load with capacitive or inductive
character).
Quick set-up functions.
On-line scope and metering modes.
Voltage unbalance calculation for 3-
phase systems.
Recording of anomalies and inrush cur-
rents via adjustable triggers.
Lightweight design.
Large LCD display enables on-line
monitoring of measuring results either
in table or graphic form.
PC SW PowerView3 included in the
standard set is used for downloading,
management of recorded data and
creation of test reports.
MI 2392 PowerQ
Plus
The MI 2392 PowerQ
Plus
is a portable multifunction instrument for measurement and analysis of three-phase power sys-
tems. Due to the small dimensions and user friendly interface of the MI 2392 PowerQ
Plus
it is ideally suited for routine or
complex power quality assessment, while a rugged case allows to use it in heavy duty industrial environments. Pre-set
measuring profiles allow on-site evaluation of all major power quality parameters (U, I, P, Q, S, PF, cos , THD, individual
harmonic components, etc.) even without using a PC. Built-in memory module ensures up to five days of recording. New
powerful PC Software package PowerView3 comes delivered as part of a standard set and enables downloading, complex
analysing and comparison of recorded data and creation of test reports.
APPLICATION:
Power quality assessment and trou-
bleshooting in low and middle voltage
electrical systems;
Balancing phase loads in 3-phase sys-
tems;
Checking power correction equipment
performance;
Harmonics spectrum analysis for se-
lection of harmonic lters;
Motors inrush currents monitoring
and recording for in-depth analysis of
a machines start-up or shut-down ef-
fects on a power network;
Voltage uctuation recording;
Consumption recording.
STANDARDS:
Functionality:
EN 50160;
IEC/EN 61000-4-30, Class B
Electromagnetic compatibility:
IEC/EN 61326-1
Safety:
IEC/EN 61010-1
TECHNICAL SPECIFICATION:
Function
AC Voltage inputs
Number of inputs
Input voltage range
Basic accuracy
Resolution
Sampling rate
3
3.0 550.0 Vrms L - N (952.0 Vrms L - L)
(1 % of reading + 0.5 V)
0.1 V
1024 samples per 10 periods
AC Current inputs
Number of inputs
Input voltage range
Current measuring range
Resolution
Basic accuracy
Sampling rate
3
0.04 1 Vrms
4 100 A and 40 1000 A (with current clamp A 1033)
0.1 A
(2 % of reading + 0.3 A)
1024 samples per 10 periods
Function Measuring range Resolution Accuracy
Frequency 45.00 66.00 Hz 10 mHz (0.5 % of reading + 0.02 Hz)
Power (W, VA, VAR)
0.000 0.999 k
0.00 9.99 k
0.0 999.9 k
0.000 9.999 M
0.00 99.99 M
0.0 999.9 M
0.000 9.999 G
0.00 40.00 G
1
10
100
1 k
10 k
100 k
1 M
10 M
(3 % of reading + 3 digits)
Power factor, cos
0.00 0.39
0.40 1.00
0.01
0.01
0.06
0.03
Harmonics analysis up 50
th
component
UM > 3 % UN (IM > 3 % IN)
UM < 3 % UN (IM < 3 % IN)
0.1 %
0.1 %
5 % UM (IM) (3 % for DC)
0.15 % UN (IN)
Recording
Integration period (IP)
Maximum number of signals
1 3600 s
500
COM port RS232 and USB
Display Graphic LCD with backlight, 320 x 200 dots
Memory module 8 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
Overvoltage category CAT IV / 600 V
Protection class Double insulation
Dimensions 220 x 115 x 90 mm
Weight 0.65 kg
STANDARD SET:
MI 2392
Instrument PowerQ
Plus
Current clamp 1000 A / 1 V, 3 pcs
Test probe, red, 3 pcs
Test probe, black
Crocodile clip, black
Crocodile clip, red, 3 pcs
Voltage measurement lead, 4 pcs
PC SW PowerView3 with RS232 and USB
cable
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
MI 2392F
MI 2392
Current clamp 1000 A (A 1033), 3 pcs,
replaced by 1-phase exible current clamp
3000 / 300 / 30 A (A 1227), 3 pcs.
MI 2392F
Power Quality Analysis Power Quality Analysis
4. 18 4. 19 Accessories: page 4.24 Accessories: page 4.24
MEASURING FUNCTIONS:
TRMS voltage;
TRMS current;
Power (active, reactive, apparent);
Power factor, cos ;
Energy (active, reactive, generated,
consumed);
Harmonic analysis up to 50
th
harmon-
ics, THD measurement;
Phase diagram and unbalance;
Oscilloscope mode.
KEY FEATURES:
Three current and three voltage inputs.
Measurement and recording of basic
power quality parameters (U, I, P, Q, S,
PF, cos , THD).
4-quadrant measurements (generator
and load with capacitive or inductive
character).
Harmonics analysis up to 50
th
compo-
nent.
Quick set-up functions.
On-line scope and metering modes.
Voltage unbalance calculation for 3-
phase systems.
Lightweight design.
Large LCD display enables on-line
monitoring of measuring results either
in table or graphic form.
PC SW PowerView3 included in the
standard set is used for downloading,
management of recorded data and
creation of test reports.
APPLICATION:
Power quality assessment and trou-
bleshooting in low and middle voltage
electric systems;
Power correction equipment perfor-
mance testing and designing;
Selection and designing of harmonics
lters;
Monitoring and managing of consump-
tion prole.
MI 2492 PowerQ
The MI 2492 PowerQ is a lightweight, handheld, 3-phase analyser for quick power quality assessment in low and middle
voltage systems. All major power quality parameters like U, I, P, Q, S, PF, cos , THD, individual harmonic components can
be measured, recorded or monitored on-line. Thanks to various pre-set measuring profiles different diagnostics can be
performed on-site even without using a PC. The MI 2492 PowerQ is built into a rugged case which allows to use it in harsh
industrial conditions. Built-in memory module ensures up to five days of recording. New powerful PC Software package
PowerView3 comes delivered as part of a standard set and enables downloading, complex analysing and comparison of
recorded data and creation of test reports.
STANDARDS:
Functionality:
EN 50160;
IEC/EN 61000-4-30, Class B
Electromagnetic compatibility:
IEC/EN 61326-1
Safety:
IEC/EN 61010-1
Function
AC Voltage inputs
Number of inputs
Input voltage range
Basic accuracy
Resolution
Sampling rate
3
3.0 550.0 Vrms L - N (952.0 Vrms L - L)
(1 % of reading + 0.5 V)
0.1 V
1024 samples per 10 periods
AC Current inputs
Number of inputs
Input voltage range
Current measuring range
Resolution
Basic accuracy
Sampling rate
3
0.04 1 Vrms
4 100 A and 40 1000 A (with current clamp A 1033)
0.1 A
(2 % of reading + 0.3 A)
1024 samples per 10 periods
Function Measuring range Resolution Accuracy
Frequency 45.00 66.00 Hz 10 mHz (0.5 % of reading + 0.02 Hz)
Power (W, VA, VAR)
0.000 0.999 k
0.00 9.99 k
0.0 999.9 k
0.000 9.999 M
0.00 99.99 M
0.0 999.9 M
0.000 9.999 G
0.00 40.00 G
1
10
100
1 k
10 k
100 k
1 M
10 M
(3 % of reading + 3 digits)
Power factor, cos
0.00 0.39
0.40 1.00
0.01
0.01
0.06
0.03
Harmonics analysis up 50
th
component
UM > 3 % UN (IM > 3 % IN)
UM < 3 % UN (IM < 3 % IN)
0.1 %
0.1 %
5 % UM (IM) (3 % for DC)
0.15 % UN (IN)
Recording
Integration period (IP)
Maximum number of signals
1 3600 s
500
COM port RS232 and USB
Display Graphic LCD with backlight, 320 x 200 dots
Memory module 8 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
Overvoltage category CAT IV / 600 V
Protection class Double insulation
Dimensions 220 x 115 x 90 mm
Weight 0.65 kg
STANDARD SET:
MI 2492
Instrument PowerQ
Current clamp 1000 A / 1 V, 3 pcs
Test probe, red, 3 pcs
Test probe, black
Crocodile clip, black
Crocodile clip, red, 3 pcs
Voltage measurement lead, 4 pcs
PC SW PowerView3 with RS232 and USB
cable
Power supply adapter
1.2 V NiMH rechargeable battery, 6 pcs
Soft carrying bag
Instruction manual
Calibration certicate
MI 2492F
MI 2492
Current clamp 1000 A (A 1033), 3 pcs, re-
placed by 1-phase exible current clamps
3000 / 300 / 30 A (A 1227), 3 pcs.
TECHNICAL SPECIFICATION:
MI 2492F
Power Quality Analysis Power Quality Analysis
4. 20 4. 21 Accessories: page 4.24 Accessories: page 4.24
MI 2130 VoltScanner
MEASURING FUNCTIONS:
Recording of voltage events (dips,
swells, interruptions);
Recording of frequency variations;
Recording of transient overvoltages;
Power quality analysis according to EN
50160.
KEY FEATURES:
The parameters of the measurement
are set up via PC SW PowerView3.
Recording up to 4 weeks is possible.
Voltage transients down to 1 s can be
captured.
Adjustable triggering limits for voltage
events.
Four LEDs indicates the state of the
instrument (recorded events, low bat-
tery, memory full and incorrect polarity
connection).
PC Software PowerView3 is included
in a standard set and supports down-
loading, data analysis, report creation
and programming of the instrument as
well.
APPLICATION:
Supply voltage testing in accordance
with EN 50160;
Ideal solution for IT managers for con-
trol of input voltage;
Voltage monitoring on the customers
side for power distribution companies.
The MI 2130 VoltScanner is a 1-phase voltage recorder for testing supply voltage on a socket in accordance with EN 50160
power quality standard. Recording up to four weeks is possible and up to 3500 events can be stored into the instruments
memory. The instrument can be easily set up via the PowerView3 software and then sent out to customers who can simply
plug in the instrument for the definite period of time and then send it back for analysis. MS Windows compatible PC Soft-
ware PowerView3 supports programming of the instrument, downloading of recorded data and creation of test reports.
Transfer of recorded data to other MS programs (e.g. Excel, Word, etc.) is possible as well.
TECHNICAL SPECIFICATION:
Measuring function Measuring range Accuracy Resolution
Voltage (swells and dips) 70 265 Vrms (2% of reading + 2 Vrms) 1 Vrms
Transients 50 2600 V (10% of reading + 50 Vrms) 5 Vrms
Frequency 47 62 Hz 0.1 Hz 0.1 Hz
Interruptions < 90 Vrms
1 s (for events up to 3.5 min)
8 s (for longer events)
COM port RS232
Memory module 32 kB
Power supply 4 x 1.2 V NiMH rechargeable batteries, type AA
Over voltage category CAT III / 300 V
Protection Double insulation
Dimensions 103 x 51 x 199 mm
Weight 515 g
STANDARD SET:
MI 2130
Instrument VoltScanner
Mains measuring cable, 1.5 m
1.2 V NiMH rechargeable battery, 4 pcs
PC SW PowerView3
RS232 cable
Instruction manual
Calibration certicate
STANDARDS:
Functionality:
EN 50160
Electromagnetic compatibility:
IEC/EN 61326-1
Safety:
IEC/EN 61010-1
MI 2230 VAFMeter
MEASURING FUNCTIONS:
TRMS Two channel voltage measure-
ments, up to 600 Vac;
TRMS Two channel current measure-
ments, up to 3000 Aac;
U-U, I-I, U-I angle measurement, phase
diagram;
Support for three-phase (Aaron) sys-
tems;
Active, reactive and apparent power,
PF, cos , THD, frequency;
Continuity / resistance of conductors
with 200 mA test current with polarity
change and with pass/fail functional-
ity.
KEY FEATURES:
Simultaneous measurement and dis-
play of voltage, current phase angles
and frequency on two or three-phase
systems.
Accurate phase angle measurement at
low current levels.
Easy to use: large bright LCD display
and large buttons enable easy handling
of the instrument.
Memory storage for storing up to 1500
measurements.
Safe: built for CAT II / 600V environments.
Portable: rugged carrying case with a han-
dle and lightweight design enable easy
moving the instrument between sites.
Built in charger & rechargeable batter-
ies: instrument has a built-in charging
circuit and comes with a set of re-
chargeable NiMH batteries.
Downloadable: downloads test results
via RS232 or USB cable directly to the
PC with the help of the Metrel Eu-
roLink software.
APPLICATION:
VAFMeter instrument is designed to
be used in general electrical systems
maintenance and commissioning, pro-
tective relay testing, electrical machine
repairs or in monitoring power at the
electrical service entrance.
For meter installations, unit measures
phase-to-phase voltage and single-phase
current amplitudes and phase angles.
Combined with a voltage or current
source, instrument also becomes an
excellent tool for testing and calibrating
virtually any type of protective relay.
MI 2230 VAFMeter is handheld multifunction instrument which can accurately measure voltage, current, power, harmonic
distortion and phase angles in single, two and three phase systems.
TECHNICAL SPECIFICATION:
Function Measuring range Basic accuracy
Voltage 6 V ... 600 V (0,5 % of reading + 3 digits
Current
A 1398 - 10 A
A 1395 - 30 A
A 1395 - 300 A
A 1395 - 3000 A
0.1 A ... 20 A
3 A ... 30 A
30 A ... 300 A
300 A ... 3000 A
(1.5 % of reading + 2 digits)
(1.5 % of reading + 2 digits)
(1.5 % of reading + 2 digits)
(1.5 % of reading + 2 digits)
Phase angle -180.0 ... +180.0 0.5
Power
Active
Reactive
Apparent
0.000 W ... 9999 kW
0.000 VAr ... 9999 kVAr
0.000 VA ... 9999 kVA
(1.5 % of reading. + 4 digts)
(1.5 % of reading. + 4 digts)
(1.5 % of reading. + 4 digts)
PF -1.00 ... 1.00 0.04
Cos 0.00 ... 1.00 0.04
THD 0.0 ... 20.0 % 0.5
Resistance
0.0 ... 19.9
20.0 ... 199.9
200 ... 1999
(3 % of reading + 3 digits)
(5 % of reading)
(5 % of reading)
Continuity
0.0 ... 19.9
20 ... 1999
(5 % of reading + 3 digits)
(5 % of reading + 3 digits)
STANDARD SET:
MI 2230
Instrument MI 2230 VAFMeter
Test lead 4 x 1.5 m
Test probe, 4 pcs
A 1395 Flexible current clamps 30/ 300/ 3000 A
STANDARDS:
Functionality:
IEC 61000-4-7;
IEC 61557-12
Electromagnetic compatibility:
IEC 61326-1; IEC 61326-2-2
Safety:
IEC/EN 61010-1
Crocodile clip, 4 pcs
Set of NiMH battery cells
Power supply adapter
Instruction manual
Calibration Certicate
CD with instruction manual, PC SW EuroLink
Set of carrying straps
Power Quality Analysis Power Quality Analysis
4. 22 4. 23 Accessories: page 4.24 Accessories: page 4.24
PowerView3
KEY FEATURES:
User friendly interface: wide range of
quick buttons, possibility to customize
the environment by dragging, docking
and resizing the window tabs.
Structure: downloaded data is organ-
ized into Windows Explorer-like tree
structure.
Drag and drop: downloaded data
can be easily organized into multiple
sites and sub-site locations.
Data ltering: data in a structure can
be grouped by quantity or by phase.
Views: depending on selected record
type, different views are available (Re-
cord Information view, Trend Chart
view, Table view, Waveform Scope
view, Voltage Quality view, etc.)
EN 50160 analysis: automatic volt-
age quality analysis in compliance
with custom or predened EN 50160
Power Quality criteria and quick report
printing.
Chart zoom: chart can be zoomed de-
pending on selected in a table value
range.
Remore control: via GPRS communi-
cation remote handling of the instru-
ment and its data can be executed.
GPS synchronization: simultaneous
measurement on the different net-
work points by using 2 or more syn-
chronized instruments.
PowerView3 software is a powerful platform for downloading, analysing recorded data and creation of power qualty test
reports. PC Software contains a package of functionalities needed for profound evaluation of power quality phenomena,
data comparison and creation of complex test reports. It works in conjunction with Metrel new generation power quality
analysers. For the instruments equipped with GPRS functionality PowerView3 enables remote control of the instrument
as well.
On-line monitoring: when instru-
ment is connected with PC, real-time
observing of signals and parameters is
possible via PowerView3 while instru-
ment is measuring / recording in the
background.
Export of test results: test results can
be exported to other programs (MS Ex-
cel, MS Word).
Reports: automatic generation of test
reports from the selected views and
data with attached graphs.
SW update: PowerView3 checks for new
versions of the application and downloads
updates from the Internet if necessary.
PC SW PowerView3 is compatible with:
MI 2892 PowerMaster
MI 2792A PowerQ4 Plus
MI 2792 PowerQ4 Plus
MI 2592 PowerQ4
MI 2392 PowerQ
PLUS
MI 2492 PowerQ
MI 2130 VoltScanner
Simple interface with tree view organ-
ized data structure and possibility to
customize the environment in numerous
ways by using drag / drop capabilities
PC SOFTWARE
Logged data can be analysed according
to custom or predened EN 50160 Pow-
er Quality criteria
Results can be represented in both trend
and table view simultaneously for easier
analysis
Selected data can be organized into mul-
tiple tabs for easier interpretation
PC SOFTWARE
Power Quality Analysis Power Quality Analysis
4. 24 4. 25 Accessories: page 4.24 Accessories: page 4.24
Option Not available
Selection Guide for PQA Accessories
Photo
Part
number
Description Target application
M
I

2
8
9
2
M
I

2
7
9
2
A
M
I

2
7
9
2
M
I

2
5
9
2
M
I

2
3
9
2
M
I

2
4
9
2
M
I

2
1
3
0
M
I

2
2
3
0
A 1033
Current clamp 1000
A / 1 V
High accuracy current clamp 1000 A / 1 V with jaw opening 52
mm and xed 1.5 m cable for power measurements with Metrel
power quality analysers.

A 1281
Current clamp
0,5/5/100/1000 A / 1 V
Four ranges current clamp for measuring alternating currents
in low and medium power installations. Current clamp is auto-
matically recognized by the instrument. Clamp does not require
external power supply as it is powered by the instrument.

A 1069
Mini current clamp
100 A / 1 V
Mini current clamp 100 A / 1 V with jaw opening 15 mm for
power measurements. Requires A 1039 connection cable.

A 1122
Mini current clamp 5
A / 1 V
Mini current clamp 5 A / 1 V with jaw opening 15 mm for power
measurements. Requires A 1039 connection cable.

A 1039
Connection cable for
current clamp
Connection cable for connecting current clamps A 1069 and A
1122 on Metrel power quality analysers.

A 1179
3-phase exible
current clamp
2000/200/20 A / 1 V
3-phase exible current clamp with three selectable measuring
ranges. Powered by alkaline or rechargeable batteries.

A 1227
1-phase exible
current clamp
3000/300/30 A / 1 V
Single phase exible current clamp with three selectable meas-
uring ranges. Current clamp is automatically recognized by the
instrument. Clamp does not require external power supply as it
is powered by the measuring instrument.

A 1446
1-phase ex-
ible current clamp
6000/600/60 A / 1 V
Single phase exible current clamp with three selectable meas-
uring ranges. Does not require external power supply as it is
powered by the measuring instrument.

A 1257
3-phase exible
current clamp
3000/300/30 A / 1 V
3-phase exible current clamp with three selectable measuring
ranges. Powered by alkaline or rechargeable batteries.

A 1287
1-phase exible
current clamp
3000/300/30 A / 1 V
Single phase exible current clamp with three selectable meas-
uring ranges. Powered by alkaline or rechargeable batteries.

A 1037
Current transformer 5
A / 1 V
3-phase transformer for power measure-ments on distribution
panels with 5 A nominal output current.

A 1355 GPS receiver
GPS Synchronization unit guaranties that the time clock of the Metrel
PowerQ4 Plus analyzer is synchronized according to IEC 61000-4-30.
This performance is necessary to ensure that instruments produce
the same aggregation results when connected to the same signal.

Photo
Part
number
Description Target application
M
I

2
8
9
2
M
I

2
7
9
2
A
M
I

2
7
9
2
M
I

2
5
9
2
M
I

2
3
9
2
M
I

2
4
9
2
M
I

2
1
3
0
M
I

2
2
3
0
A 1356 GPRS modem
GPRS modem data transfer enables remote handling of the meas-
uring instrument and its data. If the measuring instrument has to
be located on distant or hardly accessible place, the GPRS modem
is the only practical solution for fast access to the instrument.

A 1198
Magnetic contact
probe
Test probe with magnetic contact provides reliable contact with
metal surface during the measurement.

A 1014 Test probe, black
Test probe with 4 mm connection is suitable for performing
measurements both in mains outlets and in situations when no
schuko outlet is present.

A 1015 Test probe, blue
Test probe with 4 mm connection is suitable for performing
measurements both in mains outlets and in situations when no
schuko outlet is present.

A 1016 Test probe, red
Test probe with 4 mm connection is suitable for performing
measurements both in mains outlets and in situations when no
schuko outlet is present.

A 1062 Test probe, green
Test probe with 4 mm connection is suitable for performing
measurements both in mains outlets and in situations when no
schuko outlet is present.

A 1013 Crocodile clip, black
Crocodile clip assures secure and permanent contact during the
measurement on bus bars, xing screws, etc.

