Exchangers
Scambiatori di calore per gas
di scarico
Abgaswrmetauscher
BS EN ISO 9001-2008
Reg. No. FM38224
2
Exhaust Gas Heat Exchangers
These heat exchangers are designed to remove thermal energy from the exhaust gas of natural gas,
diesel and bio-fuel engines and transfer it to the water circuit. The extracted heat can be used for
space heating, domestic hot water and any industrial process that requires hot water.
Standard range available for quick delivery.
Suitable for engines up to 1MW.
Suitable for use with engines powered by conventional or alternative fuels.
Fully welded stainless steel construction for reliability and durability.
Can also be used to extract energy from gas or air and transfer it to a
water circuit.
Compact and efficient design for ease of
installation.
Ideal for reducing the exit temperature of the
exhaust gases in hazardous areas.
Used in conjunction with jacket water, charge air,
fuel and oil coolers, Bowman units can reclaim up
to 60% of waste heat from an engine.
Bowman units when fitted provide FREE HEATING
& HOT WATER.
Automated tube end welding
and 100% inspection
Given the following information, we can recommend a unit
for your requirements:
Fuel type
Exhaust gas mass flow rate
Exhaust gas inlet temperature
Water circuit inlet temperature and flow rate
3
Combined Heat Recovery Performance Table
This table shows the heat that can be removed from each type of heat exchanger as shown in the illustration above.
Combined Heat Recovery
The above figures should be used as a guide only, optimised design is available on request.
Typical configuration for CHP using Bowman Heat Exchangers
SECONDARY
WATER INLET
Provision should be made for cooling the engine water, oil and gas when heat recovery is not required.
EXHAUST GAS HEAT EXCHANGER
CHARGE AIR
COOLER
OIL COOLER
HEADERTANK
HEAT EXCHANGER
SECONDARY
WATER OUTLET
The addition of Bowman exhaust gas heat exchangers enable waste heat recovery from the
exhaust gas and can be used on Cogeneration/Combined Heat and Power (CHP) equipment.
Type
Engine Power
kW
Jacket Water
kW
Engine Oil
kW
Charge Air
Cooler
kW
Exhaust Gas
kW
Total Reclaimed
Energy
kW
2" 16 5 2 2.5 11.5 20.5
3" 32 10 4 5 23 41
4" 60 18 7 9 43 77
5" 90 27 10 14 65 115
6" 140 42 15 21 101 179
8" 250 75 28 38 181 321
10" 400 120 44 60 288 512
12" 600 180 66 90 425 761
15" 950 280 104 142 670 1205
Exhaust Gas Heat Exchanger Performance Table
Typical examples of exhaust gas heat exchanger performance
The figures below are a general guide only and are not based on any particular natural gas engine. They assume
an air/fuel ratio of 10.23 : 1 by volume, a fuel consumption of 0.34m
3
/kWh (measured at 1.013 bar and 15C) and
an exhaust gas temperature of 600C and a water inlet temperature of 80C.
Maximum working gas side pressure 0.5 bar
Maximum working water side pressure 4 bar
Maximum working gas side temperature 700C
Maximum working water side temperature 110C
For larger sizes contact our sales department.
European Pressure Equipment Directive
This range of products fall within Article 3 Paragraph 3
(Sound Engineering Practice) and do not require CE marking.
4
Type
Typical
Engine Power
kW
Exhaust gas flow
kg/min
Exhaust gas
outlet temp
C
Heat recovery
kW
Exhaust gas
pressure drop
kPa
2-25-3737-4 16 1.2 210 9.5 1.6
2-32-3737-5 16 1.2 170 11.5 1.8
3-32-3738-5 32 2.4 210 19 1.5
3-40-3738-6 32 2.4 170 21 1.7
3-60-3738-8 32 2.4 120 23 2.2
4-32-3739-5 60 4.5 210 35 1.3
4-40-3739-6 60 4.5 170 39 1.4
4-60-3739-8 60 4.5 120 43 1.8
5-32-3740-5 90 6.7 210 53 1.2
5-40-3740-6 90 6.7 170 58 1.4
5-60-3740-8 90 6.7 120 65 1.8
6-32-3741-5 140 10.5 210 82 1.3
6-40-3741-6 140 10.5 170 90 1.4
6-60-3741-8 140 10.5 120 101 1.9
8-32-3742-5 250 18.7 210 147 1.3
8-40-3742-6 250 18.7 170 161 1.4
8-60-3742-8 250 18.7 120 181 1.8
10-32-3743-5 400 30.0 210 236 1.3
10-40-3743-6 400 30.0 170 256 1.4
10-60-3743-8 400 30.0 120 288 1.8
12-32-3744-5 600 45.0 210 353 1.3
12-40-3744-6 600 45.0 170 388 1.5
12-60-3744-8 600 45.0 120 425 1.9
15-40-5745-6 950 70.0 170 604 1.4
15-60-5745-8 950 70.0 120 670 1.9
100kPa =1 bar
Exhaust Gas Heat Exchangers
There are three ranges of Bowman exhaust gas heat exchangers, without end covers for connection directly to
customers pipework (see page 5), straight end covers with PN6 flange connections (see page 6) and 90 end
covers with PN6 connections and removable end plates for maintenance (see page 7). All models include a
pressure relief valve as standard.
