The document discusses Controller Area Network (CAN) systems in trucks and buses based on the SAE J1939 specification. It describes the key characteristics including the OSI network layers used, with J1939 specifications applied to the physical, data link and application layers. The 29-bit message identifier format is explained, covering priority, parameter/source address fields. Message types are outlined for information sharing, commands, requests, diagnostics and more.
The document discusses Controller Area Network (CAN) systems in trucks and buses based on the SAE J1939 specification. It describes the key characteristics including the OSI network layers used, with J1939 specifications applied to the physical, data link and application layers. The 29-bit message identifier format is explained, covering priority, parameter/source address fields. Message types are outlined for information sharing, commands, requests, diagnostics and more.
The document discusses Controller Area Network (CAN) systems in trucks and buses based on the SAE J1939 specification. It describes the key characteristics including the OSI network layers used, with J1939 specifications applied to the physical, data link and application layers. The 29-bit message identifier format is explained, covering priority, parameter/source address fields. Message types are outlined for information sharing, commands, requests, diagnostics and more.
The document discusses Controller Area Network (CAN) systems in trucks and buses based on the SAE J1939 specification. It describes the key characteristics including the OSI network layers used, with J1939 specifications applied to the physical, data link and application layers. The 29-bit message identifier format is explained, covering priority, parameter/source address fields. Message types are outlined for information sharing, commands, requests, diagnostics and more.
The key takeaways are that SAE J1939 defines standards for networks in commercial vehicles to allow components from different manufacturers to communicate. It uses the CAN bus protocol with extended frames and defines standards for the physical, data link and application layers.
The main characteristics of SAE J1939 networks are that they use CAN as the data link layer protocol with extended frames, define standards for message formats, parameter and diagnostic codes, and support various message types like requests, commands, and acknowledgments.
The OSI network layer model applies to SAE J1939 with the physical layer defining electrical specifications, the data link layer using CAN with extended frames, and the application layer defining standards for parameters, diagnostics, and other application data.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 1/39
KATHO department VHTI Industrial Sciences and Technology
study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
1 INTRODUCTION...................................................................................................................................... 2 2 MAIN CHARACTERISTICS................................................................................................................. 3 3 OSI NETWORK LAYER MODEL....................................................................................................... 5 4 PHYSICAL LAYER................................................................................................................................... 6 5 DATA LINK LAYER SAEJ1939/21 : MESSAGE FORMAT.............................................. 12 5.1 EXTENDED CAN FRAME SAE J1939 ......................................................................................... 13 5.2 29 BITS IDENTIFIER IN DETAIL ........................................................................................................ 14 6 APPLICATION LAYER SAEJ1939/71......................................................................................... 20 6.1 DESCRIPTION OF PARAMETER GROUP NUMBERS (PGN)..................................................................... 20 6.2 DESCRIPTION OF SUSPECT PARAMETER NUMBER (SPN) .................................................................... 21 7 MESSAGE TYPES................................................................................................................................... 23 7.1 MESSAGE TYPE: INFORMATION SHARING BROADCAST OR RESPONSES.......................................... 24 7.2 MESSAGE TYPE: REQUEST ..................................................................................................................... 25 7.3 MESSAGE TYPE: COMMAND.................................................................................................................... 26 7.4 MESSAGE TYPE: ACKNOWLEDGMENT (ACK)......................................................................................... 27 7.5 MESSAGE TYPE: PROPRIETARY MESSAGES (GROUP FUNCTION) ............................................... 28 7.6 MESSAGE TYPE: MULTI-PACKET TRANSPORT FUNCTIONS - LONG MESSAGES (GROUP FUNCTION) . 29 7.6.1 Multipacket Broadcast (Broadcast Transmission Protocol) .................................... 30 7.6.2 Multipacket Destination Specific. ........................................................................................ 31 8 APPLICATION LAYER SAE J1939/73 : DIAGNOSTICS................................................... 33 8.1 DIAGNOSTIC MESSAGES (DM) .............................................................................................................. 33 8.2 DM 1(DIAGNOSTIC MESSAGE 1) ACTIVE DIAGNOSTIC TROUBLE CODES ........................................ 34 8.3 DATA FIELDS OF A DM1 MESSAGE ........................................................................................... 35 8.4 FMI FAILURE MODE INDICATION............................................................................................... 36 9 NETWORK MANAGEMENT ............................................................................................................... 37 9.1 NETWORK ADRESSES AND NAMES......................................................................................................... 37 9.2 SAE J1939 INDUSTRY GROUPS PREFERRED NETWORK ADDRESSES ......................................... 38 9.3 PROCEDURE ADDRESS CLAIMING..................................................................................................... 39
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 2/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
1 INTRODUCTION
CAN-SAEJ 1939 networks DAF Trucks
In the early 90ties, the SAE (Society of Automotive Engineers) Truck and Bus Control and Communications Sub- committee started the development of a CAN-based application profile for in-vehicle communication in trucks. In 1998 the SAE published the J 1939 set of specifications supporting SAE class A, B, and C communication functions. A J 1939 network connects electronic control units (ECU) within a truck and trailer system. The J 1939 specification - with its engine, transmission, and brake message definitions - is dedicated to diesel engine applications. It is supposed to replace J1587/J1708 networks.