A 1310 Crocodile clip, blue
Crocodile clip assures secure and permanent contact during the
measurement on bus bars, xing screws, etc.

A 1064 Crocodile clip, red
Crocodile clip assures secure and permanent contact during the
measurement on bus bars, xing screws, etc.

A 1309 Crocodile clip, green
Crocodile clip assures secure and permanent contact during the
measurement on bus bars, xing screws, etc.

A 1011 Test lead, 3 x 1.5 m
3-wire test lead for measurements on single or three phase elec-
trical installations.

S 2014
Safety fuse adapter,
3 pcs
Fuse adapters protect the instrument and the user against cur-
rent strike and overload.

Selection Guide for PQA Accessories
Option Not available
Accessories: page 5.08
Power Quality Analysis
4. 26 Accessories: page 4.24
Photo
Part
number
Description Target application
M
I

2
8
9
2
M
I

2
7
9
2
A
M
I

2
7
9
2
M
I

2
5
9
2
M
I

2
3
9
2
M
I

2
4
9
2
M
I

2
1
3
0
M
I

2
2
3
0
S 2015
Safety at clamp, 4
pcs
Safety at clamps assure good contact when connecting the test
leads on busbars and other larger at surfaces.

A 1017
Communication cable
RS232
RS232 interface cable for connecting the instrument with the
PC.

A 1171
RS232 / USB adapter
with 1 m cable
RS232 / USB adapter for instruments without USB comunica-
tion port.

A 1458
SanDisk microSD card
reader
Move data between your computer and memory card with
memory card reader.

A 1020
Small soft carrying
bag
Small soft carrying bag for transport and storage of test instru-
ment or accessories.

A 1006 Soft carrying bag
Large soft carrying bag for transport and storage of test instru-
ment and belonging accessories.

A 1083
Power supply adapter
with 6 pcs NiMH bat-
teries, type AA
Battery charger and a set of 6 pieces of rechargeable batteries,
type AA.

A 1160
Fast charger for 8 AA
batteries with a set of
6 NiMH bat., type AA
Fast battery charger for up to 8 pieces of AA rechargeable bat-
teries, and a set of 6 pcs NiMH rechargeable batteries, type AA.

A 1169
Fast charger for AA,
C, D and 9 V block
batteries
Fast battery charger for up to 12 pcs AA, 6 pcs C or D recharge-
able batteries, 4 pcs 9 V block batteries.

Selection Guide for PQA Accessories
Option Not available
GOOD TO KNOW
LAN Cabling Certication 5 - 02
Selection Guide for LAN Testers 5 - 03
MI 2016 Multi LAN 350 5 - 04
MI 2014 Cable Scanner 5 - 06
PC SOFTWARE
LAN Link 5 - 07
Selection Guide for LAN Accessories 5 - 08
L
A
N

C
a
b
l
i
n
g

C
e
r
t
i

c
a
t
i
o
n
C
o
m
p
u
t
e
r

N
e
t
w
o
r
k

C
a
b
l
e

T
e
s
t
e
r
s

a
n
d

C
e
r
t
i

e
r
s
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
LAN Cabling Certication
LAN Cabling Certication LAN Cabling Certication
5. 2 5. 3 Accessories: page 5.08 Accessories: page 5.08
Selection Guide for LAN Testers
Part No.:
MI 2016 MI 2014
Multi LAN 350 Cable Scanner
TEST FUNCTIONS
Wiremap
NEXT / Remote NEXT /
PSNEXT / Remote PSNEXT /
ELFEXT / PSELFEXT /
Return Loss / Remote Return Loss /
ACR / Remote ACR /
PSACR / Remote PSACR /
Length
Propagation delay
Delay skew
Impedance
DC resistance
Attenuation
TDR
TDR with TDnext
FEATURES
Frequency range 0 ... 350 MHz
CAT 6
CAT 5 / 5e / /
Coax cable
Internal memory
Cable tracer option
PC Software
RS232 port and cable
USB port and cable
Talk over copper (Talk set)
Cable identiers
RJ 45 output
BNC output
GENERAL DATA
Dimensions 265 x 110 x 185 mm 156 x 100 x 190 mm
Weight 2.1 kg 1 kg
Find out more about LAN installations
testing.
Constant development of IT systems
requires higher data transmission capa-
bilities of computer networks. Accord-
ingly these have to be designed and con-
structed in such a way to meet the latest
requirements which assure long-term
usability and expandability of cooper and
optic bre cabling.
Testing of structured LAN cabling is an
essential part of certication and main-
tenance of LAN networks and assures
that all built-in components comply with
proposed regulation.
Typical termination failures:
Broken or open wire;
Short circuit to shield;
Short circuit between wires;
Crossed, reversed and transposed pairs);
Split pairs;
Other termination problems.
These type of failures can be easily
found with simple test devices called
wire-mapper.
Hidden failures
Proper termination does not necessarily
guarantee proper functioning of cabling
system. Certain failures can only be found
at high data transmission level or higher
operating frequencies. These limit condi-
tions may create signal reections or in-
terferences in adjacent pairs or cables. A
common source of such problems are
installed network components like sock-
ets and plugs that in combination with
built-in termination failures contribute to
data transmission problems.
Such failures can be easily found with
advanced LAN testers that do not only
check wiring but also measure a number
of other electrical parameters in a wide
frequency bandwidth.
Regulations and standards
Specication of LAN certifying testers,
their measuring accuracy, presentation
form of test results and their limit values
have been dened in various standards.
In EU countries it is common that na-
tional legislations refer to the EN 50173,
while globally IEC 11801 is being used
with the TIA 568B specied in the US.
For high capacity LAN networks in class
6 and higher both, Permanent and Chan-
nel link are being tested which urges
for high quality test adapters. Regular
checking of test equipment which may
include calibration is necessary to assure
reliable test results.
Measured parameters:
Wire map
Wire Map test veries the pin to pin wir-
ing and shield continuity.
METRELs hint:
Split pairs cannot be found with simple
continuity checks. They are detected
with a simplied NEXT measurement.
The reason for high crosstalk is not
necessarily a split pair - unsuitable and
careless assembled connectors or cable
faults can also cause a split pair warn-
ing. The real error source can be easily
dened with the TDCross function. The
point of error can be easily found by us-
ing the TDR function. At least one pair
must be connected properly to assure
correct operation of the instrument.
PSNEXT, Remote PSNEXT
PSNEXT (Power Sum Near End Cross-
talk) denes the coupling on one cable
pair from all other pairs. The PSNEXT is
calculated from individual NEXT results
and represents the expected worst case
coupling. Similar to NEXT the coupled
signal from other pairs can cause data
corruption, retransmit ions and other
problems. This is especially critical in
multi-pair data protocols.
NEXT, Remote NEXT
NEXT (near end crosstalk) denes the
coupling between adjacent pairs. High
level signals transmitted in one pair on
a cable end can induce a substantial dis-
turbance signal in the neighboring pairs,
on the same (transmitter) side. This
signal added to the signals transmitted
from the other cable can cause data
corruption, retransmit ions and other
problems. The most common causes
for NEXT problems are poor twisting on
connector points, non matched connec-
tion components, split pairs etc.
ELFEXT, Remote ELFEXT
FEXT (Far End Crosstalk) denes cross-
talk caused by the coupling of a signal
from a pair transmitted on one cable side
into an adjacent pair with the receiver on
the other side.
ELFEXT (Equivalent Level Far End Cross-
talk) is calculated from FEXT and the
attenuation on the receiver pair.
The main result is given as the worst
case margin in dB to the test standard
limit. High ELFEXT causes typical cross-
talk problems: data corruption, retrans-
mitions etc.
PSELFEXT, Remote PSELFEXT
PSFEXT (Power Sum Far End Crosstalk)
denes crosstalk caused by the coupling
of signals into a cable pair from other
pairs. The receiver of crosstalk signals is
on one cable side and the transmitters on
the other cable side on another pair.
PSELFEXT (Power Sum Equivalent Level
Far End Crosstalk) is calculated from
PSFEXT and the attenuation on the re-
ceiver pair.
High PSELFEXTs cause typical crosstalk prob-
lems: data corruption, retransmit ions, etc.
RETURN LOSS, Remote RETURN LOSS
Return loss is the ratio between trans-
mitted and reected signals at the
transmission end. High return loss rates
are often caused by local impedance
mismatching and decrease the signal
strength on the receiver end.
Attenuation
Attenuation is the measured loss of sig-
nal strength in a pair from one cable end
to the other. It increases with frequency
and cable length so it has to be measured
over the complete frequency range. At-
tenuation is one of the main cable pa-
rameters that dramatically inuences the
maximum bit rate of data stream allowed.
PSACR, Remote PSACR
PSACR (Attenuation to crosstalk ratio) is
a comparison of the attenuated regular
signal and disturbing crosstalk signals
from other pairs on the receiver side.
PSACR is computed from Attenuation
and PSNEXT.
PSACR(f) = PSNEXT(f) - Attenuation(f)
PSACR results consider Attenuation
and PSNEXT. It is taken in account that
at shorter cables the PSNEXT could be
higher without degradation of the link
performance. Therefore it is very suita-
LAN Cabling Certication
GOOD TO KNOW GOOD TO KNOW
ble for the estimation whether the cross-
talks are critical or not.
ACR, Remote ACR
ACR (Attenuation to crosstalk ratio) is
a comparison of the attenuated regular
signal and disturbing crosstalk signals
on the receiver side. High ACR values
indicate a high performance connection
where the crosstalk levels are small in
comparison with attenuation. ACR is
computed from Attenuation and NEXT.
ACR(f) = NEXT(f) - Attenuation(f)
The ACR results consider Attenuation
and NEXT. It is taken in account that at
shorter cables the NEXT could be higher
without degradation of the link perfor-
mance. Therefore ACR is very suitable
for the estimation whether the cross-
talks are critical or not.
Length
The length test measures the length of
each cable pair.
The cable length is determined from the
time it takes for a pulse to travel along
the cable. To get the right result the pulse
propagation speed has to be known. The
NVP factors can be set (nominal velocity
propagation factor, given by percents of
light speed) for cables in the Cable Type
Menu. Since they arent exactly dened
from the manufacturer (variations can
occur through ageing, different materi-
als, temperature, number of twists etc)
the length results are only indicative. The
problem intensies at longer lengths.
Delay Skew
Delay skew is the difference in propaga-
tion delays between test pulses through
different cable pairs. The shortest delay
is referenced to 0ns. High delay skews
can cause trouble especially when fast
multi-pair data protocols are used.
Propagation Delay
Propagation delay is the time it takes a
test pulse to travel the length of each
cable pair.
Impedance
Impedance is a characteristic of the
cable. In general the characteristic im-
pedances in high frequency systems
must be matched to ensure a regular
data ow. Every change in impedance
along the link will cause a reection and
decrease the signal strength on the re-
ceiver end. A change in impedance can
occur if using improper cables, cable
components or the cable is damaged.
DC Resistance
DC resistance test veries that the loop
resistances (sum of resistances of both
wires) in individual pairs are within the
given limits.
Additional recommendations
Additional to the measurements de-
ned by standards there are some other
measurements that may help at analys-
ing network conditions and failure nd-
ing. TDR (time domain reecto-meter)
is one of such tools which is frequently
being used to nd a faulty spot along the
LAN cable. Test signal is sent along the
tested cable and based on its reection
strength and reection time a distance
to the faulty spot is calculated.
Another test function TD NEXT meas-
ures a distance with the highest cross-
talk along the tested cable.
LAN Cabling Certication LAN Cabling Certication
5. 4 5. 5 Accessories: page 5.08 Accessories: page 5.08
MEASURING FUNCTIONS:
Cable length;
Propagation delay;
Delay skew;
Characteristic Impedance;
DC resistance;
Attenuation;
NEXT, Remote NEXT;
PSNEXT, Remote PSNEXT;
ELFEXT, Remote ELFEXT;
PSELFEXT;
Return loss, REMOTE Return loss;
ACR, Remote ACR;
PSACR, Remote PSACR;
TDR (Time Domain Reectometer);
Time Domain Crosstalk;
Wire map test.
KEY FEATURES:
Top class CAT 6 / Class E LAN certi-
cation tester for testing high speed
networks with a test frequency up to
350 MHz.
Extensive database of Autotests for
complete and quick LAN cabling veri-
cation in accordance with all leading
test standards.
Instrument supports UTP, STP, ScTP
and FTP cables testing.
Adapters included in the standard set
enables both Channel and Permanent
Link connection.
High resolution TDR with TDnext func-
tions for quick determination of a dis-
tance to a faulty point along the cable.
LAN Link PC software package includ-
ed in the standard set enables analysis
of test data and test report creation.
PASS / FAIL evaluation of test results
according to selected test standard.
Graphical representation of test results
on instruments display.
APPLICATION:
Verication of LAN networks up to CAT
6 / Class E;
Troubleshooting in IT networks.
MI 2016 Multi LAN 350
The MI 2016 Multi LAN 350 is a high quality measuring instrument for LAN cabling verication up to CAT 6 / Class E accord-
ing to international standards EN 50173, TIA/EIA 658B, ISO/IEC 11801, etc. The seamless execution of complete autotest
with Pass / Fail evaluation of results can be performed within 55 seconds. The built-in intercom system allows easy com-
munication through the length of the cabling. The autosequence mode and single test mode (useful in troubleshooting),
large graphical LCD with backlight, help screens and PC software as standard accessory make LAN testing with MI 2016
simple, easy and comprehensive.
Selectable test standards for complet and
quick LAN cabling verication.
KEY FEATURES
TDNext function for determination of faulty
points.
TECHNICAL SPECIFICATION:
MI 2016ST
Instrument Multi LAN 350
Remote unit Multi LAN 350
Permanent Link adapter, 2 pcs
Chanel Link adapter, 2 pcs
Locators (#1 ... #4), 4 pcs
Attenuation calibration module
Power supply adapter, 2 pcs
Headphones set, 2 pcs
Carrying bag, 2 pcs
PC SW LAN Link with USB and RS232
cables
12 x 1.5 V NiMH rechargeable batteries,
type C
Instruction manual
Calibration certicate

MI 2016PS
MI 2016ST
Remote unit Multi LAN 350 is replaced by
Instrument Multi LAN 350
STANDARD SET:
STANDARDS:
Functionality:
TIA/EIA 568B Cat 3, Cat 5, Cat 5 E, Cat 6; ISO 11801; EN 50173
Safety: IEC/EN 611010-1; IEC 60825-1
Function Measuring range Resolution Accuracy
Length
0.0 99.9 m
100 300 m
0.1 m
1 m
(3 % of reading + 5 digits)
4 % of reading
Propagation delay
0 500 ns
501 4000 ns
1 ns
1 ns
(3 % of reading + 5 digits)
3 % of reading
Delay skew 0 500 ns 1 ns 10 digits
Characteristic Impedance 35 180 1 (10 % of reading + 3 digits)
DC Resistance 0.0 199.9 0.1 (10 % of reading + 5 digits)
Attenuation
- Frequency 1 MHz 250 MHz 1 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 60.0 dB 0.1 dB
NEXT, Remote NEXT
- Frequency 1 MHz 350 MHz 0.15 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 90.0 dB 0.1 dB
PSNEXT, Remote PSNEXT
- Frequency 1 MHz 350 MHz 0.15 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 90.0 dB 0.1 dB
ELFEXT, Remote ELFEXT
- Frequency 1 MHz 350 MHz 0.15 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 90.0 dB 0.1 dB
PSELFEXT
- Frequency 1 MHz 350 MHz 0.15 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 70.0 dB 0.1 dB
Return Loss, Remote Return Loss
- Frequency 1 MHz 350 MHz 0.15 MHz According to TIA/EIA 568-B.2
- Amplitude 0.0 40.0 dB 0.1 dB
Time Domain Reectometer (TDR) at NVP=0.69c:
- Distance / Pulse length
0 10 (50, 100) m
0 200 m
0 400 m
1 ns, 0.1 m
2 ns, 0.2 m
4 ns, 0.4 m
(3 % of reading + 5 digits)
5 % of reading
5 % of reading
- Amplitude in percents 1 %
- Selectable propagation velocity rate 0.50 c 0.99 c
Time Domain Crosstalk
- Distance / Pulse length
0 10 (50, 100) m
0 200 m
1 ns, 0.1 m
20 ns, 0.2 m
(3 % of reading + 5 digits)
5 % of reading
- Amplitude in percents 0.1 %
General
COM port RS232 and USB
Display Graphic LCD, 320 x 240 dots, with backlight
Power supply 6 x 1.2 rechargeable batteries, type C
Dimensions 265 x 110 x 185 mm
Weight 2.1 kg
LAN Cabling Certication LAN Cabling Certication
5. 6 5. 7 Accessories: page 5.08 Accessories: page 5.08
MI 2014 Cable Scanner
MEASURING FUNCTIONS:
Cable length;
TDR (Time Domain Reectometer);
Time Domain Crosstalk;
Wire map test.
KEY FEATURES:
Fast termination fault nding with
graphical indication of the failure type.
Integrated high accuracy TDR function
with adjustable NVP factor measures
distance to the fault.
Internal tone generator combined with
an optional Cable tracer serves for
wire nding in bounces of cables.
Locators for simplied identication of
sockets are included in a standard set.
Optional Talk Remote Unit allows voice
communication over the tested cable.
Instruments outputs allow testing on
RJ 45 and coax terminations.
APPLICATION:
Troubleshooting and maintenance of
LAN and other cable networks.
STANDARDS:
Electromagnetic compatibility:
EN 50081-1;
EN 50882-1
Safety:
EN 611010-1
STANDARD SET:
MI 2014
Instrument Cable Scanner
Cat 5 Patch cable, 2 pcs
Standard Remote #1
Locators (#1 ... #4), 4 pcs
Instruction manual
Calibration certicate
The MI 2014 Cable Scanner is a portable handheld battery powered instrument
intended for testing LAN installations and cables. This simple but effective de-
vice performs copper terminations testing on shielded and unshielded LAN and
coax cables. With optional Tracer can be performed tracing of cables and wires.
Talk function enables full duplex communication between remote operators.
Due to user friendly interface handling of the instrument is simple and clear.
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Twisted Pair cable / Length and Reections
- Distance
0.0 99.9 m
100 300 m
0.1 m
1 m
(3% of readings + 5 digits)
(5% of readings + 1 digits)
- Amplitude -99 % 100 % 1 % (5% of readings + 5 digits)
Coax cable / Length and Reections
- Distance
0.0 99.9 m
100 300 m
0.1 m
1 m
(3% of readings + 5 digits)
5% of readings
- Amplitude -99 % 100 % 1 % (5% of readings + 5 digits)
Power supply 6 x 1.5 V alkaline or 6 x 1.2 V rechargeable batteries, type AA
Dimensions 156 x 100 x 190 mm
Weight 1 kg
LAN Link
KEY FEATURES:
User friendly interface: wide range
of quick icons, for downloading, ex-
porting, viewing and reorganizing data.
Downloading Autotest results or
Plots: After connecting the Multi LAN
350 to a PC stored Autotest Results or
memorized Plots can be downloaded.
Structure organized data: download-
ed data are organized into tree struc-
ture where the locations could be
renamed and / or equiped with com-
ments. Separate Object, Floor or Ca-
ble location number could be changed
to any alphanumeric name.
Creating test Reports: automatic
generation of test reports from the
selected views and data with attached
graphs. The Operator/Test site menu
enabeling the operator to create his
own Test Report Header and Footer.
BMP logo can be added.
Comments menu: any text can be
added to the Test Report Header.
Evaluation and printout of three
different levels of Test Reports:
Full Detail Report provides the most
complete information about the per-
formed measurements including Pass/
Fail decision for performed measure-
ments, overall headroom results or
margins for individual pairs.
Medium Detail Report shows Pass/
Fail decision for performed measure-
ments and the overall headroom for
individual cables are displayed.
Low Detail Report enables you to
make a clear and simple Test Report
providing essential information of the
overall Pass/Fail decision and head-
room for individual cables.
The LAN Link software enables enables downloading, analysing of stored data and transfering latest observed cable char-
acteristics for detailed further research on LAN and Telecommunication Cable Installations.
Export of test results: test results
can be exported to other programs
(MS Excel, MS Word).
Viewing Plots: Graphs and plots of
NEXT, ELFEXT, PSNEXT, PSELFEXT,
Attenuation, Return Loss, ACR,
PSACR, TDR and TDnext can be
downloaded, viewed and printed. The
plots contain additional information
about Test Standard and Cable Type,
date & time of measurement etc.
PC SW LAN Link is compatible with:
MI 2016 Multi LAN 300
After connecting the Multi LAN 350 to
a PC stored Autotest Results or memo-
rized Plots can be downloaded.
PC SOFTWARE
Accessories: page 6.14
LAN Cabling Certication
5. 8 Accessories: page 5.08
GOOD TO KNOW
Indoor Environment Quality 6 - 02
Selection Guide for Indoor Environment Quality Analysers 6 - 04
MI 6201 Multinorm 6 - 06
MI 6301 FonS 6 - 08
MI 6401 Poly 6 - 10
PC SOFTWARE
SensorLink 6 - 12
SoundLink 6 - 13
Selection Guide for IEQ Accessories 6 - 14
I
n
d
o
o
r

E
n
v
i
r
o
n
m
e
n
t

Q
u
a
l
i
t
y
E
n
v
i
r
o
n
m
e
n
t
a
l

M
o
n
i
t
o
r
i
n
g

E
q
u
i
p
m
e
n
t

f
o
r

T
e
s
t
i
n
g

t
h
e

C
o
n
d
i
t
i
o
n
s

o
f

I
n
d
o
o
r

E
n
v
i
r
o
n
m
e
n
t
s
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
Selection Guide for LAN Accessories
Photo
Part
number
Description Target application
M
I

2
0
1
6
M
I

2
0
1
4
A 1006 Soft carrying bag
Large soft carrying bag for transport and storage of test instrument and belonging
accessories.