Shell side flanges are PN6 to BS EN1092 as are the straight and 90 end cover flanges. Tubeplate flange
dimensions are shown in the table on page 5.
5
B
D
F " BSP
"
B
S
P
WATER DRAIN PLUG
WASSERABLASSSCHRAUBE
TAPPO PER IL DRENAGGIO DELL'ACQUA
A
C
H
G
K
E
+ x OJ
" BSP
"
B
S
P
A
B
C
E
F
H
G
L
Type A B C D E F G H I J K L kg
mm mm mm mm mm BSP mm mm mm mm
2-25-4737-4 648 550 588 60.3 106
3
4" 65 55 60 9 90 PCD 4 x 9 7
2-32-4737-5 826 728 766 60.3 106
3
4" 65 55 60 9 90 PCD 4 x 9 8
3-32-4738-5 826 718 760 88.9 136 1" 75 75 60 9 120 PCD 8 x 9 14
3-40-4738-6 1028 920 962 88.9 136 1" 75 75 60 9 120 PCD 8 x 9 17
3-60-4738-8 1536 1428 1470 88.9 136 1" 75 75 60 9 120 PCD 8 x 9 23
4-32-4739-5 826 698 760 114.3 160 1
1
2" 90 90 80 9 144 PCD 8 x 9 20
4-40-4739-6 1028 900 962 114.3 160 1
1
2" 90 90 80 9 144 PCD 8 x 9 23
4-60-4739-8 1536 1408 1470 114.3 160 1
1
2" 90 90 80 9 144 PCD 8 x 9 32
5-32-4740-5 826 688 760 141.3 194 2" 105 105 100 11 174 PCD 8 x 11 28
5-40-4740-6 1028 890 962 141.3 194 2" 105 105 100 11 174 PCD 8 x 11 32
5-60-4740-8 1536 1398 1470 141.3 194 2" 105 105 100 11 174 PCD 8 x 11 45
Type A B C D E F G H I J K L kg
mm mm mm mm mm mm mm mm mm
6-32-4741-5 826 668 760 168.3 220 DN65 120 140 130 11 200 PCD 8 x 11 40
6-40-4741-6 1028 870 962 168.3 220 DN65 120 140 130 11 200 PCD 8 x 11 47
6-60-4741-8 1536 1378 1470 168.3 220 DN65 120 140 130 11 200 PCD 8 x 11 65
8-32-4742-5 826 648 750 219 284 DN80 150 180 180 14 260 PCD 8 x 14 66
8-40-4742-6 1038 850 952 219 284 DN80 150 180 180 14 260 PCD 8 x 14 74
8-60-4742-8 1536 1358 1460 219 284 DN80 150 180 180 14 260 PCD 8 x 14 102
10-32-4743-5 826 608 750 273 340 DN100 180 220 250 14 314 PCD 12 x 14 94
10-40-4743-6 1028 810 952 273 340 DN100 180 220 250 14 314 PCD 12 x 14 108
10-60-4743-8 1536 1318 1460 273 340 DN100 180 220 250 14 314 PCD 12 x 14 148
12-32-4744-5 826 538 736 324 410 DN125 220 260 300 18 376 PCD 12 x 18 132
12-40-4744-6 1028 740 938 324 410 DN125 220 260 300 18 376 PCD 12 x 18 151
15-40-4745-6 1028 740 912 406.4 495 DN150 280 320 350 18 460 PCD 16 x 18 231
15-60-4745-8 1536 1248 1420 406.4 495 DN150 280 320 350 18 460 PCD 16 x 18 316
Flange F to BS EN 1092-1:2007 - PN6.
