Adss Cable
Adss Cable
BK
Description:
Up to 72 optical fibres in jelly-filled loose tubes, laid up around a central non-metallic
strength member, water blocked, aramid yarn reinforced, and polyethylene sheathed.
Surface printing includes sequential length marking at one-metre intervals.
Applicable Specifications:
AS/ACIF S-008, AS 1049, AS3080, IEC 60793 and IEC 60794
Applications:
A dry water-blocked, loose tube cable originally developed from a military lightweight-
rugged-deployable (LRD) field cable, it is now principally used for short span aerial
installations - typically on roadside power distribution poles. It is suitable for spans
typically up to 250 m - or more depending upon installation conditions (see examples at
end). Being totally non-metallic it is ideal for applications in close proximity to high-voltage
power distribution lines, for which it has become a standard.
This product is also suited to single point suspension applications such as down mine
shafts or any application where the product has to support either a higher load than
conventional terrestrial cable or a permanent or varying tensile load, applied through the
outer sheath. Standard pole-mounting hardware is readily available for this product.
Contact Optimal for assistance with sag-tension calculations or other application support.
Physical Characteristics
Tube Diameter: 2.8 mm
Nominal cable Diameter: 12.6 mm
Nominal weight: 125 kg/km
Max Allowable load: 7.7 kN
Zero fibre strain limit 1.0 %
Max Crush Resistance 4 kN/100 mm
Min bending radius 20xOD mm (Under load), 10xOD mm (off load)
Effective Modulus 12 GPa
Effective area 87 mm
CLTE 7.4 x10
-6
/C
MCBL 27 kN
Stringing Example Conditions
units EDS Severe 1 Severe 2 Severe 3
Temp C 15 -10 -30 +5mm ice 0
Wind m/s (km/hr) 0 42 (150) 27 (100) 56 (200)
Span m 100/200/300 200 250 100
Sag m 1/4/9 10 (0.74) 12.8 (3.8*) 4.6 (0.2*)
Tension kN 1.52 7.9 8.1 7.7
Cable Strain % 0.14 0.7 0.71 0.68
* vertical component
0pl|ca| l|ore
Arar|d Per|prera| 3lrerglr E|ererl
Vo|slure-Res|slarl Je||y-F|||ed
Loose Tuoe
Cerlra| 3lrerglr E|ererl
waler o|oc|ed core
0uler Po|yel ry|ere 3realr
** Represents any fibre code, L0 = sm G652.d (LWP), 1C = sm G652.d ZWP, 62 = 62.5 um OM1, 50 = 50 um OM2, 53 = 50
um OM3, 15 = SM G655 NZDS, 1F = G657.a ZWP HiFlex
This datasheet is provided for guidance only and is subject to change without notice. Please ensure you have the most up to
date information where parameters in this document are considered critical for your particular application.
Applicable Specifications
AS/ACIF S-008
AS 1049
AS3080
IEC 60793
IEC 60794
Physical Characteristics
TUBE DIAMETER 2.8 mm
NOMINAL CABLE
DIAMETER
12.6 mm
NOMINAL WEIGHT 125 kg/km
MAX. ALLOWABLE LOAD 7.7 kN
ZERO FIBRE STRAIN LIMIT 1.0 percent
MAX. CRUSH RESISTANCE 4 kN/100 mm
MIN. BENDING RADIUS
20 x OD mm (Under load)
10 x OD mm (off load)
EFFECTIVE MODULUS 12 GPa
EFFECTIVE AREA 87 mm
CLTE 7.4 x10-6/C
MCBL 27 kN
Stringing Example
PARAMETER UNITS
CONDITIONS
EDS SEVERE 1 SEVERE 2 SEVERE 3
TEMPERATURE C 15 -10 -30 +5 mm ice 0
WIND m/s (km/hr) 0 42 (150) 27 (100) 56 (200)
SPAN m 100/200/300 200 250 100
SAG m 1/4/9 10 (0.74) 12.8 (3.8*) 4.6 (0.2*)
TENSION kN 1.52 7.9 8.1 7.7
CABLE STRAIN % 0.14 0.7 0.71 0.68
AFL markets this product in Australia exclusively.