Other industries adopted the general J 1939 communication functions, in particular the J 1939/21 and J 1939/31 protocol definitions - they are required for any J 1939-compatible system. They added other physical layers and they defined other application parameters. The ISO standardized the J 1939-based truck and trailer communication (ISO 11992) and the J 1939-based communication for agriculture and forestry vehicles (ISO 11783). The NMEA specified the J 1939-based communication for navigation systems in marine applications (NMEA 2000). One reason for the incorporation of J 1939 specifications into others is the fact that it makes sense to re-invent the basic communication services. An industry-specific document defines the particular combination of layers for that industry.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 3/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
DATA LINK LAYER - APPLICATION LAYER 29-bit identifier: Priority Identification data (PGN), ( +some cases destination address) Source address 8 data bytes (SPN) Sharing information (vehicle data) Commands Configuration Diagnostics PHYSICAL LAYER 250 kbps Twisted pair End line resistors 2x120 ohm
2 MAIN CHARACTERISTICS
TRUCKS, BUSSES, OFF-ROAD- EN AGRICULTURE VEHICLES
ID 11 BITS ID18 BITS DATA 8 BYTES NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 4/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
3 OSI NETWORK LAYER MODEL
1. Physical - Concerns the transmission of structured bit stream over physical media; deals with the mechanical, electrical, functional, and procedural characteristics to access the physical media 2. Data Link - Provides the reliable transfer of information across the physical layer; sends blocks of data (frames) with the necessary synchronization, error control, sequence control, and flow control; 3. Network - Provides upper layers with independence from the data transmission and switching technologies used to connect systems; responsible for establishing, maintaining, and terminating connections; 4. Transport - Provides reliable, transparent transfer of data between end points; provides end-to-end error recovery and flow control; provides segmentation and reassembly of very large messages; 5. Session - Provides the control structure for communication between applications; establishes, manages, and terminates connections (sessions) between cooperating applications; 6. Presentation - Provide independence to the application process from differences in data representation. 7. Application - Provides access to the OSI environment for users and also provides distributed information services.
J 1939/11 - 15 J 1939/21 J 1939/31 J 1939/21 not defined not defined J 1939/71 J 1939/73 DATA LINK NETWORK TRANSPORT SESSION PRESENTATION APPLICATION
PHYSICAL 29 bits IDENTIFIER - Based on CAN ISO11898 ISO 11898 HSCAN - 250 kbps - 2x120 ohm /71: vehicle data-commands-configuration /73: diagnostics BUS NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 6/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
4 PHYSICAL LAYER
SAE J 1939/11 - /15. describes the physical layer: Bit rate 250 kbps Shielded or unshielded twisted pair cable End of line resistors Bus levels (bit encoding/decoding) Synchronisation Bus characteristics (cables and connectors) Number of module Bus length
Physical layer Data link layer NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 7/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
BUSLEVELS TERMINATION RESISTORS
120 ohm 120 ohm
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 8/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
CANL 2,5 - 1,5 V CANH 2,5 - 3,5 V NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 9/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 10/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
Network wiring topology
R L : end line resistors Bus length L: max 40 m Cable stub S: max 1 m Node distance d: min 0,1 , max 40 m Cable stub for diagnostic connector: max 0,66 m on the vehicle +0,33 m for the off board tool
The wiring topology of this network should be as close as possible to a linear structure in order to avoid cable reflections. In practice, it may be necessary to connect short cable stubs to a main backbone cable. To minimize standing waves, nodes should not be equally spaced on the network and cable stub lengths, dimension S, should not all be the same length.
ECU 1 ECU 2 ECU 3 ECU 4 R L R L
d S L NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 11/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
Busfailure
Open and Short Failures- In principle, failures are detectable if there is a significant message destruction rate, as interpreted by the electronic control units. Some external events that may cause failures are shown a. Case 1: CAN-H is Interrupted-Data communication between nodes on opposite sides of an interruption is not possible. Data communication between nodes on the same side of an interruption may be possible, but with reduced signal-to-noise ratio. b. Case 2: CAN-L is Interrupted-Data communication between nodes on opposite sides of an interruption is not possible. Data communication between nodes on the same side of an interruption may be possible, but with reduced signal-to-noise ratio. c. Case 3: CAN-H is Shorted to VBat-Data communication is not possible if VBat is greater than the maximum allowed common mode bus voltage. d. Case 4: CAN-L is Shorted to GND-Data communication is possible, because the bus voltages are within the allowed common mode voltage range. Signal-to-noise ratio is reduced and radiation is increased. The electromagnetic immunity is decreased. e. Case 5: CAN-H is Shorted to GND-Data communication is not possible. f. Case 6: CAN-L is Shorted to VBat-Data communication is not possible. g. Case 7: CAN-H is Shorted to CAN-L--Data communication is not possible. h. Case 8: Both Bus Lines are Interrupted at the Same Location-Data communication between nodes on opposite sides of an interruption is not possible. Data communication between nodes on the same side of an interruption may be possible, but with reduced signal-to-noise ratio. i. Case 9: Loss of Termination Resistor- Data communication via the bus may be possible, but with reduced signal-to-noise ratio. J ; Case 10: Topology Parameter Violation (i.e. , Bus Length, Cable Stub Length, Node Distribution) Data communication via the bus may be possible, but with reduced signal-to-noise ratio.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 12/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
5 DATA LINK LAYER SAEJ1939/21 : MESSAGE FORMAT
The data link layer provides for the reliable transfer of data across the physical link. This consists of sending the CAN Data Frame with the necessary synchronization, sequence control, error control, and flow control. The flow control is accomplished by a consistent message/frame format.
The data link layer services are implemented in the Logical Link Control (LLC) and Medium Access Control (MAC) sub-layers of a CAN controller.
The LLC provides acceptance filtering, overload notification and recovery management.
The MAC is responsible for data encapsulation (de-capsulation), frame coding (stuffing/de-stuffing), medium access management, error detection, error signalling, acknowledgement, and serialization (de-serialization).
Physical layer Data link layer NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 13/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
5.1 EXTENDED CAN FRAME SAE J1939
Message format conforms to the CAN requirements. The CAN specification referenced throughout this document is CAN Specification 2.0 Part B, September 1991. It should be noted that when there are differences between the CAN specification and SAE J 1939, then SAE J 1939 is the guiding document. The CAN document specifies, in an information routing related discussion, that node addresses are not used. While this is true for some applications of CAN, it is not true for SAE J 1939. The definition of the SAE J 1939 network requires that node addressing be used to prevent multiple nodes from using the same CAN Identifier field (see SAE J1939). Many additional requirements exist in SAE J 1939 that are not specified by CAN.
CAN 2.0B contains specification of two message formats, standard frame and extended frame. CAN 2.0B compatibility implies that messages of both formats can potentially be present on a single network by using certain bit coding that allow for the recognition of the different formats. To this point, SAE J 1939 also has accommodations for both CAN data frame formats. But SAE J 1939 only defines a full strategy for standardized communications using the extended frame format. AII standard frame format messages are for proprietary use following the rules defined in this document. Therefore, SAE J 1939 devices MUST use the extended frame format. Standard frame format messages can reside on the network, but only as described in this document.