6
A
B
C
E
F
4 x J
L
M
" BSP
"
B
S
P
WATER DRAIN PLUG
WASSERABLASSSCHRAUBE
TAPPO PER IL DRENAGGIO DELL'ACQUA
G
H
K
A
B
C
E
F
G
H
+ x OJ
L
K
M
" BSP
"
B
S
P
WATER DRAIN PLUG
WASSERABLASSSCHRAUBE
TAPPO PER IL DRENAGGIO DELL'ACQUA
Type A B C D E F G H I J K L M kg
mm mm mm mm mm BSP mm mm mm mm mm mm
2-25-3737-4 750 550 588 60.3 100
3
4" 65 55 60 9 DN25 34 12 10
2-32-3737-5 928 728 766 60.3 100
3
4" 65 55 60 9 DN25 34 12 12
3-32-3738-5 960 718 760 88.9 140 1" 75 75 60 9 DN50 54 16 18
3-40-3738-6 1162 920 962 88.9 140 1" 75 75 60 9 DN50 54 16 20
3-60-3738-8 1670 1428 1470 88.9 140 1" 75 75 60 9 DN50 54 16 27
4-32-3739-5 990 698 760 114.3 160 1
1
2" 90 90 80 9 DN65 66 22 25
4-40-3739-6 1192 900 962 114.3 160 1
1
2" 90 90 80 9 DN65 66 22 29
4-60-3739-8 1700 1408 1470 114.3 160 1
1
2" 90 90 80 9 DN65 66 22 40
5-32-3740-5 1030 688 760 141.3 190 2" 105 105 100 11 DN80 82 26 36
5-40-3740-6 1232 890 962 141.3 190 2" 105 105 100 11 DN80 82 26 39
5-60-3740-8 1740 1398 1470 141.3 190 2" 105 105 100 11 DN80 82 26 51
Type A B C D E F G H I J K L M kg
mm mm mm mm mm mm mm mm mm mm mm
6-32-3741-5 1080 668 760 168.3 210 DN65 120 140 130 11 DN100 104 28 48
6-40-3741-6 1282 870 962 168.3 210 DN65 120 140 130 11 DN100 104 28 55
6-60-3741-8 1790 1378 1470 168.3 210 DN65 120 140 130 11 DN100 104 28 72
8-32-3742-5 1150 648 750 219 240 DN80 150 180 180 14 DN125 130 40 89
8-40-3742-6 1352 850 952 219 240 DN80 150 180 180 14 DN125 130 40 98
8-60-3742-8 1860 1358 1460 219 240 DN80 150 180 180 14 DN125 130 40 125
10-32-3743-5 1230 608 750 273 265 DN100 180 220 250 14 DN150 154 55 132
10-40-3743-6 1432 810 952 273 265 DN100 180 220 250 14 DN150 154 55 146
10-60-3743-8 1940 1318 1460 273 265 DN100 180 220 250 14 DN150 154 55 185
12-32-3744-5 1330 538 736 324 320 DN125 220 260 300 18 DN200 204 55 190
12-40-3744-6 1532 740 938 324 320 DN125 220 260 300 18 DN200 204 55 208
12-60-3744-8 2040 1248 1446 324 320 DN125 220 260 300 18 DN200 204 55 268
15-40-5745-6 1670 740 912 406.4 375 DN150 280 320 350 18 DN250 254 70 319
15-60-5745-8 2180 1248 1420 406.4 375 DN150 280 320 350 18 DN250 254 70 404
Flange F to BS EN 1092-1:2007 - PN6.
Flange K to BS EN 1092-1:2007 - PN6.