A 1007 Carrying strap
Carrying strap for carrying the measuring instrument around the neck allowing free
hand use of the tester.

A 1041
Headphones with
microphone, 2 pcs
Talk set with two earphones allows communication over the tested communication
cable.

A 1043
Locator set II (#5 to
#16)
Locators simplify and accelerate nummerication and identication of LAN sockets.
Set includes locators with number from #5 up to #16.

A 1044
Locator set III (#17
to #28)
Locators simplify and accelerate nummerication and identication of LAN sockets.
Transponders with numbers from #17 up to #28 are delivered with the set.

A 1046
1.2 V NiMH battery,
type C, 6 pcs
A set of 6 pieces of rechargeable batteries, type C.
A 1082 Cable tracer
Cable tracer is intended for wire tracing on dead or live low voltage installations. To
be used with MI 2014.

A 1083
Power supply adapter
with 6 pcs NiMH bat-
teries, type AA
Battery charger and a set of 6 pieces of rechargeable batteries, type AA.
A 1169
Fast charger for AA,
C, D and 9 V block
batteries
Fast battery charger for up to 12 pcs AA, 6 pcs C or D rechargeable batteries, 4 pcs
9 V block batteries.

S 2004
Talk remote unit with
headphones set
Talk set includes Talk remote unit and two earphones and enables communication
over the tested computer or phone line. To be used with MI 2014.

S 2005
Standard remote set
(#2 ... #6)
Standard remote set contains a package of locators with numbers from #2 up to #6 for
detailed measurements on communication connections and identication of sockets.
To be used with MI 2014.

S 2006
Standard remote set
(#7 ... #15)
Standard remote set contains a package of locators with numbers from #7 up to #15
for detailed measurements on communication connections and identication of sock-
ets. To be used with MI 2014.

Option Not available
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
Indoor Environment Quality
Indoor Environment Quality Indoor Environment Quality
6. 2 6. 3 Accessories: page 6.14 Accessories: page 6.14
Indoor Environment Quality Indoor Environment Quality
GOOD TO KNOW GOOD TO KNOW
Find out more about Indoor Environ-
ment Quality parameters testing
Indoor Environmental Quality (IEQ) en-
compasses all aspects of the indoor
setting including air quality, ventilation,
thermal comfort, lighting and noise.
Indoor air quality (IAQ) refers to the
quality of the air inside buildings as rep-
resented by concentrations of pollut-
ants and the thermal (temperature and
relative humidity) conditions that affect
the health, comfort, and performance
of occupants. Other factors affecting
occupants, such as light and noise, are
important indoor environmental quality
considerations.
Poor indoor air quality can lead to a
number of physical symptoms and
complaints like headaches, fatigue,
shortness of breath, sinus congestion,
coughs, sneezing, eye, nose, and throat
irritation, skin irritation, dizziness, nau-
sea, etc.
A healthy and comfortable indoor envi-
ronment relies on a correct combination
of temperature, humidity, air movement
and task lighting.
Measurements that can be performed
with Metrel IEQ instruments:
Air Temperature (C)
Thermocouple Temperature (C)
Temperature Difference (C)
Relative Humidity (%)
Dew Point (C)
Natural Wet Bulb Temp. (C)
Black Globe Radiant Temperature (C)
WBGT Index (C)
Air Velocity (m/s)
Air Flow (m
3
/h)
PMV Index
PPD Index (%)
Illuminance (Lux)
Luminance (cd/m
2
)
Contrast
CO Concentration (ppm)
CO
2
Concentration (ppm)
Sound level (dB)
1/1 Octave Analysis
1/3 Octave Analysis
IAQ parameters
Air Temperature (C)
Temperature is the degree of hotness or
coldness of a body or environment.
Thermocouple Temperature (C), Tem-
perature Difference (C)
Thermocouple is a device for accurate
wide range measurement of tempera-
ture. It consists of two wires of different
metals joined at each end. One junction
is placed where the temperature is to
be measured, and the other is kept at a
constant lower (reference) temperature.
Since voltage changes in proportion to
temperature (41 V/C), the measured
voltage difference indicates temperature
differences.
If the thermocouple probe is connected
to the instrument the temperature differ-
ence between measured thermocouple
temperature and air temperature is cal-
culated:
T=TC -T
T - temperature difference;
TC - thermocouple temperature;
T - air temperature.
Relative Humidity (%)
Relative humidity is a term used to de-
scribe the ratio of the amount of water
vapor in the air at a specic temperature
to the maximum amount that the air
could hold at that temperature.
The two most common electronic sen-
sors are used to measure humidity:
capacitive or resistive. The capacitive
sensors sense water by applying an AC
signal between two plates and measur-
ing the change in capacitance caused by
the amount of water present.
Dew Point (C)
The dew point is the temperature at
which air becomes saturated when
cooled without addition of moisture or
change of pressure. Any further cooling
causes condensation, fog and dew are
formed in this way.
Dew point is calculated from air tem-
perature and relative humidity, so for
accurate measurement the longer ex-
position time of air temperature or rela-
tive humidity measurements should be
considered.
Natural Wet Bulb Temperature (C)
Natural Wet Bulb temperature is indi-
cated by a moistened thermometer bulb
exposed to the air ow.
Wet bulb temperature can be calculated
or measured using a thermometer with
the bulb wrapped in wet muslin. A wet
bulb thermometer measures the extent
of cooling as moisture dries from a sur-
face (evaporative cooling). The wet bulb
temperature is always lower than the
dry bulb temperature except when there
is 100% relative humidity.
Black Globe Radiant Temperature (C)
Black Globe Radiant Temperature is
amount of heat accepted by the body
due to the radiation of either direct light
or hot objects in the environment.
For instance, if the sun is setting, turn-
ing to night, you may feel a coolness,
although the temperature is unchanged
at that moment.
WBGT Index (C)
WBGT (Wet Bulb Globe Temperature) in-
dex is composite temperature used to es-
timate the effect of temperature, humidity,
and solar radiation on humans. It is used
by industrial hygienists, athletes, and the
military to determine appropriate exposure
levels to high temperatures.
The WBGT index is the most widely used
heat stress index and is standardized in
ISO 7243. Metrel instruments supports
automatic indoor WBGT index calculation:
WBGT (indoor) = 0.7 * TWB + 0.3 * TG
TWB Natural wet bulb temperature;
TG Black globe temperature.
Air Velocity (m/s)
Velocity is distance travelled per unit of
time, usually it is expressed in meter per
second (m/s). Air Velocity is measured
with hot wire anemometer.
Air Flow (m
3
/h)
By multiplying air velocity by the cross
section area of a duct, the air volume
owing past a point in the duct per unit
of time can be determined; unit is usu-
ally cubic meter per hour (m
3
/h).
PMV Index
PMV (Predicted Mean Vote) is an index,
which predicts the mean value of the
votes of a large group of persons. PMV
index is calculated automatically by Me-
trel instruments from the inputs of air
temperature, mean radiant temperature,
relative humidity, air velocity, clothing
thermal resistance and metabolic rate.
The PMV index should be in the bounda-
ries from 0.7 to 0.7 for acceptable ther-
mal environment in indoor places.
PMV value Thermal sensation scale
3 to 2 hot
2 to 1 warm
1 to 0.7 slightly warm
0.7 to 0.7 neutral
-0.7 to -1 slightly cold
-1 to -2 cool
-2 to -3 cold
PMV values
PPD Index (%)
PPD (Predicted Percentage of Dissatis-
ed) is an index that predicts the number
of thermally dissatised persons among
a large group of people.
The PPD index should be less than 15
% for acceptable thermal environment
in indoor places.
The PPD index is automatically shown
by Metrel instruments.
Illuminance (Lux)
Illuminance is a term expressing the
density of luminous ux incident on a
surface:
E = dF / dA,
where A is the area of the illuminated
surface and F is the luminous ux.

Common levels of Illuminance in various
conditions:
Lumens per Square Meter (lm/m
2
or lux)
Sunlight alone (maximum) 102.000
Television stage 25.000
Skylight alone (maximum) 16.000
Dull day 1.000
Merchandise display indoors 1.000
Recommended for reading 500
Public areas in buildings 300
Moonlight 0.4
Starlight 0.002
Luminance (cd/m
2
)
Luminance is the amount of visible light
leaving a point on a surface in a given
direction, the unit of measurement is
candelas per square meter (cd/m
2
).
Luminance indicates how much lumi-
nous power will be perceived by an eye
looking at the surface from a particular
angle of view.
Luminance probe measures luminance
of different surfaces. The silicon photo-
cell measures light received by the lens;
acceptance angle is 3.5.
Diameters of measuring area for differ-
ent probe-surface distances:
Probe to surface distance (m) Diameter of measuring area (mm)
0.75 46
1 61
2 122
3 185
4 245
5 305
6 365
7 430
Contrast
Contrast is difference in the color and
brightness of the object and other ob-
jects within the same eld of view.
CO Concentration (ppm)
Carbon monoxide is one of the most
acutely toxic indoor air contaminants,
it is colourless, odourless, tasteless,
highly poisonous gas. CO is a by-prod-
uct of incomplete combustion of fos-
sil fuels. Common sources of carbon
monoxide are tobacco smoke, space
heaters using fossil fuels, defective
central heating furnaces and automo-
bile exhaust. By depriving the brain of
oxygen, high levels of carbon monox-
ide can lead to nausea, unconscious-
ness and death.
CO acceptable levels:
Averaging
Times
Maximum
Desirable
Level
Maximum
Acceptable
Level
Maximum
Tolerable
Level
1 hour 13 ppm 30 ppm n/a
8 hours 5 ppm 13 ppm 17,4 ppm
CO
2
Concentration (ppm)
Carbon dioxide is a colourless, odour-
less, tasteless, incombustible and non-
toxic gas, about 1.5 times as heavy
as air, which is indoor mainly produced
by humans. It becomes toxic in higher
concentrations. 1% (10,000 ppm) con-
centration will make some people feel
drowsy, concentrations of 7% to 10%
cause dizziness, headache, visual and
hearing dysfunction, and unconscious-
ness within a few minutes to an hour.
Recommended level is not more than
about 700 ppm over outdoor ambient
(1,000 ppm equals 0.1%).
Sound parameters
Sound is a disturbance of mechanical
energy that propagates through matter
as a wave. Sound is characterized by the
properties of sound waves, which are
frequency, wavelength, period, ampli-
tude and velocity or speed.
Sound pressure is the pressure deviation
from the local ambient pressure caused
by a sound wave.
As the human ear can detect sounds
with a very wide range of amplitudes,
sound pressure is often measured as
a sound level on a logarithmic decibel
scale (dB).
Sound level (dB)
Since the human ear does not have a
at spectral response, sound levels are
often frequency weighted so that the
measured level will match perceived
levels more closely.
A-weighting attempts to match the
response of the human ear to noise
Label is dB(A).
C-weighting is used to measure peak
levels.
10 100 1000 10K
-50
-40
-30
-20
-10
0
10
20
30
40
(D)
(D)
(B)
(A)
100K
Not defined
(B, C)
Indoor Environment Quality Indoor Environment Quality
6. 4 6. 5 Accessories: page 6.14 Accessories: page 6.14
Selection Guide for Indoor Environment Quality Analysers
Part No.:
MI 6201PR MI 6201EU MI 6201ST MI 6301PR MI 6301EU MI 6401EU MI 6401ST
Multinorm FonS Poly
MEASUREMENTS
Air Velocity
Air Flow
Relative Humidity
Dew point
Air teperature
Temperature difference Option Option Option Option Option
K Thermocouple temperature Option Option Option Option Option
Illuminance
Luminance Option Option Option Option Option
Contrast Option Option Option Option Option
Black globe radiant temperature Option Option Option Option Option
CO concentration Option Option Option Option Option
CO2 concentration Option Option Option Option Option
Sound level, class 1 (IEC 1672)
Sound level, class 2 (IEC 1672)
Real time 1/1 octave analysis
Real time 1/3 octave analysis
TEST PROBES
A 1091 Microclimatic probe
A 1127 Humidity and temperature probe Option Option Option Option Option
A 1092 Illuminance probe, type B
A 1132 Luminance probe Option Option Option Option Option
A 1128 Thermocouple probe, type K Option Option Option Option Option
A 1146 Sound probe, class 1
A 1151 Sound probe, class 2
A 1131 Black globe thermometer Option Option Option Option Option
A 1180 CO
2
probe Option Option Option Option Option
A 1181 CO probe Option Option Option Option Option
PC SOFTWARE
A 1134 SensorLink PRO
A 1167 SoundLink LITE
A 1162 SoundLink PRO Option Option Option Option Option
CERTIFICATES
ISO calibration certicate for complete
system