NOTE Standard frame devices do not respond to network management messages and are not able to support the strategy for standardized communications. The CAN data frame is parsed into different bit fields. The number and parsing of the bits in the arbitration and control fields differ between the CAN standard and extended frame messages. CAN standard frame messages, shown in "A," contains 11 identifier bits in the arbitration field and CAN extended frame messages, shown in "B," contain 29 identifier bits in the arbitration field. SAE J 1939 has further defined the identifier bits in the arbitration field of the CAN Data Frame formats.
11 BITS ID 18 BITS ID DLC DATA CRC EOF SOF SRR IDE RTR R1 R0 ACK 3 1 1 6 2 8 8 =SAE J 1939 PGN SOURCE address 29 bits IDENTIFIER destination NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 14/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
5.2 29 BITS IDENTIFIER IN DETAIL
J 1939 messages are sent using the CAN Extended Frame. A J 1939 message consists of the following components:
Priority (P) These three bits are used to optimize message latency for transmission onto the bus only. They should be globally masked off by the receiver (ignored). The priority of any message can be set from highest, 0 (000 2 ), to lowest, 7 (111 2 ). The default for all control oriented messages is 3 (011 2 ). The default for all other informational, proprietary, request, and ACK messages is 6 (110 2 ). This permits the priority to be raised or lowered in the future as new PGNs are assigned and bus traffic changes. A recommended priority is assigned to each PGN when it is added to the application layer document. However, the priority field should be reprogrammable to allow for network tuning by the OEM should the need arise.
Reserved Bit (R) This bit is currently reserved for future use by the SAE. This reserved bit should not be confused with the CAN reserved bits. AII messages should set the SAE reserved bit to ZERO on transmit. Future definitions might possibly be expanding the PDU Format field, defining new PDU formats, expanding the priority field, or increasing the address space.
Data Page This 1-bit field defines on which data page (0 or 1) the message is defined in the J 1939 specification. Page 0 contains the messages that are presently defined, while Page 1 is for future expansion.
1 11 2 18 1 1 1 4 0 64 16 2 7 SOF SRR IDE RTR R1 R0 ACK 11 BITS ID 18 BITS ID DLC DATA CRC EOF 11 BITS IDENTIFIER 18 BITS IDENTIFIER S O F D P R I D E S R R R T R PDU SPECIFIC (PS) Destination address (DA), Group extension(GE) SOURCE ADDRESS (PF) cont PDU FORMAT (PF) priority 3 2 1 1 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 bits 8 bits 8 bits PARAMETER GROUP NUMBER NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 15/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
29 bits IDENTIFIER in detail
Protocol Data Unit (PDU) Format (PF)
The PDU Format is an 8-bit field that determines the PDU format and is one of the fields used to determine the Parameter Group Number assigned to the data field. Parameter Group Numbers are used to identify or label commands, data, some requests, acknowledgments, and negative-acknowledgments. Parameter Group Numbers identify or label information that may require one or more CAN Data Frames to communicate the information. If there is more information than fits in 8 data bytes, then a multi-packet message needs to be sent . If there are 8 or less data bytes, then a single CAN data Frame is used. A Parameter Group Number can represent one or more parameters, where a parameter is a piece of data such as engine rpm. Even though a Parameter Group Number label can be used for one parameter, it is recommended that multiple parameters be grouped so that all 8 bytes of the data field are used. The definition of two proprietary Parameter Group Numbers has been established allowing both PDU1 and PDU2 formats to be used. The interpretation of the proprietary information varies by manufacturer. For example even though two different engines may use the same source address, manufacturer "A's" proprietary communications is more likely to be different from manufacturer "B's."
This 8-bit PDU Format field determines the format of the message and is one of the fields that determine the Parameter Group Number of the message (see the Parameter Group Number section).
If the value is between 0 and 239, the message is a PDU 1 Format message. These messages are sent to specific addresses.
If the value is between 240 and 255, the message is a PDU 2 Format message. These messages are not sent to a specific address (CA), but are instead broadcast to the entire network.
PDU Format (PF) PDU Specific PDU1 0-239 Destination address DA PDU2 240-255 Group extension GE
1 11 2 18 1 1 1 4 0 64 16 2 7 SOF SRR IDE RTR R1 R0 ACK 11 BITS ID 18 BITS ID DLC DATA CRC EOF 11 BITS IDENTIFIER 18 BITS S O F D P R I D E S R R R T R PDU SPECIFIC (PS) Destination address (DA), Group extension GE) SOURCE ADDRESS (PF) cont PDU FORMAT (PF) priority 3 2 1 1 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 bits 8 bits 8 bits PARAMETER GROUP NUMBER NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 16/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
29 bits IDENTIFIER in detail
Protocol Data Unit (PDU) Specific (PS) This is an 8-bit field and its definition depends on the PDU format. Depending on the PDU format it can be a Destination Address or a Group Extension. If the value of the PDU Format field is below 240, then the PDU specific field is a destination address. If the value of the PF field is 240 to 255, then the PDU specific field contains a Group Extension value.
Destination Address (DA) This field defines the specific address to which the message is being sent. Note that any other device should ignore this message. The global destination address (255) requires all devices to listen and respond accordingly as message recipients.
Group Extension (GE) The Group Extension field, in conjunction with the four least significant bits of the PDU Format field (note that when the four most significant bits of the PDU Format field are set, it indicates that the PS field is a Group Extension), provides for 4096 Parameter Groups per data page. These 4096 Parameter Groups are only available using the PDU2 format. In addition, 240 Parameter Groups are provided in each data page for use only in the PDU1 format. In total, 8672 Parameter Groups are available to be defined using the two data pages currently available. The total number of Parameter Groups available can be calculated as follows: (240 +(16 x 256)) x 2 =8672
Source Address (SA) The Source Address field is 8 bits long. There shall only be one device on the network with a given source address. Therefore, the source address field assures that the CAN identifier is unique, as required by CAN. Address management and allocation is detailed in SAE J 1939-81. Procedures are defined in SAE J 1939-81 to prevent duplication of source addresses. Reference SAE J 1939 Appendix B, Tables B2 through B9, for source address assignments.