7
B
C
D
F
4 x J
" BSP
"
B
S
P
WATER DRAIN PLUG
WASSERABLASSSCHRAUBE
TAPPO PER IL DRENAGGIO DELL'ACQUA
A
B1
H
G
E
L
K
A
B1
B
C
E
L
" BSP
"
B
S
P F
D
+ x OJ
WATER DRAIN PLUG
WASSERABLASSSCHRAUBE
TAPPO PER IL DRENAGGIO DELL'ACQUA
H
G
K
Type A B B1 C D E F G H I J K L kg
mm mm mm mm mm mm BSP mm mm mm mm mm
2-25-5837-4 920 550 770 588 60.3 100
3
4" 65 70 60 9 DN25 34 13
2-32-5837-5 1098 728 950 760 60.3 100
3
4" 65 70 60 9 DN25 34 14
3-32-5838-5 1198 718 999 760 88.9 140 1" 75 85 60 9 DN50 54 24
3-40-5838-6 1400 920 1200 962 88.9 140 1" 75 85 60 9 DN50 54 27
3-60-5838-8 1908 1428 1708 1470 88.9 140 1" 75 85 60 9 DN50 54 33
4-32-5839-5 1237 698 1019 760 114.3 160 1
1
2" 90 100 80 9 DN65 66 33
4-40-5839-6 1439 900 1221 962 114.3 160 1
1
2" 90 100 80 9 DN65 66 37
4-60-5839-8 1948 1408 1729 1470 114.3 160 1
1
2" 90 100 80 9 DN65 66 46
5-32-5840-5 1306 688 1049 760 114.3 190 2" 105 120 100 11 DN80 82 51
5-40-5840-6 1504 890 1251 962 114.3 190 2" 105 120 100 11 DN80 82 55
5-60-5840-8 2010 1398 1759 1470 114.3 190 2" 105 120 100 11 DN80 82 68
Type A B B1 C D E F G H I J K L kg
mm mm mm mm mm mm mm mm mm mm mm
6-32-5841-5 1400 668 1100 760 168.3 210 DN65 120 140 130 11 DN100 104 72
6-40-5841-6 1604 870 1302 962 168.3 210 DN65 120 140 130 11 DN100 104 79
6-60-5841-8 2110 1378 1810 1470 168.3 210 DN65 120 140 130 11 DN100 104 96
8-32-5842-5 1446 468 1120 750 219 240 DN80 150 180 180 14 DN125 130 119
8-40-5842-6 1648 850 1322 952 219 240 DN80 150 180 180 14 DN125 130 128
8-60-5842-8 2156 1358 1830 1460 219 240 DN80 150 180 180 14 DN125 130 155
10-32-5843-5 1528 608 1159 750 273 265 DN100 180 220 250 14 DN150 154 180
10-40-5843-6 1730 810 1361 952 273 265 DN100 180 220 250 14 DN150 154 193
10-60-5843-8 2238 1318 1869 1460 273 265 DN100 180 220 250 14 DN150 154 234
12-32-5844-5 1720 538 1249 736 323.9 320 DN125 220 260 300 18 DN200 204 272
12-40-5844-6 1920 740 1451 938 323.9 320 DN125 220 260 300 18 DN200 204 292
12-60-5844-8 2430 1248 1959 1446 323.9 320 DN125 220 260 300 18 DN200 204 348
15-40-5845-6 2080 740 1531 912 406.4 375 DN150 280 320 350 18 DN250 254 428
15-60-5845-8 2590 1248 2039 1420 406.4 375 DN150 280 320 350 18 DN250 254 513
Flange F to BS EN 1092-1:2007 - PN6.
Flange K to BS EN 1092-1:2007 - PN6.
Installation
The heat exchanger must be installed horizontally and levelled accurately, with the primary circuit
(tubeside) through the tubes and the secondary circuit (shellside) over the tubes. The heat exchanger
should only be connected in counter flow with the secondary circuit (shellside) connections always
being positioned on top. (See schematic diagram below).
Alternative installations may also be acceptable; consultation with our technical department for
acceptance should be made prior to installation.
It is very important that the secondary circuit is fully vented via the vent plug fitted in order to prevent any
aeration taking place which can cause erosion of the tubes.
If ethylene glycol or any other heat transfer fluid is used in the secondary circuit, adequate mixing should
be performed prior to filling of the heat exchanger.
If temperature control sensors are fitted to either the primary or secondary circuits of the heat exchanger,
they should be fitted to the inlet circuit and not the outlet circuit in order to provide accurate temperature
readings.
The pressure relief valve should not be removed or tampered with.
Operation
Adequate provision should be made to ensure that in the event of the primary circuit being shutdown, the
secondary circuit continues to operate for a period of time to enable the dispersal of residual heat to an
acceptable level, preventing any damage to the heat exchanger.