Calibration certicate
1/1 and 1/3 Octave Analysis
Octave is an interval between two
sounds having a ratio of two to one in
terms of their frequency span. For ex-
ample, 200 Hz is an octave higher than
100 Hz; 400 Hz is one octave higher than
200 Hz.
Octave bands are classied according to
their geometric centre frequency based
on the internationally standardized 1000
starting point. The 1000 Hz or 1 kHz band
has limits of about 707 and 1414 Hz.
Frequency analysis mode (1/1 and/or 1/3
octave analysis) is usually used if there is
a need to improve acoustic properties of
a room or working place. The results of
frequency analysis show in which part of
the acoustic spectrum noise originates,
and which frequency components
should thus be attenuated.
1/1 Octave Analysis
Frequency bar graph with 9 bars repre-
senting nine octave bands from 31 Hz
Indoor Environment Quality
GOOD TO KNOW
to 8000 Hz and broadband bar graph for
broadband measurements:
31-62-125-250-500-1000-2000-4000-8000.
1/3 Octave Analysis
Frequency bar graph with 27 bars repre-
senting 27 one-third octave bands from
25 Hz to 10000 Hz and broadband bar
graph for broadband measurement:
25-31-40-50-62-80-100-125-160-200-
250-315-400-500-630-800-1000-1250-
1600-2000-2500-3150-4000-5000-6300-
8000-10000
Class 1 / Class 2
Sound measuring instruments, processors
and probes are classied as being Class 1
or Class 2 according to the measurement
accuracy achieved. A class 1 instrument
may only be formed by combining a class
1 probe with a class 1 processor. Class 1
processor shall, at least, cover the range
from 45 Hz to 7.1 kHz in one third octave
bands. Class 2 processor shall, at least,
cover the same range, or 45 Hz to 5,6 kHz
in octave bands, as specied in ISO 9614.
Indoor Environment Quality Indoor Environment Quality
6. 6 6. 7 Accessories: page 6.14 Accessories: page 6.14
MI 6201 Multinorm
MEASUREMENTS:
Air temperature;
Air velocity;
Air ow;
Relative humidity;
Dew point;
Temperature difference (option);
K thermocouple temperature (option);
Illuminance;
Luminance (option);
Contrast (option);
Black globe radiant temperature (option);
CO and CO2 concentration (option);
Sound level;
Real time 1/1 and 1/3 octave analysis.
KEY FEATURES:
Adaptable: MI 6201 Multinorm can be
used as either a sound meter or envi-
ronmental meter to reduce the amount
of measuring equipment to move be-
tween locations.
Environmental: using various stand-
ard and optional probes, the MI 6201
can be adapted to measure and calcu-
late a combination of up to 16 different
environment parameters (maximum
11 at the same time).
Sound: the instrument can simultane-
ously measure and calculate 19 dif-
ferent sound parameters (displaying
maximum 6 at the same time).
Long lasting: record up to 160 days
worth of data.
Accommodating: due to optional pro-
longation cable or telescopic rod meas-
urements in hard-to-rich spots are
possible, while mounting on a tripod
enables long-lasting recording.
Versatile: can be used for spot checking
of different locations or performing long
investigations in a specific location.
Easy to use: plug in the suitable probes
and the device will automatically adjust
for appropriate measurements.
PPD and PMV calculations: predicted
Percentage of Dissatisfied People (PPD)
and Predicted Mean Vote (PMV) calcula-
tions are performed automatically.
Weighting: A, C, Z frequeny weight-
ings and fast, slow and impulse time
weightings.
Octave frequency analysis: instru-
ment performs real time octave and
one third octave frequency analysis in
accordance with EN 61260 standard.
Logger: logging memory module al-
lows to save up to 4000 measurements
with adjustable integration period.
Downloadable: up to 4000 test results
can be stored in a two level memory
structure and then downloaded to the
PC with the help of the PC software.
APPLICATION:
Indoor air quality testing;
Testing of factory climatic conditions;
The MI 6201 Multinorm is a portable multifunctional handheld instrument for measuring microclimate, sound and light
parameters and it is an invaluable tool for the monitoring and evaluation of indoor environmental conditions according
to national and European standards. Specially designed housing enables connection of a few probes at the same time for
testing of several parameters simultaneously. A large selection of measuring probes allows to measure variety of differ-
ent environmental conditions. The SensorLink PRO and SoundLink LITE software come as standard accessories and enable
downloading data stored in the memory, plotting and printing test results in table and graphic form, on-screen graph
plotting for straightforward data comparison and export of data in text le format. The MI 6201EU set comes complete
with full ISO accredited calibration certicate while the MI 6201PS set comes complete with ISO calibration certicate and
an upgraded sound probe (class 1).
Testing of heating, ventilation and air
conditioning systems;
Testing of lighting conditions;
Emergency lighting systems testing;
Indoor or dry outdoor sound level
measurement;
Industrial sound measurement;
Band-pass and acoustic lter testing;
Acoustic equipment testing.
STANDARDS:
Functionality:
DIN 5032 P1; DIN 5032 P2; DIN 5032
P3; DIN 5032 P4; DIN 5032 P6; DIN
5032 P7; EN 60751; EN 60584-1; EN
12599; EN ISO 7726; ISO 10526; ISO
10527
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1
TECHNICAL SPECIFICATION: TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Microclimatic probe A 1091
- Air temperature -20 C +60 C 0.1 C
0.2 C at 25C
0.5 C over working range
- Relative humidity
0 %RH 10 %RH
10 %RH 90 %RH
90 %RH 100 %RH
0.1 %RH
0.1 %RH
0.1 %RH
3 %RH
2 %RH
3 %RH
- Air velocity
0.10 m/s 9.99 m/s
10.0 m/s 20.0 m/s
0.01 m/s
0.1 m/s
(0.05 m/s + 5 % of reading)
(5 % of reading)
Temperature and humidity probe A 1127
- Air temperature -20 C +60 C 0.1 C 0.5 C
- Relative humidity 0 %RH 100 %RH 0.1 %RH 3 %RH
Black Globe temperature (A 1131)
10.0 C 49.9 C
50.0 C 84.9 C
85.0 C 120.0 C
0.1 C
0.1 C
0.1 C
0.5 C
1.0 C
1.5 C
Illuminance (A 1092; DIN 5032, Class B)
0.01 Lux 19.99 Lux
20.0 Lux 199.9 Lux
200 Lux 1999 Lux
2000 Lux 20000 Lux
0.01 Lux
0.1 Lux
1 Lux
10 Lux
(0.02 Lux +8 % of reading)
(8 % of reading)
(8 % of reading)
(8 % of reading)
Luminance (A 1132; DIN 5032, Class B)
0.1 cd/m
2
39.9 cd/m
2
40 cd/m
2
399 cd/m
2
400 cd/m
2
3999 cd/m
2
4000 cd/m
2
40000 cd/m
2
0.1 cd/m
2
1 cd/m
2
1 cd/m
2
1 cd/m
2
(0.2 cd/m
2
+ 8% of reading)
(8 % of reading)
(8 % of reading)
(8 % of reading)
CO
2
concentration (A 1180) 0 ppm 5000 ppm 1 ppm (3 % of reading + 40 ppm)
CO concentration (A 1181) 0 ppm 500 ppm 1 ppm (5 % of reading + 5 ppm)
Sound level (A 1146) 30 dB 140 dB 0.1 dB Corresponds to EN 61672 Class 1
Sound level (A 1151) 30 dB 140 dB 0.1 dB Corresponds to EN 61672 Class 2
Sound probes A 1146 and A 1151
- Dynamic range: 80 dB
- Frequency weighting: A,C, Zero
- Time weighting: fast, slow, impulse
COM port USB
Memory up to 4000 values
Display Graphical LCD with backlight, 160 x 160 dots
Power supply 6 x 1.2 V rechargeable batteries, type AA
Protection degree IP 40
Dimensions 110 x 85 x 220 mm
Weight 0.56 kg
MI 6201ST
Instrument Multinorm
Carrying case
Probe adapter
Microclimatic probe
Illumination probe, type B
Sound probe, class 2, with foam wind-
screen
Plastic shield for microphone
Tripod adapter
USB cable
Power supply adapter
6 x NiMH rechargeable batteries, type AA
PC SW SensorLink PRO
PC SW SoundLink LITE
Instruction manual
Calibration certicate
MI 6201EU
MI 6201ST
ISO calibration certicate for complete
system
MI 6201PS
MI 6201EU
Sound probe, class 1 (A 1146) instead of
Sound probe, class 2 (A 1151)
STANDARD SET:
Indoor Environment Quality Indoor Environment Quality
6. 8 6. 9 Accessories: page 6.14 Accessories: page 6.14
Sample of on-line reading data analysis with
SoundLink PRO PC software.
KEY FEATURES
Logged data analysis with SoundLink PRO
PC software.
MI 6301 FonS
MEASUREMENTS:
LXY (Time weighted sound level);
LXeq (Time average sound level);
LXYmax (Maximum time weighted
sound level);
LXYmin (Minimum time weighted
sound level);
LXpeak (Peak sound level);
LXE (Sound exposure level);
Percentile sound pressure level;
Real time 1/1 octave analysis;
Real time 1/3 octave analysis.
KEY FEATURES:
Adaptable: the instrument can simul-
taneously measure and calculate 19
different sound parameters (displaying
maximum 6 at the same time).
Weighting: A, C, Z frequeny weight-
ings and fast, slow and impulse time
weightings in accordance with EN
61672 standard.
Dual measuring: two independent
sound measuring channels that can
be set to different time and weighting
settings.
Octave frequency analysis: instru-
ment performs real time octave and
one third octave frequency analysis in
accordance with EN 61260 standard.
Long lasting: record up to 80 days
worth of data.
Versatile: can be used for spot check-
ing of different locations or performing
long investigations in a specific loca-
tion.
One stop readings: according to cus-
tom configuration instrument can dis-
play MAX, MIN, peak readings, equal-
ised readings, channel 1 and channel
2 readings.
Logger: logging memory module al-
lows to save up to 2000 measurements
with adjustable integration period.
Downloadable: up to 2000 test results
can be stored in the two level memory
structure and then downloaded to the
PC with the help of the PC software.
The MI 6301 FonS is a professional sound analyser for sound measurements in accordance with EN 61672 standard Class
1 or Class 2. The MI 6301 contains usual A, C and Z frequeny weightings and fast, slow and impulse time weightings and
in addition the instrument has 2 independent measuring channels which can be set to different weightings. The MI 6301
FonS is ideal for spot checking different locations or performing long term analysis of an area. The PC software SoundLink
LITE included in the standard set enables downloading, review, export and printing of test results while the optional PC
SW SoundLink PRO enables full data analysis, charting and report generation.
APPLICATION:
Indoor or dry outdoor sound level
measurement;
Industrial sound measurement;
Acoustic equipment testing;
Band-pass and acoustic lter testing.
STANDARDS:
Functionality:
EN 61672; EN 61260
Electromagnetic compatibility:
EN 61326
Safety: EN 61010-1
Sound measurement, 1/1 and 1/3 octavian analisys. Recalling of memory, sample of help menu.
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Sound level (A 1146) 30 dB 140 dB 0.1 dB Corresponds to EN 61672 Class 1
Sound level (A 1151) 30 dB 140 dB 0.1 dB Corresponds to EN 61672 Class 2
Sound probes A 1146 and A 1151
- Dynamic range: 80 dB
- Frequency weighting: A,C, Zero
- Time weighting: fast, slow, impulse
COM port USB
Memory 2000 values
Display Graphical LCD with backlight, 160 x 160 dots
Power supply 6 x 1.2 V rechargeable batteries, type AA
Protection degree IP 40
Dimensions 110 x 85 x 220 mm
Weight 0.56 kg
MI 6301EU
Instrument FonS
Carrying case
Sound probe, class 2, with foam wind-
screen
Plastic shield for microphone
Tripod adapter
USB cable
Power supply adapter
6 x NiMH rechargeable batteries, type AA
PC SW SoundLink LITE
Instruction manual
Calibration certicate
ISO calibration certicate for complete
system
MI 6301PS
MI 6301EU
Sound probe, class 1 (A 1146) instead of
Sound probe, class 2 (A 1151)
STANDARD SET:
KEY FEATURES
PTB Approved
Indoor Environment Quality Indoor Environment Quality
6. 10 6. 11 Accessories: page 6.14 Accessories: page 6.14
MI 6401 Poly
MEASUREMENTS:
Air temperature;
Air velocity;
Air ow;
Relative humidity;
Dew point;
Temperature difference (option);
K thermocouple temperature (option);
Illuminance;
Luminance (option);
Contrast (option);
Black globe radiant temperature
(option);
CO and CO2 concentration (option).
KEY FEATURES:
Adaptable: using various standard
and optional probes, the MI 6401 can
be adapted to measure and calculate a
combination of up to 16 different envi-
ronments conditions (maximum 11 at
the same time).
Long lasting: record up to 160 days
worth of data.
Accommodating: due to optional pro-
longation cable or telescopic rod meas-
urements in hard-to-rich spots are
possible, while mounting on a tripod
enables long-lasting recording.
Versatile: can be used for spot check-
ing of different locations or performing
long investigations in a specific loca-
tion.
Easy to use: plug in the suitable probes
and the device will automatically adjust
for appropriate measurements.
PPD and PMV calculations: predicted
Percentage of Dissatisfied People
(PPD) and Predicted Mean Vote (PMV)
calculations are performed automati-
cally.
Logger: logging memory module al-
lows to save up to 4000 measurements
with adjustable integration period.
Downloadable: up to 4000 test results
can be stored in a two level memory
structure and then downloaded to the
PC with the help of the PC software
SensorLink PRO.
APPLICATION:
Indoor air quality testing;
Testing of factory climatic conditions;
Testing of heating, ventilation and air
conditioning systems;
Testing of lighting conditions;
Emergency lighting systems testing.
The MI 6401 Poly is a portable multifunctional handheld instrument for measuring microclimate and light parameters such
as Illuminance, humidity, air temperature and air velocity of an environment. Emergency lighting, ventilation systems,
lighting conditions, air conditioning systems, factory conditions, production line conditions and many more can be tested
by the MI 6401. Specially designed housing enables connection of a few probes at the same time for testing of several
parameters simultaneously. All the results can be stored in the internal memory of the instrument and then downloaded
to PC via the SensorLink PRO software which is included in the standard set. For full data traceability to international
standards the MI 6401EU set includes a full ISO accredited calibration certicate.
STANDARDS:
Functionality:
DIN 5032 P1; DIN 5032 P2; DIN 5032
P3; DIN 5032 P4; DIN 5032 P6;
DIN 5032 P7; EN 60751; EN 60584-1;
EN 12599; EN ISO 7726; ISO 10526;
ISO 10527
Electromagnetic compatibility:
EN 61326
Safety:
EN 61010-1
TECHNICAL SPECIFICATION:
Function Measuring range Resolution Accuracy
Microclimatic probe A 1091
- Air temperature -20 C +60 C 0.1 C
0.2 C at 25C
0.5 C over working range
- Relative humidity
0 %RH 10 %RH
10 %RH 90 %RH
90 %RH 100 %RH
0.1 %RH
0.1 %RH
0.1 %RH
3 %RH
2 %RH
3 %RH
- Air velocity
0.10 m/s 9.99 m/s
10.0 m/s 20.0 m/s
0.01m/s
0.1m/s
(0.05 m/s + 5% of reading)
(5% of reading)
Temperature and humidity probe A 1127
- Air temperature -20 C +60 C 0.1 C 0.5 C
- Relative humidity 0 %RH 100 %RH 0.1 %RH 3 %RH
Black Globe temperature (A 1131)
10.0 C 49.9 C
50.0 C 84.9 C
85.0 C 120.0 C
0.1 C
0.1 C
0.1 C
0.5 C
1.0 C
1.5 C
Illuminance (A 1092; DIN 5032, Class B)
0.01 Lux 19.99 Lux
20.0 Lux 199.9 Lux
200 Lux 1999 Lux
2000 Lux 20000 Lux
0.01 Lux
0.1 Lux
1 Lux
10 Lux
(0.02 Lux +8 % of reading)
(8 % of reading)
(8 % of reading)
(8 % of reading)
Luminance (A 1132; DIN 5032, Class B)
0.1 cd/m
2
39.9 cd/m
2
40 cd/m
2
399 cd/m
2
400 cd/m
2
3999 cd/m
2
4000 cd/m
2
40000 cd/m
2
0.1 cd/m
2
1 cd/m
2
1 cd/m
2
1 cd/m
2
(0.2 cd/m
2
+ 8 % of reading)
(8 % of reading)
(8 % of reading)
(8 % of reading)
CO
2
concentration (A 1180) 0 ppm 5000 ppm 1 ppm (3 % of reading + 40 ppm)
CO concentration (A 1181) 0 ppm 500 ppm 1 ppm (5 % of reading + 5 ppm)
COM port USB
Memory 4000 values
Display Graphical LCD with backlight, 160 x 160 dots
Power supply 6 x 1.2 V rechargeable batteries, type AA
Protection degree IP 40
Dimensions 110 x 85 x 220 mm
Weight 0.56 kg
MI 6401ST
Instrument Poly
Carrying case
Probe adapter
Microclimatic probe
Illumination probe, type B
Tripod adapter
USB cable
Power supply adapter
6 x NiMH rechargeable batteries, type AA
PC SW SensorLink PRO
Instruction manual
Calibration certicate
MI 6401EU
MI 6401ST
ISO calibration certicate for complete
system
STANDARD SET:
Indoor Environment Quality Indoor Environment Quality
6. 12 6. 13 Accessories: page 6.14 Accessories: page 6.14
SensorLink SoundLink
KEY FEATURES:
Automatic recognition of the instru-
ment: connected instrument to the PC is
automatically recognized by the software.
Logger, Memory, Download: Stored
and downloaded data from the instru-
ment could be organized, selected to
group, viewed and compared for ana-
lyzing in graphs and tabelaric forms
and printed in a report form.
Export of test results: test results in
text format can be exported to other
programs (MS Excel, MS Word).
Test Reports: automatic generation of
test reports from the selected views
and data with attached graphs.
PC SW SensorLink is compatible with:
MI 6201 Multinorm
MI 6401 Poly
KEY FEATURES:
User friendly interface: wide range of
quick icons, for downloading, export-
ing, viewing and reorganizing data.
Structure organized data: download-
ed data are organized into tree struc-
ture where the locations could be
renamed and / or equiped with com-
ments.
Data ltering and combining logger
measurements as a function of time.
Zoom in Logger window: Drag it and
zoom rectangle will be drawn.
Spectrum window: graph area and
values area will show Octave and 1/3
Octave bars for analysis where select-
ed logger or single 1/3 result shows
four broadband values and 27 spectral
components of the signal. Broadband
values are shown as blue bars and
every spectral component is shown
as one bar with three different colours
(each one for minimum, average and
maximum).
Results window: shows in tabular
form values of measurements added
from Tree window. Location name,
start and end time and selected meas-
urements are displayed in each line of
table.
The SensorLink software works in conjunction with Metrel downloadable Indoor Environment Quality testers. The soft-
ware automatically recognizes connected instrument and allows the customer to download test results saved on the
instrument, review the results and print test reports. The Sensor Link is compatible with Metrel instruments MI 6201
Multinorm and MI 6401 Poly.
The Sound Link software works as a program for downloading, storing and retrieving measurement data from Metrel
instruments MI 6201 Multinorm and MI 6301 FonS.
PC SOFTWARE PC SOFTWARE
Table with downloaded results of all
connected probes
Draw a graphs of logged parameters
Measurements dialog offering wide
range of available recorded measure-
ments from instrument to be added or
removed from analysis.
SoundLink PC SW Tool for Analysing and
Reporting
Add/remove measurements dialog:
In the same dialog you can select or
deselect measurements that will be
displayed in the table of Results win-
dow.
Export of test results: test results can
be exported to other programs (MS Ex-
cel, MS Word).
Test Reports: automatic generation of
test reports from the selected views
and data with attached graphs.
PC SW SoundLink is compatible with:
MI 6201 Multinorm
MI 6301 FonS
Indoor Environment Quality Indoor Environment Quality
6. 14 6. 15 Accessories: page 6.14 Accessories: page 6.14
Selection Guide for IEQ Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

6
4
0
1
M
I

6
3
0
1
M
I

6
2
0
1
A 1165
Sound calibrator,
class 2
Sound calibrator Class 2 is intended for periodical calibration and accuracy inspec-
tion of the instrument.

A 1152
Sound calibrator,
class 1
Sound calibrator Class 1 is intended for periodical calibration and accuracy inspec-
tion of the instrument.

A 1180 CO
2
probe Probe measures concentration of carbon dioxide in the ambient air.
A 1181 CO probe Probe measures concentration of carbon monoxide in the ambient air.
A 1127
Humidity and tem-
perature probe
Probe for simultaneous relative humidity and air temperature measurements.
A 1131
Black globe thermom-
eter
Black globe thermometer serves for indoor temperature comfort measurements.
A 1132 Luminance probe
Luminance probe performs measurement of luminance i.e. light reected from
the surface.

A 1128
Thermocouple probe,
type K
Type K thermocouple probe with measuring range from -20 C to 1400 C for
contact temperature measurements of various surfaces like motors, transform-
ers, etc.

A 1083
Power supply adapter
with 6 pcs NiMH bat-
teries, type AA
Battery charger and a set of 6 pieces of rechargeable batteries, type AA.
A 1160
Fast charger for 8 AA
batteries with a set of
6 NiMH bat., type AA
Fast battery charger for up to 8 pieces of AA rechargeable batteries, and a set of
6 pcs NiMH rechargeable batteries, type AA.

A 1169
Fast charger for AA,
C, D and 9 V block
batteries
Fast battery charger for up to 12 pcs AA, 6 pcs C or D rechargeable batteries, 4
pcs 9 V block batteries.

A 1130
Telescopic rod with
2.5 m cable
The extension rod helps at measurements on remote spots like ventilation ducts
and other places that cannot be easily reached by hand.

Selection Guide for IEQ Accessories
Option Not available
Photo
Part
number
Description Target application
M
I

6
4
0
1
M
I

6
3
0
1
M
I

6
2
0
1
A 1145
Extension cable for A
1092 and A 1132, 1 m
1 m long extension cable can be used in combination with luminance and illumi-
nance probe for measurements on remote spots.

A 1159 Tripod
Tripod is used for instrument xing at long term measurements of sound and
other indoor air quality parameters.

A 1161
Tripod holder for black
globe thermometer
Tripod holder assures xing of the test instrument and Black globe thermometer
on tripod.

A 1162
PC SW SoundLink
PRO
SoundLink PRO is a complete PC software for downloading, test data evaluation,
profound sound analysis and test report creation.

Accessories: page 7.30
Indoor Environment Quality
6. 16 Accessories: page 6.14
GOOD TO KNOW
Digital Multimeters / Clamp Meters / Voltage and Continuity Tester 7 - 02
DIGITAL MULTIMETERS
Selection Guide for Digital Multimeters 7 - 03
MD 9060 TRMS, 500.000 counts LCD, 100kHz Voltage Bandwidth
Heavy Duty Industrial Multimeterr 7 - 06
MD 9050 TRMS Heavy Duty Industrial Digital Multimeter 7 - 08
MD 9040 TRMS Industrial Digital Multimeter 7 - 09
MD 9035 Automotive Multimeter Designed to Work On Real-World
Car Signals 7 - 10
MD 9030 TRMS General Purpose Digital Multimeter 7 - 11
MD 9020 General Purpose Digital Multimeter 7 - 12
MD 9016 Electrical Field Service Multimeter 7 - 13
MD 9015 Electrical Field Service Digital Multimeter 7 - 14
MD 9010 General Purpose Autocheck Digital Multimeter 7 - 15
CLAMP METERS
Selection Guide for Clamp Meters 7 - 16
MD 9270 Leakage Clamp TRMS Meter with Power Functions 7 - 18
MD 9250 Industrial TRMS AC/DC CAT IV /1000 V 7 - 19
MD 9240 TRMS Power Clamp Meter 7 - 20
MD 9235 TRMS Power Clamp Meter, 3-Phase, Unbalanced-Load 7 - 21
MD 9230 Industrial TRMS AC/DC Current Clamp Meter 7 - 22
MD 9225 Most Complete Industrial TRMS AC/DC
Current Clamp Meter 7 - 23
MD 9220 TRMS Current Clamp Meter 7 - 24
MD 9210 Mini Clamp Meter 7 - 25
VOLTAGE AND CONTINUITY TESTER
Selection Guide for Voltage and Continuity Testers 7 - 26
MD 1155 LED Voltage / Continuity Tester NEW 7 - 27
MD 1055 LCD Voltage / Continuity Tester NEW 7 - 28
NON CONTACT VOLTAGE DETECTORS
MD 115 Non Contact Voltage Detector 7 - 29
MD 105 Non Contact Voltage Detector 7 - 29
Selection Guide for DMM Accessories 7 - 30
D
i
g
i
t
a
l

M
u
l
t
i
m
e
t
e
r
s

/

C
l
a
m
p

M
e
t
e
r
s

/

V
o
l
t
a
g
e

a
n
d

C
o
n
t
i
n
u
i
t
y

T
e
s
t
e
r
s
L
a
b
r
a
t
o
r
y

a
n
d

F
i
e
l
d

T
e
s
t
i
n
g

E
q
u
i
p
m
e
n
t

f
o
r

E
l
e
c
t
r
i
c
a
l

P
a
r
a
m
e
t
e
r
s

MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2014
MI 6401
Poly
MI 6301
FonS
MI 6201
Multinorm
Study the world
Capture the elements
Environmental testing made easy
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 2 7. 3 Accessories: page 7.30 Accessories: page 7.30
Multimeter/Clamp/Voltage and Continuity Testers Multimeter/Clamp/Voltage and Continuity Testers
Find out more about DMMs and
Clamp Meters.
Handheld digital multimeters (DMM)
are among the most widely used instru-
ments for equipment testing when it
comes to servicing, repairing, and install-
ing applications.
A DMM is a digital meter that is capa-
ble of making various types of measure-
ment. It may have any number of special
features, but mainly a DMM measures
volts, ohms, and amperes. DMMs are
used to troubleshoot electrical problems
in a wide array of industrial and house-
hold devices such as batteries, motor
controls, appliances, power supplies,
and wiring systems.
Metrel DMMs are appropriate for test-
ing under tough conditions and can be
tossed into tool cases.
When choosing a clamp meter not only
look at specications, but also pay at-
tention to features, functions, and the
overall value represented by a meters
design:
Choose a clamp meter that gives ac-
curate and repeatable results.
For precise measurements choose
a clamp meter which reports TRMS
reading. Otherwise noise from every-
thing from a variable frequency drive
to compact uorescent bulbs can re-
sult in a less accurate reading.
Make sure that the clamp meter is
specied to work in the environment
you do and that are rugged enough to
continue to give reliable results even in
case they drop from ladders or bounc-
ing in your tool case.
Be sure the clamp meter display has
large, easy to read characters.
RMS (Root Mean Square) value
When an AC supply is placed onto a cir-
cuit, it produces heat. The RMS value is
the equivalent DC supply that would pro-
duce the same amount of thermal heat
as the actual AC supply.
TRMS (True RMS) value
TRMS is a specic method of measuring
the RMS value of a signal. With induc-
tive and capacitive systems distorting
the sinusoidal wave of the mains supply,
this method provides the most accurate
RMS value regardless of the shape of
the waveform.
Resolution
Resolution is the smallest possible
change in a signal that would produce
a change in the value on the screen of
the test instrument. For example, if the
DMM has a resolution of 1 mV on the 4
V range, it is possible to see a change of
1 mV (1/1000 of a volt) while reading 1 V.
Accuracy
Accuracy is a value to show how accu-
rately an instrument can read a specic
value. This is usually written as a per-
centage (e.g. 5 V 5 %). An accuracy of
one percent of reading means that for a
displayed reading of 100 volts, the actual
value of the voltage could be anywhere
between 99 volts and 101 volts.
Number of Counts
The number of divisions into which a
given measuring range is divided. This
can be used to evaluate the resolution of
an instrument.
The basics of measurements
DC and AC voltage
One of the most basic tasks of a DMM
is measuring voltage. A typical DC volt-
age source are the batteries while AC
voltage is usually created by a generator.
The wall outlets are common sources of
AC voltage.
Testing for proper supply voltage is usu-
ally the rst step when troubleshooting
a circuit. If there is no voltage present,
or if it is too high or too low, the voltage
problem should be corrected before in-
vestigating further.
GOOD TO KNOW GOOD TO KNOW
A DMMs ability to measure AC volt-
age can be limited by the frequency of
the signal. Most DMMs can accurately
measure AC voltages with frequencies
from 50 Hz to 500 Hz, but a DMMs AC
measurement bandwidth may be hun-
dreds of kilohertz wide. Such a meter
may read a higher value because it is
capable to see more of a complex ac sig-
nal. DMM accuracy specications for AC
voltage and AC current should state the
frequency range along with the ranges
accuracy.
Frequency is measured in hertz (Hz) the
number of times per second a waveform
repeats. Maintaining the right frequency
is crucial for devices that rely on AC volt-
age and current.
Crest factor
The crest factor describes the ratio of the
peak value to the RMS value of an electrical
variable (AC voltage and AC current).
High crest factors cause distortion
of the reactive power and harmon-
ics in the supply network, and so are
undesirable.
Resistance
Resistance values can vary greatly, from
a few milliohms (m) for contact resist-
ance to billions of ohms for insulators.
Most DMMs measure from 0.1 , up
to 300 M. At Metrel DMM display is
innite resistance (open circuit) read as
OL and means that the resistance is
greater than the meter can measure. Re-
sistance measurements must be made
with the circuit power off otherwise,
the meter or circuit could be damaged.
Continuity
Continuity is a quick go/no-go resist-
ance test that distinguishes between an
open and a closed circuit. A DMM with
a continuity beeper allows you to com-
plete many continuity tests easily and
quickly. The DMM will beep if there is
good continuity, or a good path that al-
lows current to ow. If there is no conti-
nuity, the DMM wont beep.
Diode test
This mode measures and displays the
actual voltage drop across a junction. A
silicon junction should have a voltage
drop less than 0.7 V when applied in the
forward direction and an open circuit
when applied in the reverse direction.
When the red (+) lead is connected to
the anode and the black (-) to the cath-
ode, the diode should conduct and the
meter will display a value (usually the
voltage across the diode in mV, 1000mV
= 1V). After rversing the connections
the diode should not conduct this way
so the meter will display OL.
Capacitance
To test capacitance, set the dial on the
DMM to the capacitance function and
plug in your leads. After ensuring that
the capacitor has been discharged, con-
nect the test leads to the capacitor ter-
minals and take a reading. If the meas-
urement is similar to the rating listed on
the capacitor, the capacitor is good. A
signicant variation from the rating indi-
cates the capacitor should be replaced.
DC and AC current
Current measurements are different
from other DMM measurements. Cur-
rent measurements taken with the
DMM alone require placing the meter in
series with the circuit being measured.
This means opening the circuit and using
the DMM test leads to complete the cir-
cuit. This way all the circuit current ows
through the DMMs circuitry.
Current with Clamp Meter
Todays clamp meters are capable of
measuring both AC and DC current.
Typical current measurements are taken
on various branch circuits of an electri-
cal distribution system. By taking current
measurements along the run of a branch
circuit, it can be easily determined how
much each load along the branch circuit
is drawing from the distribution system.
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 4 7. 5 Accessories: page 7.30 Accessories: page 7.30
Selection Guide for Multimeters
Part No.: MD 9060 MD 9050 MD 9040 MD 9035 MD 9030 MD 9020 MD 9016 MD 9015 MD 9010
True RMS
DC current range (A) 10 10 10 10 10 10 8 10 0.002
Basic accuracy (%) 0.15 0.2 0.2 0.7 1.2 1.2 0.5 0.8 1.2
Maximum resolution (A) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
AC current range (A) 10 10 10 10 10 10 8 10 0.002
Basic accuracy (%) 0.5 0.6 0.6 2.2 1.5 1.5 1.0 1 1.5
Maximum resolution (A) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
DC voltage range (V) 1000 1000 1000 1000 1000 1000 1000 1000 600
Basic accuracy (%) 0.02 0.06 0.06 0.4 0.3 0.3 0.4 0.3 0.5
Maximum resolution (V) 10 10 10 10 100 100 10 100 1000
AC voltage range (V) 1000 1000 1000 1000 1000 1000 1000 750 600
Basic accuracy (%) 0.3 0.5 0.5 2.0 1.5 1.5 1.0 1 1.5
Maximum resolution (V) 10 10 10 10 100 100 10 100 1000
Resistance measurement (M) 50 60 60 60 40 40 60 25 6
Basic accuracy (%) 0.07 0.1 0.1 0.5 0.6 0.6 0.5 0.4 1
Maximum resolution (m) 100 100 100 100 100 100 100 100 100
Acoustic continuity test
Diode test
Capacitance
Frequency measurement
Frequency of digital signals
Temperature measurement (Type K sensor)
T1 & T2
(temperature comparison)
T1 & T2
(temperature comparison)
T1 T1 T1 T1 T1
Autocheck