1 11 2 18 1 1 1 4 0 64 16 2 7 SOF SRR IDE RTR R1 R0 ACK 11 BITS ID 18 BITS ID DLC DATA CRC EOF 11 BITS IDENTIFIER 18 BITS S O F D P R I D E
S R R R T R PDU SPECIFIC (PS) Destination address (DA), Group extension GE)
SOURCE ADDRESS (PF) cont PDU FORMAT (PF) priority
3 2 1 1 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 bits 8 bits 8 bits PARAMETER GROUP NUMBER NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 17/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
29 bits IDENTIFIER in detail
Data Field (from 0 to 8 Bytes)
When 8 bytes or less of data are required for expressing a given Parameter Group, then all 8 data bytes of the CAN data frame can be used. It is generally recommended that 8 data bytes be allocated or reserved for all Parameter Group Number assignments which are likely to expand in the future. This provides a means to easily add parameters and not be incompatible with previous revisions that only defined part of the data field. Once the number of data bytes associated with a Parameter Group Number is specified, the number of data bytes cannot be changed (cannot become multi-packet either unless originally defined as multi-packet). The CAN Data Length Code (DLC) is set to the defined Parameter Group "Data Length" value when it is 8 bytes or less; otherwise when the PG Data Length is 9 or greater, the CAN DLC is set to 8. For example the REQUEST PGN, 59904, has the PG Data Length as 3 so the CAN DLC is set to 3. It is important to note that an individual group function Parameter Group (see Section 5.4.5) must use the same length data field because the CAN identifier will be identical while the CAN data field will be used to convey the specific group sub functions, therefore requiring many different interpretations based on the CAN data field.
Data from 9 up to 1785 Bytes When 9 up to 1785 data bytes are needed to express a given Parameter Group, the communication of this data is done in multiple CAN Data Frames. Thus, the term multi-packet is used to describe this type of Parameter Group Number. A Parameter Group defined as multi-packet capable, having fewer than 9 data bytes to transfer in a specific instance, shall be sent in a single CAN Data Frame with the DLC set to 8. When a particular Parameter Group has 9 or more data bytes to transfer, the "Transport Protocol Function" is used. The Transport Protocol Function's Connection Management capability is used to set up and close out the communication of the multi-packet Parameter Groups. The Transport Protocol Data Transfer capability is used to communicate the data itself in a series of CAN Data Frames (packets) containing the packetized data. Additionally, the Transport Protocol Function provides flow control and handshaking capabilities for destination specific transfers.
AII CAN Data Frames associated with a particular multi-packet response are required to have a DLC of 8. AII unused data bytes are set to "not available" (see SAE J 1939-71). The number of bytes per packet is fixed; however, SAE J 1939 defines multi-packet messages that have a variable and/or a fixed number of packets. The Parameter Group Number for active diagnostic codes is an example of a multi-packet message that has a "variable" number of packets. Parameter Groups that are defined as multi-packet only use the transport protocol when the number of data bytes to send exceeds eight.
11 BITS ID 18 BITS ID DLC DATA CRC EOF NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 18/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
11 BIT 19 BIT 000 1 1 0 0 0 1 1 1 1 1 1 1 0 1 0 1 1 1 1 1 1 0 0 0 0 1 0 1 1 1 8 F E B F 0 B NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 19/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
11 BIT 19 BIT 000 1 1 0 0 0 1 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 8 D 5 0 0 F F NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 20/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
6 APPLICATION LAYER SAEJ1939/71
6.1 DESCRIPTION OF PARAMETER GROUP NUMBERS (PGN)
Example: data fields for PGN 61445 ETC2
1 2 3 4 5 6 7 8
Transmission selected gear SPN 524 Transmission actual gear ratio SPN 526 Transmission current gear SPN 523 Transmission requested range SPN 162 Transmission current range SPN 163 NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 21/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
6.2 DESCRIPTION OF SUSPECT PARAMETER NUMBER (SPN)
SPN905 Relative Speed Front Axle Left Wheel
Data Length: 1 byte Resolution: 1/16 km/h /bit Offset: -7,8125 Data Range: -7,8125 to 7,8125 km/h Type: Measured SPN: 905 PGN: 65215
SPN525 - Requested Gear
Data Length: 1 byte Resolution: 1 gear value/bit Offset: -125 Data Range: -125 to 125 Type: Status SPN: 525 PGN: 256
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 22/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
RESOLUTION OFFSET DATA RANGE
Physical value = offset + decimal bit value * resolution
0 to 250 decimal
0 to 15,625 km/h
data range: -7,8125 to 7,8125 km/h
x 1 km/h /bit (=resolution) 16
- 7,8125(=offset) km/h physical value Bit value (decimaal) 0 250 7,8125 - 7,8125 offset NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 23/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7 MESSAGE TYPES
The SAEJ 1939/21 data link layer defines special message types:
Commands, Requests, Broadcasts/Responses, Acknowledgment, and
And, so called Group Functions Proprietary messages Multi-packet messages (transport protocol)
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 24/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.1 MESSAGE TYPE: INFORMATION SHARING BROADCAST OR RESPONSES
Example
Example: Message captured with Vector CANalyzer
Information Sharing Most nodes will have associated with them a set of data which it broadcasts on the network. For example, a generator may transmit data on it loading, fuel consumption, AC amperage and voltage, coolant temperature, and so on. To accomplish this, messages will be defined and PGNs assigned to these messages. All information sharing will be accomplished through these pre-formatted messages. Information sharing messages are generally set at priority 6, unless the committee agrees that the data is particularly time-sensitive (such as data used in mechanical controls). Since each CAN packet can contain eight bytes of data, most messages will include multiple data items. Even if the node does not support every item in the packet, the entire packet is sent. Certain values are used to indicate that a particular datum is not supported or is not available at the moment.