Adequate provision should also be made to ensure that the secondary circuit pumps are in continual
operation whenever the primary circuit is in operation.
Provision should also be made to ensure that any valves or ancillary equipment associated with either
the primary or secondary side of the heat exchanger can not be accidentally turned off, thereby
preventing flow through the heat exchanger.
Installation and Operating Instructions
EXHAUST GAS
INLET
PRIMARY CIRCUIT
PRIMARY CIRCUIT
EXHAUST GAS
OUTLET
SECONDARY CIRCUIT
OUTLET
SECONDARY CIRCUIT INLET
PRESSURE
RELIEF VALVE
VENT
PLUG
Exhaust Gas Heat Exchanger
8
9
Abgaswrmetauscher
Diese Wrmetauscher sind fr die Wrmerckgewinnung von Abgasen von Erdgas-, Diesel- und
Biobrennstoffmotoren und fr deren bertragung auf den Wasserkreislauf ausgelegt. Die extrahierte Wrme
kann zur Raumheizung, zur Erwrmung von Brauchwarmwasser und fr alle industrielle Prozesse, die warmes
Wasser bentigen, verwendet werden.
Standardsortiment zur schnellen Lieferung verfgbar.
Geeignet fr Motoren bis 1 MW.
Geeignet fr Verwendung mit Motoren, die mit konventionellen und alternativen Brennstoffen
angetrieben werden.
Voll geschweite Edelstahlkonstruktion zwecks Zuverlssigkeit und
Haltbarkeit.
Dient ebenfalls zur Energiegewinnung aus Gas oder Luft und zur
bertragung auf den Wasserkreislauf.
Kompakt und sehr leistungsfhiges Design zum leichten Einbau.
Ideal zur Absenkung der Austrittstemperatur der Abgase in
gefhrlichen Umgebungen.
In Verwendung zusammen mit Mantelwasser, Ladeluft, Brennstoff- und
lkhlern, knnen Bowman Wrmetauscher bis zu 60% der Abwrme
von einem Motor rckgewinnen.
Eingebaute Bowman Wrmetauscher sorgen fr kostenloses Heizen
und Warmwasser.
Automatisiertes Schweien
des Rohrendes und
100% Kontrolle.
Installation
Der Wrmetauscher ist horizontal zu montieren und genau einzuebnen, wobei der Primrkreislauf (rohrseitig) durch
die Rohre und der Sekundrkreislauf (mantelseitig) ber die Rohre zu installieren ist. Der Wrmetauscher sollte nur
im Gegenstrom angeschlossen werden, wobei die Anschlsse des Sekundrkreislaufs (mantelseitig) stets auf der
Oberseite positioniert sein sollten.
Alternative Installationen sind ebenfalls zulssig. Konsultieren Sie bitte unsere technische Abteilung vor der
Installation.
Sehr wichtig ist, dass der Sekundrkreislauf durch den eingesetzten Entlftungsstutzen vllig entlftet ist, um
Luftzufuhr zu verhindern, was zu einer Korrosion der Rohre fhren kann.
Falls thylenglykol oder irgendeine andere Wrmetrgerflssigkeit im Sekundrkreislauf verwendet wird, soll es
bzw. sie vor dem Auffllen des Wrmetauschers gut vermischt werden.
Falls Temperaturfhler entweder im Primr- oder Sekundrkreislauf des Wrmetauschers einzubauen sind, sollten
sie nicht in den Auslasskreislauf sondern in den Einlasskreislauf eingebaut werden, damit genaue
Temperaturmessungen durchgefhrt werden knnen.
Das berdruckventil sollte nicht entfernt oder verndert werden.
Betrieb
Es sollten geeignete Vorkehrungen getroffen werden, um sicherzustellen, dass im Falle einer Abschaltung des
Primrkreislaufs der Sekundrkreislauf fr eine Zeit lang weiterhin funktioniert, um die Verteilung der Restwrme
bei einem akzeptablen Fllstand zu ermglichen und um jeglichen Schaden am Wrmetauscher zu verhindern.
Geeignete Vorkehrungen sollten ebenfalls getroffen werden, um sicherzustellen, dass die Pumpen im
Sekundrkreislauf im kontinuierlichen Betrieb sind, immer wenn der Primrkreislauf im Betrieb ist.