V /
Conductance (nS)
IP-RPM (Inductive pickup type)
IG-RPM (Contact signal type)
Dwell Angle function
% - Duty Function
Fuel injection ms detector
100 kHz Voltage Bandwidth
Variable frequency drive
Count
50.000 (fast mode)
500.000 (DCV)
99.999 (Hz)
9999 (AC/DCV, Hz, nS)
6000 (mV, /m/A, , F)
6000 4000 4000 6000 2500 6000
Backlight
Analogue bar-graph 41 segment 41 segment 41 segment 24 segment 24 segment
IR, RS232 interface
Automatic and manual range selection Auto
Automatic switch off
Non-contact eletrical eld detection (EF)
MAX hold
Peak hold
Data hold
Recording (MAX / MIN / AVG)
Relative value
Compensation for test leads
Overvoltage category CAT IV / 1000 V CAT IV / 1000 V CAT IV / 1000 V CAT II / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT II / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT II / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT II / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT II / 1000 V
CAT III / 300 V
CAT II / 600 V
Dimensions with holster (mm) 208 x 103 x 64.5 208 x 103 x 64.5 208 x 103 x 64.5 161 x 80 x 50 198 x 97 x 55 198 x 97 x 55 161 x 80 x 50 160 x 82 x 48 113 x 53 x 10.2
Weight with holster (g) 635 635 635 340 396 396 340 345 78
CE mark
DIGITAL MULTIMETERS DIGITAL MULTIMETERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 6 7. 7 Accessories: page 7.30 Accessories: page 7.30
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diode test;
Mains supply frequency measure-
ment;
Frequency of digital signals measure-
ment;
Continuity test (acoustic signaling);
Conductance measurement;
Temperature measurement.
KEY FEATURES:
TRMS: accurate readings on sinusoidal
and non-sinusoidal signals.
VFD: feature makes the instrument ca-
pable of measuring the true values in
accordance with frequency.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Temperature measurement: meas-
ures T1, T2 and T1 + T2 temperature
in Celsius and in Fahrenheit.
Lead alert: incorrect lead connection
alert.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
MAX/MIN/AVG: recording of maxi-
mum, minimum and average values.
Data Hold: data hold feature freezes
the display for later view.
Peak Hold: Crest (instantaneous peak)
capture mode.
PC Link: test results can be download-
ed to the computer via the optional PC
software.
Safety: CAT IV / 1000 V overvoltage
protection.
Backlight: large bright 4 digits 500.000
counts dual LCD display with backlight
for working in dark conditions.
APPLICATION:
High level industrial testing;
High level electronic fault nding;
The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD
9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accord-
ance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT
IV / 1000 V, TRMS current and voltage measurement, conductance measurement and fast one-handed operation. MD
9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak
with extra fast 1ms response time, auto power off, frequency lter, reset and relative function.
The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair
and maintenance practice.
Function Range Accuracy
TRMS AC and AC+DC voltage (20 Hz 40kHz) 500.00 mV 1000.0 V
from (0.45% of reading + 40 digits)
to (4.0% of reading + 40 digits)
DC Voltage 500.00 mV 1000.0 V
from (0.02% of reading + 2 digits)
to (0.15% of reading + 2 digits)
AC Voltage (20 Hz 100 kHz) 500.00 mV 1000.0 V
from (0.3% of reading + 20 digits)
to (4.0% of reading + 40 digits)
DC Current 500.00 A 10.000 A
from (0.15% of reading + 20 digits)
to (0.5% of reading + 20 digits)
TRMS AC and AC+DC Current (40 Hz 100 kHz) 600.0 A 10.00 A
from (0.5% of reading + 50 digits)
to (5.0% of reading + 50 digits)
Diode Test
2.0000 V (1.0% of reading + 1 digit)
Open-circuit voltage < 3.5 V DC, Test current 0.4 mA
Resistance 500.00 50.000 M
from (0.07% of reading + 10 digits)
to (2.0% of reading + 6 digits)
Conductance 99.99 nS (2.0% of reading + 10 digits)
Capacitance 50.00 nF 25.00 mF
from (0.8% of reading + 3 digits)
to (6.5% of reading + 5 digits)
Temperature
-50.0 C 1000.0 C (0.3% of reading + 1.5 C)
-58.0 F 1832.0 F (0.3% of reading + 3.0 F)
Variable Frequency Drive AC 5 Hz 440 Hz
from (2.0% of reading + 50 digits)
to (6.0% of reading + 80 digits)
Frequency of digital equipment 5.000 Hz 1.0000 MHz (0.002% of reading + 4 digits)
Mains frequency 10 Hz 200 kHz (0.02% of reading + 4 digits)
Power supply 9V battery (NEDA1604G, JIS006P, or IEC6F22)
Overvoltage category CAT IV / 1000 V
Dimensions 208 x 103 x 64.5 mm
Weight 635 g
Field servicing;
Heavy duty electrical testing.
STANDARD SET:
Multimeter MD 9060 with rubber holster
Test lead with probe, 2 pcs
Thermocouple probe, type K
9 V battery,
Instruction manual
Warranty
TECHNICAL SPECIFICATION:
DIGITAL MULTIMETERS DIGITAL MULTIMETERS
MD 9060 TRMS, 500.000 counts LCD, 100 kHz Voltage Bandwidth
Heavy Duty Industrial Multimeter
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 8 7. 9 Accessories: page 7.30 Accessories: page 7.30
MD 9050 TRMS Heavy Duty Industrial Digital Multimeter
The MD 9050 ranks among the best multimeters on the market. High resolution and accuracy, 2-line LCD display, fast data acquisi-
tion and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, non-contact voltage detection,
conductance measurement, auto check function and fast one-handed operation are highlights of the multimeter. The MD 9050
is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance
practice.
TECHNICAL SPECIFICATION:
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Mains supply frequency measurement;
Frequency of digital signals measurement;
Continuity test (acoustic signalling);
Conductance measurement;
Electric eld detection;
Temperature measurement.
KEY FEATURES:
TRMS: accurate readings on sinusoidal
and non-sinusoidal signals.
Autocheck function: automatic de-
tection of AC voltage, DC voltage or
resistance.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Temperature measurement: meas-
ures T1, T2 and T1 + T2 temperature
in Celsius and in Fahrenheit.
EF detection: non-contact and probe-
contact electric eld detection.
Lead alert: incorrect lead connection alert.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
MAX/MIN/AVG: recording of maxi-
mum, minimum and average values.
Data Hold: data hold feature freezes
the display for later view.
Peak Hold: Crest (instantaneous peak)
cupture mode.
PC Link: test results can be download-
ed to the computer via the optional PC
software.
Safety: CAT IV / 1000 V overvoltage
protection.
Backlight: large bright 4 digits 9999
counts dual LCD display with backlight
for working in dark conditions.
APPLICATION:
High level industrial testing;
High level electronic fault nding;
Field servicing;
Heavy duty electrical testing.
STANDARD SET:
Multimeter MD 9050 with rubber holster
Test lead with probe, 2 pcs
Thermocouple probe, type K
9 V battery
Instruction manual
Warranty
Function Range Accuracy
TRMS AC and AC+DC voltage
(40 Hz 20 kHz)
60.00 mV 999.9 V
from (0.5 % of reading + 3 digits)
to (3.0 % of reading + 4 digits)
Autocheck (ACV) 9.999 V 999.9 V (1.0 % of reading + 4 digits)
DC voltage 60.00 mV 999.9 V
from (0.06 % of reading + 2 digits)
to (0.12 % of reading + 2 digits)
Autocheck (DCV) 9.999 V 999.9 V (0.5 % of reading + 3 digits)
DC current 600.0 A 10.00 A (0.2 % of reading + 4 digits)
TRMS AC and AC+DC current
(40 Hz 1 kHz)
600.0 A 10.00 A
from (0.6 % of reading + 3 digits)
to (1.0 % of reading + 4 digits)
Diode test
2.000 V (1.0 % of reading + 1 digit)
Open-circuit voltage <3.5 VDC, test current 0.4 mA
Resistance 600.0 60.00 M
from (0.1 % of reading + 3 digits)
to (1.5 % of reading + 5 digits)
Conductance 99.99 nS (0.8 % of reading + 10 digits)
Autocheck (resistance) 600.0 60.00 M
from (0,5 % of reading + 4 digits)
to (2 % of reading + 5 digits)
Mains frequency 15.00 Hz 50.00 kHz (0.04 % of reading + 4 digits)
Frequency of digital equipment 5.00 Hz 1.000 MHz (0.004 % of reading + 4 digits)
Capacitance 60.00 nF 25.00 mF
from (0.8 % of reading + 3 digits)
to (6.5 % of reading + 5 digits)
Temperature -50 C +1000 C (0.3 % of reading +2 C)
Power supply 9 V battery (NEDA1604G, JIS006P, or IEC6F22)
Overvoltage category CAT IV / 1000 V
Dimensions 208 x 103 x 64.5 mm
Weight 635 g
DIGITAL MULTIMETERS
TECHNICAL SPECIFICATION:
MD 9040 TRMS Industrial Digital Multimeter
CAT IV / 1000 V overvoltage category and TRMS measurement of AC current and voltage are key features of the MD 9040.
Thats why it is particularly suitable for performing measurements on power supply sources in the most demanding ap-
plications in the industrial sector. Its high accuracy, 2-line LCD display, diverse measurement functions, fast one-handed
operation and outstanding value for money open up a wide range of possible uses.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Mains supply frequency measurement;
Frequency of digital signals measurement;
Continuity test (acoustic signalling).
KEY FEATURES:
TRMS: accurate readings on sinusoidal
and non-sinusoidal signals.
Lead alert: incorrect lead connection
alert.
Auto-ranging: user can switch between
auto and manual ranging.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
MAX/MIN/AVG: recording of maxi-
mum, minimum and average values.
Data Hold: data hold feature freezes
the display for later view.
PC Link: test results can be download-
ed to the computer via the optional PC
software.
Frequency measurement: up to 1
MHz.
Safety: CAT IV / 1000 V overvoltage
protection.
Easy to read: large bright 4 digits 9999
counts dual LCD display.
APPLICATION:
High level industrial testing;
High level electronic fault nding;
Field servicing;
Heavy duty electrical testing.
STANDARD SET:
Multimeter MD 9040 with rubber holster
Test lead with probe, 2 pcs
9 V battery
Instruction manual
Warranty
Function Range Accuracy
TRMS AC voltage
(40 Hz 20 kHz)
60.00 mV 999.9 V
from (0.5 % of reading + 3 digits)
to (3.0 % of reading + 4 digits)
DC voltage 60.00 mV 999.9 V
from (0.06 % of reading + 2 digits)
to (0.12 % of reading + 2 digits)
DC current 600.0 A 10.00 A (0.2 % of reading + 4 digits)
TRMS AC current
(40 Hz 1 kHz)
600.0 A 10.00 A
from (0.6 % of reading + 3 digits)
to (1.0 % of reading + 4 digits)
Diode test
2.000 V (1.0 % of reading + 1 digit)
Open-circuit voltage <3.5 VDC, Test current 0.4 mA
Resistance 600.0 60.00 M
from (0.1 % of reading + 3 digits)
to (1.5 % of reading + 5 digits)
Mains frequency 15.00 Hz 50.00 kHz (0.04 % of reading + 4 digits)
Frequency of digital equipment 5.00 Hz 1.000 MHz (0.004 % of reading + 4 digits)
Capacitance 60.00 nF 25.00 mF
from (0.8 % of reading + 3 digits)
to (6.5 % of reading + 5 digits)
Power supply 9 V battery (NEDA1604G, JIS006P, or IEC6F22)
Overvoltage category CAT IV / 1000 V
Dimensions 208 x 103 x 64.5 mm
Weight 635 g
DIGITAL MULTIMETERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 10 7. 11 Accessories: page 7.30 Accessories: page 7.30
TECHNICAL SPECIFICATION:
MD 9030 TRMS General Purpose Digital Multimeter
The MD 9030 TRMS digital multimeter has been designed for use both in the laboratories and in the harsh industrial main-
tenance and repair sector. TRMS functionality makes the multimeter suitable for a multitude of situations, while the large
bright screen with backlight and incorrect lead connection alert make it ideal for working in dark areas.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Frequency measurement;
Continuity test (acoustic signalling);
Temperature measurement.
KEY FEATURES:
TRMS: accurate readings on sinusoidal
and non-sinusoidal signals.
Temperature measurement: meas-
ures temperature in Celsius up to 300
C and in Fahrenheit up to 572 F.
Frequency measurement: up to 1 MHz.
Lead alert: incorrect lead connection alert.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Data Hold: data hold feature freezes
the display for later view.
MAX Hold: MAX hold feature freezes
the maximum measured value.
Safe: CAT IV / 300 V, CAT III / 600 V and
CAT II / 1000 V overvoltage protection.
Backlight: large bright 3-3/4 digits,
4000 counts LCD display with back-
light for working in dark conditions.
APPLICATION:
Mid level electrical testing;
Mid level electronic fault nding;
Field servicing;
General purpose.
STANDARD SET:
Multimeter MD 9030 with rubber holster
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
Function Range Accuracy
DC voltage 400.0 mV 1000 V
from (0.3 % of reading + 4 digits)
to (1.0 % of reading + 4 digits)
TRMS AC voltage
(50 500 Hz)
400.0 mV 1000 V
from (1.5 % of reading + 5 digits)
to (4.0 % of reading + 5 digits)
DC current 400.0 A 10.00 A
from (1.2 % of reading + 3 digits)
to (2.0 % of reading + 5 digits)
TRMS AC current 400.0 A 10.00 A
from (1.5 % of reading + 4 digits)
to (2.0 % of reading + 6 digits)
Diode test Open-circuit voltage <1.6 VDC, Test current 0.25 mA
Resistance 400.0 40.00 M
from (0.6 % of reading + 4 digits)
to (2.0 % of reading + 4 digits)
Temperature -20 C 300 C (2.0 % of reading + 3 C)
Frequency 50.00 Hz 1.000 MHz (0.5 % of reading + 4 digits)
Capacitance 500.0 nF 3000 F (3.5 % of reading + 6 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Dimensions 198 x 97 x 55 mm
Weight 396 g
DIGITAL MULTIMETERS DIGITAL MULTIMETERS
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diode test;
Both IP (inductive) & IG (contact) RPM;
ms Fuel-injection on time;
% Duty cycle;
Dwell angle;
Line-Level Hz (ACV, DCV);
Frequency measurement;
Continuity test (acoustic signaling);
Electric eld detection;
Temperature measurement.
KEY FEATURES:
Line-Level: measures frequency from
10 Hz to 50 kHz.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Hold: data hold function freezes the
display for later view.
Pickup clip: Inductive pickup clip ac-
cessory for IP-RPM Function.
4 Selectable Trigger-Levels: For IP-
RPM, IG-RPM, Dwell, %-Duty and ms
Functions.
Selectable Trigger: Positive (+) or
Negative (-) Trigger for %-Duty and ms
Functions.
Selectable Cylinders: 1, 2, 3, 4, 5, 6,
8, 10 or 12 Cylinders for Dwell and IG-
RPM functions.
Safe: CAT II / 1000 V, overvoltage pro-
tection.
APPLICATION:
Automotive industry;
High level industrial testing;
High level electronic fault nding;
Field servicing.
STANDARD SET:
Multimeter MD 9035 with rubber holster
Test lead with probe, 2 pcs
Thermocouple probe, type K
Inductive pickup clip
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
MD 9035 Automotive Multimeter Designed to Work On Real-World Car Signals
Metrel MD 9035 is a unique automotive multimeter top class with many exciting features, such as: Selectable 4-stroke,
4-DIS/2-stroke, & 2-DIS engine RPM; Selectable Trig (+) / Trig- on % & ms readings; Selectable Sensitivity-Levels on RPM,
Dwell, % & ms readings, BeepJack warning, Backlit display and Display hold. MD 9035 is also equipped with automatic
range selection and extra fast analog bar-graph.
TECHNICAL SPECIFICATION:
Function Range Accuracy
DC Voltage 60.00 mV 1000 V
From (0.4% of reading + 3 digits)
to (0.7% of reading + 3 digits)
AC Voltage
(50 Hz 500 Hz)
60.00 mV 1000 V
From (2.0% of reading + 5 digits)
to (2.2% of reading + 5 digits)
DC Current 600.0 A 10.00 A
From (0.7% of reading + 3 digits)
to (0.5% of reading + 3 digits)
AC Current
(50 Hz 500 Hz)
600.0 A 10.00 A
From (2.2% of reading + 5 digits)
to (1.2% of reading + 5 digits)
Diode Test
1.000 V (1.0% of reading + 3 digits)
Open-circuit voltage < 1.6 V DC, Test current 0.50 mA
Resistance 600.0 60.00 M
From (0.5% of reading + 6 digits)
to (1.5% of reading + 5 digits)
Capacitance 6.000 F2000 F
From (2.0% of reading + 5 digits)
to (4.0% of reading + 5 digits)
Temperature
-50 C1000 C (0.5% of reading + 3 digits)
-58 F1832 F (0.5% of reading + 6 digits)
IP-RPM
RPM 4 (24020000 RPM)
(2RPM) RPM 2 (12010000 RPM)
RPM 2M (605000 RPM)
IG-RPM
RPM 4 (6020000 RPM)
(2RPM) RPM 2 (3010000 RPM)
RPM 2M (155000 RPM)
Dwell
0.0 ... 360.0 (1.2 /krpm + 1 digit)
0.0 % 100.0 % (0.04% /krpm /cyl + 2 digits)
Fuel injection-ms detector
PFI / Multi Point Injection
0.05 ms 250.0 ms (0.05 ms + 1 digit)
0.0 % ... 100.0 % (0.04 % /krpm + 2 digits)
TBI / Single Point Injection
0.05 ms ... 250.0 ms (0.05 ms + 1 digit)
0.0 % ... 100.0% (0.04 % /krpm /cyl + 2 digits)
Function Range
Sensitivity
(Sin RMS)
Accuracy
Hz (Line-level)
ACV & DCV
6 V 10 Hz10 kHz 0.5 V
(0.1 %
+ 3 digits)
60 V
10 Hz50 kHz
5 V
600 V 50 V
1000 V 45 Hz1 kHz 500 V
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT II / 1000 V
Dimensions 161 x 80 x 50 mm
Weight 340 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 12 7. 13 Accessories: page 7.30 Accessories: page 7.30
DIGITAL MULTIMETERS
TECHNICAL SPECIFICATION: TECHNICAL SPECIFICATION:
MD 9020 General Purpose Digital Multimeter
The MD 9020 is a high-quality digital multimeter, designed for everyday use in the laboratory and for maintenance and
repair work in the field and in the industrial sector as well.
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Frequency measurement;
Continuity test (acoustic signalling);
Temperature measurement.
KEY FEATURES:
Temperature measurement: meas-
ures temperature in Celsius up to 300
C and in Fahrenheit up to 572 F.
Frequency measurement: up to 1 MHz.
Lead alert: incorrect lead connection alert.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Data Hold: data hold feature freezes
the display for later view.
MAX Hold: MAX hold feature freezes
the maximum measured value.
Safe: CAT IV / 300 V, CAT III / 600 V and
CAT II / 1000 V overvoltage protection.
APPLICATION:
Mid level electrical testing;
Mid level electronic fault nding;
Field servicing;
General purpose.
STANDARD SET:
Multimeter MD 9020 with rubber holster
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
Function Range Accuracy
DC voltage 400.0 mV 1000 V
from (0.3 % of reading + 4 digits)
to (1.0 % of reading + 4 digits)
AC voltage (50 500 Hz) 400.0 mV 1000 V
from (1.5 % of reading + 5 digits)
to (4.0 % of reading + 5 digits)
DC current 400.0 A 10.00 A
from (1.2 % of reading + 3 digits)
to (2.0 % of reading + 5 digits)
AC current 400.0 A 10.00 A
from (1.5 % of reading + 4 digits)
to (2.0 % of reading + 6 digits)
Diode test Open-circuit voltage <1.6 VDC, Test current 0.25 mA
Resistance 400.0 40.00 M
from (0.6 % of reading + 4 digits)
to (2.0 % of reading + 4 digits)
Temperature -20 C 300 C (2.0 % of reading + 3 C)
Frequency 50.00 Hz 1.000 MHz (0.5 % of reading + 4 digits)
Capacitance 500.0 nF 3000 F (3.5 % of reading + 6 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Dimensions 198 x 97 x 55 mm
Weight 396 g
DIGITAL MULTIMETERS
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diode test;
Frequency measurement;
Continuity test (acoustic signaling);
Electric eld detection;
Temperature measurement.
KEY FEATURES:
Auto-ranging: user can switch be-
tween auto and manual ranging.
EF detection: non-contact and probe
contact electric eld detection.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Hold: data hold function freezes the
display for later view.
PC Link: test results can be download-
ed to the computer via the optional PC
software.
Safe: CAT II / 1000 V, CAT III / 600 V and
CAT IV / 300 V overvoltage protection.
APPLICATION:
HVAC (heating, ventilation and air con-
ditioning) troubleshooting;
Low level electrical testing;
Low level electronic fault nding;
Basic eld servicing;
Hobby work.
STANDARD SET:
Multimeter MD 9016 with rubber holster
Test lead with probe, 2 pcs
Thermocouple probe, type K
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
MD 9016 Electrical Field Service Multimeter
The digital multimeter MD 9016 is a perfect combination of size, Innovative functions and built-in PC communication. It
is capable to detect and diagnose most electrical and electrotechnical problems. Display with large easy-to-read gures
and one-handed operation make MD 9016 an extremely easy-to-use. This compact instrument combines a high level of
functionality and small size and portability.
Function Range Accuracy
DC Voltage 60.00 mV 1000 V
from (0.4% of reading + 5 digits)
to (0.2% of reading + 3 digits)
ACVoltage (50 Hz 500 Hz) 60.00 mV 1000 V (1.0% of reading + 5 digits)
DC Current 600.0 A 8.00 A
from (0.5% of reading + 5 digits)
to (1.8% of reading + 6 digits)
AC Current
(50 Hz 400 Hz)
600.0 A 8.00 A
from (1.0% of reading + 3 digits)
to (1.8% of reading + 6 digits)
Diode Test 1.000 V (1.0% of reading + 3 digits)
Open-circuit voltage < 1.8 V DC, Test current 0.56 mA
Resistance 600.0 60.00 M
from (0.5% of reading + 4 digits)
to (1.2% of reading + 4 digits)
Capacitance 60.00 nF 3000 F
from (1.5% of reading + 5 digits)
to (2.0% of reading + 5 digits)
Temperature
-50 C 1000 C (0.3% of reading + 3 digits)
-58 F 1832 F (0.3% of reading + 6 digits)
Frequency of digital equipment 5.00 Hz 1.000 MHz (0.003% of reading + 2 digits)
Mains frequency 10 Hz 50 kHz (0.003% of reading + 3 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Dimensions 161 x 80 x 50 mm
Weight 340 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 14 7. 15 Accessories: page 7.30 Accessories: page 7.30
TECHNICAL SPECIFICATION:
The digital multimeter MD 9015 includes all necessary functions required to detect and diagnose most electrical and elec-
trotechnical problems. Display with large easily-read figures and one-handed operation make MD 9015 an extremely easy
to use. This compact instrument combines a high level of functionality and small size and portability.
MD 9015 Electrical Field Service Digital Multimeter
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Frequency measurement;
Continuity test;
Electric eld detection;
Temperature measurement.
KEY FEATURES:
Temperature: measures temperature
in Celsius up to 300 C and in Fahren-
heit up to 572 F.
Auto-ranging: user can switch be-
tween auto and manual ranging.
EF detection: non-contact and probe-
contact electric eld detection.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Hold: data hold function freezes the
display for later view.
PC Link: test results can be downloaded to
the computer via the optional PC software.
Safe: CAT II / 1000 V, CAT III / 600 V and
CAT IV / 300 V overvoltage protection.
APPLICATION:
HVAC (heating, ventilation and air con-
ditioning) troubleshooting;
Low level electrical testing;
Low level electronic fault nding;
Basic eld servicing;
Hobby work.
STANDARD SET:
Multimeter MD 9015 with rubber holster
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
Function Range Accuracy
DC voltage 250.0 mV 1000 V
from (0.3 % of reading + 4 digits)
to (1.0 % of reading + 4 digits)
AC voltage (50 500 Hz) 250.0 mV 750 V
from (1.0 % of reading + 3 digits)
to (2.2 % of reading + 6 digits)
DC current 250.0 A 10.00 A
from (0.8 % of reading + 3 digits)
to (2.0 % of reading + 6 digits)
AC current 250.0 A 10.00 A
from (1.0 % of reading + 4 digits)
to (2.5 % of reading + 5 digits)
Diode test Open-circuit voltage <1.8 VDC, Test current 1 mA
Resistance 250.0 25.00 M
from (0.4 % of reading + 2 digits)
to (1.0 % of reading + 4 digits)
Temperature -20 C 300 C 3 C + 3 digits
Frequency 30 Hz 200 kHz (0.05 % of reading + 4 digits)
Capacitance 2.500 nF 25.00 F
from (1.0 % of reading + 4 digits)
to (6.0 % of reading + 45 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Dimensions 160 x 82 x 48 mm
Weight 345 g
DIGITAL MULTIMETERS
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diod test;
Frequency measurement;
Continuity test;
Electric eld detection.
KEY FEATURES:
Autocheck function: automatic detection
of AC voltage, DC voltage or resistance.
Auto-ranging: no need of manual
ranging.
Pocket-sized: small, thin, ergonomic design.
Lightweight: 78 g only.
Acoustic signalling on continuity test.
EF detection: non-contact and probe-
contact electric eld detection.
Safe: protected against wrong connec-
tion and overvoltage (CAT III / 300 V
and CAT II / 600 V).
Easy to read: LCD display, 3-5/6 digits,
6000 counts.
APPLICATION:
Low level electrical testing;
Low level electronic fault nding;
Basic eld servicing;
Hobby work.
STANDARD SET:
Multimeter MD 9010 with rubber holster
Test lead with probe, 2 pcs
Battery
Instruction manual
Warranty
MD 9010 General Purpose Autocheck Digital Multimeter
The MD 9010 is one of the smallest and lightest of our digital multimeters. The MD 9010 unit can be used for a wide vari-
ety of applications. The high accuracy, LCD display and features including non-contact voltage detection and an autocheck
function make the multimeter extremely versatile and great value for money.
TECHNICAL SPECIFICATION:
Function Range Accuracy
DC voltage 6.000 V 600.0 V
from (0.5 % of reading + 3 digits)
to (2.0 % of reading + 5 digits)
AC voltage (50 60 Hz) 6.000 V 600.0 V (1.5 % of reading + 5 digits)
DC current
400.0 A
2000 A
(1.5 % of reading + 3 digits)
(1.2 % of reading + 3 digits)
AC current
400.0 A
2000 A
(2.0 % of reading + 3 digits)
(1.5 % of reading + 3 digits)
Diode test Open-circuit voltage <1.6 VDC
Resistance 600.0 6.000 M
from (1.0 % of reading + 4 digits)
to (2.0 % of reading + 6 digits)
Frequency 10.00 Hz 30.00 kHz (0.5 % of reading + 4 digits)
Capacitance 100.0 nF 2000 F (3.5 % of reading + 6 digits)
Power supply 3 V button battery (IEC-CR2032)
Overvoltage category CAT III / 300 V; CAT II / 600 V
Dimensions 113 x 53 x 10.2 mm
Weight 78 g
DIGITAL MULTIMETERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 16 7. 17 Accessories: page 7.30 Accessories: page 7.30
Selection Guide for Clamp Meters
CLAMP METERS
Part No.: MD 9270 MD 9250 MD 9240 MD 9235 MD 9230 MD 9225 MD 9220 MD 9210
True RMS
DC current range 2000 A 1000 A 400 A
Basic accuracy (%) 2.0 1.5 1
AC current range 150 A 2000 A 1000 A 600 A 800 A 400 A 2000 A 600 A
Basic accuracy (%) 0.8 2.0 1 1 1.5 1 1.5 1.5
DC voltage range 1000 600 V 600 V 600 V 600 V 600 V 600 V
Basic accuracy (%) 0.5 0.5 0.5 0.3 0.3 0.5 0.3
AC voltage range 600 V 1000 600 V 600 V 600 V 600 V 600 V 600 V
Basic accuracy (%) 0.5 1.2 0.5 0.5 1 1 1.5 1.5
Resistance range 40.00 M 999.9 999.9 40.00 M 40.00 M 6.000 M 40.00 M
Basic accuracy (%) 0.5 1 1 0.6 0.8 1 0.6
Acoustic continuity test
Diode test
Capacitance measurement
Frequency measurement
Temperature measurement (Type K probe)
Autocheck

