67% found this document useful (9 votes)
11K views2 pages

Wind Load Calculations .Xls Template

This document provides load calculations for a building with a main frame. It includes the building dimensions and specifications. It then calculates the dead load, collateral load, live load, and wind load based on the given specifications. Wind load diagrams are also provided showing the load distributions for different wind directions and internal pressure coefficients. The maximum calculated wind load is -6.271 KN/m when the wind is across the ridge with a positive internal pressure coefficient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
67% found this document useful (9 votes)
11K views2 pages

Wind Load Calculations .Xls Template

This document provides load calculations for a building with a main frame. It includes the building dimensions and specifications. It then calculates the dead load, collateral load, live load, and wind load based on the given specifications. Wind load diagrams are also provided showing the load distributions for different wind directions and internal pressure coefficients. The maximum calculated wind load is -6.271 KN/m when the wind is across the ridge with a positive internal pressure coefficient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

LOAD CALCULATIONS

:
:
:
:

Job No.
Project
Clint
Description

Building Type

Length (o/o)
Width (o/o)
Width module
Bay spacing
Clear eave height
Max. eave height
Roof slope ()

=
=
=
=
=
=
=

82.00 m
40.50 m

Wt. of sheet & purline


Dead Load (DL)

=
=

15.00 Kg/m
1.05 KN/m

Collateral Load on Rafter

=
=

0.00 Kg/m
0.00 KN/m

Live load/unit area, roof


Live Load (LL)

=
=

75.00 Kg/m
5.25 KN/m

Basic wind speed (Vb)


Design wind speed (Vz)
where,

=
39 m/s
= Vbxk1xk2xk3

7.00
7.00
8.00
5.71

Rev. No.
Date
Designed by
Checked by

LOADS APPLIED ON THE MAIN FRAME-1

:
:
:
:

R0
26/08/2014

m
m
m

DEAD LOAD (DL)

COLLATERAL LOAD
Other Collateral Load

=
=

0.00 Kg/m
0.00 KN/m

LIVE LOAD (LL)

WIND LOAD (WL)

k1 = probability factor (risk coefficient)


=
1
k2 = terrain, height and structure size factor
=
0.93
k3 = topography factor
=
1
Vz =
36.27 m/s
Design wind pressure (pz)

=
pz =

Terrain Category
2

Class
B

0.6xVz
0.789 KN/m
PRESURE COEFFICIENTS:~

Encloser condition of the building = Enclosed


Internal pressure coeff.(Cpi) =
0.20
h/w =
0.20
= h/w<=1/2
l/w =
2.02
= 3/2<=l/w<4
External pressure coeff.(Cpe) :
Wind Angle
()
0 degree
90 degree

Table 4
Coeff. For Wall
Left
Right
0.70
-0.25
-0.50
-0.50

Table 5
Coeff. For Roof
Left
Right
-0.9350
-0.40
-0.80
-0.80

WIND LOAD DIAGRAMS:~


Wind Across the Ridge (With -Ve Cpi)
-0.74
-4.06 KN/m
-0.20

KN/m
4.97
0.90

Wind Across the Ridge (With +Ve Cpi)


-1.14
-6.271 KN/m
-0.60

-1.11KN/m

KN/m
-0.28
-0.05

KN/m
2.76
0.50

Wind Parallel to Ridge(With +Ve Cpi)


-1.00
-5.53 KN/m
-1.00

KN/m
-2.49
-0.45

-5.53 KN/m

KN/m
-3.87
-0.70

KN/m
-3.87
-0.70

Wind Parallel to Ridge(With -Ve Cpi)


-0.60
-3.32 KN/m
-0.60

KN/m
-1.66
-0.30

KN/m
-3.32

-3.32 KN/m

KN/m
0.00
-0.30
Note:
1) Values within the circles are the UDL

2) -Ve value means, load applied


away from structure.

You might also like