Ferner sollten Manahmen ergriffen werden, um sicherzustellen, dass jegliche Ventile oder entweder zur primren
oder sekundren Seite des Wrmetauschers zugehrige Zusatzausrstung nicht versehentlich ausgeschaltet
werden knnen bzw. kann, was somit den kontinuierlichen Durchfluss durch den Wrmetauscher verhindern wrde.
Installations- und Betriebsanleitung
Anhand der folgenden Informationen knnen unsere Wrmetechniker einen
fr Ihre Anforderungen spezifischen Wrmetauscher empfehlen:
Brennstofftyp, Massenstrom des Abgases, Eintrittstemperatur des
Abgases, Eintrittstemperatur und Durchflussmenge des Wasserkreislaufs.
Saldatura automatica dei
terminali delle tubazioni
e ispezione al 100%
Scambiatori di calore per gas di scarico
Questi scambiatori di calore sono studiati per estrarre energia termica dai gas di scarico dei motori a
metano, diesel e bio carburante e trasferirla al circuito ad acqua. Il calore estratto pu essere utilizzato per
il riscaldamento degli ambienti, dellacqua calda residenziale e per qualsiasi processo industriale che
richieda acqua calda.
Gamma standard disponibile per spedizione immediata.
Idonei per motori fino a 1 MW.
Idonei per luso con motori alimentati da carburanti convenzionali e alternativi.
Costruzione in acciaio inossidabile completamente saldata per una maggiore affidabilit
e durata.
Possono essere usati per estrarre energia da gas o aria e
trasferirla a un circuito ad acqua.
Design compatto e altamente efficiente per una facile installazione.
Ideali per ridurre la temperatura in uscita dei gas di scarico in aree
pericolose.
Usati insieme a camicie dacqua, intercooler, raffreddatori dolio e
carburante, le unit Bowman sono in grado di utilizzare fino al 60%
del calore di scarico prodotto da un motore.
Le unit Bowman forniscono RISCALDAMENTO e ACQUA CALDA
GRATIS.
Installazione
Lo scambiatore di calore deve essere installato orizzontalmente e livellato con precisione, con il circuito
principale (lato tubo) installato nei condotti e il circuito secondario (lato rivestimento) installato sulle tubazioni. Lo
scambiatore di calore deve essere collegato solo in controflusso con le connessioni del circuito secondario (lato
rivestimento) sempre in alto.
Possono essere idonee anche installazioni alternative; a questo proposito, richiedere lapprovazione del progetto
al nostro reparto tecnico prima di effettuare linstallazione.
E molto importante che il circuito secondario sia completamente sfiatato attraverso la bocchetta montata per
evitare che uneventuale aerazione possa corrodere le tubazioni.
Se nel circuito secondario viene utilizzato etilenglicole o altri fluidi per il trasferimento del calore necessario
preparare una miscela idonea prima di riempire lo scambiatore.
Se i sensori di controllo della temperatura sono montati sul circuito principale o secondario dello scambiatore di
calore, dovranno essere montati nei circuiti interni e non su quelli esterni per permettere unaccurata lettura delle
temperature.
La valvola di rilascio della pressione non deve essere rimossa o manomessa.
Funzionamento
E necessario adottare adeguate misure al fine di garantire che in caso di spegnimento del circuito principale, il
circuito secondario continui a funzionare per un periodo sufficiente a disperdere il calore residuo fino a livelli
accettabili, proteggendo in questo modo lo scambiatore da eventuali danni.
E necessario inoltre far s che le pompe del circuito secondario rimangano in continuo funzionamento quando
il circuito principale in funzione.
E necessario accertarsi che le valvole o le attrezzature ausiliarie associate al lato principale o secondario dello
scambiatore di calore non possano essere accidentalmente chiuse impedendo il regolare flusso attraverso lo
scambiatore.
Istruzioni di installazione e funzionamento
Date le seguenti informazioni, i nostri ingegneri termici possono
consigliare lunit pi adatta per ogni specifica applicazione:
Tipo di carburante, Portata del gas di scarico, temperatura del gas
in entrata, temperatura e flusso in entrata al circuito dellacqua.
10
11
Spalinowe wymienniki ciepa
Te wymienniki ciepa s zaprojektowane w taki sposb, e odprowadzaj energi ciepln ze spalin wydalanych
przez silniki zasilane gazem ziemnym, biopaliwem bd silniki Diesla i przekazuj j do obwodu wodnego.