V- Auto V-A Auto V-A


Variable frequency drive
Lo-Z (low input impedance)
Power measurement (W, VA, VAR)
3-Phase Power measurement 3-wire/4-wire
Count 3000 6000 4000, 6000, 9999 6000 4000 4000 6000 4000
Backlight
COM port (data transfer)
Automatic and manual range selection Auto Auto Auto Auto Auto
Automatic switch off
Non-contact electrical eld detection
MAX hold
Peak value
Data hold
Relative value
Jaw opening 31 mm 55 mm 45 mm 26 mm 50 mm 26 mm 45 mm 26 mm
Overvoltage category
CAT IV / 300 V
CAT III / 600 V
CAT IV / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
Dimensions (mm) 212 x 59 x 37 264 x 97 x 43 224 x 78 x 40 189 x 78 x 40 227 x 78 x 40 188 x 63 x 40 224 x 78 x 40 190 x 63 x 32
Weight (g) 225 608 224 192 290 192 220 139
CE mark
CLAMP METERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 18 7. 19 Accessories: page 7.30 Accessories: page 7.30
MD 9270 Leakage Clamp TRMS Meter with Power Functions
The MD 9270 is a unique earth leakage clamp meter. It not just has the ability to accurately read the TRMS AC leakage
current of a system, it can also detect losses in the system and suggest possible reasons for the loss. The voltage, power,
harmonic, power factor (PF), total harmonic distortion (THD) and crest factor measurements make this instrument suitable
for any electrician and engineer.
MEASURING FUNCTIONS:
TRMS AC voltage measurement;
TRMS AC current measurement;
Power parameters measurement.
KEY FEATURES:
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
Jaw size: 31 mm.
Shielded Jaw: shielded jaw allows the
clamp meter to be used in the noisiest
environments.
Accurate: readings of AC current with an
accuracy of 0.8 % and a base resolution
of 0.01 mA and voltage with an accuracy
of 0.5 % and a base resolution of 0.1 V.
Power: measures various power pa-
rameters (active, reactive, apparent
power, THD, PF, phase displacement).
Intelligent loss analysis: complex algo-
rithms detect loss and allow determin-
ing possible reasons for current loss.
Harmonics: measures current or voltage
harmonic components and a percentage
value of a harmonic up to the 49
th
.
THD and PF: dual display allows readings
to be displayed along with Total Harmon-
ic Distortion (THD) or Power Factor (PF).
Peak value: the peak value of the wave-
form or crest factor can be displayed.
MAX/MIN/HOLD mode: displays maxi-
mum, minimum or average measured value.
APPLICATION:
Load and leakage current measurement;
System maintenance;
Power system checking;
RCD fault nding;
Process engineering.
STANDARD SET:
Current clamp MD 9270
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Pouch
Instruction manual
Warranty
Function Range Accuracy
AC current
40.00 mA, 400.0 mA, 4000 mA
40.00 A
150.0 A
(0.8 % of reading + 3 digits)
(1.0 % of reading + 3 digits)
(2.0 % of reading + 5 digits)
AC voltage 250.0 V, 600.0 V (0.5 % of reading + 2 digits)
THD
0 99.9 %
100 999 %
(2.0 % of reading + 3 digits)
(2.0 % of reading + 3 digits)
Crest Factor
1.00 2.99
3.00 9.99
(2.0 % of reading + 2 digits)
(3.0 % of reading + 5 digits)
Peak value
0 150.0 A
0 600.0 V
(3.0 % of reading + 3 digits)
(3.0 % of reading + 3 digits)
Power factor (PF) 0.00 1.00 (1.0 % of reading + 0.01)
Phase -180.0 +180.0 (1.0 % of reading + 0.4)
Apparent power
0 9999 VA
10 kVA 999.9 kVA
from(1%of r.+ 0.03) to (1%of r. + 3)
from(2%of r. + 0.03) to (2%of r. + 0.3)
Active power
0 9999 W
10 kW 999.9 kW
from(1%of r.+ 0.03) to (1%of r. + 3)
from(2%of r. + 0.03) to (2%of r. + 0.3)
Reactive power
0 9999 VAr
10 kVAr 999.9 kVAr
from(1%of r.+ 0.03) to (1%of r. + 3)
from(2%of r. + 0.03) to (2%of r. + 0.3)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 212 x 59 x 37 mm
Weight 225 g
TECHNICAL SPECIFICATION:
CLAMP METERS
MD 9250 Industrial TRMS AC/DC CAT IV /1000 V
The MD 9250 is the rst Clamp Meter that meets overvoltage category CAT IV 1000 V. MD 9250 is a high quality clamp
meter specially designed for single-hand operation, built-in measuring functions; TRMS AC/DC (current, voltage), capaci-
tance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in
the industrial sector. The large jaws capacity of (max. 55 mm) in diameter allows AC/DC - current measurements up to 2000
A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer (via optical interface), non-contact
voltage detection, and auto-check function are highlights of the instrument.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diode test;
Frequency measurement;
Electric eld detection;
Continuity test (acoustic signaling);
Temperature measurement.
KEY FEATURES:
Large jaws: for measuring on 55mm
size conductors.
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
VFD: feature makes the instrument ca-
pable of measuring the true values in
accordance with frequency.
High current: 2000 A DC & AC clamp
on measurement.
Lo-Z: AutoCheck