Each node may have several messages associated with it. It is also possible that two nodes may "share" a message each may transmit different data items from the same group. Many data pages may be set to broadcast "on change" rather than on a schedule that is, whenever certain data items change in value. Some may adjust their broadcast frequency according to whether the product is "active". These behaviours must be approved and Documented by the committee when the PGN is defined.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 25/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.2 MESSAGE TYPE: REQUEST
PF =EA hex or 234 dec
DA = global (FF) or specific destination address SA =source address 3 databytes =contain the PGN of the requested information
Example 18 EA FF 27 = Identifier for a request message, send to all, from module 27
18 EA 27 33 =Identifier for a request message, addressed to module 27, from module 33
Information Requests Most messages are broadcast repeatedly at a set rate, but sometimes a node may need to request a datum be transmitted immediately. To accomplish this, a node broadcasts a "Request for PGN" message. All nodes that support that PGN are required to respond to such requests.
A request can be send to all (broadcast), or to a destination specific station.
The Request message for PGN looks like this: PGN: 59904 PDU-F: 234 PDU-S: Destination Address or 255 (Global) Data Length: 3 Priority: 6 Broadcast Rate: As needed Data 1-3: Desired PGN. (LSB First)
If the Destination Address is specific, then the node must respond either with the desired PGN, or if the node does not support the PGN with a Negative Acknowledgment (see further)
Overview: Data page: 0 PDU Format: 234 dec ( EA hex ) PDU specific: Destination Address: global DA=FF hex or specific Default priority: 6 PGN: 59904 (00EA00 16 ) Datafields: D0,D1,D2 requested PGN.
The response on a RQST can be: A CAN frame with maximum 8 bytes A Multi packet data transfer (in case more than 8 data bytes) A NACK (negative acknowledgement), if the requested module is not able to send the requested information.
29 BIT IDENTIFIER DLC DATA Priority PGN SA 3 D0 D1 D2 R DP PF DA requested PGN NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 26/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.3 MESSAGE TYPE: COMMAND
Example
Message TSC1 is send form Transmission Controller (address 03) to Engine Controller (00)
See parameter: EngRqedTorque_TorqueLimit. Parameter provided to the engine or retarder in the torque/speed control message for controlling or limiting the output torque.
This message type categorizes those Parameter Groups that convey a command to a specific or global destination from a source. The destination is then supposed to take specific actions based on the reception of this command message type. Both PDU1 (PS =Destination Address) and PDU2 Format (PS =Group Extension) messages can be used for commands. Example command type messages may include "Transmission Control," "Torque/Speed Control," etc.
Commands are send with a higher priority (3), than for example the message types sharing information ( priority 6).
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 27/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.4 MESSAGE TYPE: ACKNOWLEDGMENT (ACK)
GFV : group function value (*)
Example: 18 E8 FF EE
There are two forms of acknowledgment available. The first form is provided for by the CAN protocol. It consists of an "in-frame" acknowledgment which confirms that a message has been received by at least one node. In addition messages are further acknowledged by the absence of CAN error frames. Their absence acknowledges that all other powered and connected devices received the message correctly. The second form of acknowledgment is the response of a "normal broadcast" or "ACK" or "NACK" to a specific command or request as provided for by an application layer. For Group Function PGs the Group Function Value parameter allows a device to identify the specific group function that is being acknowledged. The Group Function Values are unique to each Group Function PG. It is desirable that the Group Function Values only use the range 0 to 250.
Overview Data length: 8 bytes Data Page: 0 PDU Format: 232 dec (E8 hex ). PDU Specific: Destination address =Global (255 dec ) Default priority: 6 PGN: 59392 dec (00E800 hex ) DATA field D0 Positive Acknowledgment: Control byte =0 Negative Acknowledgment: Control byte =1 Access Denied (PGN supported but security denied access) Control byte =2 Cannot Respond (PGN supported but ECU is busy and cannot respond now. Re-request the data at a later time.) Control byte =3
D1 Definition is specific to the individual PGN, when applicable. Most often it is located as the first byte in the data field of the applicable Group Function PG.
D5 to D7 contain requested PGN.
29 BIT IDENTIFIER DLC DATA FIELD Priority PGN SA 8 D0 D1 D2 D3 D4 D5 D6 D7 R DP PF DA Ctrl GFV FFh FFh FFh PGN 29 BIT IDENTIFIER DLC DATA FIELD Priority PGN SA 8 D0 D1 D2 D3 D4 D5 D6 D7 R DP PF DA Ctrl GFV FFh FFh FFh PGN Ctrl byte =0 ACK Ctrl byte =1 NACK Ctrl byte =2 access refused for safety reasons Ctrl byte =3 can not answer Ctrl byte =0-255 gereserveerd door SAE PDU Format=E8 hex
232 dec Destination address: Always Broadcast FF hex
Not used FF hex PGN of the requested message NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 28/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
Group functions This Message Type is used for groups of special functions (e.g. proprietary functions, network management functions, multi-packet transport functions, etc.). Each group function is recognized by its assigned PGN.
Proprietary Messages
The proprietary group function provides a means to transmit proprietary messages in a way that eliminates CAN Identifier usage conflicts between different manufacturers. It also provides a means for receiving and distinguishing proprietary messages for use when desired. Group Functions may need to provide their own request, ACK, and/or NACK mechanisms if the messages defined in J 1939-21 are not sufficient. A request using PGN 59904 can be used to find out if a specific Parameter Group of the message type, Group Function, is supported. If it is supported, then the responding device sends the Acknowledgment PGN with the control byte equal to zero, for Positive Acknowledgment, or equal to two, Access Denied or equal to three, Cannot Respond. If it is not supported, the responding device sends the Acknowledgment PGN with the control byte set to one, for Negative Acknowledgment. The remaining portions of the SAE J 1939 PDU format and Parameter Group must be filled in appropriately.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 29/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.6 MESSAGE TYPE: MULTI-PACKET TRANSPORT FUNCTIONS - LONG MESSAGES (GROUP FUNCTION)
Long Messages Messages requiring more than eight data bytes may be sent using the Multi-Packet message protocol, which allows messages of up to 1785 bytes. Each message is still identified with a particular PGN, and the technique is used usually for messages of variable lengths. The method uses an initial packet to set up the transfer, followed by up to 255 data packets. Each data packet must be separated by at least 50 ms.