Wydobyte ciepo moe by wykorzystane do ogrzewania pomieszcze, grzania wody do uytku domowego, a
take w dowolnych procesach przemysowych, ktre wymagaj uycia gorcej wody.
Zapewnia si szybk dostaw standardowego asortymentu.
Odpowiednie do silnikw do 1 MW.
Nadaj si do stosowania z silnikami napdzanymi paliwami konwencjonalnymi oraz
alternatywnymi.
Cakowicie szczelna konstrukcja ze stali nierdzewnej gwarantuje trwao i niezawodno.
Mog by take wykorzystane do pozyskiwania energii z gazu lub
powietrza i przenoszenia jej do obwodu wodnego.
Zwarta i wysoko wydajna struktura uatwia monta.
Idealnie nadaj si do obniania temperatury wyjciowej gazw w
niebezpiecznych miejscach.
Urzdzenia Bowman uywane w poczeniu z paszczowym
systemem schadzania wody, chodnic powietrza doadowujcego,
chodnic paliwa czy oleju, mog odzyska do 60% ciepa
utraconego z silnika.
Prawidowo dostosowane urzdzenia Bowman zapewniaj
DARMOWE CIEPO I GORC WOD.
Automatyczne czenie
kocwki rury i cakowita
kontrola
Monta
Wymiennik ciepa musi by zainstalowany poziomo i dokadnie wyrwnany, przy czym obwd pierwotny (rurowy)
powinien by zamontowany przelotowo przez rury, a obwd wtrny (paszczowy) nad rurami. Wymiennik ciepa
powinien by podczony tylko z obwodem wtrnym w przepywie przeciwprdowym, a zcza zawsze naley
umieszcza na grze. (Zob. schemat poniej).
Moliwe jest take alternatywne podczenie, jednak wczeniej naley skonsultowa si w tej sprawi z dziaem
technicznym w celu uzyskania zgody.
Bardzo wane jest to, aby obieg wtrny by w peni odpowietrzany poprzez dopasowane odpowietrzniki, dziki
czemu zapobiega si napowietrzaniu, ktre moe by przyczyn korodowania rur.
Jeeli w obiegu wtrnym ma by wykorzystany glikol etylenowy lub inny pyn przenoszcy ciepo, przed
napenieniem wymiennika naley przygotowa odpowiedni mieszank.
Jeeli do pierwotnego bd wtrnego obwodu wymiennika ciepa przymocowane s czujniki kontroli temperatury,
powinny by one zainstalowane przy wlocie do obiegu, a nie przy wylocie, aby dziki temu zapewni prawidowy
odczyt temperatury.
Nie naley usuwa zaworu bezpieczestwa ani przy nim manipulowa.
Dziaanie
Naley podj odpowiednie kroki majce na celu zapewnienie dziaania obwodu wtrnego, w przypadku gdy obwd
pierwotny przestanie pracowa. Obwd wtrny powinien wtedy dziaa przez pewien czas, umoliwiajc
rozprzestrzenianie si ciepa uytkowego na zadowalajcym poziomie i chronic wymiennik ciepa przed
uszkodzeniem.
Naley rwnie zapewni, aby pompy obwodu wtrnego byy w cigym dziaaniu, zawsze gdy dziaa obwd
pierwotny.
Naley take podj waciwe kroki w celu zabezpieczenia wszelkich zaworw i dodatkowych urzdze zwizanych
z pierwotnym bd wtrnym dziaaniem wymiennika ciepa, aby nie dopuci do jego przypadkowego wyczenia i
wstrzymania przepywu.
Monta i instrukcja dziaania
Biorc pod uwag ponisze dane, nasi specjalici od systemw cieplnych mog
poleci Pastwu urzdzenie dostosowane do okrelonych potrzeb.
Rodzaj paliwa
Wskanik masowego natenia przepywu spalin
Temperatura spalin przy wlocie
Temperatura przy wlocie do obwodu wodnego oraz wskanik przepywu.
E. J. Bowman (Birmingham) Limited
Chester Street, Birmingham, B6 4AP, UK
Telephone: +44 (0) 121 359 5401 Facsimile: +44 (0) 121 359 7495
E-mail: [email protected] Web Address: www.ejbowman.co.uk
LONDON
BIRMINGHAM
City Centre
& M5
K