mode provides low


(ramp-up) input impedance to drain
ghost voltages.
Auto-check function: automatic detection
of AC voltage, DC voltage or resistance.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Transient protection: it protects user
in case of lightning strike or switching
surge up to 12 kV.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
PC Link: test results can be downloaded to
the computer via the optional PC software.
In-rush: fast 5ms Crest-MAX mode to
capture in-rush currents.
Temperature: measures temperature
in Celsius up to 1000 C and in Fahren-
heit up to 1832 F.
Hold: data hold function freezes the
display for later view.
Backlight: large bright 3-5/6 digits 6,000
counts + 1,999 counts dual LCD display with
backlight for working in dark conditions.
Safe: CAT IV / 1000 V overvoltage pro-
tection.
APPLICATION:
Solar and wind power system testing;
UPS system testing;
Utility scale battery system testing;
High level industrial testing;
High level electrical testing.
STANDARD SET:
Current clamp MD 9250
Test lead with probe, 2 pcs
Thermocouple probe, type K
Pouch
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
TECHNICAL SPECIFICATION:
CLAMP METERS
Function Range Accuracy
DC Voltage 6.000 V 1000 V (0.5% of reading + 5 digits)
Autocheck (DCV) 6.000 V 1000 V (1.3% of reading + 5 digits)
AC Voltage (50 Hz 400 Hz) 6.000 V 1000 V (1.2% of reading + 5 digits)
AC+DCVoltage (DC, 50Hz 400 Hz) 6.000 V 1000 V (1.4% of reading + 7 digits)
Autocheck (ACV) 6.000 V 1000 V (1.5% of reading + 5 digits)
Variable Frequency Drive AC 10 Hz 400 Hz
from (4.0% of reading + 80 digits)
to (7.0% of reading + 80 digits)
DC Current 200.0 A 2000 A
From (2.0% of reading + 5 digits)
to (2.5% of reading + 5 digits)
AC Current (50 Hz 400 Hz) 200.0 A 2000 A
from (2.0% of reading + 5 digits)
to (3.5% of reading + 5 digits)
Diode Test
1.000 V (1.0% of reading + 3 digit)
Open-circuit voltage < 1.8 V DC, Test current 0.56 mA
Resistance & Autocheck 600.0 40.00 M
from (0.5% of reading + 5 digits)
to (2.3% of reading + 5 digits)
Capacitance 60.00 nF 2000 F
from (2.0% of reading + 5 digits)
to (4.0% of reading + 5 digits)
Temperature
-50 C 1000 C (0.3% of reading + 4 digits)
-58 F 1832 F (0.3% of reading + 6 digits)
Mains frequency 10 Hz 1999 Hz (0.1% of reading + 4 digits)
Power supply 2 x 1.5 V batteries, type AA
Overvoltage category CAT IV / 1000 V
Dimensions 264 x 97 x 43 mm
Weight 608 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 20 7. 21 Accessories: page 7.30 Accessories: page 7.30
MD 9240 TRMS Power Clamp Meter
TECHNICAL SPECIFICATION:
The MD 9240 is a high-quality and extremely easy to handle power clamp meter. The MD 9240 enables TRMS AC current
measurement up to 1000 A, AC and DC voltage measurement, single-phase power analysis, temperature measurement
and more. As a result the current clamp meter is suitable for maintenance and checking of distribution systems, switch-
boards and motors or systems where the supply network is heavily contaminated with harmonics.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC current measurement;
Frequency measurement;
Resistance measurement;
Continuity test;
Temperature measurement;
Power parameters measurement.
KEY FEATURES:
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
Jaw size: 45 mm.
High current: measures up to 1000 A AC.
Autocheck function: automatic de-
tection of AC voltage, DC voltage or
AC current.
Power: measures various power pa-
rameters (active, reactive, apparent
power, PF).
Temperature: measures temperature
in Celsius up to 300 C and in Fahren-
heit up to 572 F.
PC Link: test results can be downloaded to
the computer via the optional PC software.
Data Hold: data hold feature freezes
the display for later view.
Peak Hold: peak hold feature displays
maximum RMS value of surge voltage
or current.
APPLICATION:
System maintenance;
Power system checking;
High level Industrial testing;
High level electrical testing.
STANDARD SET:
Current clamp MD 9240
Test lead with probe, 2 pcs
Thermocouple probe, type K
1.5 V battery, type AAA, 2 pcs
Pouch
Instruction manual
Warranty
Function Range Accuracy
DC voltage 600.0 V (0.5 % of reading + 5 digits)
AC voltage (50 60 Hz; 45
500 Hz; 500 Hz 3.1 kHz)
600.0 V
from (0.5 % of reading + 5 digits),
to (2.5 % of reading + 5 digits)
AC current (50 60 Hz)
40.00 A, 400.0 A,
1000 A
(1.0 % of reading + 5 digits)
AC current (45 500 Hz)
40.00 A, 400.0 A,
1000 A
(2.0 % of reading + 5 digits)
(2.5 % of reading + 5 digits)
AC current (500 Hz 3.1 kHz)
40.00 A, 400.0 A,
1000 A
(2.5 % of reading + 5 digits)
(3.0 % of reading + 5 digits)
Temperature -50 C 300 C (2.0 % of reading + 3 C)
Resistance 999.9 (1.0 % of reading + 6 digits)
Continuity test 10 300
Frequency 5.00 Hz 500.0 Hz (0.5 % of reading + 4 digits)
Power factor (PF) 0.10 0.99
(3 digits), H from 1. to 21.
(5 digits), H from 22. to 51.
Apparent power 0 600.0 kVA
(2.0 % of reading + 6 digits), H 1./10.
(3.5 % of reading + 6 digits), H 11./46.
(5.5 % of reading + 6 digits), H 47./51.
Active power, reactive power 0 600.0 kW, kVar from (2.0 % of reading + 6 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 224 x 78 x 40 mm
Weight 224 g
CLAMP METERS CLAMP METERS
MD 9235 TRMS Power Clamp Meter, 3-Phase, Unbalanced-Load
TECHNICAL SPECIFICATION:
The MD 9235 is a Slim-Jaw current clamp meter with ability to measure 3-Phase Unbalanced-Load + kWHr recording. The
MD 9235 enables TRMS AC current measurement up to 600 A, single and 3-phase power analysis, total power factor and
resistance measurement. Display with large easy-to-read figures and one-handed operation make MD 9235 an extremely
easy-to-use. This compact instrument combines a high level of functionality, small size and portability. All built-in features
make MD 9235 a perfect tool for advanced Power applications.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC current measurement;
Resistance measurement;
Frequency measurement;
Continuity test (acoustic signaling);
Power parameters measurement.
KEY FEATURES:
Slim-Jaws: ultra-slim jaws to access
tight places.
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
kWHr: Kilo-Watt-Hour recording func-
tion (with memory recal).
Peak Hold: peak hold feature displays
maximum RMS value of surge voltage
or current.
Jaw size: 26 mm.
Transient protection: it protects user
in case of lightning strike or switching
surge up to 6.5 Kv.
PC Link: test results can be download-
ed to the computer via the optional PC
software.
Hold: data hold function freezes the
display for later view.
Safe: CAT IV / 300 V, CAT III / 600 V
overvoltage protection.
APPLICATION:
Power system checking;
High level industrial testing;
High level electrical testing.
STANDARD SET:
Current clamp MD 9235
Test lead with probe, 2 pcs
Pouch
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
Function Range Accuracy
DC Voltage 600.0 V (0.5% of reading + 5 digits)
AC Voltage
(50 Hz 3.1 kHz)
600.0 V
from (0.5% of reading + 5 digits)
to (2.5% of reading + 5 digits)
AC Current
(40 Hz 3.1 kHz)
40.00 A 600 A
from (1.0% of reading + 5 digits)
to (3.0% of reading + 5 digits)
Resistance 999.9 (1.0% of reading + 6 digits)
Apparent power
0 kVA 600.0
kVA
(2.0% of reading + 6 digits), H 1./10.
(3.5% of reading + 6 digits), H 11./46.
(5.5% of reading + 6 digits), H 46./51.
Active power, reactive
ppower
0 kVA 600.0
kW, kVar
from (2.0% of reading + 6 digits)
to (10.0% of reading + 6 digits), H 1./10.
from (3.5% of reading + 6 digits)
to (10.0% of reading + 6 digits), H 11./25.
from (4.5% of reading + 6 digits)
to (15.0% of reading + 6 digits), H 26./45.
from (10.0% of reading + 6 digits)
to (15.0% of reading + 6 digits), H 46./51.
Power factor (PF) 0.10 0.99
( 3 digits), H 1./21.
( 5 digits), H 22./51.
Mains frequency 5 Hz 500 Hz (0.5% of reading + 4 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V, CAT III / 600 V
Dimensions 189 x 78 x 40 mm
Weight 192 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 22 7. 23 Accessories: page 7.30 Accessories: page 7.30
CLAMP METERS
MD 9230 Industrial TRMS AC/DC Current Clamp Meter
TECHNICAL SPECIFICATION:
The MD 9230 is a universal current clamp for measuring DC and TRMS AC voltages up to 600 V and DC and TRMS AC cur-
rents up to 1000 A. With a broad spectrum of measuring functions and features, it is an ideal tool for service companies
and works electricians in the industrial sector.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Resistance measurement;
Continuity testing;
Capacitance measurement;
Diod test.
KEY FEATURES:
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
Jaw size: 50 mm.
High current: measures up to 800 A AC
and 1000 A DC.
Auto-ranging: user can switch be-
tween auto and manual ranging.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Data Hold: data hold feature freezes
the display for later view.
MAX Hold: MAX hold feature freezes
the maximum measured value.
Display: easy to read LCD screen, 3-3/4
digits, 4000 counts with backlight.
APPLICATION:
Solar and wind power systems testing;
UPS systems testing;
Utility scale battery systems testing;
High level industrial testing;
High current electrical testing.
STANDARD SET:
Current clamp MD 9230
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Pouch
Instruction manual
Warranty
Function Range Accuracy
DC voltage
400.0 mV,
4.000 V, 40.00 V, 400.0 V,
600.0 V
(0.3 % of reading + 3 digits)
(0.5 % of reading + 3 digits)
(1.0 % of reading + 4 digits)
AC voltage
50 Hz 500 Hz
50 Hz 60 Hz
60 Hz 500 Hz
50 Hz 500 Hz
400.0 mV
4.000 V, 40.00 V, 400.0 V
4.000 V, 40.00 V, 400.0 V
600 V
(4.0 % of reading + 4 digits)
(1.0 % of reading + 4 digits)
(1.5 % of reading + 4 digits)
(2.0 % of reading + 4 digits)
DC current 400.0 A,1000 A
from (1.5 % of reading + 4 digits)
to (5.0 % of reading + 30 digits)
AC current (15 Hz 1 kHz) 400 A, 800 A
from (1.5 % of reading + 4 digits)
to (5.0 % of reading + 30 digits)
Resistance 400.0 40.00 M
from (0.6 % of reading + 4 digits)
to (2.0 % of reading + 4 digits)
Continuity test 400.0 (1.5 % of reading + 6 digits)
Diode test Open-circuit voltage <1.6 VDC, test current 0.4 mA
Capacitance 500 nF 3000 F (3.5 % of reading + 6 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 227 x 78 x 40 mm
Weight 290 g
MD 9225 Most Complete Industrial TRMS AC/DC Current Clamp Meter
TECHNICAL SPECIFICATION:
The MD 9225 is a versatile current clamp meter with perfect combination of size and built-in functions. It measures AC/DC
current and voltage, capacitance, temperature, full range resistance and captures In-rush current. Display with large easy-to-
read figures and one-handed operation make MD 9225 an extremely easy-to-use. This compact instrument combines a high
level of functionality, small size and portability. All built-in features make MD 9225 a perfect tool for advanced applications.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC, DC current measurement;
Capacitance measurement;
Resistance measurement;
Diode test;
Frequency measurement;
Continuity test (acoustic signaling);
Temperature measurement.
KEY FEATURES:
Clamp on + Full Multimeter ranges:
measures current up to 400 A AC/DC.
Jaw size: 26 mm.
In-rush: fast 30 ms Crest-MAX mode
to capture in-rush currents.
Temperature: measures temperature
in Celsius up to 537 C and in Fahren-
heit up to 999 F.
Transient protection: it protects user
in case of lightning strike or switching
surge up to 6.5 kV.
High resolution: 4000 counts enable
fast measurements.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Hold: data hold function freezes the
display for later view.
Safe: CAT IV / 300 V, CAT III / 600 V
overvoltage protection.
APPLICATION:
Solar and wind power system testing;
UPS system testing;
Utility scale battery system testing;
Working in small enclosures.
STANDARD SET:
Current clamp MD 9225
Test lead with probe, 2 pcs
Thermocouple probe, type K
Pouch
1.5 V battery, type AAA, 2 pcs
Instruction manual
Warranty
CLAMP METERS
Function Range Accuracy
DC Voltage 400.0 mV 600 V
From (0.3% of reading + 3 digits)
to (1.0% of reading + 4 digits)
AC Voltage
(50 Hz 500 Hz)
4.000 V 600 V
From (1.0% of reading + 4 digits)
to (2.0% of reading + 4 digits)
DC Current 0.0 A 400.0 A
From (1.0% of reading + 4 digits)
to (2.5% of reading + 5 digits)
AC Current
(40 Hz 400 Hz)
0 A 400 A
From (1.0% of reading + 6 digits)
to (2.5% of reading + 5 digits)
Diode Test Open-circuit voltage < 1.6 V DC, Test current 0.4 mA
Resistance 400.0 ... 40.00 M
From (0.8% of reading + 6 digits)
to (2.0% of reading + 4 digits)
Capacitance 500.0 nF 3000 F (3.5% of reading + 6 digits)
Temperature
-20 C 537 C
From (2.0% of reading + 3 digits)
to (3.0% of reading + 3 digits)
-4 F 1000 F
From (2.0% of reading + 6 digits)
to (3.0% of reading + 6 digits)
Mains frequency 5 Hz 100 kHz (0.5% of reading + 4 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V, CAT III / 600 V
Dimensions 188 x 63 x 40 mm
Weight 218 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 24 7. 25 Accessories: page 7.30 Accessories: page 7.30
CLAMP METERS
MD 9220 TRMS Current Clamp Meter
The MD 9220 is a high-quality TRMS current clamp meter, designed for everyday use in the laboratories and for mainte-
nance and repair work in the field and in the industrial sector.
MEASURING FUNCTIONS:
TRMS AC, DC voltage measurement;
TRMS AC current measurement;
Frequency measurement;
Resistance measurement;
Continuity testing;
Capacitance measurement;
Diod test;
Electric eld detection.
KEY FEATURES:
TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals.
Jaw size: 45 mm.
High specication: readings up to
2000 A with excellent accuracy.
Autocheck function: automatic de-
tection of AC voltage, DC voltage or
resistance.
Auto-ranging: user can switch be-
tween auto and manual ranging.
EF detection: non-contact and probe-
contact electric eld detection.
Data Hold: data hold feature freezes
the display for later view.
Easy to read: large bright LCD screen,
3-5/6 digits, 6000 counts, with back-
light.
APPLICATION:
High powered 3-phase machinery testing;
High level industrial testing;
High current electrical testing.
STANDARD SET:
Current clamp MD 9220
Test lead with probe, 2 pcs
1.5 V battery, type AAA, 2 pcs
Pouch
Instruction manual
Warranty
Function Range Accuracy
DC voltage
6.000 V
60.00 V
600.0 V
(0.5 % of reading + 3 digits)
(1.0 % of reading + 5 digits)
(2.0 % of reading + 5 digits)
AC voltage (50, 60 Hz)
6.000 V, 60.00 V
600.0 V
(1.5 % of reading + 5 digits)
(2.0 % of reading + 5 digits)
AC voltage (50 500 Hz)
6.000 V, 60.00 V
600.0 V
(2 % of reading + 5 digits)
(2.5 % of reading + 5 digits)
AC current (50, 60 Hz) 400.0 A, 2000 A (1.5 % of reading + 5 digits)
Resistance
6.000 k
60.00 k, 600.0 k
6.000 M
(1.2 % of reading + 6 digits)
(1.0 % of reading + 4 digits)
(2.0 % of reading + 4 digits)
Continuity test 600.0 (2.0 % of reading + 8 digits)
Diode test Open-circuit voltage <1.6 VDC, test current 0.4 mA
Frequency 10 Hz 30 kHz (0.5% of reading + 4 digits)
Capacitance 100.0 nF 2000 F (3.5% of reading + 5 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 224 x 78 x 40 mm
Weight 220 g
TECHNICAL SPECIFICATION:
CLAMP METERS
MD 9210 Mini Clamp Meter
TECHNICAL SPECIFICATION:
Versatility, sturdy case, high accuracy and lots of measurement functions are key features of the current clamp MD 9210.
This universal current clamp offers good value for money.
MEASURING FUNCTIONS:
AC, DC voltage measurement;
AC current measurement;
Frequency measurement;
Resistance measurement;
Continuity testing;
Capacitance measurement;
Diod test.
KEY FEATURES:
Jaw size: 26 mm.
Lightweight: 139 g only.
High specication: readings up to 600
A with excellent accuracy.
Auto-ranging: no need of manual
ranging.
Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
Data Hold: data hold feature freezes
the display for later view.
MAX Hold: MAX hold feature freezes
the maximum measured value.
Easy to read: large bright 3-3/4 digits
4000 counts LCD display.
APPLICATION:
Working in small enclosures;
General purpose;
3-phase machinery testing.
STANDARD SET:
Current clamp MD 9210
Test lead with probe, 2 pcs
3 V battery
Pouch
Instruction manual
Warranty
Function Range Accuracy
DC voltage
400.0 mV
4.000 V, 40.00 V, 400.0 V
600 V
(0.3 % of reading + 4 digits)
(0.5 % of reading + 3 digits)
(1.0 % of reading + 4 digits)
AC voltage (50 Hz 500 Hz)
4.000 V, 40.00 V, 400.0 V
600 V
(1.5 % of reading + 5 digits)
(2.0 % of reading + 5 digits)
AC current (50 / 60 Hz) 40.00 A, 400.0 A, 600 A (1.5 % of reading + 8 digits)
Resistance
400.0
4.000 k, 40.00 k, 400.0 k
4.000 M
40.00 M
(0.8 % of reading + 8 digits)
(0.6 % of reading + 4 digits)
(1.0 % of reading + 4 digits)
(2.0 % of reading + 4 digits)
Diode test Open-circuit voltage <1.6 VDC, test current 0.25 mA
Frequency 10 Hz 100 kHz (0.5 % of reading + 4 digits)
Capacitance 500.0 nF 3000 F (3.5 % of reading + 6 digits)
Power supply 3 V battery (IEC-CR2032)
Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 190 x 63 x 32 mm
Weight 139 g
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 26 7. 27 Accessories: page 7.30 Accessories: page 7.30
Selection Guide for Voltage detectors
Part No.: NEW MD 1155 NEW MD 1055
AC VOLTAGE
Test Range 3 V 1000 V 6 V 1000 V
Operation time Max. 30s Max. 30s
Response Time <1s <1s
Frequency Range 0 1000 Hz 0 1000 Hz
DC VOLTAGE
Test Range 4 V 1400 V 6 V 1400 V
Operation time Max. 30s Max. 30s
Response Time <1s <1s
RESISTANCE & CONTINUITY TEST
Indication
Acoustical and LCD
indication
Acoustical and LED
indication
Resistance range 0 2 k 5% 0 - 50 k
Continuity test (Acoustic) Up to 50 Up to 50
Test current 80uA 8uA
RCD TRIGGER TEST
RCD fault test for tripping 30 mA RCD (max 240V) for tripping 30 mA RCD (max 240V)
Phase TESTING
Phase Testing Single-Pole Phase testing Single-Pole Phase testing
Phase Sequence
Two-Pole Phase
Sequence testing
Two-Pole Phase
Sequence testing
Phase indication >100 V AC >100 V AC
DISPLAY
Type 3 digit, LC display with backlight LED bargraph
Tolerance 6 V 1000 V (2% rdg. + 3D)
12 V, 24 V, 48 V, 120 V, 230 V, 400 V, 690
V,1000 V
TORCH LAMP LED LED
SAFETY & PROTECTION
Overload Category CAT IV 1000 V CAT IV 1000 V
Compliant to standards
IEC/EN 61243-3,
DIN VDE 0682-401
IEC/EN 61243-3,
DIN VDE 0682-401
Protection degree
IP65
For outdoor use:
Water jet and dust
tight protection
IP65
For outdoor use:
Water jet and dust
tight protection
TEMPERATURE RANGE -10 + 55 C -10 + 55 C
POWER SUPPLY
Battery type 2 x 1,5 V Type AAA Micro 2 x 1,5 V Type AAA Micro
DIMENSIONS
300 x 75 x 20 mm 300 x 75 x 20 mm
270 g 270 g
VOLTAGE AND CONTINUITY TESTERS
MD 1155 LCD Voltage / Continuity Tester
The MD 1155 is a high-quality voltage / continuity tester designed for the most demanding duties. With a broad spectrum
of measurement functions and CAT IV / 1000 V overvoltage category, the device is suitable for both the industrial sector
and for everyday maintenance and repair practice.
MEASURING FUNCTIONS:
AC, DC voltage testing;
Phase testing;
Rotary eld testing;
Continuity testing;
RCD trip-out test.
KEY FEATURES:
3 V 1000 V AC TRMS voltage range.
4 V ... 1400 V DC voltage range.
Data hold function.
LCD display with backlight.
Phase rotation measurement.
RCD trip-out test (max. nominal differ-
ential current - 30 mA).
Optical and acoustic continuity test.
LED torch lamp.
Automatic switch off.
CAT IV / 1000 V overvoltage protection.
APPLICATION:
Mid level electrical testing;
Mid level electronic fault nding;
Field servicing;
General purpose.
STANDARD SET:
Voltage tester MD 1155
1.5 V battery, type AAA, 2 pcs
Captive test probe protection
Plastic probe guard (in accordance
with GS38)
Instruction manual
Warranty
TECHNICAL SPECIFICATION:
Function Range
Nominal voltage range 3 V 1000 V AC TRMS (automatic range selection)
Nominal voltage range 4 V 1400 V DC (automatic range selection)
Frequency range 0 1000 Hz
Resistance range 0 2 k
RCD test current 30 mA
Phase indication >100 VAC
Phase rotation determination 100 V 1000 V, 2-pole
Reaction time < 0.1 s
Display 3-1/2 digit LCD display with backlight
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 1000 V
Dimensions 300 x 75 x 20 mm
Weight 270 g
VOLTAGE AND CONTINUITY TESTERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 28 7. 29 Accessories: page 7.30 Accessories: page 7.30
TECHNICAL SPECIFICATION:
The MD 1055 is a multifunction voltage / continuity tester. Because of its broad spectrum of measurement functions, it is
suitable for use both in the home and in trade and industrial sectors.
MEASURING FUNCTIONS:
AC, DC voltage testing;
Phase testing;
Rotary eld testing;
Continuity testing;
RCD trip-out test.
KEY FEATURES:
6 V 1000 V AC voltage range.
6 V 1400 V DC voltage range.
Phase rotation measurement.
RCD trip-out test (max. nominal differ-
ential current - 30 mA).
Optical and acoustic continuity test.
LED torch lamp.
CAT IV / 1000 V overvoltage protection.
APPLICATION:
General purpose;
Electrical testing.
STANDARD SET:
Voltage tester MD 1055
1.5 V battery, type AAA, 2 pcs
Captive test probe protection
Plastic probe guard (in accordance with
GS38)
Instruction manual
Warranty
MD 1055 LED Voltage / Continuity Tester
Function Range
Display
16 red LEDs for voltage, continuity,
polarity and phase rotation measurement
Nominal voltage range
12 V, 24 V, 48 V, 120 V, 230 V, 400 V, 690 V, 1000 V
(automatic range selection)
Frequency range 0 1000 Hz
Resistance range 0 50 k
RCD test current 30 mA
Phase indication >100 VAC
Phase rotation determination 100 V 1000 V, 2-pole
Reaction time < 0.1 s
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 1000 V
Dimensions 300 x 75 x 20 mm
Weight 270 g
VOLTAGE AND CONTINUITY TESTERS
MD 115 Non Contact Voltage Detector MD 105 Non Contact Voltage Detector
The MD 115 is a non-contact voltage tester that features a
visual display, vibrating indicator and comes complete with
a pocket clip. It is easy to operate and can be used for a
wide variety of jobs; this is an essential tool for both home
handymen and professionals. The tester can detect an in-
visible break within an extension cable with an accuracy of
just a few millimeters. A defective bulb in a chain of lights
can be located within seconds. Live-voltage wires (e.g., in
cable plugs, cable drums, sockets, switches and junction
boxes) can also be quickly detected.
The MD 105 is a basic non-contact voltage tester that fea-
tures a visual display indicator and comes complete with a
pocket clip. The contact-less MD 105 voltage tester can, for
example, detect live wires in splices, cable drums, socket
outlets and switches. A defective lamp in a chain of lights
can be localized within seconds. An invisible cable break-
age in an extension lead is indicated to within a tolerance
of just a few millimeters. The Metrel MD 105 uses a capaci-
tive measuring process. In contrast to inductive measure-
ments, no flow of current is required.
MEASURING FUNCTIONS:
Non contact voltage detection from 12 V AC;
High performance LED ashlight;
Vibration alert in case of power.
KEY FEATURES:
12 V 1000 V AC measurement range;
Optical and vibrating indication;
CAT III / 1000 V overvoltage protection.
APPLICATION:
General purpose;
Low level electrical testing;
Hobby work.
STANDARD SET:
Non Contact Voltage Detector MD 115
1,5 V battery test, type AAA, 2 pcs
Instruction manual
Warranty
MEASURING FUNCTIONS:
Non contact voltage detection from 110 V AC;
KEY FEATURES:
110 V 1000 V AC measurement range;
CAT III / 1000 V overvoltage protection.
APPLICATION:
General purpose;
Low level electrical testing;
Hobby work.
STANDARD SET:
Non Contact Voltage Detector MD 105
1,5 V battery test, type AAA, 2 pcs
Instruction manual
Warranty
Function Range
Display Visual, vibration
Measurement range 12 1000 V AC
Integrated LED ash light Yes
Power supply 2 x 1,5 V batteries, type AAA
Overvoltage category CAT III / 1000 V
Degree of protection IP 40
Dimensions 160 x 25 mm
Weight 45 g
TECHNICAL SPECIFICATION: TECHNICAL SPECIFICATION:
Function Range
Display Visual
Measurement range 110 1000 V AC
Integrated LED ash light Yes
Power supply 2 x 1,5 V batteries, type AAA
Overvoltage category CAT III / 1000 V
Degree of protection IP 44
Dimensions 142 x 26 mm
Weight 22 g
NON CONTACT VOLTAGE DETECTORS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
7. 30 Accessories: page 7.30
Photo
Part
number
Description Target application
M
D

9
0
6
0
M
D

9
0
5
0
M
D

9
0
4
0
M
D

9
2
3
5
M
D

9
0
3
0
M
D

9
0
2
0
M
D

9
0
1
6
M
D

9
0
1
5
M
D

9
2
5
0
M
D

9
2
3
5
M
D

1
1
5
5
M
D

1
0
5
5
AMD
9023
Thermocouple probe,
type K
Probe for contact temperature measurement.
AMD
9024
Adapter for
thermocouple probe
AMD 9023
Adapter is intended to connect the thermocouple
probe with a multimeter.