Transport Protocol Functions Transport protocol functions are described as a part of the data link layer with the recognition that Transport protocol functionality is subdivided into two major functions: Message Packetization and Reassembly; and Connection Management.
They are described in the following sections. In the following paragraphs the term originator corresponds to the ECU or device that transmits the request-to- send message. The term responder corresponds to the ECU or device that transmits the clear-to-send message.
Packetization and Reassembly Messages greater than 8 bytes in length are too large to fit into a single CAN Data Frame. They must therefore be broken into several smaller packets, and those packets transmitted in separate message frames. At the destination end, the individual message frames must be received and parsed and the original message reassembled from the received packets.
Message Packets The CAN Data Frame includes an 8-byte data field. Because the individual packets which comprise a large message must be identified individually so that they may be reassembled correctly, the first byte of the data field is defined as the sequence number of the packet. Individual message packets are assigned a sequence number of 1 to 255. This yields a maximum message size of (255 packets * 7 bytes/packet =) 1785 bytes.
Sequence Numbers Sequence numbers are assigned to packets for transmission on the network during message packetization and then used on reception of packets to reassemble them back into a message. Sequence numbers shall be assigned to individual packets beginning with one and continuing sequentially until the entire message has been packetized and transmitted. The packets shall be sent sequentially in ascending order starting with packet 1.
Packetization A large message is defined as one whose data does not fit into the data field of a single CAN message frame (i.e. messages with a data field greater than 8 bytes). For the purposes of this protocol, a large message is considered to be a Parameter Group that has associated with it a string of 9 or more bytes. The first Data Transfer Packet contains the sequence number one and the first 7 bytes of the string. The second 7 bytes are placed into another SAE
J 1939/CAN data frame along with the sequence number 2, the third with sequence number 3, and so on until all the bytes in the original message have been placed into SAE J 1939/CAN data frames and transmitted. Each Data Transfer packet (other than the last packet in a transmission sequence) shall include 7 bytes of the original large message. The final packet includes a data field of 8 bytes: those being the sequence number of the packet and at least 1 byte of data related to the Parameter Group and then any remaining unused bytes set to "FF16'" The time between packets for Multipackets Broadcast messages shall be 50 to 200 ms (reference Section 5.12.3). For multi-packet messages directed to a specific destination, the originator maintains a maximum time between packets (where CTS allows more than one) of not more than 200 ms. Responders must be aware that the packets containing the data all have the same identifier.
Reassembly Data packets are received sequentially. Each data packet of a multipacket message shall be assembied, in order of sequence number, into a single string of bytes. This string of bytes is passed to the application entity responsible for the large message.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 30/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
The TP.CM BAM is used to inform all the nodes of the network that a large message is about to be broadcast. It defjnes the parameter group and the number of bytes to be sent. After TP.CM_BAM is sent, the Data Transfer Messages are sent and they contain the packetized broadcast data. TP.CM_BAM is only transmitted by the originator (sender).
Transport Protocol-Data Transfer Message (TP.DT) The TP.DT message is used to communicate the data associated with a Parameter Group. The TP.DT message is an individual packet of a multipacket message transfer. TP.DT is only transmitted by the originator (sender).
sender receivers TP.CM_BAM 32, 17, 3, 255 , 65260 TP.DT 1, data 1-7 TP.DT 2, data 8-14 TP.DT 3, data 15-17, 255, 255, 255, 255 TP.CM_BAM : Byte 0: Control byte: 32 dec (20 hex ) Byte 1-2: Total number of bytes to be transmitted: 17 Byte 3: Number of packets: 3 Byte 4: reserved for SAE Byte 5-7: PGN : 65260 TP.DT : Byte 0: sequence number: 1 Byte 1-7: data bytes: first 7 TP.DT : Byte 0: sequence number: 2 Byte 1-7: data bytes: bytes 8 to 14 TP.DT : Byte 0: sequence number : 3 Byte 1-7: data bytes: bytes 15 to 17 bytes not in use are filled with value 255. NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 31/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
7.6.2 Multipacket Destination Specific.
Sender 1 receiver TP.CM_RTS 16, 23, 4, 255, 65259 TP.CM_CTS 17, 2, 1, 255, 255, 65259 TP.DT 2, data 8-14 TP.DT 1, data 1-7 TP.CM_RTS : Byte 1: controle byte: 16 =RTS Byte 2-3: Total amount of bytes to send: 23 Byte 4: number of messages: 4 Byte 5: reserved for SAE Byte 6-8: PGN : 65259 TP.CM_CTS : Byte 1: controle byte: 17 =CTS Byte 2: number of bytes that can be received: 2 Byte 3: next databyte expected: 1 Byte 4-5:voorbehouden voor SAE Byte 6-8:PGN : 65259 TP.DT : Byte 1: sequence number: 1 Byte 2-8:data bytes: first 7 databytes 1-7 TP.CM_CTS 17, 0, 255, 255, 255, 65259 TP.CM_CTS 17, 2, 3, 255, 255, 65259 TP.DT 4, data 22-23 TP.DT 3, data 15-21 TP.EndofMsgACK 19, 23, 4, 255, 65259 TP.CM_CTS : Byte 1: controle byte: 17 =CTS Byte 2: number of bytes that can be received: 0 (0 =receiver wants a break.) Byte 4-5:reserved for SAE Byte 6-8:PGN : 65259 TP.CM_CTS : Byte 1: controle byte: 17 =CTS Byte 2: number of bytes that can be received: 2 Byte 3: number of the next databyte: 3 Byte 4-5:reserved voor SAE Byte 6-8:PGN : 65259
TP.EndofMsgACK: Byte 1: controle byte: 19 Byte 2-3: Total amount of received databytes: 23 Byte 4: total number of messages: 4 Byte 5: reserved for SAE Byte 6-8: PGN : 65259
TP.DT : Byte 1: sequence number : 2 Byte 2-8:data bytes: next 7 databytes 8-14 TP.DT : Byte 1: sequence number: 3 Byte 2-8:data bytes: next 7 databytes 15-21 TP.DT : Byte 1: sequence number: 4 Byte 2-8:data bytes: next 7 databytes 22-23 NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 32/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
Connection Mode Request to Send (TP.CM_RTS)
The TP.CM_RTS message informs a node that another node on the network wishes to open a virtual connection with it. The TP.CM_RTS is a message with the source address field set to that of the originating node, the destination address field set to that of the intended recipient of a large message, and the remaining fields set appropriately for the Parameter Group Number being gent. Byte 5 of this message allows the originator to limit the responder's number of packets specified in the Clear To Send message. When the responder complies with this limit, it ensures that the originator can always retransmit packets that the responder may have not received for whatever reason. It multiple RTSs are received from the same source address tor the same PGN, then the most recent RTS shall be acted on and the previous RTSs will be abandoned. No abort message shall be sent for the abandoned RTSs in this specific case. TP. CM_RTS is only transmitted by the originator.