AMD
9025
PC Software for MD
9015 with RS232
cable
Basic downloading software supplied on CD and
RS232 communication cable.

AMD
9050
USB interface set
Communication set contains USB adapter, USB and
RS232 drivers and PC software on CD.

AMD
9240
PC interface set for
MD 9240
PC interface set enables data transferring to the PC.
Set contains optical adapter, cable and PC software
on CD.

AMD
9250
PC interface set for
MD 9250
PC interface set enables data transferring to the PC.
Set contains optical adapter, cable and PC software
on CD.

AMD
1100
Soft carrying bag Small soft bag for storage of the multitester.
AMD
9022
Magnetic Hanging
Strap
The universal hanger allows you to hang your meter
on metal surfaces.

Selection Guide for DMM Accessories
GOOD TO KNOW
Variable transformers 8 - 02
VARIABLE TRANSFORMERS
Single-phase Built-in Variable Transformers 8 - 04
Three-phase Built-in Variable Transformers 8 - 04
Motor driven Variable Transformers 8 - 04
Desk top Variable Transformers 8 - 05
EQUIPMENT FOR LABORATORIES AND SCHOOLS
Power Supplies 8 - 05
R-L-C Decade 8 - 05
V
a
r
i
a
b
l
e

t
r
a
n
s
f
o
r
m
e
r
s

/

E
q
u
i
p
m
e
n
t

f
o
r

l
a
b
o
r
a
t
o
r
i
e
s

a
n
d

S
c
h
o
o
l
s
P
o
w
e
r

s
u
p
p
l
i
e
s
,

L
a
b
o
r
a
t
o
r
y

a
n
d

t
e
s
t

e
q
u
i
p
m
e
n
t
,

V
o
l
t
a
g
e

s
t
a
b
i
l
i
z
e
r
s
,

H
i
g
h

v
o
l
t
a
g
e

t
e
s
t

s
e
t
,

H
y
d
r
o

g
e
n
e
r
a
t
i
o
n

p
l
a
n
t
s
,

e
t
c
.
MEASURING INSTRUMENTS AND TESTERS
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certication
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
CATALOGUE 2014
Variable transformers /
Equipment for laboratories and Schools
Option Not available
Variable transformers / Equipment for laboratories and Schools Variable transformers / Equipment for laboratories and Schools
8. 2 8. 3
Variable transformers Variable transformers
GOOD TO KNOW GOOD TO KNOW
METREL is well known producer of
variable transformers and power sup-
plies which are widely accepted in
laboratories, industry, schools.
The competitiveness of these products
is based on a good price/performance
ratio. They are robust in construction,
they have low magnetizing current, low
operating torque and no distortion or har-
monics added. Copper winding is preci-
sion wound on a toroidal core. Tradition
with 50 years of experience in continu-
ous production, product control, testing,
safety, permanent improvements and,
customer service are l rouge in the pro-
duction of METREL variable transform-
ers. Complete information on variable
transformers and complete instrument
product groups of METREL can be found
on www.metrel.si.
METREL variable transformers are avail-
able as:
Single or poly phase types;
Autotransformer or insulated variable
transformer;
Manual or motor driven variable trans-
former;
Open / panel mount or enclosed con-
struction;
Air-cooled, optional oil-cooled variable
transformer.
METREL variable transformers provide
continuously adjustable voltage from
zero to 100% or 113% of the line volt-
age. Their operation is simple and ef-
cient. Cooper wire is wound on a toroi-
dal core by using high precision winding
machines. Sliding trace of the winding
is properly smoothed to provide low re-
sistance and long wearing track for the
carbon brush. Some models are silver
plated, providing lower output imped-
ance. The core is made of strip-wound
oriented silicon steel for low electrical
losses and high magnetic densities. The
coil is insulated from the core by means
of a special insulation support that also
prevents movement of coil turns. Varia-
ble transformers are wound in a manner
to ensure that voltage between the two
turns is small enough to avoid harmful
sparking or excessive heating of shorted
turns.
0.1 1 10 100 1000 t (min)
100
200
300
400
500
In (%) 600
Standard track
Silvered track
Short duration loading
20 30 40 50 60 70 80 100
20
40
80
100
120
60
90 Ta C ( )
In (%)
Loading versus ambient temperature
Standard track
Silvered track
20 40 60 80 120Uo/Uin % ( )
20
40
80
100
60
Udn (%)
100
120
Normalized voltage drop Uo
o
METREL variable transformers provide
an output voltage waveform that is a
precise reproduction of the applied input
voltage waveform. Slider is mounted on
shaft but electrically insulated from it.
With a brush holder, it serves also as a
heat sink. Only standard METREL vari-
able transformers are listed in this cata-
logue.
Technical regulation
Three general regulations serve as a
base for function, quality and safety of
METREL variable transformers: Euro-
pean Low voltage directive 2006/95/
EC (72/23/EEC), German standard VDE
0552 and International standard IEC
60989.
Applications
METREL variable transformers are ap-
plied to various products or applications
including the following:
Power supplies;
Laboratory and test equipment;
Speed control devices;
Computer peripheral equipment;
Welding controls;
Variable speed devices for large ma-
chinery;
Electroplating and anodising;
High-voltage electronic tube circuits;
Spare supply regulators in broadcast
transmitters;
Voltage stabilizers;
High voltage test set;
Meter test bench;
Hydro generation plants;
Battery chargers;
DC motor controls;
Plastic blow moulding machines;
Control of furnace transformers;
Lightening regulation;
Laboratory stirrers;
AC, DC brush motors;
High current motorized voltage regula-
tors;
High current plastic plating operations.
TECHNICAL PERFORMANCES:
High reliability
METREL variable transformers are prac-
tically maintenance free. Long-life opera-
tion is assured with:
Precision winding;
Surface forming of winding;
Tight tolerances in preparing sliding
track;
Deep varnishing and baking also for x-
ing winding structure;
A spring-loaded solid carbon brush.
Power factor
Power factor of load has very little effect
on the operation of a METREL variable
transformer in the range from 0.5 lag-
ging to 0.5 leading. Like any transform-
er, the METREL variable transformer
reects the load power factor to the line
with very little change. Only for very light
loads, possibly under 10%, will the lag-
ging power factor of the METREL vari-
able transformer become signicant due
to magnetizing current.
High efciency
METREL variable transformers have
low electrical losses under all load con-
ditions. Efciency is 98.5 percent at
maximum output voltage selected. This
efciency remains high, even at greatly
reduced load voltage.
Ambient temperature
METREL variable transformers are de-
signed for continuous operation in ambi-
ent of 0 C to 40 C, at full rated load.
When operated above 40 C, the output
power must be derated in accordance
with diagram 1. For example, when op-
erating model HSH 230/4 in a 60 C am-
bient, rated output current would be: 70
% x 4 A = 2.8 A.
0.1 1 10 100 1000 t (min)
100
200
300
400
500
In (%) 600
Standard track
Silvered track
Short duration loading
20 30 40 50 60 70 80 100
20
40
80
100
120
60
90 Ta C ( )
In (%)
Loading versus ambient temperature
Standard track
Silvered track
20 40 60 80 120Uo/Uin % ( )
20
40
80
100
60
Udn (%)
100
120
Normalized voltage drop Uo
o
Frequency
All METREL variable transformers are
designed for operation at 50/60 Hz. They
may be operated at higher frequencies,
without derating, however regulation
becomes poorer. Units listed for 230 V
operations may be applied on 115 V at
25 Hz, however rated currents remain
the same.
Linear output voltage
METREL variable transformers have the
advantage of providing output voltage
that varies linearly in proportion to the
angle of rotation of the output voltage
selector. Because of the large number
of increments of output voltage selec-
tion with the slider, the output voltage is
practically steeples.
0.1 1 10 100 1000 t (min)
100
200
300
400
500
In (%) 600
Standard track
Silvered track
Short duration loading
20 30 40 50 60 70 80 100
20
40
80
100
120
60
90 Ta C ( )
In (%)
Loading versus ambient temperature
Standard track
Silvered track
20 40 60 80 120Uo/Uin % ( )
20
40
80
100
60
Udn (%)
100
120
Normalized voltage drop Uo
o
Uo/Uo max for autotransformer / Uo max = Uin
Uo/Uo max for autotransformer / Uo max > Uin
Uo/Uo (at Uo = Uin) for separate secondary
Uo/Uo for separate secondary
Uo/Uo for autotransformer / Uo max = Uin
Uo/Uo for autotransformer / Uo max > Uin
Installation guidelines
For safety and reliable operation of MET-
REL variable transformers the following
requirements need to be fullled:
good venting;
appropriate wiring;
over current protection;
avoiding corrosive, high humidity and
dust places or protection against these
environmental conditions;
preventing short circuits on axis;
appropriate design and construction of
equipment with built-in variable trans-
formers.
Venting of power devices reduces their
heating and thus rated performances
can be applied. Power lines must have
high enough cross-section, be xed
and secured with good contact to pre-
vent overheating and additional voltage
drops. Primary overcurrent breaking
device must be properly selected and
use of load protection fuses is recom-
mended. Fuses / residual circuit break-
ers (RCD) prevent excessive heating due
to overload and prevent re generation
as a result of overheating.
Regardless if the variable transformers
are designed for harsh environment, it
is best for reliable operation and long
lifetime to keep them in non-aggressive
environment. The axis is on one side
connected to metal base. If the other
side of axis is electrically connected to
the same base (through the housing),
this will present a short circuit coil of the
transformer with increasing power con-
sumption, overheating, and even gen-
erating high leakage currents and stray
magnetic elds.
It is important that the brushes are not
leaving in one spot for extended peri-
ods to avoid gradually increase contact
resistance and eventual overheating and
damage of the variable transformer unit.
OPTIONS:
Parallel connections
METREL has a solution for paralleling
two single-phase transformers. Output
current can be doubled by using the bal-
ancing choke and mechanical paralleling
of sliders on common shaft.
Serial connections
Serial connection is intended for appli-
cation of variable transformers in instal-
lations with higher input voltage than
rated. Two variable transformers of the
same type are connected in series and
enable operation with double voltage of
rated for one.
Dual voltage tap slides
This possibility enables generating vari-
able differential voltage with the same or
opposite phase related to input voltage.
Typical applications are boosting regula-
tors.
Shaft modications
The shaft provided with each model ac-
commodates the METREL transformers
voltage selector knob when mounted
on panels not exceeding the thickness
shown in dimension data. Modication
to the shaft, either in length or end di-
ameter, is available for both manual and
motor-operated units.
Product groups
a) Open variable transformer types (sub-
assemblies for panel mount or other
built-in equipment) HSG; HST; HTG;
HSM; HTM with Accessories (Buttons,
Scales, Motor drives).
b) Desk top variable transformer types
(HSN, HTN).
c) Power supplies (MA 4804, MA 4852,
MA 4853).
Technical specication
Frequency range: 50 Hz 400 Hz
Mechanical angle:
340, core size up to M200
320, other core sizes
Protection class: I
Pollution degree: 2
Protection degree: IP 20
Altitude (operation): 2000 m
Test voltage
(input to metallic
accessible parts):
2500 VAC RMS, 50 Hz, 2 s
Test voltage
(input/output, HST):
4000 VAC RMS, 50 Hz, 2 s
Operating temperature
range:
-5 C 40C
Operating humidity
range:
90 % RH (40 C),
non-condensing
Storage temperature
range:
-15 C 70 C
Variable transformers / Equipment for laboratories and Schools Variable transformers / Equipment for laboratories and Schools
8. 4 8. 5
Motor driven 3-phase Built-in 1-phase Built-in Desk top Power Supplies R-L-C Decade
HSG - Autotransformers
The HSG series voltage transformers
are often built in test equipment or per-
manent installations. Output voltage is
controlled with a large, slip-protected
knob. Output voltage is increased lin-
early as the knob is turned clockwise.
The user is required to add adequate
external over-current protection device
like fuse or circuit breaker. All models
are suitable for 50 Hz / 60 Hz frequency
range. Single- and three-phase models
are available with various current ratings.
Output voltage is precisely controlled.
Autotransformer design allows optional
voltage boost. Because of demanding
applications all Metrel variacs are de-
signed to exhibit superior resistance
to high temperature, humidity and me-
chanical shocks/vibrations. Used in hard-
wired, permanent installations wherever
operational or performance points need
to be varied.
Technical specication
1-phase: HSG 230 HSG 260
Input voltage: 230 V 230 V
Output voltage: 0 V 230 V 0 V 260 V
Current:* 1 A 32 A 0.8 A 30 A
Power: 230 VA 7360 VA 208 VA 7800 VA
* Maximum current range depends on model type
HST - Separating transformers
Variable, coupled with insulation trans-
formers are utilized for personnel safety
in addition to provide variable voltages
for testing purposes. In general they are
equally suitable for any of the testing,
engineering or control function like or-
dinary variacs based on autotransformer
design. Additionally they can isolate sen-
sitive equipment from interference and
ground noise.
HTG - Autotransformers
METREL three-phase transformers are
suitable for connection to either delta or
star connected incoming power sources
or loads. They are always star connected
and have a neutral connection accessi-
ble. A common shaft rotates all output
voltage sliders in parallel.

3-phase METREL transformers with
3-wire connection to 3-phase supply sys-
tem can be used to feed 3-wire, 3-phase
balanced loads. In this case the common
connection (or virtual neutral) of the
METREL unit should not be used. Less
than 10% of rated current of variable
transformers owing into virtual neutral
would keep unbalance of three-phase
output in reasonable limits.
With a three phase, 4-wire system in-
put, the system neutral should be solidly
connected to the common or neutral
point of the METREL unit. This will pre-
vent neutral shift and possible damage
or failure of the unit. Full-range voltage
control cannot be obtained from a three-
phase METREL unit consisting of three
single-phase units connected in closed
delta. Outside the factory, it is not prac-
tical to convert multiple single-phase
models to balanced three-phase applica-
tions because of associated mechanical
problems.
Technical specication
3-phase: HTG 400 HTG 450
Input voltage: 400 V 400 V
Output voltage: 0 V 400 V 0 V 450 V
Current:* 1 A 32 A 0.8 A 30 A
Power: 690 VA 22080 VA 624 VA 23400 VA
* Maximum current range depends on model type
HSM 1-phase and HTM 3-phase
METREL motor-operated units dif-
fer from manual types primarily in the
means used to rotate the shaft to vary
output voltage. A synchronous motor is
used to position the slider. The motor is
reversible by means of a SPDT switch
(not supplied) and operates on 230 V, 50
/ 60 Hz. Integrated limit switches pre-
vent overriding the winding edges.
Typical methods for controlling METREL
motor-operated units include:
Manual increase/decrease switch con-
sists of either momentary-contact push-
button or lever-type toggle switch.
Relays and contactors control the in-
crease/decrease power to the motor as
a result of low-level signals from external
circuitry. Example: photoelectric cells or
thermostat signals can provide the input.
Process control instrumentation can
be used for closed-loop, precise con-
trol, and more sophisticated circuitry to
provide the raise-fall switching for the
motor.
Motor operating time refers to the num-
ber of seconds for the motor to traverse
its full range in one direction. METREL
transformers have standard 23 s motor
operating time. Other motor operating
times are optional.
Technical specication
1-phase: HSM230 HSM260
Input voltage: 230 V 230 V
Output voltage: 0 V 230 V 0 V 260 V
Current:* 3 A 32 A 2.5 A 30 A
Power: 690 VA 7360 VA 650 VA 7800 VA
3-phase: HTM400 HTM450
Input voltage: 400 V 400 V
Output voltage: 0 V 400 V 0 V 450 V
Current:* 3 A 32 A 2.5 A 30 A
Power: 2070 VA 22080 VA 1930 VA 23400 VA
* Maximum current range depends on model type
HSN 1-phase and HTN 3-phase
The HSN and HTN series voltage trans-
formers are fully housed, thus providing
protection from physical accidents, and
other hazards. Generally they are used
wherever adjustable AC voltage is re-
quired. Output voltage is precisely con-
trolled.
Output voltage is controlled with a
large, slip-protected knob. Output volt-
age is increased linearly as the knob
is turned clockwise. All models are
equipped with power cord, illuminated
on/off switch and external PE terminal
and optional with appropriate plug con-
nector. They are marked with output
voltage in volts (corresponding to nomi-
nal input voltage).
They can be conveniently moved
around laboratory, production or equip-
ment service area to provide adjustable
voltage.
All models are suitable for 50 Hz / 60
Hz frequency range. Single- and three-
phase models are available with various
current ratings.
Technical specication
1-phase: HSN 260
Input voltage: 230 V
Output voltage: 0 V 260 V
Current:* 4.5 A 30 A
Power: 1170 VA 7800 VA
3-phase: HTN 450
Input voltage: 400 V
Output voltage: 0 V 450 V
Current:* 8 A 30 A
Power: 6240 VA 23400 VA
* Maximum current range depends on model type
MA 4804, MA 4852 and MA 4853
The MA 4804, MA 4852 and MA 4853
are power supply units with the built-in
variable transformers permiting a con-
tinuous voltage adjustment within the
limits of declared specications.
The transformers have separate primary
and secondary windings resulting in gal-
vanic isolation of the mains circuit from
output circuit. This is frequent require-
ment for energizing specic electrical
devices.
The power supply units are equipped
with V-meter and A-meter, which allow
a permanent control over output voltage
and current. They are overload-protected
with a circuit-breaker which disconnects
the secondary circuits when a short-cir-
cuit condition occurs at the output.
Field Application
The MA 4804, MA 4852 and MA 4853
power supply units are used in electron-
ic industry (electrical and control labs), in
service workshops, in technical educa-
tion, etc., briey everywhere adjustable
supply voltage is needed, or where for
technical or safety reasons the power
supply source has to be galvanically in-
sulated from the mains. Test voltage of
4 kV AC. rms between input and output
enables using the units in CAT III / 300 V
environment.
Technical specication
Part No. HSM230 HSM260 HSM260
Power supply: 230 V 230 V 230 V
Output voltage:
AC
DC
0 V 260 V 0 V 33 V
0 V 46 V
0 V 33 V
0 V 46 V
Permissible
permanent
current:
3.1 A 6 A 6 A
* Maximum current range depends on model type
MA 2405, MA 2705 and MA 2115
MA 2405 Decade capacitor is intended
for all application areas where capaci-
tance variation/selection by hand is re-
quired. It is all passive electric device
housed in metallic case and with internal
guarding. It consists of 3 decades for
selection of the capacitance in range of
100 pF up to 100 nF. Set value is directly
visible on decades dials. MA 2405 Dec-
ade Capacitor uses high quality polypro-
pylene capacitors providing accuracy of
5 %.Very good DC insulation resistance
of the capacitors enables the application
also in DC circuits, insulation materials
also provide low dissipation factor at the
frequencies of 500 kHz and up.
MA 2705 Decade inductance is in-
tended for all application areas where
inductance variation/selection by hand
is required. It is passive electric device
housed in metallic case. It consists of
3 decades for selection of the induct-
ance in range of 0 mH up to 999 mH.Set
value is directly visible on decades dials.
MA 2705 Decade inductance uses fer-
rite chokes providing accuracy of 5 % at
50% of rated current.
MA 2115 and MA 2115 S Decade resis-
tors are intended for all application areas
where resistances variation/selection by
hand are required. It is passive electric
device housed in metallic case. Each
consist of 7 decades with each own ro-
tary switch with range multiplier from 0
to 9, and . Safety 4 mm sockets are
connected to each resistance chain that
it could be individually accessible. It is
also possible to split resistance chain
into two or more independent insulated
groups by selection of rotary switch po-
sition .
VARIABLE TRANSFORMERS EQUIPMENT FOR LABORATORIES AND SCHOOLS
GENERAL_2014_Ang_March
Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery.
Subject to technical change without notice.
Metrel d.d.
Measuring and Regulation Equipment Manufacturer
Ljubljanska 77, SI-1354 Horjul
Tel: +386 (0)1 75 58 200; Fax: +386 (0)1 75 49 226
E-mail: metrelmetrel.si; http://www.metrel.si
Metrel GmbH
Metrel Mess- und Prftechnik GmbH
Orchideenstrae 24, 90542 Eckental
Tel.: +49 9126 28996-0; Fax: +49 9126 28996-20
E-mail: metrelmetrel.de; http://www.metrel.de
Metrel UK Ltd.
Test and Measuring Equipment
Unit 1, Hopton House, Ripley Drive, Normanton, West Yorkshire, WF6 1QT
Tel.: +44 (0) 1924 245 000
E-mail: infometrel.co.uk; http://www.metrel.co.uk

You might also like