Connection Mode Clear to Send (TP.CM_CTS) The TP.CM_CTS message is used to respond to the Request To Send message. It informs the peer node that it is ready for a certain amount of large message data. The amount of large message data cleared to send shall not be greater than byte 5 of the originator's TP.CM_RTS message. If multiple CTSs are received after a connection is al ready established, then the connection shall be aborted. When the originator aborts the connection, it shall send the Connection Abort message. The responder will not send the next CTS until it has received the last data packet from the previous CTS or it has timed out. If a CTS is received while a connection is not established, it shall be ignored. CTSs not only control the flow but also confirm correct receipt of any data packet prior to that CTS packet's number. Therefore if information for the previous CTS was corrupted, then a CTS for the corrupted information shall be sent before continuing on to the next sequential packets to be sent. Because of this requirement, the originator of a large message transmission may use byte 5 of the TP.CM_RTS message as a way to ensure the possibility of retransmission of a packet within the last set of packets cleared to send. TP.CM_CTS is only transmitted by the responder.
End of Message Acknowledgment (TP.CM_EndOfMsgACK) The TP.CM_EndOfMsgACK message is passed from the recipient of a large message to its originator indicating that the entire message was received and reassembled correctly. The responder can keep the connection open atter the last Data Transfer of the session by not immediately sending the TP.CM_EndOfMsgACK. This allows the responder to get a packet resent if necessary. If an End of Message Acknowledgment is received by the originator prior to the final Data Transfer, then the originator ignores it. One End of Message Acknowledgment is sent to show the originator that the large message transfer has been received and assem bied correctly. TP.CM_EndOfMsgACK is only transmitted by the responder.
Connection Abort (TP.Conn_Abort) The TP.Conn_Abort message is used by either node involved in a virtual connection to close the connection without completing the transfer of the message or to prevent a connection from being initialized. Upon receipt of a Connection Mode Request To Send message, a node must determine if there are sufficient resources available to deal with the message for which this connection is sought. For example if the device must acquire memory from the system heap, it may not be able to claim enough to accept the entire message; or a device may simply be too occupied doing other things to expend processor cycles to handle a large message. In these cases a Connection Abort message may be sent even though the connection has not been established. This may be done in order to allow the originator to attempt another virtual connection without first having to wait for a timeout to occur. When either the originator or responder decides to close out a connection for any reason, prior to completing the data transfer, including a timeout, it shall send a Connection Abort message with the appropriate Connection Abort reason.
It is intended that the originator (i.e. the RTS node) should immediately stop transmitting after the reception of the Connection Abort message by the CAN protocol device. If this is not possible, the process to stop transmitting data packets shall take no more than 32 data packets and shall not exceed 50 ms. After sending or receiving a Connection Abort message, all related data packets received should be ignored. TP.Conn_Abort is transmitted by the originator or the responder. NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 33/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
8 APPLICATION LAYER SAE J1939/73 : DIAGNOSTICS
8.1 DIAGNOSTIC MESSAGES (DM) NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 34/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
8.2 DM 1(DIAGNOSTIC MESSAGE 1) ACTIVE DIAGNOSTIC TROUBLE CODES
Diagnostics All compliant products will support the "DM1" message, which is a modified form of the SAE J 1939 version of the same PGN. This message allows the communication of diagnostic information and general operating status.
The form is as follows: Active Diagnostic Message ("DM1") PGN: 65226 PDU-F: 254 PDU-S: 202 Priority: 6. Node may increase priority if appropriate. Broadcast Rate: 1000 ms, plus at change of status. Data 1: Operating Status bit 0-1: Product is "On" bit 2-3: Product is "Active" (vs. "Standby") bit 4-5: Yellow Lamp. See diagnostic info for details. bit 6-7: Red Lamp. See diagnostic info for details. Data 2: Product Identifier (i.e. Default Source Address for the product) Data 3: Suspect Parameter Number (Most Sig. Bits) Data 4: Suspect Parameter Number Data 5: bit 5-7: Suspect Parameter Number (Least Sig. Bits) bit 0-4: Failure Mode Identifier Data 6: bit 7 Reserved (Always 1) bit 0-6 - Occurrence count. (If unavailable, 1111111).
If multiple failures are occurring, the transmitter has a choice of sending this as a multi-packet message (see next section) or simply sending multiple instances of this message. In the former case, data bytes 3-6 are chained sequentially, so the message is in this order: Lamp Status, SPN/FMI/Count, SPN/FMI/Count, . . . SPN/FMI/Count. When a problem is cleared up, the message should be sent showing the lamps as unlit. All conditions should be classified as "Yellow" or "Red". A "Yellow" condition would usually refer to a problem that can be remedied by the user (e.g. Low Battery Level to an Inverter) or does not require intervention. A "Red" condition would generally require a service technician. These levels are subjective, of course.
ACTIVE FAILURE MIL DTC BROADCAST DM 1 NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 35/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
8.3 DATA FIELDS OF A DM1 MESSAGE
8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8
MIL STATUS SPN RESERVED SPN SPN FMI CM OC NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 36/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
8.4 FMI FAILURE MODE INDICATION
The committee is charged with providing a list of SPNs. The Failure Modes are defined as follows: 0 Item above normal operating range 1 Item below normal operating range 2 Item erratic, intermittent, or invalid 3 Short circuit high voltage (or complete sensor input failure) 4 Short circuit low voltage (or complete sensor input failure) 5 Current below normal, or Open circuit 6 Current above normal, or Grounded circuit 7 Mechanical system not responding 8 Abnormal frequency, pulse width, or period 9 Abnormal update rate 10 Abnormal rate of change 11 Failure not identifiable 12 Bad intelligent device or component 13 Out of calibration 14 "None of the above" (Use sparingly!) 15-30 Reserved 31 No failure information available (note: use when the SPN is unknown. If SPN is known, use FMI 11). NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 37/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
9 NETWORK MANAGEMENT
9.1 NETWORK ADRESSES AND NAMES
On a J 1939 network, each device has a unique address. Each message that is sent by a device contains this source address. There are 255 possible addresses: 0..253 Valid addresses of an ECU 254 Zero 255 Global
Each device type has a preferred address. Before a device may use an address, it must register itself on the bus. This procedure is called "address claiming." Thereby the device sends an "AddressClaim" parameter group with the desired source address. This PG contains a 64-bit device name. If an address is already used by another device, then the device whose device name has the higher priority has received the address. The device name contains some information about the device and describes its function. Since the function of a device is contained in the name, the address can be changed at will and the correct device is always addressed that provides the required functionality.
There are examples, such as an engine and engine retarder residing in a common ECU, wherein multiple names and multiple addresses may coexist within a single electronics unit. The address of an ECU defines a specific communications source or destination for messages; the name includes identification of the primary function performed at that address and adds an indication of the instance of that functionality in the event that multiple ECUs with the same primary function coexist on the same network. As many as 254 different ECUs of the same function can coexist on the network, each identified by their own address and name.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 38/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
9.2 SAE J1939 INDUSTRY GROUPS PREFERRED NETWORK ADDRESSES
SAE name for INDUSTRY GROUP 0 Network address (hex) Netwerk address (dec)
Engine 00 00 Transmission 03 03 Shift console 05 05 Brake system controller 0B 11 Retarder engine 0F 15 Retarder driveline 10 16 Exhaust retarder 29 41 Suspension system controller 2F 47 Pneumatic system controller 30 48 Cab controller 31 49 Rear axle steering control 38 56 Exhaust emission controller (i.e. Adblue) 3D 61 Vehicle dynamic stability controller 3E 62
INDUSTRY GROUP 1/ on highway equipment Tachograph EE 238
Industry Group To permit multiple industries to use J 1939, an lndustry Group code is used to identify the industry to which the ECU is associated. Code 0 is a special category of lndustry Group in that it identifies Preferred Addresses and NAMEs that are common to all industries. Any ECU which may be used in more than one industry application, such as diesel engines, should have NAMEs and Preferred Addresses within this global group. It is the responsibility of those requesting new definitions to consider if this may be the case, and to request the new definition in the correct group. To avoid running out of NAME or address values, it is requested that global values be used only when truly applicable, if an ECU may exist in only one group, such as agricultural equipment, it would be preferable to add the definition to the applicable group rather than to use a global value.
NETWORKS IN TRUCKS AND BUSSES CAN SAE J 1939 39/39
KATHO department VHTI Industrial Sciences and Technology study area Bachelor of Automotive KORTRIJ K - BELGIUM frans.devolder @ katho.be 13-May-07
SEMINAR CONTROLLER AREA NETWORK IN TRUCKS 31 May 2007 Escola Superior de Tecnologia - Campus do Instituto Politcnico de Setbal - Estefanilha, 2910-761 Setbal PORTUGAL
9.3 PROCEDURE ADDRESS CLAIMING
ADDRESS REQUEST PGN: 59904 PDU-F: 234 PDU-S: desired networkaddress Priority: 6 Data Length: 3 Broadcast Rate: As Needed Source Address: 254 is no address has been claimed. Data 1: 0 Data 2: 238 Data 3: 0
ADDRESS CLAIMED PGN: 60928 PDU-F: 238 PDU-S: 255 Priority: 6 Broadcast Rate: On Request Only Source Address: Source Address. Data 1-8: " DEVICE NAME". (8 byte identification for a module).
NAMEs identify the primary vehicle function or functions which an ECU performs and uniquely identify each ECU, even when there is more than one of the same type on the network. But with a length of 64 bits, a NAME is inconvenient to use in normal communications. Therefore, once the network is fully initialized, each ECU utilizes an 8 bit address as its source identifier or "handle" to provide a way to uniquely access a given ECU on the network. For example, an engine may be assigned address 0, but if a second engine is present, it needs a separate, unique address (e.g. 1) and instance. ECUs that accept destination specific commands may require multiple addresses. This permits distinguishing which action is to occur. For example, if the transmission is commanding a specific torque value from the engine (address 0), this must be differentiated from commanding a specific torque value from the engine brake retarder)(address 15). As can be seen by this example, a single ECU on the network may have multiple addresses and each address will have an associated NAME. To facilitate the initialization process of determining the address (es) for each ECU on the network, commonly used devices have Preferred Addresses assigned by the committee. Using the Preferred Addresses minimizes the frequency of multiple devices attempting to claim the same address.
In general, most ECUs will use their Preferred Addresses immediately upon power up. A specific procedure (defined in J 1939/81 and elaborated on in J 1939/01) for assigning addresses after powerup is used to resolve any conflicts that may occur. Each ECU must be capable of announcing which address(es) it intends to use. This is the address claim feature.
Two options are available:
1) Upon power-up and whenever requested, an ECU must send an Address Claimed message to claim an address. When an ECU sends the Address Claimed message, all ECUs record or compare this newly claimed address to their own table of addresses on the network. Not all ECUs are required to maintain such a table, but all must at least compare the newly claimed address with their own. Should multiple ECUs claim the same address, the one having the lowest value NAME uses this address and the other(s) must claim a different address or stop transmitting on the
2) An ECU may send a request for Address Claimed message to determine addresses claimed by other ECUs. When an ECU sends a request for Address Claimed, all requested ECUs then send their Address Claimed messages. This permits transitional ECUs (tools, trailers, etc.) or ECUs powering up late to obtain the current address table so that an available address can be found and claimed or to determine which ECUs are currently on the network.